This document provides information for the INLINE™ 6 Data Link Adapter Kit, Part Number 2892092, and the
associated cables to connect a personal computer to the data link adapter. The INLINE™ 6 data link adapter is
designed for use with the SAE J1708 and J1939 standard protocols. The INLINE™ 6 data link adapter is used
with software applications such as INSITE™ Electronic Service Tool 7.5 and later versions. The INLINE™ 6
supports all Cummins Inc. electronic engines.
Note : A fully populated USB cable, Part Number 2892176 , or DB9F-DB9M, serial cable, Part
Number 4918418, must be used.
Connect the DB9F-DB9M serial cable, Part Number 4918418, or the USB cable, Part Number 2892176 to the
RS-232 serial port or the USB port of the computer and to the INLINE™ 6 data link adapter, Part Number
2892093.
https://quickserve.cummins.com/qs3/pubsys2/xml/en/sti/3400419.html?q=2892176 2/4
20/11/2019 INLINE™ 6 Data Link Adapter Kit
The INLINE™ 6 data link adapter requires +8-VDC to +50-VDC at 250mA that can be supplied through the
OEM connector or by a separate power source.
Connect the appropriate data link cable to the INLINE™ 6 data link adapter, Part Number 2892093.
With the data link cable connected to the INLINE™ 6 data link adapter, connect the other end of the data link
cable to the vehicle cab or engine compartment data link connector.
Launch the electronic service tool application software.
The following are the INLINE™ 6 Adapter Indicator Lamp Functions:
Power Lamp
When the power lamp is lighted green continuously, this means DC power is being supplied to the adapter
at the proper voltage level. The INLINE™ 6 adapter requires +8-VDC to +50-VDC at 250 mA that can be
supplied through the OEM connector or by a separate power source.
When the power lamp is lighted red continuously, this means that either the INLINE™ 6 adapter is
receiving a low power supply voltage (less than 8-VDC) or is only receiving power from the USB port.
When the power lamp is off, this means that the INLINE™ 6 is receiving no power.
CAN 1 Port Lamp
A CAN 1 red flashing lamp indicates that the INLINE™ 6 adapter is physically connected to a CAN data
link. However, it is not communicating with an ECM on the CAN data link. A CAN 1 green flashing lamp
indicates that the INLINE™ 6 adapter is communicating with an ECM on the CAN data link.
CAN 2 Port Lamp
A CAN 2 red flashing lamp indicates that the INLINE™ 6 adapter is physically connected to a CAN data
link. However, it is not communicating with an ECM on the CAN data link. A CAN 2 green flashing lamp
indicates that the INLINE™ 6 adapter is communicating with an ECM on the CAN data link.
J1708 Port Lamp
A J1708 red flashing lamp indicates that the INLINE™ 6 adapter is physically connected to a J1708 data
link. However, it is not communicating with an ECM on the J1708 data link. A J1708 green flashing lamp
indicates that the INLINE™ 6 adapter is communicating with an ECM on the J1708 data link.
RS‐232 Port Lamp
https://quickserve.cummins.com/qs3/pubsys2/xml/en/sti/3400419.html?q=2892176 3/4
20/11/2019 INLINE™ 6 Data Link Adapter Kit
An RS-232 green flashing lamp indicates that the INLINE™ 6 adapter is connected to an active RS-232
port and exchanging communications. An RS-232 lamp in the OFF state indicates that the INLINE™ 6
adapter is not communicating over the RS-232 port.
USB Port Lamp
A USB green flashing lamp indicates that the INLINE™ 6 adapter is connected to an active USB port and
is exchanging communications. A USB lamp in the OFF state indicates that the INLINE™ 6 adapter is not
communicating over the USB port.