100% found this document useful (2 votes)
3K views20 pages

List of Spare Parts Tools

This document provides a schedule and item list for a Qatar power transmission system expansion project. It includes quantities and descriptions of equipment for 400kV, 132kV, and 66kV switchgear, including circuit breakers, busbars, current and voltage transformers, and disconnectors. The schedule contains detailed parts lists and specifications for switchgear components to be provided over a 1 year period as part of Phase 12 of the transmission system expansion.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (2 votes)
3K views20 pages

List of Spare Parts Tools

This document provides a schedule and item list for a Qatar power transmission system expansion project. It includes quantities and descriptions of equipment for 400kV, 132kV, and 66kV switchgear, including circuit breakers, busbars, current and voltage transformers, and disconnectors. The schedule contains detailed parts lists and specifications for switchgear components to be provided over a 1 year period as part of Phase 12 of the transmission system expansion.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 20

   

    SCHEDULE
4.3
REV. 2
  Date 
QATAR POWER TRANSMISSION SYSTEM EXPANSION -
Signature 
PHASE 12 - SUBSTATIONS 
ITEM  DESCRIPTION  QTY 
A.1 400 kV Switchgear (for each type) NA
A.2 132 kV Switchgear (for each type)
1 Circuit Breakers
Pressure Monitor 2
Pressure Switch 2
Pressure gauge 2
Pressure relief device 2
Absorbers (cartridges or loose chemicals as applicable) 5%
Arcing contact 0
Moving contact 0
Fixed contact 0
Complete set of gaskets
1 set
(shall be delivered at the end of warranty period)
Blast nozzle 0
Supporting nozzle 0
Supporting insulator with barrier 2
Heater 0
Hygrostat 0
Fuses 0
Fuse Bases 0
MCB's 0
Indication lamps 0
Indication lamp holders 0
Indication lamp covers 0
Door switch 0
Complete Circuit Breaker with operating mechanism 1
Required quantity
Special lubricants for 1 years
operation
Circuit Breaker Operating Mechanism
2
(each type/ rating)
Motor 2
Dashpot 2
Dashpot repair kit 0
Closing coil 2
Tripping coil 2
Resistors 0
 
 
 
   
    SCHEDULE
4.3
REV. 2
  Date 
QATAR POWER TRANSMISSION SYSTEM EXPANSION - Signature
PHASE 12 - SUBSTATIONS 

Limit switches (Drive mechanism) 2 Each type


Local/remote selector switch 0
Close/open selector switch 0
Auxiliary relays/timer relays of each type 2 Each type
Overhaul kit (for complete overhauling of mechanism) 1
Operating mechanism (complete unit) 1
Required quantity
Special lubricants for 1 years
operation
Wiring plug and socket set 1
Disconnector and Earth Switches
3
(Each type/rating)
Motor 2
Moving contact 2
Fixed contact 0
Limit switches 0
Pressure monitor 2
Pressure relief device 2
Complete set of gaskets (shall be delivered at the end of
1 set
warranty period)
Complete Isolator/Earth switch. 1 Each
Required quantity
Special lubricants for 1 years
operation
4 Busbars
Support Insulator 2
Support Insulator with barrier 2
Complete set of gaskets (shall be delivered at the end of
1 set
warranty period)
1 pc.
Current transformers
Each used in GIS
1 pc.
Voltage transformers
Each used in GIS
Bus bar pieces with bolts one set for onebay
Sliding contacts 2 sets

 
 
 
   
    SCHEDULE
4.3
REV. 2
  Date 
QATAR POWER TRANSMISSION SYSTEM EXPANSION -
Signature 
PHASE 12 - SUBSTATIONS 
ITEM  DESCRIPTION  QTY 
TOTAL FOR ITEM A.2
A.3 66 kV Switchgear (for each type)
1 Circuit Breakers
Pressure Monitor 2
Pressure Switch 2
Pressure gauge 2
Pressure relief device 2
Absorbers (cartridges or loose chemicals as applicable) 5%
Arcing contact 0
Moving contact 0
Fixed contact 0
Complete set of gaskets
1 set
(shall be delivered at the end of warranty period)
Blast nozzle 0
Supporting nozzle 0
Supporting insulator with barrier 2
Heater 0
Hygrostat 0
Fuses 0
Fuse Bases 0
MCB's 0
Indication lamps 0
Indication lamp holders 0
Indication lamp covers 0
Door switch 0
Complete Pole of Circuit Breaker 1
Required quantity
Special lubricants for 1 years
operation
Circuit Breaker Operating Mechanism
2
(each type/ rating)
Motor 2
Dashpot 2
Dashpot repair kit 0

