Eng 01 A

Download as pdf or txt
Download as pdf or txt
You are on page 1of 125

Digital Multimeters

Clamp Meters
Electrical Testers
Insulation Testers
Earth Ground Testers
Installation Testers
Portable Appliance Testers
Digital Thermometers
Thermal Imagers
Distance Meters
Indoor Air Quality Tools
ScopeMeter® Test Tools

Test Tools Catalog 2010/2011


Power Quality Tools
Vibration Tester
Fluke. Keeping your world Field Calibrators
up and running.®
EX Test Tools
Fluke Corporation Accessories
P.O. Box 9090
Everett, WA USA 98206
Web: www.fluke.com
Fluke Europe B.V.
P.O. Box 1186
5602 BD Eindhoven
The Netherlands
Web: www.fluke.eu
For more information call:
In the U.S.A. (800) 443-5853
or Fax (425) 446-5116
In Europe/M-East/AFrica +31 (0)40 2 675 200)
or Fax +31 (0)40 2 675 222
In Canada (905) 890-7600
or Fax (905) 890-6866
From other countries +1 (425) 446-5500
or Fax +1 (425) 446-5116

Fluke (UK) Ltd.


52 Hurricane Way
Norwich
Norfolk
NR6 6 JB
United Kingdom

Tel.: (020) 7942 0700


Fax.: (020) 7942 0701
E-mail: [email protected]

Web: www.fluke.co.uk
© Copyright 2010, Fluke Corporation.

2010/2011
All rights reserved.
Printed in the Netherlands, 04/10
Data subject to alteration without notice.
Pub_ID: 11605-eng

Test Tools Catalog


Contents

Fluke web and electronic newsletter .................................................... 1 Laser Distance Meters ....................................................................... 64
New from Fluke........................................................................................ 2-3 421D/416D/411D Laser Distance Meters ........................................ 65
Fluke Combo Kits..................................................................................... 4-5

Indoor Air Quality Tools .................................................................... 66


Application/background articles ...................................................... 6 975 Air Meter...................................................................................... 67
Fluke After Sales Service ................................................................. 7 922 Airflow Meter .............................................................................. 68
Fluke where safety is built in .......................................................... 8-9 971 Temperature Humidity Meter................................................... 69
Fluke Industrial Portal ..................................................................... 10 983 Particle Counter .......................................................................... 70
Fluke Electrical Portal....................................................................... 11
Fluke Process Portal.......................................................................... 12

ScopeMeter® Test Tools...................................................................... 71


ScopeMeter Test Tools ...................................................................... 72
Digital Multimeters ............................................................................ 13 120 Series ScopeMeters .................................................................... 73
DMM Selection Guide ....................................................................... 14 190C Series, 215C/225C ScopeMeters ............................................ 74-75
280 Series Digital Multimeters ....................................................... 15 ScopeMeter Accessories ................................................................... 76
233 Remote Display Multimeter ...................................................... 16
80 Series V Digital Multimeters ....................................................... 17
170 Series Digital Multimeters ........................................................ 18
110 Series II Digital Multimeters ..................................................... 19 Power Quality Tools ........................................................................... 77
77 IV Digital Multimeter ................................................................... 20 Power Quality Selection Guide ........................................................ 78
27 II/28 II Rugged Industrial Multimeters ..................................... 21 1710 Plug-in Voltage Quality Recorder ......................................... 79
88V Automotive Meter...................................................................... 22 345 Power Quality Clamp Meter ...................................................... 80
8845A/8846A 6.5 Digit Precision Multimeters ............................... 23 43B Single-phase Power Quality Analyzer ..................................... 81
8808A 5.5 Digit Multimeter .............................................................. 24 430 Series Three-phase Power Quality Analyzers......................... 82-83
1735 Power Logger ............................................................................. 84
1740 Series Power Quality Loggers.................................................. 85
1750 Power Recorder ......................................................................... 86
Clamp Meters and Electrical Testers ................................................ 25 1760 Power Quality Recorder ........................................................... 87
330 Series/902 Clamp Meters........................................................... 26 Power Quality Current Clamp Accessories .................................... 88
320 Series Clamp Meters .................................................................. 27 Norma 4000/5000 Series ................................................................... 89-90
353/355 AC/DC Clamp Meters .......................................................... 28
360 Current Leakage Clamp Meter ................................................. 29
T100 Series Voltage/Continuity Testers .......................................... 30
T5/T5-H5-1AC Kit Electrical Testers................................................ 31 Field Calibrators ................................................................................. 91
1AC-I/1AC-II/LVD1/LVD2 Voltage Detectors ................................... 32 Field Calibrator Selection Guide...................................................... 92
9040/9062 Phase Rotation Indicators.............................................. 33 740 Series Documenting Process Calibrators ................................ 93
2042 Cable Locator ............................................................................ 34 726/725/725Ex Multifunction Process Calibrators ....................... 94
724 Temperature Calibrator ............................................................. 95
712/714 Temperature Calibrators .................................................... 96
9140X/418X Drywells/IR Calibrators ............................................... 97
Insulation Testers/Earth Ground Testers ......................................... 35 717/718/718Ex Pressure Calibrators ................................................ 98
Insulation Tester Selection Guide ................................................... 36 706/707/707Ex/715 Loop Calibrators ............................................... 99
1577/1587 Insulation Multimeters .................................................. 37 771/772/773 mA Clamp Meters....................................................... 100
1503/1507 Insulation Testers ........................................................... 38 787/789 ProcessMeters...................................................................... 101
1550B MegOhmMeter........................................................................ 39 Process Tools Accessories................................................................. 102
1620 Series Earth Ground Testers ................................................... 40
1621 Earth Ground Tester ................................................................. 41
1630 Ground Loop Tester .................................................................. 42
Vibration Tester.................................................................................. 103
810 Vibration Tester .......................................................................... 104

Installation Testers/Portable Appliance Testers .............................. 43


1650B Series Multifunction Installation Testers ........................... 44-45
6000 Series Portable Appliance Testers .......................................... 46-47 ATEX Certified Test Tools .................................................................. 105
1650B/6000 Series Accessories ........................................................ 48 A brief look at ATEX .......................................................................... 106
Fluke intrinsically safe tools............................................................ 107

Digital Thermometers ....................................................................... 49


Infrared Thermometer Selection Guide ......................................... 50 General Accessories........................................................................... 108
570 Series Precision Infrared Thermometers ................................ 51 Electronic Test Leads, Probes & Clips ............................................. 109
60 Series Infrared Thermometers ................................................... 52 Industrial Test Leads, Probes & Clips.............................................. 110-111-112
566/568 Multipurpose Thermometers ............................................ 53 Automotive Accessories ................................................................... 113
561 Multipurpose Thermometer ..................................................... 54 Current Clamps ................................................................................. 114-115
50 Series Thermometers .................................................................. 55 Temperature Accessories ................................................................. 116-117
1523/1524 Reference Thermometers .............................................. 56 Cases and Holsters............................................................................ 118-119
Software and Other Accessories ..................................................... 120
Other Accessories.............................................................................. 121
Product Quick Find List .................................................................... 122
Thermal Imagers ............................................................................... 57 Fuse and Warranty Information...................................................... 123
Ti Series Thermal Imagers ............................................................... 58
Hawk IR CRange IRWIndows ........................................................... 59
Ti19/Ti10 Electrical Thermal Imagers ............................................. 60
Ti25/Ti32 Industrial Thermal Imagers ............................................ 61 Fluke. Keeping your world
TiRx/TiR Thermal Imagers for Building Inspection ...................... 62
TiR1TiR32 Thermal Imagers for Building Diagnostics.................. 63 up and running

See page 122 for a Product Quick Find List per model number
New from Fluke

Fluke 233 Remote Display Multimeter


The Fluke 233 allows you to be in two places at once. The removable
display solves the problem of holding both the meter and the test leads
to make a measurement.

See page 16.

Fluke 27 II/28 II Rugged Industrial Multimeters


The Fluke 27 II and 28 II define a new standard for operating in harsh
conditions with the features are accuracy to troubleshoot most electrical
problems. Both multimeters have IP67 rating.

See page 21.

Fluke RLD2 Leak Detector Flashlight


The Fluke RLD2 UV Flashlight uncovers refrigerant leaks instantly.
Use the UV light to find the leakage area, then, use the laser pointer to
pinpoint the exact leak location.

See page 70.

Fluke Ti32/Ti9 Industrial Thermal Imagers


The Ti32 with its 320x240 sensor is the tool built for top professionals
who need to see the smallest details. The affordable Fluke Ti9 puts the
power of thermal imaging into the hands of electricians and technicians
who are most familiar with the installations.

See page 60 and 61.

Fluke TiR32/TiRx Thermal Imagers for Buildings


The Fluke TiR32 with its 320x 240 sensor features the highest level of
thermal sensitivity to identify even small temperature differences. This
makes it the ideal tool for building diagnostics. The Fluke TiRx is the
perfect affordable thermal imager for building inspection.

See page 62 and 63.

Hawk-IR CRange IRWindows


These arc-resistant, outdoor certified, infrared windows allow thermal,
ultraviolet, visual and fusion technologies to be used without exposing
personnel to live equipment.

See page 59.

2
New from Fluke

Fluke 1750 Power Recorder


With its exclusive threshold-free measurement system, the Fluke 1750
Power Recorder captures every measurement, every event, on every cycle,
all the time. Outstanding accuracy and resolution provide complete
visibility into your installation or distribution system.

See page 86.

Fluke 421D Laser Distance Meter


The Fluke 421D brings greater distance and advanced features to the
Fluke laser distance meter family. It can measure a distance up to 100
m with 1/16 in accuracy and has a 45º tilt sensor for taking indirect
measurements in hard to reach areas.

See page 65.

Fluke 772/773 Milliamp Process Clamp Meters


The Fluke 772 and 773 measure 4 to 20 mA signals without “breaking the
loop”, just like the popular Fluke 771. Now technicians in process plants,
industrial plants, commercial buildings and automotive repair shops can
choose exactly the range of capabilities they need, at a price that makes
sense.

See page 100.

Fluke 810 Vibration Tester


The Fluke 810 Vibration Tester is the most advanced troubleshooting
tool for mechanical maintenance teams who need an answer now. The
unique diagnostic technology helps you quickly identify and prioritize
mechanical problems, putting the expertise of a vibration analyst in your
hands.

See page 104.

FTPL Fused Test Probe Set


The FTPL are test probes with built-in fuses for additional measurement
protection. And, if the probe fuse does blow, these probes will still
allow the meter to indicate live voltage helping to prevent a possible
misreading of no voltage present.

See page 111.

80PK-18 Pipe Clamp Temperature Probe Kit


The 80PK-18 combines the standard 80PK-8 pipe clamp with the new
larger sized 80PK-10 pipe clamp, to give you a full range of measurement
sizes. The 80PK-10 can measure on pipe diameters van 32 mm to 64 mm.

See page 116 and 117.

3
Fluke Combo Kits

Buy a Combo Kit and save


Fluke 179/MAG2 Kit
Fluke 117/322 Kit Industrial Combo Kit
Electrician’s Combo Kit • Fluke 179 True RMS
• Fluke 117 True RMS Multimeter
Multimeter • TL224 SureGrip™ Silicone Test
• Fluke 322 Clamp Meter Lead Set
• TL75 Hard Point Test Lead Set • AC220 SureGrip™ Alligator
• TPAK Magnetic Hanger Clip Set
• C115 Deluxe carrying case • TP4 Slim Reach Test Probe Set
with shoulder strap (4 mm)
• TPAK Magnetic Hanger
• 80BK-A Integrated DMM
Temperature Probe
• C35 Soft Meter Case
• + Maglite flashlight

Fluke 179/TPAK Fluke 179/EDA2 Kit


179/ToolPak Combo Kit Electronics Combo Kit
• Fluke 179 True RMS • Fluke 179 True RMS
Multimeter Multimeter
• TPAK ToolPak Meter Hanging • TL224 SureGrip™ Silicone Test
Kit Lead Set
• TL910 Electronic Test Probe
Set
• AC280 SureGrip™ Hook Clip
Set
• TPAK Magnetic Hanger
• 80BK-A Integrated DMM
Temperature Probe
• C35 Soft Meter Case

Fluke 179/61 Kit Fluke 87V/E2


Multimeter and Infrared Industrial Electrician
Thermometer Combo Kit Combo Kit
• Fluke 179 True RMS • Fluke 87V True RMS
Multimeter Multimeter
• Fluke 61 Infrared • TL224 SureGrip™ Silicone Test
Thermometer Lead Set
• C550 Hard Meter and • TP38 Slim Reach Test Probe
Accessory Case Set (insulated)
• AC220 SureGrip™ Alligator
Clip Set
• TPAK Magnetic Hanger
• 80BK-A Integrated DMM
Temperature Probe
• C35 Soft Meter Case

Fluke 87V/i410
Combo Kit for Industrial
Applications
Ordering Information • 87V Industrial Multimeter
• TL75 Test Leads
Fluke 117/322 Kit • AC72 Alligator Clips
Fluke 179/TPAK • i410 400A AC/DC Current
Fluke 179/61 Kit Clamp
Fluke 179/MAG2 Kit • 80BK-A Temperature Probe
Fluke 179/EDA2 Kit • C115 Soft Carrying Case
Fluke 87V/E2
Fluke 87V/i410 (Not available in all countries)

4
Fluke Combo Kits

Buy a Combo Kit and save

Fluke 287/FVF FlukeView Fluke 1587/MDT


Forms Combo Kit Advanced Motor & Drive
• Fluke 287 True RMS Electronic Troubleshooting Kit
Logging Multimeter with • Fluke 1587 Insulation
TrendCapture Multimeter
• FVF-SC2 FlukeView Forms • Fluke 9040 Phase Rotation
Software and cable Indicator
• 80BK-A Thermocouple Probe • I400 Current Clamp
• CAT III 1000 V 10 A Modular
Fluke 1587/MDT
Test Leads (red, black)
• CAT II 300 V 5 A Alligator Clips
(red, black)
• C280 Soft Case for meter
protection and accessory
storage
Fluke T5-H5-1AC Kit
• Fluke T5-1000 Electrical Tester
Fluke 289/FVF Industrial • H5 Holster
Logging Multimeter and • 1AC-II Volt Alert
Software Combo Kit
• Fluke 289 True-RMS
Multimeter
• FVF-SC2 FlukeView Forms
Software and cable
• TL71 Silicon Test Lead Set
• AC72 Alligator Clips
• 80BK-A Integrated DMM
Temperature Probe
• TPAK Magnetic Meter Hanger Fluke T5-600/62/IAC Kit
for hands-free operation • Fluke T5-600 Electrical Tester
• C280 Soft Case for meter • Fluke 62 Mini IR Thermometer
protection and accessory • Fluke 1AC-II Volt Alert
storage • C115 Soft Meter Case

Fluke 1587/ET Advanced


Electrical Troubleshooting Kit
• Fluke 1587 Insulation Multimeter
• Fluke 62 Mini Infrared
Thermometer
• I400 Current Clamp
Fluke 62/322/1AC Kit
• Fluke 62 Mini IR Thermometer
• Fluke 322 Clamp Meter
• Fluke 1AC-II Volt Alert

Ordering Information

Fluke 287/FVF
Fluke 289/FVF Fluke 411D/62 Kit
Fluke 1587/ET • Fluke 411D Laser Distance
Fluke 1587/MDT Meter
Fluke T5-H5-1AC Kit • Fluke 62 Mini IR Thermometer
Fluke T5-600/62/IAC Kit • Soft case for each model
Fluke 62/322/1AC Kit
Fluke 411D/62 Kit

5
Application/
background articles

As part of our commitment to supporting you in your work we do


more than just design and manufacture rugged and versatile test tools:
we also provide application notes which all can be downloaded from
our web site. Furthermore check our three new dedicated web portals:
Industrial Portal, Electrical Portal and Process Portal. In addition to
inspection tips and helpful application information, the portals also
offer advice on picking the right tool for the job.

6
Let Fluke After Sales Service
help you further

Did you know that the Fluke after sales What other value added services do
service team can offer you much more we offer?
than just repairing and calibrating your • Gold Support for Fluke Networks
instrument when it is needed? Across • Gold CarePlans for calibration products
our whole Fluke European service • A full range of maintenance contracts
• Extended warranty programs
organization we have a vast range of
• Instrument upgrades
capabilities, which can be utilized via So why should you use Fluke service? • Option retrofits
your local service centre. Behind the • Original manufacturers’ parts used • Asset management
scenes Fluke draws on the expertise of • All instruments reviewed for latest updates • Calibration reminders
over 150 service staff that are focused • Repair warranty that covers whole unit
on offering only the best and most • In depth product knowledge What services do we offer you?
• Accredited calibrations available • 5 day repairs on all current products
comprehensive after sales service. • Traceable calibrations available on all • 5 days or less on all calibrations (excl.
products repairs)
• Full check of unit during verification cycle • 3 days for all Gold CarePlan calibrations
• Full safety test on mains powered units • 1-2 days on all Networks Gold calibration
• Pick up services where available
What other instruments can we help
you with?
We also offer a range of calibrations and
repairs on other manufacturer’s equipment
upon request. Manufacturers such as:
• Tektronix
• Agilent
• Bruel & Kjaer
• Philips
• Megger
• Seaward
• Kewtech
• Lecroy
• Hioki
• Yokogawa
• Druck
• Iwatzu
• plus many more ...
Fluke service centres handle a wide range
of equipment.
As part of Fluke’s continuing focus on improving
our service to our customer we now offer a
comprehensive range of repairs and calibrations
on a vast range of equipment. On-Line booking in system
Fluke manufactures equipments such as: Why not use our On-Line booking in system
where you can book your unit in, get pricing
and receive a RMA number for a smooth
Fluke Brands Instrument Types return.
Fluke Digital Multimeters
www.fluke.com/servicerma
Hart Scientific Electrical Standards
Fluke Networks Biomedical Equipment
Fluke Biomedical Data Loggers
Raytek Thermal Imagers
Reliable Power Meters Thermometers
Robin Pressure
LEM Instruments Function Generators
BEHA Oscilloscopes
Norma Installation Testers
Wavetek/Datron PAT Testers
Metron Clamp Meters
DHI Power Analyzers
Comark EX meters Contact Information
Plus many more
Eindhoven Norwich Cologne
Telephone +31 (0)40 267 5300 +44 (0)1603 256620 +49 (0)69 2222 20210
Telefax +31 (0)40 267 5321 +44 (0)1603 256688 +49 (0)69 2222 20211
Email [email protected] [email protected] [email protected]
Address Science Park 5108 52 Hurricane Way Heinrich-Pesch-Str. 9-11
Eindhoven Norwich 50739 Köln
5692 EC Son Norfolk Germany
Netherlands NR6 6JB
United Kingdom

7
Fluke: Where safety is built in

As distribution systems and loads Who Develops Safety Standards? of the 12 Ω test source for CAT II. The CAT III
become more complex, the possibilities The IEC (International Electrotechnical 600 V meter clearly offers superior transient
of transient overvoltages increase. Commission) develops international general protection compared to the CAT II 1000 V
standards for safety of electrical equipment meter, even though its so-called “voltage
Motors, capacitors and power conversion
for measurement, control and laboratory rating” could be perceived as being lower. See
equipment such as variable speed drives Table 2.
use. IEC61010-1 is used as the basis for the
can be prime generators of spikes. following national standards:
Lightning strikes on outdoor transmission • US ANSI/ISA-S82.01-94 Independent testing is the key to safety
lines also cause extremely hazardous • Canada CAN C22.2 No.1010.1-92 compliance
high-energy transients. If you’re taking • Europe EN61010-1:2001 How can you tell if you’re getting a genuine
measurements on electrical systems, CAT III or CAT II meter? Unfortunately it’s
these transients are “invisible” and Overvoltage Installation Categories not always that easy. It is possible for a
largely unavoidable hazards. They occur IEC61010-1 specifies categories of manufacturer to self-certify that its meter
regularly on low-voltage power circuits, overvoltage based on the distance the piece is CAT II or CAT III without any independent
of equipment is from the power source verification. The IEC (International
and can reach peak values in the many
(see Fig. 1 and Table 1) and the natural Electrotechnical Commission) develops and
thousands of volts. To protect you against damping of transient energy that occurs proposes standards, but it is not responsible
transients, safety must be built into the in an electrical distribution system. Higher for enforcing the standards. Look for the
test equipment. categories are closer to the power source and symbol and listing number of an independent
require more protection. testing lab such as UL, CSA, VDE, TÜV or other
Within each installation category there are recognized approval agency.
voltage classifications. It is the combination of These symbols can only be used if the product
installation category and voltage classification successfully completed testing to the agency’s
which determines the maximum transient standard, which is based on national and
withstand capability of the instrument.

IEC 61010 test procedures take into account


three main criteria: steady-state voltage,
peak impulse transient voltage and source international standards. UL 3111, for example,
impedance. These three criteria together will is based on EN61010-1. In an imperfect world,
tell you a multimeter’s true voltage withstand this is the closest you can come to ensuring
value. that the meter you choose was actually tested
for safety.
Within a category, a higher working voltage”
(steadystate voltage) is associated with a
higher transient, as would be expected. For
example, a CAT III 600 V meter is tested
with 6000 V transients while a CAT III 1000 V
meter is tested with 8000 V transients.
So far, so good. What is not as obvious is the
difference between the 6000 V transient for
Figure 1. Understanding categories: location CAT III 600 V and the 6000 V transient for
CAT II 1000 V. They are not the same. This is
where the source impedance comes in. Ohm’s
Law (Amps = Volts/Ohms) tells us that the 2 Ω
test source for CAT III has six times the current

Table 1
Overvoltage category In brief Examples
CAT IV Three-phase at utility connection, • Refers to the “origin of installation”; i.e., where low-voltage connection is made to utility power.
any outdoor conductors • Electricity meters, primary overcurrent protection equipment.
• Outside and service entrance, service drop from pole to building, run between meter and panel.
• Overhead line to d etached building, underground line to well pump.
CAT III Three-phase distribution, including • Equipment in fixed installations, such as switchgear and polyphase motors.
single-phase commercial lighting • Bus and feeder in industrial plants.
• Feeders and short branch circuits, distribution panel devices.
• Lighting systems in larger buildings.
• Appliance outlets with short connections to service entrance.
CAT II Single-phase receptable • Appliance, portable tools, and other household and similar loads.
connected loads • Outlet and long branch circuits.
• Outlets at more than 10 meters (30 feet) from CAT III source.
• Outlets at more than 20 meters (60 feet) from CAT IV source.
CAT I Electronic • Protected electronic equipment.
• Equipment connected to (source) circuits in which measures are taken to limit transient overvoltages
to an appropriately low level.
• Any high-voltage, low-energy source derived from a high-winding resistance transformer, such as the
high-voltage section of a copier.

Overvoltage installation categories. IEC 61010-1 applies to low-voltage (< 1000V) test equipment
8
Fluke: Where safety is built in

Safety is everyone’s responsibility but Select the right test tool: Inspect and test your test tool:
ultimately it is in your hands. • Choose a test tool rated to the highest • Check for a broken case, worn test leads or
No tool by itself can guarantee your safety category and voltage for which it could a faded display.
when working with electricity. It’s the possibly be used (most often 600 or 1000 • Make sure the batteries still deliver
volt CAT III and/or 600 volt CAT IV). sufficient power to get reliable readings.
combination of the right tools and safe
• Look for the category and voltage marking Many test tools have a low battery indicator
work practices that gives you maximum near the recessed input connectors of your on the display.
protection. Here are a few tips to help you test tool and a “double insulated” symbol • Check the test leads resistance for internal
in your work: on the back. breaks while moving the leads around
• Verify your test tool has been tested and (good leads measure 0.1-0.3 Ohm).
Make sure you always comply with (local) certified by two or more independent • Use the meter’s own test capability to
regulations. testing laboratories, such as UL in the ensure that the fuses are in place and
United States and VDE or TüV in Europe by working right (see manual for details).
looking for the symbols of these agencies
Work on de-energized circuits whenever
on (the back of) your test tool. Apply the appropriate working
possible. • Make sure that the test tool is made of
Use proper lock-out/tag-out procedures. If these practices when measuring on live
a high-quality, durable non-conductive circuits:
procedures are not in place or enforced, assume material.
that the circuit is live. • Hook on the ground clip first, then make
• Check the manual to verify that the contact with the hot lead. Remove the hot
ohms, continuity and capacitance circuits lead first, the ground lead last.
Use protective gear when working on live are protected to the same level as the • Use the three-point test method, especially
circuits: voltage test circuit, to reduce hazards when checking to see if a circuit is dead.
• Use insulated tools when the test tool is used incorrectly in First test a known live circuit. Second,
• Wear safety glasses or a face shield ohms, continuity or capacitance mode (if test the target circuit. Third, test the live
• Wear insulated gloves, remove watches or applicable). circuit again. This verifies that your test
jewelry • Verify that the test tool has internal tool worked properly before and after the
• Stand on an insulated mat protection to prevent instrument damage measurement.
• Wear flame resistant clothing, not ordinary when voltage is incorrectly applied to • Hang or rest the test tool if possible.
work clothes an amperage measurement function (if Try to avoid holding it in your hands, to
applicable). minimize personal exposure to the effects
• Make sure that the amperage and of transients.
voltage of your test tool’s fuses meets • Use the old electrician’s trick of keeping
specifications. Fuse voltage must be as high one hand in your pocket. This lessens the
or higher than the test tool’s voltage rating. change of a closed circuit across your chest
• Be sure to use test leads that have: and through your heart.
- Shrouded connectors
- Finger guards and a non-slip surface
- Category ratings that equal or exceed
those of the test tool
- Double insulation (look for the symbol)
- A minimum of exposed metal on the
probe tips

For more information or to see the Electrical Safety video go to:


United Kingdom: www.fluke.co.uk/safety
Ireland: www.fluke.ie/safety
E-Europe/Middle-East/Africa: www.fluke.nl/safety_ex

Use protective equipment such as safety glasses and


insulated gloves Table 2
Overvoltage Working Voltage Peak Impulse
Test Source
Installation (DC or AC RMS Transient
(Ω = V/A)
Category to ground) (20 repetitions)
CAT I 600 V 2500 V 30 Ohm source
CAT I 1000 V 4000 V 30 Ohm source
CAT II 600 V 4000 V 12 Ohm source
CAT II 1000 V 6000 V 12 Ohm source
CAT III 600 V 6000 V 2 Ohm source
CAT III 1000 V 8000 V 2 Ohm source
CAT IV 600 V 8000 V 2 Ohm source

Use meters with these markings: Transient test values for overvoltage installation categories.
1000 V CAT III or 600 V CAT IV (50 V/150 V/300 V values not included)
9
Fluke Industrial Web Portal
Reduce downtime and unnecessary repairs

Motors & drives Automation systems

Power distribution Plant infrastructure

Heavy loads Worn Incorrect Wrong Unbalanced Cable/ Equipment Lack of


bearings motor motor/drive harmonics connection end-of-life maintenance
connections damage

Incorrect motor
Overloading and mechanical strain could be signs that the motor is underperforming or inadequate for the job.
Use an infrared thermometer to quickly locate hot spots, and see areas of excessive heat with a thermal imager to determine severity. A digital
multimeter will determine if the current draw is too high, which is also a sign that the motor is inadequate for the demands placed on it. With
a clamp meter measure the inrush current and high load currents.

Fluke 568 Thermometer Fluke Ti32 Thermal Imager


• High accuracy • 320 x 240 sensor for clear, crisp images
• Easy interface • IR-Fusion® blended thermal images
• Infrared and contact bead probe • Rugged, withstands 2 m drop
• Trending and reporting via PC • High resolution and thermal sensitivity
• Full analysis and reporting software
included

Fluke 87V True RMS Multimeter Fluke 337 True RMS Clamp Meter
• Accurate frequency and voltage • In-rush current function for motor
measurements on motor drives and starting, inductive lighting, etc.
electrically noisy environments. • AC/DC voltage and frequency
• Built-in thermometer measurements
• Jaw opening 42 mm

www.fluke.eu/industrial
Visit the full portal with practical information about troubleshooting potential problems throughout the plant.
See how to find the right test tool for the job.

10
Fluke Electrical Web Portal
A solution for every application

Electrical installation testing Power consumption Service/repair

Electrical Installation Testing


Setting up new installations, extending an existing installation or trouble shooting around safety is always crucial. To avoid any safety issues,
with a multifunctional installation tester all safety measurement are combined in one single tester, testing a RCD or measuring the loop etc.

A voltage tester is the every day tester when working in an electrical installation, quickly check voltage or continuity. The T5 with its
OpenJawTM technology allows current measurement on tight spaces such as for example on a distribution board.

Fluke 1650B Series Fluke T5-1000 Electrical Tester


Installation Testers • Voltage and continuity measurement
• Insulation test, continuity test, high • OpenJaw™ technology for current
current loop test, RCD test, earth ground checks up to 100 A
test
• Slim probe with test button

Fluke T120 Voltage and


Continuity Tester
• Voltage, continuity and resistance
measurements
• Three-phase rotation detection system

www.fluke.eu/electrical
Visit the full portal with practical information for the electrical installer.
See how to find the right test tool for the job.

11
Fluke Process Web Portal
Identifying potential problems

Testing in Ex. Classified areas Automation Systems

Maintenance and calibration Instrument commissioning


of process instruments and service

Measuring, Temperature Pressure Switch testing Custody transfer Troubleshooting


troubleshooting calibrations calibrations process signals
4-20mA loop
signals

Measuring troubleshooting 4-20 mA loop signals


Keeping manufacturing and processing plants running at maximum efficiency 24-hours a day requires regular inspection and troubleshooting
of vital systems and equipment. 4-20mA control loops are the most common control signals used in process industries today. Troubleshooting
the mA loop instruments, connections, and cables are an essential part of locating and reparing process control.

Fluke 707Ex Loop Calibrator Fluke 725Ex Multifunction


• Simultaneous mA and % Process Calibator
• mA accuracy of 0.02% • Measure, source and view process
• Measure, source and simulate mA signals simultaneously
• Measure volts, mA, RTDs,
thermocouples, frequency, and
resistance to test sensors and
transmitters.

Fluke 87VEx True RMS Multimeter


• Accurate frequency and voltage
measurements on motor drives and
electrically noisy environments.
• Built-in thermometer

www.fluke.eu/process
Visit the full portal with practical information about troubleshooting potential problems in the process control
environment. See how to find the right test tool for the job.

12
Digital Multimeters

Safety, quality and performance: three words that sum up the benefits of
our extensive range of digital multimeters. Designed to help you do your
job faster, more efficiently and with greater accuracy, there is a model for
every budget and application. Choose from handheld troubleshooters to
ultra smart instruments packed with features, including the ability to log
and graph data, as well as high-precision bench units.

13
14
Remote Industrial maintenance Field Heavy duty General Auto-
Highest accuracy High-end Industrial Electrical HVAC/R Basic Electrical Loop calibration Insulation test
display and field service Service (IP67) Purpose motive

Basic features 289 287 233 87V 83V 179 177 175 117 116 115 114 113 27II 28II 77IV 88V 789 787 1587 1577
Counts 50000 50000 6000 20000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 20000 6000 20000 4000 4000 6000 6000
True RMS readings AC+DC AC+DC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC
Basic DC accuracy 0.025% 0.025% 0.25% 0.05% 0.1% 0.09% 0.09% 0.15% 0.5% 0.5% 0.5% 0.5% 2.0% 0.1% 0.05% 0.3% 0.1% 0.1% 0.1% 0.09% 0.2%
Wide bandwidth 100 kHz 100 kHz 20 kHz 5 kHz 20 kHz 50 kHz
Auto/manual ranging O/O O/O O/O O/O O/O O/O O/O O/O O/O O/O O/O O/O O/O O/O O/O O/O O/O O/O O/O O/O O/O
Measurements
Voltage AC/DC 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 600 V 600 V 600 V 600 V 600 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V
Current AC/DC 10 A 10 A 10 A 10 A 10 A 10 A 10 A 10 A 10 A 200 μA 10 A 10 A 10 A 10 A 10 A 1A 1A 400 mA 400 mA
Resistance 500 MΩ 500 MΩ 40 MΩ 50 MΩ 50 MΩ 50 MΩ 50 MΩ 50 MΩ 40 MΩ 40 MΩ 40 MΩ 40 MΩ 60 kΩ 50 MΩ 50 MΩ 50 MΩ 50 MΩ 40 MΩ 40 MΩ 50 MΩ 50 MΩ
Frequency 1 MHz 1 MHz 50 kHz 200 kHz 200 kHz 100 kHz 100 kHz 100 kHz 50 kHz 50 kHz 50 kHz 200 kHz 200 kHz 100 kHz 200 kHz 20 kHz 20 kHz 100 kHz
Capacitance 100 mF 100 mF 10 mF 10 mF 10 mF 10 mF 10 mF 10 mF 10 mF 10 mF 10 mF 10 mF 10 mF 10 mF 10 mF 10 mF 10 mF
Temperature +1350ºC +1350ºC +400ºC +1090ºC +400ºC +400ºC +1090ºC +1090ºC +500ºC
dB 60 dB 60 dB
Conductance 50 nS 50 nS 60 nS 60 nS 60 nS 60 nS 60 nS
Duty cycle/pulse width O/O O/O O/- O/- O/O O/O O/O
Continuity with beeper/Diode test O/O O/O O/O O/O O/O O/O O/O O/O O/O O/O O/O O/- O/O O/O O/O O/O O/O O/O O/O O/O O/-
4-20mA loop current as % readout O O
Motor drive measurement O O O O
RPM/Dwell O/-
VoltAlertTM, Non-contact voltage detection O
LoZ: low input impedance O O O O
VCHEKTM LoZ O
Microamps O O O O O
Insulation test O O
Number of insulation test ranges 5 2
Display
Dual display O O O O
Analog bargraph O O O O O O O O O O O O O O O O O
Backlight O O O O O O O O O O O O O O O O O O O O
Remote display O
Data storage and exchange
Min-Max recording/with time stamp O/O O/O O O/- O/- O/- O/- O/- O/- O/- O/- O/- O/- O/- O/- O/- O/- O/- O/- O/-
Fast Min-Max 250 μs 250 μs 250 μs 250 μs 250 μs
Display Hold/Auto (Touch) Hold O/O O/O O O/O O/O O/O O/O O/O O/- O/- O/- O/- O/- O/O O/O -/O O/O -/O -/O O/O
Relative O O O O O O O O O
Stand alone logging/TrendCapture O/O O/O
USB interface/RS232 interface O/O O/O O/O
Readings memories 10000 10000
Other features
Source 4-20mA loop current/24V loop supply O/O O/-
Automatic selection, AC/DC volts O O O
Real time clock O O
Smoothing O O O O
DMM Selection guide

Integrated holster O O O O O O O O
Removable holster O O O O O O O O O O O O O
Closed case calibration O O O O O O O O O O O O O O O O O O O O
Seperate battry/fuse access O/O O/O O/O O/- O/- O/O O/O O/O O/- O/- O/- O/- O/- O/O O/O O/- O/O O/- O/O O/O
Completely sealed/watertight O O
Automatic power off O O O O O O O O O O O O O O O O O O O O
Low battery indication O O O O O O O O O O O O O O O O O O O O
Warranty and safety
Lifetime warranty/warranty (years) O O 3 O O O O O 3 3 3 3 3 O O O O 3 3 3 3
Input alert O O O O O O O
Dangerous voltage indication O O O O O O O O O O O O O O O O O O O
EN61010-1 CAT III 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 600 V 600 V 600 V 600 V 600 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V
EN61010-1 CAT IV 600 V 600 V 600 V 600 V 600 V 600 V 600 V 600 V 600 V 600 V 600 V 600 V 600 V 600 V
See catalog page 15 15 16 17 17 18 18 18 19 19 19 19 19 21 21 20 22 101 101 37 37
280 Series Digital Multimeters

Advanced diagnostic and logging


functionality for maximizing productivity
Replacing the popular 180 Series, the • Logging function with TrendCapture for
Fluke 289 and Fluke 287 represent the easy review of logged data
next generation of high-performance • Multiple readings per display provide
industrial logging multimeters, more information at a glance
including higher accuracy and greater • “I”-info button for convenient on-board
troubleshooting convenience than ever help
before. With the ability to log data and • PC interface for easy data transfer
review it graphically on the large display,
you can solve problems faster and help In addition, the Fluke 289 provides:
minimize downtime, while working at • Lo Pass filter for motor drive
several locations. measurements
• LoZ – Low impedance function prevents
• Large 50,000 count 320 x 240 (1/4 VGA) false “ghost voltage” readings
dot matrix display • 50 Ω range for motor winding and low
ohm measurements

Fluke 289 Features


287 289
True-RMS measurements AC, AC+DC AC, AC+DC
Bandwidth (voltage/current) 100 kHz / 100 kHz 100 kHz / 100 kHz
Digital display counts (default/selectable) 50.000 / 50.000 50.000 / 50.000
Fluke 287
Logging function with TrendCapture O O
Records events and trends O O
Internal memory Up to 180 h Up to 180 h
Saves measurements O O
Optical USB PC communications interface O O
Low input impedance function (LoZ) O
Motor winding and low ohm measurement range 50 Ω
Low pass filter O
Field upgradeable/expandable meter O O
Navigation keys O O
F1-F4 soft keys/user function menus O O
I-info button/on board help screens O O
Multilingual interface O O
Precise performance View logged data graphically
Saves preferred measurement setups O O
on screen
Current measurement: 20 A (30 seconds momentary; 10 A continuous) O O
Peak capture (records transients as fast as 250 μs) O O
Continuity measurement O O
Min/Max/Average with Time Stamp (records signal fluctuations) O O
IP Rating 54 O O

Specifications
(Check the Fluke web for detailed specifications)
True RMS
Functions Maximum Max. resolution 287 and 289**
Voltage DC 1000 V 1 μV ±(0.025% + 5)
Voltage AC 1000 V 1 μV ±(0.4% + 40)
Included Accessories Current DC 10 A 0.01 μA ±(0.15% +2)
TL71 silicone test leads, probe holder, 6 AA Current AC 10 A 0.01 μA ±(0.7% + 5)
batteries (installed), user manual, Calibration Temperature -200 ºC to 1350 ºC 0.1 ºC ±(1.0% + 1 ºC)
Certificate Sheet. Resistance 500 MΩ 0.01 Ω ±(0.05% + 2)
Conductance 50 nS 0.01 nS ±(1.0% + 10)
Capacitance 100 mF 0.001 nF ±(1.0% + 5)
Ordering Information Frequency 1 MHz 0.01 Hz ±(0.005% + 1)
Fluke 287 True-RMS Electronic logging
Accuracies are best accuracies for each function.
multimeter with TrendCapture ** 287 and 289 accuracy and resolution are stated for 50.000 counts
Fluke 289 True-RMS Industrial logging
Battery life: 50 hours minimum, Weight: 0,871 kg
multimeter with TrendCapture
180 hours in logging mode Lifetime warranty
Fluke 289/FVF Industrial logging multimeter
Size (HxWxD): 222 mm x 102 mm x 60 mm
and Software Combo Kit
(see page 5)
Fluke 287/FVF FlukeView Forms Combo Kit
(see page 5)
Recommended Accessories
FVF-SC2 FlukeView Forms software
including IR/USB cable

TLK289 TL910 TLK287 TPAK C280


See page 111 See page 109 See page 109 See page 109 See page 118
15
233 Remote Display Multimeter

New
Ultimate flexibility with removable display
The NEW Fluke 233 remote display digital switch or an isolator switch. Wireless
multimeter allows you to be in two technology allows the display to be
places at once. The removable display carried up to 10 meters away from the
solves the problems of holding both point of measurement. The Fluke 233
the meter and the test leads to make a is also designed to work in areas where
measurement, making measurements the operator can’t be close to the active
in hard-to-reach places, and making measurement point, like clean rooms or
measurements in machines or panels hazardous areas.
that are physically separated from a limit
Features
233
Removable magnetic display O

True-RMS measurement O

Digital display counts 6000

Display backlight O

Built in thermometer O

Resistance, continuity and diode test O

Min/Max and average recording O

Auto power off maximizes battery life O

Radio transmitter automatically turns off when O


the display is connected to the meter

Use as conventional multimeter when the display is connected O

Safety rating CAT IV 600 V / CAT III 1000 V

Auto and manual ranging O

Fluke 233
Display Hold and AutoHOLD ® O

Unsafe voltage alert warns for voltages above 30V O

2 Low batteries indication O

Ergonomic case with integrated holster O

Selectable sleep mode preserves battery life O

Specifications
On all inputs
Fluke 233
Functions
Maximum Max. Resolution Accuracy
Voltage DC 1000 V 0.1 mV ±(0.25% + 2)
True RMS
Voltage AC 1000 V 0.1 mV ±(1.0% + 3)
Current DC 10 A 1 mA ±(1.0% + 3)
Current AC 10 A 1 mA ±(1.5% + 3)
Resistance 40 MΩ 0.1 Ω
Included Accessories Capacitance 9999 μF 1 nF
Test leads with 4mm lantern tips and Frequency 50.00 kHz 0.01 Hz
protective cap, AC 72 alligator clips, 80BK-A Temperature -40 ºC to +400 ºC
temperature probe, CD-ROM, AA batteries and Wireless frequency: 2.4 GHz ISM Band 10 meter range
user manual. Accuracies are best accuracies for each function

Ordering Information
Fluke 233 Remote Display Multimeter
Battery Life: AA alkaline (3 for main body, Weight: 0.6 kg
2 for display), 400 hrs typical Three year warranty
Size (HxWxD): 193 x 93 x 53 mm

Recommended Accessories

80AK-A 80PK-9 i410 Tpak C35


See page 116 See page 116 See page 115 See page 120 See page 118
16
80 Series V
Digital Multimeters

Performance and accuracy for


maximum industrial productivity
The Fluke 80 Series V have improved The Fluke 87V has a unique function
measurement functions, troubleshooting for accurate voltage and frequency
features, resolution and accuracy to solve measurements on adjustable speed
more problems on motor drives, in plant motor drives and other electrically noisy
automation, power distribution, and equipment. A built-in thermometer
electro-mechanical equipment. conveniently allows you to take
temperature readings without having to
carry a separate instrument. For 87V Ex
see also page 106 and 107.
Features
83V 87V / 87V Ex
True-RMS voltage and current for accurate O
measurements on non linear signals
Bandwidth (voltage/current) 5 kHz 20 kHz

Fluke 83V Digital display counts (default/selectable) 6000 20000 / 6000

Selectable filter for accurate voltage and frequency O


measurements on motor drives
Large display with analog bargraph and 2 level bright O O
white backlight
Auto and manual ranging for maximum flexibility O O

Built-in thermometer lets you carry one less tool O

Peak capture to record transients as fast as 250 μs O

Relative mode to remove test lead resistance from low O O


Fluke 87V ohms measurements
Min-Max-Average recording with Min/Max Alert to O O
capture variations automatically
AutoHOLD® to capture stable readings avoiding noisy O O
signals
Audible continuity, diode test and duty cycle O O

Input Alert O O

“Classic” design with new removable holster with built O O


in test lead and probe storage
83V/87V Improved selectable sleep mode for long battery life O O

Easy battery exchange without opening the complete O O


case
ATEX safety rating II 2 G Eex ia IIC T4 87V Ex

Specifications
Fluke 87V Ex
(Check the Fluke web for detailed specifications)
On all inputs
Functions Maximum Range 83V 87V/87V Ex*
Max.
Max. resolution Accuracy Accuracy
resolution
Voltage DC 1000 V 0.1 mV ±(0.1%+1) 10 μV ±(0.05%+1)
True RMS Voltage AC 1000 V 0.1 mV ±(0.5%+2) 10 μV ±(0.7%+2)
Current DC 10 A ** 0.1 μA ±(0.4%+2) 0.01 μA ±(0.2%+2)
not 87V Ex
Current AC 10 A ** 0.1 μA ±(1.2%+2) 0.01 μA ±(1.0%+2)
Resistance 50 MΩ 0.1 Ω ±(0.4%+1) 0.01 Ω ±(0.2%+1)
Included Accessories Conductance 60 nS 0.01 nS ±(1.0%+10) 0.001 nS ±(1.0%+10)
TL75 test leads, AC72 alligator clips, yellow Capacitance 9999 μF 0.01 nF ±(1.0%+2) 0.01 nF ±(1.0%+2)
holster (H80M excl. TPAK), 80BK temperature Frequency > 200 kHz 0.01 Hz ±(0.005%+1) 0.01 Hz ±(0.005%+1)
probe (87V only), 9 V battery (installed), Temperature -200 to 1090 ºC - 0.1 ºC 1.0%
CD-ROM (user’s manual and technical notes) 80BK temperature probe -40 to 260 ºC - - 2.2 ºC or 2%
and operator’s guide. Accuracies are best accuracies for each function.
* 87V accuracy is stated for 6000 counts and resolution for 20000 counts
** 20 A up to 30 seconds
Ordering Information Battery Life: Over 400 hours typical (alkaline). Weight: 0.6 kg
Fluke 83V Multimeter Size (HxWxD): 83V/87V: Lifetime Warranty
Fluke 87V True RMS Multimeter 200 mm x 95 mm x 48 mm 87V Ex: One Year Warranty
Fluke 87V Ex Intrinsically safe
True RMS multimeter Recommended Accessories
Fluke 87V/E2 Industrial Electrician Combo (Not for hazardous zones)
Kit
See page 4

