Eng 01 A
Eng 01 A
Eng 01 A
Clamp Meters
Electrical Testers
Insulation Testers
Earth Ground Testers
Installation Testers
Portable Appliance Testers
Digital Thermometers
Thermal Imagers
Distance Meters
Indoor Air Quality Tools
ScopeMeter® Test Tools
Web: www.fluke.co.uk
© Copyright 2010, Fluke Corporation.
2010/2011
All rights reserved.
Printed in the Netherlands, 04/10
Data subject to alteration without notice.
Pub_ID: 11605-eng
Fluke web and electronic newsletter .................................................... 1 Laser Distance Meters ....................................................................... 64
New from Fluke........................................................................................ 2-3 421D/416D/411D Laser Distance Meters ........................................ 65
Fluke Combo Kits..................................................................................... 4-5
See page 122 for a Product Quick Find List per model number
New from Fluke
2
New from Fluke
3
Fluke Combo Kits
Fluke 87V/i410
Combo Kit for Industrial
Applications
Ordering Information • 87V Industrial Multimeter
• TL75 Test Leads
Fluke 117/322 Kit • AC72 Alligator Clips
Fluke 179/TPAK • i410 400A AC/DC Current
Fluke 179/61 Kit Clamp
Fluke 179/MAG2 Kit • 80BK-A Temperature Probe
Fluke 179/EDA2 Kit • C115 Soft Carrying Case
Fluke 87V/E2
Fluke 87V/i410 (Not available in all countries)
4
Fluke Combo Kits
Ordering Information
Fluke 287/FVF
Fluke 289/FVF Fluke 411D/62 Kit
Fluke 1587/ET • Fluke 411D Laser Distance
Fluke 1587/MDT Meter
Fluke T5-H5-1AC Kit • Fluke 62 Mini IR Thermometer
Fluke T5-600/62/IAC Kit • Soft case for each model
Fluke 62/322/1AC Kit
Fluke 411D/62 Kit
5
Application/
background articles
6
Let Fluke After Sales Service
help you further
Did you know that the Fluke after sales What other value added services do
service team can offer you much more we offer?
than just repairing and calibrating your • Gold Support for Fluke Networks
instrument when it is needed? Across • Gold CarePlans for calibration products
our whole Fluke European service • A full range of maintenance contracts
• Extended warranty programs
organization we have a vast range of
• Instrument upgrades
capabilities, which can be utilized via So why should you use Fluke service? • Option retrofits
your local service centre. Behind the • Original manufacturers’ parts used • Asset management
scenes Fluke draws on the expertise of • All instruments reviewed for latest updates • Calibration reminders
over 150 service staff that are focused • Repair warranty that covers whole unit
on offering only the best and most • In depth product knowledge What services do we offer you?
• Accredited calibrations available • 5 day repairs on all current products
comprehensive after sales service. • Traceable calibrations available on all • 5 days or less on all calibrations (excl.
products repairs)
• Full check of unit during verification cycle • 3 days for all Gold CarePlan calibrations
• Full safety test on mains powered units • 1-2 days on all Networks Gold calibration
• Pick up services where available
What other instruments can we help
you with?
We also offer a range of calibrations and
repairs on other manufacturer’s equipment
upon request. Manufacturers such as:
• Tektronix
• Agilent
• Bruel & Kjaer
• Philips
• Megger
• Seaward
• Kewtech
• Lecroy
• Hioki
• Yokogawa
• Druck
• Iwatzu
• plus many more ...
Fluke service centres handle a wide range
of equipment.
As part of Fluke’s continuing focus on improving
our service to our customer we now offer a
comprehensive range of repairs and calibrations
on a vast range of equipment. On-Line booking in system
Fluke manufactures equipments such as: Why not use our On-Line booking in system
where you can book your unit in, get pricing
and receive a RMA number for a smooth
Fluke Brands Instrument Types return.
Fluke Digital Multimeters
www.fluke.com/servicerma
Hart Scientific Electrical Standards
Fluke Networks Biomedical Equipment
Fluke Biomedical Data Loggers
Raytek Thermal Imagers
Reliable Power Meters Thermometers
Robin Pressure
LEM Instruments Function Generators
BEHA Oscilloscopes
Norma Installation Testers
Wavetek/Datron PAT Testers
Metron Clamp Meters
DHI Power Analyzers
Comark EX meters Contact Information
Plus many more
Eindhoven Norwich Cologne
Telephone +31 (0)40 267 5300 +44 (0)1603 256620 +49 (0)69 2222 20210
Telefax +31 (0)40 267 5321 +44 (0)1603 256688 +49 (0)69 2222 20211
Email [email protected] [email protected] [email protected]
Address Science Park 5108 52 Hurricane Way Heinrich-Pesch-Str. 9-11
Eindhoven Norwich 50739 Köln
5692 EC Son Norfolk Germany
Netherlands NR6 6JB
United Kingdom
7
Fluke: Where safety is built in
As distribution systems and loads Who Develops Safety Standards? of the 12 Ω test source for CAT II. The CAT III
become more complex, the possibilities The IEC (International Electrotechnical 600 V meter clearly offers superior transient
of transient overvoltages increase. Commission) develops international general protection compared to the CAT II 1000 V
standards for safety of electrical equipment meter, even though its so-called “voltage
Motors, capacitors and power conversion
for measurement, control and laboratory rating” could be perceived as being lower. See
equipment such as variable speed drives Table 2.
use. IEC61010-1 is used as the basis for the
can be prime generators of spikes. following national standards:
Lightning strikes on outdoor transmission • US ANSI/ISA-S82.01-94 Independent testing is the key to safety
lines also cause extremely hazardous • Canada CAN C22.2 No.1010.1-92 compliance
high-energy transients. If you’re taking • Europe EN61010-1:2001 How can you tell if you’re getting a genuine
measurements on electrical systems, CAT III or CAT II meter? Unfortunately it’s
these transients are “invisible” and Overvoltage Installation Categories not always that easy. It is possible for a
largely unavoidable hazards. They occur IEC61010-1 specifies categories of manufacturer to self-certify that its meter
regularly on low-voltage power circuits, overvoltage based on the distance the piece is CAT II or CAT III without any independent
of equipment is from the power source verification. The IEC (International
and can reach peak values in the many
(see Fig. 1 and Table 1) and the natural Electrotechnical Commission) develops and
thousands of volts. To protect you against damping of transient energy that occurs proposes standards, but it is not responsible
transients, safety must be built into the in an electrical distribution system. Higher for enforcing the standards. Look for the
test equipment. categories are closer to the power source and symbol and listing number of an independent
require more protection. testing lab such as UL, CSA, VDE, TÜV or other
Within each installation category there are recognized approval agency.
voltage classifications. It is the combination of These symbols can only be used if the product
installation category and voltage classification successfully completed testing to the agency’s
which determines the maximum transient standard, which is based on national and
withstand capability of the instrument.
Table 1
Overvoltage category In brief Examples
CAT IV Three-phase at utility connection, • Refers to the “origin of installation”; i.e., where low-voltage connection is made to utility power.
any outdoor conductors • Electricity meters, primary overcurrent protection equipment.
• Outside and service entrance, service drop from pole to building, run between meter and panel.
• Overhead line to d etached building, underground line to well pump.
CAT III Three-phase distribution, including • Equipment in fixed installations, such as switchgear and polyphase motors.
single-phase commercial lighting • Bus and feeder in industrial plants.
• Feeders and short branch circuits, distribution panel devices.
• Lighting systems in larger buildings.
• Appliance outlets with short connections to service entrance.
CAT II Single-phase receptable • Appliance, portable tools, and other household and similar loads.
connected loads • Outlet and long branch circuits.
• Outlets at more than 10 meters (30 feet) from CAT III source.
• Outlets at more than 20 meters (60 feet) from CAT IV source.
CAT I Electronic • Protected electronic equipment.
• Equipment connected to (source) circuits in which measures are taken to limit transient overvoltages
to an appropriately low level.
• Any high-voltage, low-energy source derived from a high-winding resistance transformer, such as the
high-voltage section of a copier.
Overvoltage installation categories. IEC 61010-1 applies to low-voltage (< 1000V) test equipment
8
Fluke: Where safety is built in
Safety is everyone’s responsibility but Select the right test tool: Inspect and test your test tool:
ultimately it is in your hands. • Choose a test tool rated to the highest • Check for a broken case, worn test leads or
No tool by itself can guarantee your safety category and voltage for which it could a faded display.
when working with electricity. It’s the possibly be used (most often 600 or 1000 • Make sure the batteries still deliver
volt CAT III and/or 600 volt CAT IV). sufficient power to get reliable readings.
combination of the right tools and safe
• Look for the category and voltage marking Many test tools have a low battery indicator
work practices that gives you maximum near the recessed input connectors of your on the display.
protection. Here are a few tips to help you test tool and a “double insulated” symbol • Check the test leads resistance for internal
in your work: on the back. breaks while moving the leads around
• Verify your test tool has been tested and (good leads measure 0.1-0.3 Ohm).
Make sure you always comply with (local) certified by two or more independent • Use the meter’s own test capability to
regulations. testing laboratories, such as UL in the ensure that the fuses are in place and
United States and VDE or TüV in Europe by working right (see manual for details).
looking for the symbols of these agencies
Work on de-energized circuits whenever
on (the back of) your test tool. Apply the appropriate working
possible. • Make sure that the test tool is made of
Use proper lock-out/tag-out procedures. If these practices when measuring on live
a high-quality, durable non-conductive circuits:
procedures are not in place or enforced, assume material.
that the circuit is live. • Hook on the ground clip first, then make
• Check the manual to verify that the contact with the hot lead. Remove the hot
ohms, continuity and capacitance circuits lead first, the ground lead last.
Use protective gear when working on live are protected to the same level as the • Use the three-point test method, especially
circuits: voltage test circuit, to reduce hazards when checking to see if a circuit is dead.
• Use insulated tools when the test tool is used incorrectly in First test a known live circuit. Second,
• Wear safety glasses or a face shield ohms, continuity or capacitance mode (if test the target circuit. Third, test the live
• Wear insulated gloves, remove watches or applicable). circuit again. This verifies that your test
jewelry • Verify that the test tool has internal tool worked properly before and after the
• Stand on an insulated mat protection to prevent instrument damage measurement.
• Wear flame resistant clothing, not ordinary when voltage is incorrectly applied to • Hang or rest the test tool if possible.
work clothes an amperage measurement function (if Try to avoid holding it in your hands, to
applicable). minimize personal exposure to the effects
• Make sure that the amperage and of transients.
voltage of your test tool’s fuses meets • Use the old electrician’s trick of keeping
specifications. Fuse voltage must be as high one hand in your pocket. This lessens the
or higher than the test tool’s voltage rating. change of a closed circuit across your chest
• Be sure to use test leads that have: and through your heart.
- Shrouded connectors
- Finger guards and a non-slip surface
- Category ratings that equal or exceed
those of the test tool
- Double insulation (look for the symbol)
- A minimum of exposed metal on the
probe tips
Use meters with these markings: Transient test values for overvoltage installation categories.
1000 V CAT III or 600 V CAT IV (50 V/150 V/300 V values not included)
9
Fluke Industrial Web Portal
Reduce downtime and unnecessary repairs
Incorrect motor
Overloading and mechanical strain could be signs that the motor is underperforming or inadequate for the job.
Use an infrared thermometer to quickly locate hot spots, and see areas of excessive heat with a thermal imager to determine severity. A digital
multimeter will determine if the current draw is too high, which is also a sign that the motor is inadequate for the demands placed on it. With
a clamp meter measure the inrush current and high load currents.
Fluke 87V True RMS Multimeter Fluke 337 True RMS Clamp Meter
• Accurate frequency and voltage • In-rush current function for motor
measurements on motor drives and starting, inductive lighting, etc.
electrically noisy environments. • AC/DC voltage and frequency
• Built-in thermometer measurements
• Jaw opening 42 mm
www.fluke.eu/industrial
Visit the full portal with practical information about troubleshooting potential problems throughout the plant.
See how to find the right test tool for the job.
10
Fluke Electrical Web Portal
A solution for every application
A voltage tester is the every day tester when working in an electrical installation, quickly check voltage or continuity. The T5 with its
OpenJawTM technology allows current measurement on tight spaces such as for example on a distribution board.
www.fluke.eu/electrical
Visit the full portal with practical information for the electrical installer.
See how to find the right test tool for the job.
11
Fluke Process Web Portal
Identifying potential problems
www.fluke.eu/process
Visit the full portal with practical information about troubleshooting potential problems in the process control
environment. See how to find the right test tool for the job.
12
Digital Multimeters
Safety, quality and performance: three words that sum up the benefits of
our extensive range of digital multimeters. Designed to help you do your
job faster, more efficiently and with greater accuracy, there is a model for
every budget and application. Choose from handheld troubleshooters to
ultra smart instruments packed with features, including the ability to log
and graph data, as well as high-precision bench units.
13
14
Remote Industrial maintenance Field Heavy duty General Auto-
Highest accuracy High-end Industrial Electrical HVAC/R Basic Electrical Loop calibration Insulation test
display and field service Service (IP67) Purpose motive
Basic features 289 287 233 87V 83V 179 177 175 117 116 115 114 113 27II 28II 77IV 88V 789 787 1587 1577
Counts 50000 50000 6000 20000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 20000 6000 20000 4000 4000 6000 6000
True RMS readings AC+DC AC+DC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC
Basic DC accuracy 0.025% 0.025% 0.25% 0.05% 0.1% 0.09% 0.09% 0.15% 0.5% 0.5% 0.5% 0.5% 2.0% 0.1% 0.05% 0.3% 0.1% 0.1% 0.1% 0.09% 0.2%
Wide bandwidth 100 kHz 100 kHz 20 kHz 5 kHz 20 kHz 50 kHz
Auto/manual ranging O/O O/O O/O O/O O/O O/O O/O O/O O/O O/O O/O O/O O/O O/O O/O O/O O/O O/O O/O O/O O/O
Measurements
Voltage AC/DC 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 600 V 600 V 600 V 600 V 600 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V
Current AC/DC 10 A 10 A 10 A 10 A 10 A 10 A 10 A 10 A 10 A 200 μA 10 A 10 A 10 A 10 A 10 A 1A 1A 400 mA 400 mA
Resistance 500 MΩ 500 MΩ 40 MΩ 50 MΩ 50 MΩ 50 MΩ 50 MΩ 50 MΩ 40 MΩ 40 MΩ 40 MΩ 40 MΩ 60 kΩ 50 MΩ 50 MΩ 50 MΩ 50 MΩ 40 MΩ 40 MΩ 50 MΩ 50 MΩ
Frequency 1 MHz 1 MHz 50 kHz 200 kHz 200 kHz 100 kHz 100 kHz 100 kHz 50 kHz 50 kHz 50 kHz 200 kHz 200 kHz 100 kHz 200 kHz 20 kHz 20 kHz 100 kHz
Capacitance 100 mF 100 mF 10 mF 10 mF 10 mF 10 mF 10 mF 10 mF 10 mF 10 mF 10 mF 10 mF 10 mF 10 mF 10 mF 10 mF 10 mF
Temperature +1350ºC +1350ºC +400ºC +1090ºC +400ºC +400ºC +1090ºC +1090ºC +500ºC
dB 60 dB 60 dB
Conductance 50 nS 50 nS 60 nS 60 nS 60 nS 60 nS 60 nS
Duty cycle/pulse width O/O O/O O/- O/- O/O O/O O/O
Continuity with beeper/Diode test O/O O/O O/O O/O O/O O/O O/O O/O O/O O/O O/O O/- O/O O/O O/O O/O O/O O/O O/O O/O O/-
4-20mA loop current as % readout O O
Motor drive measurement O O O O
RPM/Dwell O/-
VoltAlertTM, Non-contact voltage detection O
LoZ: low input impedance O O O O
VCHEKTM LoZ O
Microamps O O O O O
Insulation test O O
Number of insulation test ranges 5 2
Display
Dual display O O O O
Analog bargraph O O O O O O O O O O O O O O O O O
Backlight O O O O O O O O O O O O O O O O O O O O
Remote display O
Data storage and exchange
Min-Max recording/with time stamp O/O O/O O O/- O/- O/- O/- O/- O/- O/- O/- O/- O/- O/- O/- O/- O/- O/- O/- O/-
Fast Min-Max 250 μs 250 μs 250 μs 250 μs 250 μs
Display Hold/Auto (Touch) Hold O/O O/O O O/O O/O O/O O/O O/O O/- O/- O/- O/- O/- O/O O/O -/O O/O -/O -/O O/O
Relative O O O O O O O O O
Stand alone logging/TrendCapture O/O O/O
USB interface/RS232 interface O/O O/O O/O
Readings memories 10000 10000
Other features
Source 4-20mA loop current/24V loop supply O/O O/-
Automatic selection, AC/DC volts O O O
Real time clock O O
Smoothing O O O O
DMM Selection guide
Integrated holster O O O O O O O O
Removable holster O O O O O O O O O O O O O
Closed case calibration O O O O O O O O O O O O O O O O O O O O
Seperate battry/fuse access O/O O/O O/O O/- O/- O/O O/O O/O O/- O/- O/- O/- O/- O/O O/O O/- O/O O/- O/O O/O
Completely sealed/watertight O O
Automatic power off O O O O O O O O O O O O O O O O O O O O
Low battery indication O O O O O O O O O O O O O O O O O O O O
Warranty and safety
Lifetime warranty/warranty (years) O O 3 O O O O O 3 3 3 3 3 O O O O 3 3 3 3
Input alert O O O O O O O
Dangerous voltage indication O O O O O O O O O O O O O O O O O O O
EN61010-1 CAT III 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 600 V 600 V 600 V 600 V 600 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V
EN61010-1 CAT IV 600 V 600 V 600 V 600 V 600 V 600 V 600 V 600 V 600 V 600 V 600 V 600 V 600 V 600 V
See catalog page 15 15 16 17 17 18 18 18 19 19 19 19 19 21 21 20 22 101 101 37 37
280 Series Digital Multimeters
Specifications
(Check the Fluke web for detailed specifications)
True RMS
Functions Maximum Max. resolution 287 and 289**
Voltage DC 1000 V 1 μV ±(0.025% + 5)
Voltage AC 1000 V 1 μV ±(0.4% + 40)
Included Accessories Current DC 10 A 0.01 μA ±(0.15% +2)
TL71 silicone test leads, probe holder, 6 AA Current AC 10 A 0.01 μA ±(0.7% + 5)
batteries (installed), user manual, Calibration Temperature -200 ºC to 1350 ºC 0.1 ºC ±(1.0% + 1 ºC)
Certificate Sheet. Resistance 500 MΩ 0.01 Ω ±(0.05% + 2)
Conductance 50 nS 0.01 nS ±(1.0% + 10)
Capacitance 100 mF 0.001 nF ±(1.0% + 5)
Ordering Information Frequency 1 MHz 0.01 Hz ±(0.005% + 1)
Fluke 287 True-RMS Electronic logging
Accuracies are best accuracies for each function.
multimeter with TrendCapture ** 287 and 289 accuracy and resolution are stated for 50.000 counts
Fluke 289 True-RMS Industrial logging
Battery life: 50 hours minimum, Weight: 0,871 kg
multimeter with TrendCapture
180 hours in logging mode Lifetime warranty
Fluke 289/FVF Industrial logging multimeter
Size (HxWxD): 222 mm x 102 mm x 60 mm
and Software Combo Kit
(see page 5)
Fluke 287/FVF FlukeView Forms Combo Kit
(see page 5)
Recommended Accessories
FVF-SC2 FlukeView Forms software
including IR/USB cable
New
Ultimate flexibility with removable display
The NEW Fluke 233 remote display digital switch or an isolator switch. Wireless
multimeter allows you to be in two technology allows the display to be
places at once. The removable display carried up to 10 meters away from the
solves the problems of holding both point of measurement. The Fluke 233
the meter and the test leads to make a is also designed to work in areas where
measurement, making measurements the operator can’t be close to the active
in hard-to-reach places, and making measurement point, like clean rooms or
measurements in machines or panels hazardous areas.
that are physically separated from a limit
Features
233
Removable magnetic display O
True-RMS measurement O
Display backlight O
Built in thermometer O
Fluke 233
Display Hold and AutoHOLD ® O
Specifications
On all inputs
Fluke 233
Functions
Maximum Max. Resolution Accuracy
Voltage DC 1000 V 0.1 mV ±(0.25% + 2)
True RMS
Voltage AC 1000 V 0.1 mV ±(1.0% + 3)
Current DC 10 A 1 mA ±(1.0% + 3)
Current AC 10 A 1 mA ±(1.5% + 3)
Resistance 40 MΩ 0.1 Ω
Included Accessories Capacitance 9999 μF 1 nF
Test leads with 4mm lantern tips and Frequency 50.00 kHz 0.01 Hz
protective cap, AC 72 alligator clips, 80BK-A Temperature -40 ºC to +400 ºC
temperature probe, CD-ROM, AA batteries and Wireless frequency: 2.4 GHz ISM Band 10 meter range
user manual. Accuracies are best accuracies for each function
Ordering Information
Fluke 233 Remote Display Multimeter
Battery Life: AA alkaline (3 for main body, Weight: 0.6 kg
2 for display), 400 hrs typical Three year warranty
Size (HxWxD): 193 x 93 x 53 mm
Recommended Accessories
Input Alert O O
Specifications
Fluke 87V Ex
(Check the Fluke web for detailed specifications)
On all inputs
Functions Maximum Range 83V 87V/87V Ex*
Max.