 
 
 
   
    SCHEDULE
4.3
REV. 2
  Date 
QATAR POWER TRANSMISSION SYSTEM EXPANSION -
Signature 
PHASE 12 - SUBSTATIONS 
ITEM  DESCRIPTION  QTY 
Closing coil 2
Tripping coil 2
Resistors 0
Limit switches (Drive mechanism) 2 Each type
Local/remote selector switch 0
Close/open selector switch 0
Auxiliary relays/timer relays of each type 2 Each type
Overhaul kit (for complete overhauling of mechanism) 1
Operating mechanism (complete unit) 1
Required quantity
Special lubricants for 1 years
operation
Wiring plug and socket set 1
Disconnector and Earth Switches
3
(Each type/rating)
Motor 2
Moving contact 2
Fixed contact 0
Limit switches 0
Pressure monitor 2
Pressure relief device 2
Complete set of gaskets (shall be delivered at the end of
1 set
warranty period)
Complete Isolator/Earth switch. 1 Each
Required quantity
Special lubricants for 1 years
operation
4 Busbars
Support Insulator 2
Support Insulator with barrier 2

 
 
 
  SCHEDULE
    4.3
REV. 2 

  Date 
QATAR POWER TRANSMISSION SYSTEM EXPANSION -
Signature 
PHASE 12 - SUBSTATIONS 
ITEM  DESCRIPTION  QTY 
Complete set of gaskets (shall be delivered at the end of
1 set
warranty period)
1 pc.
Current transformers
Each used in GIS
1 pc.
Voltage transformers
Each used in GIS
Bus bar pieces with bolts one set for onebay
Sliding contacts 2 sets
TOTAL FOR ITEM A.3
A.4 33 kV Switchgear (for each type)
1 Circuit Breakers
Pressure Monitor 2
Pressure Switch 2
Pressure gauge 2
Pressure relief device 2
Absorbers (cartridges or loose chemicals as applicable) 5%
Arcing contact 0
Moving contact 0
Fixed contact 0
Complete set of gaskets
1 set
(shall be delivered at the end of warranty period)
Blast nozzle 0
Supporting nozzle 0
Supporting insulator with barrier 2
Heater 0
Hygrostat 0
Fuses 0
Fuse Bases 0
MCB's 0
Indication lamps 0
Indication lamp holders 0
Indication lamp covers 0
Door switch 0
Complete Pole of Circuit Breaker 1
 

 
 
 
   
    SCHEDULE
4.3
REV. 2
  Date 
QATAR POWER TRANSMISSION SYSTEM EXPANSION -
Signature 
PHASE 12 - SUBSTATIONS 
ITEM  DESCRIPTION  QTY 
Required quantity
Special lubricants for 1 years
operation
Circuit Breaker Operating Mechanism
2
(each type/ rating)
Motor 2
Dashpot 2
Dashpot repair kit 0
Closing coil 2
Tripping coil 2
Resistors 0
Limit switches (Drive mechanism) 2 Each type
Local/remote selector switch 0
Close/open selector switch 0
Auxiliary relays/timer relays of each type 2 Each type
Overhaul kit (for complete overhauling of mechanism) 1
Operating mechanism (complete unit) 1
Required quantity
Special lubricants for 1 year’s
operation
Wiring plug and socket set 1
Disconnector and Earth Switches
3
(Each type/rating)
Motor 2
Moving contact 2
Fixed contact 0
Limit switches 0
Pressure monitor 2
Pressure relief device 2
Complete set of gaskets (shall be delivered at the end of
1 set
warranty period)
Complete Isolator/Earth switch. 1 Each
Required quantity
Special lubricants for 1 year’s
operation
4 Busbars
Support Insulator 2
 