C25 TL238 i410/i1010 TPAK L215


See page 118 See page 110 See page 115 See page 120 See page 111
17
170 Series Digital Multimeters

Versatile meters for field service or


bench repair
These meters have the features needed
to find most electrical, electro-
mechanical and heating and ventilation
problems.
They are simple to use and have
significant improvements over Fluke’s
original 70 Series like True-RMS, more
measurement functions, conformance to
the latest safety standards, and a much
larger display that’s easier to view.
Features
175 177 179
True-RMS measurements AC AC AC

Digital display counts, updates 4 times per second 6000 6000 6000

Display backlight O O
Fluke 177
Analog bargraph / 33 segments, updates 40 times per O O O
second
Auto and Manual ranging O O O

Display Hold and AutoHOLD® O O O

Min-Max-Average recording mode with Min/Max Alert O O O

Temperature readings (bead thermocouple probe O


included)
Smoothing mode allows filtering of rapidly changing O O O
Fluke 179 inputs
Audible continuity and diode test O O O

Test lead alert O O O

Unsafe voltage alert warns for voltages above 30V O O O

Low battery indication O O O


Fluke 175
Ergonomic case with integrated holster O O O

Easy battery and fuse exchange without opening the O O O


complete case
Selectable sleep mode preserves battery life O O O

Specifications
On all inputs
(Check the Fluke web for detailed specifications)

True RMS Functions Maximum Max. resolution 175 177 179


Voltage DC 1000 V 0.1 mV ±(0.15%+2) ±(0.09%+2) ±(0.09%+2)
Voltage AC 1000 V 0.1 mV ±(1.0%+3) ±(1.0%+3) ±(1.0%+3)
Current DC 10 A 0.01 mA ±(1.0%+3) ±(1.0%+3) ±(1.0%+3)
Current AC 10 A 0.01 mA ±(1.5%+3) ±(1.5%+3) ±(1.5%+3)
Included Accessories
Resistance 50 MΩ 0.1 Ω ±(0.9%+1) ±(0.9%+1) ±(0.9%+1)
Test leads with 4 mm lantern tips and
Capacitance 10000 μF 1 nF ±(1.2%+2) ±(1.2%+2) ±(1.2%+2)
protective cap, installed 9V battery and users
Frequency 100 kHz 0.01 Hz ±(0.1%+1) ±(0.1%+1) ±(0.1%+1)
manual. The 179 also includes the 80BK Temperature -40 ºC/+400 ºC 0.1 ºC ±(1.0%+10)
temperature probe.
Accuracies are best accuracies for each function

Ordering Information Battery Life: Alkaline, 200 hrs typical Weight: 0.42 kg
Fluke 175 True RMS Multimeter Size (HxWxD): 190 mm x 85 mm x 45 mm Lifetime Warranty
Fluke 177 True RMS Multimeter
Fluke 179 True RMS Multimeter
Fluke 179/EDA2 Kit Electronics Combo Kit
Fluke 179/MAG2 Kit Industrial Combo Kit
See page 4 Recommended Accessories

i400 C90 TLK-220 SV225 i410-i1010


See page 114 See page 118 See page 110 See page 121 See page 115
18
110 Series Digital Multimeters

Compact design for ergonomic


one-handed operation
The Fluke 110 Series has five true-rms Fluke 115 Field Service Testing
DMMs, each for specific users. The compact Multimeter
instruments offer convenient one-handed An everyday multimeter for technicians, the
operation and a backlit display with large, easy- 115 is for electrical and electronic testing in
to-read digits. field service, industrial, and applications where
more than the basic functions simplify work.
Fluke 117 Electrician’s Multimeter with
Non-Contact Voltage Fluke 114 Electrical Multimeter
The 117 is for electricians working in The 114 is for electrical troubleshooting and
commercial and non-commercial premises straightforward ‘go/no-go’ in residential/
(like hospitals and schools). It includes extras commercial testing. It has all the basic
like non-contact voltage detection for faster functions plus a special feature to prevent false
and safer operation. readings caused by ghost voltage.
Fluke 115
Fluke 116 Multimeter with Temperature Fluke 113 Multimeter
and Microamps The 113 is for basic electrical tests and
The 116 is for heating, ventilation and air repairing most electrical problems. Features
conditioning (HVAC) engineers. It includes include Fluke’s VCHEK™, added measurement
temperature measurement and microamp functions, backlight and conformance to the
current ranges to quickly troubleshoot HVAC latest safety standards.
Fluke 117
problems.
Features
113 114 115 116 117
True RMS readings AC AC AC AC AC
Counts 6000 6000 6000 6000 6000
Fluke 114
Backlight O O O O O
Analog bargraph O O O O O
AutoVolt: Automatic AC/DC voltage selection O O O
VoltAlert™, Non-contact voltage detection O
Built-in thermometer for HVAC applications O
LoZ: low input impedance to prevent ghost voltage O O O
VCHEK™ LoZ low impedance measurement function to
simultaneously test for voltage or continuity
O

Min/Max/Average to record signal fluctuations O O O O O


Resistance, continuity O O O O O
Frequency, Capacitance, Diode test -/ O/O O O O
Microamps to test flame sensors O
Display hold O O O O O
Fluke 116 Auto/manual ranging O O O O O
Low battery indication O O O O O
Compact case with removable holster O O O O O

Specifications
(Check the Fluke web for detailed specifications)
Functions Maximum Max. resolution 113 114 115 116 117
Fluke 113 Voltage DC 600V 1mV ±(0.5%+2) ±(0.5%+2) ±(0.5%+2) ±(0.5%+2) ±(0.5%+2)

On all inputs Voltage AC 600V 1mV ±(1.0%+3) ±(1.0%+3) ±(1.0%+3) ±(1.0%+3)


Current DC 10.00A 1mA ±(1.0%+3) ±(1.0%+3)
Current AC 10.00A 0.01A ±(1.5%+3) ±(1.5%+3)
True RMS
Resistance 40MΩ (113: 60KΩ) 0.1Ω ±(0.9%+2) ±(0.9%+1) ±(0.9%+1) ±(0.9%+1) ±(0.9%+1)
Capacitance 10000μF 1nF ±(1.9%+2) ±(1.9%+2) ±(1.9%+2) ±(1.9%+2)
Frequency 50kHz 0.01Hz ±(0.1%+2) ±(0.1%+2) ±(0.1%+2)
Included Accessories Temperature -40°C/+400°C 0.1°C ±(1.0%+2)
Test leads with 4 mm lantern tips and VCHEK™ 600.0V AC/DC 0.1V ±(2.0%+3)
protective cap, holster, installed 9V battery
and users manual Accuracies are best accuracies for each function

Battery type: 9 volt Alkaline, 400 hours typical Weight: 0.55 kg (including batteries)
Ordering Information Size (HxWxD): 167 mm x 84mm x 46 mm Three Year Warranty
Fluke 113 True RMS Multimeter
Fluke 114 True RMS Multimeter
Fluke 115 True RMS Multimeter Recommended Accessories
Fluke 116 True RMS Multimeter
Fluke 117 True RMS Multimeter
Fluke 117/322 Kit Electricians Combo Kit
(see page 4)
C50 TL223 MC6 TPAK
See page 118 See page 110 See page 121 See page 120
19
77IV Digital Multimeter

Versatile multimeter for field service


or bench repair
The 77-IV digital multimeter has the
features needed to repair most electrical
and electronic problems. This meter
is simple to use and has significant
improvements over Fluke’s original
70 Series with more measurement
functions, conformance to the latest
safety standards, and a much larger
display that’s easier to view.

Features
77 IV
Digital display counts 6000
Large display with backlight O
Min-Max-Average recording mode with Min/Max Alert O
High contrast digital display with large digits O
Analog bargraph/segments 31
Auto and Manual ranging O
Automatic Touch Hold® O
Audible continuity / diode test O
Ergonomic case with integrated holster O
Sleep Mode preserves battery life O
EN 61010-1 safety rating CAT IV 600 V / CAT III 1000 V

Fluke 77 IV

Specifications
Function Maximum Max. resolution Accurancy
Voltage DC 1000 V 1 mV ±(0.3%+1)
Voltage AC 1000 V 1 mV ±(2.0%+2)
Current DC 10 A 0.01 mA ±(1.5%+2)
Current AC 10 A 0.01 mA ±(2.5%+2)
Resistance 50 MΩ 0.1 Ω ±(0.5%+1)
Capacitance 9999 μF 1 nF ±(1.2%+2)
Frequency 99.99 kHz 0.01 Hz ±(0.1%+1)
Accuracies are best accuracies for each function.

Battery Life: 400 hours typical Weight: 0.42 kg


Size (HxWxD): 185 mm x 90 mm x 43 mm Lifetime Warranty

On all inputs

Included Accessories Recommended Accessories


TL75 test leads, operator’s manual, 9V battery
(installed)

Ordering Information
Fluke 77IV Multimeter i400 C35 Tpak TL225 TLK-225
See page 114 See page 118 See page 120 See page 121 See page 111
20
27II / 28II Rugged IP67 Industrial
Multimeters

Designed to survive water, dust and rough


New handling and yet troubleshoot most electrical
problems
The NEW Fluke 27 II and 28 II digital load switching and faults on industrial
multimeters define a new standard for circuits and complies with second edition
operating in harsh conditions with the IEC and ANSI electrical safety standards.
features and accuracy to troubleshoot Furthermore, the 28 II has a unique
most electrical problems. Both meters function for accurate voltage and
have IP 67 (waterproof and dustproof) frequency measurements on adjustable
rating, MSHA approvals (pending), speed motor drives and other electrically
extended operating temperature range noisy equipment.
of -15° C to + 55°C and 95% humidity, The new Fluke 20 series multimeters
and a 3-meter drop. They withstand are built to work in the toughest
hazardous 8.000 volt spikes caused by environments.

Features
27 II 28 II
IP 67 waterproof & dustproof protection O O

Withstands 3 meter drop (with holster) O O

True-RMS measurements O

Fluke 27 II
Digital display counts 6000 20000/6000

Bright, two-level backlight O O

Backlit keypad buttons O O

Reversible, rubber holster O O

Built-in thermometer O

Resistance, continuity and diode test O O

Min/Max and average recording O O

Improved sleep mode for long battery life O O

Relative mode to remove test lead resistance O O


from low ohms measurements

Auto and manual ranging O O

Safety rating CAT III 1000 V CAT III 1000 V


CAT IV 600 V CAT IV 600 V

True RMS Specifications


Max.
Functions Maximum 27 II 28 II
Fluke 28 II Resolution
Voltage DC 1000 V 0.1 mV ±(0.1% + 1) ±(0.05% + 1)
Voltage AC 1000 V 0.1 mV ±(0.5% + 3) ±(0.7% + 4)
Current DC 10 A 0.1 μA ±(0.2% + 4) ±(0.2% + 4)
Current AC 10A 0.1 μA ±(1.5% + 2) ±(1.0% + 2)
Temperature -200 ºC to
+1090 ºC
Resistance 0.1 Ω to 50 MΩ
Low pass filter (Measurement on VSD’s) yes
Capacitance 1 nF to 9999 μF
On all inputs
Frequency 0.5 Hz to 199.99 kHz
Peak transient capture 250 μS
Accuracies are best accuracies for each function

Battery Life: 3x AA alkaline, 800 hrs typical Weight: 0.75 kg


Size (HxWxD): 198 x 100 x 63.5 mm Lifetime Warranty
Included Accessories
TL 75 Test leads, AC 72 alligator clips, 80BK-A
temperature probe (28 II), holster, manual, Recommended Accessories
CD-ROM, three AA batteries (installed)

Ordering Information
Fluke 27 II IP 67 Industrial Multimeter
Fluke 28 II IP 67 True-RMS Industrial Multimeter
PV 350 i200 i410 80K-6
See page 113 See page 114 See page 115 See page 121 21
88V Automotive Meter

The right meter for auto-electric diagnosis


Perhaps the most important tool you’ll
use in troubleshooting auto electrical
systems is the multimeter. Basic
multimeters measure voltage, current
and resistance, while automotive
multimeters like the Fluke 88V have
features that can check frequency, duty
cycle, make diode tests, and measure
temperature, pressure and vacuum.
Features
88V/A
Continuity for detecting open and shorts O

Frequency for “pulsed-DC” and AC tests O

Duty cycle to verify operation of feedback carburetors O

Diode test for alternator testing O

Built-in thermometer; thermocouple probe included O

Min/Max/Average recording with Min/Max Alert O

Peak capture to record transients as fast as 250 μs O


Fluke 88V/A
Relative mode to remove test lead resistance from low ohms measurements O

Millisecond pulse width measurements for fuel injectors O

AutoHOLD® to capture stable readings O

Large display with bright, two-level backlight O

Magnet hanger to attach meter to the vehicle O

RPM80 Inductive Pickup for both conventional and distributorless (DIS) ignitions O

Hard Meter Case O

Safety rating CAT III 1000 V,


CAT IV 600 V

Specifications
On al inputs Fluke 88V
Range Resolution Accuracy
Voltage DC 1000V 0.1mV 0.1%
Voltage AC 1000V (5 kHz) 0.1mV 0.5%
Current DC 10A 0.1μA 0.4%
Current AC 10A 0.1μA 1.2%
Resistance 50MΩ 0.1Ω 0.4%
Capacitance 10mF 0.01nF 1%
Included Accessories Frequency 200kHz 0.01Hz 0.005%
H80M Holster with TPAK Meter Hanging Temperature 1090ºC 0.1ºC 1%
Solution, TL224 SureGrip Silicone Test Lead
Set, TP220 SureGrip Test Probe Set, AC285
SureGrip Large Jaw Alligator Clip Set, 80BK Battery Life: 88V – Over 400 hours typical Weight: 88V – 0.36 kg
Integrated Temperature Probe, RPM80 (alkaline) Lifetime Warranty
Inductive Pick-up Probe, C800 Hard Case, Size (HxWxD): 88V – 186 mm x 86 mm x 32 mm
User’s Manual + Quick Reference Guide

Ordering Information
Fluke 88V/A Automotive Meter Combo Kit
Recommended Accessories

TL82 TLK-282 90i-610s 80PK-27 (requires 80AK) PV350


See page 113 See page 113 See page 113 See page 116 See page 113
22
8845A/8846A
6.5 Digit Precision Multimeters

Precision and versatility for bench or


systems applications
The Fluke 8845A and 8846A, 6.5 digit Perform 4-wire measurements easily
precision multimeters have the precision with two leads: Patented split terminal
and versatility to handle your most jacks for 2x4 Ohms function allows you
demanding measurements on the bench to perform precise 4-wire measurements
or in a system. with only two leads instead of four.
Optional Kelvin leads accessories are
Dual Display offers versatile graphical available to enable you to establish a 4-
Fluke 8845A capabilities: The 8845A and 8846A wire connection even in tight spaces.
features a unique graphical display that Systems Capabilities: Both instruments
can reveal signal quality issues like drift, include an RS-232, IEEE-488 and Ethernet
intermittent and stability by viewing interface as standard, with popular
the measurement data as a real time DMM emulation modes makes systems
TrendPlot™, Histogram or Statistics integration a simple task.
using the unique analyze mode. Software: Transfer data points from your
Wide Measurement Ranges: Resistance meter to your PC with the free copy of
or current has been extended to cover FlukeView Forms Basic. To customize
the widest range possible. your forms upgrade with FVF-UG.

Fluke 8846A

Features
8845A 8846A
Display Dual VFD Dot Matrix
Resolution 6.5 Digits
Measurement Rate (Rdgs/s) 1000
Use the built-in TrendPlot paperless chart recorder to Continuity / Diode Test Yes
graphically identify the extent of drift and intermittent Analytical Functions Statistics, Histogram, TrendPlot™, Limit Compare
events in analog circuits Math Functions NULL, Min/Max, dB/dBm
USB Device Port – USB Memory Drive port
Real Time Clock – Yes
Interfaces RS232, IEEE-488.2, Ethernet
Programming Languages/ SCPI (IEEE-488.2), Agilent 34401A, Fluke 45
Emulation Modes
Safety Designed to comply with IEC 61010-12000-1, ANSI / ISA-S82.01-1994, CAN /
View results in Histogram mode to reveal stability or CSA-C22.2 No.1010.1-92 1000V CATI / 600V CATII
noise problems in analog circuits

Specifications
(Check the Fluke web for detailed specifications)

8845A 8846A
Handle even the most demanding measurements with Function* Range Resolution Accuracy* (%) Range Resolution Accuracy* (%)

high accuracy and 6.5 digit resolution Voltage DC 1000 V 100 nV 0.0035 1000 V 100 nV 0.0024
Voltage AC (Freq 300 Hz) 750 V 100 nV 0.06 1000 V 100 nV 0.06
Resistance (2x4 Wire) 100 MΩ 100 μΩ 0.01 1 GΩ 10 μΩ 0.01
Current DC 10 A 100 pA 0.05 10 A 100 pA 0.05
True RMS Current AC (Freq. 3Hz-10kHz) 10 A 10 μA 0.10 10 A 100 pA 0.10
Freq/Period 300 kHz 1 μHz 0.01 1 MHz 1 μHz 0.01
Capacitance - - - 1 nF to 0.1 F 1 pF 1
Temperature RTD - - - -200 to +600º 0.001º 0.06
Included Accessories * Accuracy =+/- (% of reading)
LCI Line Power Cord, TL71 Test Lead Set,
Spare Line Power fuse, Programmers Manual/ Size (HxWxD): 88 mm x 215 mm x 293 mm
User Manual on CD-ROM, 884X-USB USB to Weight: 3.6 kg
RS232 Cable Adapter, FVF-BASIC FlukeView Three Year Warranty
Forms Software Basic Version.

Ordering Information Recommended Accessories


Fluke 8845A 6.5 Digit Precision Multimeter
Fluke 8845A/SU 6.5 Digit Precision
Multimeter (software + cable)
Fluke 8846A 6.5 Digit Precision Multimeter
Fluke 8846A/SU 6.5 Digit Precision
Multimeter (software + cable) 884X-case
Hard case
TL2X4W-TWZ
2x4 Wire Ohms Tweezer
TL2X4W-PT II
2x4 Wire Ohms Test
884X-512M
USB Memory 512M
FVF-UG
FlukeView Forms
Calibration & Service agreements Test Leads lead 2mm Probe Tip Software Upgrade
23
8808A 5.5 Digit Multimeter

Versatile multimeter for manufacturing,


development and service applications
Manufacturing test, R&D, development Eliminate production mistakes: The
and service applications demand 8808A has a limit compare mode with
performance and flexibility from a built in display enunciators that clearly
bench meter. The Fluke 8808A delivers a show whether a test is within or out of
wide variety of measurement functions, limits.
including volts, ohms, and amps, plus
frequency - all at superior accuracy and Perform 4-wire measurements with
resolution with a basic V dc accuracy of only two leads: Patented split terminal
Fluke 8808A 0.015 %. jacks for 2x4 Ohms function allow you
to perform precise 4-wire low ohms
Measure sensitive leakage current: The measurements with only two leads
Fluke 8808A includes two low impedance instead of four. Optional test lead
low current ranges for measuring accessories are available to enable you
sensitive leakage currents (i-Leakage). to establish a 4-wire connection even in
tight spaces or on surface mount devices.
Perform routine manufacturing
functional tests with consistency:
Use setup keys (S1 – S6) for fast access to
repetitive measurements. Operators no
longer need to press multiple buttons to
The Fluke 8808A includes two low impedance low make routine measurements.
current ranges for measuring sensitive leakage
currents
Features
8808A
Display VFD multi segment
Resolution 5.5 digits
Measurements V ac, V dc, I dc, I ac, Ω, Cont, Diode
Advanced Measurements 2X4 Wire Ohms, Freq, i-Leakage
Continuity / Diode Test Yes
Analytical Functions Limit Compare
Math Functions dBm, dB, Min, Max
Interfaces RS-232, USB via optional adapter
Programming Languages/Modes Simplified ASCI, Fluke 45
Use setup keys (S1-S6) for fast access to repetitive
Safety Rating CAT I 1000 V, CAT II 600 V
measurements. Setups can include limit compare mode
with pass/fail indicators

Specifications
(Check the Fluke web for detailed specifications)

Functions Range Resolution Accuracy*


Voltage DC 200 mV to 1000 V 1 μV 0.015
Voltage AC 200 mV to 750 V 1 μV 0.2
Dual Display (Freq. 10 Hz to 100 kHz)
Resistance (2x4 Wire) 200 Ω to 100 MΩ 1 mΩ 0.02

Current DC 200 μA to 10 A 1 nA 0.02

Current AC 20 mA to 10A 100 μA 0.3


True RMS (Freq. 20 Hz to 2 kHz)
Freq. Period 20 Hz to 1 MHz 0.1 mHz 0.01
(Freq. only)

Included Accessories * Accuracy = +/- (% of reading)

LCI Line Power Cord, TL71 Test Lead Set, Spare


Line Power fuse, 884X-USB USB to RS232 Cable Size (HxWxD): 88 mm x 217 mm x 297 mm
Adapter, FlukeView Forms Software Basic Weight: 2.1 kg
Version, Programmers Manual/User Manual Three year Warranty
on CD-ROM.

Ordering Information Recommended Accessories


Fluke 8808A 5.5 digit multimeter
Fluke 8808A/SU 5.5 digit multimeter,
(software & cable)
Fluke 8808A/TL 5.5 digit multimeter,
2X4W Test Lead Kit
TL2X4W-TWZ 884X-case TL2X4W-PT II 884X-short FVF-UG/SC4/SC5
2x4 Wire Ohms Tweezer Hard case 2x4 Wire Ohms Test 4-Wire Short FlukeView Forms
Test Leads lead 2mm Probe Tip Software
24
Clamp Meters and
Electrical Testers

The ergonomic clamp meters feature wide opening jaws for safe, fast
non-contact current measurement. The Fluke leakage clamp meter is
ideal for non-invasive checks of insulation resistance.
The range of electrical testers includes two-pole testers for taking
quick measurements in tight spaces, phase rotation indicators to
take the guess work out of checking phase/motor rotation, a
multipurpose cable locator and handy voltage alerts.

25
330 Series/902 Clamp Meters

Expanded capabilities for current


measurement
The Fluke 330 Series Clamp Meters offer The Fluke 902 adds temperature and
all the features you need to fit the way capacitance measurement capabilities to
you work. The small body and jaws fit the line, ideal for heating, ventilation and
perfectly in your hand and into tight air conditioning system inspections.
places. Meter controls are positioned so
that current measurements can be down
with one hand. A large backlit display (on
most models) is easy to see and a handy
Display Hold keeps measurements on the
display. Measuring starting current for
motors, lighting, etc. is easy with the in-
Fluke 336 Fluke 335 rush current function (on most models).
Features
Functions 333 334 335 336 337 902
True-RMS O O O O
Display backlight O O O O O
Auto shut-off O O O O O O
Display Hold O O O O O O
Motor start-up current O O O O
Low battery indication O O O O O O
Large jaw O O
Min/Max O O
Current AC/DC O O O*
Temperature O

Fluke 334 Fluke 333


* DC A: 0-200 μA direct measurement

Fluke 337

Specifications
Functions Range 333 334 335 336 337 902
Current AC 0-400.0A 2% ± 5 counts
0-600.0A 2% ± 5 counts 2% ± 5 counts 2% ± 5 counts 1% ± 5 counts
0-999.9A 2% ± 5 counts
Crest Factor 0-600.0A 2.4 @ 500A 3 @ 500A 2.4 @ 500A
2.0 @ 600A 2.5 @ 600A 2.0 @ 600A
0-999.9A 3 @ 500A
2.5 @ 600A
1.42@ 1000A
Current DC 0-200 μA 1% ± 5 counts
0-600.0A 2% ± 5 counts
Fluke 902
0-999.9A 2% ± 5 counts
In-rush Integration
100mS 100mS 100mS 100mS
True RMS Current time
Voltage AC 0-600.0V 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts
Voltage DC 0-600.0V 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts
Resistance 0-600.0Ω 1.5% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts

Included Accessories 0-6000Ω 1.5% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts
0-9999Ω 1.5% ± 5 counts
C33 Soft case, TL75 test leads, 80BK Integrated
Continuity ≤ 30Ω ≤ 30Ω ≤ 30Ω ≤ 30Ω ≤ 30Ω ≤ 30Ω
DMM temperature probe (902),
Frequency 5-400Hz 0.5% ± 5 counts
2 AA alkaline batteries, instruction card and Temperature -10° to 400°C 1% ± 0.8°C
safety information sheet. Capacitance 1μF to 1000μF 1.9% ± 2 counts

Ordering Information Battery Life: Alkaline, 150 hours Jaw Opening: 30 mm (333, 334, 335 and 902)
Fluke 333 Clamp Meter Size (HxWxD): 42 mm (336, 337)
Fluke 334 Clamp Meter 238 mm x 79 mm x 41mm (333, 334, Weight: 0.312 kg
Fluke 335 True-RMS Clamp Meter 335 and 902) Three Year Warranty
Fluke 336 True-RMS Clamp Meter 251 mm x 79 mm x 41 mm (336 and 337)
Fluke 337 True-RMS Clamp Meter
Fluke 902 True-RMS Clamp Meter Recommended Accessories
(HVAC)

H3 TL223 L215
See page 119 See page 110 See page 111
26
320 Series Clamp Meters

Big features, small package


The Fluke 321 and 322 are designed Model 322 also offers DC voltage
to verify the presence of load current, measurements and has a higher
ac voltage and continuity of circuits, resolution for loads below 40 A.
switches, fuses and contacts. These small
and rugged clamp meters are ideally
suited for current measurements up to
400 A in tight cable compartments.

Features
Functions 321 322
Compact design O O
Auto shut-off O O
Display Hold O O
Low battery indication O O
Current AC O O
Volts DC O

Fluke 322

Specifications
321 322 321 322
Fluke 321 Functions Range Resolution Range Resolution Best Accuracy
Current AC 400.0A 0.1A 40.00A 0.01A 1.8% ± 5 counts 1.8% ± 5 counts
400.0A 0.1A (50 - 60Hz) (50 -60Hz)
3.0% ± 5 counts 3.0% ± 5 counts
(60Hz - 400Hz) (60Hz - 400Hz)
Voltage AC 0-400.0V 0.1V 0-400.0V 0.1V 1.2% ± 5 counts 1.2% ± 5 counts
400-600V 1V 400-600V 1V (50-400Hz) (50-400Hz)
Voltage DC 0-400.0V 0.1V 1% ± 5 counts
400-600V 1V
Resistance 0-400.0Ω 0.1Ω 0-400.0Ω 0.1Ω 1% ± 5 counts 1% ± 5 counts
Continuity ≤ 30Ω ≤ 30Ω

Battery Life: 100 hours typical Weight: 0.23 kg


(2 AAA carbon zinc) Two Year Warranty
Included Accessories Size (HxWxD): 190 mm x 63 mm x 35 mm
C23 Soft carrying case, TL75 test leads, Jaw Opening: 25 mm
(2) AA alkaline batteries, coated instruction
card, safety information sheet.
Combo Kit
Ordering Information
Fluke 321 Clamp Meter Fluke 62/322/1AC Kit Fluke 117/322 Kit
Fluke 322 Clamp Meter • Fluke 62 Infrared See page 4
Fluke 117/322 Kit Electricians Combo Kit Thermometer
Fluke 62/322/1AC IR Thermometer, Clamp • Fluke 322 Clamp Meter
Meter and Voltage • Fluke 1AC II Volt Alert
Detector Kit
Recommended Accessories

H3 TL223 L215
See page 119 See page 110 See page 111
27
350 Series AC/DC Clamp Meters

True-RMS, 2000 A Clamp Meters


for industrial and utility applications
Confidently take reliable readings with Accurate peak measurements can be
the true-rms, Fluke 353/355 Clamp taken using the in-rush current mode -
Meters; the tools of choice for high ideal for motors and inductive loads. The
current measurement up to 2000 A. The 355 also measures voltage and resistance,
extra-wide jaw easily clamps around making this the most versatile tool
large conductors, typically found in high for utilities, electrical contractors and
current applications. The rugged design industrial service technicians.
and CAT IV 600 V,
CAT III 1000 V ratings add an extra
element of protection when taking
high-powered measurements.

Features
353 355
True-RMS measurements O O
Display backlight O O
Motor start-up current O O
Min/Max/Average O O
Voltage AC/DC O
Fluke 353 Resistance measurement O
Continuity measurement with beeper O

Specifications
(Check the Fluke web for detailed specifications)

Fluke 355 Functions Range 353 355


Current AC/DC 0-40.00 A 1.5% ± 15 counts 1.5% ± 15 counts
0-400.0 A
1.5% ± 5 counts 1.5% ± 5 counts
0-2000 A; 1400 AC rms
Crest Factor 2.4 2.4
Voltage AC/DC 0-4.000 V 1% ± 10 counts
0-40.00 V
0-400.0 V
1% ± 5 counts
0-600 V AC rms
0-1000 V DC
Resistance 0-400.0 Ω
0-4.000 kΩ
0-40.00 kΩ 1.5% ± 5 counts
0-400.0 kΩ
Continuity beeper Appr. ≤ 30 Ω
Frequency 5.0Hz to 100.0Hz 0.2% ± 2 counts
True RMS 100.1Hz to 999Hz 0.5% ± 5 counts

Included Accessories
Fluke 353: C43 Soft Meter Case, 6 AA batteries, Power Supply: 6 x 1.5V AA NEDA 15A Size (HxWxD): 300 mm x 98 mm x 52 mm
users manual or IEC LR6 Jaw opening: 58 mm
Fluke 355: C43 Soft Meter Case, 6 AA batteries, Battery Life: 100 hours (with typical Weight: 0.814 kg
TL224 SureGrip® Silicone Test Lead Set, TP2 usage, backlight off) Two year warranty
Slim Reach Test Probe Set (2 mm), AC285
SureGrip® Alligator Clip Set, users manual

Ordering information
Fluke 353 AC/DC Clamp Meter
Fluke 355 AC/DC Clamp Meter Recommended Accessories

TL223 (Fluke 355) L215 (Fluke 355)


See page 110 See page 111
28
360 Leakage Clamp Meter

Leakage current measurements with a tough,


pocket sized clamp meter
The Fluke 360 is ideal for non-invasive Features
checks of insulation resistance. • Measurement of leakage protectives
The unique jaw design eliminates the conductor and touch current with a
influence of adjacent current conductors. resolution of 1μA
The ergonomic design of the Fluke 360 • Advanced shielding to ensure accurate
ensures easy measuring. The measuring results when measuring near other
clamp fits into tight spaces and the conductors
wide display angle clearly shows the • Automatic ranging within the manually
measurement result. The data hold selected mA or A range
button keeps the measured value on the • Easily viewed measurements on digital
display after removing the clamp for the and bargraph display and HOLD when
measured conductor. measuring in hard to see locations
• Broad range of measurements currents
The light Fluke 360 offers the widest up to 60 A for all installation needs
range of current measurement for • Easy carrying, pocket sized clamp with
maintenance professionals and wide 40 mm jaw size
contractors. • Display-Hold for convenience in use
• Auto power off with audible warning
buzzer
• Conformance to IEC61010 and EMC
standard
• Meets all the applications and
performance classes in safety standard
VDE0404-4 and the new VDE0702

Fluke 360

Specifications
(Check the Fluke web for detailed specifications)

Functions Range Resolution Accuracy


3mA 0.001A
Current AC 1% ± 5 counts
30mA 0.01mA
30A 0.01A 1% ± 5 counts (0~50A)
60A 0.1A 5% ± 5 counts (50~60A)
Frequency 50 and 60Hz

Battery type: 3 Volt Lithium, 90 hours typical


Size (HxWxD): 176 mm x 70mm x 25 mm
Weight: 0.2kg
One Year warranty

Included accessories
Soft carrying pouch and users manual display: 1.7mA

Ordering information leakage


Fluke 360 Leakage Clamp Meter current 0.5mA

ground leakage current


1.2mA (e.g. via
motor shaft)

29
T100 Series
Voltage and Continuity Testers

The fast and easy solution to voltage,


continuity and phase rotation testing
The fast and easy solution to voltage, Moreover they have a special electrical
continuity and resistance measurements. torch function for working in low light
Ideal for site conditions, the 3 models level environments and have an ingress
of the T100 Series 2-pole testers have a protection rating of IP65. The T100 Series
rugged construction and ergonomically are compliant with EN 61010-1 and
formed housing for perfect handling. EN61243-3 requirements.
All models offer a patented three-phase
rotation detection system providing
quick phase rotation indication.

Fluke T120

Features
T100 T120 T140
Display LCD LCD
Led Bargraph 12 LED’s 12 LED’s 12 LED’s
Backlight O
Resistance measurement O
Switchable load O
Voltage test O O O
Fluke T140
Optical and acoustical continuity test O O O
Rotary field indication O O O
Single pole test for phase detection O O O
Indication of polarity O O O
Fluke T100 Electrical torch function O O O
Probe tip protection O O O
The voltage display also functions when using O O O
discharged - or o batteries

Specifications
T100 T120 T140
Voltage AC/DC 12 - 690 V 12 - 690 V 12 - 690 V
Continuity 0 - 400 kΩ 0 - 400 kΩ 0 - 400 kΩ
Frequency 0 - 400 Hz 0 - 400 Hz 0 - 400 Hz
Phase rotation 100 to 690 V 100 to 690 V 100 to 690 V
Resistance measurement - - Up to 1999 Ω
Included Accessories Response time < 0.1 s < 0.1 s < 0.1 s
Two 1.5V batteries and instruction sheet

Ordering Information
Fluke T100 Voltage/Continuity Tester
Size (HxWxD): 240 mm x 56 mm x 24 mm
Fluke T120 Voltage/Continuity Tester Case: IP65 (water-jet and dust tight protection)
Fluke T140 Voltage/Continuity Tester Weight: 180 g
Two year warranty
UK versions are compliant with GS38

Recommended Accessories

C33 (T100 Series)


See page 118
30
T5 Electrical Testers

The fast and easy solution to basic


electrical testing
The Fluke T5 testers let you check
voltage, continuity and current with
one compact tool. Select volts, ohms or
current and the instrument does the rest.
Model T5-600 measures 600 volts
AC/DC, model T5-1000 is designed for
1000 volts. OpenJaw™ current technology
lets you check current up to 100 A,
without breaking the circuit. The optional
H5 holster keeps the test probes and
leads ready to test and lets you clip the
T5 onto your belt.

Features and Specifications


T5-600 T5-1000
Display Count 1000 1000
Fluke T5-1000 Fluke T5-600 Automatic Selection O O
Continuity and Bleeper O O
Sleep Mode O O
AC Voltage 600 V 1000 V
DC Voltage 600 V 1000 V
AC Current 100 A 100 A
Resistance 1000 Ω 1000 Ω
Safety range 600V CAT III 1000 V CAT III / 600 V CAT IV

Battery life: 400 hours Weight: 0.38 kg


Size (HxWxD): Two year warranty
203 mm x 51 mm x 30.5 mm

Fluke T5-H5-1AC Kit Fluke T5-600/62/1AC Kit

The ideal kit for busy electrical This kit is designed to help electricians
contractors and electricians. The benefits and HVAC technicians solve problems
of a voltage and current meter and non- quicker. Test first for overheated electrical
Fluke T5-H5-1AC Kit
contact voltage detector all in one kit. A devices using an IR thermometer; then
holster for the T5 is also included. use elecrtrical test tools to find out more
about the problem.
Kit includes:
- Fluke T5-1000 Kit includes:
- H5 holster • Fluke T5-600
Fluke T5-600/62/1ACII Kit - Free Fluke 1AC-II • Fluke 62
• Fluke 1AC II
• C115
Included Accessories
TP4 4 mm detachable probes (detachable GS38
probes for the UK) and instruction sheet

Ordering Information
Fluke T5-600 Electrical Tester
Fluke T5-1000 Electrical Tester
Fluke T5-H5-1AC Kit Electrical Tester with
holster and IAC
Fluke T5-600/62/1AC Electrical Tester,
IR Thermometer,
Voltage Detector Kit
Recommended Accessories

H5 ACC-T5-Kit AC285
See page 119 See page 111 See page 112
31
1AC II Volt Alert
LVD1/LVD2 Volt Lights
SM100/200/300 SocketMaster-testers

Fluke 1AC II VoltAlert™


The Fluke VoltAlert AC voltage detector is Operating range: 200 – 1000 V AC
very easy to use – just touch the tip to a Batteries: Two AAA Alkaline
terminal strip, outlet or cord. When the tip Size (H): 148 mm
glows red and the unit beeps, you know Two Year Warranty
there is voltage on the line.
• It continually tests its battery and its Fluke 1AC II VoltAlert™ 5-pack
circuit integrity with a periodic double • Buy 4 get 1 FREE
Fluke 1AC II flash visual indication.
• Highest safety rating: CAT IV 1000 V
• Detects voltage without metallic contact

LVD1 Volt Light


Dual sensitivity voltage detector
• Detects voltage from 40 V to 300 V AC
• Blue light means you’re close
• Red light means you’re at the source
• Comes with a versatile clip to secure light to
pocket, hat or even panel door
LVD1

LVD2 Volt Light


Combines bright light and voltage detection in one pen style design
• Dual sensitivity
• Detects voltage from 90 V to 600 V AC
• Blue light means you’re close
• Red light means you’re at the source
LVD2
• Rated to CAT IV 600 V

SM100/200/300 SocketMaster Testers


The fast way to check if your sockets are safe.

Ordering Information
Fluke 1AC II VoltAlert
Fluke 1AC II 5PK VoltAlert (5-pack)
LVD1 Volt Light
LVD2 Volt Light
SM100 SM200 SM300
SM100 SocketMaster Tester
SM200 SocketMaster Tester
SM300 SocketMaster Tester
Only available with UK plug
Features
SM100 SM200 SM300
Clear indication of wiring status O O O
Audible notification of wiring status O O
Unique soft-touch RCD test checks 30 mA RCD´s for trip O
within 300 ms
Earth Volts Touchpad detects raised earth voltages >50 V, O
indicating potentially dangerous situations

32
9040/9062
Phase Rotation Indicators

Take the guess work out of phase/motor


rotation measurements
Fluke 9040 Fluke 9062
The Fluke 9040 is effective for measuring The unique Fluke 9062 provides rotary
phase rotation in all areas where field and motor rotation indication with
three-phase supplies are used to feed the benefits of contact-less detection.
motors, drives and electrical systems. Purpose made for commercial and
The Fluke 9040 is a rotary field indicator industrial environments, the Fluke 9062
and can provide clear indication of the provides rapid indication of 3 phase
3 phase via an LCD display and the rotation using test leads supplied or can
phase rotation direction to determine be used to determine motor rotation on
correct connections. It allows rapid synchronous and asynchronous 3 phase
determination of phase sequence motors. The contact-less detection is
and has a voltage (up to 700 V) and ideal for use on motors where the shaft is
frequency range suitable for commercial not visible.
and industrial applications. Test probes Test probes supplied with the instrument
supplied with the instrument have a have a variable clamping range for safe
variable clamping range for safe contact, contact, especially in industrial sockets.
especially in industrial sockets.

Fluke 9040
Features
9040 9062
3 phase indication Via LCD Via LED
Indication of phase rotation O O
Indication of motor rotation direction O
Contact free determination of the rotation direction of running motors O
Clear LCD display O
No battery required O

Fluke 9062

9040:

Specifications
9040 9062
Voltage range 40 - 700 V Up to 400 V
Phase display - 120 - 400 V AC
Frequency range 15 - 400 Hz 2-400 Hz
9062:
Operating time Continuous Continuous

Size (HxWxD) Fluke 9040: Power supply 9040: from unit under test
124 mm x 61 mm x 27 mm Power supply 9062: 1 x 9V
Size (HxWxD) Fluke 9062: Weight 9040: 0.20 kg
124 mm x 61 mm x 27 mm Weight 9062: 0.15 kg
Two Year Warranty

Included Accessories Fluke 9062 Applications


Fluke 9040: Alligator clips - black (3)
Flexible test probes - black (3)
Fluke 9062: Alligator clips - black (3)
Flexible test probes - black (3)
Test leads - black (3)

Ordering Information Determine the presence of Determine the rotation of Check the correct rotation of
Fluke 9040 Phase Rotation Indicator phase sequence of multiphase running motors simply by motors prior to connection.
Fluke 9062 Motor and Phase Rotation electrical supplies. placing the instrument on
Indicator the motor casing.

Recommended Accessories

TLK290 TLK291 C25


See page 111 See page 111 See page 118
33
2042 Cable Locator

The multipurpose solution to cable location


The Fluke 2042 is a professional general • Receiver with a backlight LCD-display
purpose cable locator. It is ideal for for level of receiving signal, code
tracing cables in walls and underground, of receiving signal and live voltage
locating fuses/breakers on final circuits indication
and locating interruptions and short- • Automatic or manual adjustment of
circuits in cables and electrical floor receiving signal sensitivity
heating systems. • Switchable acoustic receiving signal
It can also be used for tracing metallic • Auto-Power-Off
water and heating pipes. The unit is • Additional torch lamp function for
supplied as a complete kit comprising of working in dark environments
a transmitter and receiver in a purpose- • Additional transmitters are available
made carry case. The receiver also for extension or to distinguish between
incorporates a torch function for working several signals.
in dimly lit locations.

• For all applications (live or dead cables)


without additional instruments
• Set includes a transmitter and a
Transmitter receiver
• Proven digitally coded sender signal
guarantees clear signal identification
Receiver
• Transmitter with LCD-display for
transmitting level, transmitting code
and external voltage
Fluke 2042 Specifications
Transmitter Receiver
Voltage Measurement Range 12V, 50V,120V, 230V, 400V
Frequency Range 0..60 Hz
Output signal 125 kHz
Voltage Up to 400V AC/DC
Tracing depth cable location 0...2.5m wall/underground
cables
Main voltage detection 0...0.4m

Batteries Transmitter: 6 pc Batteries 1.5V


Batteries Receiver: 1 pc Battery 9V
Size (HxWxD) Transmitter:
190 mm x 85 mm x 50 mm
Size (HxWxD) Receiver:
250 mm x 65 mm x 45mm
Weight Locator: 0.45 kg
Weight Receiver: 0.36 kg
Two Year Warranty

Fluke 2042 applications

Included Accessories
TL27 Heavy Duty Test Lead Set (2)
TP74 Lantern Tip Test Probe Set
AC285 Alligator Clip Set
Soft carrying case
Hard case
Location of fuses/breakers Tracing of underground Precise location of cable
and assignment to circuits cables (max. depth 2.5 m) interruptions with additional
Ordering Information transmitter
Fluke 2042 Cable Locator
(transmitter + receiver)
Fluke 2042T Cable Locator Transmitter

Recommended Accessories

Fluke 2042T

34
Insulation Testers and
Earth Ground Testers

With a 5000 V MegOhmMeter for industrial-strength insulation testing


and a range of compact hand-held instruments, we offer a solution
for every troubleshooting and preventive maintenance application.
Two of the digital hand-held insulation testers also include full-featured
multimeters.
The Fluke Earth Ground Testers can perform all four types of earth
ground measurement, including stakeless testing with earth ground
loop resistances using only clamps.

35
Insulation Tester
Selection Guide

1577 1587 1587T 1503 1507 1550B


InstallationTest Functionality
Test voltages 500V, 1000V 50V, 100V, 250V, 500V, 50V, 100V 500V, 1000V 50V, 100V, 250V, 500V, 250V, 500V, 1000V,
1000V 1000V 2500V, 5000V
Insulation Resistance Test Range 0.1MΩ - 600MΩ 0.01 MΩ - 2GΩ 0.01MΩ - 100MΩ 0.1MΩ - 2GΩ 0.01MΩ - 10GΩ 200KΩ - 1TΩ
Polarization Index/Dielectric Absorption Ratio O O
Auto Discharge O O O O O O
Time Ramp test (Breakdown) O
Pass/Fail Comparison O
Estimated Number of 1000 1000 1000 1000 1000
Insulation resistance Tests
Voltage > 30V Warning O O O O O O
Memory (99 locations)
Remote Test Probe O O O O O
Lo Ohms O O
Display Digital LCD Digital LCD Digital LCD Digital LCD Digital LCD Digital LCD / Analog
Bar Graph
Continuity O O O (200mA) (200mA)

Multimeter Functionality
AC/DC Volts O O O O O
Current O O O
Resistance O O O O O
Temperature (contact) O O
Lo-Pass Filter O O
Capacitance O O O
Diode Test O O
Frequency O O
MIN/MAX
O O
Other
Hold/Lock O O O O O O
Backlight O O O O O
(Fluke View® Forms
Software
Basic)
Warranty (in years) 3 3 3 1 1 2
4 AA (NEDA 15A or 4 AA (NEDA 15A or 4 AA (NEDA 15A or 4 AA (NEDA 15A or 4 AA (NEDA 15A or
Battery Rechargeable
IEC LR6) IEC LR6) IEC LR6) IEC LR6) IEC LR6)

Buy a Fluke 1587 Combo Kit and save


Fluke 1587/ET Advanced Electrical Fluke 1587/MDT Advanced Motor
Troubleshooting Kit & Drive Troubleshooting Kit

This kit contains: This kit contains:


• Fluke 1587 Insulation Multimeter • Fluke 1587 Insulation Multimeter
• Fluke 62 Mini Infrared Thermometer • Fluke 9040 Phase Rotation Indicator
• i400 Current Clamp • i400 Current Clamp
Fluke 1587/ET
Perform insulation tests with the Fluke Perform insulation tests with the Fluke
1587 plus a wide-range of DMM tasks with 1587 plus a wide-range of DMM tasks with
confidence and ease. Use the i400 with your confidence and ease. Use the i400 with your
Fluke 1587 to accurately measure AC current Fluke 1587 to accurately measure AC current
without breaking the circuit. Check for hot without breaking the circuit. Check the phase-
spots and measure temperature with the rotation of three-phase motors easily and
Fluke 62 Mini non-contact thermometer. safely with the Fluke 9040.