Max. resolution Accuracy Accuracy
resolution
Voltage DC 1000 V 0.1 mV ±(0.1%+1) 10 μV ±(0.05%+1)
True RMS Voltage AC 1000 V 0.1 mV ±(0.5%+2) 10 μV ±(0.7%+2)
Current DC 10 A ** 0.1 μA ±(0.4%+2) 0.01 μA ±(0.2%+2)
not 87V Ex
Current AC 10 A ** 0.1 μA ±(1.2%+2) 0.01 μA ±(1.0%+2)
Resistance 50 MΩ 0.1 Ω ±(0.4%+1) 0.01 Ω ±(0.2%+1)
Included Accessories Conductance 60 nS 0.01 nS ±(1.0%+10) 0.001 nS ±(1.0%+10)
TL75 test leads, AC72 alligator clips, yellow Capacitance 9999 μF 0.01 nF ±(1.0%+2) 0.01 nF ±(1.0%+2)
holster (H80M excl. TPAK), 80BK temperature Frequency > 200 kHz 0.01 Hz ±(0.005%+1) 0.01 Hz ±(0.005%+1)
probe (87V only), 9 V battery (installed), Temperature -200 to 1090 ºC - 0.1 ºC 1.0%
CD-ROM (user’s manual and technical notes) 80BK temperature probe -40 to 260 ºC - - 2.2 ºC or 2%
and operator’s guide. Accuracies are best accuracies for each function.
* 87V accuracy is stated for 6000 counts and resolution for 20000 counts
** 20 A up to 30 seconds
Ordering Information Battery Life: Over 400 hours typical (alkaline). Weight: 0.6 kg
Fluke 83V Multimeter Size (HxWxD): 83V/87V: Lifetime Warranty
Fluke 87V True RMS Multimeter 200 mm x 95 mm x 48 mm 87V Ex: One Year Warranty
Fluke 87V Ex Intrinsically safe
True RMS multimeter Recommended Accessories
Fluke 87V/E2 Industrial Electrician Combo (Not for hazardous zones)
Kit
See page 4
Digital display counts, updates 4 times per second 6000 6000 6000
Display backlight O O
Fluke 177
Analog bargraph / 33 segments, updates 40 times per O O O
second
Auto and Manual ranging O O O
Specifications
On all inputs
(Check the Fluke web for detailed specifications)
Ordering Information Battery Life: Alkaline, 200 hrs typical Weight: 0.42 kg
Fluke 175 True RMS Multimeter Size (HxWxD): 190 mm x 85 mm x 45 mm Lifetime Warranty
Fluke 177 True RMS Multimeter
Fluke 179 True RMS Multimeter
Fluke 179/EDA2 Kit Electronics Combo Kit
Fluke 179/MAG2 Kit Industrial Combo Kit
See page 4 Recommended Accessories
Specifications
(Check the Fluke web for detailed specifications)
Functions Maximum Max. resolution 113 114 115 116 117
Fluke 113 Voltage DC 600V 1mV ±(0.5%+2) ±(0.5%+2) ±(0.5%+2) ±(0.5%+2) ±(0.5%+2)
Battery type: 9 volt Alkaline, 400 hours typical Weight: 0.55 kg (including batteries)
Ordering Information Size (HxWxD): 167 mm x 84mm x 46 mm Three Year Warranty
Fluke 113 True RMS Multimeter
Fluke 114 True RMS Multimeter
Fluke 115 True RMS Multimeter Recommended Accessories
Fluke 116 True RMS Multimeter
Fluke 117 True RMS Multimeter
Fluke 117/322 Kit Electricians Combo Kit
(see page 4)
C50 TL223 MC6 TPAK
See page 118 See page 110 See page 121 See page 120
19
77IV Digital Multimeter
Features
77 IV
Digital display counts 6000
Large display with backlight O
Min-Max-Average recording mode with Min/Max Alert O
High contrast digital display with large digits O
Analog bargraph/segments 31
Auto and Manual ranging O
Automatic Touch Hold® O
Audible continuity / diode test O
Ergonomic case with integrated holster O
Sleep Mode preserves battery life O
EN 61010-1 safety rating CAT IV 600 V / CAT III 1000 V
Fluke 77 IV
Specifications
Function Maximum Max. resolution Accurancy
Voltage DC 1000 V 1 mV ±(0.3%+1)
Voltage AC 1000 V 1 mV ±(2.0%+2)
Current DC 10 A 0.01 mA ±(1.5%+2)
Current AC 10 A 0.01 mA ±(2.5%+2)
Resistance 50 MΩ 0.1 Ω ±(0.5%+1)
Capacitance 9999 μF 1 nF ±(1.2%+2)
Frequency 99.99 kHz 0.01 Hz ±(0.1%+1)
Accuracies are best accuracies for each function.
On all inputs
Ordering Information
Fluke 77IV Multimeter i400 C35 Tpak TL225 TLK-225
See page 114 See page 118 See page 120 See page 121 See page 111
20
27II / 28II Rugged IP67 Industrial
Multimeters
Features
27 II 28 II
IP 67 waterproof & dustproof protection O O
True-RMS measurements O
Fluke 27 II
Digital display counts 6000 20000/6000
Built-in thermometer O
Ordering Information
Fluke 27 II IP 67 Industrial Multimeter
Fluke 28 II IP 67 True-RMS Industrial Multimeter
PV 350 i200 i410 80K-6
See page 113 See page 114 See page 115 See page 121 21
88V Automotive Meter
RPM80 Inductive Pickup for both conventional and distributorless (DIS) ignitions O
Specifications
On al inputs Fluke 88V
Range Resolution Accuracy
Voltage DC 1000V 0.1mV 0.1%
Voltage AC 1000V (5 kHz) 0.1mV 0.5%
Current DC 10A 0.1μA 0.4%
Current AC 10A 0.1μA 1.2%
Resistance 50MΩ 0.1Ω 0.4%
Capacitance 10mF 0.01nF 1%
Included Accessories Frequency 200kHz 0.01Hz 0.005%
H80M Holster with TPAK Meter Hanging Temperature 1090ºC 0.1ºC 1%
Solution, TL224 SureGrip Silicone Test Lead
Set, TP220 SureGrip Test Probe Set, AC285
SureGrip Large Jaw Alligator Clip Set, 80BK Battery Life: 88V – Over 400 hours typical Weight: 88V – 0.36 kg
Integrated Temperature Probe, RPM80 (alkaline) Lifetime Warranty
Inductive Pick-up Probe, C800 Hard Case, Size (HxWxD): 88V – 186 mm x 86 mm x 32 mm
User’s Manual + Quick Reference Guide
Ordering Information
Fluke 88V/A Automotive Meter Combo Kit
Recommended Accessories
Fluke 8846A
Features
8845A 8846A
Display Dual VFD Dot Matrix
Resolution 6.5 Digits
Measurement Rate (Rdgs/s) 1000
Use the built-in TrendPlot paperless chart recorder to Continuity / Diode Test Yes
graphically identify the extent of drift and intermittent Analytical Functions Statistics, Histogram, TrendPlot™, Limit Compare
events in analog circuits Math Functions NULL, Min/Max, dB/dBm
USB Device Port – USB Memory Drive port
Real Time Clock – Yes
Interfaces RS232, IEEE-488.2, Ethernet
Programming Languages/ SCPI (IEEE-488.2), Agilent 34401A, Fluke 45
Emulation Modes
Safety Designed to comply with IEC 61010-12000-1, ANSI / ISA-S82.01-1994, CAN /
View results in Histogram mode to reveal stability or CSA-C22.2 No.1010.1-92 1000V CATI / 600V CATII
noise problems in analog circuits
Specifications
(Check the Fluke web for detailed specifications)
8845A 8846A
Handle even the most demanding measurements with Function* Range Resolution Accuracy* (%) Range Resolution Accuracy* (%)
high accuracy and 6.5 digit resolution Voltage DC 1000 V 100 nV 0.0035 1000 V 100 nV 0.0024
Voltage AC (Freq 300 Hz) 750 V 100 nV 0.06 1000 V 100 nV 0.06
Resistance (2x4 Wire) 100 MΩ 100 μΩ 0.01 1 GΩ 10 μΩ 0.01
Current DC 10 A 100 pA 0.05 10 A 100 pA 0.05
True RMS Current AC (Freq. 3Hz-10kHz) 10 A 10 μA 0.10 10 A 100 pA 0.10
Freq/Period 300 kHz 1 μHz 0.01 1 MHz 1 μHz 0.01
Capacitance - - - 1 nF to 0.1 F 1 pF 1
Temperature RTD - - - -200 to +600º 0.001º 0.06
Included Accessories * Accuracy =+/- (% of reading)
LCI Line Power Cord, TL71 Test Lead Set,
Spare Line Power fuse, Programmers Manual/ Size (HxWxD): 88 mm x 215 mm x 293 mm
User Manual on CD-ROM, 884X-USB USB to Weight: 3.6 kg
RS232 Cable Adapter, FVF-BASIC FlukeView Three Year Warranty
Forms Software Basic Version.
Specifications
(Check the Fluke web for detailed specifications)
The ergonomic clamp meters feature wide opening jaws for safe, fast
non-contact current measurement. The Fluke leakage clamp meter is
ideal for non-invasive checks of insulation resistance.
The range of electrical testers includes two-pole testers for taking
quick measurements in tight spaces, phase rotation indicators to
take the guess work out of checking phase/motor rotation, a
multipurpose cable locator and handy voltage alerts.
25
330 Series/902 Clamp Meters
Fluke 337
Specifications
Functions Range 333 334 335 336 337 902
Current AC 0-400.0A 2% ± 5 counts
0-600.0A 2% ± 5 counts 2% ± 5 counts 2% ± 5 counts 1% ± 5 counts
0-999.9A 2% ± 5 counts
Crest Factor 0-600.0A 2.4 @ 500A 3 @ 500A 2.4 @ 500A
2.0 @ 600A 2.5 @ 600A 2.0 @ 600A
0-999.9A 3 @ 500A
2.5 @ 600A
1.42@ 1000A
Current DC 0-200 μA 1% ± 5 counts
0-600.0A 2% ± 5 counts
Fluke 902
0-999.9A 2% ± 5 counts
In-rush Integration
100mS 100mS 100mS 100mS
True RMS Current time
Voltage AC 0-600.0V 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts
Voltage DC 0-600.0V 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts
Resistance 0-600.0Ω 1.5% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts
Included Accessories 0-6000Ω 1.5% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts
0-9999Ω 1.5% ± 5 counts
C33 Soft case, TL75 test leads, 80BK Integrated
Continuity ≤ 30Ω ≤ 30Ω ≤ 30Ω ≤ 30Ω ≤ 30Ω ≤ 30Ω
DMM temperature probe (902),
Frequency 5-400Hz 0.5% ± 5 counts
2 AA alkaline batteries, instruction card and Temperature -10° to 400°C 1% ± 0.8°C
safety information sheet. Capacitance 1μF to 1000μF 1.9% ± 2 counts
Ordering Information Battery Life: Alkaline, 150 hours Jaw Opening: 30 mm (333, 334, 335 and 902)
Fluke 333 Clamp Meter Size (HxWxD): 42 mm (336, 337)
Fluke 334 Clamp Meter 238 mm x 79 mm x 41mm (333, 334, Weight: 0.312 kg
Fluke 335 True-RMS Clamp Meter 335 and 902) Three Year Warranty
Fluke 336 True-RMS Clamp Meter 251 mm x 79 mm x 41 mm (336 and 337)
Fluke 337 True-RMS Clamp Meter
Fluke 902 True-RMS Clamp Meter Recommended Accessories
(HVAC)
H3 TL223 L215
See page 119 See page 110 See page 111
26
320 Series Clamp Meters
Features
Functions 321 322
Compact design O O
Auto shut-off O O
Display Hold O O
Low battery indication O O
Current AC O O
Volts DC O
Fluke 322
Specifications
321 322 321 322
Fluke 321 Functions Range Resolution Range Resolution Best Accuracy
Current AC 400.0A 0.1A 40.00A 0.01A 1.8% ± 5 counts 1.8% ± 5 counts
400.0A 0.1A (50 - 60Hz) (50 -60Hz)
3.0% ± 5 counts 3.0% ± 5 counts
(60Hz - 400Hz) (60Hz - 400Hz)
Voltage AC 0-400.0V 0.1V 0-400.0V 0.1V 1.2% ± 5 counts 1.2% ± 5 counts
400-600V 1V 400-600V 1V (50-400Hz) (50-400Hz)
Voltage DC 0-400.0V 0.1V 1% ± 5 counts
400-600V 1V
Resistance 0-400.0Ω 0.1Ω 0-400.0Ω 0.1Ω 1% ± 5 counts 1% ± 5 counts
Continuity ≤ 30Ω ≤ 30Ω
H3 TL223 L215
See page 119 See page 110 See page 111
27
350 Series AC/DC Clamp Meters
Features
353 355
True-RMS measurements O O
Display backlight O O
Motor start-up current O O
Min/Max/Average O O
Voltage AC/DC O
Fluke 353 Resistance measurement O
Continuity measurement with beeper O
Specifications
(Check the Fluke web for detailed specifications)
Included Accessories
Fluke 353: C43 Soft Meter Case, 6 AA batteries, Power Supply: 6 x 1.5V AA NEDA 15A Size (HxWxD): 300 mm x 98 mm x 52 mm
users manual or IEC LR6 Jaw opening: 58 mm
Fluke 355: C43 Soft Meter Case, 6 AA batteries, Battery Life: 100 hours (with typical Weight: 0.814 kg
TL224 SureGrip® Silicone Test Lead Set, TP2 usage, backlight off) Two year warranty
Slim Reach Test Probe Set (2 mm), AC285
SureGrip® Alligator Clip Set, users manual
Ordering information
Fluke 353 AC/DC Clamp Meter
Fluke 355 AC/DC Clamp Meter Recommended Accessories
Fluke 360
Specifications
(Check the Fluke web for detailed specifications)
Included accessories
Soft carrying pouch and users manual display: 1.7mA
29
T100 Series
Voltage and Continuity Testers
Fluke T120
Features
T100 T120 T140
Display LCD LCD
Led Bargraph 12 LED’s 12 LED’s 12 LED’s
Backlight O
Resistance measurement O
Switchable load O
Voltage test O O O
Fluke T140
Optical and acoustical continuity test O O O
Rotary field indication O O O
Single pole test for phase detection O O O
Indication of polarity O O O
Fluke T100 Electrical torch function O O O
Probe tip protection O O O
The voltage display also functions when using O O O
discharged - or o batteries
Specifications
T100 T120 T140
Voltage AC/DC 12 - 690 V 12 - 690 V 12 - 690 V
Continuity 0 - 400 kΩ 0 - 400 kΩ 0 - 400 kΩ
Frequency 0 - 400 Hz 0 - 400 Hz 0 - 400 Hz
Phase rotation 100 to 690 V 100 to 690 V 100 to 690 V
Resistance measurement - - Up to 1999 Ω
Included Accessories Response time < 0.1 s < 0.1 s < 0.1 s
Two 1.5V batteries and instruction sheet
Ordering Information
Fluke T100 Voltage/Continuity Tester
Size (HxWxD): 240 mm x 56 mm x 24 mm
Fluke T120 Voltage/Continuity Tester Case: IP65 (water-jet and dust tight protection)
Fluke T140 Voltage/Continuity Tester Weight: 180 g
Two year warranty
UK versions are compliant with GS38
Recommended Accessories
The ideal kit for busy electrical This kit is designed to help electricians
contractors and electricians. The benefits and HVAC technicians solve problems
of a voltage and current meter and non- quicker. Test first for overheated electrical
Fluke T5-H5-1AC Kit
contact voltage detector all in one kit. A devices using an IR thermometer; then
holster for the T5 is also included. use elecrtrical test tools to find out more
about the problem.
Kit includes:
- Fluke T5-1000 Kit includes:
- H5 holster • Fluke T5-600
Fluke T5-600/62/1ACII Kit - Free Fluke 1AC-II • Fluke 62
• Fluke 1AC II
• C115
Included Accessories
TP4 4 mm detachable probes (detachable GS38
probes for the UK) and instruction sheet
Ordering Information
Fluke T5-600 Electrical Tester
Fluke T5-1000 Electrical Tester
Fluke T5-H5-1AC Kit Electrical Tester with
holster and IAC
Fluke T5-600/62/1AC Electrical Tester,
IR Thermometer,
Voltage Detector Kit
Recommended Accessories
H5 ACC-T5-Kit AC285
See page 119 See page 111 See page 112
31
1AC II Volt Alert
LVD1/LVD2 Volt Lights
SM100/200/300 SocketMaster-testers
Ordering Information
Fluke 1AC II VoltAlert
Fluke 1AC II 5PK VoltAlert (5-pack)
LVD1 Volt Light
LVD2 Volt Light
SM100 SM200 SM300
SM100 SocketMaster Tester
SM200 SocketMaster Tester
SM300 SocketMaster Tester
Only available with UK plug
Features
SM100 SM200 SM300
Clear indication of wiring status O O O
Audible notification of wiring status O O
Unique soft-touch RCD test checks 30 mA RCD´s for trip O
within 300 ms
Earth Volts Touchpad detects raised earth voltages >50 V, O
indicating potentially dangerous situations
32
9040/9062
Phase Rotation Indicators
Fluke 9040
Features
9040 9062
3 phase indication Via LCD Via LED
Indication of phase rotation O O
Indication of motor rotation direction O
Contact free determination of the rotation direction of running motors O
Clear LCD display O
No battery required O
Fluke 9062
9040:
Specifications
9040 9062
Voltage range 40 - 700 V Up to 400 V
Phase display - 120 - 400 V AC
Frequency range 15 - 400 Hz 2-400 Hz
9062:
Operating time Continuous Continuous
Size (HxWxD) Fluke 9040: Power supply 9040: from unit under test
124 mm x 61 mm x 27 mm Power supply 9062: 1 x 9V
Size (HxWxD) Fluke 9062: Weight 9040: 0.20 kg
124 mm x 61 mm x 27 mm Weight 9062: 0.15 kg
Two Year Warranty
Ordering Information Determine the presence of Determine the rotation of Check the correct rotation of
Fluke 9040 Phase Rotation Indicator phase sequence of multiphase running motors simply by motors prior to connection.
Fluke 9062 Motor and Phase Rotation electrical supplies. placing the instrument on
Indicator the motor casing.
Recommended Accessories
Included Accessories
TL27 Heavy Duty Test Lead Set (2)
TP74 Lantern Tip Test Probe Set
AC285 Alligator Clip Set
Soft carrying case
Hard case
Location of fuses/breakers Tracing of underground Precise location of cable
and assignment to circuits cables (max. depth 2.5 m) interruptions with additional
Ordering Information transmitter
Fluke 2042 Cable Locator
(transmitter + receiver)
Fluke 2042T Cable Locator Transmitter
Recommended Accessories
Fluke 2042T
34
Insulation Testers and
Earth Ground Testers
35
Insulation Tester
Selection Guide
Multimeter Functionality
AC/DC Volts O O O O O
Current O O O
Resistance O O O O O
Temperature (contact) O O
Lo-Pass Filter O O
Capacitance O O O
Diode Test O O
Frequency O O
MIN/MAX
O O
Other
Hold/Lock O O O O O O
Backlight O O O O O
(Fluke View® Forms
Software
Basic)
Warranty (in years) 3 3 3 1 1 2
4 AA (NEDA 15A or 4 AA (NEDA 15A or 4 AA (NEDA 15A or 4 AA (NEDA 15A or 4 AA (NEDA 15A or
Battery Rechargeable
IEC LR6) IEC LR6) IEC LR6) IEC LR6) IEC LR6)
Fluke 1587/MDT
36
1503/1507 Insulation Testers
Features
1503 1507
User selectable test voltages for many applications O O
Additional test voltages 50V, 100V, 250V O
Special remote control probe for easy and safe measurements O O
Auto-discharge of capacitive voltage for added user protection O O
Fluke 1503 Live circuit detection prevents insulation test if voltage > 30 V O O
is detected for added user protection
Save both time and money with Automatic calculation of O
Polarization Index and Dielectric Absorption Ratio
Auto Power off to save batteries O O
Large display with backlight O O
Continuity function (200 mA) O O
Compare function (pass/fail) for fast repetitive tests O
Fluke 1507
Specifications
Insulation specifications 1503 1507
Insulation test range 0.1 MΩ to 2 GΩ 0.01 MΩ to 10 GΩ
Test voltages 500 V, 1000 V 50 V, 100 V, 250 V, 500 V, 1000 V
Test voltage accuracy + 20 %, - 0 % + 20 %, - 0 %
Insulation test current 1mA nominal 1mA nominal
AC/DC Voltage measurement 600 V (0.1 V resolution) 600 V (0.1 V resolution)
Resistance measurement range 0.01 Ω to 20 kΩ 0.01 Ω to 20 kΩ
Auto discharge Discharge time < 0.5 second Discharge time < 0.5 second
for C = 1 μF or less for C = 1 μF or less
Maximum capacitive load Up to 1 μF Up to 1 μF
Open circuit test voltage > 4V ,< 8V > 4V ,< 8V
Short circuit current > 200 mA > 200 mA
Ordering Information
Fluke 1503 Insulation Tester Insulation test at a Wiring test in a small
Fluke 1507 Insulation Tester distribution panel distribution box –
all in one spot
Recommended Accessories
Features
Multimeter Features 1577 1587 1587T
True RMS Voltage and Current for accurate measurements O O O
Digital display counts 6000 6000 6000
Autorange and manual range for easy testing. O O O
Selectable filter for accurate voltage and frequency measurements on motor O O
drives
Min Max Recording, Diode test, temperature, capacitance & frequency O O
measurement for maximum flexibility.
