Maestro 81 20 Gearless Eng 1
Maestro 81 20 Gearless Eng 1
Maestro 81 20 Gearless Eng 1
LINE
3X380 V AC
L1 L2 L3 N PE
2 4 6 8
F2-16A
B C
1 3 5 7 9
MSS-1 F3-10A
40A
2 4 6 8 10
A1
3
KSL-1
220V AC
4
A2
1 3 5 7
F1 SBL-1
25A
2 4 6 8
3 4
INT-C / 12.0
L1 L2 L3 N LP2 LP1 PE NF 1F
INT-B / 12.0
1F / 2.0
NF / 2.0
PE / 2.0
LP1 / 2.0
LP2 / 2.0
N / 2.0
L3 / 2.0
L2 / 2.0
L1 / 2.0
12V+ / 11.0
Supply terminals of rescue system ALM / 11.0
power device output (LP1-LP2) must be 1 / 2.0
passed from main switch contacts (NO). SL-n
MP / 2.0
220V AC
First Drawing Modification Board Series ELECTRIC Customer Serial Number Confirm : MACHINE ROOM CONNECTIONS Page Number 1
Date 29.03.2018 Date 27.03.2019 Project No AE-MAESTRO 01
Draw Hakan USTA Draw Hakan USTA Form No F/7.5.5.02.104 Model Referance Number of Pages 18
0 1 2 3 4 5 6 7 8 9
FKL-6A
1.9 / 1F 1 / 11.0
1F
1.9 / NF MP / 11.0
NF
1.9 / MP
1.9 / 1 FTR1-4A
1.9 / LP2 DR2 / 3.0
1.9 / LP1 DR3 / 3.0
-F4-25A
6 5
1.9 / L3
L3
4 3
1.9 / L2
L2
2 1
1.9 / L1
L1
1.9 / N
N
1.9 / PE PE / 4.0
PE
FTKR-30mA
25A
TRF-80W
1 3 220V 230V F110-1A
IΔ
FUTKR
30mA 220V 2 1
25A
IΔ 110 / 3.0
2 4 0V 0V 4 3
150 / 4.0
SMPS-1
24V DC/min. 50W
L V+
I 100 / 4.0
AC
N V-
PE 1000 / 4.0
PE NUP LUP PE
BRAC / 6.0
UN UP L1 L2 L3 1 3
LINE KF
/7.4 2 4
P+ N
VARISTOR
Braking
PE NUP LUP LP NP
Resistor AE-MAESTRO L
AC AC
LINE LOAD DB MOTOR
PE RD1
BRAKE
UPSLIFT ENCODER U V W
KF
5 6
840P / 3.0
BAT- BAT+
/7.4
2000P / 3.0
BR2 / 4.0
BR1 / 4.0
T2 / 5.0
T1 / 5.0
BR2 BRC BR1 T2 T1
FBAT-25A
PE P2 P1
NC2 Com NC1
U V W
G Θ
PG PTC
U1 V1 W1
Motor
Thermistor
5x12V=60V - + M
3~
Brake Monitoring
Battery Group MOTOR 3x380V AC PE
Contacts
12V 7Ah
First Drawing Modification Board Series Customer Serial Number Confirm : POWER CONNECTIONS Page Number 2
Date Date 27.03.2019 Project No
Draw Draw Form No Model Referance Number of Pages 18
0 1 2 3 4 5 6 7 8 9
AC
BRD
BS BB1
2.1 2.2
BB2
3.1 3.2
AC AC
OR 1.3 1.4
(RD7)
2.3 2.4
VARISTOR
OR Switch Position
1-0-2 3 3
0-Normal
1-Test
OR
Switch 4 4
2-Reset
/3.2 /3.1
BS : Mechanical brake test and rescue activation shalter.
2000 (B) BB1 : Mechanical brake test and rescue activation button 1.
2000 (A)
840 (B)
840 (A)
First Drawing Modification Board Series Customer Serial Number Confirm : UPS BRAKE Page Number 3
Date Date 11.04.2019 Project No
Draw Draw Form No Model Referance Number of Pages 18
0 1 2 3 4 5 6 7 8 9
CNT / 6.0
2.9 /PE PE / 11.0
3.9 / DR2 DR2 / 6.0
3.9 / DR3 DR3 / 17.0
2.9 / 100 100 / 5.0
2.9 / 1000 1000 / 5.0
2.9 / 150 120 / 8.0
125 / 8.0
130 / 8.0
135 / 9.0
140 / 8.0
151 / 6.0
ML1 / 13.0
ML2 / 13.0
SFR / 6.0
31 BRK / 7.0
KF
/7.4 32
100 1000 PE CNT CNN 150 120 125 130 135 140 151 ML1 ML2 S11 S14 S21 S24 S31 S34
S41 S44 S51 S54 S61 S64 GS GS1 VC VC1 B- B+ A+ A- CH1 CL1 CL0 CH0
CH0 / 5.0
CL0 / 5.0
CL1 /
CH1 /
VC1 / 6.0
VC / 6.0
GS1 / 6.0
GS / 6.0
2.9 / BR1
2.9 / BR2
First Drawing Modification Board Series Customer Serial Number Confirm : MAINBOARD CONNECTIONS Page Number 4
Date Date 27.03.2019 Project No
Draw Draw Form No Model Referance Number of Pages 18
0 1 2 3 4 5 6 7 8 9
I16
I15
H01-INPUT DEFINE
I14
I17: 2/870
I18: 9/551 I13
I19: 8/550
I9
12 / 15.0
12
39 / 15.0
39
32 / 15.0
32
31 / 15.0
31
SC
*SC : Signal Common Input
C D E F G - 1x
C0 C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 A B
G4 G3 G2 G1 G0 2G 2BC
2BC / 15.0
2G / 15.0
G / 15.0
F / 15.0
E / 15.0
D / 15.0
C / 15.0
B / 15.0
A / 15.0
C15 / 15.0
C1 / 15.0
C0 / 15.0
First Drawing Modification Board Series Customer Serial Number Confirm : TERMINAL CONNECTIONS Page Number 5
Date Date 27.03.2019 Project No
Draw Draw Form No Model Referance Number of Pages 18
0 1 2 3 4 5 6 7 8 9
2.9 / BRAC
4.9 / CNT
4.9 / DR2 DR2 / 17.0
SF11 SF12 R1-11 R1-14 R2-11 R2-14 R1-21 R1-24 R2-21 R2-24 SFR 151 100 1000 GS GS1 VC VC1
41 11 11 21 21 31 31
SFR1 SFR1 SFR2 SFR1 SFR2 A1 A1 SFR2 SFR1
/6.5 42 /6.5 14 /6.5 14 /6.5 24 /6.5 24 SFR1 SFR2 /6.5 34 /6.5 34
A2 A2
41
SFR2
11 14 /6.2 11 14 /6.3
/6.5 42
21 24 /6.3 21 24 /6.4
31 34 /6.7 31 34 /6.6
41 42 /6.1 41 42 /6.1
SER
BOARD
First Drawing Modification Board Series Customer Serial Number Confirm : SER BOARD CONNECTIONS Page Number 6
Date Date 27.03.2019 Project No
Draw Draw Form No Model Referance Number of Pages 18
0 1 2 3 4 5 6 7 8 9
4.9 / BRK
A1 C
KF
220V AC A2 R
CONTACTOR
6.9 / 151
1 2 /2.6
3 4 /2.6
6 5 /2.7
31 32 /4.3
First Drawing Modification Board Series Customer Serial Number Confirm : CONTACTOR CONNECTIONS Page Number 7
Date Date 27.03.2019 Project No
Draw Draw Form No Model Referance Number of Pages 18
0 1 2 3 4 5 6 7 8 9
S-BPS
BYPASS
0-NORMAL
1 2 0
3 4 0
DS-1 5 6 1
DS-2 7 8 2
DS-3 9 10 3
! ! !
DS-1 DS-2 DS-3 S-BPS: Bypass switch.
/9.7 /9.8 /9.9
0 0: Bypass switch Normal Position.
S-BPS S-BPS S-BPS
BYPASS S-BPS 1 DS-1: Bypass Contact of Semi Automatic Landig Door Contacts or
BYPASS BYPASS Automatic Landing Door (Door-B) Lock Contacts.
BYPASS
0-NORMAL 2 DS-2: Bypass Contact of Semi Automatic Landig Door Locking Contacts or
1-DS1 3-DS3
1 2 2-DS2 Automatic Landing Door (Door-A) Lock Contacts.
0 1 2 1 2
0 1 2 0
0 3 DS-3: Bypass Contact of, Automatic Car Door Contacts (Door-A and Door-B).
