The document is a bill of quantities for the construction of a district court building in Indore, Madhya Pradesh. It provides estimates for civil and electrical works totaling Rs. 317.77 crore. It lists 13 items with descriptions of work like excavation, filling, preconstruction antitermite treatment, and provides quantities, rates and amounts for each. The largest estimated costs are for excavation of all kinds of soil, filling with crusher stone dust/coarse sand, and preconstruction antitermite treatment.

Uploaded by

Pradeep Parvate
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
146 views66 pages

Schedulec

The document is a bill of quantities for the construction of a district court building in Indore, Madhya Pradesh. It provides estimates for civil and electrical works totaling Rs. 317.77 crore. It lists 13 items with descriptions of work like excavation, filling, preconstruction antitermite treatment, and provides quantities, rates and amounts for each. The largest estimated costs are for excavation of all kinds of soil, filling with crusher stone dust/coarse sand, and preconstruction antitermite treatment.

Uploaded by

Pradeep Parvate
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 66

BILL OF QUANTITIES FOR CONSTRUCTION OF DISTRICT COURT BUILDING AT

INDORE(M.P.)
Amount(in
T/S 1 APD PWD PIU Indore T/S. No. 245/2018 Dt. 09-08-18 (Civil Work) 275.05
crore)
T/S 2 JPD E&M Office of the Project Director PWD PIU Bhopal, SER No. 08/18-19 Dt 10-08- Amount (in
42.72
18 (Electrical Work) crore)

P.A.C. 317.77

S.No S.O.R No.


Description Unit Qty Rate Amount

SOR Work
1 1.1 Transportation By Mechanical Transport
including loading ,unloading and stacking.

5 Km.
1.1.2 Earth Cum 12301.3 186.34 22,92,175
1.1.4 Excavated rock Cum 6258.3 298.14 18,65,868
2 2.1 Surface dressing of the ground including
removing vegetation and in-equalities not
exceeding 15 cm deep and disposal of
rubbish, lead upto 50 m and lift upto 1.5
m.
2.1.1 All kinds of soil. 100
251.8 722.70 1,81,974
sqm
3 2.2 Clearing jungle including uprooting of rank
vegetation, grass, brush wood, trees and
saplings of girth upto 30 cm measured at a
100
height of 1 m above ground level and 200.9 372.60 74,849
sqm
removal of rubbish upto a distance of 50 m
outside the periphery of the area cleared.

4 2.6 Earth work in excavation by mechanical


means (Hydraulic excavator )/ manual
means over areas (exceeding 30cm in
depth. 1.5m in width as well as 10 sqm on
plan) including dressing of sides and
ramming of bottom disposal of excavated
earth, lead upto 50m and lift upto 1.5m,
disposed earth to be levelled and neatly
dressed. (No extra lift is payable if work is
done by mechanical means)

2.6.1 All kinds of soil. Cum 25033.1 116.10 29,06,340


S.No S.O.R No.
Description Unit Qty Rate Amount

5 2.7 Earth work in excavation/ by mechanical


means (Hydraulic Excavator)/ manual
means over areas (exceeding 30 cm in
depth, 1.5m in width as well as 10 sqm on
plan) including dressing of sides and
ramming of bottom disposal of excavated
earth, lead upto 50 m and lift upto 1.5 m,
disposed earth to be levelled and neatly
dressed.

2.7.1 Ordinary rock cum. 6258.3 182.70 11,43,387


6 2.8 Earth work in excavation by mechanical
means (Hydraulic Excavator)/ manual
means in foundation trenches or drains
(not exceeding 1.5 m in width or 10 sqm on
plan) including dressing of sides and
ramming of bottoms, lift upto 1.5 m,
including getting out the excavated soil and
disposal of surplus excavated soil as
directed, within a lead of 50 m. (No extra
lift is payable if work is done by mechanical
means)

2.8.1 All kinds of soil. Cum 79171.5 117.90 93,34,321


7 2.9 Excavation work by mechanical means
(Hydraulic excavator) / manual means in
foundation trenches or drains not
exceeding 1.5 m in width or 10 sqm on plan
including dressing of sides and ramming of
bottoms lift upto 1.5 m, including getting
out the excavated soil and disposal of
surplus excavated soils as directed, within a
lead of 50m.
2.9.1 Ordinary rock cum. 16694.4 194.40 32,45,395
8 2.10 Excavating trenches of required width for
pipes, cables, etc including excavation for
sockets, and dressing of sides, ramming of
bottoms, depth upto 1.5 m including
getting out the excavated soil, and then
returning the soil as required, in layers not
exceeding 20 cm in depth including
consolidating each deposited layer by
ramming, watering, etc. and disposing of
surplus excavated soil as directed, within a
lead of 50 m : (No extra lift is payable if
work is done by mechanical means)

2.10.1 All kinds of soil


2.10.1.2 Pipes, cables etc. exceeding 80 mm dia. but
Meter 2994.0 140.40 4,20,358
not exceeding 300 mm dia.
S.No S.O.R No.
Description Unit Qty Rate Amount

9 2.25 Filling available excavated earth (excluding


hard rock/Ordinary rock) in trenches,
plinth, sides of foundations etc. in layers
not exceeding 20cm in depth, consolidating Cum. 12731.8 64.80 8,25,020
each deposited layer by ramming and
watering, lead up to 50 m and lift upto 1.5
m.
10 2.26 Extra for every additional lift of 1.5 m or
part thereof in excavation. (No extra lift is
payable if work is done by mechanical
means)
2.26.1 All kinds of soil. Cum. 70369.7 27.00 18,99,981
2.26.2 Ordinary or hard rock. cum. 16724.5 47.70 7,97,758
11 2.27 Supplying and filling in plinth with crusher
stone dust / coarse sand under floors
including, watering, ramming consolidating
in layers not exceeding 20cm in depth and cum. 6812.7 604.80 41,20,339
dressing complete. Note-maximum
thickness of this layer to be provided shall
be 20 cm.
12 2.28 Supplying and filling in plinth with hard
muram/hard copra under floors including
watering ramming cosolidating in layers not
exceeding 20cm in depth and dressing
complete.
2.28.1 Supplying and filling in plinth with hard
muram/hard copra having MDD not less
than 2.0 tim3 under floors including
watering, ramming and compacting
(minimum compaction 95% of MDD) in
Cum. 6670.7 270.00 18,01,080
layers not exceeding 20cm in thickness and
dressing complete. (Note-maximum
thickness of this layer to be provided shall
be 30cm.)

13 2.32 Preconstruction antitermite treatment to


the building under construction by
providing
Stage 1: Treating the bottom and the sides
(upto 30cm hight of the excavated trench
@ 5 litter per sqm of the surface area.

Stage 2: After masonry/RCC work, the


backfill in the immdiate contact with the
foundation structure treatment @ 7.5 litter
per sqm. of the vertical surface of the
substructure for each side.
S.No S.O.R No.
Description Unit Qty Rate Amount

Stage 3: surface treatment by spreading


emulsion over the plinth area before laying
the base concrete under floors @ 5.0
litres/Sqm.
Stage 4: Pumping the emulsion in plinth
masonry on filling side at floor junction @
7.5 litres/Sqm.
Stage 5: Pumping the emulsion from outer
side of the plinth below ground alround the
masonry @ 5.0 litres/Sqm as per I.S. 8944
Emulsion. (1Chlorpyrifos: 19 water) with
Sqm 24696.9 122.40 30,22,898
five years service guarantee
(Measurements to be taken for plinth area)

Note – Treatment should start when


foundation trenches and pits are ready to
take bed concrete or leveling course in
foundations. Laying of bed concrete should
start when the chemical emulsion has been
absorbed by the soil and the surface is
reasonably dry. Treatment should not be
carried out when it is raining or when soil is
wet with rain or subsoil water. This also
applies to filled up soil within the plinth
area before laying the subgrade for
flooring.

14 4.3 Centering and shuttering including


strutting, propping etc. and removal of
form work for :
4.3.1 Foundations, footings, bases for columns.
Sqm. 1155.1 152.10 1,75,697
15 4.1 Providing and laying in position cement
concrete of specified grade excluding the
cost of centering and shuttering - All work
up to plinth level :

4.1.1 With 20mm nominal size graded stone


aggregate.
4.1.1.4 Nominal Mix -1 Cement : 3 sand : 6 graded
cum 847.9 3,501.00 29,68,498
stone aggregate (M 10)
4.1.2 With 40mm nominal size graded stone
aggregate.
4.1.2.1 M 15 - Grade concrete cum 6032.7 3,962.70 2,39,05,931
4.1.2.2 Nominal Mix -1 Cement : 3 sand : 6 graded
Cum 1325.1 3,427.20 45,41,239
stone aggregate (M 10)
S.No S.O.R No.
Description Unit Qty Rate Amount

16 4.2 Providing and laying cement concrete in


retaining walls, return walls, walls (any
thickness) including attached pilasters,
columns, pillars, posts, struts, buttresses,
string or lacing courses, parapets, coping,
bed blocks, anchor blocks, plain window
sills, fillets etc. up to floor two level,
excluding the cost of centering, shuttering
and finishing :

4.2.1 With 20mm nominal size graded stone


aggregate
4.2.1.3 M 15 – Grade concrete cum 13.5 4,242.60 57,148
17 5.9 Centering and shuttering including
strutting, propping etc. and removal of
form for :
5.9.1 Foundations, footings, bases of columns,
etc. for concrete up to plinth level. Sqm. 104.6 156.60 16,387

5.9.2 Walls (any thickness) including attached


pilasters butteresses, plinth beams and
Sqm. 112.8 240.30 27,106
string courses etc.up to plinth level.

5.9.20 Suspended floors, roofs, landings, balconies


and access platform. with water proof ply
12mm thick. (item to be executed with
prior permission of S.E. in case of B & R sqm 82.6 342.90 28,330
works and from Additional Project Director
in case of PIU works)

5.9.21 Lintels, beams, columns, girders,


bressumers and cantilevers with water
proof ply 12mm thick (item to be executed
with prior permission of S.E. in case of B & sqm 182.8 308.70 56,437
R works and from Additional Project
Director in case of PIU works)

5.9.19 Weather shade, Chajjas, corbels etc.,


Sqm. 6.5 405.90 2,630
including edges.
18 5.1 Providing and laying in position specified
grade of reinforced cement concrete (with
20mm nominal size graded stone
aggregate) excluding the cost of centering,
shuttering, finishing and reinforcement - All
work up to plinth level :

5.1.1 M 20 –Grade Concrete Cum 14.6 4,581.90 66,804


S.No S.O.R No.
Description Unit Qty Rate Amount

19 5.2 Reinforced cement concrete work (with


20mm nominal size graded stone
aggregate) in walls (any thickness),
including attached pilasters, buttresses,
plinth and string courses, fillets, columns,
pillars, posts and struts etc. above plinth
level and up to floor two level excluding
cost of centering, shuttering, finishing and
reinforcement :

5.2.1 M 20 –Grade Concrete Cum 14.8 4,681.80 69,244


20 5.3 Reinforced cement concrete work (with
20mm nominal size graded stone
aggregate) in beams, suspended floors,
roofs having slope of any degree landings,
balconies, shelves, chajjas, lintels, bands,
plain window sills, staircases and spiral stair
cases above plinth level and up to floor two
level excluding the cost of centering,
shuttering, finishing and reinforcement in
concrete grade.