Fluke 1577
Insulation features
User selectable test voltages for many applications O O
Additional test voltages 50V, 100V, 250V O
Special remote control probe for easy and safe measurements O O O
Auto-discharge of capacitive voltage for added user protection O O O
Live circuit detection prevents insulation test if voltage > 30V is detected for O O O
added user protection
General features
Auto Power off to save batteries O O O
Large display with backlight O O O
Fluke 1587 Input Alert to warn for incorrect connections O O O
Fluke 1587T
Continuity O O O
Insulation Specifications
Functions 1577 1587 1587T
Measurement range 0.1MΩ to 600MΩ 0.01MΩ to 2GΩ 0.01MΩ to 100MΩ
Test voltages 500V, 1000V 50V, 100V, 250V, 500V, 50V, 100V
1000V
Test voltage accuracy + 20%, -0% + 20%, -0% + 20%, -0 %
Insulation test current 1mA nominal 1 mA nominal 1 mA nominal
Auto discharge Discharge time < 0.5s Discharge time <0.5s Discharge time <0.5s
for C = 1 μF or less for C = 1 μF or less for C = 1 μF or less
Maximum capacitive load Up to 1 μF load Up to 1 μF load Up to 1 μF load
Multimeter Specifications
Functions Maximum Max. resolution 1577 1587/1587T
Voltage DC 1000V 1 mV ± (0.2% + 2) ± (0.09% + 2)
Voltage AC 1000V 0.1mV ± (2% + 3) ± (2% + 3)
Current DC 400mA 0.01mA ± (1.0% + 2) ± (0.2% + 2)
Current AC 400mA 0.01mA ± (2% + 2) ± (1.5% + 2)
Resistance 50.0MΩ 0.1Ω ± (1.2% + 2) ± (0.9% + 2)
Capacitance 9999μF 1 nF - ± (1.2% + 2)
Frequency 99.99kHz 0.01 Hz - ± (0.1% + 1)
Temperature -40°C to +537°C 0.1°C - ± (1% + 10)
Included Accessories
C101 Rugged, utility hard case Battery life: Meter: 1000 hrs, Weight: 0.55 kg
TL224 SureGrip Silicone Test Lead Set Insulation Test: >1000 tests Three Year Warranty
AC285 SureGrip Alligator Clip Set Size (HxWxD):
203 mm x 100 mm x 50 mm
80BK Integrated DMM Temperature Probe
(Type K) Recommended Accessories
TP165X Remote Test Probe
Ordering Information
Fluke 1577 Insulation Multimeter
Fluke 1587 Insulation Multimeter
Fluke 1587T Insulation Multimeter C25 i400 TPAK L215 TL238
See page 118 See page 114 See page 120 See page 111 See page 110
(for Telecom)
37
1550B MegOhmMeter
Fluke 1550B
Specifications
Test Voltage (DC) Range Accuracy (+/- reading)
250V 200kΩ to 5GΩ 5%
5GΩ to 50GΩ 20%
500V 200kΩ to 10GΩ 5%
10GΩ to 100GΩ 20%
1000V 200kΩ to 20GΩ 5%
20GΩ to 200GΩ 20%
2500V 200kΩ to 50GΩ 5%
50GΩ to 500GΩ 20%
5000V 200kΩ to 100GΩ 5%
100GΩ to 1TΩ 20%
Short circuit current greater than 1 mA and less than
2mA
Bar graph range 0 to 1TΩ
Insulation test voltage accuracy 0% to + 10% at 1mA load current
Induced AC mains current rejection 2 mA maximum
Charging rate for capacitive load 5 seconds per μF
Included Accessories
Test leads, 5000 V-rated probes, Alligator clips,
Interface cable
Flukeview Forms Basic, soft carrying case with Operating Temperature: -20°C to 50°C Batteries: 12 volt, lead-acid, rechargeable
water-proof bottom, instruction manual Storage Temperature: -20°C to 65°C Size (HxWxD): 170 mm x 242 mm x 330 mm
Relative humidity: 80% at 31°C, Weight: 4 kg (with battery)
50% at 50°C Two Year Warranty
Ordering Information Dust/water resistance: IP40
Fluke 1550B MegOhmMeter Operating Altitude: 0 to 2,000 mtrs.
FVF-SC2
See page 120
39
1620 Series
Earth Ground Testers GEO
Features
1623 1625
One-button measurement concept O
3- and 4-pole earth ground measurement O O
4-Pole soil resistivity testing O O
2-Pole resistance measurement AC O O
Fluke 1625
2-and 4-pole resistance measurement DC O
Selective testing, no disconnection of ground conductor (1 clamp) O O
Stakeless testing, quick ground loop testing (2 clamps) O O
Measuring frequency 128 Hz O
Earth impedance measurement at 55 Hz O
Automatic frequency control (AFC) (94 – 128 Hz) O
Measuring voltage switchable 20/48V O
Programmable limits, settings O
Continuity with buzzer O
Dust/water resistance IP56 IP56
Safety rating CAT II 300 V CAT II 300 V
Specifications
(Check the Fluke web for detailed specifications)
1623 1625
Fluke 1625 kit
Resistance ranges 0 to 20 kΩ 0 to 300 kΩ
Operating error ± 5% ± 5%
Included accessories Test voltage 48 V 20 / 48 V
Fluke 1623: Protective holster, 2 test leads, Short circuit current > 50mA 250 mA
2 alligator clips, users manual
Fluke 1623 Kit: same as above plus stake/reel
Set 4 pole and selective/stakeless clamp set Battery type: 6 x AA alkaline cells
Fluke 1625: Protective holster, 2 test leads, Size (HxWxD): 110 mm x 180 mm x 240 mm
Weight – 1623 Geo: 1.1 kg (including batteries)
2 alligator clips, users manual
1625 Geo: 1.1 kg (including batteries)
Fluke 1625 Kit: same as above plus stake/reel Two Year Warranty
set 4 pole and selective/stakeless clamp set
Fluke 1621
Specifications
(Check the Fluke web for detailed specifications)
1621
Resistance range 0.15 Ω to 2 kΩ
Basic accuracy ± 6% of measured value + 5D
Operating error according EN61557 ± 18% of measured value +5D
Test voltage 23 to 24 V AC
Short circuit current > 50 mA AC
Recommended Accessories
Included accessories
Two measuring leads with alligator clips -
2 m, protective holster, users manual, CD-ROM
Ordering information
Fluke 1621 Earth Ground Tester
GEO CABLE-REEL 25M GEO CABLE-REEL 50M GEO EARTH STAKE ES-162P3
Ground Earth Cable Reel Ground Earth Cable Reel Ground Earth Stake Stake/reel set for 3 pole
25 M Wire 50 M Wire measurements
41
1630 Earth Ground
Clamp Meter
Specifications
(Check the Fluke web for detailed specifications)
Weight: 0.64 kg
Conductor Size: 35 mm approx.
Size (HxWxD): 257 mm x 100 mm x 47 mm
Battery type: 9 V IEC 6 LR 61
Two Year Warranty
Rg R1 R2 R3 .....Rn
Included Accessories
Rugged carrying case with belt, Resistance test R1 R2 .....Rn
loop, 9 V battery, Operating instructions.
Ordering Information
Fluke 1630 Earth Ground Clamp Meter Rg
Rg
42
Installation Testers/
Portable Appliance Testers
43
1650B Series Multifunction
Installation Testers
Ordering Information
Fluke 1651B Multifunction Installation Tester
Fluke 1652B Multifunction Installation Tester
Fluke 1653B Multifunction Installation Tester Recommended Accessories
See also page 48 for more details
Check the Fluke website for the various
software modules
Specifications
(Check the Fluke web for detailed specifications)
AC Voltage Measurement
Range Resolution Accuracy Input Impedance Overload Protection
50 Hz – 60 Hz
500 V 0.1 V ± (0.8% + 3 digits) 3.3 MΩ 660 Vrms
Continuity Testing
Range Resolution Test Current Open Circuit Voltage Accuracy
(autoranging)
20 Ω 0.01 Ω
200 Ω 0.1 Ω > 200 mA > 4V ± (1.5%+3 digits)
2000 Ω 1Ω
45
6000 Series PAT Testers
6200 6500
• Dedicated key for each test for ‘one- As 6200 but also with:
touch’ testing • Integral QWERTY keyboard for rapid
• Pre-set pass/fail levels to save time data entry
Fluke 6500 • Large backlit display for easy reading • Slot for Compact Flash memory card for
back-up data storage and transfer to PC
• Pre-set, auto-test sequences for user
Also available with European mains socket. convenience
Features
Measurement functions 6200 6500
L N Mains Volts O O
Outside Limits Indicators O O
Null out facility for earth bond lead O O
Protective Earth Resistance PE (200mA) O O
Protective Earth Resistance PE (25A) O O
Insulation 500V dc O O
Protective Earth Conductor Current O O
Touch Current O O
Substitute Leakage Current O O
Appliance Power kVA O O
Appliance Load Current O O
Seven Segment Custom LCD O
Included Accessories Graphical LCD O
Test lead, Test probe, Crocodile clip, Back Light O O
Mains cord Compact Flash Card receptacle O
Serial Port - Printing / Downloading O O
46
6000 Series PAT Testers
Specifications
The accuracy specification for the display range is defined as ± (%reading + digit counts) at 23 °C ± 5 °C, ≤ 75 %
RH. Between 0 °C and 18 °C and between 28 °C and 40 °C, accuracy specifications may degrade by 0.1 x (accuracy
specification) per °C. The measurement range meets the service operating errors specified in EN61557-1: 1997,
EN61557-2: 1997 , EN61557-4: 1997.
during transit but also includes extra storage space for Accuracy at 50 Hz ± (2% + 3 counts)
Resolution 0.01 mA
accessories and other tools. They’re extremely light, Resolution 0.1V (1V - model 6200)
Internal Resistance (via probe) 2 kΩ
Measuring method Probe
weighing approximately 3 kg (without case) and have Input Impedance > 1 MΩ // 2.2 μF
The appliance under test is energized at mains potential.
integral carrying handles for extra convenience. Maximum Input Mains Voltage 300 V
Display Screens
Size (HxWxD): 200 mm x 275 mm x 100 mm
Weight: 3 kg
Two Years Warranty
Recommended Accessories
See also page 48 for more details
Accessories for Fluke 1650B Accessories for Fluke 6500 Series Portable
Series Installation Testers Appliance Testers
48
Digital Thermometers
49
50
Infrared Thermometer Fluke 60 Series Fluke 560 Series Fluke 570 Series
Selection Guide Fluke 61 Fluke 62 Fluke 63 Fluke 66 Fluke 68 Fluke 561 Fluke 566 Fluke 568 Fluke 572 Fluke 574
Temperature range -18 to 275 ºC -30 to 500 ºC - 32 to 535 ºC - 32 to 600 ºC - 32 to 760 ºC - 40 to 550 ºC - 40 to 650 ºC - 40 to 800 ºC - 30 to 900 ºC - 30 to 900 ºC
Accuracy 2% 1.5% 1% 1% 1% 1% 1% 1% 0.75% 0.75%
Response time < 500 mSec < 500 mSec < 500 mSec < 500 mSec < 500 mSec < 500 mSec < 500 mSec < 500 mSec < 250 mSec < 250 mSec
Optical resolution 8:1 10:1 12:1 30:1 50:1 12:1 30:1 50:1 60:1 (50:1 60:1 (50:1
with close with close
focus) focus)
Close focus model O O
available
Recommended distance Up to 2 m Up to 2 m Up to 2.5 m Up to 4.5 m Up to 7.5 m Up to 2.5 m Up to 4.5 m Up to 7.5 m 300 mm 300 mm
to spot (with close (with close
focus) up to focus) up to
10.5 m 10.5 m
Laser sighting single-point single-point single-poimt single-point single-point single-point single-point single-point 3-point 3-point
laser laser laser laser laser laser laser laser laser laser
Adjustable emissivity O O O O O O O
MIN/MAX readings -/O -/O O O O O O O O
AVG readings O O O O O
DIF readings O O O O O O
Backlit LCD O O O O O O O O O O
Bar graph display O O
Audible Hi/Lo alarm O O O O O/- O
Visible Hi/Lo alarm O O O O O/- O
Includes contact probe O O O O
Probe input (types) Type K Type K Type K Type K
RTD RTD
Thermocouple Thermocouple Thermocouple Thermocouple
Data logging (number of
12 points 12 points 20 points 99 points 100 points
measurements)
PC interface USB RS232
Compatible with
FlukeView Forms O O
software
Recommended Applications
Selection Guide
Infrared Thermometer
Contact thermometers Plant/facilities maintenance Heating/ventilation/air conditioning/ Manufacturing processes Safety and protection
For our complete range of contact Preventive and predictive maintenance refrigeration Molding temperature measurement Fire localization
thermometers, see page 55. Energy audits Leaky ductwork Printing, paper and converting Hazardous materials
Vehicle and fleet maintenance Thermostats Thermoforming plastics Faulty ballasts
programs Temperature balancing Electronics Search and rescue
Faulty electrical/circuit connections Steam distribution systems Paint curing/drying Smoldering embers
Petrochemical/hazardous locations Compressor lines Food Equipment maintenance
Motors, pumps and bearings Chemical and pharmaceutical
570 Series
Precision Infrared Thermometers
Fluke 574
Features
572 574
Temperature range -30 to 900ºC
Optical resolution Standard: 60:1
Close focus: 50:1
3 dot laser beam for accurate targeting O O
Adjustable emissivity O O
Bar graph display O O
Backlit LCD display O O
Use selectable ºC or ºF O O
Audible and visible Hi/Lo Alarm O/- O/O
MIN/MAX O O
AVG/DIF readings O
Datalogging (number of measurements) 100
PC interface RS232
Specifications
572 574
Temperature range -30 to 900°C
Response time 250ms (95 % of reading)
Resolution 0.1°C of reading up to 900°C
Fluke 572
Repeatability ±0.5% of reading or ±1°C*
Accuracy: (assumes ambient operating temperature of 23 ºC to 25 ºC ) ±0.75% of reading, ±0.75°C *
Typical distance to target 10,5 m
Emissivity Digitally adjustable from 0.10 to 1.0
by 0.01
Included Accessories *whichever is greater.
Fluke 572: Hard case, 2 batteries
Fluke 574: Hard case, 2 batteries, Thermocouple
K probe, 220V power supply, IRGraph software,
RS232 cable Battery Life: 10 hours typical
Weight: 0.480 kg
Size (HxWxD): 200 mm x 170 mm x 55 mm
Ordering Information Two years warranty
Fluke 572 Precision Infrared Thermometer
Fluke 574 Precision Infrared Thermometer
Fluke 572CF Precision Infrared Thermometer
with close focus option Recommended Accessories
Fluke 574CF Precision Infrared Thermometer
with close focus option
AN5 C570
Analog data cable See page 118
51
60 Series
Infrared Thermometers
Specifications
61 62 63 66 68
Range - 18 to 275ºC - 30 to 275 ºC - 32 to 535 ºC - 32 to 600 ºC - 32 to 760 ºC
Response time < 500ms < 500ms ≤ 0.5 second ≤ 0.5 second ≤ 0.5 second
(95 % of reading)
Resolution 0.2 ºC 0.2 ºC 0.2 ºC 0.1 ºC 0.1 ºC
* whichever is greater
Ordering information
Fluke 61 Infrared Thermometer
Fluke 62 Mini Infrared Thermometer Kits Recommended Accessories
Fluke 63 Infrared Thermometer
Fluke 66 Infrared Thermometer
Fluke 68 Infrared Thermometer
Fluke 62/322/1AC (see page 5)
Fluke T5-600/62/1AC (see page 5)
C23 80PR-60 H6
See page 118 See page 117 See page 119
52 Fluke 62/322 kit T5-600/62/1AC
566 and 568
Multipurpose Thermometers
Fluke 568
Choose your language Select the measurement surface See complete measurement details
in seconds
Specifications
(Check the Fluke web for detailed specifications)
566 568
Infrared temperature range -40 °C to 650 °C -40 °C to 800 °C
Infrared accuracy < 0 °C : ± (1.0 °C + 0.1°/1 °C);
> 0 °C : ± 1 % or ± 1.0 °C, whichever is greater
Display resolution 0.1 °C
Infrared spectral response 8 μm to 14 μm
Infrared response time < 500 msec
The Fluke 566 and included accessories Input temperature range -270 °C to 1372 °C
Input accuracy -270 °C to -40 °C: ± (1 °C + 0.2 °/1 °C)
-40 °C to 1372 °C: ± 1 % or 1 °C, whichever is greater
D:S (Distance to measurement spot size) 30:1 50:1
Laser sighting Single-point laser < 1 mw output Class 2 (II) operation, 630 nm to 670 nm
Minimum spot size 19 mm
Emissivity adjustment By built-in table of common materials or digitally adjustable
from 0.10 to 1.00 by 0.01
Data logging with Date/Time stamp 20 points 99 points
PC interface and cable None USB 2.0 with FlukeView®
Forms software
Hi/Low alarms Audible and two-color visual
Min/Max/Avg/Dif Yes
Display Dot matrix 98 x 96 pixels with function menus
Backlight Two levels, normal and extra bright for darker environments
Trigger Lock Yes
Switchable between Celsius and Fahrenheit Yes
The Fluke 568 and included accessories Power: 2 AA/LR6 Batteries (566); 2 AA/LR6 Weight: 0.965 kg (566); 1.026 kg (568)
Batteries and USB for use with a PC (568) Size (HxLxW): 25.4 cm x 19.1 cm x 6.9 cm
Battery life: Used continuously; laser and Operating temperature: 0 °C to 50 °C
backlight on: 12 hours; laser and backlight off: Storage temperature: -20 °C to 60 °C
100 hours Two years warranty
Included accessories
FlukeView® Forms software (568 only), USB
cable (568 only), K-type thermocouple bead
probe, 2 AA batteries, hard carrying case,
quick start guide, and users manual. Recommended Accessories
Ordering information
Fluke 566 Infrared thermometer
Fluke 568 Infrared thermometer
Specifications
Included accessories
Thermocouple K-type Velcro pipe probe,
hand carrying case, 2 AA batteries and user
manual with measurement guide.
Recommended Accessories
Ordering information
Fluke 561 HVACPro Thermometer
Features
51 II 52 II 53 II 54 II
Thermocouple types J,K,T,E J,K,T,E J,K,T,E,N,R,S J,K,T,E,N,R,S
Fluke 54 II Number of inputs Single Dual Single Dual
Time stamp Relative Time Relative Time Time of Day Time of Day
Splash/Dust resistant O O O O
Dual display with backlight O O O O
Min/Max/Avg recording O O O O
(T1-T2) True differential O O
Data logging up to 500 points O O
IR data port for interface O O
to PC
Compatible with optional O O
FlukeView Software
Specifications
Fluke 51 II Fluke 52 II Fluke 53 II Temperature range:
J-type Thermocouples -210°C to 1200°C
K-type Thermocouples -200°C to 1372°C
T-type Thermocouples -250°C to 400°C
E-type Thermocouples -150°C to 1000°C
N-type** Thermocouples -200°C to 1300°C
R** and S-type** Thermocouples 0°C to 1767°C
Temperature accuracy
Above –100°C (-148°F):
Included Accessories J, K, T, E, and N-type** ± [ 0.05% + 0.3°C ]
Impact absorbing holster R** and S-type** ± [ 0.05% + 0.4°C ]
Two bead probe thermocouples 80PK-1 (54+52) Below –100°C (-148°F):
One bead probe thermocouple 80PK-1 (51+53) J, K, E, and N-types ± [ 0.20% + 0.3°C ]
T-type ± [ 0.50% + 0.3°C ]
Ordering Information **Only the Fluke Models 53 and 54 Series II thermometers are capable of measuring N, R, and S-type
Fluke 51 II Thermometer
Fluke 52 II Thermometer Battery life: 1000 hours typical, AA Weight: 0.4 kg
Fluke 53 II Thermometer Size (HxWxD): 173 x 86 x 38 mm Three Year Warranty
Fluke 54 II Thermometer
FVF-SC1 FlukeView Forms Software
including interface cable
Recommended Accessories
A new standard in
accuracy and versatility.
