0% found this document useful (0 votes)
81 views2 pages

Conemeter Datasheet

This document provides specifications for a cone meter used to measure flow. It includes: 1) A typical data sheet listing 57 parameters to describe the cone meter's components, measurements, accuracy, service conditions, and testing. 2) Details on the cone, body, flanges, taps, accuracy, manifold, flow computer, service conditions, and testing of the cone meter. 3) The format, procedure, issue and revision details for the specification.

Uploaded by

Shakeel Ahmed
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
81 views2 pages

Conemeter Datasheet

This document provides specifications for a cone meter used to measure flow. It includes: 1) A typical data sheet listing 57 parameters to describe the cone meter's components, measurements, accuracy, service conditions, and testing. 2) Details on the cone, body, flanges, taps, accuracy, manifold, flow computer, service conditions, and testing of the cone meter. 3) The format, procedure, issue and revision details for the specification.

Uploaded by

Shakeel Ahmed
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Spec. No.

3214
Offshore Design Section FUNCTIONAL SPECIFICATION
FOR
Rev. No. 01
Engineering Services
“CONE METER” Discipline Instt
ISO – 9001:2008
Page: 6 OF 7

ANNEXURE – I - Typical Data Sheet for Cone Meter

1 Tag Number
2 Line Number
GENERAL 3 Line Size & Schedule
4 Service
5 P&ID No
6 Inlet Line ID Outlet Line ID
7 Diff Range In mm H2O
METER
8 Meter Maximum
9 Type
10 Size
11 Cone Material
12 Beta Ratio
CONE 13 Bore Dia. ‘d’
14 Cone Gussets (y/n, No.)
15 Direction Horizontal only
Upstream Downstream
16
Length Length
17 Type
18 Flange Size Rating
19 Flange Material
BODY/FLANGES 20 Flange Facing & Finish
21 Body Material
22 Pipe Material Schedule
23 Pipe Type – Seamless / ERW
24 Material
TAPS 25 Tap Type Size
26 Number of tap sets per flange
27 Accuracy
28 Repeatability
ACCURACY 29 Turn Down Ratio
Calibration- Traceable to ISO 17025
30
Lab
MANIFOLD FOR 5 valve Min
31 Material Yes
TRANSMITTER Manifold SS316
32 Power Supply Cable Entry
33 Mounting Panel/Field Mounted
4-20 mA ,
Pulse inputs,
Digital inputs
34 Input Type Number RTD inputs,
0 – 5V .
Multi variable
sensor input
4-20 mA ,
FLOW COMPUTER Digital output ,
35 Output Type Number RS 232/485
/ Relay output

36 LCD display
37 In Built Permanent Type battery Min 2 years
38 Data archiving capacity
39 Standard used for Calculation
40 Enclosure class
41 Power consumption
42 Accuracy Repeatability

FORMAT No. Ref. PROCEDURE No. ISSUE No. REV. No. REV. DATE:
ODS/SOF/004 ODS/SOP/023 01 00 21.07.2010
Spec. No. 3214
Offshore Design Section FUNCTIONAL SPECIFICATION
FOR
Rev. No. 01
Engineering Services
“CONE METER” Discipline Instt
ISO – 9001:2008
Page: 7 OF 7

43 Fluid State
44 Flow Min. Maximum
45 Flow Normal
Inlet Pressure
46 Maximum
Operating
Temperature
47 Maximum
SERVICE CONDITIONS Operating
48 Sp. Gr. At Oper. Temp. 15 OC
49 Molecular Weight Cp / Cv
50 Operating Viscosity (Cp)
51 Compressibility Factor
52 Pipe Reynolds Number
53 IBR Certification
54 Manufacturer
ITEM DETAILS
55 Model Number
Other 56 Integral RTD (Y/N) / Size / Rating
57 Hydro Testing / Non Destructive Tests
58
59

FORMAT No. Ref. PROCEDURE No. ISSUE No. REV. No. REV. DATE: