Maestro 81 20 Gearless Eng 1

Download as pdf or txt
Download as pdf or txt
You are on page 1of 18

0 1 2 3 4 5 6 7 8 9

LINE
3X380 V AC
L1 L2 L3 N PE

MACHINE ROOM INTERCOM


PHONE
1 3 1 3 DISTRIBUTION PANEL
FTKR-KL FTKR-SL
1 3 5 7
QF-1
30mA 30mA
IΔ IΔ
(25A) (25A)
2 4 2 4

2 4 6 8
F2-16A
B C

1 3 5 7 9
MSS-1 F3-10A
40A
2 4 6 8 10
A1
3
KSL-1
220V AC
4
A2
1 3 5 7
F1 SBL-1
25A
2 4 6 8
3 4
INT-C / 12.0
L1 L2 L3 N LP2 LP1 PE NF 1F
INT-B / 12.0
1F / 2.0
NF / 2.0
PE / 2.0
LP1 / 2.0
LP2 / 2.0
N / 2.0
L3 / 2.0
L2 / 2.0
L1 / 2.0
12V+ / 11.0
Supply terminals of rescue system ALM / 11.0
power device output (LP1-LP2) must be 1 / 2.0
passed from main switch contacts (NO). SL-n
MP / 2.0

220V AC

Power main switch


shall be min. AC-23B Type

QF-1 : Ground Fault Circuit Breaker


MSS-1 : Main Switch
F1 : Group Circuit Breaker for Main Power
F2 : Circuit Breaker for Shaft Lamps SL-2
SBL-2 S-ALM
F3 : Circuit Breaker for Control Panel Ligting and Car Lihgting L PE N
FTKR-KL : Ground Fault Circuit Breaker For Car Lighting SOCKET
3 4 3 4
FTKR-SL : Ground Fault Circuit Breaker For Shaft Lighting SL-1 Alarm
220V AC

SBL-1 : Shaft Lamps Button in Machine Room Button

SBL-2 : Shaft Lamps Button in Pit


SL-1..SL-n : Shaft Lighting Lamps PIT
KSL-1 : Teleruptor for Shaft Lamps

First Drawing Modification Board Series ELECTRIC Customer Serial Number Confirm : MACHINE ROOM CONNECTIONS Page Number 1
Date 29.03.2018 Date 27.03.2019 Project No AE-MAESTRO 01
Draw Hakan USTA Draw Hakan USTA Form No F/7.5.5.02.104 Model Referance Number of Pages 18
0 1 2 3 4 5 6 7 8 9

FKL-6A
1.9 / 1F 1 / 11.0
1F
1.9 / NF MP / 11.0
NF
1.9 / MP
1.9 / 1 FTR1-4A
1.9 / LP2 DR2 / 3.0
1.9 / LP1 DR3 / 3.0
-F4-25A

6 5
1.9 / L3
L3
4 3
1.9 / L2
L2
2 1
1.9 / L1
L1

1.9 / N
N

1.9 / PE PE / 4.0
PE

FTKR-30mA
25A
TRF-80W
1 3 220V 230V F110-1A


FUTKR
30mA 220V 2 1
25A
IΔ 110 / 3.0

2 4 0V 0V 4 3
150 / 4.0
SMPS-1
24V DC/min. 50W
L V+
I 100 / 4.0
AC
N V-
PE 1000 / 4.0

PE NUP LUP PE
BRAC / 6.0
UN UP L1 L2 L3 1 3

LINE KF
/7.4 2 4
P+ N
VARISTOR
Braking
PE NUP LUP LP NP
Resistor AE-MAESTRO L

AC AC
LINE LOAD DB MOTOR
PE RD1
BRAKE

UPSLIFT ENCODER U V W
KF
5 6
840P / 3.0
BAT- BAT+
/7.4
2000P / 3.0
BR2 / 4.0

BR1 / 4.0
T2 / 5.0
T1 / 5.0
BR2 BRC BR1 T2 T1
FBAT-25A
PE P2 P1
NC2 Com NC1
U V W

G Θ
PG PTC
U1 V1 W1
Motor
Thermistor
5x12V=60V - + M
3~
Brake Monitoring
Battery Group MOTOR 3x380V AC PE
Contacts
12V 7Ah

First Drawing Modification Board Series Customer Serial Number Confirm : POWER CONNECTIONS Page Number 2
Date Date 27.03.2019 Project No
Draw Draw Form No Model Referance Number of Pages 18
0 1 2 3 4 5 6 7 8 9