3 4 3 4 3 4
0 0 3 4 0
0
5 6 5 6
5 6 1 5 6 1
1 1
7 8
7 8 7 8 7 8 2
2 2 2
9 10
9 10 9 10
3 3
3 9 10
3
First Drawing Modification Board Series Customer Serial Number Confirm : BYPASS CIRCUIT CONNECTIONS Page Number 8
Date Date 27.03.2019 Project No FUL AUTOMATIC DOOR (FOR ONE CAR DOOR)
Draw Draw Form No Model Referance Number of Pages 18
0 1 2 3 4 5 6 7 8 9
8.9 / 130
8.9 / 125
8.9 / 120
5.9 /550 871 /
5.9 / 551 511 /
5.9 / 870 510 /
To KDM
SB03
Box
EED SB01 3 4
SS55
SB02 SB04
1.3 1.4
2 1 2.3 2.4 3 4 3 4
1.1 1.2
8.9 / 116A ! ! !
8.9 / 116
DS-1 DS-2 DS-3
/8.1 /8.2 /8.3
3.9 / 110
110 111 112 113 114 115 116 117 117A 118 118A 119 120 125 130 135 140
12
12 1.3 1.4 1 2
First Drawing Modification Board Series Customer Serial Number Confirm : SAFETY LINE CONNECTIONS Page Number 9
Date Date 27.03.2019 Project No FULL AUTOMATIC DOOR
Draw Draw Form No Model Referance Number of Pages 18
0 1 2 3 4 5 6 7 8 9
Only For
Machine Roomless
Application
ICM
SFC SFB SFA RSB
SDB
141
First Drawing Modification Board Series Customer Serial Number Confirm : SAFETY LINE CONNECTIONS Page Number 10
Date Date 5.04.2019 Project No FULL AUTOMATIC DOOR
Draw Draw Form No Model Referance Number of Pages 18
0 1 2 3 4 5 6 7 8 9
2.9 / 1 1 / 12.0
2.9 / MP MP / 14.0
6.9 / 100 100 / 12.0
9.9 / 1000 1000 / 12.0
5.9 / CL0 CL0 / 12.0
5.9 / CH0 CH0 / 12.0
4.9 / PE PE / 17.0
UBL / 14.0
C12V / 17.0
SCL / 17.0
35 / 12.0
409 416 C12V2 / 17.0
Cabin SCL2 / 17.0
CALLS
PE
H01- INPUT DEFINE 10
N1: 1/869 CH CL GND V+ 409 410 411 412 413 414 415 416 CM5 R5 CM4 R4 CM3 R3 C4 CM1 K15-B / 17.0
OUTPUTS
N11: FREE R9
N2: 7/501 N12: 32/KL2 2G G F E D C B A DISP (O4)
N3: 6/500 H02- OUTPUT DEFINE R1 K3-B / 17.0
N13: 29/K22 G0 G1 G2 31 32 39 35 R1: 60/Second door close command
N4: 16/804 N14: 30/DT2 OUT
Set parameter B-30 for Car display outputs R2: 61/Second door open command Optional R2 K5-B / 17.0
1 N5: 22/KL1 N15: 34/FT2
B-30 Car display output R3: 28/Overload lamp
N6: 18/K20
2
N7: 19/DTS
N8: 20/FOT
N16: 33/K2C
0- 7 Segment
1- Gray code
SCB R4: 55/Slow close-1
R5: 62/Bypass warning
DOOR
KK/K3 K3-A / 17.0
N9: 23/K1C INPS 2- Binary code Serial Communication R9: 56/Slow close-2
SIGNALS KO/K15 K15-A / 17.0
N10: 28/DTP Optional 3- 7 Segment+Arrow Cabin Board KA/K5 K5-A / 17.0
I-BUTTON INPUTS (I1) (I2) (I3) (I4) CALLS
IB+ IB- N1 N2 N3 N4 N5 N6 N7 N8 N9 N10 N11 N12 N13 N14 N15 N16
401 402 403 404 405 406 407 408 - BAT + - EL + - SPK + - AB + - 12V +
First Drawing Modification Board Series Customer Serial Number Confirm : INSPECTION BOX CONNECTIONS Page Number 11
Date Date 27.03.2019 Project No
Draw Draw Form No Model Referance Number of Pages 18
0 1 2 3 4 5 6 7 8 9
1
11.9 / 1 / 17.0
11.9 /CFAN
11.9 / 100 100 / 13.0
11.9 / 1000 1000 / 13.0
11.9 /CL0
11.9 / CH0
1.9 / INT-B
1.9 / INT-C