Measure, graph and record three High accuracy
sensor types with one tool. The Fluke • PRTs: ±0.011 °C
1523/24 Reference Thermometer deliver • Thermocouples: ±0.24 °C for J,K,L,M
high accuracy, wide measurement • Precision thermistors: ±0.002 °C
range, logging, and trending, all in a
handheld tool you can take anywhere. Fast measurement
For top accuracy, a memory chip inside • PRTs: up to 0.45 seconds/sample
the probe connector feeds probe • Thermocouples: up to 0.3 seconds/
calibration information to the readout. sample
In addition, any thermocouple with • Precision thermistors: up to 0.3
a mini-thermocouple connector can seconds/sample
be read using the optional universal
thermocouple adapter. Choose the 1523 Two models
for single channel or the 1524 for dual • 1523: Single channel standard model;
channel measurement. memory for 25 readings & statistics
• 1524: Two channels; memory for 25
Three sensor types readings and statistics plus logging
• PRTs: –200 °C to 1000 °C 15,000 measurements; real-time clock
• Thermocouples –200 °C to 2315 °C for time and date stamps
Fluke 1524 Fluke 1523 • Precision thermistors: –50 °C to 150 °C
Features
1523 1524
Note: The 1523/24 are pictured with probes connected which may
be purchased seperately. Sensor Types PRT & RTD, Thermistor, and Thermocouple
Thermocouple Types B,C,E,J,K,L,M,N,R,S,T,U
Number of inputs Single Dual
Data trending (graphing) O O
Graphical display with backlight O O
Included Accessories Min/Max/Avg/Standard deviation recording O O
NIST traceable certificate of calibration, users High speed measurement O O
guide, CD-ROM (contains technical manual), RS-232 PC communications O O
12 V dc universal power supply, RS-232 cable, T1-T2 True differential O
9940 I/O ToolKit software Data logging up to 15,000 points O
Time and date stamp O
Ordering Information
Fluke 1523* Reference Thermometer
Fluke 1524* Reference Thermometer
Fluke 1523-P1 Reference Thermometer, Specifications
PRT(–200 °C to 420 °C, 6.35
mm x 298 mm), Universal (Check the Fluke web for detailed specifications)
Thermocouple Adapter, TPAK,
Temperature range
and Case
Thermocouple –200 °C to 2315 °C
Fluke 1524-P1 Reference Thermometer, PRT & RTD –200 °C to 1000 °C
PRT(–200 °C to 420 °C, 6.35 Thermistor –50 °C to 150 °C
mm x 298 mm), Universal Resolution and best accuracy
Thermocouple Adapter, TPAK, Thermocouple 0.01 °, ±0.24 °C
and Case PRT & RTD 0.001 °, ±0.011 °C
Thermistor 0.001 °, ±0.002 °C
* Requires an optional probe Operating temperature –10 °C to 60 °C
Storage temperature –20 °C to 70 °C
Optional Accessories
2384-P INFO-CON Connector, PRT
Battery life (alkaline): 20 hours
(Gray Cap), Spare Power supply: Universal 12 Vdc
2384-T INFO-CON Connector, Size (HxWxD): 200 x 96 x 47 mm
Thermocouple (Blue Cap), Weight: 0.65 kg
Spare Warranty: 1 year
2373-LPRT RTD Adapter, Lemo to
Mini Grabbers (4-wire)
57
Ti Series Thermal Imagers
www.fluke.eu/ti
SmartView® Software
Fluke SmartView® software is included with each Fluke
Thermal Imager. This powerful software is a modular
suite of tools that annotates, views, edits and analyzes
IR images.
Overheated motor Cool corner in a building It also generates fully customizable and professional-
looking reports in a few easy steps. The IR-Fusion
technology is fully supported.
Thermal imaging
application video
This video covers the principles of thermal
imaging and looks at using this powerful
troubleshooting technology in electrical,
electro-mechanical and process control
applications. Go to www.fluke.co.uk/ti or
www.fluke.eu/ti to see the video. FREE webinars/webcasts on
Thermal Imaging
Keep up-to-date on the latest troubleshooting
techniques. Attend a FREE Fluke webinar (web-based
seminar) about thermal imaging applications.
Go to www.fluke.eu/ti for more information.
58
CRange IRWindows
Specifications
(Check the Fluke web for detailed specifications)
FLK-075-CLKT FLK-100-CLKT
Optic Data
Crystal Insert Diameter 75 mm 100 mm
Viewing Aperture Diameter 68 mm 89 mm
Viewing Aperture Area 3632 mm2 6322 mm2
Thickness 2 mm 4 mm
CLIRVU Coating O O
Shortwave IR Capable O O
Midwave IR Capable O O
Longwave IR Capable O O
Ultraviolet (UV) Capable O O
Visual Capable O O
Fusion Capable O O
General
Maximum Temperature
Gaskets 250º C
Body 659 º C
Included Accessories Optic 1400º C
Installation CD, self-adhesive drilling Gaskets Low Smoke & Fume (LSF) compliant silicone
template, security access key, warranty IP rating IP65
NEMA rating Typo 3/12 (UL & CSA Third Party Certified)
statement.
Vibration rating IEC60068-2-6
Humidity rating IEC60068-2-3
Ordering Information Pull out strength Up to 630 kg
59
Ti9/Ti10
Electrical Thermal Imagers
Specifications
(Check the Fluke web for detailed specifications)
Included Accessories
SmartView® software
2 GB SD card Battery life: 3 to 4 hours continuous operation
SD card reader Water and dust resistant: IP54
Rugged hard carrying case Size (HxWxD): 267 x 127 x 152 mm
Weight: 1.2 kg
Soft carrying case
Two Years Warranty
Hand strap
Rechargeable battery
AC charger/power supply Recommended Accessories
User manual
Training DVD
Ordering Information
Fluke Ti9 Electrical Thermal Imager Ti-Visor Ti-Car Charger Ti-TRIPOD
Tripod Mounting Base
Sun Visor Car charger
Fluke Ti10 Thermal Imager (for complete Ti Series) Accessories
60 (for complete Ti Series)
Ti25/Ti32
Industrial Thermal Imagers
Specifications
Fluke Ti32
(Check the Fluke web for detailed specifications)
Included Accessories
SmartView® software Water and dust resistant: IP54
2 GB SD card Size (HxWxD): Ti25: 267 x 127 x 152 mm
SD card reader Ti32: 277 x 122 x 170 mm
Rugged hard carrying case Weight: Ti25: 1.2 kg
Soft carrying case Ti32: 1.05 kg
Hand strap Two Years Warranty
Rechargeable battery
AC charger/power supply Recommended Accessories
User manual
Training DVD
Ordering Information
Fluke Ti25 Industrial Thermal Imager FLK-LENS/TELE1 FLK/LENS/WIDE Ti-Car Charger FLK-TI-SPB3 FLK-TI-SBC3
Fluke Ti32 Industrial Thermal Imager Telephoto Infrared Lens Wide-angle Infrared Lens Car charger Extra battery (Ti32) Charging base (Ti32)
(Ti32) (Ti32) 61
TiRx/TiR
Thermal Imagers
for Building Inspection
Specifications
(Check the Fluke web for detailed specifications)
Included Accessories
SmartView® software Water and dust resistant: IP54
2 GB SD card Size (HxWxD): 267 x 127 x 152 mm
SD card reader Weight: 1.2 kg
Rugged hard carrying case Two Years Warranty
Soft carrying case
Hand strap
Rechargeable battery
AC charger/power supply Recommended Accessories
User manual
Training DVD
Ordering Information
Fluke TiRx Inspector Thermal Imager Ti-Visor Ti-Car Charger Ti-TRIPOD
Fluke TiR Thermal Imager Sun Visor Car charger Tripod Mounting Base
62 (for complete Ti Series) Accessories
(for complete Ti Series)
TiR1/TiR32
Thermal Imagers
for Building Diagnostics
New
The top professional’s choice
The TiR1 and TiR32 Thermal Imagers are TiR32 to identify even small temperature
the top professional’s choice for building differences that could indicate problems.
diagnostics. With its 320 x 240 sensor, For added versatility and special
the TiR32 delivers the clear, crisp images applications, the TiR32 includes dewpoint
needed to find problems fast. The Fluke measurements and two field-swappable,
TiR1 and TiR32 have all the features rechargeable batteries. Use the optional
of the Fluke TiR, but with an NETD of telephoto and wide-angle lens to bring
0.07ºC for the TiR1 and 0.05ºC for the distant and wide views into sharp focus.
Fluke TiR32
Specifications
(Check the Fluke web for detailed specifications)
Included Accessories
SmartView® software Water and dust resistant: IP54
2 GB SD card Size (HxWxD): TiR1: 267 x 127 x 152 mm
SD card reader TiR32: 277 x 122 x 170 mm
Rugged hard carrying case Weight: TiR1: 1.2 kg
Soft carrying case TiR32: 1.05 kg
Hand strap Two Years Warranty
Rechargeable battery
AC charger/power supply Recommended Accessories
User manual
Training DVD
Ordering Information
Fluke TiR1 Thermal Imager for Building
Diagnostics FLK-LENS/TELE1 FLK/LENS/WIDE Ti-Car Charger FLK-TI-SPB3 FLK-TI-SBC3
Fluke TiR32 Thermal Imager for Building Telephoto Infrared Lens Wide-angle Infrared Lens Car charger Extra battery (Ti32) Charging base (Ti32)
Diagnostics (Ti32) (Ti32) 63
Laser Distance Meters
The Fluke Laser Distance Meters bring you the most advanced
measuring technology. Unlike ultrasonic distance meters with laser
pointers, these meters use a precision narrow laser beam that can
avoid the common errors caused by extraneous objects near
measurement targets.
64
421D, 416D, 411D
Laser Distance Meters
Specifications
(Check the Fluke web for detailed specifications)
Ordering Information
Fluke 411D Laser Distance Meter
Fluke 416D Laser Distance Meter
Fluke 421D Laser Distance Meter 65
Indoor Air Quality Tools
66
975 AirMeter
Specifications
(Check the Fluke web for detailed specifications)
General Specifications
General specifications
Operating Temperature 0 ºC to +50 ºC
Storage Temperature -40 ºC to +60 ºC
Operating Relative Humidity Non condensing (<10 ºC)
90% RH (10 ºC to 30 ºC)
75% RH (30 ºC to 40 ºC)
45% RH (40 ºC to 50 ºC) Without Condensation
IP Rating IP40
Operating Altitude 2000 m
Storage Altitude 12000 m
EMI, RFI, EMC Meets requirements for EN61326-1
Vibration MIL-PREF-28800F, Class 3
Max Pressure at Each Port 10 PSI
PT12 TPAK
Pitot Tube, 30.48 cm Toolpak
See page 120
68
971 Temperature Humidity Meter
Carbon Monoxide Meters
Fluke 971
Temperature Humidity Meter
Quickly take accurate humidity and • Simultaneously measures humidity and
temperature readings in the air. temperature
Temperature and humidity are two • Measures dew point and wet bulb
important factors in maintaining • 99 record storage capacity
optimal comfort levels and good indoor • Min/Max/Avg Data Hold
air quality. The Fluke 971 is invaluable • Ergonomic design with built-in belt clip
for facility maintenance and utility and protective holster
technicians, HVAC-service contractors, • Backlit, dual readings display
and specialists who assess indoor air • Twist-open protective cap
quality (IAQ). Lightweight, rugged, and • Low battery indicator
easy to hold, the Fluke 971 is the perfect
tool for monitoring problem areas.
Specifications
69
983 Particle Counter /
RLD2 Leak Detector Flashlight
Specifications
70
ScopeMeter® Test Tools
71
ScopeMeter® Test Tools
Features
225C 215C 199C 196C 192C 125 124 123
LDC Display Color B/W
Persistence O O O O O
Waveform reference O O O O O
Automatic pass fail testing O O O O O
Cursors and zoom O O O O O Cursors
Connect and View triggering O O O O O O O O
Video triggering with line selector O O O O O O O O
Selectable pulse width triggering O O O O O
Capture and replay of last 100 screens O O O O O
Dual input TrendPlot With cursors and Zoom O O O
Memory for screens and set-ups 10 screens and setup 20 20 10
Recorder memories, each can store 100 scope screens, 2 recorder memories
a ScopeRecord or a TrendPlot
The ScopeMeter 190C Series of high 1000V Independently floating isolated outputs O O O O O
performance oscilloscopes have Meter measurements: VAC RMS, VAC+DC, Ohms,
Continuity, Diode, Amps, Temp. (ºC, ºF)
O O O O O O O O
bandwidth of 60, 100 and 200 MHz and
Waveform mathematics: A+B, A-B, AxB, A versus B O O O O O
sample rates up to 2.5 GS/s. (X-Y mode)
These instruments offer a high- Frequency Spectrum Analysis using FFT O O O O O 2)
Three-in-one simplicity
The compact ScopeMeter 120 Series stable, reliable and repeatable display
is the rugged solution for industrial of virtually any signal - including
troubleshooting and installation motordrive and control signals - without
applications. It’s a truly integrated test touching a button. Signal changes
tool, with oscilloscope, multimeter and are instantly recognized and settings
“paperless” recorder in one affordable, adjusted for - once again - a stable
easy-to-use instrument. Find answers to display.
problems in machinery, instrumentation,
control and power systems quickly and Use TrendPlot™ to help find
easily. intermittents fast
The toughest faults to find are those
• Dual-input 40 MHz or 20 MHz digital that happen only once in a while:
oscilloscope intermittents. They can be caused by
Fluke 125 • Two 5,000 counts true-RMS digital bad connections, dust, dirt, corrosion
multimeters or simply broken wiring or connectors.
• A dual-input TrendPlot™ recorder You may not be around to see it – your
• Bus Health Test for industrial bus Fluke ScopeMeter will. In this “paperless
systems (Fluke 125) recorder” mode,
• Connect-and-View™ trigger simplicity you can plot the minimum and
for hands-off operation maximum peak values and average over
• Power Measurements and Harmonics time – up to 22 days (Fluke 190 Series) or
measurement (Fluke 125) 16 days (Fluke 120 Series).
• Shielded test leads for oscilloscope,
resistance and continuity Bus Health mode (Fluke 125)
Fluke 124
measurements Bus Health mode gives a clear “Good/
• Up to 7 hours battery operation Bad” indication for the electrical signals
• 600 V CAT III safety certified on industrial buses and networks, such
• Optically isolated interface for PC and as CAN-bus, Profi-bus, RS-232 and many
Printer connection (optional) more. The Fluke 125 validates the quality
• Rugged, compact case of the electrical signals as soon as any
electrical signals are passed along the
Connect-and-View™ triggering for network.
Fluke 123 an instant, stable display
Scope users know how difficult triggering
can be. Wrong settings show unstable
and sometimes wrong results. Fluke’s
unique Connect-and-View recognizes
signal patterns, and automatically
True RMS sets up correct triggering. It provides a
Included Accessories
PM 8907 line adapter/charger, STL120 shielded
test leads set (1 red, 1 grey), AC120 Alligator
Clips, BB120 shielded BNC adapter, BP120MH
NiMH battery pack, VPS40 wide bandwidth
Voltage Probe (Fluke 124/125), TL75 hard
point test lead, i400s current clamp (Fluke
125), Getting Started booklet, user’s manual
(cd-rom)
Ordering Information
Fluke 123 Industrial ScopeMeter® (20MHz)
Fluke 123/S Industrial ScopeMeter® (20MHz)
Connect-and-View captures even the most Bus Health mode allows for an analysis of the
+ SCC120 kit complex motor drive signals. signal quality on an industrial network.
Fluke 124 Industrial ScopeMeter® (40MHz)
Fluke 124/S Industrial ScopeMeter® (40MHz)
+ SCC120 kit
Fluke 125 Industrial ScopeMeter (40 MHz) See page 72 for specifications.
Fluke 125/S Industrial ScopeMeter (40 MHz) +
SCC120 kit Recommended Accessories
SCC120 FlukeView® Software + OC4USB
Cable + Carrying Case
OC4USB USB Interface Cable
PM9080 RS-232 Interface Cable
DP120 Differential Voltage Probe
ITP120 Isolated Trigger Probe SCC120 C125 DP120 OC4USB SCC128
See page 118 See page 76 See page 76 See page 113
SW90W FlukeView Software
BHT190 Set of 3 break-out adapters 73
(Fluke 125)
ScopeMeter® 190C Series
(incl. 225C and 215C)
• Dual input – 60, 100 or 200 MHz models Bus Health Test (225C and 215C)
• Up to 2.5 GS/s real time sampling per input Bus Health Test analyses the electrical
• Bus Health Test capability for industrial signals on an industrial bus or network
buses, including Profi, Foundation, ModBus and gives a clear “Good”, “Weak” or “Bad”
and many more (225C and 215C) validation mark for each of the relevant
• High resolution color display parameters, presented next to the actual
• High waveform resolution of max. 3000 measurement value.
datapoints per channel The Fluke 225C and 215C can make the
• Digital Persistence for analyzing complex signal quality validation as soon as electrical
dynamic waveforms like on an analog signals are passed along the network,
scope without looking at the data content. They
Fluke 199C • Fast display update rate (> 100/sec) for find errors like improper cable connections,
seeing dynamic behavior instantaneously bad contacts, incorrect grounding and
• Connect&View™ automatic triggering, missing or superfluous terminators.
a full range of manual triggering modes
plus external triggering.
• Automatic capture and replay of
100 screens
• 27500 points per input record length using
ScopeRecord mode
• Up to 1000 V independently floating
isolated inputs
• Waveform reference for visual
comparisons and automatic pass/fail
testing of waveforms
• Vpwm function for motor drive and
frequency inverter applications.
• Waveform mathematics: Add, Subtract and
Fluke 196C Fluke 192C Multiply
• Frequency Spectrum Analysis using FFT
• X-vs-Y mode (Lissajous display) for study
of signal relationships
• Cursors, zoom and real-time clock
• 30 automatic waveform measurements
• Over 3.5 hours rechargeable Ni-MH battery Automatic capture and replay
pack of 100 screens
• Includes a 5000 count true-RMS Scope users know how frustrating it is to
multimeter and a TrendPlot™ paperless see a one time anomaly flash by, never to be
recorder seen again. Not with the ScopeMeter 190C
Series! Now you can look back in time with
ScopeMeter for medical imaging and a touch of the replay button. In normal use,
video test applications the instrument continuously memorizes
For tests on such systems, an optional the last 100 screens. Each time a new
Fluke 225C Fluke 215C configuration is available. Please check the screen is acquired, the oldest is discarded.
Fluke website for further details. At any moment you can “freeze” the last
100 screens and scroll through picture-
by-picture or replay as a ‘live’ animation.
Cursors can be used for further analysis.
You can even use the advanced trigger
capabilities to capture up to 100 specific
events. Two sets of 100 captured screens
with individual time stamps can be stored
True RMS for later recall or download to a PC.
On all inputs
74
ScopeMeter® 190C Series
(incl. 225C and 215C)
See dynamic signal Frequency Spectrum Analysis 190C FlukeView® Software for documenting,
behavior instantaneously All 190C Color ScopeMeters include archiving and analysis
The Digital Persistence mode helps to find Frequency Spectrum Analysis on Fast Fourier FlukeView® for Windows® helps you get more
anomalies and to analyze complex dynamic Transformation (FFT) analysis as a standard out of your ScopeMeter by:
signals by showing the waveforms amplitude feature. • Documenting - transfer waveforms,
distribution over time using multiple This makes it possible to identify the screens and measurement data from the
intensity levels and user selectable decay individual frequency components contained ScopeMeter to a PC. Print or import the data
time - it’s as if you’re looking at the display in a signal. The spectrum analysis function is into your report
of an analog, real time oscilloscope! A fast also handy to reveal the effects of vibration, • Archiving - create a library of waveforms
display update rate reveals signal changes signal interference or crosstalk. An automatic with your comments for easy reference and
instantaneously, useful for instance when window function assures optimal windowing, comparison
making adjustments to a system under test. although you may manually select your • Analysis - use cursors, perform spectrum
preferred time window. analysis or export data to other analysis
programs
Pulse width fluctuations are clearly visible using Digital Frequency Spectrum shows an overview of frequencies FlukeView Screen
Persistence contained in a signal.
Included Accessories
BC190 Battery Charger
BHT190 Set of 3 break-out adapters
(225C/215C)
BP190 NiMH Battery Pack
VPS210-G + VPS210-R Voltage Probe
TL75 Hard Point Test Lead Set
user’s manual (CD-Rom), Getting Started
Booklet
Ordering Information
Fluke 192C Color ScopeMeter
(60 MHz, 500 MS/s)
Fluke 196C Color ScopeMeter
(100 MHz, 1 GS/s) Thanks to the deep memory, very small parts of the waveform can be studied in full detail
Fluke 199C Color ScopeMeter using “zoom”.