 
 
 

   
    SCHEDULE
4.3
REV. 2
  Date 
QATAR POWER TRANSMISSION SYSTEM EXPANSION -
Signature 
PHASE 12 - SUBSTATIONS 
ITEM  DESCRIPTION  QTY 
Complete set of gaskets (shall be delivered at the end of
1 set
warranty period)
1 pc.
Current transformers
Each used in GIS
1 pc.
Voltage transformers
Each used in GIS
one set for one
Bus bar pieces with bolts
bay
Sliding contacts 2 sets
TOTAL FOR ITEM A.4

B POWER TRANSFORMERS (for each typical transformer)


B.1 500MVA 400/132kV Transformers NA
B.2 220/66kV Transformers NA
B.3 160 MVA, 132/66kV Transformers NA
B.4 40MVA 132/11kV Transformers
Magnetic oil level gauge 1
Automatic repetitive type of breather 1
Buchholz relay 1
Oil temperature indicator 1
Winding temperature indicator - electronic and analogue 1
Pressure relief device 1
Cooling fan motors with blades - complete assembly 2
Local/remote switch (for fan control) 1
On/Off Switch (for fan control) 1
25%
Contactors
(min 2)
Heater 0
Fuses 0
Fuse base 0
HV bushing 1
 

 
 
 
 
   
    SCHEDULE
4.3
REV. 2
  Date 
QATAR POWER TRANSMISSION SYSTEM EXPANSION -
Signature 
PHASE 12 - SUBSTATIONS 
ITEM  DESCRIPTION  QTY 
LV Bushing 1
Note: The spare bushings should be packed for long term
storage at factory before delivery.
Neutral bushing 1
Complete set of gaskets 1 set
On-load Tap Changer 40 MVA, 66/11kV Transformers
Motor 1
Fuses (for motor supply) 5%
Contactors/timers (each type) 10%
MCB's 10%
Heater 0
Hygrostat 0
Thermostat 0
Limit switches (each type) 10%
Local/remote switch (for tap change operation) 10%
Tap raise/lower switch 10%
Protective relay 2
Complete set of gaskets 1
Diverter switch (complete unit – packed in a suitable container) 1
Pressure relief device 1
Expansion diaphragm packed in suitable sealed containers 1
TOTAL FOR ITEM B.4
B.5 40MVA 66/11kV Transformers
Magnetic oil level gauge 1
Automatic repetitive type of breather 1
Buchholz relay 1
Oil temperature indicator 1
Winding temperature indicator - electronic and analogue 1
Pressure relief device 1
Cooling fan motors with blades - complete assembly 2
Local/remote switch (for fan control) 1
On/Off Switch (for fan control) 1
25%
Contactors
(min 2)
 

 
 
 
 
   
    SCHEDULE
4.3
REV. 2
  Date 
QATAR POWER TRANSMISSION SYSTEM EXPANSION -
Signature 
PHASE 12 - SUBSTATIONS 
ITEM  DESCRIPTION  QTY 
Heater 0
Fuses 0
Fuse base 0
HV bushing 1
LV Bushing 1
Note: The spare bushings should be packed for long term
storage at factory before delivery.
Neutral bushing 1
Complete set of gaskets 1 set
On-load Tap Changer 40 MVA, 66/11kV Transformers
Motor 1
Fuses (for motor supply) 5%
Contactors/timers (each type) 10%
MCB's 10%
Heater 0
Hygrostat 0
Thermostat 0
Limit switches (each type) 10%
Local/remote switch (for tap change operation) 10%
Tap raise/lower switch 10%
Protective relay 2
Complete set of gaskets 1
Diverter switch (complete unit – packed in a suitable container) 1
Pressure relief device 1
Expansion diaphragm packed in suitable sealed containers 1
TOTAL FOR ITEM B.5
B.6 100MVA 132/33kV Transformers
Oil pump for OFAF transformer 3
Magnetic oil level gauge 1
Automatic repetitive type of breather 1
Buchholz relay 1
Oil temperature indicator 1
Winding temperature indicator - electronic and analogue 1
Pressure relief device 1
 