5.3.1 M 20 –Grade Concrete Cum 22.7 4,755.60 1,08,095


21 5.12 Providing precast cement concrete Jali
1:2:4 (1 cement : 2 sand : 4 graded stone
aggregate 6mm nominal size) reinforced
with 1.6 mm dia mild steel wire including
centring and shuttering, roughening
cleaning, fixing and finishing in cement
mortar 1:3 (1 cement: 3 sand) etc.
complete excluding plastering of the jambs,
sills and soffits.

5.12.1 50 mm thick sqm 7.8 711.00 5,532


S.No S.O.R No.
Description Unit Qty Rate Amount

22 5.44 RCC With Shuttering Providing and laying


Erecting Design Mix in Situ or Precast or
Combination of In situ and Precast Cement
Concrete of Specified Grade As Per
Approved Design For RCC Work Prepared
By Only Weigh, Batching, And Machine Mix
At Site / Yard / RMC Plant Including
Transportation To Any Lead By Any Mean
Such As Chute, Convyor Belt, Truck, RMC
Transist Mixer etc. Placed / Erected By Any
Mechanical Mean Sch As Bucket, Hoist,
Pump, Crane, Hydra etc. Including Cost of
All Materials Such As Admixture / Plasticizer
To Achive Designed Retarded / Accelerate /
Setting Time And Suitable Workability,
Centering, Shuttering, Strutting,
Compacting, Vibrating, Vaccume
Dewatering, Curing, ByANy Mean Such as
Water, Steam, Curing Compound etc.
Comlpete But Excluding Cost of
Reinforcement As Per Direction of Engineer
In Charge. All Works In Compliance To
Relavent IS Codes And CPWD Specification
Only.

(Note :Design Mix Shall Have Minimum


Cement Content Shall Be 325kg/Cum For M
20, 330kg/Cum For M 25, 340kg/Cum For M
30, 350kg/Cum For M 35, 360kg/Cum For M
40. and No Extra Payment For Use of Extra
Qty of Cement I Design Mix Shall Be Made.

5.44.1 All works upto plinth level.(Footing,Raft,


Pedestal, RCC Drain, RCC Retaining Wall,
RCC Abutments, RCC Piers, Plinth Beam,
Grade Slab, Curtain Wall, Poles, RCC Barrier
etc.)

5.44.1.1 M 20 cum 2639.2 5,000.00 1,31,95,975


5.44.1.2 M 25 cum 26673.5 5,210.00 13,89,69,141
5.44.1.5 M 40 cum 801.1 5,704.00 45,69,417
23 5.46 Add extra for work as per item 5.44.3,
5.44.4, 5.44.5, & 5.44.6 for additional
height in centering shuttering erecting
where ever required with adequate bracing
, proping etc. including deshuttering and cum 200.0 346.00 69,200
decentering at all levels over a height of 4
meters , for every additional height of 1 m
or part there of
S.No S.O.R No.
Description Unit Qty Rate Amount

24 5.16 Reinforcement for R.C.C. work including


straightening, cutting, bending, placing in
position and binding including cost of
binding wire up to floor two level including
all wastage etc. complete.

5.16.6 Thermo-Mechanically Treated bars.(TMT)


Kg. 18149188.2 60.00 1,08,89,51,290
25 5.17 Add extra for providing reinforcement
above Floor two level for every additional Kg.
floor or part there of.
1st Floor 1420045.0 0.18 2,55,608
2nd Floor 1420045.0 0.36 5,11,216
3rd Floor 1420045.0 0.54 7,66,824
4th Floor 1418430.4 0.72 10,21,270
5th Floor 1418430.4 0.90 12,76,587
6th Floor 1418430.4 1.08 15,31,905
7th Floor 1418430.4 1.26 17,87,222
8th Floor 1418430.4 1.44 20,42,540
9th Floor 1418430.4 1.62 22,97,857
Mumty 1340898.4 1.80 24,13,617
40723.0 1.98 80,632
26 5.24 Providing for plaster drip course/ groove in
plastered surface or moulding to R.C.C. RM 2200.0 16.65 36,630
projections.
27 5.44.2 Above Plinth Upto Floor Two Level
Walls(Any Thickness, Column, Pillars, Piers,
Posts, & Struts etc.
28 5.44.2.1 M 20 Cum 89.2 5,270.00 4,69,873
29 5.44.2.2 M 25 cum 9987.8 5,420.00 5,41,33,659
30 5.44.2.5 M-40 cum 9165.2 5,896.00 5,40,38,078
31 5.44.3 Suspended Roof, Roof Having Slope of
AnyDegree, Landings, Balconies, Access
Plateform, Floor Beam, Girders, Bressumers
And Cantilever Shleves, Chajjas, Lintels,
Bends, Staircases & Spiral Staircases, Coffer
Slab.
5.44.3.2 M 25 Cum 50213.4 5,480.00 27,51,69,199
32 5.44.5 Arches, Arch Ribs, Domes, Vaults, Shells,
Folded Plate
5.44.5.2 M 25 Cum 42.7 6,586.00 2,81,156
33 5.32 Extra For RCC Work Above Floor Two Level
1% of
For Each Floor or Part There of Cum
Respective Item
For Item No. 5.44.2.2
1st Floor 610.9 54.20 33,110
2nd Floor 610.9 108.40 66,219
3rd Floor 610.9 162.60 99,329
4th Floor 610.9 216.80 1,32,439
5th Floor 610.9 271.00 1,65,548
6th Floor 610.9 325.20 1,98,658
S.No S.O.R No.
Description Unit Qty Rate Amount

7th Floor 610.9 379.40 2,31,768


8th Floor 610.9 433.60 2,64,878
9th Floor 610.9 487.80 2,97,987
Mumty 85.3 542.00 46,222
For Item No. 5.44.3.2
1st Floor 6539.5 54.80 3,58,365
2nd Floor 6539.5 109.60 7,16,730
3rd Floor 6539.5 164.40 10,75,094
4th Floor 6531.2 219.20 14,31,644
5th Floor 6531.2 274.00 17,89,555
6th Floor 6531.2 328.80 21,47,466
7th Floor 6531.2 383.60 25,05,377
8th Floor 6531.2 438.40 28,63,288
9th Floor 6531.2 493.20 32,21,199
Mumty 6539.2 548.00 35,83,494
184.9 602.80 1,11,431
For Dome
Above Ninth Floor 42.7 724.46 30,927
34 5.34 Providing and fixing in position factory
made precast RCC M-40 doors and
windows frames having excellent smooth
finish as per IS: 6523 with reinforcement of
3 Nos, 6 mm dia main bars tied with 3 mm
M.S stirrups placed @ 200 mm C/C and 6
numbers high strength polymer blocks of
required size for fixing hinges including
providing 6 no specially designed M.S.
galvanised sleeves for accomodating 6 mm
dia fully threaded bolts for fixing hold fast
on vertical members, providing suitable
arrangement for recieving sliding door bolts
and tower bolt etc all complete, as per the
direction of Engineer in charge. (The cost of
hold fast and Cement Concrete block of
1:3:6 (1 Cement : 3 sand : 6 Graded stone
agreegate 20mm nominal size) mix is also
included in the item.) The frame shall be
measured in running meter correct to two
places of decimal.

5.34.1 Door frame 125mmx 60 mm RM 2495.4 315.90 7,88,297


S.No S.O.R No.
Description Unit Qty Rate Amount

35 6.28 Autoclaved Aerated Concrete (ACC) Blocks


Masonry : - Providing & Laying Autoclaved
Aerated Concrete (AAC) Bock Masonry,
Using AAC Blocks (Size in mm Length
400,500,600 Height 200, 250, 300 Width
100, 150, 200, 250) Confirming To IS 2185
Part 3, Having Compressive Strength not
Less Than 3MPa ( Grade II )in Super
Structure, Block Jointed With Cement
Moetar 1:6 (1 Cement: 6 Sand) or With
Polymer Modified Cement Mortar (Make
Such As Magicrete, Fairmate, Ball Endura,
Letecrete, CI or Equivalent) As Per ASTMC
1660-09, Applied in Uniform Thickness of 2
to 3mm in Horizontal And Vertical Joints
Using Special Trovel, Polymer Modified
Mortar Having Minimum Compressive
Strength & Minimum Splitting Tensile
Strength of Not Less Than 5MPa and 0.34
MPa Respectively as Per ASTM
International Standard Including Racking
out Jointh.

The Surface of Masonry Units(AAC-Block)


Should Be Slightly Moidt Prior to
Application of Jointing Mortar. Block Should
Be Gently Pressed Down a Rubber Mallet
To Expel Out Entrapped Air and The
Masonry Shall Be Cured For Seven Days For
Cement Mortar and Two Days For Polymer
Modified Mortar. 1st layer of Masonry
Block Shall BE Placed on Perfectly Leveled
Surface, Which If Required, Shall Be Laveled
With M-20 Cement Concrete at Plinth or
Floor Level. Msonry Shall Have 80mm Thick
RCC Band With M-20 Cement Concreye And
2 Bars of 8mm Dia. Such Bands Shall Be
Spaced At Interval of Maximum 1.8 Meter
In Vertical Direction And Maximum 4.5
Meter in Horizontal Direction. RCC Band
Shall Be MeasuredWith AAC Block Masonry.
Rates Including All Materials Including Steel
Bars, Wastages, Scaffolding And All Labour
etc. Complete.

6.28.2 AAC Masonary in Polymer Modified mortar


cum 26951.9 5,157.00 13,89,90,701
S.No S.O.R No.
Description Unit Qty Rate Amount

36 6.29 Extra for AAC Masonry Work As Per Item


No. 6.28 in Super Structure Above Floor
Two Level For Each Additional Floor or Part
There of.
1st Floor Cum 2608.3 72.00 1,87,795
2nd Floor Cum 2617.2 144.00 3,76,878
3rd Floor Cum 2579.1 216.00 5,57,090
4th Floor Cum 2543.0 288.00 7,32,388
5th Floor Cum 2543.0 360.00 9,15,485
6th Floor Cum 2543.0 432.00 10,98,582
7th Floor Cum 2543.0 504.00 12,81,680
8th Floor Cum 2527.1 576.00 14,55,630
9th Floor Cum 2188.8 648.00 14,18,359
Parapet Cum 7.7 720.00 5,508
Mumty Cum 992.3 720.00 7,14,470
37 7.40 Providing and fixing dry cladding upto 10
metre heights with 30mm thick gang saw
cut stone with (machine cut edges) of
uniform colour and size upto 1mx1m, fixed
to structural steel frame work and/ or with
the help of cramps, pins etc. and sealing
the joints with approved weather sealant as
per Architectural drawing and direction of
Engineer-in-charge. (The steel frame work,
stainless steel cramps and pins. shall be
paid for separately.)