11.9 / 12V-
11.9 / 12V+ 12V+ / 13.0
11.9 /35
11.9 / K22
11.9 / DT2
11.9 /K20
11.9 / DTS
11.9 / ALM
11.9 / EL+
11.9 / EL-
CH CL GND V+
400-n Cabin
Display
Indicator
11.9 / 408 IKB-n CDH
Cabin
CALLS NO C
IKB-8
NO C
CRL-8
- + B-INT
24V DC max.1W
C-ALM NO C
K20 K22
NO C NO C NO C
ILP
+ -
K20-LP K22-LP
IKB-2 DTS - + DT2 - +
12V DC
24V DC C-ALP 24V DC
NO C NO C + - NO C
OVLP
CRL-2 DTS-LP
C-EL 12V DC DT2-LP - +
- + - + - + - + BUT + - C B
+ - NO C
24V DC 12V Phone
24V DC max.1W 24V DC 12V DC 24V DC 24V
R-FAN
IKB-1 - +
First Drawing Modification Board Series Customer Serial Number Confirm : C.O.P. CONNECTIONS Page Number 12
Date Date 5.04.2019 Project No
Draw Draw Form No Model Referance Number of Pages 18
0 1 2 3 4 5 6 7 8 9
4.9 / MKD
4.9 / 818
4.9 / 817
D1 D2
1N4007 1N4007
First Drawing Modification Board Series Customer Serial Number Confirm : MAGNETIC SWITCH CONNECTIONS Page Number 13
Date Date 27.03.2019 Project No
Draw Draw Form No Model Referance Number of Pages 18
0 1 2 3 4 5 6 7 8 9
14.9 / 1 1 / 14.0
11.9 / MP MP / 17.0
13.9 / 100 100 / 15.0
13.9 / 1000 1000 / 15.0
11.9 / UBL
13.9 / 12V+
13.9 / ML1
13.9 / ML2
FD+ FD-
UBL
MKD/ML2 ML1 FD- FD+ +12V 1000 100 FD
+ -
12V DC 24V DC
J2 J1 AT FLOOR + -
SPA
MK 2 B 2 LEVEL PAL
13 14
ML 1 M 1 BUZZER 220V AC
AFL
UBL: Car bottom warning lamp and buzzer
SPA: Control panel lighting switch
PAL: Lamp for control panel
Jumper-1: J1- Selection of Mono-Stabil or Bi-Stabil switch
FD: At floor level lamp
Jumper-2 : J2- Selection of ML2 or MKD input
First Drawing Modification Board Series Customer Serial Number Confirm : CONTROL PANEL LAMP Page Number 14
Date Date 27.03.2019 Project No
Draw Draw Form No Model Referance Number of Pages 18
0 1 2 3 4 5 6 7 8 9
5.9 / D
5.9 / C
5.9 / B
5.9 / A
5.9 / C0
5.9 / C1
5.9 /C15
5.9 / 39
5.9 / 32
5.9 / 31
5.9 / 12
SDLP
- + A
24V DC max.1W DKB-n B
a C
YOLP
- +
NO C 2b f b D
2g g
24V DC max.1W E
TOP FLOOR -
AOLP
+ FCL-n 2c e
d
c F
+ - G
24V DC max.1W
2BC
MSLP 24V DC max.1W 2G
- +
DIGITAL DISPLAY
24V DC max.1W
COM
SDLP A
- +
DKB-2
B
24V DC max.1W
a C
YOLP
INTERMEDIATE - +
NO C
2g
2b f
g
b D
24V DC max.1W
E
FLOORS AOLP
- + +
FCL-2
-
2c e
d
c F
G
24V DC max.1W
24V DC max.1W 2BC
MSLP 2G
- + DIGITAL DISPLAY
COM
24V DC max.1W
SDLP
- + A
DKB-1
24V DC max.1W B
a C
YOLP NO C
- + b D
2b f
2g g
E
BOTTOM FLOOR 24V DC max.1W
AOLP FCL-1
2c e c F
- + + - d
G
24V DC max.1W
24V DC max.1W 2BC
MSLP 2G
- + DIGITAL DISPLAY
COM
24V DC max.1W
First Drawing Modification Board Series Customer Serial Number Confirm : FLOOR CONNECTIONS Page Number 15
Date Date 27.03.2019 Project No
Draw Draw Form No Model Referance Number of Pages 18
0 1 2 3 4 5 6 7 8 9
Socket
220V AC
PID : Pit Inspection Control Station
KRR : Pit inspection reset switch Alarm Button
Pit Lightning KD-KAB
Button