2.9 / DR2 DR2 / 4.0


2.9 / DR3 DR3 / 4.0
2.9 / 110 110 / 9.0
VARISTOR
2.9 / 840P BRK-AC
2.9 / 2000P
BRAKE-2
AC

AC

BRD

BS BB1

1.3 1.4 1.3 1.4

1.1 1.2 2.3 2.4

2.1 2.2

BB2
3.1 3.2

AC AC
OR 1.3 1.4
(RD7)
2.3 2.4

VARISTOR

OR Switch Position
1-0-2 3 3
0-Normal
1-Test
OR
Switch 4 4
2-Reset

OR- ORT+ ORR+


VBR1 VBR2

1n4007 1n4007 VARISTOR VARISTOR


D1 D2

/3.2 /3.1
BS : Mechanical brake test and rescue activation shalter.
2000 (B) BB1 : Mechanical brake test and rescue activation button 1.
2000 (A)

840 (B)
840 (A)

BB2 : Mechanical brake test and rescue activation button 2.

ORT- ORT+ ORR- ORR+


Coil voltage 190V DC Coil voltage 190V DC

OVERSPEED GOVERNOR OVERSPEED GOVERNOR Brake Brake

TEST COIL RESET COIL Coil-1


190V DC
Coil-2
190V DC

First Drawing Modification Board Series Customer Serial Number Confirm : UPS BRAKE Page Number 3
Date Date 11.04.2019 Project No
Draw Draw Form No Model Referance Number of Pages 18
0 1 2 3 4 5 6 7 8 9

CNT / 6.0
2.9 /PE PE / 11.0
3.9 / DR2 DR2 / 6.0
3.9 / DR3 DR3 / 17.0
2.9 / 100 100 / 5.0
2.9 / 1000 1000 / 5.0
2.9 / 150 120 / 8.0
125 / 8.0
130 / 8.0
135 / 9.0
140 / 8.0
151 / 6.0
ML1 / 13.0
ML2 / 13.0
SFR / 6.0
31 BRK / 7.0
KF
/7.4 32

100 1000 PE CNT CNN 150 120 125 130 135 140 151 ML1 ML2 S11 S14 S21 S24 S31 S34

P06- OUTPUT DEFINE P07-INPUT DEFINE


OUTPUT NO : S1 INPUT NO :I1 818 / 13.0
I8
OUTPUT CODE : 01/MOTOR CONTACTOR INPUT CODE :24/BR1 817 / 13.0
OUTPUT NO : S2 INPUT NO :I2 I7
OUTPUT CODE : 02/BRAKE CONTACTOR (KF) INPUT CODE :25/BR2 MKU / 13.0
OUTPUT NO : S3 INPUT NO :I3 I6
MKD / 13.0
OUTPUT
OUTPUT
CODE
NO
: 00/FREE
: S4 AE INPUT
INPUT
INPUT
CODE
NO
CODE
:00/FREE
:I4
:00/FREE
I5
OUTPUT CODE : 00/FREE
OUTPUT
OUTPUT
NO
CODE
: S5
: 00/FREE
MAESTRO INPUT
INPUT
NO
CODE
:I5
:14/MKD
OUTPUT NO : S6 INPUT NO :I6
INPUT CODE :15/MKU I4
OUTPUT CODE : 00/FREE
INPUT NO :I7 I3
INPUT CODE :4/817
INPUT NO :I8 I2
INPUT CODE :5/818
I1

S41 S44 S51 S54 S61 S64 GS GS1 VC VC1 B- B+ A+ A- CH1 CL1 CL0 CH0

CH0 / 5.0
CL0 / 5.0
CL1 /
CH1 /
VC1 / 6.0
VC / 6.0
GS1 / 6.0
GS / 6.0

2.9 / BR1
2.9 / BR2

First Drawing Modification Board Series Customer Serial Number Confirm : MAINBOARD CONNECTIONS Page Number 4
Date Date 27.03.2019 Project No
Draw Draw Form No Model Referance Number of Pages 18
0 1 2 3 4 5 6 7 8 9

4.9 / 100 100 / 6.0


4.9 / 1000 1000 / 6.0
4.9 / CL0 CL0 / 11.0
4.9 / CH0 CH0 / 11.0

CH CL 1000 100 BYP / 8.0


I20
550 / 9.0
I19
551 / 9.0
I18
870 / 9.0
I17

I16

I15
H01-INPUT DEFINE
I14
I17: 2/870
I18: 9/551 I13
I19: 8/550

ALPK I20: 10/BYP I12


2.9 / T1
T1 I11
2.9 / T2
T2 I10

I9

12 / 15.0
12
39 / 15.0
39
32 / 15.0
32
31 / 15.0
31

SC
*SC : Signal Common Input

C D E F G - 1x
C0 C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 A B
G4 G3 G2 G1 G0 2G 2BC