7.40.2 White sand stone sqm 11060.5 1,535.40 1,69,82,292


38 7.25 Providing and fixing stainless steel cramps
of required size and shape for anchoring
stone wall lining to the backing or securing
adjacent stones in stone wall lining in
kg 22295.9 567.90 1,26,61,842
cement mortar 1:2 (1 cement :2 sand)
including making the necessary chases in
stone and holes in walls wherever required.

39 7.26 Providing and fixing stone dowels of size


10x5x2.5cm cut to double wedge shape as
per design in cement mortar 1:2 (1 cement each 110604.0 31.50 34,84,026
: 2 sand) including making the necessary
chases
40 7.27 Providing and fixing copper pins 7.5 cm
long 6 mm diameter for securing adjacent
stones in stone wall lining in cement mortar each 265450.0 31.50 83,61,675
1:2 (1 cement : 2 sand) including making
the necessary chases.
S.No S.O.R No.
Description Unit Qty Rate Amount

41 7.33 Providing and fixing stone jali 40mm thick


throughout in cement mortar 1:3
(1cement :3 sand) including pointing in
white cement mortar 1:2 (1white cement:
2stone dust) with an admixture of pigment
, matching the stone shade, jali slab
without any chamfers etc

7.33.2 White sand stone sqm 4918.8 5,217.30 2,56,62,855


42 7.37 Stone work ( machine cut edges) for wall
lining upto 10 m height etc. (Veneer work)
backing filled with a grout of 12mm thick
cement mortar 1:3 (1 Cement : 3 sand) and
jointed with Cement mortar 1:2 (1 cement
: 2 marble dust) including rubbing and poli
shing complete. (To be secured to the
backing by means of cramps which shall be
paid for separately)

7.37.2 25mm thick Dholpur stone slabs exposed


sqm 105.0 1,322.10 1,38,821
face dressed and rubbed.
43 8.8 "Design supply and installation of
suspended Spider Glazing system designed
to withstand the wind pressure as pr IS 875
(Part-III). The Suspended System held with
Spider Fittings of SS-316 Grade Steel of
approved manufacturer with glass panel
having 12 mm thick clear toughened glass
held together with SS- 316 Grade Stainless
steel Spider and bolt assembly with
laminated glass fins 21 mm thick. The Glass
fins and glass panel assembly shall be
connected to Slab/beams by means of SS- Sqm 1318.5 5,384.70 70,99,727
316 Grade stainless steel brackets and
Anchor bolts and at the bottom using SS
channel of 50x25x2mm using fastener and
anchor bolts, non staining weather sealants
of approved make, Teflon/ nylon bushes
and separators to prevent bi-metallic
contacts, all complete to perform as per
specification and approved drawings.
S.No S.O.R No.
Description Unit Qty Rate Amount

The complete system to be designed to


accommodate thermal expansion and
seismic movements etc. The joints between
glass panels (6 to 8 mm) and gaps at the
perimeter and in U channel of the assembly
to be filled with non staining weather
sealant, so as to make the entire system
fully water proof and dust proof. The rate
shall include all design, Engineering and
shop drawing including approval from
structural designer, labour, TandP,
scaffolding , other incidental charges
including wastage, enabling temporary
services all fitting fixers nut bolts, washer,
Buffer plates, fastener, anchors, SS channel
laminated glass etc. all complete. For the
purpose of payment, actual elevation area
of Glazing including thickness of joints and
the portion of Glass panel inside the SS
channel shall be measured."

9.1 Providing wood work in frames of doors,


windows, clerestory windows and other
frames, wrought framed and fixed in
position with hold fast lugs or with dash
fasteners of required dia and length (hold
fast lugs or dash fastener shall be paid for
separately).
44 9.1.4 Factory made Kiln seasoned and chemically
treated Finger jointed at spacing not closer
50 cm , second class hard wood.

9.1.4.1 frame of sizes 100 x 60 mm single or double


Mtr 13116.8 389.00 51,02,427
rebated
45 9.6 Providing and fixing panelling or panelling
and glazing in panelled or panelled and
glazed shutters for doors, windows and
clerestory windows (Area of opening for
panel inserts excluding portion inside
grooves or rebates to be measured).
Panelling for panelled or panelled and
glazed shutters 25 mm to 40 mm thick :

9.6.7 Float glass panes


9.6.7.2 5.5 mm thick glass pane sqm 6059.0 941.40 57,03,933
S.No S.O.R No.
Description Unit Qty Rate Amount

46 9.193 PROVIDING and fixing ISI marked factory made


flush door shutters conforming to IS: 2202 (part
1) laminated type, core of block board
constrution with kiln seasoned and chemically
treated 2nd class hard wood battens (strips)
and frame of kiln sensoned and chemically
treated, finger jointed 1st class hard wood of
width not less than 65mm for style, top rail,
bottom rail and 125mm for lock rail. block
board shall be provided with well matched 3mm
thick commercial 3 ply veneering consisting of
vertical grains, cross bands and commercial
grade face venners on both outer faces of
shutters including kiln seasoned and chemically
treated ,finger jointed 2nd class teakwood
internal lipping (battens) fixed in factory by
using pneumating gun, of depth not less than
25mm on all edges of shutters, spacing of finger
joints in wood as above shall not be lass than
50cm.

both surfaces of shutters to be provided with


1.00mm thick decorative high pressure
laminated sheet on plain/wood grain in
gloss/matt/suede finish with high density
protective surface layer of make such as mica,
century, greenlam,formica,durian or equivalent
thereby not requiring polish,putty or painting
work,adhesive on reverse side of lamination
sheet shall be factory made to the exact size
(opening) within frame of doors/ cupboards and
shall be stamped by the manufacturer to display
name of manufacture, batch number of product
and conformity with IS:2202. the rate shall be
inclusive of all material and labour complete
and as per specification and direction of
engineer-in-charge.
9.193.2 30mm thick including 3nos. 100mm long, ISI
marked heavy weight (2.5mm thick) stainless sqm 6336.3 3,171.00 2,00,92,360
steel butt hinges with necessary screws.

47 9.43 Providing and fixing M.S. grills of required


pattern in frames of windows etc. with M.S.
flats, square or round bars etc. including
priming coat with approved steel primer all
complete.
9.43.2 Fixed to openings /wooden frames with
Kg. 70666.9 90.00 63,60,021
rawl plugs screws etc.
48 9.65 Providing and fixing ISI marked stainless
steel sliding door bolts with nuts and
screws etc. complete :
9.65.2 250x16 mm Each 4619.0 293.40 13,55,215
S.No S.O.R No.
Description Unit Qty Rate Amount

49 9.66 Providing and fixing ISI marked stainless


steel tower bolt black finish, (Barrel type)
with necessary screws etc. complete

9.66.2 200x10 mm Each 2895.0 83.70 2,42,312


50 9.69 Providing and fixing ISI marked stainless
steel handles with necessary screws etc.
complete :
9.69.1 125 mm Each 9148.0 54.00 4,93,992
51 9.168 Providing and fixing factory made panel
PVC door shutter consisting of frame made
out of M.S. tubes of 19 gauge thickness and
size of 19mm x 19mm for styles and
15x15mm for top and bottom rails. M.S.
frame shall have a coat of steel primers of
approved make and manufacture . M.S.
frame covered with 5mm thick heat
moulded PVC 'C' channel of size 30mm
thickness, 70mm width out of which 50mm
shall be flat and 20mm shall be tapered in
45degree angle on both side forming styles;
and 5mm thick, 95mm wide PVC sheet out
of which 75mm shall be flat and 20mm
shall be tapered in 45 degree on the inner
side to form top and bottom rail and
115mm wide PVC sheet out of which 75mm
shall be flat and 20mm shall be tapered on
both sides to form lock rail.

Top, bottom and lock rails shall be


provided both side of the panel. 10mm
(5mmx2) thick, 20mm wide cross PVC sheet
be provided as gap insert for top rail and
bottom rail. paneling of 5mm thick both
side PVC sheet to be fitted in the M.S.
frame welded/ sealed to the styles and rails
with 7mm (5mm+2mm) thick x 15mm wide
PVC sheet beading on inner side, and joined
together with solvent cement adhesive. An
additional 5mm thick PVC strip of 20mm
width is to be stuck on the interior side of
the 'C' Channel using PVC solvent adhesive
etc. complete as per direction of Engineer-
in-charge. Manufacturer’s specification and
drawing.

9.168.2 30 mm thick pre laminated PVC door


sqm 602.1 3,400.20 20,47,260
shutters.
S.No S.O.R No.
Description Unit Qty Rate Amount

52 9.181 Providing and Fixing factory made uPVC


door frame made of uPVC exturded
sections, of size 65 mmx55 mm with wall
thickness 2.0 mm (±0.2 mm), corners of the
door frame to be mitred cut and jointed
with plastic brackets and stainless steel
screws, reinforcing hinge side vertical of the
frames with PVC profile of Size 28 mmx30
mm having wall thickness 2 mm (±0.2mm),
meter 920.0 391.50 3,60,180
including providing and fixing 3 nos. of 125
mm long stainless steel hinges to the
frame, fixing the frame with jamb with
required number and size of anchor dash
fastners, all complete as per
manufacturer's specification and direction
of Engineer-in-charge.

53 9.182 Providing and Fixing, uPVC factory made,


white colour casement/sliding window
and door made of extruded profiles.
Profiles of frames and sash will be mitered
cut and fusion welded at all corners
including drilling of holes for fixing
hardware and drainage of water etc.,
making arrangement for fixing of hardware,
EPDM gasket, 1.2 ± 0.2mm thick galvanised
steel profile to be inserted in required
profile, frame will be fixed to the wall with
8 mmx100 mm long fasteners, all complete
as per direction of Engineer-in-charge.
(Glazing, hardware hinges and fitting etc. to
be paid separately.)