 
 
 
 
   
    SCHEDULE
4.3
REV. 2
  Date 
QATAR POWER TRANSMISSION SYSTEM EXPANSION -
Signature 
PHASE 12 - SUBSTATIONS 
ITEM  DESCRIPTION  QTY 
Cooling fan motors with blades - complete assembly 1
Local/remote switch (for fan control) 1
On/Off Switch (for fan control) 1
Contactors 10% each used
Heater 0
Fuses 10%
Fuse base 5%
HV bushing 1 pc.
LV Bushing 1 pc.
Note: The spare bushings should be packed for long term
storage at factory before delivery.
Neutral bushing 1 pc.
Stabilizing winding bushing packed for long storage 1
Complete set of gaskets 1 set
1.1 On-load Tap Changer 100MVA, 132/33kV Transformers
Motor 0%
Fuses (for motor supply) 1
Contactors/timers (each type) 2
MCB's 10%
Heater 0
Hygrostat 0
Thermostat 0
Limit switches (each type) 0
Local/remote switch (for tap change operation) 0
Tap raise/lower switch 2
Protective relay 2
Complete set of gaskets 1set
Diverter switch (complete unit – packed in a suitable container) 1
Pressure relief device 1
Expansion diaphragm packed in suitable sealed containers 1
TOTAL FOR ITEM B.6
B.7 AUXILIARY TRANSFROMERS
Magnetic oil level gauge 1
Automatic repetitive type of breather 1
Buchholz relay 1
Oil temperature indicator 1

 
 
 
 

   
    SCHEDULE
4.3
REV. 2
  Date 
QATAR POWER TRANSMISSION SYSTEM EXPANSION -
Signature 
PHASE 12 - SUBSTATIONS 
ITEM  DESCRIPTION  QTY 
Winding temperature indicator - electronic and analogue 1
Pressure relief device 1
Contactors 10%
Heater 0
Fuses 10%
Fuse base 5%
HV bushing 1
LV Bushing 1
Note: The spare bushings should be packed for long term
storage at factory before delivery.
TOTAL FOR ITEM B.7
C 400kV Shunt Reactors NA
D. 11 kV Switchgear (for each type)
11kV Vacuum Circuit Breaker (withdrawable type):
- 630 A packed for storage 2
- 2500A packed for storage 1
1 set per each
Joint shrouds
type of panel
Heater 0
Thermostat 0
Local/remote selector switch 1
On/Off switch 1
MCB's 2 Each type
Motor 2
Fuses 0
Fuse bases 0
Indication lamps 1
Indication lamp holders 5%
Limit switches 3 each type
Contactors 10%
Auxiliary relays/timer relays of each type 10%
HV fuses for VT 3
Set of contact fingers 2 set
 

 
 
 
 

   
    SCHEDULE
4.3
REV. 2
  Date 
QATAR POWER TRANSMISSION SYSTEM EXPANSION -
Signature 
PHASE 12 - SUBSTATIONS 
ITEM  DESCRIPTION  QTY 
Closing coil 2
Tripping coil 2
Resistors 0
Earthing blades 1 set
Busbar support insulators 10%
Vacuum bottles suitably packed and sealed 3 pcs of each type
Circuit Breaker Operating Mechanism of each type. 1 Each
Bus bar supporting insulator (If applicable) 4
One set for each
Bus bar pieces with bolts
type of panel
TOTAL FOR ITEM D

E Protective Relays
Protective relays
1
(each type) (Contractor to give details)
Busbar protection relays including bus checking relay
1
(each type) (Contractor to give details)
Auxiliary & tripping relays
1
(each type) (Contractor to give details)
Fuses each type/rating 10%
Fuse bases 10%
MCB's 10%
Indication lamps 1
TOTAL FOR ITEM E

F Various Equipment
Batteries (110 V & 48 V)
Spare cells battery (each type) 2
Spare electrolyte (in solid form) 10%
Battery chargers
Thyristors & Diodes (each type) 1
Fuses (each type and rating) 1
Measuring shunts and instrument (each type) 1