2BC / 15.0
2G / 15.0
G / 15.0
F / 15.0
E / 15.0
D / 15.0
C / 15.0
B / 15.0
A / 15.0
C15 / 15.0

C1 / 15.0
C0 / 15.0

First Drawing Modification Board Series Customer Serial Number Confirm : TERMINAL CONNECTIONS Page Number 5
Date Date 27.03.2019 Project No
Draw Draw Form No Model Referance Number of Pages 18
0 1 2 3 4 5 6 7 8 9

5.9 / 1000 1000 / 8.0


5.9 / 100 100 / 11.0
4.9 / 151 151 / 7.0
4.9 / VC1
4.9 / VC
4.9 / GS1
4.9 / GS
4.9 / SFR

2.9 / BRAC
4.9 / CNT
4.9 / DR2 DR2 / 17.0

SF11 SF12 R1-11 R1-14 R2-11 R2-14 R1-21 R1-24 R2-21 R2-24 SFR 151 100 1000 GS GS1 VC VC1

41 11 11 21 21 31 31
SFR1 SFR1 SFR2 SFR1 SFR2 A1 A1 SFR2 SFR1
/6.5 42 /6.5 14 /6.5 14 /6.5 24 /6.5 24 SFR1 SFR2 /6.5 34 /6.5 34
A2 A2
41
SFR2
11 14 /6.2 11 14 /6.3
/6.5 42
21 24 /6.3 21 24 /6.4
31 34 /6.7 31 34 /6.6
41 42 /6.1 41 42 /6.1

SER
BOARD

First Drawing Modification Board Series Customer Serial Number Confirm : SER BOARD CONNECTIONS Page Number 6
Date Date 27.03.2019 Project No
Draw Draw Form No Model Referance Number of Pages 18
0 1 2 3 4 5 6 7 8 9

4.9 / BRK

A1 C
KF
220V AC A2 R
CONTACTOR

6.9 / 151

1 2 /2.6
3 4 /2.6
6 5 /2.7
31 32 /4.3

First Drawing Modification Board Series Customer Serial Number Confirm : CONTACTOR CONNECTIONS Page Number 7
Date Date 27.03.2019 Project No
Draw Draw Form No Model Referance Number of Pages 18
0 1 2 3 4 5 6 7 8 9

6.9 / 1000 1000 / 9.0


116 / 9.0
116A / 9.0
4.9 / 120 120 / 9.0
4.9 / 125 125 / 9.0
4.9 / 130 130 / 9.0
4.9 / 140 140 / 9.0
5.9 / BYP

S-BPS
BYPASS

0-NORMAL
1 2 0

3 4 0

DS-1 5 6 1

DS-2 7 8 2

DS-3 9 10 3

! ! !
DS-1 DS-2 DS-3 S-BPS: Bypass switch.
/9.7 /9.8 /9.9
0 0: Bypass switch Normal Position.
S-BPS S-BPS S-BPS
BYPASS S-BPS 1 DS-1: Bypass Contact of Semi Automatic Landig Door Contacts or
BYPASS BYPASS Automatic Landing Door (Door-B) Lock Contacts.
BYPASS
0-NORMAL 2 DS-2: Bypass Contact of Semi Automatic Landig Door Locking Contacts or
1-DS1 3-DS3
1 2 2-DS2 Automatic Landing Door (Door-A) Lock Contacts.
0 1 2 1 2
0 1 2 0
0 3 DS-3: Bypass Contact of, Automatic Car Door Contacts (Door-A and Door-B).
3 4 3 4 3 4
0 0 3 4 0
0
5 6 5 6
5 6 1 5 6 1
1 1
7 8
7 8 7 8 7 8 2
2 2 2
9 10
9 10 9 10
3 3
3 9 10
3

First Drawing Modification Board Series Customer Serial Number Confirm : BYPASS CIRCUIT CONNECTIONS Page Number 8
Date Date 27.03.2019 Project No FUL AUTOMATIC DOOR (FOR ONE CAR DOOR)
Draw Draw Form No Model Referance Number of Pages 18
0 1 2 3 4 5 6 7 8 9