9.182.3 Sliding Window (Two Track, 2/4 Shutters)

9.182.3.1 Two Track Sliding Frame (67mm x 52mm)


metre 12037.6 509.40 61,31,953
9.182.3.2 Sliding window Sash (60mm x 44mm) metre 16725.8 476.10 79,63,153
9.182.3.3 Sliding Interlock for Window (one vertical
length in each shutter)(45.5 mm x 28 mm) metre 2247.6 125.10 2,81,175

9.182.3.4 Sliding Glazing bead (35 mm x 18 mm) metre 12952.8 160.20 20,75,039
54 9.184 Providing and fixing casement handle made
of zinc alloyed (white powder coated) for
each 3080.0 192.60 5,93,208
uPVC casement window with necessary
screws etc. complete.
55 9.185 Providing and fixing zinc alloyed (white
powder coated) touch lock for uPVC sliding
each 1615.0 129.60 2,09,304
window with necessary screws etc.
complete.
S.No S.O.R No.
Description Unit Qty Rate Amount

56 9.186 Providing and fixing steel roller for uPVC


sliding window with necessary screws etc. each 4569.0 66.60 3,04,295
complete.
57 10.5 Providing and fixing 1mm thick M.S. sheet
door with frame of 40x40x5mm angle iron
and 3mm M.S. gusset plates at the
junctions and corners, all necessary fittings
complete, including applying a priming coat
of approved steel primer.

10.5.1 Using M.S. angels 40x40x6mm for diagonal


Sqm. 9.8 2,344.14 22,902
braces
58 10.6 Supplying and fixing rolling shutters of
approved make, made of required size M.S.
laths interlocked together through their
entire length and jointed together at the
end by end locks mounted on specially
designed pipe shaft with brackets, side
guides and arrangements for inside and
outside locking with push and pull
operation complete including the cost of
providing and fixing necessary 27.5cm long
wire springs manufactured from high
tensile steel wire of adequate strength
conforming to I.S. 4454- part-1 and M.S.
top cover of required thickness for rolling
shutters.

10.6.1 80x1.25mm M.S. laths with 1.25 mm thick


sqm 75.6 1,980.09 1,49,695
top cover
59 10.22 Steel work welded in built up sections/
framed work including cutting, hoisting,
fixing in position and applying a priming
coat of approved steel primer using
structural steel etc. as required.

10.22.2 In gratings, frames, guard bar, ladder,


railings, brackets, gates and similar works. Kg 34642.0 76.59 26,53,231
S.No S.O.R No.
Description Unit Qty Rate Amount

60 10.25 Providing and fixing stainless steel ( Grade


304) railing made of Hollow tubes,
channels, plates etc. including welding,
grinding, buffing, polishing and making
curvature (wherever required) and fitting
the same with necessary stainless steel
nuts and bolts complete i/c fixing the railing
with necessary accessories and stainless
steel dash fasteners , stainless steel bolts
etc., of required size, on the top of the Kg. 117464.3 714.38 8,39,13,585
floor or the side of waist slab with suitable
arrangement as per approval of
Engineer-in-charge. ( for payment purpose
only weight of stainless steel members shall
be considered excluding fixing accessories
such as nuts, bolts, fasteners etc.)

61 10.15 Steel work in built up tubular ( round,


square or rectangular hollow tubes etc.)
trusses/frame work etc. including cutting,
hoisting, fixing in position and applying a
priming coat of approved steel primer,
including welding and bolted with special
shaped washers etc. complete.

10.15.1 Hot finished welded type tubes kg 80075.0 97.07 77,72,480


62 10.36 Providing and fixing concertina coil fencing
with punched tape concertina coil 600 mm
dia 10 metre openable length ( total length
90 m), having 50 nos rounds per 6 metre
length, upto 3 m height of wall with existing
angle iron 'Y' shaped placed 2.4

m or 3.00m apart and with 9 horizontal


R.B.T. reinforced arbed wire, stud tied with
G.I. staples and G.I. clips to retain
horizontal, including necessary bolts or G.I.
barbed wire tied to angle iron, all complete
as per direction of Engineer-incharge,

with reinforced barbed tape(R.B.T.) / Spring


core (2.5 mm thick) wire of high tensile
strength of 165 kg/ sq mm with tape (0.52
Metre 275.0 247.50 68,063
mm thick) and weight 43.478 gm/ metre
(cost of M.S. angle, C.C. blocks shall be paid
separately).
S.No S.O.R No.
Description Unit Qty Rate Amount

63 11.22 Providing and fixing 18mm thick gang saw


cut mirror polished (premoulded and
prepolished) machine cut for kitchen
platforms, vanity counters, window sills ,
facias and similar locations of required size
of approved shade, colour and texture laid
over 20mm thick base cement mortar 1:4
(1 cement : 4 sand) with joints treated with
white cement, mixed with matching
pigment, epoxy touch ups, including
rubbing, curing moulding and polishing to
edge to give high gloss finish wherever
required etc. complete at all levels. samples
approved by Engineer-in-charge.

11.22.2 Granite of any colour and shade Sqm. 3617.9 2,989.80 1,08,16,812
64 11.29 Providing and laying gang saw cut 18 mm
thick, mirror polished pre moulded
(wherever required) and pre polished
machine cut granite stone of required size
and shape of approved shade, colour and
texture in flooring laid over 20mm thick
base of cement mortar 1:4 (1cement : 4
sand) including grouting the joints with
white cement mixed with matching
pigment, epoxy touch ups etc. complete as
per direction of Engineer-in-Charge.

11.29.1 Area of slab over 0.50 sqm.


11.29.1 Fine Grained Dark Black/ Dark Red/ White
With Self Design/ attern/ Crystal of Other Sqr 18098.8 2,142.00 3,87,67,619
Colors & Glotter
11.29.1.3 Gray/ Pink/Brown With Various Pattern
Sqm. 25469.1 1,653.30 4,21,08,137
65 11.33 Pre polished Granite stone work 18mm
thick of any colour in riser of steps, skirting,
dado and pillars laid on 12 mm average
thick cement mortar 1:3 (1 cement:3 sand) Sqm 11436.3 3,071.70 3,51,28,975
and jointed with white cement slurry mixed
with pigment to match the shade of slab.

66 11.34 Kota stone slab flooring over 20 mm


(average) thick base laid over and jointed
with grey cement slurry mixed with
pigment to match the shade of the slab
including rubbing and polishing complete
with base of cement mortar 1 : 4 (1 cement
: 4 sand) :

11.34.1 25 mm thick. Sqm 76050.6 688.50 5,23,60,838


S.No S.O.R No.
Description Unit Qty Rate Amount

67 11.35 Kota stone slabs 20 mm thick in risers of


steps, skirting, dado and pillars laid on 12
mm (average) thick cement mortar 1:3 (1
cement 3 sand) and jointed with grey
Sqm 5588.2 668.70 37,36,816
cement slurry mixed with pigment to match
the shade of the slabs, including rubbing
and polishing complete.

68 11.38 Extra for providing opening of required size


and shape for wash basins/ kitchen sink in
kitchen platform, vanity counters and
similar location in marble/Granite/stone
each 488.0 208.80 1,01,894
work including necessary holes for pillar
taps etc. including moulding, rubbing and
polishing of cut edges etc. complete.

69 11.51 Providing and laying rectified Glazed


Ceramic floor tiles 300x300 mm or more
(having thickness 9 to 10mm) of 1st quality
conforming to IS : 15622 of approved make
in all colours, shades, except White, Ivory,
Grey, Fume Red Brown, laid on 20 mm Sqm 5847.3 589.50 34,46,989
thick Cement Mortar 1:4 (1 Cement : 4
sand) including pointing the joints with
white cement and matching pigments etc.,
complete.

70 11.52 Providing and laying rectified Glazed


Ceramic wall tiles 300x450 mm or more
(thickness to be specified by the
manufacturer) of 1st quality conforming to
IS : 15622 of approved make in all colours,
shades, except White, Ivory, Grey, Fume Sqm 10484.3 644.40 67,56,076
Red Brown, laid on 12 mm thick Cement
Mortar 1:3 (1 Cement : 3 sand) including
pointing the joints with white cement and
matching pigments etc., complete.
S.No S.O.R No.
Description Unit Qty Rate Amount

71 11.66 Crazy ceramic tile flooring, with under layer


12 mm thick cement mortar 1:4 (1
cement: 4 sand), with joints not
exceeding 5 mm, including filling the gaps
with ordinary cement mixture and mixing
with synthetic polyester fibre, triangular in
shape having specific gravity of 1.34 to
1.40, cross section size ranging from 10 to
sqm 10472.8 324.00 33,93,174
40 micron and length upto 6 mm , mixing
fibre @ 125 grams per 50 kg of cement in
cement mortar, including providing and
mixing water proofing material in mortar @
1 kg per 50 kg of cement , all complete as
per direction of Engineer- in-charge.

72 11.90 Providing and laying Vitrified Floor tiles


Multi/ Double Charge (Minimum Top Layer
Thickness 2.0 mm)Nano Polished Self
Design, In Different Size , with water
absorption less than 0.05% and conforming
to IS:15622 , of approved Make in All Colors
& Shades, 1st Quality / Premium In
Flooring, Laid on 20mm Thick Cement
Mortar 1:4 (1 Cement :4 Sand) Including
Grouting the Joint With White Cement &
MatchingPigment etc Complete.

11.90.1 In Light Shade Glossy/ Rustic / Satin


Finished
(a ) Size600x600mm Thickness 9-10mm sqm 5799.2 903.60 52,40,130
(c ) Size800x1200mm Thickness 11-12mm
sqm 70.0 1,181.70 82,719
73 11.91 Providing and laying Vitrified Floor tiles
Multi/ Double Charge (MinimumTop Layer
Thickness 2.0 mm)Nano Polished Self
Design, In Different Size , with water
absorption less than 0.05% and conforming
to IS:15622 , of approved Make in All Colors
& Shades, 1st Quality / Premium In Skirting,
Laid on 12mm Thick Cement Mortar 1:3 (1
Cement : 3 Sand) Including Grouting the
Joint With White Cement & Matching
Pigment etc Complete.

11.91.1 In Light Shade Glossy/ Rustic / Satin


Finished
(a ) Size600x600mm Thickness 9-10mm sqm 279.8 893.70 2,50,057
(b ) Size800x800mm Thickness 11-12mm
sqm 15488.7 1,000.80 1,55,01,091
S.No S.O.R No.
Description Unit Qty Rate Amount

(c ) Size800x1200mm Thickness 11-12mm


sqm 955.1 1,172.70 11,19,987
74 11.72 Providing and fixing stone slab table rubbed
on both faces edges rounded and polished
of size as required and 1.8 cm thick fixed in
urinal partitions by cutting a chase of
appropriate width with chase cutter and
embedding the stone in the chase with
epoxy grout or with cement concrete 1:2:4
(1 cement : 2 sand : 4 graded stone
aggregate 6 mm nominal size) as per
direction of Engineer-in-charge and finished
smooth.