 
 
 
   
    SCHEDULE
4.3
REV. 2
  Date 
QATAR POWER TRANSMISSION SYSTEM EXPANSION -
Signature 
PHASE 12 - SUBSTATIONS 
ITEM  DESCRIPTION  QTY 
Control switches (each type) 1
Battery earth fault relay 2
Indication lamps 1
Control cards (each type) 2
Regulating cards (each type) 2
Signaling cards (each type) 2
Changeover switch (each type) 2
Isolating switch (each type) 2
Recommended parts 1 set
LVAC Board
Circuit breakers (incomer) 1
Indication lamps 1
Relay (each type) 1
Limit switches (each type) 1
Contactors (each type) 1 set
Control switches 1 set
HVAC systems as specified and proposed by the contractor 1 set
Filters 1 set
Fan belt drivers 1 set
FIRE ALARM SYSTEM
Addressable Optical Smoke Detector w/ base 5%
Addressable rate of rise heat detector w/ base 5%
Addressable rate of rise heat detector w/ base (explosion
5%
proof)
Analogue Addressable Loop Module 5%
Relay module for fire alarm control panel 5%
Monitor module 5%
Control module 5%
Addressable smoke duct detector with base 5%
Filter cartridge for air duct detector 5%
Flasher red color (conventional) 5%
Addressable manual call point w/ isolator and spare plastic
5%
panel
Addressable manual call point (explosion proof) 5%
Sounder / Bell 5%
Sounder / Bell weather proof w/ base 5%
 
 
 
 
   
    SCHEDULE
4.3
REV. 2
  Date 
QATAR POWER TRANSMISSION SYSTEM EXPANSION -
Signature 
PHASE 12 - SUBSTATIONS 
ITEM  DESCRIPTION  QTY 
Set of Fuses 5%
Spare set of PCB's for the Main FACP consisting of the following: Main 1 Set for each type
CPU Card, Power Supply Unit, Display Card & Network Card of Panel used.
Spare set of PCB's for the Repeater Panel consisting of the following: Main 1 Set for each type
CPU Card, Display Card & Network Card of Panel used.
FIRE EXTINGUISHER
CO2 Fire Extinguisher 5%
Dry Powder Fire Extinguisher 5%
FM200 SYSTEM
Discharge Pressure Switch 5%
Smoke Detector with Base 5%
Abort Switch 5%
Manual Release Switch with back box 5%
Fire Alarm Bell 5%
Horn Strobe 5%
Flasher 5%
Relay Module 5%
Solenoid Valve 5%
Spare set of PCBs’ for the FM200 Panel consisting of the following: Main 1 Set for each type
CPU c/w Display Card of Panel used.
DELUGE SYSTEM
Deluge Valve Parts only (Diaphragm, Flat Washer, Hex Bolt, 1 Set for each
Hex Nut) deluge valve size
Fixed Temperature Sprinkler, 79°C 5%
- 6 pcs for less
Fixed Temperature Sprinkler, 93°C than 300
sprinklers installed
- 12 pcs for more
than 300
sprinklers installed
Glycerin Pressure Gauge 5%
Suction Pressure Gauge 5%
Drain Valve, 1" 5%
Water Motor Alarm Gong 5%
Pressure Relief Valve 1" 5%
 

 
 
 
   