8.9 /1000 1000 / 11.0


8.9 / 140
4.9 / 135

8.9 / 130

8.9 / 125
8.9 / 120
5.9 /550 871 /
5.9 / 551 511 /
5.9 / 870 510 /
To KDM
SB03
Box
EED SB01 3 4
SS55
SB02 SB04
1.3 1.4

2 1 2.3 2.4 3 4 3 4

1.1 1.2

8.9 / 116A ! ! !
8.9 / 116
DS-1 DS-2 DS-3
/8.1 /8.2 /8.3

3.9 / 110

110 111 112 113 114 115 116 117 117A 118 118A 119 120 125 130 135 140

Door-B Door-A Door-A Door-B


SB09
SS40
1
PID SB10 12
LKK-nB LKK-nA
2
12
11 1.1 1.2 SS54
SS50 1.3 1.4 11
SS45
12 1.3 1.4 2.3 2.4
11 OKK-1 OKK-2
11

SS48 2.1 2.2


1
SS41 12 SB11
3.1 3.2
b 2
12
LKK-2B LKK-2A
1.3 1.4 2
SS56 11
2.3 2.4
SS53
11
SS49 1
1 12 12
SB12
SS42 SS46
2
11 11 1.3 1.4
SS47
2.3 2.4
12

12

SS44 LKK-1B LKK-1A


SB05
SS52
11
11 CID SB06
SS43 SS51 1.1 1.2

12 1.3 1.4 1 2

1.3 1.4 2.3 2.4


2 1
CID : Car Inspection Control Station
2.1 2.2
SS40 : Machine Side Stop PID : Pit Inspection Control Station
SS41 : Reel Room Stop SB01 : Emergency Electrical Operation Switch SB07 EED : Emergency Electrical Operation Control Device
SS42 : Pit Stop SB02 : Emergency Electrical Operation Run Button
3.1 3.2
SS43 : Pit Inspection Station Stop SB03 : Emergency Electrical Operation Up Button
SS44 : Overspeed Governor Rope Tensioning Weight Stop Contact SB04 : Emergency Electrical Operation Down Button 1.3 1.4
SS56 : Pit Ladder Stop Contact SB05 : Car Inspection Station Operation Switch /10.4 501 / 11.0
SS45 : Overspeed Governor Stop Contact SB06 : Car Inspection Station Run Button
2.3 2.4
SS46 : Loose Rope Stop Contact SB07 : Car Inspection Station Up Button
SS47 : Well Limit Stop Up SB08 : Car Inspection Station Down Button SB08
SS48 : Well Limit Stop Down SB09 : Pit Inspection Station Operation Switch
SS49 : Cabin Buffer Stop Contact SB10 : Pit Inspection Station Run Button
SS50 : Counter Weight Buffer Stop Contact SB11 : Pit Inspection Station Up Button 1.3 1.4
SS51 : Cabin Parachute Stop Contact SB12 : Pit Inspection Station Down Button 500 / 11.0
SS52 : Car Inspection Station Stop LKK-xx : Automatic Landing Door Lock Contacts
SS53 : Car Top Stop LFK-xx : Semi Automatic Landing Door Contacts 2.3 2.4
SS54 : Cabin Roof Exit Door Stop Contact OKK-xx : Car Door Contacts
SS55 : Emergency Electrical Operation Device Stop LDK-xx : Semi Automatic Landing Door Locking Contacts 869 / 11.0

First Drawing Modification Board Series Customer Serial Number Confirm : SAFETY LINE CONNECTIONS Page Number 9
Date Date 27.03.2019 Project No FULL AUTOMATIC DOOR
Draw Draw Form No Model Referance Number of Pages 18
0 1 2 3 4 5 6 7 8 9

SS40 SS42 SS43 SS55


SS44 SS56 SS58 SB01 SB02

110 1 2 1 2 1 2 11 12 11 12 11 12 1 2 1.3 1.4 3 4


111 112 117
Pit Enterance Emergency S-BPS
Emergency Electrical
Machine Pit Stop Pit Inspection Overspeed Pit Ladder Door BYPASS
Emergency Electrical Operation
Side Stop Station Stop Governor Stop Contact Contact SB01
Electrical Operation Run Button
Rope Tensioning Switch
Weight Stop Operation 0
Contact Device Stop
1.2 1.1 4 3
110A 110B 110C 110D 110E 110F
116A
Emergency
Electrical
Operation Switch

SS45 SS46 SS47 SS48 SS49 SS50 SS51


BYPASS
S-BPS
!!! Bridge Unused Safety Circuit Terminals. 11 12 11 12 11 12 11 12 11 12 11 12 11 12

0-NORMAL 113 114 115 116


Loose Rope Well Limit Well Limit Cabin Buffer Counter Cabin
BYP 0 1000 Overspeed
1 2 Stop Contact Stop Up Stop Down Stop Contact Weight Parachute
Governor
Buffer Stop Stop Contact
Stop Contact
Contact
116 3 4 0 116A
SB05
Pit Inspection SB11 112A SB10 SB09 113A 114A