11.72.2 Granite Stone of approved shade. sqm 191.5 3,079.80 5,89,843


75 11.84 Providing and laying at or near ground level
factory made kerb stone
of M-25 grade cement concrete in position
to the required line, level
and curvature, jointed with cement mortar
1:3 (1 cement: 3 sand), including making
joints with or without grooves (thickness of
joints except at sharp curve shall not to
more than 5mm), including making Cum 450.0 6,097.50 27,43,875
drainage opening wherever required
complete etc. as per direction of Engineer-
in-charge (length of finished kerb edging
shall be measured for payment). (Precast
C.C. kerb stone shall be approved by
Engineer-in-charge).

11.97 Providing and laying gang saw cut 12 mm


thick, mirror polished pre moulded
(wherever required) and pre polished
machine cut granite stone of required size
and shape of approved shade, colour and
texture in flooring laid over 20mm thick
base of cement mortar 1:4 (1cement : 4
sand) including grouting the joints with
white cement mixed with matching
pigment, epoxy touch ups etc. complete as
per direction of Engineer-in-Charge.

11.97.1 Area of Tile Not Less Than 0.18 Sqm


11.97.01.01 Fine Grained Dark Black/ Dark Red/ White
With Self Design/ Pattern / Crystal of Other Sqm 500.0 1,674.90 8,37,450
Colors or Glotter.
S.No S.O.R No.
Description Unit Qty Rate Amount

76 12.15 Providing and fixing precoated galvanised


iron profile sheets (size, shape and pitch of
corrugation as approved by Engineer-in-
charge) 0.50 mm + 0.05 %, total coated
thickness with zinc coating 120 gsm as per
IS: 277 in 240 mpa steel grade, 5-7 microns
epoxy primer on both side of the sheet and
polyester top coat 15-18 microns. Sheet
should have protective guard film of 25
microns minimum to avoid scratches while
transportation and should be supplied in
sqm 130.5 586.80 76,577
single length upto 12 metre or as desired by
Engineer-in-charge. The sheet shall be fixed
using self drilling /self tapping screws of
size (5.5x 55mm) with EPDM seal, complete
upto any pitch in horizontal/ vertical or
curved surfaces excluding the cost of
purlins, rafters and trusses and including
cutting to size and shape wherever
required.

77 12.18 Providing and Fixing of sky lights consisting


of Multi cell/tight cell Polycarbonate Panel
System of approved colour, 16 mm thick
(minimum) having uniform in color with an
integral Tight-Cell core constructed not to
exceed 4mmx4mm in a cross section,
Vertical Standing Seam manufactured at
both sides of the panel. Snap-on connector
to interlock the panels shall have a grip-lock
double tooth locking mechanism to ensure
maximum uplift capability and shall be of
same color as that of panel. Panel shall be
0
factory sealed/end welded panels with
additional End-cap/Aluminium U-Profile
(mill finish) for ends. Panel shall be co-
extruded with special anti glare compound
and UV protected. The full system shall be
fitted on MS purlins perpendicular to
direction of sheeting with purlin spacing as
specified by Manufacturer.
S.No S.O.R No.
Description Unit Qty Rate Amount

The rate includes cost of all the operations,


labour and all materials and tests (as
applicable) involved such as bolts nuts and
screws etc. and labour for cutting bending
to required profile, necessary scaffolding,
hoisting in position etc. for proper
completion of the work etc. complete as
per specification drawings and direction of
Engineer in charge. Finished surface area of
roofing fixed over steel tublar structure
shall be measured for payment. MS tabular
frame work shall be measured separately
for payment.

12.18.2 16mm thick sqm 3641.5 3,191.40 1,16,21,483


78 12.26 Providing gola 75x75 mm in cement
concrete 1:2:4 (1 cement : 2 sand : 4 stone
aggregate 10mm and down grade)
including finishing with cement mortar 1:3
(1 cement : 3 sand) as per standard design :

12.26.1 In 75x75mm deep chase meter 989.0 89.10 88,120


79 12.27 Making khurras 45x45 cm with average
minimum thickness of 5 cm cement
concrete 1:2:4 (1 cement : 2 sand : 4 graded
stone aggregate of 20 mm nominal size)
over P.V.C. sheet 1mx1mx400micron,
Each 149.0 140.40 20,920
finished with 12mm cement plaster 1:3 (1
cement : 3 sand) and a coat of neat cement
rounding the edge and making and
finishing the outlet complete.

80 12.28 Providing and fixing M.S. holder bat clamps


of approved design to C.I. or S.C.I. rain
water pipes embedded in and including
cement concrete blocks 10x10x10cm of
Cement Concrete 1:2:4 mix (1 cement : 2
sand : 4 graded stone aggregate 20 mm
nominal size) and cost of cutting holes and
making good the walls etc.

12.28.1 100 mm diameter each 30.0 96.30 2,889


12.28.2 150 mm diameter each 1090.0 100.80 1,09,872
81 12.29 Providing and fixing sand cast iron rain
water pipes.
12.29.1 100 mm dia minimum wall thickness 5mm
meter 50.0 783.90 39,195
12.29.2 150 mm dia minimum wall thickness 5mm
meter 2300.0 972.90 22,37,670
S.No S.O.R No.
Description Unit Qty Rate Amount

82 12.30 Providing lead caulked joints to sand cast


iron rain water pipes and fittings :
12.30.1 100 mm dia. Pipe each 23.0 198.90 4,575
12.30.2 150 mm dia. Pipe each 750.0 278.10 2,08,575
83 12.31 Providing, fixing and embedding sand cast
iron accessories for rain water pipes in the
masonry surrounded with 12 mm thick
cement mortar of the same mix, as that of
masonry (lead caulking will be paid for
separately) :
84 12.31.1 Sand cast iron bend :
12.31.1.1 150 mm diameter each 230.0 423.00 97,290
12.31.1.2 100 mm diameter each 18.0 344.70 6,205
85 12.31.2 Sand cast iron plain shoes :
12.31.2.1 150 mm diameter each 125.0 439.20 54,900
12.31.2.2 100 mm diameter each 9.0 370.80 3,337
86 12.32 Providing and fixing on wall face
Unplasticised Rigid PVC rain water pipes
conforming to IS : 13592 Type A including
jointing with seal ring conforming to IS :
5382 leaving 10 mm gap for thermal
expansion.
(i) Single socketed pipes
12.32.1 75 mm diameter (minimum wall thickness
each 30.0 122.40 3,672
1.8mm)
87 12.35 Providing and fixing to the inlet mouth of
rain water pipe cast iron grating 15 cm
Each 124.0 38.70 4,799
diameter and weighing not less than 440
grams.
S.No S.O.R No.
Description Unit Qty Rate Amount

88 12.62 Providing and fixing of Mineral Fibre


Acoustical Suspended Ceiling System with
16mm thick tegular edge tiles of size
595x595mm as approved by Engineer-in-
charge, in true horizontal level suspended
on inter locking metal grid of hot dipped
galvanized steel sections (galvanized @ 120
gsm/sqm, both side inclusive) consisting of
main "T" runner with suitably spaced joints
to get required length and of size 24x38mm
made from 0.30mm thick (minimum) sheet,
spaced at 1200mm center to center and
cross "T" of size 24x25mm made of
0.30mm thick (minimum) sheet, 1200mm
long spaced between main "T" at 600mm
center to center to form a grid of 1200x600
mm and secondary cross "T" of length
600mm and size 24x25mm made of 0.30
mm thick (minimum) sheet to be
interlocked at middle of the 1200x600mm
panel to form grids of 600x600mm and wall
angle of size 24x24x0.3 mm and laying false
ceiling tiles of approved texture in the grid
including,

wherever, required, cutting/making,


opening for services like diffusers, grills,
light fittings, fixtures, smoke detectors etc.
Main "T" runners to be suspended from
ceiling using GI slotted cleats of size
27x37x25x1.6 x mm fixed to ceiling with
12.5 mm dia and 50 mm long dash
fasteners, 4mm GI adjustable rods with
galvanised butterfly level clips of size
85x30x0.8 mm spaced at 1200mm center
to center along main T, bottom exposed
width of 24 mm of all T-sections shall be
pre-painted with polyester paint, all
complete for all heights as per
specifications drawings and as directed by
Engineer-in-charge.
S.No S.O.R No.
Description Unit Qty Rate Amount

The tiles should have Humidity Resistance


(RH) of 99%, NRC 0.5, Light Reflectance
≥83%, Thermal Conductivity k = 0.052 -
0.057 w/m K, Colour White, Fire
Performance UK Class 0 / Class 1 (BS 476 pt -
6 and7) in module size of 600 x 600 x 16mm
with Bio Block coating on the face of the sqm 21042.9 1,658.70 3,49,03,850
tile, suitable for Green Building application,
with Recycled content of 38 - 41%. The Tile
and Grid system used together should carry
a 15 year warranty.

89 12.46 Providing and fixing false ceiling at all


height including providing and fixing of
frame work made of special sections,
power pressed from M.S. sheets and
galvanized with zinc coating of 120
gms/sqm (both side inclusive) as per IS :
277 and consisting of angle cleats of size 25
mm wide x 1.6 mm thick with flanges of 27
mm and 37mm, at 1200 mm centre to
centre, one flange fixed to the ceiling with
dash fastener 12.5 mm dia x 50mm long
with 6mm dia bolts other flange of cleat
fixed to the angle hangers of 25x10x0.50
mm of required length with nuts and bolts
of required size and other end of angle
hanger fixed with intermediate G.I.
channels 45x15x0.9 mm running at the
spacing of 1200 mm centre to centre to
which the ceiling section 0.5 mm thick
S.No S.O.R No.
Description Unit Qty Rate Amount

bottom wedge of 80 mm with tapered


flanges of 26 mm each having lips of 10.5
mm, at 450 mm centre to centre, shall be
fixed in a direction perpendicular to G.I.
intermediate channel with connecting clips
made out of 2.64 mm dia x 230 mm long
G.I. wire at every junction, including fixing
perimeter channels 0.5 mm thick 27 mm
high having flanges of 20 mm and 30 mm
long, the perimeter of ceiling fixed to
wall/partition with the help of rawl plugs at
450 mm centre, with 25mm long dry wall
screws @ 230 mm interval, including fixing
of 10mm thick plaster of Paris (gypsum
anhydrous) sheet to ceiling section and
perimeter channels with the help of dry
wall screws of size 3.5x25mm at 230mm
interval including jointing

and finishing to a flush finish of tapered


and square edges of POP board with
jointing compound (POP paste) including
the cost of making openings for light
fittings, grills, diffusers cutouts made with
frame of perimeter channels suitably fixed
all complete as per drawing, specifications
and direction of the Engineer-in-charge.