Fluke 1587/MDT
36
1503/1507 Insulation Testers

Truly portable insulation resistance testers


When you need a low cost solution to The multiple test voltages on both
general purpose insulation testing look models make them ideal for many
no further than the new Fluke insulation troubleshooting, commissioning and
tester range. The Fluke 1507 and 1503 preventive maintenance applications.
Insulation Testers are compact, rugged, Additional features like the remote
reliable and easy to use. probe save both time and money when
performing tests.

Features
1503 1507
User selectable test voltages for many applications O O
Additional test voltages 50V, 100V, 250V O
Special remote control probe for easy and safe measurements O O
Auto-discharge of capacitive voltage for added user protection O O
Fluke 1503 Live circuit detection prevents insulation test if voltage > 30 V O O
is detected for added user protection
Save both time and money with Automatic calculation of O
Polarization Index and Dielectric Absorption Ratio
Auto Power off to save batteries O O
Large display with backlight O O
Continuity function (200 mA) O O
Compare function (pass/fail) for fast repetitive tests O

Fluke 1507

Specifications
Insulation specifications 1503 1507
Insulation test range 0.1 MΩ to 2 GΩ 0.01 MΩ to 10 GΩ
Test voltages 500 V, 1000 V 50 V, 100 V, 250 V, 500 V, 1000 V
Test voltage accuracy + 20 %, - 0 % + 20 %, - 0 %
Insulation test current 1mA nominal 1mA nominal
AC/DC Voltage measurement 600 V (0.1 V resolution) 600 V (0.1 V resolution)
Resistance measurement range 0.01 Ω to 20 kΩ 0.01 Ω to 20 kΩ
Auto discharge Discharge time < 0.5 second Discharge time < 0.5 second
for C = 1 μF or less for C = 1 μF or less
Maximum capacitive load Up to 1 μF Up to 1 μF
Open circuit test voltage > 4V ,< 8V > 4V ,< 8V
Short circuit current > 200 mA > 200 mA

Battery life: Insulation Test: > 1000 tests Weight: 0.55 kg


Size (HxWxD): One Year Warranty
203 mm x 100 mm x 50 mm

Fluke 1503/1507 Applications


Included Accessories
TP165x Remote Test Probe
TL224 SureGrip Silicone Test Lead Set
TP74 Lantern Tip Test Probe Set
Alligator clips

Ordering Information
Fluke 1503 Insulation Tester Insulation test at a Wiring test in a small
Fluke 1507 Insulation Tester distribution panel distribution box –
all in one spot

Recommended Accessories

C101 PAK TLK 225 AC285 L210


See page 119 See page 120 See page 111 See page 110 See page 121
38
1577/1587
Insulation Multimeters

Two powerful tools in one


The Fluke 1587 and 1577 Insulation Whether you work on motors, generators,
Multimeters combine a digital insulation cables, or switch-gear, the
tester with a full-featured True RMS Fluke 1587/1577 Insulation Multimeters
digital multimeter in a single compact, are ideally suited to help you with your
handheld unit, which provides maximum tasks.
versatility for both troubleshooting and
preventive maintenance. The Fluke 1587T is specially designed for
the telecom environment.

Features
Multimeter Features 1577 1587 1587T
True RMS Voltage and Current for accurate measurements O O O
Digital display counts 6000 6000 6000
Autorange and manual range for easy testing. O O O
Selectable filter for accurate voltage and frequency measurements on motor O O
drives
Min Max Recording, Diode test, temperature, capacitance & frequency O O
measurement for maximum flexibility.
Fluke 1577
Insulation features
User selectable test voltages for many applications O O
Additional test voltages 50V, 100V, 250V O
Special remote control probe for easy and safe measurements O O O
Auto-discharge of capacitive voltage for added user protection O O O
Live circuit detection prevents insulation test if voltage > 30V is detected for O O O
added user protection

General features
Auto Power off to save batteries O O O
Large display with backlight O O O
Fluke 1587 Input Alert to warn for incorrect connections O O O
Fluke 1587T
Continuity O O O

Insulation Specifications
Functions 1577 1587 1587T
Measurement range 0.1MΩ to 600MΩ 0.01MΩ to 2GΩ 0.01MΩ to 100MΩ
Test voltages 500V, 1000V 50V, 100V, 250V, 500V, 50V, 100V
1000V
Test voltage accuracy + 20%, -0% + 20%, -0% + 20%, -0 %
Insulation test current 1mA nominal 1 mA nominal 1 mA nominal
Auto discharge Discharge time < 0.5s Discharge time <0.5s Discharge time <0.5s
for C = 1 μF or less for C = 1 μF or less for C = 1 μF or less
Maximum capacitive load Up to 1 μF load Up to 1 μF load Up to 1 μF load

Multimeter Specifications
Functions Maximum Max. resolution 1577 1587/1587T
Voltage DC 1000V 1 mV ± (0.2% + 2) ± (0.09% + 2)
Voltage AC 1000V 0.1mV ± (2% + 3) ± (2% + 3)
Current DC 400mA 0.01mA ± (1.0% + 2) ± (0.2% + 2)
Current AC 400mA 0.01mA ± (2% + 2) ± (1.5% + 2)
Resistance 50.0MΩ 0.1Ω ± (1.2% + 2) ± (0.9% + 2)
Capacitance 9999μF 1 nF - ± (1.2% + 2)
Frequency 99.99kHz 0.01 Hz - ± (0.1% + 1)
Temperature -40°C to +537°C 0.1°C - ± (1% + 10)
Included Accessories
C101 Rugged, utility hard case Battery life: Meter: 1000 hrs, Weight: 0.55 kg
TL224 SureGrip Silicone Test Lead Set Insulation Test: >1000 tests Three Year Warranty
AC285 SureGrip Alligator Clip Set Size (HxWxD):
203 mm x 100 mm x 50 mm
80BK Integrated DMM Temperature Probe
(Type K) Recommended Accessories
TP165X Remote Test Probe

Ordering Information
Fluke 1577 Insulation Multimeter
Fluke 1587 Insulation Multimeter
Fluke 1587T Insulation Multimeter C25 i400 TPAK L215 TL238
See page 118 See page 114 See page 120 See page 111 See page 110
(for Telecom)
37
1550B MegOhmMeter

Digital insulation testing up to 5000 Volts


The Fluke 1550B is a digital insulation • Guard system eliminates the effect
tester capable of testing switchgear, of surface leakage current on high-
motors, generators and cables at up to resistance measurements
5000 V DC. It can be used for a wide range • Large digital/analog LCD shows detailed
of tests: from simple spot checks to timed measurement data
tests and breakdown tests. Measurement • Cable or insulation capacitance
storage and PC interface software make it • Leakage current
ideal for preventive maintenance. • Ramp function (0-5000 V DC) for
breakdown testing
• Test voltages of 250 V, 500 V, 1000 V, • Timer 1 to 99 minutes
2500 V, 5000 V • Polarization index and dielectric
• Capable of testing in 50 V increments absorption calculated automatically
between 250 V and 1000 V, and 100 V • 99 memory locations store all
increments between 1000 V and 5000 V measurements parameters
• Measures 0 to 1 Tera-Ohm • Includes Quicklink 1550B Software and
• Warning voltage function alerts the Optical Interface cable
user that line voltage is present and
gives the voltage reading up to 600 V
AC or DC

Fluke 1550B

Specifications
Test Voltage (DC) Range Accuracy (+/- reading)
250V 200kΩ to 5GΩ 5%
5GΩ to 50GΩ 20%
500V 200kΩ to 10GΩ 5%
10GΩ to 100GΩ 20%
1000V 200kΩ to 20GΩ 5%
20GΩ to 200GΩ 20%
2500V 200kΩ to 50GΩ 5%
50GΩ to 500GΩ 20%
5000V 200kΩ to 100GΩ 5%
100GΩ to 1TΩ 20%
Short circuit current greater than 1 mA and less than
2mA
Bar graph range 0 to 1TΩ
Insulation test voltage accuracy 0% to + 10% at 1mA load current
Induced AC mains current rejection 2 mA maximum
Charging rate for capacitive load 5 seconds per μF

Leakage current 1nA to 2mA ± (5% + 2nA)


Capacitance measurements 0.01μF to 15.00μF ± (15% rdg + 0.03μF)
Live circuit indicator 30V to 600V AC/DC, 50/60Hz ± (5% + 2V)
Timer increments; indicated to within 1 second 1 to 99 minutes; settable in
1 minute
Ramp 0% to 100% of selected test
voltage, or until breakdown.

Included Accessories
Test leads, 5000 V-rated probes, Alligator clips,
Interface cable
Flukeview Forms Basic, soft carrying case with Operating Temperature: -20°C to 50°C Batteries: 12 volt, lead-acid, rechargeable
water-proof bottom, instruction manual Storage Temperature: -20°C to 65°C Size (HxWxD): 170 mm x 242 mm x 330 mm
Relative humidity: 80% at 31°C, Weight: 4 kg (with battery)
50% at 50°C Two Year Warranty
Ordering Information Dust/water resistance: IP40
Fluke 1550B MegOhmMeter Operating Altitude: 0 to 2,000 mtrs.

FVF-SC2
See page 120
39
1620 Series
Earth Ground Testers GEO

Advanced technology for all your earth


ground testing applications
The new Fluke 1620 Series Earth Ground Earth ground resistance and soil
Testers not only measure ground resistivity should be measured
resistance using the classic ‘fall of when:
potential test’ but also enable time • Designing earth ground systems
saving testing using the ‘selective’ and • Installing new ground system and
‘stakeless’ methods. ‘Selective’ testing electrical equipment
does not require the electrode under • Periodically testing ground and
test to be disconnected during the lightning protection systems
measurement, thus increasing safety. • Installing large electrical equipment
The simple ‘stakeless’ method quickly such as transformers, switchgears,
Fluke 1623 checks ground connections using two machines, etc.
current transformers (probes) clamped
around the ground conductor under test.
Offering ‘one-button’ simplicity, the 1623
is an all-in-one earth ground tester, while
the 1625 has extra versatility for more
demanding applications.

Features
1623 1625
One-button measurement concept O
3- and 4-pole earth ground measurement O O
4-Pole soil resistivity testing O O
2-Pole resistance measurement AC O O
Fluke 1625
2-and 4-pole resistance measurement DC O
Selective testing, no disconnection of ground conductor (1 clamp) O O
Stakeless testing, quick ground loop testing (2 clamps) O O
Measuring frequency 128 Hz O
Earth impedance measurement at 55 Hz O
Automatic frequency control (AFC) (94 – 128 Hz) O
Measuring voltage switchable 20/48V O
Programmable limits, settings O
Continuity with buzzer O
Dust/water resistance IP56 IP56
Safety rating CAT II 300 V CAT II 300 V

Specifications
(Check the Fluke web for detailed specifications)

1623 1625
Fluke 1625 kit
Resistance ranges 0 to 20 kΩ 0 to 300 kΩ
Operating error ± 5% ± 5%
Included accessories Test voltage 48 V 20 / 48 V
Fluke 1623: Protective holster, 2 test leads, Short circuit current > 50mA 250 mA
2 alligator clips, users manual
Fluke 1623 Kit: same as above plus stake/reel
Set 4 pole and selective/stakeless clamp set Battery type: 6 x AA alkaline cells
Fluke 1625: Protective holster, 2 test leads, Size (HxWxD): 110 mm x 180 mm x 240 mm
Weight – 1623 Geo: 1.1 kg (including batteries)
2 alligator clips, users manual
1625 Geo: 1.1 kg (including batteries)
Fluke 1625 Kit: same as above plus stake/reel Two Year Warranty
set 4 pole and selective/stakeless clamp set

Ordering information Recommended Accessories


Fluke 1623 Basic GEO Earth Ground
Tester
Fluke 1623 Kit Basic GEO Earth Ground
Tester Kit
Fluke 1625 Advanced GEO Earth
Ground Tester
Fluke 1625 Kit Advanced GEO Earth
Ground Tester Kit EI-1623 EI-1625 ES-162P3 ES-162P4 EI-162BN
Selective/stakeless clamp Selective/stakeless clamp Stake/reel set for 3 pole Stake/reel set for 4 pole 320mm Split core
set for 1623 set for 1625 measurements measurements transformer for selective
40 measurements on high
voltage pylons
1621 Earth Ground Tester

Handheld earth ground testing


for mobile use
The Fluke 1621 is an easy-to-use Features
earth ground tester. The first line of • 3-pole Fall-of-Potential earth testing for
defense in detecting reliable ground basic measurements
connections, the unit features basic • 2-pole resistance measurements for
ground testing methods including 3-pole added versatility
Fall-of-Potential as well as 2-pole ground • Easily capture values with single-button
resistance. Its convenient size, rugged operation
holster, and large, clear LCD display make • Ensure accurate measurements with
it an ideal field earth tester, for most automatic ‘noise’ voltage detection
work environments. With a simple user • Hazardous voltage warning offers
interface and intuitive functionality, the increased user protection
Fluke 1621 is a handy tool for electrical • Clearly read and record data with a
contractors, utility test engineers, and large, backlit display
earth ground specialists. • Rugged holster and design for tough
work environments
• Portable size allows for easy
transportation
• Instantly be alerted to measurements
outside of your set limit, when you use
the adjustable limit setting
• Safety rating CAT II 600 V

Fluke 1621

Specifications
(Check the Fluke web for detailed specifications)

1621
Resistance range 0.15 Ω to 2 kΩ
Basic accuracy ± 6% of measured value + 5D
Operating error according EN61557 ± 18% of measured value +5D
Test voltage 23 to 24 V AC
Short circuit current > 50 mA AC

Battery type: 1 x 9 V alkaline (LR61)


Size (HxWxD): 216 mm x 113 mm x 54 mm
Weight: 0.850 kg
Two Year Warranty

Recommended Accessories
Included accessories
Two measuring leads with alligator clips -
2 m, protective holster, users manual, CD-ROM

Ordering information
Fluke 1621 Earth Ground Tester
GEO CABLE-REEL 25M GEO CABLE-REEL 50M GEO EARTH STAKE ES-162P3
Ground Earth Cable Reel Ground Earth Cable Reel Ground Earth Stake Stake/reel set for 3 pole
25 M Wire 50 M Wire measurements
41
1630 Earth Ground
Clamp Meter

Fast and easy earth ground loop testing


The Fluke 1630 earth ground clamp • Rapid evaluation of continuity without
meter simplifies ground loop testing and disconnection and audible HI/LO alarm
enables non-intrusive leakage current • Display-HOLD function to freeze
measurement. The ground loop testing is measurements
also known as “stakeless” earth ground • Recording function for automatic
testing. To carry out the measurement storage of measured values, which can
there is no need for placing earth stakes be recalled later on the LCD display
and disconnecting the earth system • Automatic self calibration ensures
from the electrical installation. The Fluke correct measurement every time
1630 combines the two current clamps
needed to perform the stakeless ground The Fluke 1630 is ideally suited for the
loop test in one compact and easy to use following applications:
instrument. • Ground loop checks on any earthing
• Ground loop resistance testing without system
any disconnection or additional earth • Continuity tests on earth bonding
stakes circuits and connections
• Earth ground leakage current • Inspection of lightning protection
measurement for system systems
troubleshooting • Leakage current measurement for
• True RMS AC current measurement troubleshooting on earth ground
range up to 30 A systems

Specifications
(Check the Fluke web for detailed specifications)

Range Max. resolution


Resistance 0.025 to 1500 Ω 0.002 Ω
Fluke 1630 Cntinuity buzzer < app. 40 Ω
Leakage current 0.2 to 1000 mA 0.001 mA
Current 0.2 to 30 A 0.01 A

Weight: 0.64 kg
Conductor Size: 35 mm approx.
Size (HxWxD): 257 mm x 100 mm x 47 mm
Battery type: 9 V IEC 6 LR 61
Two Year Warranty

Ground resistance measurements principle


Ground resistance measurements principle

Rg R1 R2 R3 .....Rn

Equivalent circuit diagram

Included Accessories
Rugged carrying case with belt, Resistance test R1 R2 .....Rn
loop, 9 V battery, Operating instructions.

Ordering Information
Fluke 1630 Earth Ground Clamp Meter Rg

Rg

42
Installation Testers/
Portable Appliance Testers

Our multifunction testers have redefined the standards for ease-of-use.


Designed for ensuring fixed wiring is installed according to IEC 60364,
they perform all tests required to verify safety. Our Portable Appliance
Testers verify the safety and operation of portable appliances, and are
designed for ‘one-touch’ operation and a fast throughput.

43
1650B Series Multifunction
Installation Testers

Extra functionality, faster testing,


and as rugged as ever
Safer, easier installation testing. The especially contractors, everyone who
new 1650B Series builds on the rugged would want to have the best tool
reputation of the earlier 1650 Series, available and always understands (or
only it’s re-designed to meet your need know) how to use.
for more productive test tools. With
new features like the fast, high current 1652B - The ideal tester for
loop test (including a non-trip test) professional trouble-shooters
Fluke 1653B
and a variable RCD trip current setting, This is the instrument that is indeed
accuracy is even better and the test ideal for professional users due to its
cycle even faster. And with the addition additional functionality. It is also ideal
of a unique zero adapter accessory for since even though it has high-end
accurate mains test lead compensation, features, it is still easy to use – even
the 1650B Series continues to set the after longer periods of non-use; because
standard in installation testers. The operating it is intuitive and not forgotten
1650B Series testers verify the safety easily.
of electrical installations in domestic,
commercial and industrial applications. 1651B - The everyday tester, for
They can ensure that fixed wiring is
every electrical installer
Fluke 1652B safe and correctly installed to meet the
This is the instrument that can be
requirements of IEC 60364, HD 384 and
used every single day (day in, day out),
BS 7671 17th Edition wiring regulations.
and covers all the basic needs. It is the
preferred tester for every front-line
1653B - The complete tester for electrician/installer.
advanced users
This is the instrument that has it all, in
a word: it’s complete. From all the test
functions you need to in-built memory
for documenting results. This makes it
Fluke 1651B the complete solution for professionals,
Features
1653B 1652B 1651B
Zero adapter O O O
Volts (V) O O O
Frequency (Hz) O O O
Insulation (RISO) O O O
Continuity (RLO) O O O
Fast high current loop test (ZI) O O O
Loop test non trip mode (ZI) O O O
BS7671 17th Edition IEE Wiring Short Circuit Current (PSC,PEFC, IK) O O O
Regulations IEC 60364.6.61, HD 384 RCD FI Trip TimeTest (FI, DDR) O O O
Variable RCD current setting O O O
Tests time-delayed RCD´s (S-type) O O O
RCD Ramp Test (FI, DDR) O O
Included Accessories RCD Auto Test (FI, DDR) O O
6 AA Cell batteries
Test of pulse sensitive RCD´s O O
C1600 Hard carrying case Earth Resistance (RE) O
Zero Adapter Phase Sequence O
Mains test cord Internal Memory O
TL165X STD Standard Test Lead Set IR Interface for downloading data O
TL165/UK Fused Test Lead Set (UK only) Remote probe O O O*
Padded carrying strap * Not in the UK
Quick reference guide
TP165X Remote control probe and lead 1
Users manual on CD-ROM

1 In the United Kingdom and Ireland: 1652B & 1653B only

Ordering Information
Fluke 1651B Multifunction Installation Tester
Fluke 1652B Multifunction Installation Tester
Fluke 1653B Multifunction Installation Tester Recommended Accessories
See also page 48 for more details
Check the Fluke website for the various
software modules

TLK290 MTC1363 (UK) MTC77 (Europe) ES165X (1653) FVF-SC2 (1653)


Test Probe Kit Mains Test Cord Mains Test Cord Earth Spike Test Kit See page 120
44
1650B Series Multifunction
Installation Testers

Extra functionality, faster testing,


and as rugged as ever

Specifications
(Check the Fluke web for detailed specifications)
AC Voltage Measurement
Range Resolution Accuracy Input Impedance Overload Protection
50 Hz – 60 Hz
500 V 0.1 V ± (0.8% + 3 digits) 3.3 MΩ 660 Vrms

Continuity Testing
Range Resolution Test Current Open Circuit Voltage Accuracy
(autoranging)
20 Ω 0.01 Ω
200 Ω 0.1 Ω > 200 mA > 4V ± (1.5%+3 digits)
2000 Ω 1Ω

Insulation Resistance Measurement


Slim probe design Model Test Voltage Insulation Resolution Test Current Accuracy
Thanks to its slim probe with integral test button, Resistance Range
you can safely make one-handed measurements 1653B 50 V 10 kΩ to 50 MΩ 0.01 MΩ 1 mA @ 50 kΩ ± (3%+ 3 digits)
on hard to reach points, while keeping your eyes 1653B 100 V 20 MΩ to 100 MΩ 0.01 MΩ 1 mA @ 100 kΩ ± (3%+ 3 digits)
0.1 MΩ
on the panel. This remote probe is powered by 1653B 250 V 20 MΩ to 200 MΩ 0.01 MΩ 1 mA @ 250 kΩ ± (1.5%+ 3 digits)
the tester so always operable (does not require 1652B 0.1 MΩ
additional batteries!). 1651B
1653B 500 V 20 MΩ 0.01 MΩ 1 mA @ 500 kΩ ± (1.5%+ 3 digits)
1652B 200 MΩ 0.1 MΩ + 10%
1651B 500 MΩ 1 MΩ
1653B 1000 V 20 MΩ 0.1 MΩ 1 mA @ 1 MΩ ± (1.5%+ 3 digits)
1652B 200 MΩ 1 MΩ + 10%
1651B 1000 MΩ
Loop Impedance Measurement
Range Resolution Accuracy
20 Ω 0.01 Ω No trip mode: ± (3% + 6 digits)
200 Ω 0.1 Ω Hi current mode: ± (2% + 4 digits)
2000 Ω 1Ω
PFC. PSC Test
Range 1000A / 10kA(50kA)
Resolution and Units 1A / 0.1kA
Accuracy Determined by accuracy of loop resistance and mains
voltage measurements
Computation
Prospective Earth Fault Current (PEFC) or Prospective Short Circuit Current (PSC) determined by dividing
measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.
Zero Adapter RCD Testing
For easy, always reliable and accurate RCD Type 1651B 1652B 1653B
compensation for test leads and mains cords. 1
AC 2G O O O
This adapter can be used for all different kind AC 3S O O O
of mains plugs as well as test accessories like 4
A G O O
probes, alligator clips etc. A S O O
1
AC – responds to AC 2G – General, no delay 3S – Time delay 4
A - Responds to pulsed signal
Tripping Time Test (ΔT)
Current Settings Multiplier Test Current Accuracy Trip Time Accuracy
10, 30, 100, 300, 500, 1000 mA, VAR x 1/2 + 0% - 10% ± (1% Reading + 1 digit)
10, 30, 100 mA X5 + 10% - 0% ± (1% Reading + 1 digit)

Tripping Current (Ramp) Test – Fluke 1653B and 1652B only


Current Range Step size Dwell time Trip Current
50% to 110% of 10% of I Δ N Type G Type S Measurement Accuracy
RCD’s rated current 300 ms/step 500 ms/step ± 5%

Earth Resistance Test (RE) – Fluke 1653B only


Range Resolution Accuracy
200 Ω 0.1 Ω ± (2% + 5 digits)
2000 Ω 1Ω ± (3.5% + 10 digits)

Battery type: Alkaline supplied. usable Weight: 1.17 kg


Complete kit with 1.2 V NiCD or NiMH rechargeable Three Years Warranty
All 1650B models are equipped with detachable batteries
leads that can be replaced in case of damage Size (HxWxD):
or loss. A durable hard case will protect your 100 mm x 250 mm x 125 mm
instrument in tough field conditions.

45
6000 Series PAT Testers

Versatile PAT testing at your fingertips


The Fluke 6200 and 6500 PAT testers Fluke simplifies portable
verify the electrical safety and operation appliance testing
of portable appliances in accordance • Compact and lightweight…
with relevant guidelines and regulations. Efficient to work with and easy to carry
With powerful auto test capabilities and around– and has extra space in the
simplified controls they increase the hard case for accessories.
number of tests you can perform per day • One touch simplicity…
without compromizing results. Pre-set and user-definable test routines
are initiated from a single button – to
A choice of automatic and manual speed up test procedures and save you
Fluke 6200 PAT testers time on site.
Both models perform all the tests • A better way of working…
required for class I and class II Rapid data entry via a QWERTY
appliances. For manual testing and low keyboard (or optional Fluke barcode
volume applications, choose the cost- scanner) and fast data transfer from
effective 6200 PAT model. If you need a the main memory or the Compact Flash
more powerful instrument to test large memory card (6500).
numbers of appliances, the 6500 is the
right choice.

6200 6500
• Dedicated key for each test for ‘one- As 6200 but also with:
touch’ testing • Integral QWERTY keyboard for rapid
• Pre-set pass/fail levels to save time data entry
Fluke 6500 • Large backlit display for easy reading • Slot for Compact Flash memory card for
back-up data storage and transfer to PC
• Pre-set, auto-test sequences for user
Also available with European mains socket. convenience

Features
Measurement functions 6200 6500
L N Mains Volts O O
Outside Limits Indicators O O
Null out facility for earth bond lead O O
Protective Earth Resistance PE (200mA) O O
Protective Earth Resistance PE (25A) O O
Insulation 500V dc O O
Protective Earth Conductor Current O O
Touch Current O O
Substitute Leakage Current O O
Appliance Power kVA O O
Appliance Load Current O O
Seven Segment Custom LCD O
Included Accessories Graphical LCD O
Test lead, Test probe, Crocodile clip, Back Light O O
Mains cord Compact Flash Card receptacle O
Serial Port - Printing / Downloading O O

Ordering Information External printer output O O


Fluke 6200 PAT Tester Front Panel QWERTY Key pad O
Fluke 6500 PAT Tester
IEC Lead Test O O
Not available in all countries Auto-testing O
Pass / Fail Level Programmable Indicators O
Data Storage O
Limited Data Storage O
Polarity Checks O O
Graphical Help Menu On Line O
Programme Mode O
Real time clock O

Front panel results management O


230V BS1363 Test socket / 230V Mains BS1363 input power plug O O

46
6000 Series PAT Testers

Specifications

The accuracy specification for the display range is defined as ± (%reading + digit counts) at 23 °C ± 5 °C, ≤ 75 %
RH. Between 0 °C and 18 °C and between 28 °C and 40 °C, accuracy specifications may degrade by 0.1 x (accuracy
specification) per °C. The measurement range meets the service operating errors specified in EN61557-1: 1997,
EN61557-2: 1997 , EN61557-4: 1997.

Separate hard case Power-on Test Touch Current Test


The compact Fluke PAT testers are supplied with a The test indicates reversed L-N, missing PE, and Display Range 0 to 1.99 mA ac
measures the mains voltage and frequency.
hard carrying case that not only offers protection Display Range 90 V to 264 V
Accuracy ± (4% + 2 counts)

during transit but also includes extra storage space for Accuracy at 50 Hz ± (2% + 3 counts)
Resolution 0.01 mA

accessories and other tools. They’re extremely light, Resolution 0.1V (1V - model 6200)
Internal Resistance (via probe) 2 kΩ
Measuring method Probe
weighing approximately 3 kg (without case) and have Input Impedance > 1 MΩ // 2.2 μF
The appliance under test is energized at mains potential.
integral carrying handles for extra convenience. Maximum Input Mains Voltage 300 V

Substitute Leakage Current Test


Earth Bond Test Display Range 0 to 19.99 mA ac
Display Range 0 to 19.99 Ω Accuracy ± (5% + 5 counts)
Accuracy ± (5% +4 counts) Resolution 0.01 mA
(after Bond Test zeroing)
Test Voltage 35 V AC ± 20%
Resolution 0.01Ω
Operational Error 10%
Test Current 200 mA AC - 0% + 40% into
1.99Ω
25 A AC ± 20% into 25 mΩ Load/Leakage Test: Load Current
at 230 V
Display Range 0 to 13 A
Open Circuit Voltage > 4 V AC, < 24 Vac
Accuracy ± (4% + 2 counts)
Bond Test zeroing can subtract up to 1.99Ω
Resolution 0.1 A
The appliance under test is energized at mains potential

Insulation Test (Riso) Load/Leakage Test: Load Power


Special PAT Kit Display Range 0 to 299 MΩ Display Range 0 to 999 VA
If you need a complete PAT tester solution, Accuracy ± (5% + 2 counts) from 0.1
1.0 kVA to 3.2 kVA
Accuracy ± (5% + 3 counts)
a purpose made kit is available. to 50 MΩ
± (10% + 2 counts) from 50 Resolution 1 VA (0 to 999 VA)
Fluke 6500/UK Kit Contains: to 299 MΩ 0.1 kVA (1.0 kVA to 3.2 kVA)
• 6500, Mainframe Resolution 0.01 MΩ (0 to 19.99 MΩ) The appliance under test is energized at mains potential
0.1 MΩ (20 to 199,9 MΩ)
• EXTL 100, Extension lead test adaptor 1 MΩ (200 to 299 MΩ)
• SP Scan 15, Barcode scanner Test Voltage 500 V DC - 0% + 25% at
500 kΩ load Load/Leakage Test: Leakage Current
• Fluke PowerPat Plus Test Current > 1 mA at 500 kΩ load,
Display Range 0.25 to 19.99 mA
• Pass 560R, Appliance pass labels < 15 mA at 0 Ω
Accuracy ± (4% + 4 counts)
• Fail 100S, Appliance fail labels APP 1000, Auto discharge time < 0.5 s for 1 μF
Max. Capacitive Load Operational up to 1 μF Resolution 0.01 mA
Barcode appliance number labels The appliance under test is energized at mains potential

(Kit contents may vary per country) PELV Test


Accuracy at 50 Hz ± (2% + 3 counts)
Overload protection 300 Vrms
Warning threshold 25 Vrms

Display Screens
Size (HxWxD): 200 mm x 275 mm x 100 mm
Weight: 3 kg
Two Years Warranty

Substitute Leakage Earth Bond Test (RPE)


Current Test

Recommended Accessories
See also page 48 for more details

Fluke PowerPat Plus SP1000-02 SP-SCAN-15 BDST3 Snap Tags PASS


Insulation Test (RISO) Touch Current Test software Mini printer Barcode scanner Cable Tie Appliance 560R
(6500 Fluke only) Pass Labels
47
1650B Series/6000 Series
Accessories

Accessories for Fluke 1650B Accessories for Fluke 6500 Series Portable
Series Installation Testers Appliance Testers

PASS560R Appliance Pass Labels


Quantity 500
ES165X Earth Spike Test Kit SP1000 Mini Printer
(Fluke 1653B) Without using any additional software the
Earth Spike Test kit contents: SP1000 can be used to directly printout stored
• Auxiliary earth probes test records on to thermal paper. The printer
• Test connection leads and crocodile clips is compact and easily transported and is ideal
• Purpose-made carry case for test professionals who need to issue an
immediate written account of work carried
out. The printer is powered by a rechargeable
battery and comes complete with mains
charger and RS232 Printer Lead.
SP1000 Paper
APP1000/APP2000 Bar Code Appliance Replacement thermal paper for the SP1000
Number Labels Mini Printer
APP1000: Labels numbered 0001-1000
APP2000: Labels numbers 1001-2000
Label number >2000 on request

FVF-SC2 Fluke ViewForms Software Fluke DMS software for


(Fluke 1653B) 1650B/6000 Series
To address the increasing demands for
reporting and documentation, Fluke presents
FlukeView Forms documenting software.
Download the data from the Fluke 1653B and
create an easy report. The Fluke ViewForms
Software also supports other Fluke tools. See BDST3/BDST4 Snap Tags
page 120. BDST3: Cable Tie
BDST4: Clip On
Quantity 20. Without labels.

The Fluke DMS (Data Management Software)


is an efficient program for administration and
reporting of installation tests in compliance
with EN 60364, DIN VDE 0100/0105, BS7671
17th edition wiring resulation and appliance
TLK 290 Test Probe Kit
tests in compliance with DIN VDE 0701/0702,
• Kit includes three flexible socket probes and EXTL100-02 (UK plug) EXTL100-02 (Schuko plug) ÖVE E 8701.
a large alligator clip
• To be used on three phase sockets EXTL100 Extension Lead Test Adaptor
• Probes have flexible width test points that fit DMS 0100/INST Software for
Adaptor for testing extension leads. Allows
securely in 4 to 8 mm sockets Installation Tester Fluke 1653B
the earth test lead to be connected to the
• CAT III 1000 V, 8 A Supporting reports for Austria, Germany, UK,
extension leads to perform insulation and
Switzerland, Netherlands
earth bond tests.
DMS 0702/PAT Software for Portable
Appliance Tester Fluke 6500
Supporting reports for Austria, Germany, UK,
Netherlands
DMS COMPL PROF Software for the
Fluke 1653B and Fluke 6500
Supporting reports for Austria, Germany, UK,
Switzerland, Netherlands
MTC1363 MTC77
SPScan15 Barcode Scanner
Check the Fluke web for more information.
Mains Test Cord for 1650B series Easy to use, low current, intelligent barcode
MTC1363 UK plug reader. SPScan15 can be used to scan barcodes
MTC77 Schuko plug attached to curved surfaces or where actual
contact with the barcode surface is difficult.

48
Digital Thermometers

For troubleshooting systems where temperature is a critical symptom,


our digital thermometers provide you with laboratory accuracy wherever
you need it. We offer a choice of non-contact, laser-guided infrared
thermometers for safely getting at hard-to-reach, electrically live or
particularly hot targets, and contact thermometers with a full range of
thermocouple probes.

49
50
Infrared Thermometer Fluke 60 Series Fluke 560 Series Fluke 570 Series
Selection Guide Fluke 61 Fluke 62 Fluke 63 Fluke 66 Fluke 68 Fluke 561 Fluke 566 Fluke 568 Fluke 572 Fluke 574
Temperature range -18 to 275 ºC -30 to 500 ºC - 32 to 535 ºC - 32 to 600 ºC - 32 to 760 ºC - 40 to 550 ºC - 40 to 650 ºC - 40 to 800 ºC - 30 to 900 ºC - 30 to 900 ºC
Accuracy 2% 1.5% 1% 1% 1% 1% 1% 1% 0.75% 0.75%
Response time < 500 mSec < 500 mSec < 500 mSec < 500 mSec < 500 mSec < 500 mSec < 500 mSec < 500 mSec < 250 mSec < 250 mSec
Optical resolution 8:1 10:1 12:1 30:1 50:1 12:1 30:1 50:1 60:1 (50:1 60:1 (50:1
with close with close
focus) focus)
Close focus model O O
available
Recommended distance Up to 2 m Up to 2 m Up to 2.5 m Up to 4.5 m Up to 7.5 m Up to 2.5 m Up to 4.5 m Up to 7.5 m 300 mm 300 mm
to spot (with close (with close
focus) up to focus) up to
10.5 m 10.5 m
Laser sighting single-point single-point single-poimt single-point single-point single-point single-point single-point 3-point 3-point
laser laser laser laser laser laser laser laser laser laser
Adjustable emissivity O O O O O O O
MIN/MAX readings -/O -/O O O O O O O O
AVG readings O O O O O
DIF readings O O O O O O
Backlit LCD O O O O O O O O O O
Bar graph display O O
Audible Hi/Lo alarm O O O O O/- O
Visible Hi/Lo alarm O O O O O/- O
Includes contact probe O O O O
Probe input (types) Type K Type K Type K Type K
RTD RTD
Thermocouple Thermocouple Thermocouple Thermocouple
Data logging (number of
12 points 12 points 20 points 99 points 100 points
measurements)
PC interface USB RS232
Compatible with
FlukeView Forms O O
software

See catalog page 52 52 52 52 52 54 53 53 51 51

Recommended Applications
Selection Guide
Infrared Thermometer

Contact thermometers Plant/facilities maintenance Heating/ventilation/air conditioning/ Manufacturing processes Safety and protection
For our complete range of contact Preventive and predictive maintenance refrigeration Molding temperature measurement Fire localization
thermometers, see page 55. Energy audits Leaky ductwork Printing, paper and converting Hazardous materials
Vehicle and fleet maintenance Thermostats Thermoforming plastics Faulty ballasts
programs Temperature balancing Electronics Search and rescue
Faulty electrical/circuit connections Steam distribution systems Paint curing/drying Smoldering embers
Petrochemical/hazardous locations Compressor lines Food Equipment maintenance
Motors, pumps and bearings Chemical and pharmaceutical
570 Series
Precision Infrared Thermometers

Measure temperature with ease and


precision
The Fluke 570 series are the most • Enhanced optics allows measurements
advanced IR non-contact thermometers, of smaller objects from farther away
and are ideal for predictive and • True Dimension™ three-dot laser
preventative maintenance applications. sighting system highlights the true
Offering a broad temperature range diameter of measurement spots at all
and a true dimension laser sighting distances
system for precise targeting resulting • Adjustable emissivity setting and 30
in more accurate measurements. When pre-set common material values for
requiring analysis and documentation more accurate measurements
use the 100-point data logging and • 100 data point memory for storage of
software for graphing and analysis. measurements (Fluke 574).
From close-up electrical connections, to
far-distance room balancing checks, the
Fluke 570 series can take IR temperature
measurements with ease and precision.

Fluke 574

Features
572 574
Temperature range -30 to 900ºC
Optical resolution Standard: 60:1
Close focus: 50:1
3 dot laser beam for accurate targeting O O
Adjustable emissivity O O
Bar graph display O O
Backlit LCD display O O
Use selectable ºC or ºF O O
Audible and visible Hi/Lo Alarm O/- O/O
MIN/MAX O O
AVG/DIF readings O
Datalogging (number of measurements) 100
PC interface RS232

Specifications
572 574
Temperature range -30 to 900°C
Response time 250ms (95 % of reading)
Resolution 0.1°C of reading up to 900°C
Fluke 572
Repeatability ±0.5% of reading or ±1°C*
Accuracy: (assumes ambient operating temperature of 23 ºC to 25 ºC ) ±0.75% of reading, ±0.75°C *
Typical distance to target 10,5 m
Emissivity Digitally adjustable from 0.10 to 1.0
by 0.01
Included Accessories *whichever is greater.
Fluke 572: Hard case, 2 batteries
Fluke 574: Hard case, 2 batteries, Thermocouple
K probe, 220V power supply, IRGraph software,
RS232 cable Battery Life: 10 hours typical
Weight: 0.480 kg
Size (HxWxD): 200 mm x 170 mm x 55 mm
Ordering Information Two years warranty
Fluke 572 Precision Infrared Thermometer
Fluke 574 Precision Infrared Thermometer
Fluke 572CF Precision Infrared Thermometer
with close focus option Recommended Accessories
Fluke 574CF Precision Infrared Thermometer
with close focus option

AN5 C570
Analog data cable See page 118
51
60 Series
Infrared Thermometers

Point, press and read temperature


The Fluke 60 Series non-contact The 60 Series IR thermometers
thermometers are the ideal professional feature:
diagnostic tools for quick and accurate • Laser guided sighting system for easy
temperature measurements. targeting with 1% accuracy
These handheld tools are ideal for • Up to 12 points datalogging with Min/
measuring surface temperatures of Max/Average functions
rotating, hard-to-reach, electricity live • Up to 50:1 optical resolution
or dangerously hot targets like electrical • Choice between models with fixed or
motors and – panels, and heating and adjustable emissivity
ventilation systems. • Backlit display for easy reading in the
Fluke 68 The laser sighting system guides dark
measurements to the right target and in • Temperatures up to 760°C
less than a second, the large temperature
display provides a readout of the surface
temperature.
Fluke 66
Features
61 62 63 66 68
Form factor Flat grip Pistol grip Pistol grip Pistol grip Pistol grip
Fluke 63 Temperature range -18 to 275°C -30 to 500 °C -32 to 535°C -32 to 600°C -32 to 760°C
Optical resolution 8:1 10:1 12:1 30:1 50:1
Fluke 62
Laser beam for accurate targeting O O O O O
Backlit LCD display O O O O O
Use selectable °C or °F O O O O O
Min/max/avg/dif readings Max Max O O
Datalogging O O
Hi/Lo Alarm O O
Adjustable emissivity O O

Specifications
61 62 63 66 68
Range - 18 to 275ºC - 30 to 275 ºC - 32 to 535 ºC - 32 to 600 ºC - 32 to 760 ºC
Response time < 500ms < 500ms ≤ 0.5 second ≤ 0.5 second ≤ 0.5 second
(95 % of reading)
Resolution 0.2 ºC 0.2 ºC 0.2 ºC 0.1 ºC 0.1 ºC

Repeatability ± 2% ± 0.5% ± 0.5% ± 0.5% ± 0.5%


Fluke 61 (% of reading) or ± 2 ºC* or < ± 1 ºC* or ≤ ± 1 ºC* or ≤ ± 1 ºC* or ≤ ± 1 ºC*
Accuracy: For targets at: For targets at: For targets at: For targets at: For targets at:
(assumes ambient -18 to -1ºC: ± 3ºC 10 °C to 30 °C: ±1 °C -32 to -26°C: ± 3°C -32 to -26°C: ± 3°C -32 to -26°C: ± 3°C
operating temperature -1 to 275ºC: ± 2% of ± 1.5% of reading -26 to -18°C: ± 2.5°C -26 to -18°C: ± 2.5°C -26 to -18°C: ± 2.5°C
of 23ºC) reading or ± 2ºC or ± 1.5°C whichever -18 to 23°C: ± 2°C -18 to 23°C: ± 2°C -18 to 23°C: ± 2°C
is greater over 23°C -510°C: ± 1% For targets above For targets above
the balance of the range of reading or ± 1°C* 23 ºC: 23 ºC:
For targets ± 1% of reading ± 1% of reading
The Fluke FoodPro™ thermometer above 510°C: or ± 1 ºC* or ± 1 ºC*
± 1.5% of reading
series provide advanced
temperature measurement solutions Typical distance to Up to 1m Up to 1.5 m Up to 2 m 5m 8m
target
for the foodservice industry. Check Emissivity Fixed at 0.95 Pre-set to 0.95 Fixed at 0.95 Digitally adjustable Digitally adjustable
the Fluke web for more information. from 0.1 to 1.0 from 0.1 to 1.0
by 0.01 by 0.01

* whichever is greater

Battery Life: Weight:


Fluke 66 and 68: 20 hours with laser and backlight on 50% Fluke 63, 66 and 68: 0.320 kg
Included Accessories Fluke 63: 10 hours with laser and backlight on Fluke 62: 0.200 kg
Fluke 61: 9V Battery Fluke 62: 12 hours with laser and backlight on Fluke 61: 0.227 kg
Fluke 61: 12 hours with laser and backlight on
Fluke 62: 9V Battery, storage holster Fluke 62: 2 years warranty
Fluke 63, 66 and 68: Hard carrying case, Size (HxWxD): Other models: one year warranty
9V batteries Fluke 63, 66 and 68: 200 mm x 160 mm x 55 mm
Fluke 62: 152 mm x 101 mm x 38 mm
Fluke 61: 184 mm x 45 mm x 38 mm

Ordering information
Fluke 61 Infrared Thermometer
Fluke 62 Mini Infrared Thermometer Kits Recommended Accessories
Fluke 63 Infrared Thermometer
Fluke 66 Infrared Thermometer
Fluke 68 Infrared Thermometer
Fluke 62/322/1AC (see page 5)
Fluke T5-600/62/1AC (see page 5)
C23 80PR-60 H6
See page 118 See page 117 See page 119
52 Fluke 62/322 kit T5-600/62/1AC
566 and 568
Multipurpose Thermometers

The two-in-one infrared and contact thermo-


meter with an innovative graphical display
With a straight-forward, menu-driven • Easily access advanced features with
user interface and graphical display, the soft-key buttons and graphical
the Fluke 566 and 568 multipurpose display
thermometers make even complex • Measure smaller targets from farther
temperature measurements easy. Quickly away using the IR thermometer
navigate and adjust emissivity, start data • Adjustable emissivity and built-in table
logging, or turn on and off alarms, with of common materials for higher IR
just a few pushes of a button. For added accuracy
convenience, both rugged handheld • Quickly identify problems with the MIN,
thermometers combine contact and MAX, AVG, and DIF functions
non-contact temperature measurement • 2-color flashing alarm alerts you
capability, providing a total temperature visually when measurements exceed
measurement solution for any service limits
and maintenance program. • Includes Type K thermocouple bead
probe
• Compatible with all standard mini-
Fluke 566 connector K-type thermocouples
• Data logging with a date/time stamp
• Soft rubber boot for increased
ruggedness
• User interface available in 6 languages

Fluke 568

Choose your language Select the measurement surface See complete measurement details
in seconds
Specifications
(Check the Fluke web for detailed specifications)

566 568
Infrared temperature range -40 °C to 650 °C -40 °C to 800 °C
Infrared accuracy < 0 °C : ± (1.0 °C + 0.1°/1 °C);
> 0 °C : ± 1 % or ± 1.0 °C, whichever is greater
Display resolution 0.1 °C
Infrared spectral response 8 μm to 14 μm
Infrared response time < 500 msec
The Fluke 566 and included accessories Input temperature range -270 °C to 1372 °C
Input accuracy -270 °C to -40 °C: ± (1 °C + 0.2 °/1 °C)
-40 °C to 1372 °C: ± 1 % or 1 °C, whichever is greater
D:S (Distance to measurement spot size) 30:1 50:1
Laser sighting Single-point laser < 1 mw output Class 2 (II) operation, 630 nm to 670 nm
Minimum spot size 19 mm
Emissivity adjustment By built-in table of common materials or digitally adjustable
from 0.10 to 1.00 by 0.01
Data logging with Date/Time stamp 20 points 99 points
PC interface and cable None USB 2.0 with FlukeView®
Forms software
Hi/Low alarms Audible and two-color visual
Min/Max/Avg/Dif Yes
Display Dot matrix 98 x 96 pixels with function menus
Backlight Two levels, normal and extra bright for darker environments
Trigger Lock Yes
Switchable between Celsius and Fahrenheit Yes

The Fluke 568 and included accessories Power: 2 AA/LR6 Batteries (566); 2 AA/LR6 Weight: 0.965 kg (566); 1.026 kg (568)
Batteries and USB for use with a PC (568) Size (HxLxW): 25.4 cm x 19.1 cm x 6.9 cm
Battery life: Used continuously; laser and Operating temperature: 0 °C to 50 °C
backlight on: 12 hours; laser and backlight off: Storage temperature: -20 °C to 60 °C
100 hours Two years warranty
Included accessories
FlukeView® Forms software (568 only), USB
cable (568 only), K-type thermocouple bead
probe, 2 AA batteries, hard carrying case,
quick start guide, and users manual. Recommended Accessories

Ordering information
Fluke 566 Infrared thermometer
Fluke 568 Infrared thermometer

H6 80PK-8 80PK-9 80PK-11 80PK-25 80PK-26


See page 119 See page 116 See page 116 See page 116 See page 116 See page 116
53
561
Multipurpose Thermometer

Combined Infrared and Contact Thermometer


The Fluke 561 combines the temperature • IR thermometer for quick
measurement functions that industrial, measurements up close or at a distance
electrical, and HVAC/R professionals • Single-point laser sighting
need, all in one tool. It measures both • Easy emissivity adjustment for
IR and contact temperature, replacing measuring pipes and ducts more
several other test tools. It’s fast, efficient, accurately
and easy to use, saving you valuable time • Includes a Velcro pipe probe for super-
and effort. With the Fluke 561, you can heat and sub-cooling as well as other
take contact and ambient temperatures surface contact measurements
in the way that’s best for you. Use the IR • Also compatible with all standard mini-
thermometer to measure hot, moving, connector K-type thermocouples
electrically energized, and hard-to- • MIN, MAX and DIF temperature
reach objects instantly. Check motors, readings
insulation, breakers, radiant heating, • Lightweight (only 340 grams) and
pipes, corroded connections, and wires. portable
Plus, scan ducts, and other hard-to-reach • Includes measurement guide
objects from the floor—leave your ladder
in the truck. You can use the Fluke 561’s
Fluke 561 handy Velcro® pipe probe or, plug in any
industry standard, K-type mini-connector
thermocouple probe you already own.

