FCR Prima Ii

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4
At a glance
Powered by AI
The key takeaways are that Fujifilm has been pioneering digital radiography since 1983 and their newest product, FCR PRIMA II, offers enhanced processing capacity of up to 55 images per hour while maintaining easy operability and high functionality.

FCR PRIMA II offers a compact footprint, enhanced processing capacity up to 55 images per hour, and stable and optimized high-quality images through Fujifilm's Image Intelligence technology. It also has an all-in-one workstation.

Image Intelligence automatically enhances images by improving contrast and sharpness across the entire image without risk of losing details. It combines Fujifilm's experience in imaging with superior hardware and software to enhance images while isolating and suppressing noise.

FCR Solution

FCR PRIMA II

Enhanced Processing Capacity — leads to smoother operation

Compact
55
IPs hr.
footprint
Installed units

Achievement 90,000 FCR PRIMA

Since the launching of our first FCR product in 1983, we


CAPSULA X
have been striving to develop the FCR technology further
and to make available a wide range of products. PROFECT ONE

Our superb technology and diversified product lineup has VELOCITY T

gained recognition from medical institutions of all practices VELOCITY U

and to date over 90,000* digital imaging systems have XG-1

With the launch of the first FCR (Fuji Computed Radiography) been installed worldwide. * As of end of September 2011 1983 2000 2011
product in 1983, we have brought “DIGITAL” X-ray
diagnostics to the world of analog diagnostics. Since then,
our products have always been at the forefront of digital
imaging and have contributed to improving the efficiency of

Quality
diagnostic imaging and the quality of medical care. A new We have been able to achieve high imaging quality as a result of
stage in the history of X-ray diagnostics has been marked with our long years of research in the technology of medical imaging.
the announcement of our FCR PRIMA II. We are confident The proven high durability and high stability of our products are
proof of our high quality.
that this product will further enhance your diagnostic needs.

Unparalleled high quality Durability that we can be


proud of
Only a pioneer can achieve such a thing The FCR offers over 180 pre-set
Exposure Menus. They are optimized
to each body part and exposure 1/1 1/5 1/10
The FCR systems have proven to be
day-in and day-out reliable, thanks to
– Fujifilm’s digital imaging system
Exposure dose
techniques, and supply you with the the well-designed product features and
Automatic adjustment
best quality image without any extra the built-in redundancy that prevents
adjustment. Such excellence has been problems before they occur. In working
brought about by extensive joint efforts with the FCR, its proven durability will
and collaboration with experienced provide you with the maximum uptime
radiologists for over 25 years. for your medical facilities.

Originality
Image Intelligence™ from Fujifilm is an integration of
various digital image-processing technologies to
enhance the contrast and sharpness of the entire
image without any risk of losing the image details.
As such, Image Intelligence™ is the result of an ideal
combination of Fujifilm’s many years of experience in
imaging and its ability to create superior hardware and
software products.

MFP* Multi-Frequency Processing FNC Flexible Noise Control GPR Grid Pattern Removal
Enhances FCR images. All diagnostic Provides a non-grainy image by mainly Removes the stationary grid patterns
scopes will be enhanced except for noise. isolating and suppressing the noise for thus preventing Moiré from being
*Optional software the signal. generated resulting in easier diagnosis.
From digitalize to archive, this is Fujifilm’s seamless workflow

Digitalize R e a d Archive

Compact footprint, only 0.24m2 All-in-one workstation Various diagnostic functions Integrated management of image data
FCR PRIMA II is one of the most compact FCR PRIMA Console is a complete and patient information
and lightweight reader units on the market. image management workstation that Console You can register a maximum of 200,000
The required space is comparatively smaller is designed for simple and fast patient patient information on the PC. The registered
than other similar table-top systems and identification, image acquiring and patient information can then be speedily
can be installed in any open space. Another processing, as well as image viewing, Viewer Archive
retrieved and displayed by entering the
advantage of this unit is that you don’t need reprocessing, optimizing, and patient name and ID number. Patient
a darkroom any longer. archiving. information can also be retrieved from a
A magnified image Measurement function DICOM MWM server*. *Requires an optional software.