12.46.1 Flat surfaces sqm 25964.0 608.40 1,57,96,524


90 13.1 12 mm cement plaster of mix :
13.1.2 1:6 (1 cement : 6 sand) Sqm. 210979.4 99.00 2,08,86,964
91 13.8 6 mm cement plaster of mix :
13.8.1 1:3 (1 cement : 3 sand) Sqm. 220343.7 86.40 1,90,37,698
92 13.9 6 mm cement plaster 1:3 (1 cement : 3
sand) finished with a floating coat of neat
cement and thick coat of Lime wash on top sqm 1630.7 117.00 1,90,798
of walls when dry for bearing of R.C.C. slabs
and beams.
93 13.10 Neat cement punning Sqm. 13763.8 30.00 4,12,913
94 13.14 Extra for providing and mixing water
proofing material in cement plaster work in
per bag
proportion recommended by the
of 50
manufacturers.
kg
4950.0 71.10 3,51,945
cement
used in
the mix
S.No S.O.R No.
Description Unit Qty Rate Amount

95 13.15 Extra for plastering exterior walls of height


more than 10 m from ground level for
sqm
every additional height of 3 m or part
thereof.
2nd Floor 7352.9 24.30 1,78,674
3rd Floor 7352.9 48.60 3,57,349
4th Floor 7352.9 72.90 5,36,023
5th Floor 7352.9 97.20 7,14,697
6th Floor 7352.9 121.50 8,93,371
7th Floor 7352.9 145.80 10,72,046
8th Floor 7352.9 170.10 12,50,720
9th Floor 7352.9 194.40 14,29,394
Mumty & parapet 5051.6 218.70 11,04,794
96 13.41 Providing and applying white cement based
putty of average thickness 1 mm, of
approved brand and manufacturer, Like
birla white /JK white or equivalent, over the
plastered wall surface to prepare the Sqm. 308936.0 66.60 2,05,75,135
surface even and smooth i/c all cost of
material, labour and scaffold etc in all
position complete.

97 13.49 Wall painting with plastic emulsion paint of


approved brand and manufacture to give
an even shade:
13.49.1 Two or more coats on new work Sqm. 309381.2 57.60 1,78,20,359
98 13.54 Finishing walls with textured exterior paint
of required shade :
13.54.1 New work (Two or more coats applied @
3.28 ltr/10 sqm) over and including priming
Sqm. 185.2 118.80 21,998
coat of exterior primer applied @
2.20kg/10 sqm.
99 13.55 Finishing walls with Acrylic Smooth exterior
paint of required shade:
13.55.1 New work (Two or more coat applied @
1.67 ltr/10 sqm over and including priming
Sqm. 3665.4 78.30 2,87,002
coat of exterior primer applied @ 2.20 kg/
10 sqm).
100 13.68 Painting with synthetic enamel paint of
approved brand and manufacture to give
an even shade :
13.68.1 Two or more coats on new work sqm 10311.8 47.70 4,91,874
S.No S.O.R No.
Description Unit Qty Rate Amount

101 16.2 Boring/drilling bore well of required dia


perfectly vertical to receive casing/ strainer
pipe, by suitable method prescribed in IS:
2800 (part I), including collecting samples
from different strata, preparing and
submitting strata chart/bore log, including
hire and running charges of all equipments,
tools, plants and machineries required for
the job, all complete as per direction of
Engineer –in-charge, beyond 90 metre
depth below ground level.

16.2.1 All types of soil


16.2.1.2 150 mm dia. meter 440.0 385.20 1,69,488
16.2.1.3 200 mm dia. meter 48.0 445.50 21,384
102 16.5 Supplying, assembling, lowering and fixing
in vertical position in bore well, ERW
(Electric Resistance Welded) FE 410 mild
steel screwed and socketed/ plain ended
casing pipes of required dia, conforming to
IS: 4270, of reputed and approved make,
including painted with outside surface
with two coats of anticorrosive paint of
approved brand and manufacture,
including required hire and labour
charges, fittings and accessories, all
complete, for all depths, as per direction of
Engineer- in-charge.

16.5.2 150 mm nominal size dia having


meter 220.0 1,071.90 2,35,818
minimum wall thickness 4.85 mm
16.5.3 200 mm nominal size dia having
meter 24.0 1,449.90 34,798
minimum wall thickness 5.40 mm
103 16.6 Supplying, assembling, lowering and fixing
in vertical position in bore well, ERW
(Electric Resistance Welded) FE 410 plain
slotted (having slot of size 1.6/3.2 mm) mild
steel threaded and socketed /plain bevel
ended pipe (type A) of required dia,
conforming to IS: 8110, of reputed and
approved make, having wall thickness not
less than 5.40 mm, including painted with
outside surface with two coats of
anticorrosive bitumestic paint of approved
brand and manufacture, including hire and
labour charges, fittings and accessories, all
complete, for all depths, as per direction of
Engineer –in-charge.
S.No S.O.R No.
Description Unit Qty Rate Amount

16.6.2 150 mm nominal size dia. meter 220.0 1,143.90 2,51,658


16.6.3 200 mm nominal size dia. meter 24.0 1,521.90 36,526
104 16.8 Development of tube well in accordance
with IS : 2800 (part I) and IS: 11189, to
establish maximum rate of usable water
yield without sand content (beyond
permissible limit), with required
capacity air compressor, running the
compressor for required time till well is
fully developed, measuring yield of well by
"V" notch method or any other approved
method, measuring static level and draw
hour 32.0 430.20 13,766
down etc. by step draw down method,
collecting water samples and getting
tested in approved laboratory, i/c
disinfection of tubewell, all complete,
including hire and labour charges of air
compressor, tools and accessories etc., all
as per requirement and direction of
Engineer-in-charge.

105 16.9 Providing and fixing suitable size threaded


mild steel cap or spot welded plate to the
top of bore well housing/ casing pipe,
removable as per requirement, all complete
for borewell of:

16.9.3 200 mm dia each 4.0 439.20 1,757


106 16.10 Providing and fixing M.S. clamp of required
dia made of 100 x10 mm flat to the top of
casing/ housing pipe of tubewell as per IS:
2800 (part I), including necessary bolts and
nuts of required size complete.

16.10.3 200 mm clamp. each 4.0 1,152.90 4,612


107 16.11 Providing and fixing Bail plug/ Bottom plug
of required dia to the bottom of pipe
assembly of tubewell as per IS:2800 (part I).

16.11.2 150 mm dia each 4.0 217.80 871


108 16.16 Supplying, filling, spreading and leveling
stone boulders of size range 5 cm to 20 cm,
in recharge pit, in the required thickness,
cum 40.0 684.00 27,360
for all leads and lifts, all complete as per
direction of Engineer-in-charge.
S.No S.O.R No.
Description Unit Qty Rate Amount

109 16.17 Supplying, filling, spreading and leveling


gravels of size range 5 mm to 10 mm, in the
recharge pit, over the existing layer of
boulders, in required thickness, for all leads cum 32.0 789.30 25,258
and lifts, all complete as per direction of
Engineer-in-charge.

110 16.18 Supplying, filling, spreading and leveling


coarse sand of size range 1.5 mm to 2 mm
in recharge pit, in required thickness over
cum 32.0 737.10 23,587
gravel layer, for all leads and lifts, all
complete as per direction of Engineer-in-
charge.
111 17.1 Providing and fixing water closet squatting
pan (Indian type W.C. pan) with 100mm
sand cast Iron P or S trap, uPVC P or S trap,
10 litre low level white P.V.C. flushing
cistern, including flush pipe, with manually
controlled device (handle lever) conforming
to IS : 7231, with all fittings and fixtures
complete including cutting and making
good the walls and floors wherever
required :

17.1.1 White Vitreous china Orissa pattern W.C.


pan of size 580x440mm with integral type each 168.0 2,695.50 4,52,844
foot rests.
112 17.3 Providing and fixing white vitreous china
pedestal type water closet (European type)
with seat and lid, 10 litre low level white
vitreous china flushing cistern and C.P.
flush bend with fittings and C.I.brackets,
40mm flush bend, overflow arrangement
with specials of standard make and
mosquito proof coupling of approved
municipal design complete including
painting of fittings and brackets, cutting
and making good the walls and floors
wherever required :

17.3.1 W.C. pan with ISI marked white solid plastic


Each 6.0 4,151.70 24,910
seat and lid.
S.No S.O.R No.
Description Unit Qty Rate Amount

113 17.5 Providing and fixing white vitreous china


extended wall mounting water closet of
size 780x370x690 mm of approved shape
including providing and fixing white
vitreous china cistern with dual flush fitting,
each 386.0 9,684.90 37,38,371
of flushing capacity 3 litre/6 litre
(adjustable to 4 litre/8 litres), including
seat cover, and cistern fittings, nuts, bolts
and gasket etc complete.

114 17.10 Providing and fixing white vitreous china


battery based infrared sensor operated
urinal of approx. size 610 x 390 x 370 mm
having pre and post flushing with water (
250 ml and 500 ml consumption), having
each 356.0 16,186.50 57,62,394
water inlet from back side, including fixing
to wall with suitable brackets all as per
manufacturers specification and direction
of Engineer-in-charge.

115 17.11 Providing and fixing wash basin with C.I.


brackets, 15 mm C.P. brass pillar taps,32
mm C.P. brass waste of standard pattern,
including painting of fittings and brackets,
cutting and making good the walls
wherever require :

17.11.5 White Vitreous China Angle back wash


basin size 600x480 mm with single 15 mm Each 6.0 1,597.50 9,585
C.P. brass pillar tap.
17.11.12 Oval shape wash basin over counter/under
counter with 15 mm C.P brass pillar tap
Each 479.0 7,153.20 34,26,383
(Counter to be paid sepratly)

116 17.14 Providing and fixing Stainless Steel A ISI 304


(18/8) kitchen sink as per IS 13983 with C.I.
brackets and stainless steel plug 40 mm
including painting of fittings and brackets,
cutting and making good the walls
wherever required :

17.14.2 Kitchen sink without drain board


17.14.2.1 610x510 mm bowl depth 200 mm. each 39.0 4,124.70 1,60,863
117 17.32 Providing and fixing soil, waste and vent
pipes :
17.32.1 CI Pipe (Sand Cast)
17.32.1.1 100 mm dia. Sand Cast Iron Socket & Spigot
(S&S) Pipe as Per IS. 1729. Wall Thickness meter 4599.0 791.00 36,37,809
5mm.
S.No S.O.R No.
Description Unit Qty Rate Amount