Specifications

Temperature range -40° to 550°C


Display resolution 0.1° of reading
D:S (Distance to spot size) 12:1
Easy emissivity selector Adjustable with three settings: low (0.3), medium (0.7), high (0.95)
Display accuracy (Assumes ambient operating ± 1.0% of reading or ± 1°C, whichever is greater; below 0°C, ± 1°C, ± 1°/1°
temperature of 23° to 25°C)
Response time 500 mSec (95% or reading)
Repeatability ± 0.5% of reading or ± 1°C, whichever is greater
Spectral focus 8 μm to 14 μm
Laser sighting Single-point laser
Laser shutoff Laser turns off above ambient temperature of 40°C
Laser power Class 2 (II) operation; output ‹ 1 mW, wavelength 630 nm to 670 nm
Relative humidity 10% to 90% RH non-condensing, at < 30°C
Power 2 AA batteries (alkaline or NiCD)
The Fluke 561 includes everything you need for Display hold 7 seconds
immediate inspections. Backlit display Yes, LCD with dual temperatures (current and MAX/MIN/DIF/KTC), low battery,
F/C indicator, and Scan/Hold options
Operating temperature 0° to 50°C
Storage temperature -20 to 65°C
MAX, MIN, DIF temperatures Yes
Thermocouple type K mini-adapter input Yes, compatible with industry standard type K probes with mini-connector
Thermocouple type K Velcro pipe probe Yes, with a temperature range of 0° to 100°C and accuracy of ± 2.2°C
Measurement guide Yes

Battery Life (alkaline): 12 hours Weight: 340 grams


Size (HxLxW): 176,9 mm x 163,6 mm x 51,8 mm Two years warranty

Included accessories
Thermocouple K-type Velcro pipe probe,
hand carrying case, 2 AA batteries and user
manual with measurement guide.
Recommended Accessories
Ordering information
Fluke 561 HVACPro Thermometer

H6 80-PK-1 80PK-8 80PK-25


Se page 119 See page 116 See page 116 See page 116
54
50 Series II Thermometers

Laboratory accuracy. Wherever you go.


The Fluke 50 Series II contact Additional features for the 53 and
thermometers offer fast response and 54 Series II:
laboratory accuracy (0.05% + 0.3°C) in • Data Logging up to 500 points of data
a rugged handheld test tool. with user adjustable recording interval
• Real time clock captures the exact time
• Large backlit dual display shows any of day when events occur
combination of T1, T2 (52 and 54 only), • Recall function allows logged data to be
T1-T2 (52 and 54 only) plus MIN, MAX, easily reviewed on the meter display
or AVG • IR communication port allows data to
• Relative time clock on MIN, MAX, and be exported to optional FlukeView®
AVG provides a time reference for major Temperature PC software
events
• Electronic Offset function allows
compensation of thermocouple errors
to maximize overall accuracy
• Readout in °C, °F, or Kelvin (K)
• Sleep mode increases battery life
• Battery door allows easy battery
replacement without breaking the
calibration seal

Features
51 II 52 II 53 II 54 II
Thermocouple types J,K,T,E J,K,T,E J,K,T,E,N,R,S J,K,T,E,N,R,S
Fluke 54 II Number of inputs Single Dual Single Dual
Time stamp Relative Time Relative Time Time of Day Time of Day
Splash/Dust resistant O O O O
Dual display with backlight O O O O
Min/Max/Avg recording O O O O
(T1-T2) True differential O O
Data logging up to 500 points O O
IR data port for interface O O
to PC
Compatible with optional O O
FlukeView Software

Specifications
Fluke 51 II Fluke 52 II Fluke 53 II Temperature range:
J-type Thermocouples -210°C to 1200°C
K-type Thermocouples -200°C to 1372°C
T-type Thermocouples -250°C to 400°C
E-type Thermocouples -150°C to 1000°C
N-type** Thermocouples -200°C to 1300°C
R** and S-type** Thermocouples 0°C to 1767°C
Temperature accuracy
Above –100°C (-148°F):
Included Accessories J, K, T, E, and N-type** ± [ 0.05% + 0.3°C ]
Impact absorbing holster R** and S-type** ± [ 0.05% + 0.4°C ]
Two bead probe thermocouples 80PK-1 (54+52) Below –100°C (-148°F):
One bead probe thermocouple 80PK-1 (51+53) J, K, E, and N-types ± [ 0.20% + 0.3°C ]
T-type ± [ 0.50% + 0.3°C ]

Ordering Information **Only the Fluke Models 53 and 54 Series II thermometers are capable of measuring N, R, and S-type
Fluke 51 II Thermometer
Fluke 52 II Thermometer Battery life: 1000 hours typical, AA Weight: 0.4 kg
Fluke 53 II Thermometer Size (HxWxD): 173 x 86 x 38 mm Three Year Warranty
Fluke 54 II Thermometer
FVF-SC1 FlukeView Forms Software
including interface cable
Recommended Accessories

C25 80PK-26 80PK-25 FVF-SC1 TPAK


See page 118 See page 116 See page 116 See page 120 See page 120
55
1523 and 1524
Reference Thermometers

A new standard in
accuracy and versatility.
Measure, graph and record three High accuracy
sensor types with one tool. The Fluke • PRTs: ±0.011 °C
1523/24 Reference Thermometer deliver • Thermocouples: ±0.24 °C for J,K,L,M
high accuracy, wide measurement • Precision thermistors: ±0.002 °C
range, logging, and trending, all in a
handheld tool you can take anywhere. Fast measurement
For top accuracy, a memory chip inside • PRTs: up to 0.45 seconds/sample
the probe connector feeds probe • Thermocouples: up to 0.3 seconds/
calibration information to the readout. sample
In addition, any thermocouple with • Precision thermistors: up to 0.3
a mini-thermocouple connector can seconds/sample
be read using the optional universal
thermocouple adapter. Choose the 1523 Two models
for single channel or the 1524 for dual • 1523: Single channel standard model;
channel measurement. memory for 25 readings & statistics
• 1524: Two channels; memory for 25
Three sensor types readings and statistics plus logging
• PRTs: –200 °C to 1000 °C 15,000 measurements; real-time clock
• Thermocouples –200 °C to 2315 °C for time and date stamps
Fluke 1524 Fluke 1523 • Precision thermistors: –50 °C to 150 °C

Features
1523 1524
Note: The 1523/24 are pictured with probes connected which may
be purchased seperately. Sensor Types PRT & RTD, Thermistor, and Thermocouple
Thermocouple Types B,C,E,J,K,L,M,N,R,S,T,U
Number of inputs Single Dual
Data trending (graphing) O O
Graphical display with backlight O O
Included Accessories Min/Max/Avg/Standard deviation recording O O
NIST traceable certificate of calibration, users High speed measurement O O
guide, CD-ROM (contains technical manual), RS-232 PC communications O O
12 V dc universal power supply, RS-232 cable, T1-T2 True differential O
9940 I/O ToolKit software Data logging up to 15,000 points O
Time and date stamp O

Ordering Information
Fluke 1523* Reference Thermometer
Fluke 1524* Reference Thermometer
Fluke 1523-P1 Reference Thermometer, Specifications
PRT(–200 °C to 420 °C, 6.35
mm x 298 mm), Universal (Check the Fluke web for detailed specifications)
Thermocouple Adapter, TPAK,
Temperature range
and Case
Thermocouple –200 °C to 2315 °C
Fluke 1524-P1 Reference Thermometer, PRT & RTD –200 °C to 1000 °C
PRT(–200 °C to 420 °C, 6.35 Thermistor –50 °C to 150 °C
mm x 298 mm), Universal Resolution and best accuracy
Thermocouple Adapter, TPAK, Thermocouple 0.01 °, ±0.24 °C
and Case PRT & RTD 0.001 °, ±0.011 °C
Thermistor 0.001 °, ±0.002 °C
* Requires an optional probe Operating temperature –10 °C to 60 °C
Storage temperature –20 °C to 70 °C

Optional Accessories
2384-P INFO-CON Connector, PRT
Battery life (alkaline): 20 hours
(Gray Cap), Spare Power supply: Universal 12 Vdc
2384-T INFO-CON Connector, Size (HxWxD): 200 x 96 x 47 mm
Thermocouple (Blue Cap), Weight: 0.65 kg
Spare Warranty: 1 year
2373-LPRT RTD Adapter, Lemo to
Mini Grabbers (4-wire)

Optional probes: Recommended Accessories


5616-12-P PRT, 6.35 mm x 298 mm,
–200 °C to 420 °C
5615-9-P PRT, 4.76 mm x 229 mm,
–200 °C to 420 °C
5610-9-P Thermistor, 3.2 mm x 229 mm,
0 °C to 100 °C TPAK FLK80P1 FLK80P3 2384P and 2384T 2373-LTC
(80PK1 with universal (80PK-3A with universal Spare INFO-CON Adapters Universal TC adapter
thermocouple adapter) thermocouple adapter)
56
Thermal Imagers

Temperature changes can indicate problems in many everyday applica-


tions and a thermal imager makes it quick and easy to visually check
surface temperatures. Often problems can be discovered before contact
measurements even need to be made. Fluke offers a complete range of
handheld thermal imagers for both industrial and building diagnostic
applications. Models are available for any budget.

57
Ti Series Thermal Imagers

Find it, fix it, fast! IR-Fusion® Technology: Infrared and


Temperature changes can indicate problems visual images fused together in one image
in many areas you see everyday, some
include: See things both ways - Infrared and
• Inside electrical distribution and service visual (visible light) images fused
(Switch gear, panels, controls, together communicating critical
fuses,transformers, receptacles, lighting, information faster and easier –
conductors, bus bars, motor control traditional infrared images are no longer
centers) enough. Patented IR-Fusion® Technology,
• Motors, pumps and mechanical (Electric only available from Fluke, simultaneously
motors and generators, pumps, captures a digital photo and the infrared
compressors, evaporators, bearings, image and fuses them together taking
couplings, gearboxes, gaskets/seals, belts, the mystery out of IR image analysis.
rollers, disconnects)
• Process (Tanks and vessels, pipes, valves
and traps, reactors, process insulation)
• HVAC/R (air conditioning, heating, air
handlers, refrigeration)
• Outside electrical distribution - utilities
(Transformers, bushings, insulators,
transmission lines, other exterior
conductors, service connections, Full IR Picture-in-Picture Alpha Blending
disconnects, capacitor banks)

www.fluke.eu/ti

IR/Visible Alarm Full Visible Light

Overheating bearing cap Three-phase switch-gear


load imbalance

SmartView® Software
Fluke SmartView® software is included with each Fluke
Thermal Imager. This powerful software is a modular
suite of tools that annotates, views, edits and analyzes
IR images.
Overheated motor Cool corner in a building It also generates fully customizable and professional-
looking reports in a few easy steps. The IR-Fusion
technology is fully supported.

Thermal imaging
application video
This video covers the principles of thermal
imaging and looks at using this powerful
troubleshooting technology in electrical,
electro-mechanical and process control
applications. Go to www.fluke.co.uk/ti or
www.fluke.eu/ti to see the video. FREE webinars/webcasts on
Thermal Imaging
Keep up-to-date on the latest troubleshooting
techniques. Attend a FREE Fluke webinar (web-based
seminar) about thermal imaging applications.
Go to www.fluke.eu/ti for more information.

58
CRange IRWindows

Increase the safety and speed of electrical


thermography
Infrared windows mount into panel doors • Reduce the arc flash risk associated
and covers for switchgear, transformers, with electrical thermography
bus bars and other live electrical • Increase efficiency as thermographer
equipment, allowing Infrared, Ultraviolet, can work alone without being
Visual and IRfusion technologies to be accompanied by an electrician to isolate
used without exposing personnel to live and open panels
equipment. • Stay safety compliant with NFPA70E
All infrared windows from Fluke use and other safety protocols and leave the
the unique Quadraband™ multispectral panels closed
optic, allowing inspection with any • Extend the life of your equipment with
camera for total flexibility both now and more frequent IR scans
in the future. • Easy to install
• Durable enough to withstand extreme
outdoor conditions yet practical for
indoor applications as well.

Specifications
(Check the Fluke web for detailed specifications)

FLK-075-CLKT FLK-100-CLKT
Optic Data
Crystal Insert Diameter 75 mm 100 mm
Viewing Aperture Diameter 68 mm 89 mm
Viewing Aperture Area 3632 mm2 6322 mm2
Thickness 2 mm 4 mm
CLIRVU Coating O O
Shortwave IR Capable O O
Midwave IR Capable O O
Longwave IR Capable O O
Ultraviolet (UV) Capable O O
Visual Capable O O
Fusion Capable O O
General
Maximum Temperature
Gaskets 250º C
Body 659 º C
Included Accessories Optic 1400º C
Installation CD, self-adhesive drilling Gaskets Low Smoke & Fume (LSF) compliant silicone
template, security access key, warranty IP rating IP65
NEMA rating Typo 3/12 (UL & CSA Third Party Certified)
statement.
Vibration rating IEC60068-2-6
Humidity rating IEC60068-2-3
Ordering Information Pull out strength Up to 630 kg

FLK-075-CLKT 75mm C-Range IR Window,


Kwik Twist
FLK-100-CLKT 100mm C-Range IR Window, Warranty: Lifetime replacement against manufacturing defects
Kwik Twist
IP-200-UK Window Installation Kit
220/240V

59
Ti9/Ti10
Electrical Thermal Imagers

The rugged and affordable tools for


electricians and technicians
Get the full picture instantly with the • Enhanced problem detection and
Fluke Ti9/Ti10 thermal imagers. Built analysis capabilities with patent
for tough work environments, these pending
fully radiometric imagers are ideal for IR-Fusion® Technology (Ti10)
detecting problems in a wide range of • Intuitive, three-button menu is easy to
equipment including switchgear, motor use ... simply navigate with the push of
control centers and lighting systems. a thumb
• Store more than 3.000 screen images
• Delivers the clear images to find (.bmp format) or 1.200 fully radiometric
problems fast with its 160x120 sensor images (.IS2 format) on included 2 GB
• Even the smallest details become SD memory card
visible with the large, widescreen full • The Fluke Ti9 can be upgraded to a full
Fluke Ti10 color LCD display Fluke Ti10 with IR-Fusion at a later time.
• Optimized for field use in harsh work
environments
- Engineered and tested to withstand a
2 meter drop
- Withstands dust and water – tested to
an IP54 rating
- Innovative protective lens cover
protects the lens when not in use

Specifications
(Check the Fluke web for detailed specifications)

Fluke Ti9 Fluke Ti10


Thermal imaging performance
Detector type 160 x 120 Focal Plane Array, uncooled microbolometer
Field of view (FOV) 23 º horizontal x 17 º vertical
New Spatial resolution (IFOV)
Min focus distance
2.5 mrad
15 cm
Thermal sensitivity (NETD) ≤0.2 °C at 30 °C (200 mK)
Minimum span (Auto/Manual) 10 ˚C / 5 ˚C
Fluke Ti9 Focus Manual
Visual imaging performance
Min focus distance 46 cm
On camera operating modes Picture-in-Picture and full screen IR
Visible light camera 1.3 MegaPixel
Temperature measurement
Temperature range -20 ˚C to 250 ˚C
Accuracy ± 5 °C or 5%
Measurement modes Center point
Image presentation
Digital display 9.1 cm (3.6") landscape color VGA (640x480) LCD
LCD backlight Selectable bright or auto
Palettes Ironbow, blue-red, high contrast, grey
Image and data storage
Storage medium 2GB SD Card (3000 .bmp IR images/1200 .IS2 images)
File formats supported JPG, JPEG, JPE, JFIF, BMP, GIF, DIB, PNG, TIF, and TIFF
Controls and adjustments
Set-up controls Date/time,˚C/˚F, language
Language selection Eng, ger, fre, spa, por, ita, swe, fin, rus, cze, pol, tur
Image controls Smooth auto scaling and manual scaling
Power
Battery type Internal rechargeable battery NiMh (included)
Battery operating time 3 to 4 hours continuous operation
Complete package

Included Accessories
SmartView® software
2 GB SD card Battery life: 3 to 4 hours continuous operation
SD card reader Water and dust resistant: IP54
Rugged hard carrying case Size (HxWxD): 267 x 127 x 152 mm
Weight: 1.2 kg
Soft carrying case
Two Years Warranty
Hand strap
Rechargeable battery
AC charger/power supply Recommended Accessories
User manual
Training DVD

Ordering Information
Fluke Ti9 Electrical Thermal Imager Ti-Visor Ti-Car Charger Ti-TRIPOD
Tripod Mounting Base
Sun Visor Car charger
Fluke Ti10 Thermal Imager (for complete Ti Series) Accessories
60 (for complete Ti Series)
Ti25/Ti32
Industrial Thermal Imagers

New The ultimate tools for troubleshooting and


maintenance
The Fluke Ti32 combines a powerful NETD of 0.1ºC for the Ti25 and 0.05ºC for
320x240 sensor into the award winning, the Ti32 to view the smallest details.
rugged design of the Fluke Ti25, For added versatility and special
delivering the first industrial grade, high applications, the Ti32 includes two field-
performance thermal imager. The result swappable, rechargeable batteries. Use
is strikingly crisp, detailed images that, the optional telephoto and wide-angle
blended with patented IR-Fusion®, are lens to bring distant and wide views into
sure to make a lasting impression. sharp focus.
The Fluke Ti32 and Ti25 have all the
features of the Fluke Ti10, but with an

Specifications
Fluke Ti32
(Check the Fluke web for detailed specifications)

Fluke Ti25 Fluke Ti32


Thermal imaging performance
Detector type 160 x 120 Focal Plane Array, uncooled 320 x 240 Focal Plane Array, uncooled
microbolometer microbolometer
Field of view (FOV) 23 º horizontal x 17 º vertical
Spatial resolution (IFOV) 2.5 mrad 1.25 mrad
Min focus distance 15 cm
Thermal sensitivity (NETD) ≤0.1 °C at 30 °C (100 mK) ≤0.05 °C at 30 °C (50 mK)
Minimum span (Auto/Manual) 2.5 ˚C / 5 ˚C
Focus Manual
Optional lenses
Telephoto infrared lens type O
Wide-angle infrared lens type O
Visual imaging performance
Min focus distance 46 cm
On camera operating modes Picture-in-Picture and full screen IR plus Blending
Color Alarm High temperature alarm
Visible light camera 1.3 MegaPixel 2.0 MegaPixel
Temperature measurement
Temperature range -20 ˚C to 350 ˚C -20 ˚C to 600 ˚C
Accuracy ± 2 °C or 2%
Measurement modes Center point and hot and cold markers
Image presentation
Fluke Ti25 Digital display 9.1 cm (3.6") landscape color VGA (640x480) LCD
LCD backlight Selectable bright or auto
Palettes Ironbow, Blue-Red, High Contrast, Amber, Hot Ironbow, Blue-Red, High Contrast, Amber,
Metal, Grey Amber Inverted, Hot Metal, Grayscale,
Grayscale Inverted
Palettes Ultra Contrast O
Voice Annotation
Voice annotation O O
Image and data storage
Storage medium 2GB SD Card (3000 .bmp IR images/1200 .IS2 images)
File formats supported JPG, JPEG, JPE, JFIF, BMP, GIF, DIB, PNG, TIF, and TIFF
Controls and adjustments
Date/time, Cº/ºF, language
On screen emissivity correction
Set-up controls On-screen reflected background temperature compensation
On-screen transmission correction
Language selection Eng, ger, fre, spa, por, ita, swe, fin, rus, cze, pol, tur
Image controls Smooth auto scaling and manual scaling
Power
Battery type Internal rechargeable battery NiMh (included) Two replaceable rechargeable battery packs
(Lithium ion)
Battery operating time 3 to 4 hours continuous operation 4+ hours per battery pack
Complete package

Included Accessories
SmartView® software Water and dust resistant: IP54
2 GB SD card Size (HxWxD): Ti25: 267 x 127 x 152 mm
SD card reader Ti32: 277 x 122 x 170 mm
Rugged hard carrying case Weight: Ti25: 1.2 kg
Soft carrying case Ti32: 1.05 kg
Hand strap Two Years Warranty
Rechargeable battery
AC charger/power supply Recommended Accessories
User manual
Training DVD

Ordering Information
Fluke Ti25 Industrial Thermal Imager FLK-LENS/TELE1 FLK/LENS/WIDE Ti-Car Charger FLK-TI-SPB3 FLK-TI-SBC3
Fluke Ti32 Industrial Thermal Imager Telephoto Infrared Lens Wide-angle Infrared Lens Car charger Extra battery (Ti32) Charging base (Ti32)
(Ti32) (Ti32) 61
TiRx/TiR
Thermal Imagers
for Building Inspection

Optimized for energy audits, restoration and


remediation
The affordable rugged Fluke TiRx and TiR - Innovative protective lens cover
Thermal Imagers are workhorse tools protects the lens when not in use
for the demands of building envelope, • Enhanced problem detection and
restoration and remediation, inspection analysis capabilities with patent pending
and roofing applications. Whether IR-Fusion® Technology (TiR)
to perform energy audits, locate the • Intuitive, three-button menu is easy to
origins of construction problem or to use ... simply navigate with the push of a
find roof leaks, the TiRx and TiR offer thumb
an economical solution for complete • Store more than 3.000 screen images
detection, analysis and documentation. (.bmp format) or 1.200 fully radiometric
images (.IS2 format) on included 2 GB SD
• Delivers the clear images to find memory card
Fluke TiR problems fast with its 160x120 sensor • The Fluke TiRx can be upgraded to a full
• Even the smallest details become Fluke TiR with IR-Fusion at a later time.
visible with the large, widescreen full
color LCD display
• Optimized for field use in harsh work
environments
- Engineered and tested to withstand
a 2 meter drop
- Withstands dust and water – tested
to an IP54 rating

Specifications
(Check the Fluke web for detailed specifications)

New Fluke TiRx Fluke TiR


Thermal imaging performance
Detector type 160 x 120 Focal Plane Array, uncooled microbolometer
Field of view (FOV) 23 º horizontal x 17 º vertical
Spatial resolution (IFOV) 2.5 mrad
Fluke TiRx Min focus distance 15 cm
Thermal sensitivity (NETD) ≤0.1 °C at 30 °C (100 mK)
Minimum span (Auto/Manual) 2.5 ˚C / 5 ˚C
Focus Manual
Visual imaging performance
Min focus distance 46 cm
On camera operating modes Picture-in-Picture and full screen IR
Visible light camera 1.3 MegaPixel
Temperature measurement
Temperature range -20 ˚C to 100 ˚C
Accuracy ± 5 °C or 5%
Measurement modes Center point
Image presentation
Digital display 9.1 cm (3.6”) landscape color VGA (640x480) LCD
LCD backlight Selectable bright or auto
Palettes Ironbow, blue-red, high contrast, grey
Image and data storage
Storage medium 2GB SD Card (3000 .bmp IR images/1200 .IS2 images)
File formats supported JPG, JPEG, JPE, JFIF, BMP, GIF, DIB, PNG, TIF, and TIFF
Controls and adjustments
Set-up controls Date/time, ˚C/˚F, language
Language selection Eng, ger, fre, spa, por, ita, swe, fin, rus, cze, pol, tur
Image controls Smooth auto scaling and manual scaling
Power
Complete package
Battery type Internal rechargeable battery NiMh (included)
Battery operating time 3 to 4 hours continuous operation

Included Accessories
SmartView® software Water and dust resistant: IP54
2 GB SD card Size (HxWxD): 267 x 127 x 152 mm
SD card reader Weight: 1.2 kg
Rugged hard carrying case Two Years Warranty
Soft carrying case
Hand strap
Rechargeable battery
AC charger/power supply Recommended Accessories
User manual
Training DVD

Ordering Information
Fluke TiRx Inspector Thermal Imager Ti-Visor Ti-Car Charger Ti-TRIPOD
Fluke TiR Thermal Imager Sun Visor Car charger Tripod Mounting Base
62 (for complete Ti Series) Accessories
(for complete Ti Series)
TiR1/TiR32
Thermal Imagers
for Building Diagnostics

New
The top professional’s choice
The TiR1 and TiR32 Thermal Imagers are TiR32 to identify even small temperature
the top professional’s choice for building differences that could indicate problems.
diagnostics. With its 320 x 240 sensor, For added versatility and special
the TiR32 delivers the clear, crisp images applications, the TiR32 includes dewpoint
needed to find problems fast. The Fluke measurements and two field-swappable,
TiR1 and TiR32 have all the features rechargeable batteries. Use the optional
of the Fluke TiR, but with an NETD of telephoto and wide-angle lens to bring
0.07ºC for the TiR1 and 0.05ºC for the distant and wide views into sharp focus.

Fluke TiR32
Specifications
(Check the Fluke web for detailed specifications)

Fluke TiR1 Fluke TiR32


Thermal imaging performance
Detector type 160 x 120 Focal Plane Array, uncooled 320 x 240 Focal Plane Array, uncooled
microbolometer microbolometer
Field of view (FOV) 23 º horizontal x 17 º vertical
Spatial resolution (IFOV) 2.5 mrad 1.25 mrad
Min focus distance 15 cm
Thermal sensitivity (NETD) ≤0.07 °C at 30 °C (70 mK) ≤0.05 °C at 30 °C (50 mK)
Minimum span (Auto/Manual) 2.5 ˚C / 3 ˚C
Focus Manual
Optional lenses
Telephoto infrared lens type O
Wide-angle infrared lens type O
Visual imaging performance
Min focus distance 46 cm
On camera operating modes Picture-in-Picture and full screen IR plus Blending
Color Alarm Dewpoint alarm
Visible light camera 1.3 MegaPixel 2.0 MegaPixel
Temperature measurement
Temperature range -20 ˚C to 100 ˚C -20 ˚C to 150 ˚C
Fluke TiR1
Accuracy ± 2 °C or 2%
Measurement modes Center point and hot and cold markers
Image presentation
Digital display 9.1 cm (3.6") landscape color VGA (640x480) LCD
LCD backlight Selectable bright or auto
Palettes Ironbow, Blue-Red, High Contrast, Amber, Hot Ironbow, Blue-Red, High Contrast, Amber,
Metal, Grey Amber Inverted, Hot Metal, Grayscale,
Grayscale Inverted
Palettes Ultra Contrast O
Voice Annotation
Voice annotation O O
Image and data storage
Storage medium 2GB SD Card (3000 .bmp IR images/1200 .IS2 IR-Fusion images)
File formats supported JPG, JPEG, JPE, JFIF, BMP, GIF, DIB, PNG, TIF, and TIFF
Controls and adjustments
Date/time, Cº/ºF, language
On screen emissivity correction
Set-up controls On-screen reflected background temperature compensation
On-screen transmission correction
Language selection Eng, ger, fre, spa, por, ita, swe, fin, rus, cze, pol, tur
Image controls Smooth auto scaling and manual scaling
Power
Battery type Internal rechargeable battery NiMh (included) Two replaceable rechargeable battery packs
(Lithium ion)
Complete package Battery operating time 3 to 4 hours continuous operation 4+ hours per battery pack

Included Accessories
SmartView® software Water and dust resistant: IP54
2 GB SD card Size (HxWxD): TiR1: 267 x 127 x 152 mm
SD card reader TiR32: 277 x 122 x 170 mm
Rugged hard carrying case Weight: TiR1: 1.2 kg
Soft carrying case TiR32: 1.05 kg
Hand strap Two Years Warranty
Rechargeable battery
AC charger/power supply Recommended Accessories
User manual
Training DVD

Ordering Information
Fluke TiR1 Thermal Imager for Building
Diagnostics FLK-LENS/TELE1 FLK/LENS/WIDE Ti-Car Charger FLK-TI-SPB3 FLK-TI-SBC3
Fluke TiR32 Thermal Imager for Building Telephoto Infrared Lens Wide-angle Infrared Lens Car charger Extra battery (Ti32) Charging base (Ti32)
Diagnostics (Ti32) (Ti32) 63
Laser Distance Meters

The Fluke Laser Distance Meters bring you the most advanced
measuring technology. Unlike ultrasonic distance meters with laser
pointers, these meters use a precision narrow laser beam that can
avoid the common errors caused by extraneous objects near
measurement targets.

64
421D, 416D, 411D
Laser Distance Meters

Professional-grade laser distance


New measuring tools that are fast, easy to use,
and fit in your pocket.
The Fluke laser distance meters bring you These compact and handy Fluke distance
the most advanced measuring technology. meters are designed for indoor, and limited
These meters are fast, accurate, durable, and outdoor applications. Addition, subtraction,
easy to use — just point and shoot. Their area, and volume calculations could not be
straightforward design and easy, one-button simpler. The extra bright laser is clearly
operation mean you spend less time visible so you can see your targeting point
measuring. Unlike ultrasonic distance meters even if an object is hard-to-reach or distant.
with laser pointers, the Fluke 421D, 416D The Fluke 421D, 416D and 411D have a large
and 411D use a precision narrow laser beam LCD screen and buttons positioned for one-
that can avoid the common errors caused by handed measurements.
extraneous objects near measurement
targets.

Fluke 421D Features


411D 416D 421D
Reduction of estimation errors, saving both time and money O O O
Instant measurement with one-button operation O O O
Easy targeting with bright laser O O O
Quick calculation of area (square footage) and volume O O O
Easy addition and subtraction of measurements O O O
Improved battery life from automatic shut-off feature O O O
Pythagoras calculation for determining distance indirectly from two other O O O
measurements
Pouch O O O
Ability to view more with large, 3-line display with backlight O O
Ability to measure up to 30 m 60 m 100 m
Storage capacity of measurements for quick recall of distance - 10 20
MIN/MAX function O O
Enhanced Pythagoras calculation for determining distance indirectly from O O
three other measurements
Audible feedback of on and off modes O O
Fluke 411D Fluke 416D Strong environment protection with IP54 (water spray & dust proof) sealing O O
Audible feedback for taking room angle and incremental measurements O
± 45° Tilt sensor for taking indirect measurements in hard to reach areas O
Tripod mode allows you to mount to a tripod for measuring long distances O
Built in light sensor for activating the backlight saving battery life O
Corner angle feature, allows you to determine the angle of a corner O

Specifications
(Check the Fluke web for detailed specifications)

Fluke 411D Fluke 416D Fluke 421D


Range (for extended distances, use a target plate) 30 m 60 m 100 m
Accuracy ± 3 mm ± 1.5 mm ± 1.5 mm
Measurement units 00.000 m 00.000 m 00.000 m
411D/62 Kit Measurement storage 10 locations 20 locations
Combo kit includes:
Backlight O O
- Fluke 62 Mini IR Thermometer
Automatic power off After 180 seconds After 180 seconds After 360 seconds
- Fluke 411D Laser Distance Meter
- Soft pouch for each model
Operating temperature: 0°C to 40°C Size (HxWxD): 411D: 123 mm x 50 mm x 26 mm
Storage temperature: -25°C to 70°C 416D: 135 mm x 46 mm x 31 mm
Operating altitude: up to 3500 m 421D: 127 mm x 52 mm x 25 mm
Battery Life: 411D: up to 3000 readings Weight: 411D: 0.150 kg
Included Accessories 416D, 421D: up to 5000 readings 416D: 0.110 kg
Two AAA batteries, Users manual on CD, 421D: 0.125 kg
Quick start guide, Nylon carrying case, Warranty: 2 years
Wrist wrap (421D)

Ordering Information
Fluke 411D Laser Distance Meter
Fluke 416D Laser Distance Meter
Fluke 421D Laser Distance Meter 65
Indoor Air Quality Tools

In response to the growing importance of air quality in buildings,


workplaces and homes, Fluke offers you a range of tools that monitor
temperature, humidity, air velocity, particulate, and carbon monoxide
levels. These tools help you to quickly and easily troubleshoot and
maintain indoor air quality, as well as to verify the efficient operation of
heating, ventilation and air conditioning systems.

66
975 AirMeter

Combined inspection tool for complete air


quality inspections
The Fluke 975 AirMeter combines five air • Simultaneously measures, logs, and
monitoring tools into one, rugged and displays temperature, humidity, CO2,
easy-to-use handheld tool. Use the Fluke and CO on a bright, backlit LCD display
975 to verify the efficient operation of • One-touch air flow and velocity
heating, ventilation and air conditioning measurements with available probe
systems, and test for dangerous carbon • Min/Max/Average on all measured and
monoxide leaks in all types of buildings. calculated readings
• Audible and visual threshold alarms
• Multi-language user interface
• Extensive discrete or continuous data
logging capacity, down-loadable to PC
via USB interface

Specifications
(Check the Fluke web for detailed specifications)

Feature Range Display resolution Accuracy


Measured specifications
Temperature -20 °C to 60 °C 0.1 °C ± 0.9 °C from 40 °C to 60 °C
± 0.5 °C from 5 °C to 40 °C
± 1.1 °C from -20 °C to 5 °C
Relative humidity 10 % to 90 % RH non- 1% ± 2 % RH (10 % RH
condensing to 90 % RH)
Air velocity 50 fpm to 3000 fpm 1 fpm 4 % or 4 fpm*
0.25 m/sec to 15 m/sec 0.005m/sec 3 % or 0.015 m/sec*
whichever is greater
*Accuracy specification only valid
for velocity readings above 50 fpm.
CO2 0 to 5000 ppm 1 ppm Warm up time 1 min
(5 minutes for full specification)
2.75 % + 75 ppm
CO 0 to 500 ppm 1 ppm ± 5 % or ± 3 ppm,
whichever is greater,
@ 20 °C and 50 % RH
Calculated specifications
Dew point temperature -44 °C to 57 °C 0.1 °C ± 1 °C when temp: -20 °C to 60 °C
RH: 40 % to 90 %
Fluke 975 ± 2 °C when temp: -20 °C to 60 °C
RH: 20 % to 40 %
± 4 °C when RH: 10 % to 20 %
Wet bulb temperature -16 °C to 57 °C 0.1 °C ± 1.2 °C when RH: 20 % to 90 %
temp: -20 °C to 60 °C
± 2.1 °C when RH: 10 % to 20 %
Volume flow rate (in a duct) 0 to 3,965 M3/m 0 to 0.001 M3/min (1 cfm) N/A: The volume flow
140,000 cfm) calculation will be a simple average
of the data points times the
duct area
% outside air (based on temperature) 0 to 100 % 0.1 % N/A
% outside air (based on CO2) 0 to 100 % 0.1 % N/A

Operating temperature Shock and vibration: MIL-PRF-28800F, Class 2


(CO and CO2 sensors): -20 °C to 50 °C Battery: Rechargeable Li-Ion (primary), three-
Operating temperature AA (backup)
(all other functions): -20 °C to 60 °C Weight: 0.544 kg
Storage temperature: -20 °C to 60 °C Size (HxWxD): 28.7 cm x 11.43 cm x 5.08 cm
Humidity: 10% to 90% Data logging: 25,000 records (continuous),
Altitude: Up to 2000 m 99 records (discrete)
Multilanguage interface: English, French,
Spanish, Portuguese and German
Two-year warranty
Included Accessories
A4 alkaline batteries (3), Users Manual,
Calibration Cap, FlukeView Forms Software,
Power Adapter, International Power Plugs,
Air Velocity Probe (Fluke 975V only)

Ordering Information Recommended Accessories


Fluke 975 AirMeter
Fluke 975V AirMeter with Velocity
975CK Airmeter Calibration Kit
975R Regulator
975VP Air Velocity Probe
975VP
AirMeter Velocity Probe
67
922 Airflow Meter
Measures pressure, air flow and velocity for
maintaining balanced and comfortable
ventilation
The Fluke 922 makes airflow • Provides differential and static pressure,
measurements easy by combining air velocity and flow readings
pressure, air flow, and velocity into a • Convenient colored hoses help you
single, rugged meter. Compatible with properly diagnose pressure readings
most Pitot tubes, the Fluke 922 allows • Bright, backlit display for clear viewing
technicians to conveniently enter in all environments
their duct shape and dimensions for • Min/Max/Average/Hold functions for
maximum measurement accuracy. easy data analysis
• Auto power off saves battery life
Use the Fluke 922 to: Ensure proper air
flow balance and maintain a comfortable
environment; measure pressure drops
across filters and coils; match ventilation
to occupant loads; monitor indoor vs.
outdoor pressure relationships and
manage the building envelope; and
perform duct traversals for accurate
airflow readings.
Specifications
(Check the Fluke web for detailed specifications)

Feature Range Resolution Accuracy


Operating Specifications
Air Pressure ± 4000 Pascals 1 Pascal ± 1% +1 Pascal
± 16 in H2O 0.001 in H2O ± 1% + 0.01 in H2O
± 400 mm H2O 0.1 mm H2O ± 1% + 0.1 mm H2O
± 40 mbar 0.01 mbar ± 1% +0.01 mbar
± 0.6 PSI 0.0001 PSI ± 1% + 0.0001 PSI
Air Velocity 250 to 16,000 fpm 1 fpm ± 2.5 % of reading at 10 m/s
1 to 80 m/s 0.001 m/s (2000 p/min)
Air Flow (Volume) 0 to 99,999 cfm 1 cfm Accuracy is a function of
Fluke 922
0 to 99,999 m3/hr 1 m3/hr velocity and duct size
0 to 99,999 l/s 1 l/s
Temperature 0 °C to 50 °C 0.1°C ± 1 % + 2 °C

General Specifications
General specifications
Operating Temperature 0 ºC to +50 ºC
Storage Temperature -40 ºC to +60 ºC
Operating Relative Humidity Non condensing (<10 ºC)
90% RH (10 ºC to 30 ºC)
75% RH (30 ºC to 40 ºC)
45% RH (40 ºC to 50 ºC) Without Condensation
IP Rating IP40
Operating Altitude 2000 m
Storage Altitude 12000 m
EMI, RFI, EMC Meets requirements for EN61326-1
Vibration MIL-PREF-28800F, Class 3
Max Pressure at Each Port 10 PSI

Data Storage: 99 readings


Size (HxWxD): 175 x 775 x 419 mm
Included Accessories Weight: 0.64 kg
Fluke 922: Two Rubber Hoses, Wrist Strap, Four Battery: Four AA batteries
AA Batteries 1.5 V Alkaline, Users Manual and Battery Life: 375 hours without backlight,
Soft Carrying Case 80 hours with backlight
Fluke 922 Kit Includes: Fluke 922 Airflow Meter, Two Year Warranty
30.48 cm Pitot tube, ToolPak, Two Rubber
Hoses, Wrist Strap, Four AA Batteries 1.5 V
Alkaline, Users Manual and Hard Carrying
Case
Fluke 922/Kit

Ordering Information Recommended Accessories


Fluke 922 Air Flow Meter
Fluke 922/Kit Airflow Meter with
30.48 cm Pitot Tube

PT12 TPAK
Pitot Tube, 30.48 cm Toolpak
See page 120
68
971 Temperature Humidity Meter
Carbon Monoxide Meters

Fluke 971
Temperature Humidity Meter
Quickly take accurate humidity and • Simultaneously measures humidity and
temperature readings in the air. temperature
Temperature and humidity are two • Measures dew point and wet bulb
important factors in maintaining • 99 record storage capacity
optimal comfort levels and good indoor • Min/Max/Avg Data Hold
air quality. The Fluke 971 is invaluable • Ergonomic design with built-in belt clip
for facility maintenance and utility and protective holster
technicians, HVAC-service contractors, • Backlit, dual readings display
and specialists who assess indoor air • Twist-open protective cap
quality (IAQ). Lightweight, rugged, and • Low battery indicator
easy to hold, the Fluke 971 is the perfect
tool for monitoring problem areas.

Specifications

Temperature range -20 ºC to 60 ºC


Temperature accuracy
0 ºC to 45 ºC ± 0.5 0C
-20 ºC to 0 ºC and 45 ºC to 60 ºC ± 1.0 ºC
Resolution 0.1 ºC
Response time (temperature) 500 ms
Temperature sensor type NTC
Relative humidity range 5% to 95% R.H.
Fluke 971 Relative humidity accuracy
10% to 90% R.H. @ 23 ºC ± 2.5 % R.H.
<10%, >90% R.H. @ 23 ºC ± 5.0 % R.H.
Humidity sensor Electronic capacitance polymer film sensor
Other useful tools Data storage 99 points
Response time (humidity) For 90% of total range - 60 sec with 1 m/s air movement

Operating temperature: Safety: Complies with EN61326-1


Temperature: -20 °C to 60 °C Weight: 0.188 kg
Humidity: 0 °C to 60 °C Size (HxWxD): 194 mm x 60 mm x 34 mm
Storage temperature: : -20 °C to 55 °C One Year Warranty
Battery life: 4 AAA alkaline, 200 hours
Fluke 561 Fluke 416D
Combined Contact Laser Distance Meter
and Non-contact See page 65.
Thermometer Carbon Monoxide Meters
See page 54.