    SCHEDULE
4.3
REV. 2
  Date 
QATAR POWER TRANSMISSION SYSTEM EXPANSION -
Signature 
PHASE 12 - SUBSTATIONS 
ITEM  DESCRIPTION  QTY 
  Gasket (each sizes) 5%
  Tamper Switch 1
  Flow Switch 1
  Y-Strainer Mesh 1
  Pressure Switch 1
  Sensing Line Check Valve 1
FIRE PUMP SET
Shaft Sleeve 2
O-ring & Gasket 2
Wear Ring 2
Gland Packing 1 set
Bearing, Driven End and Non-Driven End 2
Casing Gasket 1
Oil Filter 1
Fuel Filter 1
Air Filter 1
ELECTRIC & DIESEL FIRE PUMP CONTROLLER
Pressure Transducer 1
Fuse Links 2
Pressure Board 1
JOCKEY PUMP CONTROLLER
Pilot Bulb 2
Overload Relay 1
Auxiliary Relay 1
Pressure Switch 1
Small power & Lighting As per specification requirement. (as
Lot
specified and proposed by the contractor)
UPS
spares including 2 each replaceable unit lot
SECURITY MANAGEMENT SYSTEMS
Outdoor - PTZ (1.3MPX 18 X Pan/Tilt/Zoom Camera) 2
Outdoor Fixed Cameras (3 MPX Full HD Box Camera
2
ONVIF/PSIA)
Indoor Dome Camera (3 MPX Full HD Box Camera
2
ONVIF/PSIA)
 

 
 
 
   
    SCHEDULE
4.3
REV. 2
  Date 
QATAR POWER TRANSMISSION SYSTEM EXPANSION -
Signature 
PHASE 12 - SUBSTATIONS 
ITEM  DESCRIPTION  QTY 
  16ch Network Video Recorder (NVR) 1
  Digital Keyboard for P/T/Z Camera 1
  Access Control System - Controller 1
  Card Readers 4
  Emergency Door Release Buttons 4
  GSM based Guard Touring System (GPRS / GSM Real Time
2
Guard Tour System) Readers
TOTAL FOR ITEM F

G SCS spares
Industrial Rack Computer Hard disk 2 Nos.
FO ports used in Rugged COM Switches (5% or min. 2 of each
Lot
type)
Ethernet ports used in Rugged COM Switches (5% or min. 2 of
Lot
each type)
KVM Switch/Extender (1Set per lot, if applicable) Lot
Industrial Rack Computer SMPS Card 1 No.
SCS Rack PC &Panel Air Filter (5Nos. Of each type) Lot
SCS Panel Fans (2 Nos. of Each Type) 2 sets
BCU (2 of each type) Lot
LAN spares (2 of each type replaceable units) Lot
Switch (2 of each type) Lot
Firewall/router (1 of each type) Lot
Fully equipped Computer (1 of each type) Lot
Monitor (1 of each type) Lot
GPS clock 2 sets
Prefabricated Ethernet - copper cables with rugged RJ45
Lot
connectors (5% or min. 2 of each length)
Prefabricated FO cables (5% or min. 2 of each length and each
Lot
connector type)
 

 
 
 
   
    SCHEDULE
4.3
REV. 2
  Date 
QATAR POWER TRANSMISSION SYSTEM EXPANSION -
Signature 
PHASE 12 - SUBSTATIONS 
ITEM  DESCRIPTION  QTY 
TOTAL FOR ITEM G

H.1 PD Monitoring System NA


H.2 TR / SR Monitoring System
Sensors, of each type 5%
5%
Field terminal / control unit
min 1
Control unit at the field (2 of each replaceable units) Lot
10%
Set of FO cables (maximum length)
min 1
LAN spares (2 of each type replaceable units) Lot
Central control unit spares (2 of each replaceable units) Lot
Min. 1 or 5%
OLTC Monitoring unit and associated spares
whichever is more
Min. 1 or 5%
PD Monitoring unit and associated spares
whichever is more
Set of field wiring cables (Max. length each type.) 5%
TMS Server and Central control unit spares.
Fuses each type 10%
Relays/Timer each type 5%
Hygrostat 5%
Thermostat 5%
Heater 5%
Door Cabinet light 5%
Power Supply unit each type 5%
Watch dog terminal and control unit 5%
Communication module 5%
I/O Modules of each type 5%
Transducers and similar components 5%
Control unit and PCB Assemblies 5%
Over voltage/Over current/Surge protector 5%
DGA Monitoring module spares
Min. 2 or 5%
Oil supply/return assembly, Valve regulator & bleed fixtures etc.
whichever is more
All replaceable components (cards, hot zone cylinders etc.) each type 1 Each
Lamp & LED's 10%
Communication module 5%
I/O Modules of each type 5%
Fuses each type 10%

 
 