(200 MHz, 2.5 GS/s)
Fluke 215C Color ScopeMeter with Bus
Health Test (100 MHz, 1 GS/s)
Fluke 225C Color ScopeMeter with Bus See page 72 for specifications.
Health Test
(200 MHz, 2.5 GS/s)
Fluke 192C/S 192C + SCC191 kit option
Fluke 196C/S 196C + SCC191 kit option
Fluke 199C/S 199C + SCC191 kit option
Fluke 215C/S 215C + SCC191 kit option Recommended Accessories
Fluke 225C/S 225C + SCC191 kit option
SCC190 SW90W FlukeView Software,
OC4USB cable, C190 briefcase
style carrying case
SCC191 SW901W FlukeView Software,
OC4USB cable, industrial style
carrying case ScopeMeter SCC191 Scopemeter SCC190 C195 OC4USB SCC198
See page 118 See page 76 See page 113
C190 Briefcase style carrying case 75
SW90W FlukeView Software
ScopeMeter® Accessories
ScopeMeter probes
VPS40 VPS210-R VPS210-G VPS212-R VP212-G VPS220-R VPS220-G VPS101 DP120 PM8918/301
Description Voltage Voltage Probe Set Voltage Probe Set Voltage Probe Set Voltage Probe Differential Low Pass
Probe Set Set Probe Set Filter Probe
Number and color One Black 1 Red 1 Grey 1 Red 1 Grey 1 Red 1 Grey 1 Black Red & Grey One Blue
Attenuation 10:1 10:1 10:1 100:1 1:1 200:1, 20:1 10:1
Bandwidth DC-MHz 40 200 MHz 200 MHz 200 MHz 30 MHz 20 4 kHz
Length (m) 1.2 1.2 m 2.5 m 1.2 m 1.2 m 1.5 2.5
EN 61010-2 CAT II 1000 V 1000 V 1000 V 1000 V - 1000 V -
EN 61010-2 CAT III 600 V 600 V 600 V 600 V 300 V 600 V 600 V
ScopeMeter 190 Series O O O O O O O O O
ScopeMeter 120 Series O O O O1) O1)
1) Using BB 120
RS200 Probe Accessory Replacement Set for VPS Series Probes Battery Packs
AS200-R Probe Accessory Set, Red for VPS Series Probes BP120MH NiMH Battery Pack for 120 Series + 43B
AS200-G Probe Accessory Set, Grey for VPS Series Probes BP190 NiMH Battery Pack for 190 + 430 Series
PM9080 Optical Interface Adapter Cable for serial port
OC4USB Optical Interface Adapter Cable for USB Port
PM9090 Probe Pin Grabber Flexible Clip for VPS Series Probes
PM9094 Mini Testhook Set for PM8918 Probes
PAC91 Printer Adapter Cable
76
All accessories have a one year warranty
Power Quality Tools and Power
Analyzers
77
78
Power quality tools help pinpoint problems fast
PowerLog To make use of the power data you collect, you need O O O O
PQLog software that can help analyze your findings and share O
them with equipment providers and plant management.
Power Analyze O
PQ Analyze O
FlukeView Forms O
VIDEO
Power Quality in Industrial Applications
Covers the basics of power quality and looks at the tools and inspection techniques
used to troubleshoot common problems.
Applications
• Voltage recording – Monitors and • Flicker measurement – Quantify the
records supply voltage; measures RMS affects of switching loads on lighting
average, minimum and maximum systems.
values, and checks whether the socket • Voltage transients – Capture those
outlet is providing voltage within intermittent, momentary events that
tolerance. may be affecting your equipment; the
• Distortion measurement – Measure full waveform is captured with date,
frequency and harmonics; check timestamp, and duration.
whether the distorting loads (UPS
systems, drives, etc.) are affecting your
other equipment.
PowerLog Setup – Simple set up of Actual transient display Statistical analysis of voltage event
internal clock, logging periods, and (> 100 μs) with time stamp– – reduces analysis time by tracking
intervals with default values for Quickly identify issues with included event quantities and magnitudes.
quick results. graphical software.
PowerLog View – Data presentation
showing RMS voltage and harmonic
trends, actual transients, summary
information and statistics in
accordance with EN50160.
Specifications
(Check the Fluke web for detailed specifications)
Ordering Information
Fluke VR1710 Voltage Quality Recorder Display: LED Weight: 0.8 kg
Size (HxWxD): 23 x 19.75 x 22.2 cm Two years warranty 79
345
Power Quality Clamp Meter
Specifications
Fluke 345 (Check the Fluke web for detailed specifications)
Current measurement
DC, DC rms, AC rms All measurements DC and 15 Hz to 1 kHz.
Maximum overload 10,000 A or RMS x frequency < 400,000. Amps rms is a true rms
measurement (AC + DC).
Measuring range 0 – 2000 A dc or 1400 AC rms
Harmonics All measurements up to 30th harmonic (40th harmonic for 15 Hz to 22 Hz); Frequency
range F0 : 15 Hz to 22 Hz and 45 Hz to 65 Hz; Iacrms > 10A
Voltage measurement
DC, DC rms, AC rms All measurements DC and 15 Hz to 1 kHz. Maximum overload 1,000 V rms. Volts rms is a
true-rms measurement (AC + DC).
Measuring range 0 – 825 V DC or AC rms
Harmonics All measurements up to 30th harmonic; Frequency range F0 : 15 Hz to 22 Hz and 45 Hz
to 65 Hz; Vacrms > 1V
Watts measurement (single- and three-phase) DC, DC rms, AC rms
Measuring range 0 – 1650 kW DC or 1200 kW ac
VA measurement (single- and three-phase) DC, DC rms, AC rms
View waveforms for equipment Measuring range 0 -1650 kVA DC or 1200 kVA ac
checking and setup VAR measurement (single- and three-phase)
Measuring range 0 – 1250 kVAR
Power factor (single- and three-phase)
Measuring range 0.3 cap…1.0… 0.3 ind (72.5° cap…0°… 72.5° ind)
Displacement power factor
Measuring range 0.3 cap … 1.0 … 0.3 ind (72.5° cap ... 0° ... 72.5° ind)
Kilowatt Hour (kWHr)
Measuring range 40,000 kWHr
Scope function
Time base 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms/div
Current management:
Ranges 10 A/20 A/40 A/100 A; 200 A/400 A/1000 A/2000 A
Voltage measurement:
Ranges 4 V/10 V/20 V/40 V/100 V; 200 V/400 V/1000 V
Inrush current function All measurements dc and 15 Hz to 1 kHz
Ranges 40, 400 and 2000 A
Log parameters over time Memory Up to 50 screen shots and over 150,000 individual measurement values
to track down intermittent faults
Power supply: 1.5 V Alkaline AA MN 1500 or IEC LR6 Display: Color transmissive LCD 320 x 240 pixels
x 6 Battery (70 mm diagonal) with 2 level backlight
Battery life (typical): >10 hours (backlight on full); Digital output: USB interface to a PC
>12 hours (backlight reduced) Size (HxWxD): 300 mm x 98 mm x 52 mm
Safety: IEC 61010-1 600 V CAT IV, 1000V CAT III Jaw opening: 60 mm
(maximum input phase-phase 825V rms) double or Jaw capacity: 58 mm diameter
reinforced insulation, pollution degree 2 Weight (including batteries): 0.82 kg
Protection: IP40; EN60529 Two Year Warranty
Operating temperature: 0 °C to 50 °C
Included Accessories
Soft carrying case, Power Log software,
Test probes, Test leads, Alligator clips,
International ac adapter / battery eliminator,
Printed English User manual, Multi-language Recommended Accessories
manual on CD
Ordering Information
Fluke 345 Power Quality Clamp Meter
Specifications
(Check the Fluke web for detailed specifications)
Ordening information
Fluke 43B Power Quality Analyzer Recommended Accessories
(single-phase)
Logging function allows you to customize measurement Measure and record power (W), VA and VARs. Track harmonics up to the 50th, and measure and record
selections and provides instantaneous analysis of user- The 434 and 435 add the ability to record energy THD in accordance with IEC61000-4-7 requirements
selectable parameters. consumption.
Specifications
(Check the Fluke web for detailed specifications)
Ordering information
Fluke 435/Basic Power Quality Analyzer 1
depending clamp scaling
(three phase) 2
Value is measured over 1 cycle, commencing at a fundamental zero crossing, and refreshed each half-cycle
Quantify energy
consumption quickly
on-screen or log to Capture voltage events
memory for extended using user-defined
periods. thresholds.
General
Memory 4 MB Flash memory, 3.5 MB for measuring data
Sample rate 10.24 kHz
Line frequency 50 Hz or 60 Hz, user-selectable, with automatic synchronization
Display: VGA Graphic Color transmissive displays Power supply: NiMH battery-pack, with AC adapter
320 x 240 pixels with additional background lighting (15 V to 20 V/0.8 A)
and adjustable contrast, text and graphics in color Battery Life: Typical > 16 hours without backlight and
Included Accessories Interface: RS-232 SUB-D socket; 115.2 k Baud, > 6 hours with backlight high
8 data bits, no parity, 1 stop bit, firmware updates are Operating temperature: 0°C to +40°C
FS17XX 4-phase flexible current clamp set, possible with the RS-232 interface (9-pole extension Size (HxWxD): 240 mm x 180 mm x 110 mm
VL1735/1745 voltage lead set, Power Log cable) Weight: 1.7 kg, including battery
Housing: IP65; EN60529 (refers only to the main Two Year Warranty
software, color localization set, PC interface housing without the battery compartment)
cable, international ac adapter, BC1735 battery
charger, soft carrying case, printed English
manual and multi-language manual on CD.
Ordering Information Power supply: 88 V … 660 V AC Size: Fluke 1745: 282 mm x 216 mm x 74 mm;
Safety: IEC/EN 61010-1 600 V CAT III, 300 V Fluke 1743/44: 170 mm x 125 mm x 55 mm
Fluke 1743 Basic Power Quality Logger CAT IV, pollution degree 2, double insulation Weight: Fluke 1745 – approx. 3 kg;
Memobox Housing: Fully insulated housing and accessories Fluke 1743/44: approx. 2 kg
Operating temperature: 0 °C to 35°C Two Year Warranty
Fluke 1743 Power Quality Logger Interface: RS 232, 9600 ... 115 000 Baud, automatic
Memobox Baud rate selection, 3-wire communication
Fluke 1744 Basic Power Quality Logger
Memobox
Fluke 1744 Power Quality Logger
Memobox
Fluke 1745 Power Quality Logger
Memobox
Specifications
(Check the Fluke web for detailed specifications)
Features
(Check the Fluke web for detailed specifications)
Descript ion 3 ... phase 4 ... phase 3 ... phase 4 ... phase 3 ... phase 4 ... phase 4 Phase flexiset, 4 Phase flexiset, 4 ... phase Single phase 4 ... phase 3 ... phase 5A
1A/10A Mini 1A/10A Mini 5A/50A Mini 5A/50A Mini 20A/200A 20A/2000A IP41 IP65 3000A Flexible 400A current 3000A Current clamp
current clamp current clamp current clamp current clamp Mini current Mini current current clamp clamp Flexible set
set set set set clamp set clamp set set (4 required) current clamp
set
Old Fluke model # CURRENT MBX CLAMP MBX CLAMP MBX CLAMP MBX CLAMP MBX CLAMP MBX Lem Flex MBX Lem Flex
CLMAPS 1A 1A/10A+N 5A/50A 5A/50A+N 20A/200A 20/2000A+N (15/150/3000) (15/150/3000)
(EPO450A) (EPO451A) (EPO452A) (EPO453A) (EPO455A) (EPO456A) (EP0404A) (EP0404A)
Fluke 1735 O O O O O O O O
Fluke 174X O O O O O O O O
Fluke 43X O O O O
Nominal current range(s) 1A 1A 5A 5A 20 A 20 A 15A 150A 1500A 15A 150A 1500A 30 A 40 A 3000 A 5A
10 A AC 10 A AC 50 A AC 50 A AC 200 A AC 200 A AC 3000A AC 3000A AC 300 A 400 A
3000 A
Cont. AC current range 10 mA ... 1 A 10 mA ... 1 A 50 mA ... 5 A 50 mA ... 5A 200 mA ... 200 mA ... 450mA … 15A 450mA … 15A 1 A ... 30 A 0.5 A ... 40 A 30 A ... 3000 A 0.01 A ... 6 A
100 mA ... 10 A 100 mA ... 500 mA ... 500 mA ... 20 A 20 A 600mA… 150A 600mA… 150A 1 A ... 300 A 5 A ... 400 A
10 A 50 A 50 A 2 A ... 200 A 2 A ... 200 A 6A… 1500A 6A… 1500A 1 A ... 2400 A
12A… 3000A 12A… 3000A
Highest current 20 A 20 A 100 A 100 A 300 A 300 A 3300 A 3300 A 4000 A 1000 A 100 kA 70 A
Lowest measurable current 10 mA 10 mA 50 mA 50 mA 200 mA 200 mA 450 mA 450 mA 1A 0.5 A 30 A 10 mA
Basic accuracy (48 ... 65 Hz) 1) 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 2%+2% position 2%+2% position 2% + 2 A 2% + 0.15 A 1% 1%
influence influence
Usable frequency 40 Hz ... 10 kHz 40 Hz ... 10 40 Hz ... 10 40 Hz ... 10 40 Hz ... 10 40 Hz ... 10 40Hz …5kHz 40Hz …5kHz 10 Hz ... 100 45 Hz ... 3 kHz 10 Hz ... 7 kHz 40 Hz ... 5 kHz
kHz kHz kHz kHz kHz kHz
Requires battery O
Flex head length 61 cm 61 cm Clamp 61 cm Clamp
opening: opening:
32 mm 15 mm
Output level(s) 75 mV/A 75 mV/A 15 mV/A 15 mV/A 3.75 mV/A 3.75 mV/A 0.1 mV/A 0.1 mV/A 10 mV/A 10 mV/A 0.085 mV/A 400 mV/A
1 mV/A 1 mV/A @50 Hz
0.1 mV/A
Output cable (m) 2 2 2 2 2 2 2 2 2.1 2.5 2.5 2.5
Safety rating CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 1000 V CAT III 1000 V CAT III 600 V CAT III 1000 V CAT III 1000 V CAT III 600 V
CAT IV 600V CAT IV 600V CAT IV 600 V CAT IV 600 V
Connection One connector One connector One connector One connector One connector One connector One connector One connector 4 x BNC 4 x BNC 4 x BNC 3 x BNC
BNC to banana adapters included n/a n/a n/a n/a n/a n/a n/a n/a O
1
Basic accuracy: % reading plus floorspec.
n/a = not applicable
Power Quality Current Clamps
Specifications
Fluke Norma 5000 (Check the Fluke web for detailed specifications)
89
Norma 4000/5000
Power Analyzer Accessories
Power Phases
The Fluke Norma 4000 Power Analyzer Each plug-in power phase consists of
can be equipped with up to three power a voltage and a current measurement
phases and the Fluke Norma 5000 Power channel. Each measuring channel is
Analyzer can be equipped with up to six available for each basic unit.
power phases. Users can select the power
phase best suited for their application.
Fluke Norma 4000 (rear view) Specifications vary depending on the model
of the power phase.
Shunts
Printer Accessories
3024650 Printer Cable for Fluke Norma 5000
(RS232-Centronics)
90
Field Calibrators
91
92
Multifunction Process
Documenting Process Calibators Temperature Calibrators Pressure Calibrators Loop Calibrators ProcessMeters
Calibrator
Model 744 743B 741B 725/725Ex 726 724 714 712 718/718Ex 717 719 715 707/707Ex 771 772 773 705 789 787
Measure
Voltage DC 300 V 300 V 300 V 30 V 30V 30 V 75 mV 10 V 28 V 30 V 28 V 1000 V 1000 V
Voltage AC (true RMS) 300 V 300 V 300 V 1000 V 1000 V
Resistance 11 kΩ 11 kΩ 11 kΩ 3200 Ω 4000 Ω 3200 Ω 3200 Ω 40 MΩ 40 MΩ
Current DC 110 mA 110 mA 110 mA 24 mA 24 mA 24 mA 24 mA 24 mA 24 mA 24 mA 24 mA 100 mA 100 mA 100 mA 24 mA 30 mA, 30 mA, 1A
1A
Current AC O O
Frequency 50 kHz 50 kHz 50 kHz 10 kHz 15 kHz 20 kHz 20 kHz
Pressure O1 O1 O1 O1 O1 68,9 mbar 68,9 mbar 2 bar to
to 20 bar / to 345 bar2 7 bar2
2 to 7 bar2
Temperature: RTD types 8 8 8 7 8 7 7
Temperature: TC types 11 11 11 12 12 12 9
Source/Simulate
Voltage DC 15 V 15 V 15 V 10 V 20 V 10 V 75 mV 10 V 10 V
Resistance 11 kΩ 11 kΩ 11 kΩ 3200 Ω 4000 Ω 3200 Ω 3200 Ω
mA DC/% scale 22 mA 22 mA 22 mA 24 mA 24 mA O 24 mA 24 mA 24 mA 24 mA 24 mA 24 mA 24 mA
mA source; auto step, auto ramp O O O O O O O O O O O O
Frequency 50 kHz 50 kHz 50 kHz 10 kHz 15 kHz
Temperature: RTD types 8 8 8 7 8 7 7
Temperature: TC types 11 11 11 10 10 10 9
Record
Min/Max O O O O O O O O
Hold O O O O O O O O O
As Found/As Left results O O O
Log data O O
Upload data to PC O O O
Remote operation O/- O
Features
Loop supply 24 V 24 V 24 V 24 V/12 V 24 V 24 V 24 V/- 24 V 24 V 24 V 24 V 24 V 24 V 24 V 24 V
Hart communication O
Integrated hand pressure pump O
Electric Pump O
Intrinsically safe (ATEX) 725Ex 718Ex 707Ex
NIST traceable certification O O O O O O O O O O O O O O
Warranty in years 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3
See catalog page 93 93 93 94 94 95 96 96 98 98 98 99 99 100 100 100 99 101 101
Selection Guide
Field Calibrator
1
Fluke 700 pressure modules required
2
Ranges for the internal sensor.
Ranges for use of Fluke 700 pressure modules, see page 102.
740 Series Documenting
Process Calibrators
Included Accessories
Fluke 741B/743B: TL224 Industrial Test Leads Specifications
(2 sets), AC220 Test Clips (2 sets), TP220 Test
Probes (1 set), BP7217 Battery Pack, BC7217 (Check the Fluke web for detailed specifications)
Battery Charger, Instruction Manual, NIST
Function Measure Sourcing
Traceable calibration certificate and data,
Voltage DC 0.025% reading + 0.005% full scale 0.01% output + 0.005% full scale
three-year warranty, serial port cable (743B Current DC 0.01% reading + 0.015% full scale 0.01% output + 0.015% full scale
only), DPC/TRACK Sample Version with free PC Resistance 0.05% reading + 50mΩ 0.01% output + 40mΩ
communication utility software (743B only). Frequency 0.05% 0.01 %
Fluke 744: TL224 Industrial Test Leads Thermocouples 0.3ºC 0.2ºC
(2 sets), AC220 Test Clips (2 sets), TP220 Test RTDs 0.3ºC 0.1ºC
Probes (1 set), BP7235 NiMH Battery Pack, Pressure To 0.05% of full scale. See Pressure Module specifications.
BC7217 Battery Charger, serial port cable,
HART communications cable, DPC/TRACK Operating temperature: -10º C to 50º C Battery Replacement: Via snap-shut door
Sample Version with free PC communication Safety: CAT II 300V without opening calibrator; no tools required
Battery Life: Typically over eight hours Weight: 1.4 kg
utility software, Instruction Manual, HART Internal Battery Pack: NiCd, 7.2V, 1700 mAh Size (HxWxD): 236 mm x 130 mm x 61 mm
Users Manual, NIST Traceable calibration Three Year Warranty
certificate and data.