17.32.1.3 75 mm dia. Sand Cast Iron Socket & Spigot


(S&S) Pipe as Per IS. 1729. Wall Thickness meter 3950.0 645.00 25,47,750
5mm.
17.32.3 CI (Hubless)
17.32.3.1 100 mm dia. Hubless Centrifugally cast
(spun) iron Epoxy Coated Inside &
OutsideI/c Complete Coupling
Assembly(EPDM Rubber Gasket Stainless meter 1300.0 860.00 11,18,000
Steel Clamp & External Metallic/ Protective
Shield As per IS - 15905)Wall Thickness
3.5mm.
17.32.3.2 75 mm dia. Hubless Centrifugally cast
(spun) iron Epoxy Coated Inside &
OutsideI/c Complete Coupling
Assembly(EPDM Rubber Gasket Stainless meter 1935.0 723.00 13,99,005
Steel Clamp & External Metallic/ Protective
Shield As per IS - 15905)Wall Thickness
3.5mm.
118 17.34 Providing and fixing M.S. holder-bat
clamps of approved design to Sand Cast
iron/cast iron (spun) pipe embedded in and
including cement concrete blocks
10x10x10cm of Cement Concrete 1:2:4 mix
(1 cement : 2 sand : 4 graded stone
aggregate 20mm nominal size) including
cost of cutting holes and making good the
walls etc. :

17.34.1 For 100 mm dia. Pipe each 690.0 59.40 40,986


17.34.2 For 75 mm dia. Pipe each 665.0 33.30 22,145
Ground to top floor
119 17.35 Providing and fixing bend of required
degree with access door, insertion rubber
washer 3 mm thick, bolts and nuts
complete.
17.35.1 100 mm dia minimum wall thickness
6.5mm
17.35.1.2 Sand cast iron SandS as per IS - 3989 each 101.0 367.20 37,087
17.35.2 75 mm dia minimum wall thickness 6.5mm

17.35.2.2 Sand cast iron SandS as per IS- 3989 each 172.0 306.90 52,787
120 17.36 Providing and fixing plain bend of required
degree.
17.36.1 100 mm dia minimum wall thickness
6.5mm
17.36.1.1 Sand cast iron SandS as per IS - 1729 each 200.0 400.50 80,100
17.36.2 75 mm dia minimum wall thickness 6.5mm

17.36.2.2 Sand cast iron SandS as per IS - 3989 each 215.0 233.10 50,117
121 17.37 Providing and fixing heel rest sanitary bend
S.No S.O.R No.
Description Unit Qty Rate Amount

17.37.1 100 mm dia minimum wall thickness


6.5mm
17.37.1.2 Sand cast iron SandS as per IS - 3989 each 65.0 348.30 22,640
17.37.2 75 mm dia minimum wall thickness 6.5mm

17.37.2.2 Sand cast iron SandS as per IS - 3989 each 60.0 296.10 17,766
122 17.38 Providing and fixing double equal junction
of required degree with access door,
insertion rubber washer 3 mm thick, bolts
and nuts complete :
17.38.1 100x100x100x100mm minimum wall
thickness 6.5mm
17.38.1.2 Sand cast iron SandS as per IS - 3989 each 75.0 738.00 55,350
17.38.2 75x75x75x75 mm minimum wall thickness
6.5mm
17.38.2.2 Sand cast iron SandS as per IS - 3989 each 85.0 588.60 50,031
123 17.39 Providing and fixing double equal plain
junction of required degree.
17.39.1 100x100x100x100mm minimum wall
thickness 6.5mm
17.39.1.2 Sand cast iron SandS as per IS - 3989 each 75.0 703.80 52,785
17.39.2 75x75x75x75 mm minimum wall thickness
6.5mm
17.39.2.2 Sand cast iron SandS as per IS - 3989 each 80.0 515.70 41,256
124 17.40 Providing and fixing single equal junction of
required degree with access door, insertion
rubber washer 3 mm thick, bolts and nuts
complete.
17.40.1 100x100x100 mm minimum wall thickness
6.5mm
17.40.1.2 Sand cast iron SandS as per IS - 3989 each 60.0 576.00 34,560
17.40.2 75x75x75 mm minimum wall thickness
6.5mm
17.40.2.2 Sand cast iron SandS as per IS - 3989 each 65.0 479.70 31,181
125 17.41 Providing and fixing single equal plain
junction of required degree :
17.41.1 100x100x100 mm minimum wall thickness
6.5mm
17.41.1.2 Sand cast iron SandS as per IS - 3989 each 95.0 546.30 51,899
17.41.2 75x75x75 mm minimum wall thickness
6.5mm
17.41.2.2 Sand cast iron SandS as per IS - 3989 each 105.0 385.20 40,446
126 17.53 Providing and fixing terminal guard:
17.53.1 100 mm
17.53.1.2 Sand cast iron SandS as per IS - 3989 each 40.0 432.00 17,280
17.53.2 75 mm
17.53.2.2 Sand cast iron SandS as per IS - 3989 each 39.0 395.10 15,409
127 17.54 Providing and fixing collar:
17.54.1 100 mm
17.54.1.2 Sand cast iron SandS as per IS - 3989 each 680.0 285.30 1,94,004
17.54.2 75 mm
S.No S.O.R No.
Description Unit Qty Rate Amount

17.54.2.2 Sand cast iron SandS as per IS- 3989 each 655.0 197.10 1,29,101
128 17.55 Providing lead caulked joints to sand cast
iron/ centrifugally cast (spun) iron pipes
and fittings of diameter:
17.55.1 100 mm each 670.0 210.60 1,41,102
17.55.2 75 mm each 645.0 180.90 1,16,681
129 17.57 Providing and fixing trap of self cleansing
design with screwed down or hinged
grating with or without vent arm complete,
including cost of cutting and making good
the walls and floors :
17.57.1 100 mm inlet and 100 mm outlet
17.57.1.2 Sand Cast iron SandS as per IS: 1729. each 781.0 549.00 4,28,769
17.57.2 100 mm inlet and 75 mm outlet
17.57.2.2 Sand Cast iron SandS as per IS- 1729. each 1072.0 486.00 5,20,992
130 17.58 Providing and fixing unplasticised Rigid PVC
soil and waste pipes conforming to IS:
13592 Type B including jointing with seal
ring conforming to IS : 5382 leaving 10 mm
gap for thermal expansion. Single socketed
pipes for working pressure of 4 kg/sqcm.

17.58.1 75 mm diameter (minimum wall thickness


Meter 75.0 122.40 9,180
3.2mm)
17.58.2 110 mm diameter (minimum wall thickness
Meter 45.0 214.20 9,639
3.2mm)
131 17.59 Providing and fixing unplasticised PVC
moulded fittings/ accessories for
unplasticised Rigid PVC soil and waste pipes
conforming to IS: 13592 Type A including
jointing with seal ring conforming to IS :
5382 leaving 10 mm gap for thermal
expansion
17.59.1 Coupler
17.59.1.1 75 mm Each 29.0 105.30 3,054
17.59.1.2 110MM Each 18.0 138.60 2,495
17.59.4 Single tee without door
17.59.4.1 75x75x75 mm each 9.0 180.90 1,628
17.59.4.2 110x110x110 mm Each 6.0 239.40 1,436
17.59.5 Bend 87.50
17.59.5.1 75 mm bend Each 30.0 105.30 3,159
17.59.5.2 110 mm bend Each 12.0 154.80 1,858
132 17.60 Providing and fixing Unplasticised -PVC pipe
clips of approved design to Unplasticised -
PVC soil and waste pipes by means of
bombay nail of required length including
and making good the wall etc. complete.

17.60.2 110 mm Each 12.0 45.00 540


S.No S.O.R No.
Description Unit Qty Rate Amount

133 17.61 Providing and fixing uPVC trap of self


cleaning design complet. Including cost of
cutting and making good the wall and
floors.
17.61.1 100 mm inlet and 75 mm outlet Each 11.0 465.30 5,118
134 17.64 Providing and fixing P.V.C. waste pipe for
sink or wash basin including P.V.C. waste
fittings complete.
17.64.2 Flexible pipe
17.64.2.1 32 mm dia Each 877.0 78.30 68,669
17.64.2.2 40 mm dia. Each 59.0 88.20 5,204
135 17.68 Providing and fixing mirror of superior glass
(of approved quality) and of required shape
and size with plastic moulded frame of
approved make and shape with 6 mm thick
hard board backing :

17.68.1 Circular shape 450mm dia. Each 715.0 725.40 5,18,661


17.68.4 Rectangular Shape 1500x450mm Each 8.0 1,179.90 9,439
136 17.78 Providing and fixing C.P. brass grating of
approved quality and make conforming to
IS:specification.
17.78.1 100 mm dia. Each 1888.0 66.60 1,25,741
137 18.65 Providing and fixing PTMT bib cock of
approved quality and colour.
18.65.4 15mm nominal bore, 90mm long. Weighing
each 238.0 213.30 50,765
not less than 93 gms.
138 18.8 Providing and fixing Chlorinated Polyvinyl
Chloride (CPVC) pipes, having thermal
stability for hot and cold water supply
including all CPVC plain and brass threaded
fittings i/c fixing the pipe with clamps at
1.00 m spacing. This includes jointing of
pipes and fittings with one step CPVC
solvent cement and the cost of cutting
chases and making good the same including
testing of joints complete as per direction
of Engineer in Charge.

Concealed work including cutting chases


and making good the walls etc.,
18.8.1 15 mm nominal outer dia .Pipes. Meter 3012.8 186.30 5,61,285
18.8.2 20 mm nominal outer dia .Pipes. Meter 5439.9 210.60 11,45,643
18.8.3 25mm nominal outer dia .Pipes. Meter 428.4 259.20 1,11,041
18.8.4 32 mm nominal outer dia .Pipes. Meter 2059.2 324.00 6,67,181
139 18.10 Providing and fixing G.I. pipes complete
with G.I. fittings and clamps, including
cutting and making good the walls etc.
Internal work - Exposed on wall
S.No S.O.R No.
Description Unit Qty Rate Amount

18.10.3 25 mm nominal outer dia .Pipes. metre 80.0 270.00 21,600


18.10.4 32 mm nominal outer dia .Pipes. Meter 893.2 324.90 2,90,201
18.10.6 50 mm dia. nominal bore Meter 5439.2 536.40 29,17,587
140 18.11 Providing and fixing G.I. pipes complete
with G.I. fittings and clamps including
cutting and making good the walls etc.
concealed pipe including painting with anti
corrosive bitumastic paint, cutting chases
and making good the wall.