120 DS-1 1 125 Up Button


5 6
2.4 2.3 1.4 1.3 1.4 1.3 2.2 2.1

125 DS-2 2 130 118A


7 8 Pit Inspection Pit Inspection
Station Station SB06 Car Inspection
Pit Inspection SB12 Station
Run Button Operation
3 Down Button Operation Switch
130 DS-3 9 10 140 Switch
1.4 1.3
2.4 2.3
S-BPS: Bypass switch. Car Inspection
0 0: Bypass switch Normal Position. Station
Run Button
SB09
1 DS-1: Bypass Contact of Semi Automatic Landig Door Contacts or Car Inspection SB07 SB06 SB05
Automatic Landing Door (Door-B) Lock Contacts. Station
2 DS-2: Bypass Contact of Semi Automatic Landig Door Locking Contacts or Up Button
2.4 2.3 1.4 1.3 1.4 1.3 2.2 2.1
Automatic Landing Door (Door-A) Lock Contacts.
3 DS-3: Bypass Contact of, Automatic Car Door Contacts (Door-A and Door-B). /9.6 118
Car Inspection Car Inspection SB10 Pit Inspection
SB08 Station Station Station
Car Inspection
Run Button Operation Switch Operation Switch
Station 1.4 1.3
Down Button 2.4 2.3
Pit Inspection
Station
SS53 SS52 Run Button
SS57 SS54 SB05 SB09

12 11 12 11 2 1 2 1 1.2 1.1 3.2 3.1


119 117A
Pit Inspection
MRL System Cabin Roof Car Top Stop Car Inspection Station
Car Inspection
Car Fixing Exit Door Station Operation Switch
Station Stop
Contact Stop Contact Operation Switch

Only For
Machine Roomless
Application
ICM
SFC SFB SFA RSB

SDB
141

Landing Door Lock Contacts Landing Door Lock Contacts


DOOR-B DOOR-A Car Door Contacts
LKK-1B LKK-2B LKK-nB LKK-1A LKK-2A LKK-nA OKK-1 OKK-2
DOOR-A DOOR-B
140

120 125 130 135

S-BPS S-BPS S-BPS


BYPASS BYPASS BYPASS
DS-1 DS-2 DS-3
1 2 3
5 6 7 8 9 10

First Drawing Modification Board Series Customer Serial Number Confirm : SAFETY LINE CONNECTIONS Page Number 10
Date Date 5.04.2019 Project No FULL AUTOMATIC DOOR
Draw Draw Form No Model Referance Number of Pages 18
0 1 2 3 4 5 6 7 8 9

2.9 / 1 1 / 12.0
2.9 / MP MP / 14.0
6.9 / 100 100 / 12.0
9.9 / 1000 1000 / 12.0
5.9 / CL0 CL0 / 12.0
5.9 / CH0 CH0 / 12.0
4.9 / PE PE / 17.0
UBL / 14.0
C12V / 17.0
SCL / 17.0
35 / 12.0
409 416 C12V2 / 17.0
Cabin SCL2 / 17.0
CALLS

PE
H01- INPUT DEFINE 10
N1: 1/869 CH CL GND V+ 409 410 411 412 413 414 415 416 CM5 R5 CM4 R4 CM3 R3 C4 CM1 K15-B / 17.0

OUTPUTS
N11: FREE R9
N2: 7/501 N12: 32/KL2 2G G F E D C B A DISP (O4)
N3: 6/500 H02- OUTPUT DEFINE R1 K3-B / 17.0
N13: 29/K22 G0 G1 G2 31 32 39 35 R1: 60/Second door close command
N4: 16/804 N14: 30/DT2 OUT
Set parameter B-30 for Car display outputs R2: 61/Second door open command Optional R2 K5-B / 17.0
1 N5: 22/KL1 N15: 34/FT2
B-30 Car display output R3: 28/Overload lamp
N6: 18/K20
2
N7: 19/DTS
N8: 20/FOT
N16: 33/K2C
0- 7 Segment
1- Gray code
SCB R4: 55/Slow close-1
R5: 62/Bypass warning
DOOR
KK/K3 K3-A / 17.0

N9: 23/K1C INPS 2- Binary code Serial Communication R9: 56/Slow close-2
SIGNALS KO/K15 K15-A / 17.0
N10: 28/DTP Optional 3- 7 Segment+Arrow Cabin Board KA/K5 K5-A / 17.0
I-BUTTON INPUTS (I1) (I2) (I3) (I4) CALLS
IB+ IB- N1 N2 N3 N4 N5 N6 N7 N8 N9 N10 N11 N12 N13 N14 N15 N16
401 402 403 404 405 406 407 408 - BAT + - EL + - SPK + - AB + - 12V +