Ordering Information
Fluke 725 Multifunction Process Calibrator
Fluke 725Ex Intrinsically Safe Multifunction
Process Calibrator
Fluke 726 Precision Multifunction Process C125 TL220 80PK-27 TPAK 700P27
See page 118 See page 110 See page 116 See page 120 See page 102
Calibrator
94
724 Temperature Calibrator
M = Measure S = Source/Simulate
Specifications
Function Range Resolution Accuracy Notes
Measure or Source
Voltage 0 to 100 mV 0.01 mV 0.02% Rdg + 2 LSD Max load, 1 mA
Ordering Information
Fluke 724 Temperature Calibrator
Recommended Accessories
Fluke 712
Specifications
Model Function Range Resolution Accuracy Notes
Fluke 712 Measure/ -200 to 800ºC 0.1ºC, 0.1ºF 0.33ºC, 0.6ºF Pt; 100, 200, 500,
simulate RTD (Pt 100) (Pt 100) 1000 (385);
Pt 100 (3926);
Pt 100 (3916) JIS;
Ni 120 (672)
Measure/ 15 Ω to 3200 Ω 0.1 Ω 0.1 Ω to 1 Ω
simulate
Resistance
Fluke 714 Measure/ -200 to 1800ºC, 0.1–C or ºF 0.3ºC to 10 μV 9 TC types:
simulate depending on (1ºC or ºF; BRS) J K T E R S B per NIST
Thermocouple type (K, -200 to 175 and ITS-90, L U per
1370ºC) DIN 43710 and IPTS-68
Measure/ -10 to 75 mv 0.01 mV 0.025% +
simulate mV 1 count
Ordering Information
Fluke 712 RTD Calibrator
Fluke 714 Thermocouple Calibrator
Recommended Accessories
They are quick to reach temperature set The large 152 mm (6 inch) target helps
points, yet they are stable, uniform, and eliminate errors. So whether you’re
accurate. These industrial temperature measuring from -15 ºC to 120 ºC (4180)
calibrators are perfect for performing or from 35 ºC to 500 ºC (4181) you’ll get
transmitter loop calibrations, comparison a 4:1 TUR.
calibrations, or simple checks of
thermocouple sensors. • High performance, designed for
industrial use
Adding the process option means there is • Guaranteed accuracy specifications
no need to carry additional tools into the • Excellent stability and uniformity
field. The optional built-in two-channel • Large 152 mm targets capture peripheral
readout measures resistance, voltage, and vision of IR thermometer
4–20 mA current with 24V loop power. • Portability and speed for field use -
including convenient bail handle
Fluke 4180/4181
• Lightweight, portable, and fast • Simulates individual IR thermometer
• Cool to –25 °C in 15 minutes and heat to emissivity settings
660 °C in 15 minutes • No difficult infrared calculations
• Built-in two-channel readout for PRT, • Fluke and Raytek thermometer
RTD, thermocouple, 4-20 mA current calibration points can be loaded directly
• On-board automation and into the calibrator for convenience
documentation • Calibrated in accredited infrared
• Metrology performance in accuracy, laboratory by Hart Scientific, the experts
stability, uniformity, and loading in temperature calibration
• At least 4 times more accurate than
Included Accessories most IR thermometers
914x: 9930 Interface-it Software, Report of • Calibration includes uncertainties from
Calibration, Test leads (P Version Only), surface heat loss and emissivity
6-pin DIN Connector for Reference Probe
(P Version Only)
Ordering Information
Fluke 4180 Precision Infrared
Calibrator, –15 °C to 120 °C
Fluke 4181 Precision Infrared Specifications
Calibrator, 35 °C to 500 °C
9142 9143 9144 4180 4181
Fluke 4180-CASE Carrying Case, 4180, 4181
Temp Range –25 °C to 150 °C 33 °C to 350 °C 50 °C to 660 °C –15 °C to 120 °C 35 °C to 500 °C
Fluke 4180-DCAS Carrying Case with wheels, Stability ±0.01 °C Full Range ±0.02 °C at 33 °C ±0.03 °C at 50 °C ±0.05 °C at 0 °C ±0.2 °C at 250 °C
4180, 4181 ±0.02 °C at 200 °C ±0.04 °C at 420 °C
±0.03 °C at 350 °C ±0.05 °C at 660 °C
Uniformity ±0.01 °C Full Range ±0.01 °C at 33 °C ±0.02 °C at 50 °C ±0.1 °C at 0 °C ±0.1 °C at 35 °C
Fluke 9142-X Field Metrology Well, ±0.015 °C at 200 °C ±0.05 °C at 420 °C
Low Temp ±0.02 °C at 350 °C ±0.15 °C at 660 °C
Target Size N/A N/A N/A 152.4 mm 152.4 mm
Fluke 9143-X Field Metrology Well, diameter diameter
Mid Temp Emissivity N/A N/A N/A Preset to 0.95 Preset to 0.95
Range
Fluke 9144-X Field Metrology Well, NIST YES YES YES YES YES
High Temp Accredited
Calibration
Specifications
Model Range Resolution Over Pressure
719 30G -850 mbar to 2.4 bar 0.1 mbar Over pressure 2xFS
719 100G -850 mbar to 8 bar 1 mbar Over Pressure 2xFS
718 1G -68.9 mbar to 68.9 mbar 0.001 mbar Over Pressure 5xFS
718 30G -850 mbar to 2 bar 0.1 mbar Over Pressure 2xFS
718 100G -850 mbar to 7 bar 0.1 mbar Over Pressure 2xFS
718 300G -850 mbar to 20 bar 1 mbar Over Pressure 375 PSI, 25 bar
717 1G -68.9 mbar to 68.9 mbar 0.001 mbar Over Pressure 5xFS
717 30G -850 mbar to 2 bar 0.1 mbar Over Pressure 2xFS
717 100G -850 mbar to 7 bar 0.1 mbar Over Pressure 2xFS
717 300G -850 mbar to 20 bar 1 mbar Over Pressure 375 PSI, 25 bar
717 500G 0 mbar to 34.5 bar 1 mbar Over Pressure 2xFS
Fluke 718Ex Fluke 718 717 1000G 0 mbar to 69 bar 1 mbar Over Pressure 2xFS
717 1500G 0 bar to 103.4 bar 0.01 bar Over Pressure 2xFS
717 3000G 0 bar to 207 bar 0.01 bar Over Pressure 2xFS
717 5000G 0 bar to 345 bar 0.01 bar Over Pressure 2xFS
For Fluke 717/718/719 models: Supported Pressure Units; psi, in. H 2O(4°C), in. H2O(20°C), cm
H2O(4°C), cm H2O(20°C), bar mBar, kPa, inHg, mmHg, kg/cm2
Included Accessories Functions: Zero, Min, Max, Hold, Damp functions
Fluke 717, 718, 718Ex and 719: Max. Voltage: 30 V
Yellow Holster (718Ex red holster), TL75 Test Operating temperature: -10°C to 55°C
leads, AC72 Alligator Clips, Single 9V alkaline Safety: CSA C22.2 No. 1010.1:1992
battery (two 9V batteries in 718 and 719), User EMC: EN50082-1:1992 and EN55022:1994 Class B
manual on CD ROM. Fluke 717: For use with non corrosive gasses and liquids
Fluke 718/719: For use with non corrosive gasses
719 also includes: Push fit connectors,
Translucent test hose.
717 719
Ordering Information Size (HxWxD): 201 mm x 98 mm x 52 mm Size (HxWxD): 210 mm x 87 mm x 60 mm
Fluke 719 30G Electric Pressure Calibrator Weight: 0.6 kg Weight: 0.912 kg
Three Year Warranty Three Year Warranty (Pump one year)
Fluke 719 100G Electric Pressure Calibrator
Fluke 718 1G Pressure Calibrator 718/718Ex
Fluke 718 30G Pressure Calibrator Size (HxWxD): 216 mm x 94 mm x 66 mm
Fluke 718 100G Pressure Calibrator Weight: 0.992 kg
Fluke 718 300G Pressure Calibrator Warranty: Three years
Fluke 718Ex 30G Intrinsically Safe Pressure
Calibrator
Fluke 718Ex 100G Intrinsically Safe Pressure Recommended Accessories
Calibrator
(Not for hazardous zones)
Fluke 717 1G Pressure Calibrator
Fluke 717 30G Pressure Calibrator
Fluke 717 100G Pressure Calibrator
Fluke 717 300G Pressure Calibrator
Fluke 717 500G Pressure Calibrator
Fluke 717 1000G Pressure Calibrator
C43 (718) C125 (717) TL220 700P27 700 LTP-1
Fluke 717 1500G Pressure Calibrator See page 118 See page 118 See page 110 See page 102 See page 102
98 Fluke 717 3000G Pressure Calibrator
Fluke 717 5000G Pressure Calibrator
705/707/707Ex/715
Loop Calibrators
Specifications
Functions 705/707/707 Ex 715
Voltage measurement
Range 0-28 V DC 0-200 mV, 0-20 V
Resolution 1 mV 10 μV 1 mV
Accuracy 705: 0.025% Rdg + 2 LSD 0.01% Rdg + 2 LSD
707/707Ex: 0.015% Rdg + 2 LSD
Current measurement
Range 0-24 mA 0-24 mA
Resolution 0.001 mA 0.001 mA
Accuracy 705: 0.025% Rdg + 2 LSD 0.015%
707/707Ex: 0.015% Rdg + 2 LSD
Fluke 707
Current sourcing
Range 0-20 mA or 4-20 mA1 0-20 mA or 4-20 mA1
Accuracy 705: 0.025% Rdg + 2 LSD 0.015% + 2 LSD
707/707Ex: 0.015% Rdg + 2 LSD
Drive capability 705: 1000 Ω @ 24 mA 1000 Ω @ 24 mA
Fluke 707Ex 707: 1200 Ω @ 24 mA
707Ex: 700 Ω 20 mA
Loop power while measuring mA 24 V 24 V
Voltage sourcing N/A 0-100 mV or 0-10 V
Display current and % of span Yes mA or %
Auto step, auto ramp Yes Yes
Span Check Yes Yes
1
will over-range to 24 mA
Included Accessories
Fluke 705/707: C10 Yellow Holster, TL75 Test
Leads, AC72 Alligator Clips, Single 9V alkaline
Fluke 705, 707, 707Ex 715
Maximum voltage: 30 V (28 V - 707Ex) Size (HxWxD): 201 mm x 98 mm x 52 mm
battery, Instruction Sheet Operating temperature: -10 to 55°C Weight: 0.6 kg
Safety: CSA C22.2 No. 1010.1: 1992 Battery: One 9V alkaline
Fluke 707Ex: Red Ex-holster, Fluke TL75 Test EMC: EN50082-1:1992 and EN55022: 1994 Class B Battery life: 4 to 20 hours
Leads, AC72 Alligator Clips, Single 9V alkaline Size (HxWxD): 164 mm x 75 mm x 47 mm; Three Year Warranty
battery, Instruction Sheet Weight: 0.35 kg
Battery: One 9 V alkaline
Fluke 715: Yellow Holster (H80M excl. TPAK), Battery life: 18 hours typical, at 12 mA
TL75 Test Leads and AC72 Alligator Clips, Three Year Warranty
Single 9V alkaline battery, Instruction Sheet
Ordering Information
Fluke 705 Loop Calibrator
Fluke 707 Loop Calibrator
Fluke 707Ex Intrinsically Safe Loop Calibrator
Fluke 715 Volt/mA Calibrator
Features
771 772 773
mA measure w/jaw O O O
mA measure In circuit O O
mA source O O
Fluke 772
mA sim O O
Loop power 24 V O O
DCV source 0-10 V O
100
787/789 ProcessMeters
Features
787 789
DMM and Loop Calibrator in one tool O O
Precision 1000 V, 440 mA True RMS Digital Multimeter O O
Fluke 787
DC current source and Loop Calibrator O O
24 V Loop power supply O
Min/Max / Average / Hold / Relative Modes O O
Diode Test and Continuity Beeper O O
Manual Step (100%, 25%, Coarse, Fine) plus Auto Step and Auto Ramp O O
Simultaneous mA and % of scale read-out O O
Externally accessible battery / fuses O/- O/O
HART mode setting with loop power and a built-in 250 Ω resistor O
Fluke 789 0% and 100% buttons to toggle between 4 and 20 mA sourcing for a quick span check O
Infrared I/O serial port O
Specifications
787 789
Voltage measurements
Range 0-1000 V AC or DC 0-1000 V AC or DC
Resolution 0.1 mV to 1.0 V 0.1 mV to 1.0 V
Accuracy 0.1% Rdg+1 LSD (V DC) 0.1% Rdg+1 LSD (V DC)
Current measurement
Range 0-1 A 0-30 mA 0-1 A 0-30 mA
Resolution 1 mA 0.001 mA 1 mA 0.001 mA
Accuracy 0.2%+2 LSD 0.05%+2 LSD 0.2%+2 LSD 0.05%+2 LSD
Current Sourcing
Range 0-20 mA or 4-24 mA 0-20 mA or 4-24 mA
Accuracy 0.05% of span 0.05% of span
Other specifications
Max drive capability 500 Ω 1200 Ω
True RMS Loop power N/A 24 V
Resistance measurement To 40 MΩ, 0.2%+1 LSD To 40 MΩ, 0.2%+1 LSD
Frequency To 19.999 kHz, 0.005%+1 LSD To 19.999 kHz, 0.005%+ LSD
Continuity Beeps for resistance < 100 Ω Beeps for resistance < 100 Ω
Span Check No Yes
Included Accessories
787: Yellow Holster (H80M excl. TPAK), TL75
Hard Point Test Lead Set plus AC72 Alligator Maximum voltage: 1000 V 789
Clips, one 9V battery, user manual Operating temperature: -20 to 55ºC Size (HxWxD): 203 mm x 100 mm x 50 mm
789: TL71 Test Lead Set plus AC72 Alligator Weight: 0.6 kg
Clips, four 9V AA alkaline batteries, user 787 Battery: Four AA alkaline batteries
manual and quick reference guide. Size (HxWxD): 201 mm x 98 mm x 52 mm Battery life: 14 to 140 hours typical
Weight: 0.642 kg Three Year Warranty
Battery: One 9 V alkaline
Ordering Information Battery life: 12 to 50 hours typical
Fluke 787 ProcessMeter Three Year Warranty
Fluke 789 ProcessMeter
FVF-SC2 FlukeView Forms Software
including interface cable Recommended Accessories
Model Range (approx.) Resolution Reference High side media Low side media Fitting material Max
uncertainty overpressure2)
(23 ± 3°C) (FS)
Differential
700P00 2.5 mbar 0.001 mbar 0.3 % Dry 1) Dry 316 SS 30x
700P01/700P01Ex 25 mbar 0.01 mbar 0.2 % Dry Dry 316 SS 3x
700P02 70 mbar 0.007 mbar 0.15 % Dry Dry 316 SS 3x
700P22 70 mbar 0.007 mbar 0.1 % 316 SS Dry 316 SS 3x
700P03 340 mbar 0.01 mbar 0.05 % Dry Dry 316 SS 3x
700P23 340 mbar 0.01 mbar 0.025 % 316 SS Dry 316 SS 3x
700P04 1000 mbar 0.1 mbar 0.025 % Dry Dry 316 SS 3x
700P24/700P24Ex 1001 mbar 0.1 mbar 0.025 % 316 SS Dry 316 SS 3x
Gage
700P05/700P05Ex 2 bar 0.1 mbar 0.025 % 316 SS N/A 316 SS 3x
700P06/700P06Ex 7 bar 0.7 mbar 0.025 % 316 SS N/A 316 SS 3x
700P27/700P27Ex 20 bar 1 mbar 0.025 % 316 SS N/A 316 SS 3x
700P07 34 bar 1 mbar 0.025 % 316 SS N/A 316 SS 3x
700P08 70 bar 7 mbar 0.025 % 316 SS N/A 316 SS 3x
700P09/700P09Ex 100 bar 10 mbar 0.025 % 316 SS N/A 316 SS 2x
Absolute
700PA3 340 mbar 0.01 mbar 0.05 % 316 SS N/A 316 SS 3x
700PA4/700PA4Ex 1000 mbar 0.1 mbar 0.05 % 316 SS N/A 316 SS 3x
700PA5 2 bar 0.1 mbar 0.05 % 316 SS N/A 316 SS 3x
700PA6 7 bar 0.7 mbar 0.05 % 316 SS N/A 316 SS 3x
Vacuum
700PV3 -340 mbar 0.01 mbar 0.04 % 316 SS Dry 316 SS 3x
700PV4 -1000 mbar 0.1 mbar 0.04 % 316 SS Dry 316 SS 3x
Dual
700PD2 ± 70 mbar 0.007 mbar 0.15 % 316 SS Dry 316 SS 3x
700PD3 ± 340 mbar 0.01 mbar 0.04 % 316 SS Dry 316 SS 3x
700PD4 ±1000 mbar 0.1 mbar 0.025 % 316 SS Dry 316 SS 3x
700PD5 -1000/+2000 mbar 0.1 mbar 0.025 % 316 SS N/A 316 SS 3x
700PD6 -1000 mbar/+6.9 bar 1 mbar 0.025 % 316 SS N/A 316 SS 3x
700PD7 -1000 mbar/+13.8 bar 1 mbar 0.04 % 316 SS N/A 316 SS 3x
High
700P29/700P29Ex 200 bar 0.01 bar 0.05 % C276 N/A C276 2x
700P30 340 bar 0.01 bar 0.05 % C276 N/A C276 2x
700P31 700 bar 0.07 bar 0.05 % C276 N/A C276 1.5x
1)“Dry” indicates dry air or non-corrosive gas as compatible media. “316 S S” indicates media compatible with Type 316 Stainless Steel. “C276” indicates media compatible with Hastelloy C276.
2)Maximum overpressure specification includes common mode pressure.
Other accessories
With the Fluke 810 Vibration Tester you will be able to control unplanned
downtime, prevent recurring problems, set repair priorities and manage
your resources with an entirely new approach to vibration testing. In three
quick, easy steps, the new Fluke 810 helps you locate and diagnose com-
mon mechanical problems and prioritize their repair actions. The combi-
nation of powerful algorithms and a database of real-world measurement
experience make the Fluke 810 the most advanced troubleshooting tool
for mechanical maintenance teams who need an answer now.
103
810 Vibration Tester
New
Motor diagnosis and repair in three simple steps
The Fluke 810 Vibration Tester is the Features and benefits
most advanced troubleshooting tool • On-board identification and location of
for mechanical maintenance teams the most common mechanical faults
who need an answer now. The unique (bearings, misalignment, unbalance,
diagnostic technology helps you quickly looseness) focus maintenance efforts
identify and prioritize mechanical on root cause, reducing unplanned
problems, putting the expertise of a downtime
vibration analyst in your hands. • Fault severity scale with four severity
levels help you prioritize maintenance
Use the vibration tester to: work
• Troubleshoot problem equipment and • Repair recommendations advise
understand the root cause of failure technicians on corrective action
• Survey equipment before and after • On-board context sensitive help provide
planned maintenance and confirm the real-time tips and guidance to new
Fluke 810
repair users
• Commission new equipment and • 2 GB expandable on-board memory
ensure proper installation provide enough space for your
• Provide quantifiable proof of equipment machinery’s data
condition and drive investment in • Self-test functions ensure optimal
repair or replacement performance and more time on the job
• Prioritize and plan repair activities and • Laser tachometer for accurate machine
operate more efficiently running speed promotes confident
Set-up • Anticipate equipment failures before diagnoses
they happen and take control of spare • Tri-axial accelerometer reduces
parts inventories measurement time by 2/3 over single
• Train new or less-experienced axis accelerometers
technicians and build confidence and • Viewer PC Software expands data
skill across the team storage and tracking capacity
• Color LCD display and intuitive
multilingual, icon-based user interface
Measure promote use right out of the box
Specifications
(Check the Fluke web for detailed specifications)
Diagnose
Diagnostic specifications
Standard faults Unbalance, looseness, misalignment and bearing failures
Analysis for Motors, fans, blowers, belts and chain drives, gearboxes, couplings, centrifugal pumps,
piston pumps, sliding vane pumps, propeller pumps, screw pumps, rotary thread/gear/
Language support: lobe pumps, piston compressors, centrifugal compressors, screw compressors, closed
eng, ger, fre, ita, spa, por coupled machines, spindles
Machine rotational 200 rpm to 12000 rpm
speed range
Diagnosis details Plain-text diagnosis, fault severity (slight, moderate, serious, extreme), repair details,
cited peaks, spectra
Electrical specifications
Ranging Automatic
A/D converter 4 channel, 24 bit
Usable bandwith 2 Hz to 20 kHz
Sampling 51.2 kHz
Included Accessories
Digital signal Automatically configured anti-alias filter, high-pass filter, decimation, overlapping,
Tri-axial TEDS accelerometer, accelerometer processing functions windowing, FFT, and averaging
magnet mount, accelerometer mounting Sampling rate 2.5 kHz to 50 kHz
pad kit with adhesive, accelerometer quick Dynamic range 128 dB
disconnect cable, laser tachometer and Amplitude accuracy ±0.1 dBV
storage pouch, smart battery pack with cable FFT resolution 800 lines
and adapters, shoulder strap, adjustable Spectral windows Hanning
hand strap, Viewer PC application software, Frequency units Hz, orders, cpm
mini-USB to USB cable, getting started guide, Amplitude units in/sec, mm/sec, VdB (US), VdB (Europe)
Non-volatile nemory SD micro memory card, 2 GB internal + user accessible slot for additional storage
illustrated quick reference guide, users
manual CD-ROM, instructional training CD-
ROM, hard carrying case.
The Fluke line of intrinsically safe tools is designed to meet the needs of
technicians working in and around hazardous areas. The tools are ideal
for environments in chemical plants, petro-chemical plants, oil plat-
forms, refineries and other locations where risk of explosion exists. The
products are easily recognizable from standard Fluke products by their
lighter grey colour and red holster.
