POWER SUPPLY SYSTEMS DEHNguard® modular

SPDS TYPE 2 DG M TT 275

Dimension drawing DG M TT ... FM Basic circuit diagram DG M TT ... FM Complete prewired unit for use in TT systems,
consisting of a base part and plug-in protection
DG M TT ... (FM): Modular surge arrester for use in TT and TN-S systems ("3+1" circuit) modules

Energy-coordinated within the Red/Line product


family

High discharge capacity due to powerful zinc


oxide varistors/spark gaps

High reliability due to "Thermo Dynamic


Control" SPD monitoring device

Operating state/fault indication of every


protective circuit

Multifunctional terminals for connecting


conductors and busbars

Allows for easy replacing of protection modules


without tools by module locking system with
releasing button

Tested for vibration- and shock-proofness acc.


to EN 60068-2

DG M TT 275
SPD according to EN 61643-11 Type 2
SPD according to IEC 61643-1 Class II
Nominal a.c. voltage [UN] 230/400 V
Max. continuous operating a.c. voltage [L-N] [UC] 275 V
Max. continuous operating a.c. voltage [N-PE] [UC] 255 V
Nominal discharge current (8/20 µs) [In] 20 kA
Max. discharge current (8/20 µs) [Imax] 40 kA
Lightning impulse current (10/350 µs) [N-PE] [Iimp] 12 kA
Voltage protection level [L-N] [UP] ≤ 1.25 kV
Voltage protection level [L-N] for 5 kA [UP] ≤ 1 kV
Voltage protection level [N-PE] [UP] ≤ 1.5 kV
Follow current extinguishing capability [N-PE] [Ifi] 100 Arms
Response time [L-N] [tA] ≤ 25 ns
Response time [N-PE] [tA] ≤ 100 ns
Max. mains-side overcurrent protection 125 A gL/gG
Short circuit withstand capability for max. mains-side overcurrent 50 kArms
protection
Temporary overvoltage (TOV) [L-N] [UT] 335 V / 5 sec.
Temporary overvoltage (TOV) [N-PE] [UT] 1200 V / 200 ms
Operating temperature range [TU] -40°C...+80°C
Operating state/fault indication green / red
Cross-sectional area (min.) 1.5 mm2 solid/flexible
Cross-sectional area (max.) 35 mm2 stranded/25 mm2 flexible

page1©2008 DEHN + SÖHNE GmbH + Co. KG Hans-Dehn-Str. 1 Postfach 1640 D-92306 Neumarkt, Germany, Tel. +499181 906-0 www.dehn.de, as at: 2008-04-07
For mounting on 35 mm DIN rail acc. to EN 60715
Enclosure material red thermoplastic, UL 94 V-0
Degree of protection IP 20
Dimension 4 mods., DIN 4
Approvals, Certifications KEMA, VDE, UL, VdS

Ordering information
Type DG M TT 275
Part No. 952 310
Packing unit 1pcs.
We reserve the right to modify design, technology, dimensions, weights and materials according to technical progress. Illustrations are non-binding. Pictures may differ from the modules described.

page2©2008 DEHN + SÖHNE GmbH + Co. KG Hans-Dehn-Str. 1 Postfach 1640 D-92306 Neumarkt, Germany, Tel. +499181 906-0 www.dehn.de, as at: 2008-04-07