1.9 / 12V+ 12V+ / 12.0


1.9 / ALM 12V- / 12.0

Cabin 408 / 12.0


CALLS
9.9 / 869 402 / 12.0
9.9 / 501 401 / 12.0
9.9 / 500 ALM / 12.0
K2C / 17.0
FT2 / 17.0
DT2 / 12.0
K22 / 12.0
KL2 / 17.0
DTP / 17.0
K1C / 17.0
FOT / 17.0
DTS / 12.0
K20 / 12.0
KL1 / 17.0
CFAN / 12.0
EL+ / 12.0
EL- / 12.0
MP 2 MP CFAN 1000 804

Cabin C-OVL CT-EL: Car top emergency lamp


Cabin Cabin FAN 1 C NO
CT-ALM: Car top alarm button
220V AC CT-ALP: Lamp for alarm button CT-ALM
LAMP-2 LAMP
M K20: Door open button CT-EL
max 500W max 500W Battery
K20-LP: Lamp door open button 12V DC Speaker
220V AC 220V AC 1~ 14 13
DTS: Door close button - + - + - +
CT-ALP
2
DTS-LP: Lamp for door close button 12V DC
PE
C-OVL: Cabin overload contact 12V DC - +
2.2Ah

First Drawing Modification Board Series Customer Serial Number Confirm : INSPECTION BOX CONNECTIONS Page Number 11
Date Date 27.03.2019 Project No
Draw Draw Form No Model Referance Number of Pages 18
0 1 2 3 4 5 6 7 8 9

1
11.9 / 1 / 17.0
11.9 /CFAN
11.9 / 100 100 / 13.0
11.9 / 1000 1000 / 13.0
11.9 /CL0
11.9 / CH0

1.9 / INT-B
1.9 / INT-C
11.9 / 12V-
11.9 / 12V+ 12V+ / 13.0
11.9 /35
11.9 / K22
11.9 / DT2
11.9 /K20
11.9 / DTS
11.9 / ALM

11.9 / EL+
11.9 / EL-

CH CL GND V+
400-n Cabin
Display
Indicator
11.9 / 408 IKB-n CDH
Cabin
CALLS NO C

11.9 / 402 CRL-n


- +
11.9 / 401
24V DC max.1W

IKB-8

NO C

CRL-8
- + B-INT
24V DC max.1W
C-ALM NO C
K20 K22

NO C NO C NO C
ILP
+ -
K20-LP K22-LP
IKB-2 DTS - + DT2 - +
12V DC
24V DC C-ALP 24V DC
NO C NO C + - NO C
OVLP
CRL-2 DTS-LP
C-EL 12V DC DT2-LP - +
- + - + - + - + BUT + - C B
+ - NO C
24V DC 12V Phone
24V DC max.1W 24V DC 12V DC 24V DC 24V
R-FAN
IKB-1 - +

C-EL: Cabin emergency lamp


INTERCOM
NO C
C-ALM: Cabin alarm button E2 FAN Button
CRL-1 C-ALP: Lamp for alarm button Buzzer Board
- + K20: Door open button
K20-LP: Lamp for door open button
24V DC max.1W
DTS: Door close button OVLP: Overload lamp
DTS-LP: Lamp for door close button B-INT: Intercom button
IKB: Cabin call button K22: Second door open button ILP: Lamp for intercom button
CRL: Cabin call register lamp K22-LP: Lamp for second door open button
DT2: Second door close button
DT2-LP: Lamp for second door close button

First Drawing Modification Board Series Customer Serial Number Confirm : C.O.P. CONNECTIONS Page Number 12
Date Date 5.04.2019 Project No
Draw Draw Form No Model Referance Number of Pages 18
0 1 2 3 4 5 6 7 8 9

12.9 / 100 100 / 14.0


12.9 / 1000 1000 / 14.0

12.9 / 12V+ 12V+ / 14.0


4.9 / ML2 ML2 / 14.0

4.9 / ML1 ML1 / 14.0


4.9 / MKU

4.9 / MKD

4.9 / 818
4.9 / 817

D1 D2
1N4007 1N4007

ML1 MLC ML2

817 1000 818 1000 MKD 1000 MKU 1000

817/ 818/ MKD MKU ML1 ML2


KSR1 KSR2

Roller Switch Or Roller Switch Or Mono-Stable Mono-Stable Mono-Stable Mono-Stable


Bi-Stable Magnetic Switch Bi-Stable Magnetic Switch Magnetic Switch Magnetic Switch Magnetic Switch Magnetic Switch

First Drawing Modification Board Series Customer Serial Number Confirm : MAGNETIC SWITCH CONNECTIONS Page Number 13
Date Date 27.03.2019 Project No
Draw Draw Form No Model Referance Number of Pages 18
0 1 2 3 4 5 6 7 8 9

