EC RP ED 60Hz

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

R

EC Series
Generator Set Rating Book
EC Series Powered by Cummins Engines Three-phase 60Hz ,1800RPM
Standby Power Prime Power Control System ATS
Model Engine Alternator
kW
kVA kVAkW kW kVA
kVA kW
Auto Gen AMF Paralleling 208V* 480V*
GMS26C6/S 25 32 23 29 4B3.9-G1 PI144E √ √ ○ STD ○ × P100A ×
GMS31C6/S 31 39 28 35 4B3.9-G1 PI144G √ √ ○ STD ○ × P125A ×
GMS45C6/S 44 55 40 50 4BT3.9-G1 PI144K √ √ ○ STD ○ × P160A ×
GMS66C6/S 64 80 58 73 4BTA3.9-G2 UCI224E √ √ ○ STD ○ × P250A ×
GMS95C6/S 97 121 88 110 6BT5.9-G2 UCI274C √ √ ○ STD ○ × P400A ×
GMS125C6/S 123 154 112 140 6BTAA5.9-G2 UCI274D √ √ ○ ○ STD × P630A ×
GMS165C6/S 165 206 150 188 6CTA8.3-G2 UCI274F √ √ ○ ○ STD × P630A ×
GMS200C6/S 198 248 180 225 6CTAA8.3-G2 UCI274G √ √ ○ ○ STD ○ P800A ×
GMS240C6/S 242 303 220 275 6LTAA8.9-G2 UCDI274J √ √ ○ ○ STD ○ P1000A P400A
GMS220C6/S 220 275 N/A N/A NT855-GA UCDI274J √ √ ○ ○ STD ○ P800A P630A
GMS300C6/S 308 385 280 350 NTA855-G1B HCI444D √ √ ○ ○ STD ○ P1250A P630A
GMS350C6/S 352 440 320 400 NTA855-G3 HCI444ES √ √ ○ ○ STD ○ P1250A P400A
GMS400C6/S 386 483 351 439 KTA19-G2 HCI444E √ √ ○ ○ STD ○ P1600A P630A
GMS450C6/S 451 564 410 512 KTA19-G3 HCI444F √ √ ○ ○ STD ○ P1600A P800A
GMS500C6/S 495 619 450 563 KTA19-G4 HCI544C √ √ ○ ○ STD ○ P2000A P800A
GMS680C6/S 682 853 620 775 KT38-G HCI544F √ √ × ○ STD ○ × P1250A
GMS800C6/S 798 997 725 906 KTA38-G2 LVI634C √ √ × ○ STD ○ × P1250A
GMS880C6/S 880 1100 800 1000 KTA38-G2A LVI634D √ √ × ○ STD ○ × P1600A
GMS1020C6/S 1020 1275 927 1159 KTA38-G4 LVI634E √ √ × ○ STD ○ × P1600A
GMS1100C6/S 1100 1375 N/A N/A KTA38-G9 LVI634G √ √ × ○ STD ○ × P2000A
GMS1100C6/S 1100 1375 1000 1250 KTA50-G3 LVI634F √ √ × ○ STD ○ × P2000A
GMS1375C6/S 1375 1719 1250 1563 KTA50-G9 PI734B √ √ × ○ STD ○ × P2500A

Single-phase 60Hz, 1800RPM


Standby Power Prime Power Control System ATS
Model Engine Alternator
kW
kVA kVAkW kW kVA
kVA kW
Auto Gen AMF Paralleling 220V*
PC26S6/S 25 32 23 29 4B3.9-G1 PI144K √ √ ○ STD ○ × P160A
PC30S6/S 31 39 28 35 4B3.9-G1 UCI224D √ √ ○ STD ○ × P250A
PC45S6/S 44 55 40 50 4BT3.9-G1 UCI224F √ √ ○ STD ○ × P250A
PC66S6/S 64 80 58 73 4BTA3.9-G2 UCI274D √ √ ○ STD ○ × P400A
PC105S6/S 97 121 88 110 6BT5.9-G2 UCI274G √ √ ○ STD ○ × P630A