105
A brief look at ATEX
Intrinsic safety is a protection standard What is “Intrinsically Safe”? this date onwards, all products sold for
employed in potentially explosive Intrinsically safe standards apply to all use in explosive atmospheres must have
atmospheres. Devices that are certified equipment that can create one or more ATEX certification and carry the distinctive
of a range of defined potential explosion symbol:
as “intrinsically safe” are designed to be
sources:
unable to release sufficient energy, by
The Fluke Ex (IS) product line
either thermal or electrical means, to cause • Electrical sparks Fluke is among the first manufacturers to
ignition of flammable material (gas, dust/ • Electrical arcs produce handheld test tools according to
particulates). • Flames the latest ATEX standards. The Fluke line of
• Hot surfaces intrinsically safe tools is designed to meet
• Static electricity the needs of technicians working in and
• Electromagnetic radiation around hazardous areas:
• Chemical reactions • Install, maintain and troubleshoot
• Mechanical impact equipment by using the new Fluke 87V Ex
• Mechanical friction Digital Multimeter
• Compression ignition • Maintain and calibrate sensors,
• Acoustic energy transmitters and control loops with the
• Ionizing radiation line of Ex field calibrators
The tools are ideal for environments
What industries are intrinsically in petro-chemical plants, oil platforms,
safe products designed for? refineries and other locations subject to risk
• Petro-chemical of explosion.
• Oil platforms and refineries Apart from having the ATEX markings, the
• Pharmaceutical visual difference between a standard Fluke
• Bulk materials (e.g. grain) tool and the corresponding Ex version is
• Mining the different grey body colour and a red,
• Pipelines conductive holster designed specifically
• Any environment where explosive gases to eliminate the potential for electrical
are present discharge.
Inside, the Fluke Ex tools have been
What is ATEX? reengineered to reduce energy avoiding
The primary intrinsically safe standard has generation of heat and electrical sparks.
been set in the European Union with the They are premium products designed for
9/94/EC Directive, commonly called ATEX ultimate safety.
(“Atmosphères Explosibles,” French for
explosive atmospheres). The stated goal of Making sense of ATEX certification
the guidelines is to “help ensure the free Fluke 707Ex is ATEX-compliant and is
movement of products in the European certified II 2 G EEx ia IIC T4— but what
Union” by “minimizing the number of exactly does that mean?
safeguard clause applications, at least those
originating from divergent interpretations
The ATEX rules have been in place as a
voluntary standard since 1 March 1996.
The rules are mandatory on electrical
and electronic equipment for use in
environments subject to explosion hazard Here a brief explanation of the ATEX
sold in the EU starting 1 July 2003. From certification designations.
106
ATEX-certified Test Tools
Fluke 87V Ex Intrinsically safe Fluke 707Ex Fast, one-handed tool for
version of the world’s most popular loop checks
multimeter The Fluke 707Ex is the ideal, stand alone
With its high performance, accuracy and tool for calibration and maintenance of 4
motor drive compatibility, the Fluke 87V to 20 mA control loops. It provides 24V loop
is the most popular industrial multimeter power while measuring mA, and lets you
around. Now Fluke has introduced a new measure and source/simulate mA with 1 μA
intrinsically safe version – the 87V Ex – for resolution.
measurements in and around hazardous • ATEX safety rating
areas. II 2G EEx ia IIC T4
The Fluke 87V Ex has all the measurement
and troubleshooting functions of the proven See also page 99
Fluke 87V. Unlike other ATEX-certified tools,
it can be used both inside and outside the
hazardous zone (ATEX Zones 1 & 2) without
compromising performance or compliance.
So there’s no need to carry different tools
Fluke 87V Ex for use in specific zones. It also has a built- Fluke 707Ex
in thermometer with TC probe, further
reducing technicians’ tool counts.
• ATEX safety rating II 2G EEx ia IIC T4 Fluke 718Ex Self-contained Pressure
• EN61010-1 CAT III 1000V/CAT IV 600V
electrical safety rating
Calibrator
The Fluke 718Ex offers a convenient,
self contained solution for pressure
See also page 17
measurements and calibration. With its
internal pressure sensor and pump, it’s
ready for immediate, stand alone use. The
pressure range can easily be extended to up
to 200 bar with any of the 8 Fluke 700PEx
Pressure Modules.
• ATEX safety rating
II IG EEx ia IIC T4
107
General Accessories
108
Electronic Test Leads,
Probes & Clips
TL910 Electronic Test Lead Set TL960 Micro-Hook Test Lead Set TP920 Test Probe Adapter Kit
• Very small 1 mm tips to access hard • 1 pair (red, black) of test leads with • Set of push-on adapters for TL71 and TL75
to reach test points multi-stacking 4 mm banana test probes
• Probe tip length up to plugs and micro-hooks • IC test adapters,
100 mm, test lead length: • Micro-hooks attach to extended probe tips,
1m component leads up to 1 mm medium alligator clips
• Included: 3 sets of diameter (max.opening
spring loaded gold tips • 90 cm long PVC insulated leads 7.6 mm)
and 2 sets of stainless steel tips • 30 V rms or 60 V DC, 15 A • CAT II 300 V, 5 A rating
• CAT IV 600 V, CAT III 1000 V,
3 A rating
TL930 Patch Cord Set (60 cm) TL970 Hook and Pincer Kit
• 1 pair (red, black) • TL940 Mini-Hook Test Lead Set
multi-stacking 4 mm banana plug • TL950 Mini-Pincer Test Lead
TP912 Replacement Tips for TL910 patch cords Set
• Replacement tips for TL910 • Nickel-plated banana • TL960 Micro-Hook Test Lead
• Five sets of gold plated and stainless plugs Set
steel tips • 61 cm long
PVC insulated leads
• 30 V rms or 60 V DC, 15 A
TL81A Deluxe Electronic Test Lead Kit
• Includes components of TL80, plus one pair
(red, black) each
modular 1 meter
TL40 Retractable Tip Test Lead Set TL932 Patch Cord Set (90 cm) long silicone test
• One pair (red, black) of test leads with • 1 pair (red, black) multi-stacking 4 mm lead, test probe,
sharp needle point tips adjustable banana plug patch cords hook-style and
to desired length from 0 to • Nickel-plated banana pinch style clip,
76 mm plugs alligator clip, IC
• Extra hard probe tips • 90 cm long probe tip adapter
to provide long service life PVC insulated leads and spade lugs
• Flexible silicone insulated test • 30 V rms or 60 V DC, 15 A • Quadfold soft
leads carrying case
• CAT II 150 V, 3 A rating, UL listed • CAT II 300 V. UL listed
TL935 Patch Cord Kit
(60, 90, 120 cm)
• 3 sets (red and black pairs) of TLK287 Electronic Master Test Lead Kit
TL940 Mini-Hook Test Lead Set multi-stacking 4 mm banana • Includes modular leads, probes (black and
• 1 pair (red, black) of test leads with multi- plug patch cords red), minigrabber/jack
stacking 4 mm banana plugs and • Nickel-plated banana plugs set, medium alligator
mini-hooks • 60 cm, 90 cm, 120 cm long PVC clips (black and red),
• Mini-hooks attach to insulated leads spade lug/banana jack
component leads up to • 30 V rms or 60 V DC, 15 A plated (set), couplers
1.5 mm diameter IEC1010 (black and red),
• 90 cm long PVC micrograbbers and
insulated leads -leads (black and red)
• 30 V rms or 60 V DC, 15 A • TL910 Electronic Test
Lead Set
• Quadfold Pouch
• CAT III 1000 V (probes only)
109
Industrial Test Leads,
Probes & Clips
TL75 Hard Point™ Test Lead Set TL222 SureGrip™ TL223 SureGrip™
• One pair (red, black) comfort grip probes Silicone Test Lead Set Electrical Test Lead Kit
with PVC insulated, test leads with • DMM test leads (red, black) • AC220 SureGrip™ Alligator Clip
right-angle shrouded banana with safety shrouded, standard Set
plugs diameter banana plugs • TP1 Slim-Reach™ Test
• Recommended for • Right angle connector on Probes (flat bladed)
general purpose both ends • TL224 SureGrip™ Silicone
measurements • Reinforced strain relief Test Lead Set
• CAT IV 600 V, CAT III 1000 V, • 1.5 meter silicone-insulated (straight to right)
10 A rating. UL listed wire resists heat & cold
• CAT IV 600 V, CAT III 1000 V,
10 A rating. UL listed TL238 SureGrip™ High Energy
Test Lead Kit
• TP238 SureGrip™ Insulated Tip Test
TL76 All-in-one Test Lead Set TL224 SureGrip™ Probes with less than 4 mm of
• One pair (red, black) 1.5 meter long Silicone Test Lead Set exposed metal (GS38) with
silicone test leads with right • DMM test leads (red, black) flexible removable finger
angle shrouded banana plug with safety shrouded, banner
• Lantern tip (removable) standard diameter banana • TP280 20 cm Test Probe
for use with European plugs Extenders
wall sockets (4 mm Ø ) • Right angle connector on one end and • TL224 SureGrip™ Silicone
• Lantern tip can be removed straight connector on the other Test Lead Set
for easy access to terminal • Reinforced strain relief
blocks (2 mm Ø) • 1.5 meter silicone-insulated wire resists
• Removable, insulated IC caps allow probing heat & cold TLK-220 EUR SureGrip™
on closely spaced leads and compliance with • CAT IV 600 V, CAT III 1000 V, 10 A rating.
GS38. Accessory Kit
UL listed • AC220 SureGrip™ Alligator
• Cat IV 600 V, CAT III 1000 V, 10 A rating,
UL listed Clip Set
• AC285 SureGrip™ Large Jaw
TL27 Heavy Duty Alligator Clip Set
Test Lead Set • TP74 Slim Reach Test Probe Set
• DMM test leads (red, black) (4 mm)
with safety shrouded, • TL224 SureGrip™ Silicone Test Lead Set
standard diameter banana • Large zippered soft case with moveable
plugs divider
• Heavy duty EPDM insulation
• Length 1.5 m
• CAT III 1000V, 10A rating.
UL listed
110
Industrial Test Leads,
Probes & Clips
TLK-225 SureGrip™ TP220 SureGrip™ Test Probe Set TP80 Electronic Test Probe Set
Master Accessory Kit • One pair (red, black) of Industrial test probes Recommended for use with TL222
• AC220 SureGrip™ Alligator • Sharp, 12 mm stainless steel tip and TL224
Clip Set provides reliable contact • One pair (red, black)
• AC280 SureGrip™ Hook Clip Set • Flexible finger barrier improves • IC insulated cap prevents
• AC283 SureGrip™ Pincer Clip Set grip shortening of IC legs for
• AC285 SureGrip™ Large Jaw • Recommended for use probing high density components or boards
Alligator Clip Set with TL222 and TL224 • CAT III 1000 V, 10 A rating. UL listed
• TP220 SureGrip™ Test Probe Set test leads
• TL224 SureGrip™ Silicone Test • CAT IV 600 V; CAT III 1000 V, 10 A rating.
Lead Set UL listed
• 6-Pocket Storage Pouch TLK291 Fused Test Probe Set
• One pair (red, black) fused test probes
• Designed to meet GS38 specs for
United Kingdom
TP74 Lantern Tip Test Probe Set • CAT III 1000V, 0.5A
TLK289 EUR Industrial Master
• One pair (red, black) • Fuse rating:
Test Lead Kit • Tips include banana-style spring 500 mA/1000 V/FF/50 kA
• C116, Soft Case contacts with nickel-plated brass
• AC220 Alligator Clip Set ends
• AC280 Hook Clip Set • CAT III 1000 V, 10 A rating.
• AC285 Large Jaw
Alligator Clip Set
UL listed New
• TP74 Lantern Tip
Test Probe Set FTP SureGrip™ Fused Test
• TL224 Test Lead Set TLK290 Test Probe Kit Probes
• TPAK Hanging Kit • Kit includes three flexible socket probes • Built-in fuses for added
• 80BK-A Temperature Thermocouple and a large alligator clip protection
• To be used on • 2 mm threaded probe tips include removable
three phase sockets. 4 mm lantern-style spring contacts
• Probes have flexible width • Removable GS38 insulted IC caps for probing
ACC-T5-KIT Accessory Kit for test points that fit securely in closely spaced leads
use with T5 4 to 8 mm sockets. • CAT III 1000 V, CAT IV 600 V, 10A
This kit completes the offering of a T5 • CAT III 1000 V, 8 A
with add-on probes and
carrying case.
• TP220 SureGrip™ Test Probe Set
• AC285 SureGrip™ Large Jaw Alligator TP1, TP2, TP4, TP38 New
Clip Set SlimReach Test Probe Sets
• C33 Soft Meter Case • One pair (red, black) of slender probes for
FTPL SureGrip™
closely spaced or recessed terminals
• TP1: Flat blade design to hold Fused Test Probes
securely in blade type wall with Leads
sockets • FTP Fused Test Probes with built-in fuses for
L215 SureGrip™ Kit • TP2: 2 mm diameter added protection
with Probe Light and tip for electronics work. • Includes TL224 Silicone Insulated Test Leads
Extender Also compatible with AC72. • CAT III 600 V, CAT IV 600 V, 10 A
• L200 Probe Light • TP4: 4 mm diameter tip
• TP280 20 cm Test Probe designed to fit into IEC wall
Extenders outlets
• TP220 SureGrip Test Probes • TP38: Insulated probe tip
• TL224 SureGrip Silicon Test Lead Set (designed to meet GS38 specs for
• Foldable soft pouch with six pockets and United Kingdom).
hook-and-loop • CAT IV 600 V, CAT III
1000 V, 10 A rating,
UL listed
111
All accessories have a one year warranty
Industrial Test Leads,
Probes & Clips
AC220 SureGrip™ Alligator Clip Set AC285 SureGrip™ AC72 Alligator Clip Set
• One pair (red, black) of small, insulated, Large Jaw Alligator Clip Set • Slide-on alligator clips (red,
nickel plated jaws • One pair (red, black) of large alligator black) for TL71/TL75
• Blunt tip grabs round screw heads up clips with nickel-plated steel jaws • Jaws provide 8 mm opening
to 9.5 mm • Multi-purpose tooth pattern grips • CAT IV 600 V, CAT III 1000 V,
• Recommended for use with anything from fine gauge wire to • 10 A rating. UL listed
TL222 and TL224 test leads a 20 mm bolt
• CAT IV 600 V, CAT III • Recommended for use with
1000 V, 10 A rating. TL222 and TL224 test leads
UL listed • CAT IV 600 V; CAT III 1000 V, 10 A rating.
UL listed Test Leads and Probes in one
AC280 SureGrip™ Hook Clip Set
• One pair (red, black) of nickel plated clips
• Profile narrows to 5.6 mm at The new standard for safer electrical
tip, hook opening 6.4 mm at front, measurements
AC87 Heavy Duty Bus Bar Clip Set
2 mm at base TL175 and TP175 TwistGuard™ test leads are
• One pair (red, black) of
• Recommended for use with the latest in the SureGrip™ technology from
flat, right angle design
TL222 and TL224 test leads Fluke that provides two safety features in
for connecting to bus
• CAT IV 600 V, CAT III 1000 V, one set of test leads. These new patented test
bars
3 A rating. UL listed leads provide two category rated tips
• Adjustable collar
provides 2 ranges of jaw (CAT III/IV) with a simple twist of the shroud.
openings up to 30 mm The lead wires on the TL175 are equipped with
• CAT III 600 V, 5 A rating. UL listed wear indication, that show when the leads
AC283 SureGrip™ Pincer Clip Set have excessive wear and that it is time to
• One pair (red, black) of nickel plated replace them. The TL175 and TP175 meet the
pincers open to 5 mm new NFPA 70E (IEC 61010-031) safety standard
• 11.4 cm flexible insulated shaft which is the standard for electrical safety in
• Recommended for use with the workplace.
TL222 and TL224 test AC89 Heavy Duty Insulation
leads Piercing Test Clip
• CAT IV 600 V, CAT III • Single probe pierces
1000 V, 1 A rating. 0.25 to 1.5 mm insulated wire New
UL listed • Small pin allows self-healing of the
insulation
• CAT IV 600V, CAT III 1000 V, 5 A rating.
UL listed
113
Current Clamps
Specifications AC models
i5s i50s i200 i200s i400 i400s
Continuous AC current range 0.01 A - 6 A 30 A cont. 50 A<10 sec 0.5 A - 200 A 0.1 - 24 A 5 A - 400 A 0.5 - 40 A
0.5 A - 200 A 5 A - 400 A
Output level(s) 400 mV/A 1/100 mV/A 1 mA/A 100 mV/A 1 mA /A 10 mV/A
10 mV/A 1 mV/A
1)
Basic Accuracy: % reading + floorspec
114
Current Clamps
1)
Basic Accuracy: % reading + floorspec
741B/743B/744
175/177/179
8845A/8846
430 Series
1577/1587
27II / 28II
83V/87V
187/189
287/289
123/124
8808A
77 IV
88V
43B
233
125
715
724
725
787
789
AC Models
i5s O O O
i200 4 O O O O O O O O O O O O O
i200s O O O O O O O O O O O O O O O O O O O O
i400 O O O O O O O O O O O O O
i410 Kit AC/DC Current Clamp i400s 2 2 2 2 2 2 2 2 2 2 2 O O O O O 2 2 2 2
(400A) with soft case i430 flex O
i1010 Kit AC/DC Current Clamp i800 4 O O O O O O O O O O O O O
(1000A) with soft case i1000s 2 2 2 2 2 2 2 2 2 2 2 O O O O 2 2 2 2
i2000 flex (new version) O O O O O O O O O O O 3 3 3 3 3 O O O
• Combination of current clamp with
i3000s O O O O O O O O O O O O O O O O O O O O
carrying case
i3000s flex O O O O O O O O O O O O O O O O O O O O
• Zipped soft case with moveable i6000s flex O O O O O O O O O O O O O O O O
divider AC/DC Models
• Soft case is large enough to hold a i30 O O O O O O O O O O O O O O
meter i30s O O O O O O O O O O O O O O O O
80i-110s 2 2 2 2 2 2 2 2 2 2 2 O O O O O O 2 2 2
i310s O O O O O O O O O O O O O O O O O O O O
i410 / i410 kit O O O O O O O O O O 3 3 3 O 1 1 1 O O O
i1010 / i1010 kit O O O O O O O O O O O 3 3 3 O 1 1 1 O O O
Other
90i-610s* 2 2 2 2 2 2 2 2 2 2 2 O O O 2 2 2 2
* For specifications of 90i-610s see page 113
1 For DC only
2 Requires PM 9081 (see page 76)
3 Requires PM 9082 (see page 76)
4 115, 117 only
115
All accessories have a one year warranty
Temperature Accessories
80PK-22 SureGrip™ Immersion Probe 80PK-1 and 80PJ-1 Bead Probe 80AK-A Thermocouple Adapter
• Type-K thermocouple for use in liquids • 80PK-1: Type-K thermocouple for • Adapts Type-K thermocouple
and gels general purpose applications mini-connector to dual banana
• Measurement range: • 80PJ-1 operates with J-type plug inputs
-40 to 1090°C thermometers • Measurement range and
• Probe length: 21.3 cm • Measurement range: accuracy: probe dependent
-40 to 260°C • Suitable for low voltage applications
• Probe length: (below 30 V AC, 60 V DC)
1 m lead wire
80PR-60 RTD Temperature Probe 80CK-M & 80CJ-M type K & J Male Thermocouple Plug Kits
• For simulaneously taking contact and Mini-Connectors 700TC1
non-contact temperature • Isothermal screw A kit of 10 mini-plug
measurements with terminal for K or J connectors
Fluke 66 or 68 wire Type J (black), one
• Measurement range: • Suitable for up to Type K (yellow), one
-40 to 260°C 20 guage Type T (blue), one
thermocouple wire Type E (purple), one
• Color coded to Type R/S (green), one
industry standards Type B or CU (white), one
(K-yellow, J-black) Type L (J-DIN) (blue), one
• Two per package Type U (T-DIN) (brown), one
Type C (red), one
Type N (orange), one
New 80PK-EXT, 80PJ-EXT and 700TC2
80PT-EXT Extension Wire Kits A kit of 7 mini-plug connectors
• Extending and repairing J, K ot T-type Type J (black), two
80PK-18 Pipe thermocouple wires Type K (yellow), two
Clamp Temperature Probe Kit • Kit includes 3 meters of thermocouple wire Type E (purple), one
• 80PK-8 Pipe Clamp Temperature Probe and 1 pair of male/female mini-connectors Type T (blue), one
• 80PK-10 Pipe Clamp Temperature Probe • Maximum continuous exposure temperature: Type R/S (green), one
• Soft Case 260ºC
• 80PK-EXT is compatible
with K-type thermometers,
80PJ-EXT is designed for
J-type thermometers and
PT-EXT for T-type
thermometers
8845A/8846A/8808A
741B/743B/744
51/52/53/54 II
120 Series
27II / 28II
175/177
287/289
566/568
705/707
66/68
1577
1587
77IV
83V
87V
88V
43B
179
233
561
714
715
724
725
787
789
Contact Probes
80PK-1 … 80PK-27 1 1 2 2 2 2 1 1 1 2 2 1 1 1 1 2 O O O 1 O 1 O O O 1 1
80PJ-1, 80PJ-9 O O O O O
80PT-25 1 O O O O O
DMM probes
80AK-A O3) O O O O O O O
80BK-A O3) O O O O O O O
80TK O O O O O O O O O O O O O
80T-150UA O O O O O O O O O O O O O O O O O
Miscellaneous
80CK-M 1 1 2 2 2 2 1 1 1 2 2 1 1 1 1 2 O O O 1 O 1 O O O 1 1
80CJ-M O O O O O
80PK-EXT4) 1 1 2 2 2 2 1 1 1 2 2 1 1 1 1 2 O O O 1 O 1 O O O 1 1
80PJ-EXT O O O O O
80PT-EXT O O O O O
700TC1, 700TC2 O O O O O
80PR-60 O
1) Requires 80TK
2) Requires 80AK
3) Fluke 116 only
4) Also requires 80CK-M
117
All accessories have a one year warranty
Cases and Holsters
Soft Cases
Zipped carrying cases protect your meter; most cases come with belt loops so your meter is
stored conveniently on your tool belt. C195
• Zipped carrying
case with storage
compartments
• Allows hand or
shoulder use
C789
• Large fabric carrying case
with 3 compartments,
C12A C23 C25 C33 C35 removable handle and
shoulder strap
190 Series/225C/215C
1503/1507/1577/1587
113/114/115/116/117
1735/1740 Series
712/714/715/717
43B/120 Series
741B/743B/744
51/52/53/54 II
83V/87V/88V
175/177/179
724/725/726
T100 Series
430 Series
570 Series
9040/9062
27II / 28II
63/66/68
287/289
321/322
353/355
566/568
705/707
77 IV
T50
233
922
971
561
718
787
789
T5
61
Soft Cases Size (HxWxD) mm
C12A 172 x 128 x 38 O O
C23 225 x 95 x 58 O O O O O O O
C25 218 x 128 x 64 O O O O O O O O O O O O O
C33 280 x 115 x 55 O O O O
C35 220 x 140 x 65 O O O O O O O O O O O O
C43 318 x 230 x 90 O O O O
C50 192 x 90 x 38 O O
C75 179 x 103 x 26 For multiple test leads and accessories
C90 205 x 90 x 72 O O O
C115 240 x 205 x 75 O O O O O O O O O O O
C116 240 x 230 x 65 O O O O O O O O O O O O O
C125 192 x 141 x 58 O O O O O O O O
C195 231 x 513 x 231 O O O
C280 230 x 185 x 65 O O O O O O O O O O O O O O O O
C345 240 x 360 x 200 For multiple test leads and accessories
C550 333 x 513 x 231 For multiple test leads and accessories
C570 240 x 160 x 61 O
C781 269 x 141 x 90 O O O O O O O O O
C789 308 x 256 x 77 O O O O O
Hard cases
C20 256 x 154 x 106
C100 397 x 346 x 122 O O O O O O
C101 305 x 360 x 105 O O O O O O O O O O O O O O O O O O O
C120 346 x 397 x 128 O
C190 410 x 474 x 135 O
C435 565 x 476 x 305 O O
C800 230 x 385 x 115 O O O O O O O
C1600 260 x 390 x 200 For multiple test leads and accessories
CXT80 28 x 32 x 13 O O O
CXT170 28 x 32 x 13 O O O O O O O
CXT280 28 x 32 x 13 O
Leather Cases
C510 287 x 179 x 106 O O O O O O O O O
C520A 256 x 154 x 106 O
Holsters
C10 154 x 77 x 45 O
H80M 190 x 95 x 43 O O O O
Other
H3 231 x 90 x 64 O O
H5 192 x 90 x 38 O
H6 302 x 178 x 57 O O O
118 Hanging Kit (see page 120)
ToolPak O O O O O O O O O O O O
Cases and Holsters
IR189USB
IR to USB interface cable
(included with FVF-SC2 and FVF-Basic)
• For customers who want to upgrade from
their existing RS232 cable
• Small adapter to connect the cable to the 189,
287, 289, 1653B or the 1550B is included.