14.9 / 1 1 / 14.0
11.9 / MP MP / 17.0
13.9 / 100 100 / 15.0
13.9 / 1000 1000 / 15.0
11.9 / UBL
13.9 / 12V+

13.9 / ML1
13.9 / ML2

FD+ FD-

UBL
MKD/ML2 ML1 FD- FD+ +12V 1000 100 FD
+ -

12V DC 24V DC
J2 J1 AT FLOOR + -
SPA

MK 2 B 2 LEVEL PAL
13 14

ML 1 M 1 BUZZER 220V AC

AFL
UBL: Car bottom warning lamp and buzzer
SPA: Control panel lighting switch
PAL: Lamp for control panel
Jumper-1: J1- Selection of Mono-Stabil or Bi-Stabil switch
FD: At floor level lamp
Jumper-2 : J2- Selection of ML2 or MKD input

First Drawing Modification Board Series Customer Serial Number Confirm : CONTROL PANEL LAMP Page Number 14
Date Date 27.03.2019 Project No
Draw Draw Form No Model Referance Number of Pages 18
0 1 2 3 4 5 6 7 8 9

14.9 / 100 100 / 17.0


14.9 / 1000 1000 / 17.0
5.9 / 2G
5.9 / 2BC
5.9 / G
5.9 / F
5.9 / E

5.9 / D
5.9 / C
5.9 / B
5.9 / A

5.9 / C0
5.9 / C1

5.9 /C15
5.9 / 39
5.9 / 32

5.9 / 31
5.9 / 12

SDLP
- + A
24V DC max.1W DKB-n B
a C
YOLP
- +
NO C 2b f b D
2g g
24V DC max.1W E
TOP FLOOR -
AOLP
+ FCL-n 2c e
d
c F
+ - G
24V DC max.1W
2BC
MSLP 24V DC max.1W 2G
- +
DIGITAL DISPLAY
24V DC max.1W
COM

SDLP A
- +
DKB-2
B
24V DC max.1W
a C
YOLP
INTERMEDIATE - +
NO C
2g
2b f
g
b D
24V DC max.1W
E
FLOORS AOLP
- + +
FCL-2
-
2c e
d
c F
G
24V DC max.1W
24V DC max.1W 2BC
MSLP 2G
- + DIGITAL DISPLAY
COM
24V DC max.1W

SDLP
- + A
DKB-1
24V DC max.1W B
a C
YOLP NO C
- + b D
2b f
2g g
E
BOTTOM FLOOR 24V DC max.1W
AOLP FCL-1
2c e c F
- + + - d
G
24V DC max.1W
24V DC max.1W 2BC
MSLP 2G
- + DIGITAL DISPLAY
COM
24V DC max.1W

SDLP: Out of service lamp DKB-xx: Landing call button


YOLP: Up arrow lamp FCL-xx: Landing call register lamp
AOLP: Down arrow lamp KRR: Pit inspection reset switch
MSLP: Busy lamp

First Drawing Modification Board Series Customer Serial Number Confirm : FLOOR CONNECTIONS Page Number 15
Date Date 27.03.2019 Project No
Draw Draw Form No Model Referance Number of Pages 18
0 1 2 3 4 5 6 7 8 9

Socket
220V AC
PID : Pit Inspection Control Station
KRR : Pit inspection reset switch Alarm Button
Pit Lightning KD-KAB
Button
SB09 : Pit Inspection Station Operation Switch
SB10 : Pit Inspection Station Run Button 4 3 4 3
SB11 : Pit Inspection Station Up Button
SB12 : Pit Inspection Station Down Button
HGK :Overspeed Governor Tension Rope Control Contact
KDMK : Pit Ladder Safety Contact KD-STP
SSDN : Lower Limit
Pit STOP
BF1 : Pit Buffer Contact
BF2 : Pit Conterweight Buffer Contact 2 1

12V+

Mp/N

110A
110B
SLP1
SLP2
ALM
1/L

PE
PE
XP-ST1
HGK
KDMK
INTEGRATED 110C
2 1
SSDN
110D
DEVICE 110D
2 1 BF1
111

XP-SF3
2 1
113A BF2
114 2 1
12V+ 114
ALM 114A

XK-KRS
2 1
1/L 114A
119 Mp/N 115
118A SLP1
118 SLP2
117A PE
117
Pit Inspection STOP
116
115
114
18 Wires
SPB 1 2 1
PID
113A
SB09
111
110A
PIT CONTROLLER 2