CO-220 Carbon Monoxide Meter


The CO-220 Carbon Monoxide Meter makes it easy to take quick Fluke CO-220
and accurate measurements of CO levels. A large, backlit LCD
Included Accessories display shows CO levels from 0 to 1000 PPM. The MAX Hold
Fluke CO-220: C50 soft carrying case and
function stores and displays the maximum CO level.
battery
1 year warranty.
Ordering Information
Fluke 971 Temperature Humidity
Meter
Fluke CO-220 Carbon Monoxide Meter
CO-205 Aspirator Kit CO-205 Aspirator Kit
Allows flue gas samples up to 371°C to be drawn with the
CO-220 for carbon monoxide measurement. Fluke CO-205
1 year warranty.

69
983 Particle Counter /
RLD2 Leak Detector Flashlight

Easy to use tool for troubleshooting and


maintaining indoor air quality
The Fluke 983 Particle Counter • Simultaneously measure and display 6
simultaneously measures and displays channels of particle sizes, temperature
six channels of particle size distribution, and humidity
temperature and humidity. This compact, • Measure particle size down to 0.3 μm
lightweight, self-contained tool allows • Selectable sample time, count data,
for one-handed operation. As the Fluke programmable delay
983 doesn’t require level holding, it can • Store 5000 records of date, time, counts,
make accurate measurements in any relative humidity, temperature, sample
position. The 8 hour rechargeable battery volumes, alarms and location label
together with a large 5000 sample record • Upload stored data to a PC with
allows for complete air quality surveys in included software
one go. The Fluke 983 is the ideal tool for • Compact, self-contained package allows
determining size distribution of airborne for one-handed operation
particles or tracking down a particle • Intuitive, easy-to-use user interface
source. • Always ready to run, with no fluids to
refill
• Backlit LCD for use in any lighting
condition

Specifications

6 size channels 0.3, 0.5, 1.0, 2.0, 5.0, 10.0 μm


Flow rate 0.1 cfm (2.83 L/min) controlled by internal pump
Count modes Concentration, totalize, audio
Counting efficiency 50 % @ 0.3 μm; 100 % for particles > 0.45 μm (per JIS B9921:1997)
Zero count 1 count/5 minute (per JIS B9921:1997)
Fluke 983
Coincidence loss 5 % at 56,000 particles per m3
Relative humidity ± 7 %, 20 % to 90 %, non-condensing
Temperature ± 3 °C, 10 °C to 40 °C
Data storage 5000 sample records (rotating buffer) of date, time, counts, relative humidity,
temperature, sample volumes, alarms, label
Alarms Counts, low battery, sensor fail
Delay time 0 to 24 hours
Sample inlet Isokinetic probe
Interface RS-232 and RS-485 via RJ-45
Calibration PSL particles in air (NIST traceable)

Operating temperature: 10 °C to 40 °C, 20 % to Rechargeable battery: NiMH, 4.8V at 4.5 Ah;


90 % relative humidity, non-condensing replaceable
Storage temperature: -10 °C to 50 °C, up to Size (HxWxD): 209 mm x 114 mm x 57 mm
90 % relative humidity, non-condensing Weight: 1 kg
Power: AC adapter, 90 to 250 V AC, 50 to 60 Hz Warranty: 1 year
Battery life/recharge time: 8 hours/2 hours

Included Accessories RLD2 Leak Detector Flashlight


Fluke 983:
Certificate of Calibration (NIST)
Isokinetic probe
Zero count filter New RLD2 Leak Detector Flashlight.
Windows-compatible software download Leak detection made easy. The compact RLD2
utility uncovers refrigerant leaks instantly. Use the UV
DB9 to RS-232 adapter and cable light to find the leakage area, then, use the laser
High purity tubing pointer to pinpoint the exact leak location.
1/8 in. hose barb adapter
Power supply • Six UV LEDs detect leak detection dyes
Operation manual • Laser pointer clearly locates center of the UV
Hard molded carrying case field for accuracy
Fluke RLD2: Key chain carabiner and batteries. • Three LED flashlight with 100,000 hour LED life
• Operating temperature 0ºC to 50ºC
Ordering Information • Four operating modes: flashlight, UV light, laser
Fluke 983 Particle Counter light, UV/laser light combination
Fluke RLD2 Leak Detector Flashlight • One year warranty

70
ScopeMeter® Test Tools

With the original ScopeMeter, we transformed the oscilloscope category


beyond recognition, and we still lead the way today. From rugged
solutions for industrial applications to full-colour models that pack top-
end bench oscilloscope specifications into hand-held, battery powered
instruments. In short, ScopeMeter provides you with unmatched speed,
performance and analysis power while working on site.

71
ScopeMeter® Test Tools

Oscilloscopes for field applications

Features
225C 215C 199C 196C 192C 125 124 123
LDC Display Color B/W
Persistence O O O O O
Waveform reference O O O O O
Automatic pass fail testing O O O O O
Cursors and zoom O O O O O Cursors
Connect and View triggering O O O O O O O O
Video triggering with line selector O O O O O O O O
Selectable pulse width triggering O O O O O
Capture and replay of last 100 screens O O O O O
Dual input TrendPlot With cursors and Zoom O O O
Memory for screens and set-ups 10 screens and setup 20 20 10
Recorder memories, each can store 100 scope screens, 2 recorder memories
a ScopeRecord or a TrendPlot

The ScopeMeter 190C Series of high 1000V Independently floating isolated outputs O O O O O
performance oscilloscopes have Meter measurements: VAC RMS, VAC+DC, Ohms,
Continuity, Diode, Amps, Temp. (ºC, ºF)
O O O O O O O O
bandwidth of 60, 100 and 200 MHz and
Waveform mathematics: A+B, A-B, AxB, A versus B O O O O O
sample rates up to 2.5 GS/s. (X-Y mode)
These instruments offer a high- Frequency Spectrum Analysis using FFT O O O O O 2)

resolution color display that has a Power measurements and VPWM O O O O O O


Capacitance and frequency measurements -/O -/O -/O -/O -/O O/O O/O O/O
fast update rate, waveform pass/fail Bus Health Test function O O O
testing and a digital persistence mode Rugged, dust and drip proof case (IP51) O O O O O O O O
– making the analysis of complex and PC and printer interface via optically isolated RS- 1) 1) 1) 1) 1) 1) 1) 1)
dynamic signals much easier. 232/USB cable
FlukeView® for Windows® Software (SW90W) 1) 1) 1) 1) 1) 1) 1) 1)

For industrial electronic or electro


mechanical applications, the 120 Series
Industrial ScopeMeter, with a 20 or OStandard equipped 1) Optional 2) Harmonics mode

40 MHz bandwidth and Connect-and-


View™ triggering for an instant, stable
display will get the job done.
Specifications
(Check the Fluke web for detailed specifications)

225C 215C 199C 196C 192C 125 124 123


Oscilloscope specifications
Bandwidth 200 MHz 100 MHz 200 MHz 100 MHz 60 MHz 40 MHz 20 MHz
Max. real time sample rate 2.5 GS/s 1 GS/s 2.5 GS/s 1 GS/s 500 25 MS/s
MS/s
Input sensitivity 2 mV/div. ...1000 V/div 5 mV/div. ...500 V/div.
Timebase range 5 ns/div. ...2 min/div. 10 ns/div. 10 ns/div. ...1min/div. 20
...2 min/ ns/div. ...1
div. min/div.
Inputs and digitizers 2 plus external trigger/DMM input 2
Independently floating isolated outputs Up to 1000 V between inputs, references and ground
Max. record length...
... in Scope mode: 3000 points per input 512 min/max points per input
... in ScopeRecorde mode: 27.500 points per input or more (5 ms/div. to
2 min/div.)
Glitch capture Up to 3 ns using Pulse Width triggering; 40 ns
50 ns peak detect at 5 μs/div. to 1 min/div.
Scope measurements cursors + 26 automatic 26
7 cursor measurements, 30 automatic measurements automatic
Automatic Vrms and watts measurement on cursor ...plus
limited part of waveform power
measure-
ments and
Vpwm
True RMS multimeter 5000 counts, single input 5000 counts, dual input
General specifications
Line power Adapter/battery charger included (BC190) Adapter/battery charger included
(PM8907)
Battery (installed) >3,5 hr Ni-MH (BP190) 7 hr Ni-MH (BP120 MH)
Size 256 x 169 x 64 mm 232 x 115 x 50 mm
Weight 2 kg 1.2 kg
Safety certified (EN61010-1) 1000 V CAT II / 600 V CAT III 600 V CAT III
Warranty 3 years on main products and 1 year on accessories

Check the Fluke web site for Technical Specifications and


72 Application Notes for the Fluke ScopeMeters
ScopeMeter® 120 Series

Three-in-one simplicity
The compact ScopeMeter 120 Series stable, reliable and repeatable display
is the rugged solution for industrial of virtually any signal - including
troubleshooting and installation motordrive and control signals - without
applications. It’s a truly integrated test touching a button. Signal changes
tool, with oscilloscope, multimeter and are instantly recognized and settings
“paperless” recorder in one affordable, adjusted for - once again - a stable
easy-to-use instrument. Find answers to display.
problems in machinery, instrumentation,
control and power systems quickly and Use TrendPlot™ to help find
easily. intermittents fast
The toughest faults to find are those
• Dual-input 40 MHz or 20 MHz digital that happen only once in a while:
oscilloscope intermittents. They can be caused by
Fluke 125 • Two 5,000 counts true-RMS digital bad connections, dust, dirt, corrosion
multimeters or simply broken wiring or connectors.
• A dual-input TrendPlot™ recorder You may not be around to see it – your
• Bus Health Test for industrial bus Fluke ScopeMeter will. In this “paperless
systems (Fluke 125) recorder” mode,
• Connect-and-View™ trigger simplicity you can plot the minimum and
for hands-off operation maximum peak values and average over
• Power Measurements and Harmonics time – up to 22 days (Fluke 190 Series) or
measurement (Fluke 125) 16 days (Fluke 120 Series).
• Shielded test leads for oscilloscope,
resistance and continuity Bus Health mode (Fluke 125)
Fluke 124
measurements Bus Health mode gives a clear “Good/
• Up to 7 hours battery operation Bad” indication for the electrical signals
• 600 V CAT III safety certified on industrial buses and networks, such
• Optically isolated interface for PC and as CAN-bus, Profi-bus, RS-232 and many
Printer connection (optional) more. The Fluke 125 validates the quality
• Rugged, compact case of the electrical signals as soon as any
electrical signals are passed along the
Connect-and-View™ triggering for network.
Fluke 123 an instant, stable display
Scope users know how difficult triggering
can be. Wrong settings show unstable
and sometimes wrong results. Fluke’s
unique Connect-and-View recognizes
signal patterns, and automatically
True RMS sets up correct triggering. It provides a

Included Accessories
PM 8907 line adapter/charger, STL120 shielded
test leads set (1 red, 1 grey), AC120 Alligator
Clips, BB120 shielded BNC adapter, BP120MH
NiMH battery pack, VPS40 wide bandwidth
Voltage Probe (Fluke 124/125), TL75 hard
point test lead, i400s current clamp (Fluke
125), Getting Started booklet, user’s manual
(cd-rom)

Ordering Information
Fluke 123 Industrial ScopeMeter® (20MHz)
Fluke 123/S Industrial ScopeMeter® (20MHz)
Connect-and-View captures even the most Bus Health mode allows for an analysis of the
+ SCC120 kit complex motor drive signals. signal quality on an industrial network.
Fluke 124 Industrial ScopeMeter® (40MHz)
Fluke 124/S Industrial ScopeMeter® (40MHz)
+ SCC120 kit
Fluke 125 Industrial ScopeMeter (40 MHz) See page 72 for specifications.
Fluke 125/S Industrial ScopeMeter (40 MHz) +
SCC120 kit Recommended Accessories
SCC120 FlukeView® Software + OC4USB
Cable + Carrying Case
OC4USB USB Interface Cable
PM9080 RS-232 Interface Cable
DP120 Differential Voltage Probe
ITP120 Isolated Trigger Probe SCC120 C125 DP120 OC4USB SCC128
See page 118 See page 76 See page 76 See page 113
SW90W FlukeView Software
BHT190 Set of 3 break-out adapters 73
(Fluke 125)
ScopeMeter® 190C Series
(incl. 225C and 215C)

Speed, performance and analysis power

For more demanding applications, the


ScopeMeter 190C Series high performance
oscilloscopes offer specifications usually
found on top-end bench instruments.
With up to 200 MHz bandwidth, 2.5 GS/s
real-time sampling and a deep memory of
27500 points per input they’re ideal for
engineers who need the full capabilities
of a high performance oscilloscope in a
handheld, battery powered instrument.

• Dual input – 60, 100 or 200 MHz models Bus Health Test (225C and 215C)
• Up to 2.5 GS/s real time sampling per input Bus Health Test analyses the electrical
• Bus Health Test capability for industrial signals on an industrial bus or network
buses, including Profi, Foundation, ModBus and gives a clear “Good”, “Weak” or “Bad”
and many more (225C and 215C) validation mark for each of the relevant
• High resolution color display parameters, presented next to the actual
• High waveform resolution of max. 3000 measurement value.
datapoints per channel The Fluke 225C and 215C can make the
• Digital Persistence for analyzing complex signal quality validation as soon as electrical
dynamic waveforms like on an analog signals are passed along the network,
scope without looking at the data content. They
Fluke 199C • Fast display update rate (> 100/sec) for find errors like improper cable connections,
seeing dynamic behavior instantaneously bad contacts, incorrect grounding and
• Connect&View™ automatic triggering, missing or superfluous terminators.
a full range of manual triggering modes
plus external triggering.
• Automatic capture and replay of
100 screens
• 27500 points per input record length using
ScopeRecord mode
• Up to 1000 V independently floating
isolated inputs
• Waveform reference for visual
comparisons and automatic pass/fail
testing of waveforms
• Vpwm function for motor drive and
frequency inverter applications.
• Waveform mathematics: Add, Subtract and
Fluke 196C Fluke 192C Multiply
• Frequency Spectrum Analysis using FFT
• X-vs-Y mode (Lissajous display) for study
of signal relationships
• Cursors, zoom and real-time clock
• 30 automatic waveform measurements
• Over 3.5 hours rechargeable Ni-MH battery Automatic capture and replay
pack of 100 screens
• Includes a 5000 count true-RMS Scope users know how frustrating it is to
multimeter and a TrendPlot™ paperless see a one time anomaly flash by, never to be
recorder seen again. Not with the ScopeMeter 190C
Series! Now you can look back in time with
ScopeMeter for medical imaging and a touch of the replay button. In normal use,
video test applications the instrument continuously memorizes
For tests on such systems, an optional the last 100 screens. Each time a new
Fluke 225C Fluke 215C configuration is available. Please check the screen is acquired, the oldest is discarded.
Fluke website for further details. At any moment you can “freeze” the last
100 screens and scroll through picture-
by-picture or replay as a ‘live’ animation.
Cursors can be used for further analysis.
You can even use the advanced trigger
capabilities to capture up to 100 specific
events. Two sets of 100 captured screens
with individual time stamps can be stored
True RMS for later recall or download to a PC.
On all inputs

74
ScopeMeter® 190C Series
(incl. 225C and 215C)

See dynamic signal Frequency Spectrum Analysis 190C FlukeView® Software for documenting,
behavior instantaneously All 190C Color ScopeMeters include archiving and analysis
The Digital Persistence mode helps to find Frequency Spectrum Analysis on Fast Fourier FlukeView® for Windows® helps you get more
anomalies and to analyze complex dynamic Transformation (FFT) analysis as a standard out of your ScopeMeter by:
signals by showing the waveforms amplitude feature. • Documenting - transfer waveforms,
distribution over time using multiple This makes it possible to identify the screens and measurement data from the
intensity levels and user selectable decay individual frequency components contained ScopeMeter to a PC. Print or import the data
time - it’s as if you’re looking at the display in a signal. The spectrum analysis function is into your report
of an analog, real time oscilloscope! A fast also handy to reveal the effects of vibration, • Archiving - create a library of waveforms
display update rate reveals signal changes signal interference or crosstalk. An automatic with your comments for easy reference and
instantaneously, useful for instance when window function assures optimal windowing, comparison
making adjustments to a system under test. although you may manually select your • Analysis - use cursors, perform spectrum
preferred time window. analysis or export data to other analysis
programs

Pulse width fluctuations are clearly visible using Digital Frequency Spectrum shows an overview of frequencies FlukeView Screen
Persistence contained in a signal.

Included Accessories
BC190 Battery Charger
BHT190 Set of 3 break-out adapters
(225C/215C)
BP190 NiMH Battery Pack
VPS210-G + VPS210-R Voltage Probe
TL75 Hard Point Test Lead Set
user’s manual (CD-Rom), Getting Started
Booklet

Ordering Information
Fluke 192C Color ScopeMeter
(60 MHz, 500 MS/s)
Fluke 196C Color ScopeMeter
(100 MHz, 1 GS/s) Thanks to the deep memory, very small parts of the waveform can be studied in full detail
Fluke 199C Color ScopeMeter using “zoom”.
(200 MHz, 2.5 GS/s)
Fluke 215C Color ScopeMeter with Bus
Health Test (100 MHz, 1 GS/s)
Fluke 225C Color ScopeMeter with Bus See page 72 for specifications.
Health Test
(200 MHz, 2.5 GS/s)
Fluke 192C/S 192C + SCC191 kit option
Fluke 196C/S 196C + SCC191 kit option
Fluke 199C/S 199C + SCC191 kit option
Fluke 215C/S 215C + SCC191 kit option Recommended Accessories
Fluke 225C/S 225C + SCC191 kit option
SCC190 SW90W FlukeView Software,
OC4USB cable, C190 briefcase
style carrying case
SCC191 SW901W FlukeView Software,
OC4USB cable, industrial style
carrying case ScopeMeter SCC191 Scopemeter SCC190 C195 OC4USB SCC198
See page 118 See page 76 See page 113
C190 Briefcase style carrying case 75
SW90W FlukeView Software
ScopeMeter® Accessories

ScopeMeter probes

VPS40 VPS210-R series VPS210-G series DP120 PM8918/301

VPS40 VPS210-R VPS210-G VPS212-R VP212-G VPS220-R VPS220-G VPS101 DP120 PM8918/301
Description Voltage Voltage Probe Set Voltage Probe Set Voltage Probe Set Voltage Probe Differential Low Pass
Probe Set Set Probe Set Filter Probe
Number and color One Black 1 Red 1 Grey 1 Red 1 Grey 1 Red 1 Grey 1 Black Red & Grey One Blue
Attenuation 10:1 10:1 10:1 100:1 1:1 200:1, 20:1 10:1
Bandwidth DC-MHz 40 200 MHz 200 MHz 200 MHz 30 MHz 20 4 kHz
Length (m) 1.2 1.2 m 2.5 m 1.2 m 1.2 m 1.5 2.5
EN 61010-2 CAT II 1000 V 1000 V 1000 V 1000 V - 1000 V -
EN 61010-2 CAT III 600 V 600 V 600 V 600 V 300 V 600 V 600 V
ScopeMeter 190 Series O O O O O O O O O
ScopeMeter 120 Series O O O O1) O1)
1) Using BB 120

PM9091/9092 PM9081 PM9082 PM9093

PM9091 PM9092 PM9081 PM9082 PM9093


Description 50 Ω BNC cable set 50 Ω BNC cable set Dual Banana plug male to Dual Banana jack female to Male BNC to dual
(1Red, 1Grey, 1Black) (1Red, 1Grey, 1Black) female BNC male BNC female BNC
Length 1.5 m 0.5 m
EN 61010-2 CAT III 300 V 300 V 600 V 600 V 600 V
ScopeMeter 190 Series O O O O O
ScopeMeter 120 Series O1) O1) O O1) O1)
1) Using BB 120

RS200 AS200-R OC4USB PM9080 PM9090

RS200 Probe Accessory Replacement Set for VPS Series Probes Battery Packs
AS200-R Probe Accessory Set, Red for VPS Series Probes BP120MH NiMH Battery Pack for 120 Series + 43B
AS200-G Probe Accessory Set, Grey for VPS Series Probes BP190 NiMH Battery Pack for 190 + 430 Series
PM9080 Optical Interface Adapter Cable for serial port
OC4USB Optical Interface Adapter Cable for USB Port
PM9090 Probe Pin Grabber Flexible Clip for VPS Series Probes
PM9094 Mini Testhook Set for PM8918 Probes
PAC91 Printer Adapter Cable

76
All accessories have a one year warranty
Power Quality Tools and Power
Analyzers

We offer an extensive range of power quality test tools for


troubleshooting, predictive maintenance and long-term recording in
industrial and utility applications. For the development and test of
electrical equipment, our high-precision power analyzers enable easy
and reliable use in the field or as a bench unit in test laboratories.

77
78
Power quality tools help pinpoint problems fast

Single phase Three phase


Basic measurements Application use VR1710 345 43B 430 1735 1740 1750 1760
RMS voltage Detailed RMS trending shows how connected loads O O O O O O O O
RMS Current behave. O O O O O(not 1743) O O
Energy studies
Measure V, I, kW, Cos/DPF, kWhr Get detailed power and energy consumption O O O O O O O
Measure MIN/MAX and AVG values profiles during energy audits and pinpoint savings O O O O O O O
opportunities.
10 day logging O O O O O O O
Energy aggregation O O O O O O O
Utility meter pulse input O
Energy Loss (Eff. kW, Reactive kVAR, Unbalance
O O O O O O O
kVAR, Distortion kVAR, Neutral kVAR)
Basic harmonics study
THD measurement (V & I) Discover the source of distortion in your installation, so O O O O O O O O
Harmonics 1 to 25 for V & I that you can filter those loads or move them to separate O O O O O O O O
circuits.
Tabular values O O O O O
Neutral current measurement O O O O O
Crest factor O O O O O O
Advanced harmonics study
Full harmonic spectrum If distorting loads are causing problems in your O O O O O O O
Power harmonics installation, you need comprehensive data to intentify O O O O O
the source and create a solution.
Harmonics 1 to 50 and dc O O O O(no DC) O O
k-factor O O O O O
%Fundamental and %RMS O O O O O O
Basic Industrial PQ Troubleshooting
Oscilloscope function When troubleshooting in the field, graphical data O O O O O O
Voltage dips and swells enables you to trace the source of the problem at hand. O O O O O O
Phasor diagram O O O
Trend recording O O O O O O
Inrush current O O O O O
Advanced industrial PQ troubleshooting
Comprehensive logging capability Complex installations often require a deeper dive into O O O O O O
Transient capture measurement data. Multiple loads may be interacting O O O O O
randomly to cause a single problem.
Flicker O O O O O
EN50160 analysis O O O O
Complex System interaction event capture
O
(manual threshold setting)
Random/variable system event capture (Adaptive
O
threshold setting)
Utility PQ benchmarking
Phase sequence components Before you install sensitive loads, make sure you O O O
Interharmonics understand the existing quality of power delivered by O O O O
your utility. Comparing benchmarks over time can help
Mains signaling O O O O
pinpoint potential areas of concern.
IEC61000-4-30 Class A O O
Software
Power Quality Selection Guide

PowerLog To make use of the power data you collect, you need O O O O
PQLog software that can help analyze your findings and share O
them with equipment providers and plant management.
Power Analyze O
PQ Analyze O
FlukeView Forms O

VIDEO
Power Quality in Industrial Applications
Covers the basics of power quality and looks at the tools and inspection techniques
used to troubleshoot common problems.

Go to www.fluke.co.uk/pq or www.fluke.eu/pq to see the video


VR1710 Single-Phase Voltage
Quality Recorder

Easy-to-use solution for detecting and


recording voltage quality problems
The Fluke VR1710 is a single-phase, plug- • Clear graphical summary of data and
in voltage quality recorder that provides quick overview of key power quality
fast and easy recording of voltage trends, parameters
dropouts, harmonics and general power • Get the complete picture with Min, Max,
quality including dips and surges to help Average RMS values (1/4 cycle) with
maintenance and facilities management time stamps
personnel easily pinpoint the root cause • See the detailed with actual transient
of voltage problems. Voltage quality display (> 100 μs) with time stamp
parameters including RMS average, • Comprehensive analysis of Individual
transients, flicker, and harmonics up to harmonic and THD values with trends
the 32nd are recorded using a user-
Fluke VR1710 selected average period from
1 second to 20 minutes.

Applications
• Voltage recording – Monitors and • Flicker measurement – Quantify the
records supply voltage; measures RMS affects of switching loads on lighting
average, minimum and maximum systems.
values, and checks whether the socket • Voltage transients – Capture those
outlet is providing voltage within intermittent, momentary events that
tolerance. may be affecting your equipment; the
• Distortion measurement – Measure full waveform is captured with date,
frequency and harmonics; check timestamp, and duration.
whether the distorting loads (UPS
systems, drives, etc.) are affecting your
other equipment.

Fluke VR1710 and included accessories

PowerLog Setup – Simple set up of Actual transient display Statistical analysis of voltage event
internal clock, logging periods, and (> 100 μs) with time stamp– – reduces analysis time by tracking
intervals with default values for Quickly identify issues with included event quantities and magnitudes.
quick results. graphical software.
PowerLog View – Data presentation
showing RMS voltage and harmonic
trends, actual transients, summary
information and statistics in
accordance with EN50160.

Specifications
(Check the Fluke web for detailed specifications)

Operating voltage 70 V to 300 V


Min/Max/Avg RMS value Resolution 0.125 V
Number of events 175,000
Dips/Interruptions Yes
Includes PowerLog software Time resolution 5 ms
Voltage resolution) 0.125 V
Over-voltages Yes
Frequency Yes
Harmonics measurement EN 61000-4-7 (up to 32nd)
Flicker measurement EN 61000-4-15
Number of recording channels 1 Phase to Neutral
Included Accessories 2 Phase/Neutral to Ground
Recording time 1 day to 339 days depending on average time from 1 second to 20 minutes
Plug-in Fluke VR1710, USB cable, PowerLog Transients Yes (> 100μs)
software CD, universal power cord adapters. Frequency range 50 Hz ± 1 Hz and 60 Hz ± 1 Hz
Safety category rating CAT II 300 V

Ordering Information
Fluke VR1710 Voltage Quality Recorder Display: LED Weight: 0.8 kg
Size (HxWxD): 23 x 19.75 x 22.2 cm Two years warranty 79
345
Power Quality Clamp Meter

The ideal troubleshooting tool for modern


electrical loads
The Fluke 345 measures a wide range of • High safety rating: 600V CAT IV / 1000V
electrical parameters for troubleshooting CAT III rated for use at the service
power disturbances in single- and entrance
three-phase electrical loads. With a • ac/dc current measurements: Clamp-
bright color display to see waveforms on measurement of ac peak and dc
and trends, a low-pass filter to remove current up to 2000 A without breaking
high frequency noise, and a high EMC the circuit
immunity design, the Fluke 345 is ideal • Harmonic analysis: Analyze, display
for measurements on switching loads and log harmonics up to the 30th
such as variable speed drives, electronic harmonic (40th harmonic for 15 Hz to
lighting and UPS systems. 22 Hz)
• Verify batteries: Direct measurement
of dc ripple (%) for battery and dc
systems

Specifications
Fluke 345 (Check the Fluke web for detailed specifications)

Current measurement
DC, DC rms, AC rms All measurements DC and 15 Hz to 1 kHz.
Maximum overload 10,000 A or RMS x frequency < 400,000. Amps rms is a true rms
measurement (AC + DC).
Measuring range 0 – 2000 A dc or 1400 AC rms
Harmonics All measurements up to 30th harmonic (40th harmonic for 15 Hz to 22 Hz); Frequency
range F0 : 15 Hz to 22 Hz and 45 Hz to 65 Hz; Iacrms > 10A

Voltage measurement
DC, DC rms, AC rms All measurements DC and 15 Hz to 1 kHz. Maximum overload 1,000 V rms. Volts rms is a
true-rms measurement (AC + DC).
Measuring range 0 – 825 V DC or AC rms
Harmonics All measurements up to 30th harmonic; Frequency range F0 : 15 Hz to 22 Hz and 45 Hz
to 65 Hz; Vacrms > 1V
Watts measurement (single- and three-phase) DC, DC rms, AC rms
Measuring range 0 – 1650 kW DC or 1200 kW ac
VA measurement (single- and three-phase) DC, DC rms, AC rms
View waveforms for equipment Measuring range 0 -1650 kVA DC or 1200 kVA ac
checking and setup VAR measurement (single- and three-phase)
Measuring range 0 – 1250 kVAR
Power factor (single- and three-phase)
Measuring range 0.3 cap…1.0… 0.3 ind (72.5° cap…0°… 72.5° ind)
Displacement power factor
Measuring range 0.3 cap … 1.0 … 0.3 ind (72.5° cap ... 0° ... 72.5° ind)
Kilowatt Hour (kWHr)
Measuring range 40,000 kWHr
Scope function
Time base 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms/div
Current management:
Ranges 10 A/20 A/40 A/100 A; 200 A/400 A/1000 A/2000 A
Voltage measurement:
Ranges 4 V/10 V/20 V/40 V/100 V; 200 V/400 V/1000 V
Inrush current function All measurements dc and 15 Hz to 1 kHz
Ranges 40, 400 and 2000 A
Log parameters over time Memory Up to 50 screen shots and over 150,000 individual measurement values
to track down intermittent faults
Power supply: 1.5 V Alkaline AA MN 1500 or IEC LR6 Display: Color transmissive LCD 320 x 240 pixels
x 6 Battery (70 mm diagonal) with 2 level backlight
Battery life (typical): >10 hours (backlight on full); Digital output: USB interface to a PC
>12 hours (backlight reduced) Size (HxWxD): 300 mm x 98 mm x 52 mm
Safety: IEC 61010-1 600 V CAT IV, 1000V CAT III Jaw opening: 60 mm
(maximum input phase-phase 825V rms) double or Jaw capacity: 58 mm diameter
reinforced insulation, pollution degree 2 Weight (including batteries): 0.82 kg
Protection: IP40; EN60529 Two Year Warranty
Operating temperature: 0 °C to 50 °C

Included Accessories
Soft carrying case, Power Log software,
Test probes, Test leads, Alligator clips,
International ac adapter / battery eliminator,
Printed English User manual, Multi-language Recommended Accessories
manual on CD

Ordering Information
Fluke 345 Power Quality Clamp Meter

TLK291 TP220 AC220 TP1 C550


See page 111 See page 111 See page 112 See page 111 See page 118
80
43B Single-phase Power
Quality Analyzer

The perfect tool for tracking down


single-phase power-related problems
The Fluke 43B is the choice for capabilities of a power quality analyzer, a
diagnosing and troubleshooting power 20 MHz oscilloscope, a multimeter and a
quality and general equipment failures. data recorder in a single instrument.
Ease to use thanks to menu selection of
the power modes, it combines the

• Voltage, current, and • Continuously measure


power harmonics volts and amps on a
• Up to 51st harmonic cycle-by-cycle basis for up
• Total harmonic distortion to 16 days
(THD) • Use cursors to read time
• Phase angle of individual and date of sags and
harmonics swells

• Watts, power factor, • Connect-and-View™


COS ij, VA and VAR scope for quick waveform
• Voltage and current display
waveforms • View voltage and current
channels simultaneously
Fluke 43B

Specifications
(Check the Fluke web for detailed specifications)

Menu items Measurements Ranges Accuracy


Volts/Amps/Hz Volts 5.000 V - 1250 V ±(1%+10)
Amps 50.00A - 50.00 kA ±(1%+10)
Mains frequency 40.0 - 70.0 Hz ±(0.5%+2)
On all inputs CF Crest Factor 1,0 à 10,0 ±(5%+1)
Power Watts, VAR, VA 250 W - 1.56 GW ±(4%+4)
PF, DPF, COS ij 0.25 W-0.9 ±0.04
0.90-1.00 ±0.03
Harmonics Volts 1 st to 51 st harmonic ±(3%+2) to ±(15%+5)
Amps 1 st to 51 st ±(3%+8) to ±(15%+5)
True RMS Watts 1 st to 51 st ±(5%+2) to ±(30%+5)
K-factor 1.0 to 30.0 ±10%
Sags & Swells Voltage and Current 4 min-16 days selectable ±(2%+10)
Transient Capture 40 ns pulse width Select 20/50/100/200% ± 5% of full scale
Up to 40 transients above or below line voltage
Inrush Current 1 sec. to 5 min selectable 1 A to 1000 A ± 5% of full scale
Ohms/Continuity/ Ohms 500.0 Ω to 30.00 MΩ ± (0.6%+5)
Capacitance Capacitance 50.00 nF to 500.0 μF ± (2%+10)
Temperature ºC -100.0ºC to 400.0ºC ± (0.5%+5)
(with accessory) ºF -200.0ºF to 800.0ºF
Scope DC, AC, AC+DC, peak, Sampling rate: 25 MS/sec
peak-peak, Hz, duty cycle, Bandwidth:
phase, pulse width, Voltage BW (Channel 1) 20 MHz
crest factor Current BW (Channel 2) 15 kHz
Included Accessories Screen saves All functions 20 screens
TL224 test lead set, AC220 alligator clip set, Recording V/A/Hz, Power, Harmonics,
Ω/Cap, Temperature, Scope
4 min - 16 days selectable Select any two parameters
display mode in each
TP4 test probe set, BP120MH rechargeable
battery pack, BB120 shielded BNC adapter,
PM8907 line adapter/charger, i400s AC current
clamp, AB200 alligator clip set,
Battery life: Rechargeable Ni-MH pack (charger included), 6 hrs typical (continuous)
TP1 test probe set, C120 hand carrying case,
Shock & Vibration: Mil 28800E, Type 3, Class III, Style B.
OC4USB interface cable, SW43W FlukeView Operating temperature: 0°C to 50°C; Case: IP51 (dust, drip, waterproof)
software, VPS 40 voltage probe, Fluke 61 IR Size (HxWxD): 232 mm x 115 mm x 50 mm; Weight: 1.1 kg
thermometer, user and application manual. Three Years Warranty

Ordening information
Fluke 43B Power Quality Analyzer Recommended Accessories
(single-phase)

i2000flex i1000s 80TK PAC91


See page 114 See page 114 See page 116 See page 76
81
430 Series Three-phase
Power Quality Analyzers

Pinpoint power quality problems faster, safer and


in greater detail
The Fluke 435 and 434 three-phase power AutoTrend - Quickly see the trend
quality analyzers help you locate, predict, Unique AutoTrend gives you fast insight into
prevent and troubleshoot problems in changes over time. Every displayed reading
power distribution systems. These easy-to- is automatically and continuously recorded
use handheld tools have many innovative without having to set up threshold levels
features to give you the details to pinpoint or interval times, or having to manually
problems faster and safer. start the process. You can quickly view
trends in voltage, current, frequency, power,
• Complete three-phase troubleshooting harmonics or flicker on all three phases plus
tool: measures virtually every power neutral. And you can analyze the trends
system parameter: voltage, current, using the cursors and zoom function – even
frequency, power, power consumption while background recording continues.
(energy), unbalance and flicker, harmonics
and inter-harmonics. Captures events like SystemMonitor - Check performance
dips and swells, transients, interruptions against EN50160 with ease
and rapid voltage changes. With a single push of a button, the unique
• The Fluke 435 features 0.1 percent voltage System-Monitor gives you an overview of
Fluke 435
accuracy making it fully compliant with power system performance, and checks the
the IEC 61000-4-30 Class A standard compliance of incoming power to EN50160
• Logger: record the detail you need. limits or to your own custom specifications.
Detailed, user-configurable long-time The overview is shown on a single screen,
recording gives you the MIN, MAX and AVG with color-coded bars clearly indicating
readings of up to 100 parameters on all which parameters fall outside the limits.
4 phases with selectable averaging time
down to 0.5 seconds. Enough memory is
available to record 400 parameters with 1
minute resolution for up to a month.
• Four channels: simultaneously measures
voltage and current on all three phases
and neutral.
• AutoScaling: easier trend analysis with
automatic scaling of the vertical axis you
will always use the full display to view the
waveforms.
• Automatic transient display: captures up to
40 dips, swells, interruptions or transients
automatically.
Fluke 434 • Meets the stringent 600 V CAT IV,
1000 V CAT III safety standard required for
measurements at the service entrance.
True RMS • Rugged, handheld instrument operates
for more than 7 hours on included
On all inputs
rechargeable NiMH battery pack. Menu-
driven interface simplifies operation.
• Extensive data analysis possibilities.
Cursors and zoom can be used ‘live’ while
taking the measurements, or ‘offline’ on
stored measurement data. The stored
measurements can also be transferred to a
PC with FlukeView software (included with
Fluke 435 and 434).
• The Fluke 435 comes with Power Log
software to analyse recorded data and to
create reports.
• Complete package includes everything to
get started: 4 current clamps, 4 flex clamps
with Fluke 435, 5 voltage test leads and
clips, line adapter/battery charger and hard
case.
• Complies with IEC 61000-4-30
measurement standards.
The System-Monitor overview screen gives instant insight
into whether the voltage, harmonics, flicker, frequency and
the number of dips and swells fall outside the set limits.
A detailed list is given of all events falling outside the set
limits.

82 AutoTrend automatically records all displayed parameters


in the background.
430 Series Three-phase
Power Quality Analyzers

Logging function allows you to customize measurement Measure and record power (W), VA and VARs. Track harmonics up to the 50th, and measure and record
selections and provides instantaneous analysis of user- The 434 and 435 add the ability to record energy THD in accordance with IEC61000-4-7 requirements
selectable parameters. consumption.

Specifications
(Check the Fluke web for detailed specifications)

Inputs Number of inputs 4 voltage and current (3 phases + neutral)


Maximum input voltage 1000 Vrms (6kV Peak)
Maximum sampling speed 200 kS/s on each channel simultaneously

Volt/Amps/Hertz Vrms (AC+DC) 1…1000 V ± 0.1% of nominal voltage


Vpk 1…1400 V 5% of Vnom
Crest factor, voltage 1.0 ... > 2.8 ± 5%
Arms (AC+DC) 0…20,000 A ± 0.5% ± 5 counts
Apeak 0 - 5500 A 5%
Crest factor, A 1 … 10 ± 5%
Fluke 435 with flex clamps Hz 50Hz nominal 42.50 ... 57.50 Hz ± 0.01Hz
Dips and swells Vrms (AC+DC) 2 0.0% ….100% of Vnom ± 0.2% of nominal voltage
Arms (AC+DC) 2 0 … 20,000 A1 ± 1% ± 5 counts
Harmonics Harmonic (interharmonic) (n) DC, 1..50; (Off, 1..49) measured according to IEC 61000-4-7
Vrms 0.0 … 1000 V ± 0.05% of nominal voltage
Arms 0.0 … 4000 mV x clamp scaling ± 5% ± 5 counts
Included Accessories Watts depends clamp scaling and ± 5% ± n x 2% or reading,
Fluke 435/434: Hard carrying case C430 (434)/ voltage ± 10 counts
DC voltage 0.0 … 1000 V ± 0.2% of nominal voltage
Water-tight hard case with rollers C435 (435) THD 0.0 … 100.0 % ± 2.5% V and A (± 5% Watt)
4 current clamps, i400s, CAT IV 600 V Hz 0 … 3500 Hz ± 1 Hz
(Fluke 434) Phase angle -360º ... +360º ± n x 1.5º
Power and Energy Watt, VA, VAR 1.0 … 20.00 MVA1 ± 1% ± counts
4 current clamps, i430-Flex-4pk, CAT IV kWh, kVAh, kVARh 00.00 …200.0 GVAh1 ± 1.5% ± 10 counts
600 V (Fluke 435) Power Factor/ Cos ij / DPF 0…1 ± 0.03
5 Test leads, 4 black, 1 green Flicker Pst (1min), Pst, Plt, PF5 0.00 … 20.00 ±5%
Unbalance Volts 0.0 … 5.0% ± 0.5%
Battery Charger Eliminator, BC430 Current 0.0 … 20% ± 1%
FlukeView Software, SW43W Transient capture Volts ± 6000 V ± 2.5% of Vrms
Power Log Software (435) Minimum detect duration 5 μs (200 kS/s sampling)
Inrush mode Arms (AC+DC) 0.000 … 20.00 kA 1
± 1% of meas ± 5 counts
Optical Cable for USB, OC4USB
Inrush duration (selectable) 7.5 s … 30 min ± 20 ms (Fnom = 50 Hz)
Color localization set, WC100 AutoTrend recording Sampling 5 readings/sec continous sampling per channel
Getting Started printed Memory 1800 min, max and avg points for each reading
User Manual (CD-ROM) Recording time Up to 450 days
Zoom Up to 12x horizontal zoom
Basic versions: Excl. current clamps Memory Screens & data 50, shared memory divided between logging, screens and data sets
Standards Measurement methods used IEC61000-4-30 class A; EN50160; IEC 61000-4-15; IEC 61000-4-7

Ordering information
Fluke 435/Basic Power Quality Analyzer 1
depending clamp scaling
(three phase) 2
Value is measured over 1 cycle, commencing at a fundamental zero crossing, and refreshed each half-cycle

Fluke 435 Power Quality Analyzer


(three phase) Battery life: > 7 hours with rechargeable NiMH (installed); Battery charging time: 4 hours typical
Safety: EN61010-1 (2nd edition) pollution degree 2; 1000 V CAT III / 600 V CAT IV
Fluke 434/Basic Power Quality Analyzer Case: Rugged, shock proof with integrated protective holster, IP51 (drip and dust proof)
(three phase) Shock: 30 g; Vibration: 3g according to MIL-PRF-28800F Class 2
Fluke 434 Power Quality Analyzer Operating temperature: 0°C to +50°C
Size (HxWxD): 256 mm x 169 mm x 64 mm; Weight: 1.1 kg
(three phase) Three Years Warranty
Fluke 434/LOG Logger Upgrade Kit: Adds
the Logger Function of
the 435 to the 434 Recommended Accessories
OC4USB Serial Interface Adapter/
Cable (USB)
PM9080 Serial Interface Adapter/
Cable (RS232)
GPS430 GPS sync module
for 430 Series GPS430 i430-flex-4pk i5sPQ3 i1000s OC4USB
See page 88 See page 88 See page 144 See page 76
83
See page 88 for power quality current clamps
1735 Power Logger
Performs electrical load studies, energy
consumption testing, and general power
quality logging
The Fluke 1735 Power Logger is the ideal • Record power and associated
tool for electricians and maintenance parameters for up to 45 days
technicians for conducting energy • Monitor maximum power demand over
studies and basic power quality logging. user-defined averaging periods
The 1735 is easy to set up with its color • Prove the benefit of efficiency
display and four included flexible current improvements with energy
probes. consumption tests
The 1735 logs most electrical power • Measure harmonic distortion caused by
parameters, harmonics and captures electronic loads
Fluke 1735
voltage events. View graphs and generate • Improve reliability by capturing voltage
reports with the included Fluke Power dips and swells from load switching
Log software. • Confirm instrument setup easily with
color display of waveforms and trends

View recorded data in simple graphs and Conduct load studies


tables with Fluke Power Log software. for up to 45 days and
view saved data Access voltage and
on-screen or on a current harmonics
computer. up to the 50th.

Quantify energy
consumption quickly
on-screen or log to Capture voltage events
memory for extended using user-defined
periods. thresholds.

Customize the report generator to easily


generate professional looking reports. Specifications
(Check the Fluke web for detailed specifications)

Volts rms V-rms wye measurement ranges:


57 V/66 V/110 V/120 V/127 V/220 V/230 V/240 V/260 V/277 V/347 V/380 V/
400 V/417 V/480 V AC
V-rms delta measurement ranges:
100 V/115 V/190 V/208 V/220 V/380 V/400 V/415 V/450 V/480 V/600 V/660 V/
690 V/720 V/830 V AC
Amps rms Flexi set measurement range: 15 A/150 A/3000 A rms (at sine)
Current clamp measurement range: 1 A/10 A
Frequency Measurement range: 46 Hz to 54 Hz and 56 Hz to 64 Hz
Harmonics and THD To 50th harmonic (< 50 % of nom)
Power measurement Measuring range: see V-rms and A-rms measurement ranges
(P - Active, S - Apparent, Q - Reactive, D - Distorting)
Energy Measurement (kWh, KVAh, kVARh) Measuring range: see V-rms and A-rms measurement rangeso
PF (Power factor) 0.000 to 1.000
Events Detection of voltage dips, voltage swells and voltage interruptions with a
10 ms resolution and measuring error of the half period sine wave of rms.

General
Memory 4 MB Flash memory, 3.5 MB for measuring data
Sample rate 10.24 kHz
Line frequency 50 Hz or 60 Hz, user-selectable, with automatic synchronization

Display: VGA Graphic Color transmissive displays Power supply: NiMH battery-pack, with AC adapter
320 x 240 pixels with additional background lighting (15 V to 20 V/0.8 A)
and adjustable contrast, text and graphics in color Battery Life: Typical > 16 hours without backlight and
Included Accessories Interface: RS-232 SUB-D socket; 115.2 k Baud, > 6 hours with backlight high
8 data bits, no parity, 1 stop bit, firmware updates are Operating temperature: 0°C to +40°C
FS17XX 4-phase flexible current clamp set, possible with the RS-232 interface (9-pole extension Size (HxWxD): 240 mm x 180 mm x 110 mm
VL1735/1745 voltage lead set, Power Log cable) Weight: 1.7 kg, including battery
Housing: IP65; EN60529 (refers only to the main Two Year Warranty
software, color localization set, PC interface housing without the battery compartment)
cable, international ac adapter, BC1735 battery
charger, soft carrying case, printed English
manual and multi-language manual on CD.