 
 

   
    SCHEDULE
4.3
REV. 2
  Date 
QATAR POWER TRANSMISSION SYSTEM EXPANSION -
Signature 
PHASE 12 - SUBSTATIONS 
ITEM  DESCRIPTION  QTY 
Fan 5%
Heater 5%
Min. 1 or 5%
Local display unit
whichever is more
Special tools (Calibration kit etc.) each type 1 Each
H.3 Integrated WS
Computer spars (2 of each replaceable units) Lot
Firewall 1 no
 

 
 
 
 
   
    SCHEDULE
4.4
REV. 2
  Date 
QATAR POWER TRANSMISSION SYSTEM EXPANSION -
Signature 
PHASE 12 - SUBSTATIONS 
ITEM  DESCRIPTION  QTY 
A1 Gas Insulated Switchgear
HV Test bushing with adaptor and required accessories for 400kV
NA
GIS
Complete set of special tools for maintenance and complete
NA
overhauling of 400kV GIS (Contractor to provide details)
Complete set of special tools for maintenance and complete
1 set
overhauling of 132kV GIS (Contractor to provide details)
HV Test bushing with adaptor and required accessories for 132kV
1 set
GIS
HV Test bushing with adaptor and required accessories for 66kV
1 set
GIS
Complete set of special tools for maintenance and complete
1 set
overhauling of 66kV GIS (Contractor to provide details)
HV Test bushing with adaptor and required accessories for 33kV
1 set
GIS
Complete set of special tools for maintenance and complete
1 set
overhauling of 33kV GIS (Contractor to provide details)
Mobile trolley mounted gas evacuation and refilling cart with
suitable hoses, adaptor and connected coupling. 5 Set
One (1) unit for each GIS room
A set of instruments consisting of:
Thermometer - 1 no.
Hygrometer - 1 no.
5 Set
Electronic weighing scale to measure wt. of SF6 gas cylinder - 1
no.
One (1) set for each GIS room
A2 11kV Switchgear (for each substation)
11kV Test plugs:
- Incomer bays 1 set
- Feeder bays 1 set
Safety step ladder with roll castor and lock (adequate height for 1 No.
easy operation and maintenance work)
Set of special tools for maintenance and complete overhauling 1 set
(as per recommendations of manufacturer) (Contractor to give
details)
B1 500 MVA 400/132kV Transformer NA

 
 
 
SCHEDULE
4.4
REV. 2
Date
QATAR POWER TRANSMISSION SYSTEM EXPANSION - PHASE 12 -
SUBSTATIONS Signature

ITEM DESCRIPTION QTY


Lifting device for diverter switch 1 pc.
Slings for lifting/handling core and windings 1 set
Blanking plates for radiator and valve connections 1 set
B2 80 MVAR 400kV Reactor NA
Lifting device for diverter switch 1 pc.
Slings for lifting/handling core and windings 1 set
Blanking plates for radiator and valve connections 1 set
B3 200 MVA 220/66kV Transformer NA
Lifting device for diverter switch 1 pc.
Slings for lifting/handling core and windings 1 set
Blanking plates for radiator and valve connections 1 set
B4 40 MVA 132/11kV Transformer
Lifting device for diverter switch 1 pc.
Blanking plates for radiator and valve connections 1 set
B5 40 MVA 66/11kV Transformer
Lifting device for diverter switch 1 pc.
Blanking plates for radiator and valve connections 1 set
B6 100 MVA 132/33kV Transformer
Lifting device for diverter switch 1 pc.
Blanking plates for radiator and valve connections 1 set
C Substation Control System
Diagnostic Software Tools (as specified in Technical Schedules) 1 set
Tool for Opening of the Top Covers of Industrial Rack mounted 1 set
PC's.
IEC Protocol Simulator with Life Time License (Recommended 1 set
by System Provider).

D ONLINE MONITORING SYSTEM


Any special tool recommended by the supplier for Transformer 1 set
Monitoring System
Diagnostic Software Tools for Partial Discharges Monitoring NA
System
Hardware Filters (Low Pass & High Pass) 1 Nos

 
 
 