• CD-Rom with drivers for use with older Fiber Optics
versions of FVF-SC1 included.
FOM Fiber Optic Meter
The Fluke Fiber Optic Meter (FOM) helps you
test and maintain fiber optic cables without
having to buy a whole new
meter. Plug the FOM
directly into any DMM with
Make extended logging easier a mV dc function and a
10 MΩ input impedance and
BP189 High Capacity Battery Enclosure quickly and accurately
(for Fluke 180 Series DMM) verify fiber optic cable system loss. Light
• Expand the battery life of your Fluke sources and patch cords sold separately.
187/189 up to 450 hours (over two weeks of
continuous use).
• Houses 4 ‘C’ cell batteries. FOS 850 & FOS 850/1300
• CAT III 1000 V, CAT IV 600 V
Fiber Optic Light Sources
Batteries and meter sold separately
A variety of light sources allow you to test
different cable lengths.
120
All accessories have a one year warranty
Other Accessories
L200 Probe Light SV225 Stray Voltage Adapter 80K-6 and 80K-40
• Attaches to any Fluke test probe Stray voltage can appear in A high voltage probe that
• Bright white LED electrical installations, due to allows a multimeter to
• 120 hours of battery life the capacity between wires. measure up to 6,000V or
This may result in erroneous 40,000V respectively.
readings on high impedance Intended for low energy applications only
meters.
L206 Deluxe LED Hat Light TL225 SureGrip™ Stray Voltage Adapter
(hard hat not included) Test Lead Kit
Attach it to a hard hat, Kit includes:
a baseball cap, or even a • SV225 Stray Voltage
panel door for all the light Eliminator
you need. • TL224 SureGrip™
• 3 super bright white LEDs Silicone Test Lead Set
– never burn out (right to straight)
• Special hard-hat attachment included • TP220 SureGrip™ Test
• 40-hour battery life Probe Set
• Includes three AAA batteries • C75 Accessory Case
121
All accessories have a one year warranty
Product Quick Find List
Model Page Model Page Model Page Model Page Model Page Model Page
Fluke 1AC I 32 Fluke 707 Ex 99,107 Fluke 8846A/SU 23 700PA4 Ex 102,107 EI-1623 40 PV350 113
Fluke 1AC II 32 Fluke 712 96 Fluke 9040 33 700PA5 102 EI-1625 40 RPM80 113
Fluke 1AC II 5PK 32 Fluke 714 96 Fluke 9062 33 700PA6 102 EI-162BN 40 RS200 76
Fluke 27II 21 Fluke 715 99 Fluke 9142-X 97 700PCK 102 ES-162P3 40 SCC120 73
Fluke 28II 21 Fluke 717 1G 98 Fluke 9143-X 97 700PD2 102 ES-162P4 40 SCC128 113
Fluke 43B 81 Fluke 717 100G 98 Fluke 9144-X 97 700PD3 102 ES165X (1653) 48 SCC190 75
Fluke 51 II 55 Fluke 717 1000G 98 Fluke CO-205 69 700PD4 102 EXTL100 48 SCC191 75
Fluke 52 II 55 Fluke 717 1500G 98 Fluke CO-220 69 700PD5 102 FLK-075-CLKT 59 SCC198 113
Fluke 53 II 55 Fluke 717 30G 98 Fluke Norma 4000 89 700PD6 102 FLK-100-CLKT 59 SM100 32
Fluke 54 II 55 Fluke 717 300G 98 Fluke Norma 5000 89 700PD7 102 FLK80P1 56 SM200 32
Fluke 61 52 Fluke 717 500G 98 Fluke RLD2 70 700PRV 102 FLK80P3 56 SM300 32
Fluke 62/322/1AC Kit 5, 52 Fluke 717 3000G 98 Fluke T5-600 31 700PTP 102 FLK-LENS-TELE1 61-63 SP1000 48
Fluke 62 52 Fluke 717 5000G 98 Fluke T5-600/62/1AC Kit 700PV3 102 FLK-LENS-WIDE 61-63 SP-Scan-15 48
Fluke 63 52 Fluke 718 Ex 98,107 5, 31 700PV4 102 FLK-Ti-SPB3 61-63 SV225 121
Fluke 66 52 Fluke 718 1G 98 Fluke T5-H5-1AC Kit 5, 31 700SW 93 FOM 120 SW90W 75
Fluke 68 52 Fluke 718 30G 98 Fluke T5-1000 31 700TC1 117 FOS 850 120 Ti-Car Charger 60-63
Fluke 771V 20 Fluke 718 100G 98 Fluke T50 30 700TC2 117 FOS 1300 120 Ti-SBC3 61-63
Fluke 83V 17 Fluke 718 300G 98 Fluke T100 30 884X-case 18 FS17XX 88 Ti-TRIPOD 60-63
Fluke 87V 17 Fluke 719 30G 98 Fluke T120 30 884X-512M 18 FTP SureGrip fused test Ti-Visor 60-63
Fluke 87V Ex 107 Fluke 719 100G 98 Fluke T140 30 975CK 67 probes 111 TL175 112
Fluke 87V/E2 Kit 4 Fluke 724 95 Fluke Ti9 60 975R 67 FTPL SureGrip fused test TL27 110
Fluke 87V/i410 4 Fluke 725 94 Fluke Ti10 60 975VP 67 probes with leads 111 TL28A 113
Fluke 88V/A 22 Fluke 725 Ex 94,107 Fluke Ti25 61 2373-LPRT 56 FVF- Basic 120 TL2X4W-PT-II 23-24
Fluke 113 19 Fluke 726 94 Fluke Ti32 61 2384P 56 FVF-SC1 120 TL2X4W-TWZ 23-24
Fluke 114 19 Fluke 741B 93 Fluke TiRx 62 2384T 56 FVF-SC2 120 TL40 109
Fluke 115 19 Fluke 743B 93 Fluke TiR 62 5616-12-P 56 FVF-SC4 120 TL71 110
Fluke 116 19 Fluke 744 93 Fluke TiR1 63 5615-9-P 56 FVF-SC5 120 TL75 110
Fluke 117 19 Fluke 771 100 Fluke TiR32 63 5610-9-P 56 FVF-UG 120 TL76 110
Fluke 117/322 Kit 4 Fluke 772 100 Fluke VR1710 79 AC72 112 GPS430 83 TL80A 109
Fluke 123 73 Fluke 773 100 80AK-A 116 AC87 112 H3 119 TL81A 109
Fluke 123/S 73 Fluke 787 101 80BK-A 116 AC89 112 H5 119 TL82 113
Fluke 124 73 Fluke 789 101 80CJ-M 117 AC220 112 H6 119 TL220 110
Fluke 124/S 73 Fluke 810 104 80CK-M 117 AC280 112 H80M 119 TL221 110
Fluke 125 73 Fluke 902 26 80i-110s 115 AC283 112 H900 110 TL222 110
Fluke 125/S 73 Fluke 922 68 80K-40 121 AC285 112 i1A/10A Clamp PQ3 88 TL223 110
Fluke 175 18 Fluke 922/Kit 68 80K-6 121 ACC-T5-Kit 111 i1A/10A Clamp PQ4 88 TL224 110
Fluke 177 18 Fluke 971 69 80PJ-1 116 AN5 51 i5A/50A Clamp PQ3 88 TL225 121
Fluke 179 18 Fluke 975 67 80PJ-9 116 APP1000/APP2000 48 i5A/50A Clamp PQ4 88 TL238 110
Fluke 179/TPAK kit 4 Fluke 975V 65 80PJ-EXT 117 AS200-G 76 i5s 114 TL910 109
Fluke 179/EDA2 Kit 4 Fluke 983 70 80PK-1 116 AS200-R 76 i20/200A Clamp PQ3 88 TL930 109
Fluke 179/MAG2 Kit 4 Fluke 1503 38 80PK-3A 116 BDST3 48 i20/200A Clamp PQ4 88 TL932 109
Fluke 179/61 Kit 4 Fluke 1507 38 80PK-8 116 BDST4 48 i30 115 TL935 109
Fluke 192C 75 Fluke 1523 56 80PK-9 116 BE9005 94 i30s 115 TL940 109
Fluke 192C/S 75 Fluke 1523-P1 56 80PK-10 116 BP120MH 76 i50s 114 TL950 109
Fluke 196C 75 Fluke 1524 56 80PK-11 116 BP189 120 i200 114 TL960 109
Fluke 196C/S 75 Fluke 1524-P1 56 80PK-18 117 BP190 76 i200s 114 TL970 109
Fluke 199C 75 Fluke 1550B 39 80PK-22 116 BP880 113 i310s 115 TLK-220 110
Fluke 199C/S 75 Fluke 1577 37 80PK-24 116 BP881 113 i400 114 TLK-225 111
Fluke 215C 75 Fluke 1587 37 80PK-25 116 BP980 109 i400s 114 TLK281 113
Fluke 215C/S 75 Fluke 1587/ET 5, 36 80PK-26 116 BP7235 102 i410 115 TLK282 113
Fluke 225C 75 Fluke 1587/MDT 5, 36 80PK-27 116 C10 118 i410 Kit 115 TLK287 109
Fluke 225C/S 75 Fluke 1587T 37 80PK-EXT 117 C12A 118 i430-flex-4pk 88 TLK289 111
Fluke 233 16 Fluke 1621 41 80PR-60 117 C20 119 i5sPQ3 88 TLK290 111
Fluke 287 15 Fluke 1623 40 80PT-EXT 117 C23 118 i800 114 TLK291 111
Fluke 289 15 Fluke 1623 Kit 40 80T-150UA 116 C25 118 i1000s 114 TP1 111
Fluke 287/FVF 5 Fluke 1625 40 80TK 116 C280 118 i1010 115 TP2 111
Fluke 289/FVF 5 Fluke 1625 Kit 40 90i -610s 113 C33 118 i1010 Kit 115 TP4 111
Fluke 321 27 Fluke 1630 42 700HTH 102 C345 118 i2000flex 114 TP38 111
Fluke 322 27 Fluke 1651B 44 700HTP 102 C35 118 i3000flex 114 TP40 113
Fluke 333 26 Fluke 1652B 44 700ILF 102 C43 118 i3000s 114 TP74 111
Fluke 334 26 Fluke 1653B 44 700LTP 102 C50 118 i6000s flex 114 TP80 111
Fluke 335 26 Fluke 1735 84 700P00 102 C75 118 IP-200-UK 59 TP81 113
Fluke 336 26 Fluke 1743 85 700P01 102 C90 118 IR 189USB 120 TP82 113
Fluke 337 26 Fluke 1743 Basic 85 700P01 Ex 102,107 C100 119 L200 121 TP84 113
Fluke 345 80 Fluke 1744 85 700P02 102 C101 119 L205 121 TP88 113
Fluke 353 28 Fluke 1744 Basic 85 700P03 102 C115 118 L206 121 TP220 111
Fluke 355 28 Fluke 1745 85 700P04 102 C116 118 L210 121 TP912 109
Fluke 360 29 Fluke 1750 86 700P05 102 C120 119 L215 111 TP920 109
Fluke 411D/62 Kit 5, 65 Fluke 1750/B 86 700P05 Ex 102,107 C125 118 LVD1 32 TPAK 120
Fluke 411D 65 Fluke 1760 87 700P06 102 C190 119 LVD2 32 TPS Clamp 50A / 5A 87
Fluke 416D 65 Fluke 1760 Basic 87 700P06 Ex 102 C195 118 MC6 121 TPS Clamp 200A / 20A 87
Fluke 421D 65 Fluke 1760TR 87 700P07 102 C435 119 MC50 121 TPS FLEX 18 87
Fluke 434 83 Fluke 1760TR Basic 87 700P08 102 C510 119 MTC1363 (UK) 48 TPS FLEX 24 87
Fluke 434 Basic 83 Fluke 2042 34 700P09 102 C520A 119 MTC77 (Europa) 48 TPS FLEX 36 87
Fluke 434 LOG 83 Fluke 2042T 34 700P09 Ex 102,107 C550 118 OC4USB 76 TPS Shunt 5 A 87
Fluke 435 83 Fluke 4180 97 700P22 102 C570 118 PAC91 76 TPS Shunt 20 MA 87
Fluke 435 Basic 83 Fluke 4181 97 700P23 102 C781 118 PASS560R 48 TPS Voltprobe 1 KV 87
Fluke 561 54 Fluke 4180-CASE 97 700P24 102 C789 118 PM8918/301 76 TPS Voltprobe 10 V 87
Fluke 566 53 Fluke 4180-DCAS 97 700P24 Ex 102,107 C800 119 PM9080 76 TPS Voltprobe 100 V 87
Fluke 568 53 Fluke 6200 46 700P27 102 C1600 119 PM9081 76 TPS Voltprobe 400 V 87
Fluke 572 51 Fluke 6500 46 700P27 Ex 102,107 CXT80 119 PM9082 76 TPS Voltprobe 600 V 87
Fluke 572CF 51 Fluke 8808A 24 700P29 102 CXT170 119 PM9090 76 VPS40 76
Fluke 574 51 Fluke 8808A/SU 24 700P29 Ex 102,107 CXT280 119 PM9091 76 VPS210-R/G series 76
Fluke 574CF 51 Fluke 8808A/TL 24 700P30 102 DMS 0100/INST 48 PM9092 76
Fluke 700 Ex 107 Fluke 8845A 23 700P31 102 DMS 0702/PAT 48 PM9093 76
Fluke 705 99 Fluke 8845A/SU 23 700PA3 102 DMS COMPL PROF 48 PM9094 76
122 Fluke 707 99 Fluke 8846A 23 700PA4 102 DP120 76 PT12 68
Fuse and Warranty Information
Product Warranty
Each Fluke product is warranted to be free from defects
in material and workmanship under normal use and
service, for the warranty period listed unless local law
requires a longer period. The warranty period is listed
in the ordering information section of the product
specification and begins on the date of shipment.
This warranty extends only to the original buyer or
end-user customer of a Fluke authorized reseller, and
does not apply to fuses, disposable batteries or to any
product which, in Fluke’s opinion, has been misused,
altered, neglected or damaged by accident or abnormal
conditions of operation or handling. Fluke warrants that
software will operate substantially in accordance with its
functional specifications for 90 days and that it has been
properly recorded on non-defective media. Fluke does
not warrant that software will be error free or operate
without interruption.
Lifetime Warranty
Each Fluke 20, 70, 80, 170, 180 and 280 Series DMM
purchased after October 1, 1996 will be free from defects
in material and workmanship for its lifetime. This
warranty does not cover fuses, disposable batteries and
damage from accident, neglect, contamination, misuse or
abnormal conditions of operation or handling, including
overvoltage failures caused by use outside the DMM’s
specified rating, or normal wear and tear of mechanical
components. This warranty covers the original purchaser
Fuse Replacement Information only and is not transferable. For ten years from the
date of purchase, this warranty also covers the LCD.
A V IR
Size Part nr Thereafter, for the lifetime of the DMM, Fluke will replace
in mm qty 1
the LCD for a fee based on then current component
63mA (slow) 250V 6.35x32 163030
125mA (slow) 250V 6.35x32 166488
acquisition costs.
250mA (slow) 250V 6.35x32 166306 To establish original ownership and prove date of
315 mA 1000V 10KA 6.35x32 2279339 purchase, please complete and return the registration
440mA 1000V 10kA 10.3x34.9 943121 card accompanying the product.
500mA 250V 1500A 5x20 838151
630mA 250V 1500A 5x20 740670
1A 600V 10kA 10.3x34.9 830828
1A 500V 50kA 6.35x 32 2530449 Service
1.25A 600V 6.35x32 2040349
3.15A 500V 6.35x32 2030852 Fluke will, at its discretion, repair at no charge, replace
11A 1000V 17kA Replaced by 11A, 1000V, 20kA fuse; 803293 or refund the purchase price of a defective product
11A 1000V 20kA 10.3x38.1 803293 purchased through a Fluke authorized sales outlet and at
15A 600V 100kA 10.3x38.1 892583 the applicable international price. Fluke reserves the right
20A 600V Replaced by 15A, 600V, 100kA fuse; part nr. 892583 to charge for importation costs of repair/replacement
parts if product purchased in one country is sent for
repair elsewhere.
See the back of your Fluke test tool or user manual for the fuses installed.
For manuals check the Fluke website in the product section. Send defective product with a description of the
For Fuse Replacement Guide check the Fluke website in the service section. problem to the nearest Fluke Authorized Service Center,
postage and insurance prepaid. Fluke will pay return
transportation for product repaired or replaced in-
warranty. Before making any non-warranty repair, Fluke
will estimate cost and obtain authorization, then invoice
you for repair and return transportation.
About Fluke
Networks
Fluke Networks provides innovative
solutions for the installation and
certification, testing, monitoring and
analysis of copper, fiber and wireless
networks used by enterprises and
telecommunications carriers.