SLP2
SLP1 110A BOARD 3 3.1 3.2

Mp/N 111
113A 4 2.1 2.2
1/L
ALM 114 SB10
XP-SF1

12V+ 115 5 1.3 1.4


116
117
117A 110B 1 6 2.3 2.4 1.1 1.2
118 110C 2
8 Wires 7
116 3

XP-SF2
118A
119 117 4 8
117A 5 SB11 1.3 1.4
118 6
118A 7
119 8 2.3 2.4
9 1.3 1.4
511-Y7 4 Wires 9
XK-IN2

510-Y6 10 SB12
871-Y5 10
11
1000 Y-G
2.3 2.4

1.3 1.4
11

Yellow-Green

4 Wires KD-KRR
XK-CB

CH 100
CL 1000 KRR
1000 CL
100 1000
CH
XK-IN1

KRR-Y4
Y3 4 3
Y2
Y1

KDM Y1 Y2 Y3
Free Input
PIT CONTROLLER
BOX

First Drawing Modification Board Series Customer Serial Number Confirm : KDM CONTROL BOX CONNECTIONS Page Number 16
Date Date 27.03.2019 Project No
Draw Draw Form No Model Referance Number of Pages 18
0 1 2 3 4 5 6 7 8 9

11.9 / FT2
11.9 / K2C
11.9 / KL2
15.9 / 100
15.9 / 1000
14.9 / MP
12.9 / 1
11.9 / SCL2
11.9 / C12V2
11.9 / K15-B
11.9 / K5-B
11.9 / K3-B
6.9 / DR2
4.9 / DR3

11.9 / FOT
11.9 / K1C
11.9 / KL1
11.9 / DTP
11.9 / SCL
11.9 / C12V
11.9 / K15-A

11.9 / K5-A
11.9 / K3-A

11.9 / PE

DR3 PE DR2 K3A 1000 K5A C12V SCL 1000 KL1 K1C 1 PE MP 1000 FOT DR3 PE DR2 K3B 1000 K5B C12V SCL2 DTP 1000 KL2 K2C 1 PE MP 1000 FT2

5 6 7 8 10 12 23 25 47 33 35 41 5 6 7 8 10 12 23 25 33 35 41
46 45 34 40 39 L PE N C NC NO 46 45 47 34 40 39 L PE N C NC NO
N GND F CLS COM OPN +12V SLOW N GND F CLS COM OPN +12V SLOW
COM CLOSE COM CLOSE
SUPPLY SUPPLY SUPPLY SUPPLY
INPUTS INPUTS
220V AC PRIORITY 220V AC 220V AC PRIORITY 220V AC
INPUTS INPUTS

TEMPERATURE CLOSED OBSTRUCTION TEMPERATURE CLOSED OBSTRUCTION


PHOTOCELL PHOTOCELL
SUPPLY SUPPLY
UNIT-1 UNIT-2
(DOOR BOARD-1) (DOOR BOARD-2)

DOOR 1 (A) DOOR 2 (B)

First Drawing Modification Board Series Customer Serial Number Confirm : DOORS CONNECTION Page Number 17
Date Date 5.04.2019 Project No
Draw Draw Form No Model Referance Number of Pages 18
Date
Draw
MAP OF SHAFT LIMIT SWITCHES WHEN FLOOR SELECTOR IS MOTOR ENCODER COUNTER
0

First Drawing
Date
Draw
300mm TOP FLOOR M...
1

Modification
d2
d1

27.03.2019
1400 mm
d2
RAIL

ML1-2

Form No
Project No
Board Series
MKU-D
2

MAGNET

Model
Customer
d1 : The distance betwen two
3

SAFE ZONE LIMIT


FLOOR 2 magnets in case there is
FOR RELEVELLING
not rail between them.
d2 : The distance between
magnetic shalter and
magnet.

Referance
Serial Number
818
817

1000
MKD
MKU
4

MKD
MKU

Confirm :
817
5

818
SAFE ZONE LIMIT
FLOOR 1
FOR RELEVELLING 100mm
ML2
ML1
MLC

MAGNET
6

ML1
ML2

Red Magnet
Black Magnet
7

30 cm strip magnet
1400 mm

150mm
BOTTOM
FLOOR 10 cm strip magnet

MKU-MKD KSR2 KSR1


8

ML1-ML2 STOPPER AND (818) (817)


SAFE ZONE LIMIT RE-LEVELLING
SENSOR FOR OPEN
DOOR LEVELLING 818
817

ML2 MKD
BI-STABLE
ML1 MKU
MAGNETIC SWITCH
Page Number
9

MONO STABLE MONO STABLE


Number of Pages

MAGNETIC SWITCH MAGNETIC SWITCH


18
18

You might also like