Ordering Information Recommended Accessories


Fluke 1735 Power Logger
See page 88 for power quality current clamps
84
1740 Series Three-Phase
Power Quality Loggers Memobox

Assess power quality and conduct long-term


studies with ease
Compact, rugged and reliable, the Fluke • Plug and play: Set up in minutes with
1740 Series three-phase power quality automatic current probe detection and
loggers are everyday instruments for powering
technicians who troubleshoot and • Installs inside the cabinet: Compact,
analyze power distribution systems. fully-insulated housing and accessories
Capable of simultaneously logging up fit easily in tight spaces next to live
to 500 parameters for up to 85 days and power
capturing events, the Fluke 1740 Series • Monitors power for the long-term:
helps uncover intermittent and hard-to- Data can be downloaded during
find power quality issues. There are three recording without interruption
models to choose from to meet your • Measure voltage with premium
basic or advanced power logging needs. accuracy: IEC61000-4-30 Class-A
Fluke 1743 compliant voltage accuracy (0.1%)
Fluke 1743: IP65 waterproof monitor • Quickly validate quality of power:
Fluke 1744
for logging the most common power Assess power quality according to
parameters including V, A, W, VA, VAR, PF, EN50160 power quality standard with
energy, flicker, voltage events and THD. statistical overview

Fluke 1744: Includes the same features


as the Fluke 1743. In addition to common
power parameters, the Fluke 1744 also
measures voltage and current harmonics,
interharmonics, mains signaling,
unbalance, and frequency.
Fluke 1745

Fluke 1745: Advanced IP50 power quality


logger with the same measurement
capability as the 1744, plus real-time LCD,
five hour UPS.

The included PQ Log software helps you


Specifications
to quickly identify the root cause of a (Check the Fluke web for detailed specifications)
disturbance.
1745 1744 1743
Measurement of common power parameters: V, A, W, O O O
VA, VAR, PF, energy, flicker, voltage events (dips, swells,
Included Accessories interruptions), and THD
Fluke 1743/1744/1745: FS17XX flexible current Measurement of voltage and current harmonics to the O O
50th, unbalance, frequency and mains signaling
clamp set , VL1735/1745 voltage lead set (1745 Dust/water resistance IP 50 IP 65 waterproof
only), Power Log software, RS232 interface Display LED + LCD LED LED
cable and RS232-USB adapter, 4 black dolphin Memory 8 MB 8 MB 8 MB
clips, WC17XX color localization set, carrying UPS ride-through > 5 hrs 3s 3s
bag, test certificate with measurement values, EN 50160 O O O
printed English manual and multi-language
manual on CD.
Basic models: Excl. current clamps FS17XX

Ordering Information Power supply: 88 V … 660 V AC Size: Fluke 1745: 282 mm x 216 mm x 74 mm;
Safety: IEC/EN 61010-1 600 V CAT III, 300 V Fluke 1743/44: 170 mm x 125 mm x 55 mm
Fluke 1743 Basic Power Quality Logger CAT IV, pollution degree 2, double insulation Weight: Fluke 1745 – approx. 3 kg;
Memobox Housing: Fully insulated housing and accessories Fluke 1743/44: approx. 2 kg
Operating temperature: 0 °C to 35°C Two Year Warranty
Fluke 1743 Power Quality Logger Interface: RS 232, 9600 ... 115 000 Baud, automatic
Memobox Baud rate selection, 3-wire communication
Fluke 1744 Basic Power Quality Logger
Memobox
Fluke 1744 Power Quality Logger
Memobox
Fluke 1745 Power Quality Logger
Memobox

See page 88 for power quality current clamps


85
1750 Three-Phase Power
Recorder

New Never miss capturing a disturbance

With its exclusive threshold-free • Captures everything: Cross-channel


measurement system, the Fluke 1750 and current triggering capture every
Power Recorder measurement, on every channel, every
captures every measurement, every event, time.
on every cycle, all the time. Outstanding • Intuitive PC software: Easily analyze
accuracy and resolution provide complete data and generate reports. Automated
visibility into your installation or EN50160 reporting and compliance.
On all inputs distribution system. • Plug and play: Set up in minutes with
selfidentifying current probes and
• Power quality that meets the standard: single-lead voltage connections.
All measurements comply with • No need to reconnect wires: Swap
IEC61000-4-30 standards for correct channels internally with the wireless
evaluation of all measured values PDA or PC when connections are not
including voltage, current, power, correct.
harmonics, flicker etc. • Measure every parameter: Voltage and
• Quick and reliable configuration: PDA current on three phases, neutral, and
wireless “front panel interface” provides ground.
the ability to verify setup without a • 5 MHz, 8000 Vpk waveform capture:
laptop along with a window into what Get a detailed picture of even the
the instrument is recording, even in shortest events.
awkward test locations. • Quickly retrieve data: With included SD
• Threshold-free setup: Apply thresholds memory card or via the 100BaseT high-
after data is collected with Fluke Power speed Ethernetv connection
Analyzer Software so there is no need to
worry about missed information due to
incorrect set-up.

View measurements real time with wireless PDA interface

Specifications
(Check the Fluke web for detailed specifications)

Power quality measurement standards


Conformance IEC 61999-1-4 Class 1, IEC 61000-4-30, IEEE519, IEEE1159, IEEE1459 and EN50160
Clock/calendar Leap years, 24-hour clock
Real-time clock accuracy Not more than ± 1 s/day
Internal memory capacity for data At least 1 GB
Maximum recording period At least 31 days
Measurement time control Automatic
Maximum number of events Limited only by the size of the internal memory
Power requirements 100 to 240 V rms ± 10 %, 47-63 Hz, 40 W
Operating time during interruptions (internal UPS operation) 5 minutes per interruption, 60 minutes total operating time without recharging

Safety: EN 61010-1 2nd Edition; 2000


Weight: 6.3 kg
Size (H x W x D): 215 x 310 x 35 mm
Included Accessories One Year Warranty
PDA and charger power plug adapters, 4 - 400
A current probes (3140R), 5 test leads and
clips, SD memory card., Fluke Power View and
Fluke Power Analyze software, Recommended Accessories
power cord with international plug set,
Ethernet cable, color localization set, soft
carrying case, Printed Getting Started manual, Model Description
CD with software and users manual PDF 3110-PR Flexible Current Transformer (2 A - 100 A)
3210-PR Flexible Current Transformer (20 A – 1000 A)
Basic model: excl. 4 current probes (3140R) 3310-PR Flexible Current Transformer (100 A - 5000 A)
3312-PR Flexible Current Transformer (100 A – 5000 A)
3005-PR Clamp-on Current Transformer (0.01 A – 5 A)
Ordering Information 3014-PR Clamp-on Current Transformer (0.1 A – 40 A)
3140R Clamp-on Current Transformer (2 A – 400 A)
Fluke 1750/B Three-Phase Basic Power FLUKE-1750/SEAT-L Fluke Power Analyze – Additional SEAT LICENSE
Recorder FLUKE-1750/SITE-L Fluke Power Analyze – Additional SITE LICENSE
Fluke 1750 Three-Phase Power FLUKE-1750/CASE Hard Case
CS1750 Soft Case
Recorder
HP IPAQ 2490 Additional Wireless Interface PDA
FLUKE-1750/MC Additional 512 MB SD Memory Card
86
1760 Three-Phase Power
Quality Recorder Topas

Class-A compliance for the most demanding


power quality tests
The Fluke 1760 Three-Phase Power • GPS time synchronization: Correlate
Quality Recorder is fully compliant to data with events or datasets from other
IEC 61000-4-30 Class-A, for advanced instruments with precision
power quality analysis and consistent • Uninterrupted power supply
compliance testing. Designed for analysis (40 minutes): Never miss important
of utility and industrial power distribution events - even record the beginning and
systems, in medium and low-voltage end of interruptions and outages
networks, the Fluke 1760 provides the • 10 MHz, 6000 Vpk waveform capture:
flexibility to customize thresholds, Get a detailed picture of even the
algorithms, and measurement selections. shortest event
Fluke 1760 It has 8 input channels (4 currents/4 • 2 GB data memory: Enables detailed,
voltages or 8 voltages), and captures the simultaneous recording of numerous
most comprehensive details on user power parameters for long periods of
selectable parameters. time
• Includes Comprehensive software:
Provides trend diagrams for root cause
analysis, statistical summaries, report
writing and real-time data monitoring
in the online mode

Features
(Check the Fluke web for detailed specifications)

1760 Basic 1760TR Basic 1760 1760TR


Power quality statistics according to EN50160 O O O O
Voltage event list (dips, swells and interruptions) O O O O
Continuous recording of:
Voltage O O O O
Current O O O O
Power P, Q, S O O O O
Power factor O O O O
kWh O O O O
Flicker O O O O
Unbalance O O O O
Frequency O O O O
Voltage and current harmonics to the 50th/ O O O O
Interharmonics
THD O O O O
Mains signaling O O O O
Triggered recordings O O O O
Online mode (Oscilloscope, transients and events) O O O O
Fast transient analysis up to 10 MHz O O
4 voltage probes O O
4 dual-range flexible current probes (1000 A / 200 A ac) O O
GPS time sync receiver O O
Memory 2 GB Flash memory
The included PQ Analyze software
provides a detailed overview of several
power quality parameters on one
dashboard according to the EN50160
power quality standard.
Power supply: 83 V to 264 V, 45 to 65 Hz Operating temperature: 0 °C to 35°C
Battery pack: NIMH, 7.2 V, 2.7 Ah (up to 40 minutes Interfaces: Ethernet (100 MB/s), RS-232, external
back-up power supply) modem via RS-232
Safety: 600V CAT IV/1000V CAT III Size (HxWxD): 325 mm x 300 mm x 65 mm
(Rated for use at the service entrance) Weight: Approxiamtely 4.9 kg
Included Accessories Housing: Fully insulated robust plastic housing Two Year Warranty
4 x TPS Flex 24 flexible current probe, 4 x
TPS VoltProbe 6000V, 2 GB internal flash
memory, ST1760 standard Ethernet cable,
RS232 interface cable and RS232-USB adapter, Recommended Accessories
CS1760 crossover Ethernet cable, 1 mains (Check the Fluke web for complete accessory list)
cable, PC software on CD-ROM, WC17xx color
localization set, GPS-time sync (1760TR only) Model Description
CS 1750/1760 carrying bag, hardware and • TPS VOLTPROBE 10 V 10 V Voltage Probes (Range: 0.1 V to 17 V)
• TPS VOLTPROBE 100 V 100 V Voltage Probes (Range: 1 V to 170 V)
software manual • TPS VOLTPROBE 400 V 400 V Voltage Probes (Range: 4 V to 680 V)
Basic models: Excl. current clamps TPS flex 24 • TPS VOLTPROBE 600 V 600 V Voltage Probes (Range: 10 V to 1000 V)
• TPS VOLTPROBE 1 KV 1000 V Voltage Probes (Range: 10 V to 1700 V)
Ordering Information • TPS FLEX 18 Flexible Current Probe (Range: 1 A to 100 A / 5 A to 500 A)
• TPS FLEX 24 Flexible Current Probe (Range: 2 A to 200 A / 10 A to 1000 A)
Fluke 1760 Basic Power Quality Recorder • TPS FLEX 36 Flexible Current Probe (Range: 30 A to 3000 A / 60 A to 6000 A)
Topas • TPS CLAMP 10 A / 1 A Clip-on Current Transformer (Range: 0.01 A to 1 A / 0.1 A to 10 A)
Fluke 1760TR Basic Power Quality Recorder • TPS CLAMP 50 A / 5A Clip-on Current Transformer (Range: 0.05 A to 5 A / 0.5 A to 50 A)
• TPS CLAMP 200 A / 20 A Clip-on Current Transformer (Range: 0.2 A to 20 A / 2 A to 200 A)
Topas
• TPS SHUNT 20 MA 20 mA ac/dc Shunt (Range: 0 to 55 mA)
Fluke 1760 Power Quality Recorder • TPS SHUNT 5 A 5 A ac/dc Shunt (Range: 0 to 10 A)
Topas 87
Fluke 1760TR Power Quality Recorder
Topas
88
Fluke model number i1A/10A i1A/10A i5A/50A i5A/50A i20A/200A i20A/200A FS17xx FS17xx IP65 i3000 flex ... 4PK i400s i430 ... flex ... 4PK i5sPQ3
CLAMP PQ3 CLAMP PQ4 CLAMP PQ3 CLAMP PQ4 CLAMP PQ3 CLAMP PQ4

Descript ion 3 ... phase 4 ... phase 3 ... phase 4 ... phase 3 ... phase 4 ... phase 4 Phase flexiset, 4 Phase flexiset, 4 ... phase Single phase 4 ... phase 3 ... phase 5A
1A/10A Mini 1A/10A Mini 5A/50A Mini 5A/50A Mini 20A/200A 20A/2000A IP41 IP65 3000A Flexible 400A current 3000A Current clamp
current clamp current clamp current clamp current clamp Mini current Mini current current clamp clamp Flexible set
set set set set clamp set clamp set set (4 required) current clamp
set
Old Fluke model # CURRENT MBX CLAMP MBX CLAMP MBX CLAMP MBX CLAMP MBX CLAMP MBX Lem Flex MBX Lem Flex
CLMAPS 1A 1A/10A+N 5A/50A 5A/50A+N 20A/200A 20/2000A+N (15/150/3000) (15/150/3000)
(EPO450A) (EPO451A) (EPO452A) (EPO453A) (EPO455A) (EPO456A) (EP0404A) (EP0404A)

Fluke 1735 O O O O O O O O
Fluke 174X O O O O O O O O
Fluke 43X O O O O
Nominal current range(s) 1A 1A 5A 5A 20 A 20 A 15A 150A 1500A 15A 150A 1500A 30 A 40 A 3000 A 5A
10 A AC 10 A AC 50 A AC 50 A AC 200 A AC 200 A AC 3000A AC 3000A AC 300 A 400 A
3000 A
Cont. AC current range 10 mA ... 1 A 10 mA ... 1 A 50 mA ... 5 A 50 mA ... 5A 200 mA ... 200 mA ... 450mA … 15A 450mA … 15A 1 A ... 30 A 0.5 A ... 40 A 30 A ... 3000 A 0.01 A ... 6 A
100 mA ... 10 A 100 mA ... 500 mA ... 500 mA ... 20 A 20 A 600mA… 150A 600mA… 150A 1 A ... 300 A 5 A ... 400 A
10 A 50 A 50 A 2 A ... 200 A 2 A ... 200 A 6A… 1500A 6A… 1500A 1 A ... 2400 A
12A… 3000A 12A… 3000A

Highest current 20 A 20 A 100 A 100 A 300 A 300 A 3300 A 3300 A 4000 A 1000 A 100 kA 70 A
Lowest measurable current 10 mA 10 mA 50 mA 50 mA 200 mA 200 mA 450 mA 450 mA 1A 0.5 A 30 A 10 mA
Basic accuracy (48 ... 65 Hz) 1) 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 2%+2% position 2%+2% position 2% + 2 A 2% + 0.15 A 1% 1%
influence influence
Usable frequency 40 Hz ... 10 kHz 40 Hz ... 10 40 Hz ... 10 40 Hz ... 10 40 Hz ... 10 40 Hz ... 10 40Hz …5kHz 40Hz …5kHz 10 Hz ... 100 45 Hz ... 3 kHz 10 Hz ... 7 kHz 40 Hz ... 5 kHz
kHz kHz kHz kHz kHz kHz
Requires battery O
Flex head length 61 cm 61 cm Clamp 61 cm Clamp
opening: opening:
32 mm 15 mm
Output level(s) 75 mV/A 75 mV/A 15 mV/A 15 mV/A 3.75 mV/A 3.75 mV/A 0.1 mV/A 0.1 mV/A 10 mV/A 10 mV/A 0.085 mV/A 400 mV/A
1 mV/A 1 mV/A @50 Hz
0.1 mV/A
Output cable (m) 2 2 2 2 2 2 2 2 2.1 2.5 2.5 2.5
Safety rating CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 1000 V CAT III 1000 V CAT III 600 V CAT III 1000 V CAT III 1000 V CAT III 600 V
CAT IV 600V CAT IV 600V CAT IV 600 V CAT IV 600 V

Connection One connector One connector One connector One connector One connector One connector One connector One connector 4 x BNC 4 x BNC 4 x BNC 3 x BNC

BNC to banana adapters included n/a n/a n/a n/a n/a n/a n/a n/a O

1
Basic accuracy: % reading plus floorspec.
n/a = not applicable
Power Quality Current Clamps

i3000 flex-4PK i400s i430-flex-4PK i5sPQ3


(4x i3000s flex24)
Norma 4000/5000
Power Analyzers

Reliable, highly accurate measurements for


the test & development of power electronics
The compact Fluke Norma Series The Series consists of the Fluke Norma
Power Analyzers provide the latest 4000 Three-Phase Power Analyzer and
measurement technology to assist the Fluke Norma 5000 Six-Phase Power
engineers with the development and Analyzer. These rugged analyzers provide
testing of motors, inverters, lighting, unmatched price performance for easy
power supplies, transformers and and reliable use in the field, or as a bench
automotive components. unit in laboratories and on test benches.

Based on a patented, high-bandwidth • Simple user interface ensures easy,


architecture, the instruments deliver intuitive operation
Fluke Norma Series Power Analyzers high-precision measurements of single • Unique user-configurable modular
or three-phase current and voltage, design
harmonics analysis, Fast Fourier • Simultaneous parallel acquisition of all
Transformation (FFT) analysis, as well as phases
calculations of power and other derived • Voltage, current and power harmonics
values. up to the 40th
• Includes FFT analysis, vector diagram
A unique user-configurable system display, recorder function, and Digital
design with plug-in power phases and Oscilloscope (DSO) mode
other optional modules provides the • User selectable average time – from
flexibility to meet a variety of application 15ms to 3600s
measurement requirements. Recorded • Expandable on-board memory for
data and waveforms can be viewed storage of measured values
clearly in the large color display and
easily downloaded to a PC for analysis
and report writing.
Fluke Norma 4000

Fast Fourier Digital Oscilloscop Vector Display Recorder function


Transformation (FFT) (DSO) mode
analysis

Specifications
Fluke Norma 5000 (Check the Fluke web for detailed specifications)

Fluke Norma 4000 Fluke Norma 5000


Number of Phases 1 or 3 3, 4 or 6
Weight Approx. 5 kg Approx. 7 kg
Size (HxWxD) 15 cm x 23.7 cm x 31.5 cm 15 cm x 44.7 cm x 31.5 cm
On-board Printer No Yes (optional)
Display Color, 5.7“ / 144 mm - 320 x 240 pixel
Bandwidth dc to 3 MHz or dc to 10MHz depending on input module
Basic Accuracy 0.2%, 0.1% or 0.03% depending on input modules
Sampling Rate 0.33 MHz or 1 MHz depending on input modules
Voltage Input Range 0.3 V to 1000 V
Current Input Range (direct, not via shunt) 0.03 mA – 20 A depending on input module
Memory for Configurations 4 MB, expandable to 128 MB
Memory for Settings 0.5 MB
Fast Fourier Transformation (FFT) To the 40th harmonic
RS232 Interface Standard
PI1 Process Interface (8 analog/impulse inputs and Optional
4 analog outputs)
IEEE 488.2 /GPIB Interface (1 MBit/s Ethernet / Optional
10 MBit/s or 100 Mbit/s)
Fluke NormaView PC Software (for data download, Standard
Included Accessories analysis & report writing)
Power Supply Cable, RS232 Interface and USB
adaptor for Data Download, Fluke NormaView
PC Software, User’s Manual, Test Certificate,
and Calibration Values.

Ordering Information Operating temperature: Housing: Solid metal case


+ 5 °C to 35 °C Safety: EN 61010-1 / 2nd Edition, 1000 V CAT II
Fluke Norma 4000 Three-Phase High
Storage temperature: (600 V CAT III)
Precision Power Analyzer - 20 °C to 50 °C Two Year Warranty
Fluke Norma 5000 Six-Phase High Precision Climatic class: KYG DIN 40040, maximum
Power Analyzer 85% relative humidity, non-condensing.

89
Norma 4000/5000
Power Analyzer Accessories

Power Phases
The Fluke Norma 4000 Power Analyzer Each plug-in power phase consists of
can be equipped with up to three power a voltage and a current measurement
phases and the Fluke Norma 5000 Power channel. Each measuring channel is
Analyzer can be equipped with up to six available for each basic unit.
power phases. Users can select the power
phase best suited for their application.
Fluke Norma 4000 (rear view) Specifications vary depending on the model
of the power phase.

Power Phase Overview

3024770 3024812 3024820 3024835


Channel PP42 PP50 PP54 PP64
Accuracy 0.2% 0.1% 0.03%
(0.1% rd + 0.1% rg) 0.05% rd + 0.05% rg (0.02% rg + 0.01% rg)
Current range 20 A 10 A 10 A 10 A
Sampling rate 341 kHz 1 MHz 341 kHz 341 kHz
Bandwidth 3 MHz 10 MHz 3 MHz 3 MHz

Fluke Norma 5000 (rear view)

Shunts

The input modules can take up to 10 A


or 20 A directly or measure current via
wideband precision shunts. The available
range of shunts enables measurements up
to 1500 A and can be used in conjunction
Optional shunts for Fluke Norma Series Power
with all of the available input modules.
Analyzers

3024677 32 A Planar Shunt


3024689 Cables for 32 A Planar Shunt
3024886 10 A Triaxial Shunt with Cables
(0.333 ., 0 to 0.5 MHz)
3024899 30 A Triaxial Shunt with Cables
(0.010 ., 0 to 0.5 MHz)
3024847 100 A Shunt with Cables (0.001 Ω, 0 to 0.5 MHz)
3024858 150 A Shunt with Cables (0.5 mΩ, 0 to 0.5 MHz)
3024864 300 A Shunt with Cables (0.1 mΩ, 0 to 1 MHz) 32 A Planar Shunt
3024873 500 A Shunt with Cables (0.1 mΩ, 0 to 0.2 MHz)
3024692 LG Shunt Cables for High Current Shunts

Cables & Adaptors


3024661 Measurement Cable Set (for one power phase)
3024704 Fluke Norma WYE Adaptor (external accessory
box)

Printer Accessories
3024650 Printer Cable for Fluke Norma 5000
(RS232-Centronics)

All accessories have a


two-year warranty.

90
Field Calibrators

Fluke process calibration tools include a full range of calibrators and


troubleshooting tools for instrument technicians working in the process
industries. The range of process calibrators include: Documenting
Process Calibrators, Multifunction Process Calibrators, single function
and multifunction temperature calibrators, a variety of mA loop
calibrators and a range of intrinsically safe products.

91
92
Multifunction Process
Documenting Process Calibators Temperature Calibrators Pressure Calibrators Loop Calibrators ProcessMeters
Calibrator

Model 744 743B 741B 725/725Ex 726 724 714 712 718/718Ex 717 719 715 707/707Ex 771 772 773 705 789 787
Measure
Voltage DC 300 V 300 V 300 V 30 V 30V 30 V 75 mV 10 V 28 V 30 V 28 V 1000 V 1000 V
Voltage AC (true RMS) 300 V 300 V 300 V 1000 V 1000 V
Resistance 11 kΩ 11 kΩ 11 kΩ 3200 Ω 4000 Ω 3200 Ω 3200 Ω 40 MΩ 40 MΩ
Current DC 110 mA 110 mA 110 mA 24 mA 24 mA 24 mA 24 mA 24 mA 24 mA 24 mA 24 mA 100 mA 100 mA 100 mA 24 mA 30 mA, 30 mA, 1A
1A
Current AC O O
Frequency 50 kHz 50 kHz 50 kHz 10 kHz 15 kHz 20 kHz 20 kHz
Pressure O1 O1 O1 O1 O1 68,9 mbar 68,9 mbar 2 bar to
to 20 bar / to 345 bar2 7 bar2
2 to 7 bar2
Temperature: RTD types 8 8 8 7 8 7 7
Temperature: TC types 11 11 11 12 12 12 9
Source/Simulate
Voltage DC 15 V 15 V 15 V 10 V 20 V 10 V 75 mV 10 V 10 V
Resistance 11 kΩ 11 kΩ 11 kΩ 3200 Ω 4000 Ω 3200 Ω 3200 Ω
mA DC/% scale 22 mA 22 mA 22 mA 24 mA 24 mA O 24 mA 24 mA 24 mA 24 mA 24 mA 24 mA 24 mA
mA source; auto step, auto ramp O O O O O O O O O O O O
Frequency 50 kHz 50 kHz 50 kHz 10 kHz 15 kHz
Temperature: RTD types 8 8 8 7 8 7 7
Temperature: TC types 11 11 11 10 10 10 9

Record
Min/Max O O O O O O O O
Hold O O O O O O O O O
As Found/As Left results O O O
Log data O O
Upload data to PC O O O
Remote operation O/- O
Features
Loop supply 24 V 24 V 24 V 24 V/12 V 24 V 24 V 24 V/- 24 V 24 V 24 V 24 V 24 V 24 V 24 V 24 V
Hart communication O
Integrated hand pressure pump O
Electric Pump O
Intrinsically safe (ATEX) 725Ex 718Ex 707Ex
NIST traceable certification O O O O O O O O O O O O O O
Warranty in years 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3
See catalog page 93 93 93 94 94 95 96 96 98 98 98 99 99 100 100 100 99 101 101
Selection Guide
Field Calibrator

1
Fluke 700 pressure modules required
2
Ranges for the internal sensor.
Ranges for use of Fluke 700 pressure modules, see page 102.
740 Series Documenting
Process Calibrators

Calibrators as versatile as you are


The 740 series Documenting Process
Calibrators are rugged, handheld tools 743B: More memory, plus a PC
for the calibration and troubleshooting of interface and data logging
process control instrumentation. These The 743B has all the capabilities of
calibrators: the 741B plus a PC interface that lets
• Calibrate temperature, pressure, you download procedures, lists, and
voltage, current, resistance, and instructions created with software–or
frequency upload data for printing, archiving, and
• Simultaneously measure and source analysis. With its expanded memory, the
• Automatically capture calibration 743B can hold a full week of calibrations
results and procedures.
• Document procedures and results to
meet ISO 9000, EPA, FDA, OSHA, and 744: Get HART-ability
other government requirements The Fluke 744 offers all of the capabilities
• Measure/simulate eleven types of of the 743B, plus the ability to calibrate,
thermocouples and eight RTDs maintain, and troubleshoot HART
Fluke 743B
• Store up to 8,000 readings in data instrumentation with just one tool. This
logging mode (743B +744 only) rugged, reliable tool offers:
Fluke 744 • Protected against dirt, dust, and • Integrated HART communication
moisture; unaffected by vibration functions, permitting you to
• PC interface (743B +744 only) monitor, control, and calibrate HART
• Operates in English, French, German, instrumentation.
Italian, and Spanish • NiMH battery with 3500 mA hour life
• One and two-year calibration cycles and battery indicator.
• Four types of built-in automated
calibration procedures; linear
Instrumentation Management
transmitter, square root devices, one
and two-point limit switches Software
The Fluke 743B and 744 are compatible
with Fluke 700SW DPC/TRACK software
741B: A complete documenting
and with software from Cornerstone,
calibrator Fisher-Rosemont, Honeywell, Yokogawa,
Fluke 741B The 741B is the economical choice for Prime Technologies and On Time Support.
plants that don’t use PCs or that require
traditional paper forms. It has storage
capacity for a day’s calibration and
measurement data. When you’re back at
the shop, recall the data on-screen to fill
out calibration forms.

Included Accessories
Fluke 741B/743B: TL224 Industrial Test Leads Specifications
(2 sets), AC220 Test Clips (2 sets), TP220 Test
Probes (1 set), BP7217 Battery Pack, BC7217 (Check the Fluke web for detailed specifications)
Battery Charger, Instruction Manual, NIST
Function Measure Sourcing
Traceable calibration certificate and data,
Voltage DC 0.025% reading + 0.005% full scale 0.01% output + 0.005% full scale
three-year warranty, serial port cable (743B Current DC 0.01% reading + 0.015% full scale 0.01% output + 0.015% full scale
only), DPC/TRACK Sample Version with free PC Resistance 0.05% reading + 50mΩ 0.01% output + 40mΩ
communication utility software (743B only). Frequency 0.05% 0.01 %
Fluke 744: TL224 Industrial Test Leads Thermocouples 0.3ºC 0.2ºC
(2 sets), AC220 Test Clips (2 sets), TP220 Test RTDs 0.3ºC 0.1ºC
Probes (1 set), BP7235 NiMH Battery Pack, Pressure To 0.05% of full scale. See Pressure Module specifications.
BC7217 Battery Charger, serial port cable,
HART communications cable, DPC/TRACK Operating temperature: -10º C to 50º C Battery Replacement: Via snap-shut door
Sample Version with free PC communication Safety: CAT II 300V without opening calibrator; no tools required
Battery Life: Typically over eight hours Weight: 1.4 kg
utility software, Instruction Manual, HART Internal Battery Pack: NiCd, 7.2V, 1700 mAh Size (HxWxD): 236 mm x 130 mm x 61 mm
Users Manual, NIST Traceable calibration Three Year Warranty
certificate and data.

Ordering Information Recommended Accessories


Fluke 741B Documenting Process Calibrator
Fluke 743B Documenting Process Calibrator
Fluke 744 Documenting Process Calibrator
700SW DPC/Track Software

C789 TL220 80PK-8 80PK-25 700P27


See page 118 See page 110 See page 116 See page 116 See page 102
93
725/725Ex/726 Multifunction
Process Calibrators

More calibration power!


725/725Ex/726 Multifunction 726 Precision Multifunction
Process Calibrators Process Calibrator
• Two separate channels; measure, source Additional features:
and view process signals simultaneously • More precise measurement and
• Measure volts, mA, RTDs, calibration source performance,
thermocouples, frequency, and accuracies of 0.01%
resistance to test sensors and • Transmitter error% calculation
transmitters • Memory storage for up to 8 calibration
Fluke 725 • Source/simulate volts, mA, results
thermocouples, RTDs, frequency, and • Frequency totalizer and frequency
pressure to calibrate transmitters pulse train source mode for enhanced
• Measure or *source pressure using any flowmeter testing
of 29 Fluke 700Pxx Pressure Modules • HART mode inserts 250 ohm
• Source mA with simultaneous pressure resistor in mA measure and source
measurement to conduct valve and I/P for compatibility with HART
tests instrumentation
• Perform fast linearity tests with auto • Integrated pressure switch test allows
step and auto ramp features you to capture the set, reset and
Fluke 726 • Power transmitters during test using deadband of a switch
24 V loop supply and simultaneous mA • Custom RTD curves, add calibration
measurement constants for certified RTD probes for
• Store frequently-used test setups for enhanced temperature measurement
later use
• For 725Ex version see also page 106 and
107
Fluke 725Ex
*Pressure pump required
Features Unique 726 features are in bold
Specifications
Simultaneous Function Channel A Channel B Function Range or Type Resolution Accuracy Notes
Capability Measure or Source
24.000 mA DC M M or S Voltage 0 to 100 mV 0.01 mV 0.01% Max load, 1 mA
24.000 mA DC with M M or S 725: 0 to 10V (source) 0.001 V 0.02% Rdg + 2 LSD
24 V loop supply 0 to 20V (source) 0.001 V
100.00 mV DC M or S 725/726: 0 to 30V (measure) 0.001 V
mA 0 to 24 0.001 mA 0.01%; 0.02% Rdg Max load,
30.000V DC measure M M or S
+2 LSD 725/726: 1000Ω
20.000V DC Measure M or S 725Ex: 250Ω
10.000V DC Source mV -10.00 mV to +75.00 mV 0.01 mV 0.01%
20.000V DC Source
(TC terminals) 0.02% of range +
15 to 3200 Ohms M or S 1 LSD
5 to 4000 Ohms
Ohms 15Ω to 3200Ω 0.01Ω to 0.1Ω 0.10Ω to 1.0Ω
Thermocouple J, K, T, E, R, S, B, M, M or S 5Ω to 4000Ω 0.015%
L, U, N, XK, BP
Hz - CPM 2.0 to 1000 CPM 0.1 CPM ±0.05% Source;
RTD Cu 10, Ni120; Pt100 (392); M or S 1 to 1100 Hz 1 Hz ±0.05% 5V p-p
Pt100 (JIS); Pt100, 200, 500, 1000 1.0 to 10.0 kHz 0.1 kHz ±0.25% 1V - 20 V p-p
(385) 10.0 to 15.0 kHz 0.1 kHz ±0.05% squarewave,
Pressure (requires Fluke 700 PXX M M used as S -0.1 V offset
Modules) Loop Supply 725/726: 24 V DC N/A 10%
Frequency; 10 kHz; (15 kHz) M or S 725Ex: 12 V DC
T/C J, K, T, E, L, N, U, XK 0.1 ºC, 0.1 ºF to 0.7 ºC
to 0.2 ºC
T/C B, R, S, BP 1 ºC, 1 ºF to 1.7 ºC
M = Measure S = Source/Simulate
Unique 726 features are in bold to 1.2 ºC
725Ex: ATEX cerfified RTDs Cu (10), Ni 120 (672) 0.01 ºC to 0.15 ºC
(Ex ATEX II IG EEX 1a IIB 171°C) Pt 100, 200, 500, 1000 (385) 0.01 ºF
Pt 100 (3916),
Pt 100 (3926) 0.1 ºC, 0.1 ºF to 0.2 ºC

Maximum voltage: 30V Size (HxWxD): 200 mm x 96 mm x 47 mm


Operating temperature: 10°C to 55°C Weight: 0.65 kg
Included Accessories Safety: CSA C22.2 No. 1010.1:1992 Battery: Four AA alkaline batteries.
TL75 Test Leads, AC72 Test Clips, one pair EMC: EN50082-1:1992 and EN55022: Battery life: 25 hours typical; battery door
of stackable test leads, user’s Manuals on 1994 Class B Warranty: Three years
CD-ROM (725Ex also includes CCD control
drawing, Statement of Quality Assurance
Practices, NIST Traceable calibration
Recommended Accessories
certificate) (Not for hazardous zones)

Ordering Information
Fluke 725 Multifunction Process Calibrator
Fluke 725Ex Intrinsically Safe Multifunction
Process Calibrator
Fluke 726 Precision Multifunction Process C125 TL220 80PK-27 TPAK 700P27
See page 118 See page 110 See page 116 See page 120 See page 102
Calibrator
94
724 Temperature Calibrator

The temperature solution


The Fluke 724 Temperature Calibrator is • Execute remote tests with auto step and
a powerful yet easy-to-use calibrator. Use auto ramp
the measure and source functions to test • Power transmitters during test using
and calibrate almost any temperature loop power supply with simultaneous
instrument. mA measurement
• Easy to read dual display lets you view • Store frequently-used test setups for
input and output simultaneously later use
• Measure RTDs, thermocouples,
ohms, and volts to test sensors and
transmitters
• Source/simulate thermocouples, RTDs,
volts, and ohms to calibrate transmitters
• Perform fast linearity tests with 25% and
100% steps
Features
Simultaneous Function Channel A Channel B
Capability
24.000 mA DC M
24.000 mA DC with 24V loop M
supply
100.00 mV DC M or S
30.000V DC Measure M
20.000V DC Measure 10.000V M or S
DC Source
0 to 3200 Ohms M or S
Thermocouple J, K, T, E, R, S, B, M or S
L, U, N
RTD Ni120; Pt100 (3926); Pt100 M or S
Fluke 724 (JIS); Pt100, 200, 500, 1000 (385)

M = Measure S = Source/Simulate

Specifications
Function Range Resolution Accuracy Notes
Measure or Source
Voltage 0 to 100 mV 0.01 mV 0.02% Rdg + 2 LSD Max load, 1 mA

0 to 10V (source) 0.001 V


0 to 30V (measure) 0.001 V
mA (measure) 0 to 24 mA 0.001 mA 0.02% Rdg +2 LSD Max load,
1000Ω
mV -10.00 mV to +75.00 mV 0.01 mV 0.025% of range +
1 LSD
Resistance 0Ω to 3200Ω (measure) 0.01Ω to 0.1Ω 0.10Ω to 1.0Ω
15Ω to 3200Ω (source)
Loop Supply 24V DC N/A 10%
Thermocouples J, K, T, E, L, N, U 0.1 ºC to 0.7 ºC
Thermocouples B, R, S 1 ºC to 1.4 ºC
RTDs Ni120 (672) 0.1 ºC to 0.2 ºC
Pt 100, 200, 500, 1000 (385)
Pt 100 (3916)
Pt 100 (3926)

Maximum voltage: 30V Size (HxWxD): 200 mm x 96 mm x 47 mm


Operating temperature: -10°C to 55°C Weight: 0.65 kg
Safety: CSA C22.2 No. 1010.1:1992 Battery: Four AA alkaline batteries
Included Accessories EMC: EN50082-1:1992 and EN55022: Battery life: 25 hours typical; battery door
TL75 Test Leads, AC72 Test Clips, one pair of 1994 Class B Three Year Warranty
stackable test leads.

Ordering Information
Fluke 724 Temperature Calibrator
Recommended Accessories

C25 TL220 TL81A 80PK-25 80PK-3A


See page 118 See page 110 See page 109 See page 116 See page 116
95
712/714 Temperature Calibrators

The clear choice


The Fluke 710 Series Process Calibrators 712 RTD Calibrator
offer clear new choices in single-function • Measure temperature from RTD output
calibrators. Whatever you want to • Simulate RTD output
measure - temperature, pressure or basic • Rosemount pulsed RTD transmitter
electrical parameters - you’ll find one of compatible
these easy-to-carry handheld tools gives • Operates with seven types of RTDs
you exactly the functions you need. They • Measure additional RTDs using Ohms
combine the rugged, ready-for-action measurement function
package of the proven Fluke 80 Series • Simulate additional RTDs using Ohms
DMMs with the easy-to-use pushbutton source function
operation of the multifunction Fluke 740 • °F or °C selectable
Series Documenting Process Calibrators. • Four shrouded banana jacks
These calibrators are EMI tolerant,
dust and splash resistant, and have a 714 Thermocouple Calibrator
removable battery door for quick battery • Measure temperature from TC output
changes. • Simulate TC output
• Operable with nine types of
thermocouples
Fluke 714 • Calibrate linear TC transmitter with
mV source function
• Selectable °F or °C
• Thermocouple mini-jack termination
• Available as accessories; Fluke 700 TC1
and TC2 Thermocouple Mini-plug Kits

Fluke 712
Specifications
Model Function Range Resolution Accuracy Notes
Fluke 712 Measure/ -200 to 800ºC 0.1ºC, 0.1ºF 0.33ºC, 0.6ºF Pt; 100, 200, 500,
simulate RTD (Pt 100) (Pt 100) 1000 (385);
Pt 100 (3926);
Pt 100 (3916) JIS;
Ni 120 (672)
Measure/ 15 Ω to 3200 Ω 0.1 Ω 0.1 Ω to 1 Ω
simulate
Resistance
Fluke 714 Measure/ -200 to 1800ºC, 0.1–C or ºF 0.3ºC to 10 μV 9 TC types:
simulate depending on (1ºC or ºF; BRS) J K T E R S B per NIST
Thermocouple type (K, -200 to 175 and ITS-90, L U per
1370ºC) DIN 43710 and IPTS-68
Measure/ -10 to 75 mv 0.01 mV 0.025% +
simulate mV 1 count

Maximum voltage: 30 V Size (HxWxD): 201mm x 98 mm x 52 mm


Operating temperature: -10°C to 55°C Weight: 0.6kg
Included Accessories Safety: CSA C22.2 No. 1010.1:1992 Battery: 9V alkaline
EMC: EN50082-1:1992 and EN55022: Battery Life: 4 to 20 hours, typical, depending
Yellow Holster (H80M excl. TPAK), TL75 Test
1994 Class B on functions used
Leads and AC72 Alligator Clips (excluding Three Year Warranty
model 714), single 9V alkaline battery and
Instruction Sheet (14 languages)

Ordering Information
Fluke 712 RTD Calibrator
Fluke 714 Thermocouple Calibrator

Recommended Accessories

C25 C550 TL970 TL220 (714) 80PK-24 (714)


See page 118 See page 118 See page 109 See page 110 See page 116
96
9140 Series Field Metrology Wells
4180 Series Infrared Calibrators

Field Metrology Wells and infrared


calibration targets
9142, 9143, 9144 4180/4181 IR Calibrators
Field temperature calibration with True metrology solution for infrared
precision and speed Calibration
The Fluke 9140 series Field Metrology Now it’s easy to increase your IR
Wells extend high performance portable temperature measurement accuracy in
temperature calibration to the industrial the lab or the field with the new 4180/81
process environment by maximizing Precision Infrared Calibrators from Fluke’s
portability, speed, and functionality Hart Scientific division.
Fluke 9142/9143/9144
with little compromise to metrology
performance. Their accredited calibrations from Hart’s
IR laboratory help to ensure traceable,
Offering a broad temperature covered by consistent measurements accurate to
three models you can easily cover varied +0.25 ºC. Select from eight preconfigured
contact temperature probe workloads Fluke thermometer settings or set up your
between -25 ºC to 660 ºC. own.