STD: Standard √: Available ○: Optional ×: Impossible


Notes:
- All ratings are for guidance only, please refer to the specific genset technical data sheet for final power ratings.
- 208V/480V: Selection of ATS models is calculated on the basis of 208V or 480V, for other voltages, please consult PowerLink before ordering.
- All ratings data based on operation under ISO 8528-1, ISO 3046, DIN6271 conditions using typical fan sizes and drive ratios. Performance tolerance quoted by PowerLink is ±5%.
- Prime Power = Power at available load in lieu of main power network. An overload of 10% permitted for one hour in every twelve hours of operation.
- Standby Power = Power available at a variable load in the event of a main power network failure up to a maximum of 500 hours per year. No over load is permitted.
- Rated power factor: 0.80.
- N/A: Not Available.

PowerLink reserves the right to make changes in model, technical sepcification, color, configuration and accessories without prior notice. Please contact your sales team before ordering.

www.powerlinkworld.com | [email protected]
RP Series
Generator Set Rating Book
RP Series Powered by Powerlink Engines Three-phase 60Hz, 1800RPM
Standby Power Prime Power Control System ATS
Model Engine Alternator
kW
kVA kVAkW kW kVA
kVA kW Auto Gen AMF Paralleling 208V* 220V*
GMS10PX6/S 9 12 8.6 11 3D1.4CG PI044E √ √ ○ STD ○ × P40A ×
GMS12PX6/S 12 14 10.5 13 3D1.5CG PI044F √ √ ○ STD ○ × P40A ×
GMS17PX6/S 17 21 15 19 4D2.3CG PI044H √ √ ○ STD ○ × P63A ×
GMS22PX6/S 22 28 20 25 4D2.7CG PI144D √ √ ○ STD ○ × P80A ×
GMS33PX6/S 31 39 28 35 4D3.2CG PI144G √ √ ○ STD ○ × P125A ×
GMS44PX6/S 44 55 40 50 4D5.0CG PI144J √ √ ○ STD ○ × P160A ×
GMS60PX6/S 59 74 54 68 4DT4.6CG UCI224E √ √ ○ STD ○ × P250A ×

Single-phase 60Hz, 1800RPM


PX10S6/S 9 12 9 11 3D1.4CG PI044H √ √ ○ STD ○ × × P63A
PX12S6/S 12 14 11 13 3D1.5CG PI144D √ √ ○ STD ○ × × P80A
PX16S6/S 15 19 14 18 4D2.3CG PI144G √ √ ○ STD ○ × × P100A
PX22S6/S 22 28 20 25 4D2.7CG PI144H √ √ ○ STD ○ × × P125A
PX30S6/S 31 39 28 35 4D3.2CG LSA42.3M8 √ √ ○ STD ○ × × P250A
PX44S6/S 44 55 40 50 4D5.0CG UCI224F √ √ ○ STD ○ × × P250A
PX60S6/S 59 74 54 68 4DT4.6CG UCI224G √ √ ○ STD ○ × × P400A

STD: Standard √: Available ○: Optional ×: Impossible


Notes:
- All ratings are for guidance only, please refer to the specific genset technical data sheet for final power ratings.
- 208V/480V: Selection of ATS models is calculated on the basis of 208V or 480V, for other voltages, please consult PowerLink before ordering.
- All ratings data based on operation under ISO 8528-1, ISO 3046, DIN6271 conditions using typical fan sizes and drive ratios. Performance tolerance quoted by PowerLink is ±5%.
- Prime Power = Power at available load in lieu of main power network. An overload of 10% permitted for one hour in every twelve hours of operation.
- Standby Power = Power available at a variable load in the event of a main power network failure up to a maximum of 500 hours per year. No over load is permitted.
- Rated power factor : 0.80.

PowerLink reserves the right to make changes in model, technical sepcification, color, configuration and accessories without prior notice. Please contact your sales team before ordering.

www.powerlinkworld.com | [email protected]