Enhanced IP Processability Quick display with simple operation


The new model FCR PRIMA II Easy to use menus that
Less storage space
FCR PRIMA
now offers enhanced guide your operation All images are stored in the HDD of the PC. DVD+RW DVD-RW
processability with speed of
up to 55 IPS/hr., almost double
29 IPs/hr.
from image taking to
diagnosis. You can
These high-quality images can be copied to
FCR PRIMA II a DVD or NAS (Network Attached Storage)
FCR PRIMA’s 29 IPS/hr., yet customize the user as backup. This digital system requires less
leaving the easy operability and NAS
high functionality intact. As a 55 IPs/hr.
interface according to
your preference such
Comparing archived images An annotated image
storage space than an analog imaging system.

result, the patient handling as adding shortcut FCR PRIMA Console is a multi-functional unit that has
time at clinics and hospitals is reduced significantly leading buttons or removing functions to: The PDI (Portable Data for Imaging) function
to smoother operation and increased patient turnover. unneeded ones. Just - change the magnification of an image
input the patient information and select the Exposure - display the studied images side-by-side By bundling the Simplified DICOM Doctor Patient
CD-R
Menu, then a suitable image processing condition will be - compare the latest image with the archived images Viewer Software with the patient
Stable and optimized images automatically applied and the adjusted image will be information onto CD-R or DVD-R,
DVD-R
- measure the length, angle, etc. of the image
Fujifilm’s Image Intelligence™ technology automatically enables displayed for diagnosis. - add annotation text, graphic symbols, and electronic images can be distributed to patients
stable and optimized high-quality images. markers to an image for viewing on their PCs.

Other features Other features Other features


Flexible reading in various sizes Limit of access to patient information for security Preset image processing for more effective diagnosis Can send images in JPEG format by e-mail
Repeated use of IP Uses a suitable monitor for medical image display Can print film through dry imager
FCR PRIMA II Specifications

Standard Components FCR PRIMA II Image Reader (Model: CR-IR 391RU)


AC power cord

Other System Components IP cassette type CC


FCR PRIMA Console, FCRView
Dry Imager: DRYPIX PRIMA, DRYPIX 2000, 4000, 7000, Plus

Supplies Imaging Plate ST-VI:


35 ✕ 43 cm (14”✕ 17”), 35 ✕ 35cm (14”✕ 14”), 10”✕ 12”, 8”✕ 10”,
24 ✕ 30 cm, 18 ✕ 24cm, 15 ✕ 30cm (Variation)
IP Cassette Type CC:
35 ✕ 43 cm (14”✕ 17”), 35 ✕ 35cm (14”✕ 14”), 10”✕ 12”, 8”✕ 10”,
24 ✕ 30 cm, 18 ✕ 24cm, 15 ✕ 30cm (Variation)

Time Required for IP Feed/Load Min. 66 sec.

Processing Capacity Up to 55 IPs /hr.

Reading Specification 10 pixels /mm

Time to Start on Display Min. 33 sec.

Time to Print on DRYPIX PRIMA Approx. 165 sec. in case of 35 ✕ 43cm

Number of Stacker 1

Network 10 Base T/100 Base TX

Dimensions (W ✕ D ✕ H) 600 ✕ 400 ✕ 780 mm (24”✕ 16”✕ 31”)

Weight 70 kg (155 lbs.)

Power Supply Conditions Single phase 50 -60 Hz


AC100- 240V ±10% 5 A (max)

Environmental Conditions Operating Conditions:


• Temperature: 15 -30 °C
• Humidity: 15 - 80%RH (No dew condensation)
• Atmospheric pressure: 750 -1060 hPa

This equipment is a Class 1 laser product (IEC60825-1).

Dimensions Unit: mm (in.) Imaging Plate


400 (16) 600 (24) ST-VI
35 ✕ 43 cm (14” ✕ 17”),
35 ✕ 35 cm (14” ✕ 14”),
10” ✕ 12”, 8” ✕ 10”,
24 ✕ 30 cm, 18 ✕ 24 cm,
15 ✕ 30 cm (Variation)

780 (31)
IP Cassette

Type CC
35 ✕ 43 cm (14” ✕ 17”),
35 ✕ 35 cm (14” ✕ 14”),
10” ✕ 12”, 8” ✕ 10”,
24 ✕ 30 cm, 18 ✕ 24 cm,
15 ✕ 30 cm (Variation)

Specifications are subject to change without notice.


FCR PRIMA II (CR-IR 391RU)
All brand names or trademarks are the property of their respective owners.
In some countries, regulatory approval may be required to import medical devices.
FCR PRIMA Console (CR-IR 391CL)
For the availability of these products, please contact your local sales representatives.

26-30, NISHIAZABU 2-CHOME, MINATO-KU, TOKYO 106-8620, JAPAN


http://www.fujifilm.com/products/medical/ Ref. No. XB-995E (SK·11·10·F1079·F9711) Printed in Japan ©2011 FUJIFILM Corporation

You might also like