They are quick to reach temperature set The large 152 mm (6 inch) target helps
points, yet they are stable, uniform, and eliminate errors. So whether you’re
accurate. These industrial temperature measuring from -15 ºC to 120 ºC (4180)
calibrators are perfect for performing or from 35 ºC to 500 ºC (4181) you’ll get
transmitter loop calibrations, comparison a 4:1 TUR.
calibrations, or simple checks of
thermocouple sensors. • High performance, designed for
industrial use
Adding the process option means there is • Guaranteed accuracy specifications
no need to carry additional tools into the • Excellent stability and uniformity
field. The optional built-in two-channel • Large 152 mm targets capture peripheral
readout measures resistance, voltage, and vision of IR thermometer
4–20 mA current with 24V loop power. • Portability and speed for field use -
including convenient bail handle
Fluke 4180/4181
• Lightweight, portable, and fast • Simulates individual IR thermometer
• Cool to –25 °C in 15 minutes and heat to emissivity settings
660 °C in 15 minutes • No difficult infrared calculations
• Built-in two-channel readout for PRT, • Fluke and Raytek thermometer
RTD, thermocouple, 4-20 mA current calibration points can be loaded directly
• On-board automation and into the calibrator for convenience
documentation • Calibrated in accredited infrared
• Metrology performance in accuracy, laboratory by Hart Scientific, the experts
stability, uniformity, and loading in temperature calibration
• At least 4 times more accurate than
Included Accessories most IR thermometers
914x: 9930 Interface-it Software, Report of • Calibration includes uncertainties from
Calibration, Test leads (P Version Only), surface heat loss and emissivity
6-pin DIN Connector for Reference Probe
(P Version Only)

Ordering Information
Fluke 4180 Precision Infrared
Calibrator, –15 °C to 120 °C
Fluke 4181 Precision Infrared Specifications
Calibrator, 35 °C to 500 °C
9142 9143 9144 4180 4181
Fluke 4180-CASE Carrying Case, 4180, 4181
Temp Range –25 °C to 150 °C 33 °C to 350 °C 50 °C to 660 °C –15 °C to 120 °C 35 °C to 500 °C
Fluke 4180-DCAS Carrying Case with wheels, Stability ±0.01 °C Full Range ±0.02 °C at 33 °C ±0.03 °C at 50 °C ±0.05 °C at 0 °C ±0.2 °C at 250 °C
4180, 4181 ±0.02 °C at 200 °C ±0.04 °C at 420 °C
±0.03 °C at 350 °C ±0.05 °C at 660 °C
Uniformity ±0.01 °C Full Range ±0.01 °C at 33 °C ±0.02 °C at 50 °C ±0.1 °C at 0 °C ±0.1 °C at 35 °C
Fluke 9142-X Field Metrology Well, ±0.015 °C at 200 °C ±0.05 °C at 420 °C
Low Temp ±0.02 °C at 350 °C ±0.15 °C at 660 °C
Target Size N/A N/A N/A 152.4 mm 152.4 mm
Fluke 9143-X Field Metrology Well, diameter diameter
Mid Temp Emissivity N/A N/A N/A Preset to 0.95 Preset to 0.95
Range
Fluke 9144-X Field Metrology Well, NIST YES YES YES YES YES
High Temp Accredited
Calibration

Add -P to order optional Process option 9142/9143/9144: 4180/4181


(914X-X-P). X represents insert type, Size (HxWxD): 290 x 185 x 295 mm Size (HxWxD): 241 x 356 x 241 mm
A, B, C, D, E or F Weight: 9142: 8.2 kg, 9143: 7.3 kg, 9144: 7.7 kg Weight: 4180: 9.1 kg, 4181: 9.5 kg
One Year Warranty One Year Warranty

For the complete line of Fluke heat sources


check the Fluke web at www.fluke.eu 97
717/718/718Ex/719
Pressure Calibrators

Pump up the pressure


717 Pressure Calibrators 718 Pressure Calibrators
• Measure pressure, 0.05% of full scale Same features as Fluke 717 plus:
with internal sensor • Newly designed built-in pressure/
- 1/8 NPT pressure fitting vacuum hand pump with vernier and
- Compatible with non-corrosive gasses bleed valve helps protect the pump from
and liquids damage and is easier to clean
• Pressure measurement to 700 bar
using any of the Fluke-700Pxx Pressure For 718Ex Intrinsically Safe Pressure
Modules Calibrator see chapter on Ex products in
• Wide range of selectable measurement this catalog.
units for pressure
• Current measurement with 0.015% 719 Electric Pressure Calibrator
accuracy and 0.001mA resolution Same features as Fluke 717 plus:
• Simultaneous pressure and current • Electric pump for one handed operation
Fluke 719 Fluke 717 measurement for easy P/I testing • mA source for calibrating I/P devices
• 24 volt loop power supply and 4-20 mA I/O
• Zero, Min-Max, Hold and Damping • Best in class pressure measurement
functions accuracy of 0.025%
• Pressure switch test captures set, reset
and deadband values

Specifications
Model Range Resolution Over Pressure
719 30G -850 mbar to 2.4 bar 0.1 mbar Over pressure 2xFS
719 100G -850 mbar to 8 bar 1 mbar Over Pressure 2xFS
718 1G -68.9 mbar to 68.9 mbar 0.001 mbar Over Pressure 5xFS
718 30G -850 mbar to 2 bar 0.1 mbar Over Pressure 2xFS
718 100G -850 mbar to 7 bar 0.1 mbar Over Pressure 2xFS
718 300G -850 mbar to 20 bar 1 mbar Over Pressure 375 PSI, 25 bar
717 1G -68.9 mbar to 68.9 mbar 0.001 mbar Over Pressure 5xFS
717 30G -850 mbar to 2 bar 0.1 mbar Over Pressure 2xFS
717 100G -850 mbar to 7 bar 0.1 mbar Over Pressure 2xFS
717 300G -850 mbar to 20 bar 1 mbar Over Pressure 375 PSI, 25 bar
717 500G 0 mbar to 34.5 bar 1 mbar Over Pressure 2xFS
Fluke 718Ex Fluke 718 717 1000G 0 mbar to 69 bar 1 mbar Over Pressure 2xFS
717 1500G 0 bar to 103.4 bar 0.01 bar Over Pressure 2xFS
717 3000G 0 bar to 207 bar 0.01 bar Over Pressure 2xFS
717 5000G 0 bar to 345 bar 0.01 bar Over Pressure 2xFS

For Fluke 717/718/719 models: Supported Pressure Units; psi, in. H 2O(4°C), in. H2O(20°C), cm
H2O(4°C), cm H2O(20°C), bar mBar, kPa, inHg, mmHg, kg/cm2
Included Accessories Functions: Zero, Min, Max, Hold, Damp functions
Fluke 717, 718, 718Ex and 719: Max. Voltage: 30 V
Yellow Holster (718Ex red holster), TL75 Test Operating temperature: -10°C to 55°C
leads, AC72 Alligator Clips, Single 9V alkaline Safety: CSA C22.2 No. 1010.1:1992
battery (two 9V batteries in 718 and 719), User EMC: EN50082-1:1992 and EN55022:1994 Class B
manual on CD ROM. Fluke 717: For use with non corrosive gasses and liquids
Fluke 718/719: For use with non corrosive gasses
719 also includes: Push fit connectors,
Translucent test hose.
717 719
Ordering Information Size (HxWxD): 201 mm x 98 mm x 52 mm Size (HxWxD): 210 mm x 87 mm x 60 mm
Fluke 719 30G Electric Pressure Calibrator Weight: 0.6 kg Weight: 0.912 kg
Three Year Warranty Three Year Warranty (Pump one year)
Fluke 719 100G Electric Pressure Calibrator
Fluke 718 1G Pressure Calibrator 718/718Ex
Fluke 718 30G Pressure Calibrator Size (HxWxD): 216 mm x 94 mm x 66 mm
Fluke 718 100G Pressure Calibrator Weight: 0.992 kg
Fluke 718 300G Pressure Calibrator Warranty: Three years
Fluke 718Ex 30G Intrinsically Safe Pressure
Calibrator
Fluke 718Ex 100G Intrinsically Safe Pressure Recommended Accessories
Calibrator
(Not for hazardous zones)
Fluke 717 1G Pressure Calibrator
Fluke 717 30G Pressure Calibrator
Fluke 717 100G Pressure Calibrator
Fluke 717 300G Pressure Calibrator
Fluke 717 500G Pressure Calibrator
Fluke 717 1000G Pressure Calibrator
C43 (718) C125 (717) TL220 700P27 700 LTP-1
Fluke 717 1500G Pressure Calibrator See page 118 See page 118 See page 110 See page 102 See page 102
98 Fluke 717 3000G Pressure Calibrator
Fluke 717 5000G Pressure Calibrator
705/707/707Ex/715
Loop Calibrators

4-20 mA, source, measure, simulate


705 Loop Calibrator 715 Volt/mA Calibrator
• Simultaneous mA and % • Measure loop current (0-20 mA,
• mA accuracy of 0.02% 4-20 mA) signals with 0.015% accuracy
• Measure, source and simulate mA and 0.001 mA resolution
• Push button 25% steps for fast, easy • Measure voltage output process signals
linearity checks from PLCs, transmitters
• “Span Check” for fast confirmation of • Source or simulate 24 mA loop current
zero and span • Source voltage to 100 mV or 10 V
• Selectable slow ramp, fast ramp, and • 24 V loop supply with simultaneous
step function current measurement
• 24 volt internal loop supply
• 0 - 20 mA or 4 - 20 mA default start up 707Ex Intrinsically Safe Loop
modes Calibrator
• Same features as Fluke 707
707 Loop Calibrator • For use in explosion endangered areas
Fluke 705
• Features of the Fluke 705 • ATEX certified ( II 2 G Eex ia IIC T4)
• “Quick Click” detented rotary knob for
one handed operation
• Higher accuracy: 0.015%
Fluke 715
• Mains Voltage Input protection
• 250 Ohm loop resistance for with Hart
instrumentation

Specifications
Functions 705/707/707 Ex 715
Voltage measurement
Range 0-28 V DC 0-200 mV, 0-20 V
Resolution 1 mV 10 μV 1 mV
Accuracy 705: 0.025% Rdg + 2 LSD 0.01% Rdg + 2 LSD
707/707Ex: 0.015% Rdg + 2 LSD

Current measurement
Range 0-24 mA 0-24 mA
Resolution 0.001 mA 0.001 mA
Accuracy 705: 0.025% Rdg + 2 LSD 0.015%
707/707Ex: 0.015% Rdg + 2 LSD
Fluke 707
Current sourcing
Range 0-20 mA or 4-20 mA1 0-20 mA or 4-20 mA1
Accuracy 705: 0.025% Rdg + 2 LSD 0.015% + 2 LSD
707/707Ex: 0.015% Rdg + 2 LSD
Drive capability 705: 1000 Ω @ 24 mA 1000 Ω @ 24 mA
Fluke 707Ex 707: 1200 Ω @ 24 mA
707Ex: 700 Ω 20 mA
Loop power while measuring mA 24 V 24 V
Voltage sourcing N/A 0-100 mV or 0-10 V
Display current and % of span Yes mA or %
Auto step, auto ramp Yes Yes
Span Check Yes Yes

1
will over-range to 24 mA

Included Accessories
Fluke 705/707: C10 Yellow Holster, TL75 Test
Leads, AC72 Alligator Clips, Single 9V alkaline
Fluke 705, 707, 707Ex 715
Maximum voltage: 30 V (28 V - 707Ex) Size (HxWxD): 201 mm x 98 mm x 52 mm
battery, Instruction Sheet Operating temperature: -10 to 55°C Weight: 0.6 kg
Safety: CSA C22.2 No. 1010.1: 1992 Battery: One 9V alkaline
Fluke 707Ex: Red Ex-holster, Fluke TL75 Test EMC: EN50082-1:1992 and EN55022: 1994 Class B Battery life: 4 to 20 hours
Leads, AC72 Alligator Clips, Single 9V alkaline Size (HxWxD): 164 mm x 75 mm x 47 mm; Three Year Warranty
battery, Instruction Sheet Weight: 0.35 kg
Battery: One 9 V alkaline
Fluke 715: Yellow Holster (H80M excl. TPAK), Battery life: 18 hours typical, at 12 mA
TL75 Test Leads and AC72 Alligator Clips, Three Year Warranty
Single 9V alkaline battery, Instruction Sheet

Ordering Information
Fluke 705 Loop Calibrator
Fluke 707 Loop Calibrator
Fluke 707Ex Intrinsically Safe Loop Calibrator
Fluke 715 Volt/mA Calibrator

C12A (705/707) C25 (715) TL220 TP920 T PAK (715)


See page 118 See page 118 See page 110 See page 109 See page 120
99
771, 772 and 773
mA Process Clamp Meters

mA measurements without breaking the loop.


Save time. Save money.

Fluke 771, 772 and 773 Fluke 773


• Measure 4 to 20 mA signals without • DC voltage measurement to verify 24 V
”breaking the Loop,” save time and power supplies or voltage I/O signals
money troubleshooting 4 to 20 mA • Source dc voltage to test voltage input
signals devices
• Scaled mA output signal enables a
Fluke 772 and 773 logging DMM (289) to record 4 to 20 mA
• Source 4 to 20 mA signals for testing signal without breaking the loop
control system I/O or I/Ps • mA in/out: simultaneously source a mA
• Simulate 4 to 20 mA signals for testing signal while measuring a mA signal
control system I/O with the clamp
• Measure 4 to 20 mA signals with in-
circuit measurement
• Power a transmitter with the 24 V loop
Fluke 771 power supply
• Automatically ramp and step change
the 4 to 20 mA output for remote
testing

Features
771 772 773
mA measure w/jaw O O O
mA measure In circuit O O
mA source O O
Fluke 772
mA sim O O
Loop power 24 V O O
DCV source 0-10 V O

New DCV measure 0-30 V


Scaled mA output to mA input
O
O
mA in/out O

Fluke 773 Specifications


Function Resolution and range Accuracy Notes
mA measurement 0 to 20.99 mA 0.2 % + 5 counts Measured by clamp
771, 772, 773
21.0 mA to 100.0 mA 1 % + 5 counts
Measured in series
772 and 773 mA measurement 0 to 24.00 mA 0.2 % + 2 counts
with test jacks
Maximum mA drive:
Included Accessories 772 and 773 mA source 0 to 24.00 mA 0.2 % + 2 counts
24 mA into 1,000 ohms
Fluke 771: soft carrying case and user’s manual Maximum voltage
772 and 773 mA simulate 0 to 24.00 mA 0.2 % + 2 counts
Fluke 771 + 772: plus TL75 test leads, AC72 50 V dc
2 mA maximum
alligator clip set and TL940 mini-hook test 773 Voltage source 0 to 10.00 V dc 0.2 % + 2 counts
drive current
lead set 773 Voltage measure 0 to 30.00 V dc 0.2 % + 2 counts

Ordering Information Size (HxWxD): Battery Life: 771: 20 hours typical


Fluke 771 Milliamp Process Clamp Meter 771: 212 mm x 59 mm x 38 mm 772 + 773: 12 hours @ 12 mA source into
Fluke 772 Milliamp Process Clamp Meter 772 + 773: 248 mm x 76 mm x 41 mm 500 ohms
Fluke 773 Milliamp Process Clamp Meter Weight: 771: 0.26 kg IP Rating: IP 40
772 + 773: 0.42 kg Warranty: 3 years, 1 year on mA clamp
Battery: 771: 2x 1.5V Alkaline, IEC LR6 accessory and cable
772 + 773: 4x 1.5V Alkaline, IEC LR6

100
787/789 ProcessMeters

Double your power


The Fluke 787 and 789 ProcessMeters FlukeView Software for graphical analysis
combine a Digital Multimeter and a Loop and reporting.
Calibrator in one rugged handheld tool,
giving process technicians double the
power.
The Fluke 789 has a built-in 24 V loop
supply which reduces the need for
taking a separate power supply when
doing offline transmitter testing. The
IR communication port of the Fluke
789 allows data to be logged to optional

Features
787 789
DMM and Loop Calibrator in one tool O O
Precision 1000 V, 440 mA True RMS Digital Multimeter O O
Fluke 787
DC current source and Loop Calibrator O O
24 V Loop power supply O
Min/Max / Average / Hold / Relative Modes O O
Diode Test and Continuity Beeper O O
Manual Step (100%, 25%, Coarse, Fine) plus Auto Step and Auto Ramp O O
Simultaneous mA and % of scale read-out O O
Externally accessible battery / fuses O/- O/O
HART mode setting with loop power and a built-in 250 Ω resistor O
Fluke 789 0% and 100% buttons to toggle between 4 and 20 mA sourcing for a quick span check O
Infrared I/O serial port O

Specifications
787 789
Voltage measurements
Range 0-1000 V AC or DC 0-1000 V AC or DC
Resolution 0.1 mV to 1.0 V 0.1 mV to 1.0 V
Accuracy 0.1% Rdg+1 LSD (V DC) 0.1% Rdg+1 LSD (V DC)
Current measurement
Range 0-1 A 0-30 mA 0-1 A 0-30 mA
Resolution 1 mA 0.001 mA 1 mA 0.001 mA
Accuracy 0.2%+2 LSD 0.05%+2 LSD 0.2%+2 LSD 0.05%+2 LSD
Current Sourcing
Range 0-20 mA or 4-24 mA 0-20 mA or 4-24 mA
Accuracy 0.05% of span 0.05% of span
Other specifications
Max drive capability 500 Ω 1200 Ω
True RMS Loop power N/A 24 V
Resistance measurement To 40 MΩ, 0.2%+1 LSD To 40 MΩ, 0.2%+1 LSD
Frequency To 19.999 kHz, 0.005%+1 LSD To 19.999 kHz, 0.005%+ LSD
Continuity Beeps for resistance < 100 Ω Beeps for resistance < 100 Ω
Span Check No Yes
Included Accessories
787: Yellow Holster (H80M excl. TPAK), TL75
Hard Point Test Lead Set plus AC72 Alligator Maximum voltage: 1000 V 789
Clips, one 9V battery, user manual Operating temperature: -20 to 55ºC Size (HxWxD): 203 mm x 100 mm x 50 mm
789: TL71 Test Lead Set plus AC72 Alligator Weight: 0.6 kg
Clips, four 9V AA alkaline batteries, user 787 Battery: Four AA alkaline batteries
manual and quick reference guide. Size (HxWxD): 201 mm x 98 mm x 52 mm Battery life: 14 to 140 hours typical
Weight: 0.642 kg Three Year Warranty
Battery: One 9 V alkaline
Ordering Information Battery life: 12 to 50 hours typical
Fluke 787 ProcessMeter Three Year Warranty
Fluke 789 ProcessMeter
FVF-SC2 FlukeView Forms Software
including interface cable Recommended Accessories

C125 TL220 80T-150U i400 i410


See page 118 See page 110 See page 116 See page 114 See page 115
101
Field Calibrator Accessories

Fluke 700 Series Pressure Modules


• Ranges from 2.5 mbar to 700 bar. • Compatible with Fluke 717, 718, 725 and
• Gage, differential, dual (compound), 74x series.
absolute and vacuum modules • Rugged cases protect the modules from
• Very high accuracy: up to 0.025% FS harsh environments
• Full-accuracy performance for 0°C to 50°C • All modules include NIST traceable
• Pressure readings update twice per certificate and test data
second, and may be displayed in up to 11 • ATEX certified Ex versions available
different units ( II 1 Eex ia IIB T4)

Model Range (approx.) Resolution Reference High side media Low side media Fitting material Max
uncertainty overpressure2)
(23 ± 3°C) (FS)
Differential
700P00 2.5 mbar 0.001 mbar 0.3 % Dry 1) Dry 316 SS 30x
700P01/700P01Ex 25 mbar 0.01 mbar 0.2 % Dry Dry 316 SS 3x
700P02 70 mbar 0.007 mbar 0.15 % Dry Dry 316 SS 3x
700P22 70 mbar 0.007 mbar 0.1 % 316 SS Dry 316 SS 3x
700P03 340 mbar 0.01 mbar 0.05 % Dry Dry 316 SS 3x
700P23 340 mbar 0.01 mbar 0.025 % 316 SS Dry 316 SS 3x
700P04 1000 mbar 0.1 mbar 0.025 % Dry Dry 316 SS 3x
700P24/700P24Ex 1001 mbar 0.1 mbar 0.025 % 316 SS Dry 316 SS 3x
Gage
700P05/700P05Ex 2 bar 0.1 mbar 0.025 % 316 SS N/A 316 SS 3x
700P06/700P06Ex 7 bar 0.7 mbar 0.025 % 316 SS N/A 316 SS 3x
700P27/700P27Ex 20 bar 1 mbar 0.025 % 316 SS N/A 316 SS 3x
700P07 34 bar 1 mbar 0.025 % 316 SS N/A 316 SS 3x
700P08 70 bar 7 mbar 0.025 % 316 SS N/A 316 SS 3x
700P09/700P09Ex 100 bar 10 mbar 0.025 % 316 SS N/A 316 SS 2x
Absolute
700PA3 340 mbar 0.01 mbar 0.05 % 316 SS N/A 316 SS 3x
700PA4/700PA4Ex 1000 mbar 0.1 mbar 0.05 % 316 SS N/A 316 SS 3x
700PA5 2 bar 0.1 mbar 0.05 % 316 SS N/A 316 SS 3x
700PA6 7 bar 0.7 mbar 0.05 % 316 SS N/A 316 SS 3x
Vacuum
700PV3 -340 mbar 0.01 mbar 0.04 % 316 SS Dry 316 SS 3x
700PV4 -1000 mbar 0.1 mbar 0.04 % 316 SS Dry 316 SS 3x
Dual
700PD2 ± 70 mbar 0.007 mbar 0.15 % 316 SS Dry 316 SS 3x
700PD3 ± 340 mbar 0.01 mbar 0.04 % 316 SS Dry 316 SS 3x
700PD4 ±1000 mbar 0.1 mbar 0.025 % 316 SS Dry 316 SS 3x
700PD5 -1000/+2000 mbar 0.1 mbar 0.025 % 316 SS N/A 316 SS 3x
700PD6 -1000 mbar/+6.9 bar 1 mbar 0.025 % 316 SS N/A 316 SS 3x
700PD7 -1000 mbar/+13.8 bar 1 mbar 0.04 % 316 SS N/A 316 SS 3x
High
700P29/700P29Ex 200 bar 0.01 bar 0.05 % C276 N/A C276 2x
700P30 340 bar 0.01 bar 0.05 % C276 N/A C276 2x
700P31 700 bar 0.07 bar 0.05 % C276 N/A C276 1.5x
1)“Dry” indicates dry air or non-corrosive gas as compatible media. “316 S S” indicates media compatible with Type 316 Stainless Steel. “C276” indicates media compatible with Hastelloy C276.
2)Maximum overpressure specification includes common mode pressure.

Other accessories

700LTP-1 Low-pressure Test Pump 700HTH-1 Hydraulic Test Hose


• For low pressure applications • Hydraulic test hose is a 10,000 psi, 690 bar
• Vacuum to -13 psi / -.90 bar
• Pressure to 100 psi / 6.9 bar 700ILF In-Line Filter for the
• With fine-control, adjustable relief valve Fluke 718
and slow bleed capability
700PCK Pressure Module
700PTP-1 Pneumatic Test Pump-1
Calibration Kit
• Handheld pressure pump
• Pressures up to 600 psi, 40 bar
BP7235 NiMH Battery Pack
700HTP-1 Hydraulic Test Pump
• Pressures up to 10,000 psi/690 bar. BE9005 Battery Eliminator

700PRV-1 Pressure Relief Valve


Fluke 700LTP-1 Fluke 700PTP-1
• Pressure relief valve for 700HTP-1
• Adjustable from 725 to 5800 PSI (50 to 200
102 bar)
Vibration Tester

With the Fluke 810 Vibration Tester you will be able to control unplanned
downtime, prevent recurring problems, set repair priorities and manage
your resources with an entirely new approach to vibration testing. In three
quick, easy steps, the new Fluke 810 helps you locate and diagnose com-
mon mechanical problems and prioritize their repair actions. The combi-
nation of powerful algorithms and a database of real-world measurement
experience make the Fluke 810 the most advanced troubleshooting tool
for mechanical maintenance teams who need an answer now.

103
810 Vibration Tester

New
Motor diagnosis and repair in three simple steps
The Fluke 810 Vibration Tester is the Features and benefits
most advanced troubleshooting tool • On-board identification and location of
for mechanical maintenance teams the most common mechanical faults
who need an answer now. The unique (bearings, misalignment, unbalance,
diagnostic technology helps you quickly looseness) focus maintenance efforts
identify and prioritize mechanical on root cause, reducing unplanned
problems, putting the expertise of a downtime
vibration analyst in your hands. • Fault severity scale with four severity
levels help you prioritize maintenance
Use the vibration tester to: work
• Troubleshoot problem equipment and • Repair recommendations advise
understand the root cause of failure technicians on corrective action
• Survey equipment before and after • On-board context sensitive help provide
planned maintenance and confirm the real-time tips and guidance to new
Fluke 810
repair users
• Commission new equipment and • 2 GB expandable on-board memory
ensure proper installation provide enough space for your
• Provide quantifiable proof of equipment machinery’s data
condition and drive investment in • Self-test functions ensure optimal
repair or replacement performance and more time on the job
• Prioritize and plan repair activities and • Laser tachometer for accurate machine
operate more efficiently running speed promotes confident
Set-up • Anticipate equipment failures before diagnoses
they happen and take control of spare • Tri-axial accelerometer reduces
parts inventories measurement time by 2/3 over single
• Train new or less-experienced axis accelerometers
technicians and build confidence and • Viewer PC Software expands data
skill across the team storage and tracking capacity
• Color LCD display and intuitive
multilingual, icon-based user interface
Measure promote use right out of the box

Specifications
(Check the Fluke web for detailed specifications)
Diagnose
Diagnostic specifications
Standard faults Unbalance, looseness, misalignment and bearing failures
Analysis for Motors, fans, blowers, belts and chain drives, gearboxes, couplings, centrifugal pumps,
piston pumps, sliding vane pumps, propeller pumps, screw pumps, rotary thread/gear/
Language support: lobe pumps, piston compressors, centrifugal compressors, screw compressors, closed
eng, ger, fre, ita, spa, por coupled machines, spindles
Machine rotational 200 rpm to 12000 rpm
speed range
Diagnosis details Plain-text diagnosis, fault severity (slight, moderate, serious, extreme), repair details,
cited peaks, spectra
Electrical specifications
Ranging Automatic
A/D converter 4 channel, 24 bit
Usable bandwith 2 Hz to 20 kHz
Sampling 51.2 kHz
Included Accessories
Digital signal Automatically configured anti-alias filter, high-pass filter, decimation, overlapping,
Tri-axial TEDS accelerometer, accelerometer processing functions windowing, FFT, and averaging
magnet mount, accelerometer mounting Sampling rate 2.5 kHz to 50 kHz
pad kit with adhesive, accelerometer quick Dynamic range 128 dB
disconnect cable, laser tachometer and Amplitude accuracy ±0.1 dBV
storage pouch, smart battery pack with cable FFT resolution 800 lines
and adapters, shoulder strap, adjustable Spectral windows Hanning
hand strap, Viewer PC application software, Frequency units Hz, orders, cpm
mini-USB to USB cable, getting started guide, Amplitude units in/sec, mm/sec, VdB (US), VdB (Europe)
Non-volatile nemory SD micro memory card, 2 GB internal + user accessible slot for additional storage
illustrated quick reference guide, users
manual CD-ROM, instructional training CD-
ROM, hard carrying case.

Battery type: Lithium-ion, 14.8 V 2.55 Ah Warranty: Three years on tester


Ordering Information Size (HxWxD): 186 x 267 x 70 One year on sensor and tachometer
Fluke 810 Vibration Tester Weight: 1.9 kg
104
ATEX Certified Test Tools

The Fluke line of intrinsically safe tools is designed to meet the needs of
technicians working in and around hazardous areas. The tools are ideal
for environments in chemical plants, petro-chemical plants, oil plat-
forms, refineries and other locations where risk of explosion exists. The
products are easily recognizable from standard Fluke products by their
lighter grey colour and red holster.

105
A brief look at ATEX

Intrinsic safety is a protection standard What is “Intrinsically Safe”? this date onwards, all products sold for
employed in potentially explosive Intrinsically safe standards apply to all use in explosive atmospheres must have
atmospheres. Devices that are certified equipment that can create one or more ATEX certification and carry the distinctive
of a range of defined potential explosion symbol:
as “intrinsically safe” are designed to be
sources:
unable to release sufficient energy, by
The Fluke Ex (IS) product line
either thermal or electrical means, to cause • Electrical sparks Fluke is among the first manufacturers to
ignition of flammable material (gas, dust/ • Electrical arcs produce handheld test tools according to
particulates). • Flames the latest ATEX standards. The Fluke line of
• Hot surfaces intrinsically safe tools is designed to meet
• Static electricity the needs of technicians working in and
• Electromagnetic radiation around hazardous areas:
• Chemical reactions • Install, maintain and troubleshoot
• Mechanical impact equipment by using the new Fluke 87V Ex
• Mechanical friction Digital Multimeter
• Compression ignition • Maintain and calibrate sensors,
• Acoustic energy transmitters and control loops with the
• Ionizing radiation line of Ex field calibrators
The tools are ideal for environments
What industries are intrinsically in petro-chemical plants, oil platforms,
safe products designed for? refineries and other locations subject to risk
• Petro-chemical of explosion.
• Oil platforms and refineries Apart from having the ATEX markings, the
• Pharmaceutical visual difference between a standard Fluke
• Bulk materials (e.g. grain) tool and the corresponding Ex version is
• Mining the different grey body colour and a red,
• Pipelines conductive holster designed specifically
• Any environment where explosive gases to eliminate the potential for electrical
are present discharge.
Inside, the Fluke Ex tools have been
What is ATEX? reengineered to reduce energy avoiding
The primary intrinsically safe standard has generation of heat and electrical sparks.
been set in the European Union with the They are premium products designed for
9/94/EC Directive, commonly called ATEX ultimate safety.
(“Atmosphères Explosibles,” French for
explosive atmospheres). The stated goal of Making sense of ATEX certification
the guidelines is to “help ensure the free Fluke 707Ex is ATEX-compliant and is
movement of products in the European certified II 2 G EEx ia IIC T4— but what
Union” by “minimizing the number of exactly does that mean?
safeguard clause applications, at least those
originating from divergent interpretations
The ATEX rules have been in place as a
voluntary standard since 1 March 1996.
The rules are mandatory on electrical
and electronic equipment for use in
environments subject to explosion hazard Here a brief explanation of the ATEX
sold in the EU starting 1 July 2003. From certification designations.

ATEX certification 707Ex


The ATEX examination mark. This sign is required on all devices used in European hazardous
areas.
The classification of zones.
“II” designates the tool is approved for all non-mining areas.
II 2 G “2” represents the category of the device, in this case the device is rated for the second most
hazardous areas.
“G” designates atmosphere, in this case gas, vapors and mist.
EEx Explosion protection based on European Ex-regulations.
The type of protection from explosion, in this case the energy in a device or connector has
ia
been reduced to a safe value.
IIC Gas Group. “IIC” indicates compatibility with the most dangerous gas group.
Temperature class gives the user the maximum temperature of a surface that may be in
T4
contact to the Ex atmosphere under fault conditions. T4 is rated at 135°C.

106
ATEX-certified Test Tools

Fluke intrinsically safe tools for tough measurement and


calibration tasks

Fluke 87V Ex Intrinsically safe Fluke 707Ex Fast, one-handed tool for
version of the world’s most popular loop checks
multimeter The Fluke 707Ex is the ideal, stand alone
With its high performance, accuracy and tool for calibration and maintenance of 4
motor drive compatibility, the Fluke 87V to 20 mA control loops. It provides 24V loop
is the most popular industrial multimeter power while measuring mA, and lets you
around. Now Fluke has introduced a new measure and source/simulate mA with 1 μA
intrinsically safe version – the 87V Ex – for resolution.
measurements in and around hazardous • ATEX safety rating
areas. II 2G EEx ia IIC T4
The Fluke 87V Ex has all the measurement
and troubleshooting functions of the proven See also page 99
Fluke 87V. Unlike other ATEX-certified tools,
it can be used both inside and outside the
hazardous zone (ATEX Zones 1 & 2) without
compromising performance or compliance.
So there’s no need to carry different tools
Fluke 87V Ex for use in specific zones. It also has a built- Fluke 707Ex
in thermometer with TC probe, further
reducing technicians’ tool counts.
• ATEX safety rating II 2G EEx ia IIC T4 Fluke 718Ex Self-contained Pressure
• EN61010-1 CAT III 1000V/CAT IV 600V
electrical safety rating
Calibrator
The Fluke 718Ex offers a convenient,
self contained solution for pressure
See also page 17
measurements and calibration. With its
internal pressure sensor and pump, it’s
ready for immediate, stand alone use. The
pressure range can easily be extended to up
to 200 bar with any of the 8 Fluke 700PEx
Pressure Modules.
• ATEX safety rating
II IG EEx ia IIC T4

See also page 98


Fluke 725Ex Intrinsically safe
Multifunction Process Calibrator
The Fluke 725Ex intrinsically safe
Multifunction Process Calibrator is powerful
yet easy-to-use. Combined with the Fluke 718Ex
Fluke 700PEx Pressure Modules, the 725Ex
is able to calibrate almost any process
instrument likely to need service in any
area where explosive gases may be present.
Fluke 700Ex Pressure Modules
• ATEX safety rating
These intrinsically safe pressure
II IG EEx ia IIB 171°C
modules for use with the Fluke 725Ex
Multifunctional Process Calibrator and
See also page 94
Fluke 718Ex Pressure Calibrator cover the
most commonly used pressure calibration
ranges from 0-25 mbar and 0-200 bar.
There’s a choice of 8 gage, differential and
absolute modules.
Fluke 725Ex • ATEX safety rating
Fluke 700Ex
II 1G EEx ia IIC T4

See also page 102

107
General Accessories

The best test tools deserve accessories designed and manufactured


to the same high quality and safety standards. So we also provide a
comprehensive range of test leads, probes and clips, current clamps,
temperature accessories and dedicated electronic and automotive
accessories. And to protect your valuable instrument, choose a rugged
Fluke tailor-made holster or case.

108
Electronic Test Leads,
Probes & Clips

Test Leads Test Leads / Patch Cords

TL910 Electronic Test Lead Set TL960 Micro-Hook Test Lead Set TP920 Test Probe Adapter Kit
• Very small 1 mm tips to access hard • 1 pair (red, black) of test leads with • Set of push-on adapters for TL71 and TL75
to reach test points multi-stacking 4 mm banana test probes
• Probe tip length up to plugs and micro-hooks • IC test adapters,
100 mm, test lead length: • Micro-hooks attach to extended probe tips,
1m component leads up to 1 mm medium alligator clips
• Included: 3 sets of diameter (max.opening
spring loaded gold tips • 90 cm long PVC insulated leads 7.6 mm)
and 2 sets of stainless steel tips • 30 V rms or 60 V DC, 15 A • CAT II 300 V, 5 A rating
• CAT IV 600 V, CAT III 1000 V,
3 A rating
TL930 Patch Cord Set (60 cm) TL970 Hook and Pincer Kit
• 1 pair (red, black) • TL940 Mini-Hook Test Lead Set
multi-stacking 4 mm banana plug • TL950 Mini-Pincer Test Lead
TP912 Replacement Tips for TL910 patch cords Set
• Replacement tips for TL910 • Nickel-plated banana • TL960 Micro-Hook Test Lead
• Five sets of gold plated and stainless plugs Set
steel tips • 61 cm long
PVC insulated leads
• 30 V rms or 60 V DC, 15 A
TL81A Deluxe Electronic Test Lead Kit
• Includes components of TL80, plus one pair
(red, black) each
modular 1 meter
TL40 Retractable Tip Test Lead Set TL932 Patch Cord Set (90 cm) long silicone test
• One pair (red, black) of test leads with • 1 pair (red, black) multi-stacking 4 mm lead, test probe,
sharp needle point tips adjustable banana plug patch cords hook-style and
to desired length from 0 to • Nickel-plated banana pinch style clip,
76 mm plugs alligator clip, IC
• Extra hard probe tips • 90 cm long probe tip adapter
to provide long service life PVC insulated leads and spade lugs
• Flexible silicone insulated test • 30 V rms or 60 V DC, 15 A • Quadfold soft
leads carrying case
• CAT II 150 V, 3 A rating, UL listed • CAT II 300 V. UL listed
TL935 Patch Cord Kit
(60, 90, 120 cm)
• 3 sets (red and black pairs) of TLK287 Electronic Master Test Lead Kit
TL940 Mini-Hook Test Lead Set multi-stacking 4 mm banana • Includes modular leads, probes (black and
• 1 pair (red, black) of test leads with multi- plug patch cords red), minigrabber/jack
stacking 4 mm banana plugs and • Nickel-plated banana plugs set, medium alligator
mini-hooks • 60 cm, 90 cm, 120 cm long PVC clips (black and red),
• Mini-hooks attach to insulated leads spade lug/banana jack
component leads up to • 30 V rms or 60 V DC, 15 A plated (set), couplers
1.5 mm diameter IEC1010 (black and red),
• 90 cm long PVC micrograbbers and
insulated leads -leads (black and red)
• 30 V rms or 60 V DC, 15 A • TL910 Electronic Test
Lead Set
• Quadfold Pouch
• CAT III 1000 V (probes only)

BP980 Double Banana


TL950 Mini-Pincer Test Lead Set Kits Plug Kit
• 1 pair (red, black) of test leads with • 5 pair (red, black) of
multi-stacking 4 mm banana plugs TL80A Basic Electronic Test Lead Kit double
and mini-pincers • One pair (red, black) each 1 meter long 4 mm banana plugs
• Mini-pincers open to silicone test lead set, • Each plug has
2.3 mm alligator clip and probe tip 3.1 mm holes for
• 90 cm long PVC insulated extender. mounting wires and
leads • C75 soft carrying case components
• 30 V rms or 60 V DC, 15 A • CAT II 300 V. UL listed • Brass plugs/jack, beryllium copper springs
• 30 V rms or 60 V DC, 15 A

109
Industrial Test Leads,
Probes & Clips

Test Leads Modular Test Leads Kits

TL71 Premium Test Lead Set TL221 SureGrip™ TL220 SureGrip™


• One pair (red, black) comfort grip probes Extension Lead Set Industrial Test Lead Kit
with silicone insulated, right-angle • One pair (red, black) of silicone • AC220 SureGrip™ Alligator
test leads insulated leads with straight Clip Set
• Recommended for μV connectors on both ends • TP220 SureGrip™ Test
measurements • Reinforced strain relief Probe Set
• CAT IV 600 V, CAT III • Includes one pair (red, black) • TL222 SureGrip™
1000 V, 10 A rating. of female couplers Silicone Test Lead Set
UL listed • Extends test leads by 1.5 m (right to right)
• 600 V CAT IV, 1000 V CAT III,
10 A rating. UL listed

TL75 Hard Point™ Test Lead Set TL222 SureGrip™ TL223 SureGrip™
• One pair (red, black) comfort grip probes Silicone Test Lead Set Electrical Test Lead Kit
with PVC insulated, test leads with • DMM test leads (red, black) • AC220 SureGrip™ Alligator Clip
right-angle shrouded banana with safety shrouded, standard Set
plugs diameter banana plugs • TP1 Slim-Reach™ Test
• Recommended for • Right angle connector on Probes (flat bladed)
general purpose both ends • TL224 SureGrip™ Silicone
measurements • Reinforced strain relief Test Lead Set
• CAT IV 600 V, CAT III 1000 V, • 1.5 meter silicone-insulated (straight to right)
10 A rating. UL listed wire resists heat & cold
• CAT IV 600 V, CAT III 1000 V,
10 A rating. UL listed TL238 SureGrip™ High Energy
Test Lead Kit
• TP238 SureGrip™ Insulated Tip Test
TL76 All-in-one Test Lead Set TL224 SureGrip™ Probes with less than 4 mm of
• One pair (red, black) 1.5 meter long Silicone Test Lead Set exposed metal (GS38) with
silicone test leads with right • DMM test leads (red, black) flexible removable finger
angle shrouded banana plug with safety shrouded, banner
• Lantern tip (removable) standard diameter banana • TP280 20 cm Test Probe
for use with European plugs Extenders
wall sockets (4 mm Ø ) • Right angle connector on one end and • TL224 SureGrip™ Silicone
• Lantern tip can be removed straight connector on the other Test Lead Set
for easy access to terminal • Reinforced strain relief
blocks (2 mm Ø) • 1.5 meter silicone-insulated wire resists
• Removable, insulated IC caps allow probing heat & cold TLK-220 EUR SureGrip™
on closely spaced leads and compliance with • CAT IV 600 V, CAT III 1000 V, 10 A rating.
GS38. Accessory Kit
UL listed • AC220 SureGrip™ Alligator
• Cat IV 600 V, CAT III 1000 V, 10 A rating,
UL listed Clip Set
• AC285 SureGrip™ Large Jaw
TL27 Heavy Duty Alligator Clip Set
Test Lead Set • TP74 Slim Reach Test Probe Set
• DMM test leads (red, black) (4 mm)
with safety shrouded, • TL224 SureGrip™ Silicone Test Lead Set
standard diameter banana • Large zippered soft case with moveable
plugs divider
• Heavy duty EPDM insulation
• Length 1.5 m
• CAT III 1000V, 10A rating.
UL listed

H900 Test Lead


Holder
• Heavy duty
construction with
mounting holes
• Holder has 10 slots for wires up to
SureGrip™ accessories are designed to
8 mm in diameter
improve steadiness in slippery hands.
• Over-all dimensions: 27.9 cm
Rubber overmolded surfaces and finger-
L x 8.9 cm W x 3.2 cm H
hugging curves give the user a comfortable,
reliable grip on the accessory so they can
focus on making an accurate measurement.