SB09 : Pit Inspection Station Operation Switch
SB10 : Pit Inspection Station Run Button 4 3 4 3
SB11 : Pit Inspection Station Up Button
SB12 : Pit Inspection Station Down Button
HGK :Overspeed Governor Tension Rope Control Contact
KDMK : Pit Ladder Safety Contact KD-STP
SSDN : Lower Limit
Pit STOP
BF1 : Pit Buffer Contact
BF2 : Pit Conterweight Buffer Contact 2 1
12V+
Mp/N
110A
110B
SLP1
SLP2
ALM
1/L
PE
PE
XP-ST1
HGK
KDMK
INTEGRATED 110C
2 1
SSDN
110D
DEVICE 110D
2 1 BF1
111
XP-SF3
2 1
113A BF2
114 2 1
12V+ 114
ALM 114A
XK-KRS
2 1
1/L 114A
119 Mp/N 115
118A SLP1
118 SLP2
117A PE
117
Pit Inspection STOP
116
115
114
18 Wires
SPB 1 2 1
PID
113A
SB09
111
110A
PIT CONTROLLER 2
SLP2
SLP1 110A BOARD 3 3.1 3.2
Mp/N 111
113A 4 2.1 2.2
1/L
ALM 114 SB10
XP-SF1
XP-SF2
118A
119 117 4 8
117A 5 SB11 1.3 1.4
118 6
118A 7
119 8 2.3 2.4
9 1.3 1.4
511-Y7 4 Wires 9
XK-IN2
510-Y6 10 SB12
871-Y5 10
11
1000 Y-G
2.3 2.4
1.3 1.4
11
Yellow-Green
4 Wires KD-KRR
XK-CB
CH 100
CL 1000 KRR
1000 CL
100 1000
CH
XK-IN1
KRR-Y4
Y3 4 3
Y2
Y1
KDM Y1 Y2 Y3
Free Input
PIT CONTROLLER
BOX
First Drawing Modification Board Series Customer Serial Number Confirm : KDM CONTROL BOX CONNECTIONS Page Number 16
Date Date 27.03.2019 Project No
Draw Draw Form No Model Referance Number of Pages 18
0 1 2 3 4 5 6 7 8 9
11.9 / FT2
11.9 / K2C
11.9 / KL2
15.9 / 100
15.9 / 1000
14.9 / MP
12.9 / 1
11.9 / SCL2
11.9 / C12V2
11.9 / K15-B
11.9 / K5-B
11.9 / K3-B
6.9 / DR2
4.9 / DR3
11.9 / FOT
11.9 / K1C
11.9 / KL1
11.9 / DTP
11.9 / SCL
11.9 / C12V
11.9 / K15-A
11.9 / K5-A
11.9 / K3-A
11.9 / PE
DR3 PE DR2 K3A 1000 K5A C12V SCL 1000 KL1 K1C 1 PE MP 1000 FOT DR3 PE DR2 K3B 1000 K5B C12V SCL2 DTP 1000 KL2 K2C 1 PE MP 1000 FT2
5 6 7 8 10 12 23 25 47 33 35 41 5 6 7 8 10 12 23 25 33 35 41
46 45 34 40 39 L PE N C NC NO 46 45 47 34 40 39 L PE N C NC NO
N GND F CLS COM OPN +12V SLOW N GND F CLS COM OPN +12V SLOW
COM CLOSE COM CLOSE
SUPPLY SUPPLY SUPPLY SUPPLY
INPUTS INPUTS
220V AC PRIORITY 220V AC 220V AC PRIORITY 220V AC
INPUTS INPUTS
First Drawing Modification Board Series Customer Serial Number Confirm : DOORS CONNECTION Page Number 17
Date Date 5.04.2019 Project No
Draw Draw Form No Model Referance Number of Pages 18
Date
Draw
MAP OF SHAFT LIMIT SWITCHES WHEN FLOOR SELECTOR IS MOTOR ENCODER COUNTER
0
First Drawing
Date
Draw
300mm TOP FLOOR M...
1
Modification
d2
d1
27.03.2019
1400 mm
d2
RAIL
ML1-2
Form No
Project No
Board Series
MKU-D
2
MAGNET
Model
Customer
d1 : The distance betwen two
3
Referance
Serial Number
818
817
1000
MKD
MKU
4
MKD
MKU
Confirm :
817
5
818
SAFE ZONE LIMIT
FLOOR 1
FOR RELEVELLING 100mm
ML2
ML1
MLC
MAGNET
6
ML1
ML2
Red Magnet
Black Magnet
7
30 cm strip magnet
1400 mm
150mm
BOTTOM
FLOOR 10 cm strip magnet
ML2 MKD
BI-STABLE
ML1 MKU
MAGNETIC SWITCH
Page Number
9