110
Industrial Test Leads,
Probes & Clips

Modular Test Probes Modular Test Probes


Kits (for use with Modular Test Leads) (for use with Modular Test Leads)

TLK-225 SureGrip™ TP220 SureGrip™ Test Probe Set TP80 Electronic Test Probe Set
Master Accessory Kit • One pair (red, black) of Industrial test probes Recommended for use with TL222
• AC220 SureGrip™ Alligator • Sharp, 12 mm stainless steel tip and TL224
Clip Set provides reliable contact • One pair (red, black)
• AC280 SureGrip™ Hook Clip Set • Flexible finger barrier improves • IC insulated cap prevents
• AC283 SureGrip™ Pincer Clip Set grip shortening of IC legs for
• AC285 SureGrip™ Large Jaw • Recommended for use probing high density components or boards
Alligator Clip Set with TL222 and TL224 • CAT III 1000 V, 10 A rating. UL listed
• TP220 SureGrip™ Test Probe Set test leads
• TL224 SureGrip™ Silicone Test • CAT IV 600 V; CAT III 1000 V, 10 A rating.
Lead Set UL listed
• 6-Pocket Storage Pouch TLK291 Fused Test Probe Set
• One pair (red, black) fused test probes
• Designed to meet GS38 specs for
United Kingdom
TP74 Lantern Tip Test Probe Set • CAT III 1000V, 0.5A
TLK289 EUR Industrial Master
• One pair (red, black) • Fuse rating:
Test Lead Kit • Tips include banana-style spring 500 mA/1000 V/FF/50 kA
• C116, Soft Case contacts with nickel-plated brass
• AC220 Alligator Clip Set ends
• AC280 Hook Clip Set • CAT III 1000 V, 10 A rating.
• AC285 Large Jaw
Alligator Clip Set
UL listed New
• TP74 Lantern Tip
Test Probe Set FTP SureGrip™ Fused Test
• TL224 Test Lead Set TLK290 Test Probe Kit Probes
• TPAK Hanging Kit • Kit includes three flexible socket probes • Built-in fuses for added
• 80BK-A Temperature Thermocouple and a large alligator clip protection
• To be used on • 2 mm threaded probe tips include removable
three phase sockets. 4 mm lantern-style spring contacts
• Probes have flexible width • Removable GS38 insulted IC caps for probing
ACC-T5-KIT Accessory Kit for test points that fit securely in closely spaced leads
use with T5 4 to 8 mm sockets. • CAT III 1000 V, CAT IV 600 V, 10A
This kit completes the offering of a T5 • CAT III 1000 V, 8 A
with add-on probes and
carrying case.
• TP220 SureGrip™ Test Probe Set
• AC285 SureGrip™ Large Jaw Alligator TP1, TP2, TP4, TP38 New
Clip Set SlimReach Test Probe Sets
• C33 Soft Meter Case • One pair (red, black) of slender probes for
FTPL SureGrip™
closely spaced or recessed terminals
• TP1: Flat blade design to hold Fused Test Probes
securely in blade type wall with Leads
sockets • FTP Fused Test Probes with built-in fuses for
L215 SureGrip™ Kit • TP2: 2 mm diameter added protection
with Probe Light and tip for electronics work. • Includes TL224 Silicone Insulated Test Leads
Extender Also compatible with AC72. • CAT III 600 V, CAT IV 600 V, 10 A
• L200 Probe Light • TP4: 4 mm diameter tip
• TP280 20 cm Test Probe designed to fit into IEC wall
Extenders outlets
• TP220 SureGrip Test Probes • TP38: Insulated probe tip
• TL224 SureGrip Silicon Test Lead Set (designed to meet GS38 specs for
• Foldable soft pouch with six pockets and United Kingdom).
hook-and-loop • CAT IV 600 V, CAT III
1000 V, 10 A rating,
UL listed

111
All accessories have a one year warranty
Industrial Test Leads,
Probes & Clips

Modular Clips Modular Clips Push-on Clip


(for use with Modular Test Leads) (for use with Modular Test Leads) (for use with TL71 and TL75 Test Lead Sets)

AC220 SureGrip™ Alligator Clip Set AC285 SureGrip™ AC72 Alligator Clip Set
• One pair (red, black) of small, insulated, Large Jaw Alligator Clip Set • Slide-on alligator clips (red,
nickel plated jaws • One pair (red, black) of large alligator black) for TL71/TL75
• Blunt tip grabs round screw heads up clips with nickel-plated steel jaws • Jaws provide 8 mm opening
to 9.5 mm • Multi-purpose tooth pattern grips • CAT IV 600 V, CAT III 1000 V,
• Recommended for use with anything from fine gauge wire to • 10 A rating. UL listed
TL222 and TL224 test leads a 20 mm bolt
• CAT IV 600 V, CAT III • Recommended for use with
1000 V, 10 A rating. TL222 and TL224 test leads
UL listed • CAT IV 600 V; CAT III 1000 V, 10 A rating.
UL listed Test Leads and Probes in one
AC280 SureGrip™ Hook Clip Set
• One pair (red, black) of nickel plated clips
• Profile narrows to 5.6 mm at The new standard for safer electrical
tip, hook opening 6.4 mm at front, measurements
AC87 Heavy Duty Bus Bar Clip Set
2 mm at base TL175 and TP175 TwistGuard™ test leads are
• One pair (red, black) of
• Recommended for use with the latest in the SureGrip™ technology from
flat, right angle design
TL222 and TL224 test leads Fluke that provides two safety features in
for connecting to bus
• CAT IV 600 V, CAT III 1000 V, one set of test leads. These new patented test
bars
3 A rating. UL listed leads provide two category rated tips
• Adjustable collar
provides 2 ranges of jaw (CAT III/IV) with a simple twist of the shroud.
openings up to 30 mm The lead wires on the TL175 are equipped with
• CAT III 600 V, 5 A rating. UL listed wear indication, that show when the leads
AC283 SureGrip™ Pincer Clip Set have excessive wear and that it is time to
• One pair (red, black) of nickel plated replace them. The TL175 and TP175 meet the
pincers open to 5 mm new NFPA 70E (IEC 61010-031) safety standard
• 11.4 cm flexible insulated shaft which is the standard for electrical safety in
• Recommended for use with the workplace.
TL222 and TL224 test AC89 Heavy Duty Insulation
leads Piercing Test Clip
• CAT IV 600 V, CAT III • Single probe pierces
1000 V, 1 A rating. 0.25 to 1.5 mm insulated wire New
UL listed • Small pin allows self-healing of the
insulation
• CAT IV 600V, CAT III 1000 V, 5 A rating.
UL listed

TL175 TwistGuard™ Test Leads


• Probes meet new IEC 61010 requirements for
safety
• Patented extendable tip sheath meets new
CAT III 1000 V, CAT IV 600 V requirements
while providing the flexibility you need for
CAT II measurements
• Double insulated silicone leads with Wear
indication for increased safety
• Probes always show correct Category rating
for tip being used
• Advanced strain relief exceeds 5,000 bend life
• One-year warranty

SureGrip™ accessories are designed to


improve steadiness in slippery hands.
Rubber overmolded surfaces and finger-
hugging curves give the user a comfortable,
112 reliable grip on the accessory so they can
focus on making an accurate measurement. All accessories have a one year warranty
Automotive Accessories

Piercing Clips Pressure Module TL 82 Automotive


Pin & Socket Adapter
TP81 and TP82 Insulation Piercing PV350 Pressure Vacuum Module Kit
Clip Set • Compatible with all Fluke and most popular This set of male and female
• Banana jack accepts all DMM DMMs adapters allows you to make firm
and banana jack leads • Digital pressure and connection to pin and socket
• Available for 4 mm input, vacuum measurements in connectors.
modular connection with a single module Kit contains:
TP81 or available as a 2 mm input to • Transducer sealed in 316 • Retractable shrouded test lead set
slip onto probe tips with the TP82 stainless steel compatible with • Complete set of 8 pin-and-socket adapters
• Tested to 60 V DC variety of liquids and gases with flexible tips
• Measures vacuum to 76 cm Hg • One red and black in different sizes
• Display results in English (psig or Hg) or • Rated to 60 V DC
metric (kPa or cm Hg) units
• Measures pressure to 500 psig (3447 kPa)
TP84 Oxygen Sensor Insulation
Piercing Clip Current Probe
• Banana jack accepts
all DMM and banana 90i-610s AC/DC Current Probe (600 A)
jack leads (4 mm) • Current Range: 2 to 600A DC or AC Peak
• Tested to 60 V DC Test Leads • Basic Accuracy (DC to 400Hz):
± (2% of reading + 1A)
TL28A Automotive • Output Signal: 100A range:
Test Lead Set 10mV/A 600A range: 1mV/A
• Flexible silicone insulated • Frequency Range: 40Hz to
leads are heat and cold 400Hz
Probe Pins resistant • Working Voltage: 600V
• CAT I 30 V, 10 A AC rms
TP88 Rigid Back Probe Pin Set • Maximum Conductor
• Slides onto test probes measuring Diameter: 34 mm
2 mm TLK281 SureGrip™
• Tested to 60 V DC Automotive
Test Lead Kit
Kit contains: Inductive Pick-up
• TP81 Insulation
Piercing Clip Set RPM80 Inductive
TP40 Automotive Back • TL224 SuregripTM
Probe Pins (five) Silicone Test Lead Set
Pick-up
• Banana jack accepts all • Provides RPM readings
• TP220 SuregripTM Test Probe Set
DMM and banana jack • AC220 SuregripTM Alligator Clip Set
leads (4 mm) • AC285 SuregripTM Large Jaw Alligator Clip Set
• Tested to 60 V DC • Soft Case
ScopeMeter
Accessory Kits
SCC128 Automotive
Accessory Kit
Banana Plugs (120 Series)
BP880 BNC to Female Double TLK282 SureGrip™
Stacking Banana Plug Deluxe Automotive Test
BP881 BNC to Male Lead Kit
Double Stacking Kit contains:
Banana Plug • TP81 Insulation SCC198 Automotive
• Allows for hands-free BP880 Piercing Clip Set Accessory Kit
testing in controlled voltage • TP40 Automotive (190 Series)
environments Back Probe Pins
500 VRMS maximum (five)
• Banana plug is nickel- • TL224 SuregripTM Silicone Test
plated, beryllium copper for BP881 Lead Set
low contact resistance • TP220 SuregripTM Test Probe Set
• AC220 SuregripTM Alligator Clip Set These kits provide a host of accessories
• The BNC shell is plated for tarnish resistance
• AC285 SuregripTM Large Jaw Alligator that allow you to easily and quickly make
• Operating temperature +50°C maximum
Clip Set measurements on automotive electronic
• AC280 SuregripTM Hook Clip Set systems using a 120 or 190 Series ScopeMeter.
• Soft Case

113
Current Clamps

i5s i50s i200 i200s i400 i400s

Specifications AC models
i5s i50s i200 i200s i400 i400s

Nominal current range(s 5A 3/30 AC RMS or DC 200 A 20 A 400 A 40 A


200 A 400 A

Continuous AC current range 0.01 A - 6 A 30 A cont. 50 A<10 sec 0.5 A - 200 A 0.1 - 24 A 5 A - 400 A 0.5 - 40 A
0.5 A - 200 A 5 A - 400 A

Highest current 70 A 30 A cont. 50 A<10 sec 240 A 240 A 1000 A 1000 A


Lowest measurable current 10 mA 10 mA 0.5 A 0.5 A 1A 0.5 A
Basic accuracy (48-65 Hz) 1) 1% ± 5% typical DC 1% + 0.5 A 1.5% + 0.5 A 2% + 0.15 2% + 0.15
to 100 kHz
Useable frequency 40 Hz - 5kHz DC to 50 MHz 40 Hz - 10 kHz 40 Hz - 10 kHz 45 Hz - 3 kHz 45 Hz - 3 kHz
Max. working voltage 600 V AC 300 V AC RMS or DC 600 V AC 600 V AC 1000 V 1000 V
Maximum conductor diameter 15 mm 5 mm 20 mm 20 mm 32 mm 32 mm

Output level(s) 400 mV/A 1/100 mV/A 1 mA/A 100 mV/A 1 mA /A 10 mV/A
10 mV/A 1 mV/A

Batttery, battery life External Power


Output cable (m) 2.5 2 1.5 2.0 1.5 2.5
Shrouded banana plugs O O
BNC connector • O O O
BNC to banana adapter included O
Safety CAT III, 600 V CAT I 300 V CAT III. 600 V CAT III, 600 V CAT III 1000 V / CAT III 1000 V /
CAT IV 600 V CAT IV 600 V
1)
Basic Accuracy: % reading + floorspec

i800 i1000s i2000 flex i3000s flex i3000s i6000s flex


i800 i10000s i2000 flex i3000s flex-24 i3000s i60000 flex-24
i3000s flex-36 i6000s flex-36
Nominal current range(s) 800 A RMS 10 A 20 A 30 A 30 A 60 A
100 A 200 A 300 A 300 A 600 A
1000 A 2000 A 3000 A 3000 A 6000 A AC
Continuous AC current range 0.1 A - 800 A RMS 0.1 A - 10 A 1 A - 20 A 1 A - 30 A 1 A - 30 A 1 A - 6000 A AC RMS
0.1 A - 100 A 2 A - 200 A AC RMS 2 A - 300 A AC RMS 1 A - 300 A
1 A - 1000 A 30 A - 2000 A 30 A - 3000 A 1 A - 2400 A
Highest current 1500 A 2000 A 2500 A AC RMS 3500 A AC RMS 4000 A 6000 A
Lowest measurable current 0.1 A 0.1 A 1A 1A 1A 1A
Basic accuracy (48-65 Hz) 1) 0.10% 1% + 1 A 1% 1% 2% + 2 A ± 1% of range
Useable frequency 30 Hz - 10 kHz 5 Hz - 100 kHz 10 Hz - 20 kHz (-3dB) 10 Hz - 50 kHz (-3dB) 10 Hz - 100 kHz 10 Hz to 50 kHz
Max. working voltage 600 V AC RMS or DC 600 V AC 600 V AC RMS 600 V AC RMS 600 V AC 600 V AC RMS or DC
Maximum conductor diameter 54 mm 54 mm 178 mm Flex-24 178 mm 64 mm Flex-24 170 mm
Flex-36 275 mm Flex-36 275 mm
Output level(s) 1 mA/A 100 mV/A 100 mV/A 100 mV/A 10 mV/A 50 mV/A
10 mV/A 10 mV/A 10 mV/A 1 mV/A 5 mV/A
1 mV/A 1 mV/A 1 mV/A 0.1 mV/A 0.5 mV/A
Batttery, battery life 200 hours 400 hours 400 hours
Output cable (m) 1.6 1.6 0.5 0.5 2.1 0.5
Shrouded banana plugs O O n/a
BNC connector O n/a O O O
BNC to banana adapter included n/a O O O
Safety CAT III, 600 V CAT III, 600 V CAT III, 600 V CAT III, 600 V CAT III, 600 V CAT III, 600 V

1)
Basic Accuracy: % reading + floorspec

114
Current Clamps

80i-110s i30 i30s i310s i410 i1010


Specifications AC/DC Models
80i-110s i30 i30s i310s i410 i1010
Measurement type Hall sensor Hall sensor Hall sensor AC/DC Hall sensor Hall sensor
Nominal current range(s), 10 A, AC/DC 20 A AC RMS or DC 20 A AC RMS or DC 30/300 A AC RMS 400 A, AC/DC 600 A, AC
100 A, AC/DC or 45/450 A DC 1000 A, DC
Continuous current range 0.1 A - 10 A AC/DC 30 A AC Peak 30 A AC Peak 100 mA - 300 A AC 1 A - 400 A AC/DC 1 A - 600 A, AC
1 A - 100 A AC/DC RMS or 450 A DC 1 A - 1000 A, DC
Highest current 140 A - 2 kHz 30 A AC Peak 30 A AC Peak 300 A AC RMS or 400 A 1000 A
450 A DC
Lowest measurable current 0.1 A 50 mA 50 mA 100 mA 0.5 A 0.5 A
Basic accuracy 1) 3% + 50 mA (@ 10 A) ± 1% of reading ±2 mA ± 1% of reading ±2 mA ±1% of reading 3.5% + 0.5 A 2% +0.5 A
Useable frequency DC - 100 kHz DC to 20 kHz (-0.5dB) DC to 100 kHz (-0.5dB) DC to 20 kHz DC - 3 kHz DC - 10 kHz
Zero error adjustment O manual adjust via manual adjust via Manual O O
thumbwheel thumbwheel
Max. working voltage 600 V 300 V AC RMS 300 V AC RMS 300 V AC RMS or DC 600 V 600 V
Maximum conductor diameter 11.8 mm 19 mm 19 mm 19 mm 30 mm 30 mm
2 x 25 mm 2 x 25 mm
Output level(s) 100 mV/A 100 mV/A 100 mV/A 10/1 mV/A 1 mV/A 1 mV/A
10 mV/A
Battery, battery life 9 V, 55 h 30 hours typical 30 hours typical 30 hours 9 V, 60 h 9 V, 60 h
Output cable length (m) 1.6 1.5 2 2 1.6 1.6
Shrouded banana Plugs O n/a O O
BNC connector O n/a O O
BNC to banana adapter included n/a O O
Safety CAT II, 600 V CAT III, 300 V CAT III, 300 V CAT III 300 V CAT III, 600 V CAT III, 600 V
CAT III, 300 V

1)
Basic Accuracy: % reading + floorspec

Current Clamp Compatibility Chart 190 Series/215C/225C


113/114/115/116/117

741B/743B/744
175/177/179

8845A/8846

430 Series

1577/1587
27II / 28II

83V/87V
187/189

287/289

123/124
8808A

77 IV

88V

43B
233

125

715

724

725

787

789
AC Models
i5s O O O
i200 4 O O O O O O O O O O O O O
i200s O O O O O O O O O O O O O O O O O O O O
i400 O O O O O O O O O O O O O
i410 Kit AC/DC Current Clamp i400s 2 2 2 2 2 2 2 2 2 2 2 O O O O O 2 2 2 2
(400A) with soft case i430 flex O
i1010 Kit AC/DC Current Clamp i800 4 O O O O O O O O O O O O O
(1000A) with soft case i1000s 2 2 2 2 2 2 2 2 2 2 2 O O O O 2 2 2 2
i2000 flex (new version) O O O O O O O O O O O 3 3 3 3 3 O O O
• Combination of current clamp with
i3000s O O O O O O O O O O O O O O O O O O O O
carrying case
i3000s flex O O O O O O O O O O O O O O O O O O O O
• Zipped soft case with moveable i6000s flex O O O O O O O O O O O O O O O O
divider AC/DC Models
• Soft case is large enough to hold a i30 O O O O O O O O O O O O O O
meter i30s O O O O O O O O O O O O O O O O
80i-110s 2 2 2 2 2 2 2 2 2 2 2 O O O O O O 2 2 2
i310s O O O O O O O O O O O O O O O O O O O O
i410 / i410 kit O O O O O O O O O O 3 3 3 O 1 1 1 O O O
i1010 / i1010 kit O O O O O O O O O O O 3 3 3 O 1 1 1 O O O
Other
90i-610s* 2 2 2 2 2 2 2 2 2 2 2 O O O 2 2 2 2
* For specifications of 90i-610s see page 113
1 For DC only
2 Requires PM 9081 (see page 76)
3 Requires PM 9082 (see page 76)
4 115, 117 only

115
All accessories have a one year warranty
Temperature Accessories

Contact Probes DMM Probes

80PK-22 SureGrip™ Immersion Probe 80PK-1 and 80PJ-1 Bead Probe 80AK-A Thermocouple Adapter
• Type-K thermocouple for use in liquids • 80PK-1: Type-K thermocouple for • Adapts Type-K thermocouple
and gels general purpose applications mini-connector to dual banana
• Measurement range: • 80PJ-1 operates with J-type plug inputs
-40 to 1090°C thermometers • Measurement range and
• Probe length: 21.3 cm • Measurement range: accuracy: probe dependent
-40 to 260°C • Suitable for low voltage applications
• Probe length: (below 30 V AC, 60 V DC)
1 m lead wire

80PK-24 SureGrip™ Air Probe 80BK-A Integrated DMM


• Type-K thermocouple for use in Probe
air and non-caustic gas measurements • Type-K thermocouple with
• Bead protected by standard banana jack
80PK-3A Surface Probe • Convenient one piece construction
perforated baffle • Type-K thermocouple for flat or
• Measurement range: • Compatible with DMMs
curved surfaces such as with temperature
-40 to 816ºC plates and rollers
• Probe length: 21.6 cm measurement functions
• Measurement range: • Measurement range:
0 to 260°C -40 to 260ºC
• Probe length:
9.5 cm
80TK Thermocouple Module
• Converts a DMM to
80PK-25 and 80PT-25 SureGrip™ a thermometer
Piercing Probe • For use with type-K
• 80PK-25: Type-K thermocouple suitable for thermocouples in low voltage
food industry, liquids and gels 80PK-8 / 80PK-10 Pipe Clamp applications (below
• 80PT-25 operates with T-type Temperature Probe 24 V AC, 60 V DC)
thermometers • Type-K thermocouple for New • Measurement range:
• Measurement range: fast temperature and -50 to 1000°C (probe dependent)
80PK-25: -40 to 350°C superheat measurements
80PT-25: -196 to 350°C of pipe surfaces
• Probe length: 10.2 cm • Durable ribbon sensor
• Measurement range: 80T-150UA Universal Temperature Probe
-29 to 149°C for pipe diameters • Compatible with
from 6.4 to 34.9mm (80PK-8) and Fluke DMM
32 mm to 64 mm (80PK-10) • High accuracy, fast
reading for low voltage
(below 24 V AC, 60 V DC)
applications
80PK-26 SureGrip™ General Purpose 80PK-9 and 80PJ-9 General
• Measurement range:
Probe Purpose Probe -50 to 150°C
• Type-K thermocouple with tapered tip • 80PK-9: Type-K thermocouple surface, • Output: 1 mV/°C or 1 mV/°F (switchable)
for use in air, non-caustic gas and air and non-caustic gases
surface applications • 80PJ-9 operates with
• Measurement range: J-type thermometers
-40 to 816ºC • Measurement range:
• Probe length: 21.2 cm -40°C to 260°C
• Probe length:
15.3 cm

80PK-27 SureGrip™ Industrial Surface 80PK-11 Velcro


Probe Temperature Probe
• Type-K thermocouple for surfaces • Type-K thermocouple
in rugged environment for hands free
• Durable ribbon sensor measurement of
• Measurement range: -127 HVAC temperature
to 600°C measuring
• Probe length: 20.3 cm applications SureGrip™ accessories are designed to
• Total length of cable: improve steadiness in s lippery hands.
1m (0.5m in cable, 0.5m in Rubber overmolded surfaces and finger-
Velcro cuff insulation material; Hytrel) hugging curves give the user a comfortable,
• Measurement range: -30ºC to 105ºC reliable grip on the accessory so they can
focus on making an accurate measurement.
116
Temperature Accessories

Other Temperature Accessories

80PR-60 RTD Temperature Probe 80CK-M & 80CJ-M type K & J Male Thermocouple Plug Kits
• For simulaneously taking contact and Mini-Connectors 700TC1
non-contact temperature • Isothermal screw A kit of 10 mini-plug
measurements with terminal for K or J connectors
Fluke 66 or 68 wire Type J (black), one
• Measurement range: • Suitable for up to Type K (yellow), one
-40 to 260°C 20 guage Type T (blue), one
thermocouple wire Type E (purple), one
• Color coded to Type R/S (green), one
industry standards Type B or CU (white), one
(K-yellow, J-black) Type L (J-DIN) (blue), one
• Two per package Type U (T-DIN) (brown), one
Type C (red), one
Type N (orange), one
New 80PK-EXT, 80PJ-EXT and 700TC2
80PT-EXT Extension Wire Kits A kit of 7 mini-plug connectors
• Extending and repairing J, K ot T-type Type J (black), two
80PK-18 Pipe thermocouple wires Type K (yellow), two
Clamp Temperature Probe Kit • Kit includes 3 meters of thermocouple wire Type E (purple), one
• 80PK-8 Pipe Clamp Temperature Probe and 1 pair of male/female mini-connectors Type T (blue), one
• 80PK-10 Pipe Clamp Temperature Probe • Maximum continuous exposure temperature: Type R/S (green), one
• Soft Case 260ºC
• 80PK-EXT is compatible
with K-type thermometers,
80PJ-EXT is designed for
J-type thermometers and
PT-EXT for T-type
thermometers

Temperature Probe Compatibility Chart


190 Series/225C/215C
113/114/115/116/117

8845A/8846A/8808A

741B/743B/744
51/52/53/54 II
120 Series
27II / 28II
175/177

287/289

566/568

705/707
66/68
1577

1587
77IV

83V

87V

88V

43B
179

233

561

714

715

724

725

787

789

Contact Probes
80PK-1 … 80PK-27 1 1 2 2 2 2 1 1 1 2 2 1 1 1 1 2 O O O 1 O 1 O O O 1 1
80PJ-1, 80PJ-9 O O O O O
80PT-25 1 O O O O O
DMM probes
80AK-A O3) O O O O O O O
80BK-A O3) O O O O O O O
80TK O O O O O O O O O O O O O
80T-150UA O O O O O O O O O O O O O O O O O
Miscellaneous
80CK-M 1 1 2 2 2 2 1 1 1 2 2 1 1 1 1 2 O O O 1 O 1 O O O 1 1
80CJ-M O O O O O
80PK-EXT4) 1 1 2 2 2 2 1 1 1 2 2 1 1 1 1 2 O O O 1 O 1 O O O 1 1
80PJ-EXT O O O O O
80PT-EXT O O O O O
700TC1, 700TC2 O O O O O
80PR-60 O
1) Requires 80TK
2) Requires 80AK
3) Fluke 116 only
4) Also requires 80CK-M

117
All accessories have a one year warranty
Cases and Holsters

Soft Cases
Zipped carrying cases protect your meter; most cases come with belt loops so your meter is
stored conveniently on your tool belt. C195
• Zipped carrying
case with storage
compartments
• Allows hand or
shoulder use
C789
• Large fabric carrying case
with 3 compartments,
C12A C23 C25 C33 C35 removable handle and
shoulder strap

C550 Tool Bag


• Steel reinforced frame
C570 C43 C50 C75 C90 • Rugged ballistic
cloth with heavy duty
hardware
• Large zippered storage
compartment with
25 pockets
• Weather resistant
• Carry all your tools to
C115 C116 C125/C781 C280 C345 the job

Cases & Holsters Compatibility Chart


333/334/335/336/337/902

190 Series/225C/215C
1503/1507/1577/1587
113/114/115/116/117

1735/1740 Series

712/714/715/717
43B/120 Series

741B/743B/744
51/52/53/54 II
83V/87V/88V
175/177/179

724/725/726
T100 Series

430 Series

570 Series
9040/9062
27II / 28II

63/66/68
287/289

321/322

353/355

566/568

705/707
77 IV

T50
233

922

971

561

718

787

789
T5

61
Soft Cases Size (HxWxD) mm
C12A 172 x 128 x 38 O O
C23 225 x 95 x 58 O O O O O O O
C25 218 x 128 x 64 O O O O O O O O O O O O O
C33 280 x 115 x 55 O O O O
C35 220 x 140 x 65 O O O O O O O O O O O O
C43 318 x 230 x 90 O O O O
C50 192 x 90 x 38 O O
C75 179 x 103 x 26 For multiple test leads and accessories
C90 205 x 90 x 72 O O O
C115 240 x 205 x 75 O O O O O O O O O O O
C116 240 x 230 x 65 O O O O O O O O O O O O O
C125 192 x 141 x 58 O O O O O O O O
C195 231 x 513 x 231 O O O
C280 230 x 185 x 65 O O O O O O O O O O O O O O O O
C345 240 x 360 x 200 For multiple test leads and accessories
C550 333 x 513 x 231 For multiple test leads and accessories
C570 240 x 160 x 61 O
C781 269 x 141 x 90 O O O O O O O O O
C789 308 x 256 x 77 O O O O O
Hard cases
C20 256 x 154 x 106
C100 397 x 346 x 122 O O O O O O
C101 305 x 360 x 105 O O O O O O O O O O O O O O O O O O O
C120 346 x 397 x 128 O
C190 410 x 474 x 135 O
C435 565 x 476 x 305 O O
C800 230 x 385 x 115 O O O O O O O
C1600 260 x 390 x 200 For multiple test leads and accessories
CXT80 28 x 32 x 13 O O O
CXT170 28 x 32 x 13 O O O O O O O
CXT280 28 x 32 x 13 O
Leather Cases
C510 287 x 179 x 106 O O O O O O O O O
C520A 256 x 154 x 106 O
Holsters
C10 154 x 77 x 45 O
H80M 190 x 95 x 43 O O O O
Other
H3 231 x 90 x 64 O O
H5 192 x 90 x 38 O
H6 302 x 178 x 57 O O O
118 Hanging Kit (see page 120)
ToolPak O O O O O O O O O O O O
Cases and Holsters

Hard Cases Holsters

C20 Meter Case C10 Meter Holster H3 Clamp Meter Holster


• Heavy duty case with • Snap-on yellow holster • Fabric holster absorbs
carrying handle and absorbs shocks and protects shocks and protects
accessories storage meter from rough handling meter from rough
compartment • Includes built-in stand and handling.
• Top cover snaps onto back to hanger loop • Built-in pocket for lead
serve as tilt stand storage
• Convenient belt-loop with snap
H80M Holster + Magnetic Hanger
• Snap-on yellow
C100 Meter and holster absorbs shocks H5 Electrical Tester Holster
Accessory Case and protects meter from • Rugged fabric holster includes flap for lead
• Tough polyprophylene case rough handling storage and built-in belt
• Magnet, hook and loop loop
straps • Fits Fluke T3 and T5
C101 Hard Case testers
• General purpose hanger
The hard case that fits all Fluke
industrial test tools. Configure
the diced foam interior to store
and protect what you need to
carry with you.
• Tough polyprophylene exterior shell
H6 Infrared Thermometer Holster
• Durable nylon holster
• Interior cavity measures
• For Fluke 63, 66 and 68 Infrared
Thermometers

C120 and C190 Cases


• Heavy duty cases with accessory
storage compartments

C435 Hard Rolling Case Leather Cases


• Watertight hard case
with rollers for 430 Series, C510 Leather Meter Case C520A Leather Tester Case
1735 and 1740 Series • Oiled genuine top grain cowhide • Oiled genuine top grain cowhide
Power Quality products and • Rugged construction with heavy duty • Oil tanned for long life
accessories. The stitching and reinforced rivets • Rugged construction with heavy duty
configurable foam securely • Large tool belt loop and stitching and reinforced rivets
holds any of these top flap to secure meter • Large tool belt loop and
instruments during transit. • Holds most Fluke DMMs, top flap to secure tester
Thermometers, and • Holds Fluke Electrical
Process Calibrators Testers
C800 Meter and Accessory Case
• Tough polyprophylene case
• Accessories and manual
compartments
• Detachable lid

C1600 Meter and Accessories Case


• Rugged molded plastic case
• Deep interior large enough to hold
and protect your tools
• Lift out tray keeps
everything organized
• Snap open compartment
on top of lid

CXT80, CXT170, CXT280 Rugged Pelican


Hard Case
• Unbreakable, watertight,
airtight, dustproof, chemical
resistant and corrosion proof
case
119
All accessories have a one year warranty
Software and other Accessories

Software FlukeView® Forms Hanging Kit


FlukeView Forms increases the power of your ToolPak (TPAK)
Fluke tool by enabling you to document, store The meter hanging solution
and analyze individual readings or series • Kit includes, universal hanger clips (2), hook
of measurements, then convert them into & loop straps (2 lengths) and strong magnet
professional-looking documents. FlukeView • Combine components to meet most hanging
Forms supports the following multimeters: needs

See page 118 for compatibility chart

FlukeView Forms Compatibility Chart


FVF Option Instrument Cable** Application Level
Software only upgrade, Any instrument that
FVF-UG No Cable included
supports Flukeview Forms Software
FVF-SC1 Fluke 53-II, 54-II, 87-IV*, 89-IV* Serial / IRDA FVF Full (includes Designer)
FVF-SC2 Fluke 280 Series, 789, 1550B, 1653B, 568,180 Series* USB / IR
FVF-SC4 Fluke 8808A, 8845A, 8846A, 45*, 975 USB / Serial
FVF-BASIC Fluke 280 Series, 789, 1550B, 1653B, 180 Series* USB / IR
FVF BASIC
FVF-SC5 8808A, 8845A, 8846A, 45* USB / Serial
* Obsolete
** USB cables are not supported for Microsoft Windows NT 4.0

IR189USB
IR to USB interface cable
(included with FVF-SC2 and FVF-Basic)
• For customers who want to upgrade from
their existing RS232 cable
• Small adapter to connect the cable to the 189,
287, 289, 1653B or the 1550B is included.
• CD-Rom with drivers for use with older Fiber Optics
versions of FVF-SC1 included.
FOM Fiber Optic Meter
The Fluke Fiber Optic Meter (FOM) helps you
test and maintain fiber optic cables without
having to buy a whole new
meter. Plug the FOM
directly into any DMM with
Make extended logging easier a mV dc function and a
10 MΩ input impedance and
BP189 High Capacity Battery Enclosure quickly and accurately
(for Fluke 180 Series DMM) verify fiber optic cable system loss. Light
• Expand the battery life of your Fluke sources and patch cords sold separately.
187/189 up to 450 hours (over two weeks of
continuous use).
• Houses 4 ‘C’ cell batteries. FOS 850 & FOS 850/1300
• CAT III 1000 V, CAT IV 600 V
Fiber Optic Light Sources
Batteries and meter sold separately
A variety of light sources allow you to test
different cable lengths.

120
All accessories have a one year warranty
Other Accessories

Lights Stray Voltage Adapter High Voltage Probes

L200 Probe Light SV225 Stray Voltage Adapter 80K-6 and 80K-40
• Attaches to any Fluke test probe Stray voltage can appear in A high voltage probe that
• Bright white LED electrical installations, due to allows a multimeter to
• 120 hours of battery life the capacity between wires. measure up to 6,000V or
This may result in erroneous 40,000V respectively.
readings on high impedance Intended for low energy applications only
meters.

The SV225 solves this without


compromising safety.
L205 Mini Hat Light • On energized wires, the meter will indicate
Rugged high-intensity
the real voltage.
Xenon worklight
• On non-energized circuits the meter
• Attaches to a baseball cap
will read close to zero (even if there
• Includes a hat clip
are stray voltages).
• Includes two AAA
• It can be used with all modern
batteries
meters with standard input spacing.
• Waterproof
• Rated CAT III 1000 V, CAT IV 600 V

L206 Deluxe LED Hat Light TL225 SureGrip™ Stray Voltage Adapter
(hard hat not included) Test Lead Kit
Attach it to a hard hat, Kit includes:
a baseball cap, or even a • SV225 Stray Voltage
panel door for all the light Eliminator
you need. • TL224 SureGrip™
• 3 super bright white LEDs Silicone Test Lead Set
– never burn out (right to straight)
• Special hard-hat attachment included • TP220 SureGrip™ Test
• 40-hour battery life Probe Set
• Includes three AAA batteries • C75 Accessory Case

L210 Probe Light +


Probe Extender
• Includes L200 Probe Light
and TP280 Test Probe
Extenders
• 20 cm probe extenders
keep hands away from
live circuits
• Extender fits between modular test probe Meter Cleaners
and test lead (total reach 30 cm)
MC6 MeterCleaner™ Wipes (6-pack)

MC50 MeterCleaner™ Wipes


(50-pack)
• Pre-moistened wipe removes dirt, oil and
grease
• One wipe easily cleans one meter
• Safe on rubber, plastic and for environment
(non-toxic)

121
All accessories have a one year warranty
Product Quick Find List

Model Page Model Page Model Page Model Page Model Page Model Page
Fluke 1AC I 32 Fluke 707 Ex 99,107 Fluke 8846A/SU 23 700PA4 Ex 102,107 EI-1623 40 PV350 113
Fluke 1AC II 32 Fluke 712 96 Fluke 9040 33 700PA5 102 EI-1625 40 RPM80 113
Fluke 1AC II 5PK 32 Fluke 714 96 Fluke 9062 33 700PA6 102 EI-162BN 40 RS200 76
Fluke 27II 21 Fluke 715 99 Fluke 9142-X 97 700PCK 102 ES-162P3 40 SCC120 73
Fluke 28II 21 Fluke 717 1G 98 Fluke 9143-X 97 700PD2 102 ES-162P4 40 SCC128 113
Fluke 43B 81 Fluke 717 100G 98 Fluke 9144-X 97 700PD3 102 ES165X (1653) 48 SCC190 75
Fluke 51 II 55 Fluke 717 1000G 98 Fluke CO-205 69 700PD4 102 EXTL100 48 SCC191 75
Fluke 52 II 55 Fluke 717 1500G 98 Fluke CO-220 69 700PD5 102 FLK-075-CLKT 59 SCC198 113
Fluke 53 II 55 Fluke 717 30G 98 Fluke Norma 4000 89 700PD6 102 FLK-100-CLKT 59 SM100 32
Fluke 54 II 55 Fluke 717 300G 98 Fluke Norma 5000 89 700PD7 102 FLK80P1 56 SM200 32
Fluke 61 52 Fluke 717 500G 98 Fluke RLD2 70 700PRV 102 FLK80P3 56 SM300 32
Fluke 62/322/1AC Kit 5, 52 Fluke 717 3000G 98 Fluke T5-600 31 700PTP 102 FLK-LENS-TELE1 61-63 SP1000 48
Fluke 62 52 Fluke 717 5000G 98 Fluke T5-600/62/1AC Kit 700PV3 102 FLK-LENS-WIDE 61-63 SP-Scan-15 48
Fluke 63 52 Fluke 718 Ex 98,107 5, 31 700PV4 102 FLK-Ti-SPB3 61-63 SV225 121
Fluke 66 52 Fluke 718 1G 98 Fluke T5-H5-1AC Kit 5, 31 700SW 93 FOM 120 SW90W 75
Fluke 68 52 Fluke 718 30G 98 Fluke T5-1000 31 700TC1 117 FOS 850 120 Ti-Car Charger 60-63
Fluke 771V 20 Fluke 718 100G 98 Fluke T50 30 700TC2 117 FOS 1300 120 Ti-SBC3 61-63
Fluke 83V 17 Fluke 718 300G 98 Fluke T100 30 884X-case 18 FS17XX 88 Ti-TRIPOD 60-63
Fluke 87V 17 Fluke 719 30G 98 Fluke T120 30 884X-512M 18 FTP SureGrip fused test Ti-Visor 60-63
Fluke 87V Ex 107 Fluke 719 100G 98 Fluke T140 30 975CK 67 probes 111 TL175 112
Fluke 87V/E2 Kit 4 Fluke 724 95 Fluke Ti9 60 975R 67 FTPL SureGrip fused test TL27 110
Fluke 87V/i410 4 Fluke 725 94 Fluke Ti10 60 975VP 67 probes with leads 111 TL28A 113
Fluke 88V/A 22 Fluke 725 Ex 94,107 Fluke Ti25 61 2373-LPRT 56 FVF- Basic 120 TL2X4W-PT-II 23-24
Fluke 113 19 Fluke 726 94 Fluke Ti32 61 2384P 56 FVF-SC1 120 TL2X4W-TWZ 23-24
Fluke 114 19 Fluke 741B 93 Fluke TiRx 62 2384T 56 FVF-SC2 120 TL40 109
Fluke 115 19 Fluke 743B 93 Fluke TiR 62 5616-12-P 56 FVF-SC4 120 TL71 110
Fluke 116 19 Fluke 744 93 Fluke TiR1 63 5615-9-P 56 FVF-SC5 120 TL75 110
Fluke 117 19 Fluke 771 100 Fluke TiR32 63 5610-9-P 56 FVF-UG 120 TL76 110
Fluke 117/322 Kit 4 Fluke 772 100 Fluke VR1710 79 AC72 112 GPS430 83 TL80A 109
Fluke 123 73 Fluke 773 100 80AK-A 116 AC87 112 H3 119 TL81A 109
Fluke 123/S 73 Fluke 787 101 80BK-A 116 AC89 112 H5 119 TL82 113
Fluke 124 73 Fluke 789 101 80CJ-M 117 AC220 112 H6 119 TL220 110
Fluke 124/S 73 Fluke 810 104 80CK-M 117 AC280 112 H80M 119 TL221 110
Fluke 125 73 Fluke 902 26 80i-110s 115 AC283 112 H900 110 TL222 110
Fluke 125/S 73 Fluke 922 68 80K-40 121 AC285 112 i1A/10A Clamp PQ3 88 TL223 110
Fluke 175 18 Fluke 922/Kit 68 80K-6 121 ACC-T5-Kit 111 i1A/10A Clamp PQ4 88 TL224 110
Fluke 177 18 Fluke 971 69 80PJ-1 116 AN5 51 i5A/50A Clamp PQ3 88 TL225 121
Fluke 179 18 Fluke 975 67 80PJ-9 116 APP1000/APP2000 48 i5A/50A Clamp PQ4 88 TL238 110
Fluke 179/TPAK kit 4 Fluke 975V 65 80PJ-EXT 117 AS200-G 76 i5s 114 TL910 109
Fluke 179/EDA2 Kit 4 Fluke 983 70 80PK-1 116 AS200-R 76 i20/200A Clamp PQ3 88 TL930 109
Fluke 179/MAG2 Kit 4 Fluke 1503 38 80PK-3A 116 BDST3 48 i20/200A Clamp PQ4 88 TL932 109
Fluke 179/61 Kit 4 Fluke 1507 38 80PK-8 116 BDST4 48 i30 115 TL935 109
Fluke 192C 75 Fluke 1523 56 80PK-9 116 BE9005 94 i30s 115 TL940 109
Fluke 192C/S 75 Fluke 1523-P1 56 80PK-10 116 BP120MH 76 i50s 114 TL950 109
Fluke 196C 75 Fluke 1524 56 80PK-11 116 BP189 120 i200 114 TL960 109
Fluke 196C/S 75 Fluke 1524-P1 56 80PK-18 117 BP190 76 i200s 114 TL970 109
Fluke 199C 75 Fluke 1550B 39 80PK-22 116 BP880 113 i310s 115 TLK-220 110
Fluke 199C/S 75 Fluke 1577 37 80PK-24 116 BP881 113 i400 114 TLK-225 111
Fluke 215C 75 Fluke 1587 37 80PK-25 116 BP980 109 i400s 114 TLK281 113
Fluke 215C/S 75 Fluke 1587/ET 5, 36 80PK-26 116 BP7235 102 i410 115 TLK282 113
Fluke 225C 75 Fluke 1587/MDT 5, 36 80PK-27 116 C10 118 i410 Kit 115 TLK287 109
Fluke 225C/S 75 Fluke 1587T 37 80PK-EXT 117 C12A 118 i430-flex-4pk 88 TLK289 111
Fluke 233 16 Fluke 1621 41 80PR-60 117 C20 119 i5sPQ3 88 TLK290 111
Fluke 287 15 Fluke 1623 40 80PT-EXT 117 C23 118 i800 114 TLK291 111
Fluke 289 15 Fluke 1623 Kit 40 80T-150UA 116 C25 118 i1000s 114 TP1 111
Fluke 287/FVF 5 Fluke 1625 40 80TK 116 C280 118 i1010 115 TP2 111
Fluke 289/FVF 5 Fluke 1625 Kit 40 90i -610s 113 C33 118 i1010 Kit 115 TP4 111
Fluke 321 27 Fluke 1630 42 700HTH 102 C345 118 i2000flex 114 TP38 111
Fluke 322 27 Fluke 1651B 44 700HTP 102 C35 118 i3000flex 114 TP40 113
Fluke 333 26 Fluke 1652B 44 700ILF 102 C43 118 i3000s 114 TP74 111
Fluke 334 26 Fluke 1653B 44 700LTP 102 C50 118 i6000s flex 114 TP80 111
Fluke 335 26 Fluke 1735 84 700P00 102 C75 118 IP-200-UK 59 TP81 113
Fluke 336 26 Fluke 1743 85 700P01 102 C90 118 IR 189USB 120 TP82 113
Fluke 337 26 Fluke 1743 Basic 85 700P01 Ex 102,107 C100 119 L200 121 TP84 113
Fluke 345 80 Fluke 1744 85 700P02 102 C101 119 L205 121 TP88 113
Fluke 353 28 Fluke 1744 Basic 85 700P03 102 C115 118 L206 121 TP220 111
Fluke 355 28 Fluke 1745 85 700P04 102 C116 118 L210 121 TP912 109
Fluke 360 29 Fluke 1750 86 700P05 102 C120 119 L215 111 TP920 109
Fluke 411D/62 Kit 5, 65 Fluke 1750/B 86 700P05 Ex 102,107 C125 118 LVD1 32 TPAK 120
Fluke 411D 65 Fluke 1760 87 700P06 102 C190 119 LVD2 32 TPS Clamp 50A / 5A 87
Fluke 416D 65 Fluke 1760 Basic 87 700P06 Ex 102 C195 118 MC6 121 TPS Clamp 200A / 20A 87
Fluke 421D 65 Fluke 1760TR 87 700P07 102 C435 119 MC50 121 TPS FLEX 18 87
Fluke 434 83 Fluke 1760TR Basic 87 700P08 102 C510 119 MTC1363 (UK) 48 TPS FLEX 24 87
Fluke 434 Basic 83 Fluke 2042 34 700P09 102 C520A 119 MTC77 (Europa) 48 TPS FLEX 36 87
Fluke 434 LOG 83 Fluke 2042T 34 700P09 Ex 102,107 C550 118 OC4USB 76 TPS Shunt 5 A 87
Fluke 435 83 Fluke 4180 97 700P22 102 C570 118 PAC91 76 TPS Shunt 20 MA 87
Fluke 435 Basic 83 Fluke 4181 97 700P23 102 C781 118 PASS560R 48 TPS Voltprobe 1 KV 87
Fluke 561 54 Fluke 4180-CASE 97 700P24 102 C789 118 PM8918/301 76 TPS Voltprobe 10 V 87
Fluke 566 53 Fluke 4180-DCAS 97 700P24 Ex 102,107 C800 119 PM9080 76 TPS Voltprobe 100 V 87
Fluke 568 53 Fluke 6200 46 700P27 102 C1600 119 PM9081 76 TPS Voltprobe 400 V 87
Fluke 572 51 Fluke 6500 46 700P27 Ex 102,107 CXT80 119 PM9082 76 TPS Voltprobe 600 V 87
Fluke 572CF 51 Fluke 8808A 24 700P29 102 CXT170 119 PM9090 76 VPS40 76
Fluke 574 51 Fluke 8808A/SU 24 700P29 Ex 102,107 CXT280 119 PM9091 76 VPS210-R/G series 76
Fluke 574CF 51 Fluke 8808A/TL 24 700P30 102 DMS 0100/INST 48 PM9092 76
Fluke 700 Ex 107 Fluke 8845A 23 700P31 102 DMS 0702/PAT 48 PM9093 76
Fluke 705 99 Fluke 8845A/SU 23 700PA3 102 DMS COMPL PROF 48 PM9094 76
122 Fluke 707 99 Fluke 8846A 23 700PA4 102 DP120 76 PT12 68
Fuse and Warranty Information

Product Warranty
Each Fluke product is warranted to be free from defects
in material and workmanship under normal use and
service, for the warranty period listed unless local law
requires a longer period. The warranty period is listed
in the ordering information section of the product
specification and begins on the date of shipment.
This warranty extends only to the original buyer or
end-user customer of a Fluke authorized reseller, and
does not apply to fuses, disposable batteries or to any
product which, in Fluke’s opinion, has been misused,
altered, neglected or damaged by accident or abnormal
conditions of operation or handling. Fluke warrants that
software will operate substantially in accordance with its
functional specifications for 90 days and that it has been
properly recorded on non-defective media. Fluke does
not warrant that software will be error free or operate
without interruption.

Lifetime Warranty
Each Fluke 20, 70, 80, 170, 180 and 280 Series DMM
purchased after October 1, 1996 will be free from defects
in material and workmanship for its lifetime. This
warranty does not cover fuses, disposable batteries and
damage from accident, neglect, contamination, misuse or
abnormal conditions of operation or handling, including
overvoltage failures caused by use outside the DMM’s
specified rating, or normal wear and tear of mechanical
components. This warranty covers the original purchaser
Fuse Replacement Information only and is not transferable. For ten years from the
date of purchase, this warranty also covers the LCD.
A V IR
Size Part nr Thereafter, for the lifetime of the DMM, Fluke will replace
in mm qty 1
the LCD for a fee based on then current component
63mA (slow) 250V 6.35x32 163030
125mA (slow) 250V 6.35x32 166488
acquisition costs.
250mA (slow) 250V 6.35x32 166306 To establish original ownership and prove date of
315 mA 1000V 10KA 6.35x32 2279339 purchase, please complete and return the registration
440mA 1000V 10kA 10.3x34.9 943121 card accompanying the product.
500mA 250V 1500A 5x20 838151
630mA 250V 1500A 5x20 740670
1A 600V 10kA 10.3x34.9 830828
1A 500V 50kA 6.35x 32 2530449 Service
1.25A 600V 6.35x32 2040349
3.15A 500V 6.35x32 2030852 Fluke will, at its discretion, repair at no charge, replace
11A 1000V 17kA Replaced by 11A, 1000V, 20kA fuse; 803293 or refund the purchase price of a defective product
11A 1000V 20kA 10.3x38.1 803293 purchased through a Fluke authorized sales outlet and at
15A 600V 100kA 10.3x38.1 892583 the applicable international price. Fluke reserves the right
20A 600V Replaced by 15A, 600V, 100kA fuse; part nr. 892583 to charge for importation costs of repair/replacement
parts if product purchased in one country is sent for
repair elsewhere.
See the back of your Fluke test tool or user manual for the fuses installed.
For manuals check the Fluke website in the product section. Send defective product with a description of the
For Fuse Replacement Guide check the Fluke website in the service section. problem to the nearest Fluke Authorized Service Center,
postage and insurance prepaid. Fluke will pay return
transportation for product repaired or replaced in-
warranty. Before making any non-warranty repair, Fluke
will estimate cost and obtain authorization, then invoice
you for repair and return transportation.

THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER


WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR
PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT
LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR
CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING
LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY.
AUTHORIZED RESELLERS ARE NOT AUTHORIZED TO
EXTEND ANY DIFFERENT WARRANTY ON FLUKE’S
BEHALF.

Since some states do not allow the exclusion or


limitation of an implied warranty or of incidental or
consequential damages, this limitation of liability may 123
not apply to you.
Fluke Precision
Measurement products

Total Solutions in Precision


Measurement Catalog
A variety of products covering DC/LF
Electrical Calibration, Power Calibration,
Calibration Software, Pressure Calibration,
Time and Frequency, Temperature and
Humidity Calibration including Hart Scientific, as well as
Data Acquisition and Gener al Purpose Test products like
arbitrary waveform generators and VXI products.

To get a copy, please click “Request a catalog” on your local


Fluke web site.

About Fluke
Networks
Fluke Networks provides innovative
solutions for the installation and
certification, testing, monitoring and
analysis of copper, fiber and wireless
networks used by enterprises and
telecommunications carriers.

The company’s comprehensive line of


Network SuperVision™ Solutions provide
network installers, owners, and maintainers
with superior vision, combining speed,
accuracy and ease of use to optimize
network performance. Headquartered
in Everett, Washington, the company
distributes its products in more than 50
countries. More information can be found
by visiting Fluke Networks’ Web site at
www.flukenetworks.com

Fluke. Keeping your world


up and running. ®
124