18.11.2 20 mm dia nominal bore metre 25.0 278.10 6,953


141 18.12 Providing and fixing G.I. pipes complete
with G.I. fittings including trenching and
refilling etc.External work :

18.12.6 50 mm dia. nominal bore metre 410.0 442.80 1,81,548


18.12.7 65 mm dia. nominal bore metre 325.0 479.70 1,55,903
18.12.8 80 mm dia. nominal bore metre 160.0 559.80 89,568
142 18.32 Providing and fixing gun metal gate valve
with C.I. wheel of approved quality
(screwed end) :
18.32.4 50 mm nominal bore each 55.0 878.40 48,312
18.32.5 65 mm nominal bore each 95.0 1,205.10 1,14,485
18.32.6 80 mm nominal bore each 30.0 2,017.80 60,534
143 18.34 Providing and fixing CPVC gate valve with
knob of approved quality.
18.34.1 25 mm nominal bore. Each 8.0 385.20 3,082
18.34.2 32 mm nominal bore. Each 95.0 450.00 42,750
18.34.4 50 mm nominal bore Each 95.0 674.10 64,040
144 18.38 Providing and fixing uplasticised PVC
connection pipe with brass unions :
18.38.1 30 cm length
18.38.1.2 20 mm nominal bore Each 14.0 116.10 1,625
145 18.40 Constructing masonry Chamber 60x60x75
cm inside, in brick work in cement mortar
1:4 (1 cement : 4 sand) for sluice valve, with
C.I. surface box 100mm. top diameter, 160
mm bottom diameter and 180 mm deep (
inside) with chained lid and RCC top slab
1:2:4 mix (1 cement :2 sand : 4 graded
stone aggregate 20mm nominal size ) , i/c
necessary excavation, foundation concrete
1:5:10 (1 cement : 5 sand : 10 graded stone
aggregate 40 mm nominal size) and inside
plastering with cement mortar 1:3 (1
cement : 3 sand) 12 mm thick finished with
a floating coat of neat cement complete as
per standard design :
S.No S.O.R No.
Description Unit Qty Rate Amount

18.40.1 With common burnt clay bricks of 25 kg


each 30.0 4,874.40 1,46,232
/sqcm compressive strength.
146 18.45 Painting G.I. pipes and fittings with two
coats of anti-corrosive bitumastic paint of
approved quality :
18.45.6 50 mm diameter pipe metre 410.0 9.00 3,690
18.45.7 65 mm diameter pipe metre 325.0 11.70 3,803
18.45.8 80 mm diameter pipe metre 160.0 13.50 2,160
147 18.47 Providing and fixing G.I. Union in G.I. pipe
including cutting and threading the pipe
and making long screws etc. complete (New
work)
18.47.6 50mm nominal bore each 136.0 385.20 52,387
18.47.7 65mm nominal bore each 1803.0 562.50 10,14,188
18.47.8 80 mm nominal bore each 53.0 646.20 34,249
148 18.49 Providing and placing on terrace (at all floor
levels) polyethylene water storage tank ISI :
12701 marked with cover and suitable
locking arrangement and making necessary per
4000.0 6.30 25,200
holes for inlet, outlet and overflow pipes litre
but without fittings and the base support
for tank

149 18.54 Providing and fixing C.P. brass long body


bib cock of approved quality conforming to
IS standards and weighing not less than
690 gms.
18.54.1 15 mm nominal bore each 222.0 489.60 1,08,691
150 18.56 Providing and fixing C.P. brass angle valve
for basin mixer and geyser points of
approved quality conforming to IS:8931

18.56.1 15 mm nominal bore each 14.0 464.40 6,502


151 18.64 Providing and fixing C.P. brass shower rose
with 15 or 20 mm inlet :
18.64.2 150 mm diameter each 3.0 477.00 1,431
152 18.82 Providing and fixing CP jet assembly to
Each 460.0 337.50 1,55,250
including connection etc complete.
153 19.20 Supplying and fixing C.I. cover without
frame for manholes :
19.20.1 455x610 mm rectangular C.I. cover (light
duty) the weight of the cover to be not less each 11.0 1,293.30 14,226
than 23 kg.
S.No S.O.R No.
Description Unit Qty Rate Amount

154 19.4 Providing and laying below ground


unplasticised PVC pipe to with stand
working pressure of 4 kg/cm2 soild waste
pipes confirming to IS:13592 and IS:4985
including jointing with seal ring confirming
to IS :5282 leaving 10mm gap for thermal
expansion all necessary fittings etc.
complete. Excavation to be paid seperataly.

19.4.1 110 mm diameter OD RM. 40.0 210.60 8,424


155 19.5 Providing and laying cement concrete 1:3:6
(1 cement : 3 sand : 6 graded stone
aggregate 20 mm nominal size) all-round
PVC. pipes including bed concrete as per
standard design:
19.5.1 110 mm diameter PVC. pipe RM. 40.0 518.40 20,736
156 19.7 Providing and fixing square-mouth S.W.
gully trap class SP1 complete with C.I.
grating brick masonry chamber with water
tight C.I. cover with frame of 300 x300 mm
size (inside) the weight of cover to be not
less than 4.50 kg and frame to be not less
than 2.70 kg as per standard design :

19.7.3 180x150 mm size P type


19.7.3.1 With well burnt bricks Each 37.0 1,721.70 63,703
157 19.8 Providing and laying non-pressure NP2 class
(light duty) R.C.C. pipes with collars jointed
with stiff mixture of cement mortar in the
proportion of 1:2 (1 cement : 2 sand)
including testing of joints etc. complete :

19.8.2 150 mm dia. R.C.C. pipe metre 210.0 256.50 53,865


19.8.3 250 mm dia. R.C.C. pipe metre 200.0 346.50 69,300
19.8.4 300 mm dia. R.C.C. pipe metre 1098.0 432.00 4,74,336
19.8.7 600 mm dia. R.C.C. pipe metre 298.0 1,150.20 3,42,760
S.No S.O.R No.
Description Unit Qty Rate Amount

157 19.9 Constructing brick masonry manhole in


cement mortar 1:4 ( 1 cement : 4 sand )
R.C.C. top slab with Cement Concrete 1:2:4
mix (1 cement : 2 sand : 4 graded stone
aggregate 20 mm nominal size), foundation
concrete 1:4:8 mix (1 cement : 4 sand : 8
graded stone aggregate 40mm nominal
size) inside plastering 12mm thick with
cement mortar 1:3 (1 cement : 3 sand)
finished with floating coat of neat cement
and making channels in cement concrete
1:2:4 (1 cement : 2 sand : 4 graded stone
aggregate 20mm nominal size) finished
with a floating coat of neat cement
complete as per standard design :

158 19.9.1 Inside size 90x80 cm and 45 cm deep


including C.I. cover with frame (light duty)
455x610 mm internal dimensions total
weight of cover and frame to be not less
than 38 kg (weight of cover 23 kg and
weight of frame 15 kg) :
19.9.1.1 With well burnt bricks Each 37.0 7,197.30 2,66,300
19.9.2 Inside size 120x90 cm and 90 cm deep
including C.I. cover with frame (medium
duty) 500 mm internal diameter, total
weight of cover and frame to be not less
than 116 kg (weight of cover 58 kg and
weight of frame 58 kg) :

19.9.2.1 With well burnt bricks each 40.0 16,277.40 6,51,096


159 19.10 Extra for depth for manholes
19.10.1 Size 90x80 cm
19.10.1.1 With well burnt bricks metre 40.0 5,558.40 2,22,336
19.10.2 Size 120x90 cm
19.10.2.1 With well burnt bricks metre 40.0 6,642.00 2,65,680
S.No S.O.R No.
Description Unit Qty Rate Amount

160 19.11 Constructing brick masonry circular type


manhole 0.91m internal dia at bottom and
0.56m dia at top in cement mortar 1:4 (1
cement : 4 sand), inside cement plaster 12
mm thick with cement mortar 1:3 (1
cement : 3 sand) finished with a floating
coat of neat cement, foundation concrete
1:3:6 mix (1 cement : 3 sand : 6 graded
stone aggregate 40mm nominal size), and
making necessary channel in cement
concrete 1:2:4 (1 cement : 2 sand : 4 graded
stone aggregate 20mm nominal size)
finished with a floating coat of neat cement
all complete as per standard design :

19.11.1 0.91 m deep with S.F.R.C. cover and frame


(heavy duty, HD-20 grade designation)
560mm internal diameter conforming to
I.S. 12592, total weight of cover and frame
to be not less than 182kg., fixed in cement
concrete 1:2:4 (1 cement : 2 sand : 4
graded stone aggregate 20 mm nominal
size) including centering shuttering all
complete. (Foot rests and 12mm thick
cement plaster at the external surface shall
be paid for separately) :

19.11.1.1 With well burnt bricks each 10.0 7,576.20 75,762


161 19.12 Extra depth for circular type manhole
0.91m internal dia (at bottom) beyond
0.91m to 1.67m
19.12.1 With well burnt bricks metre 10.0 4,713.30 47,133
162 19.13 Constructing brick masonry circular
manhole 1.22m internal dia at bottom and
0.56m dia at top in cement mortar 1:4 (1
cement :4 sand) inside cement plaster
12mm thick with cement mortar 1:3 (1
cement :3 sand) finished with a floating
coat of neat cement foundation concrete
1:3:6 (1 cement : 3 sand : 6 graded stone
aggregate 40mm nominal size) and making
necessary channel in cement concrete 1:2:4
(1 cement : 2 sand : 4 graded stone
aggregate 20mm nominal size) finished
with a floating coat of neat cement all
complete as per standard design :
S.No S.O.R No.
Description Unit Qty Rate Amount

19.13.1 1.68 m deep with SFRC Cover and frame


(heavy duty HD-20 grade designation)
560mm internal diameter conforming to
I.S. 12592, total weight of cover and frame
to be not less than 182kg. fixed in cement
concrete 1:2:4 (1 cement : 2 sand : 4 graded
stone aggregate 20mm nominal size)
including centering shuttering all complete.
(Foot rests and 12 mm thick cement plaster
at the external surface shall be paid for
separately) :

19.13.1.1 With well burnt bricks each 15.0 14,323.50 2,14,853


163 19.14 Extra depth for circular type manhole
1.22m internal dia (at bottom) beyond 1.68
m to 2.29 m :
19.14.1 With well burnt bricks metre 15.0 6,128.10 91,922
164 19.36 Providing & Fixing of Precast RCC drain
cover of size 600x450 x70mm (thickness)
with 4 holes, manufactured by using M-30
grade of concrete reinforced with 8mm dia
Tor Steel @100mm c/c both ways,
manufactured by vibro compaction process
using joint less FRP moulds, so at to achieve
Each 1041.0 315.00 3,27,915
shuttering finish on five faces @top face
will have broom finish etc complete.

165 19.37 Providing & Fixing of Precast RCC drain


cover of size 750x600 x70mm (thickness)
with 6 holes, manufactured by using M-30
grade of concrete reinforced with 8mm dia
Tor Steel @100mm c/c both ways,
manufactured by vibro compaction process
using joint less FRP moulds, so at to achieve
Each 1009.0 495.00 4,99,455
shuttering finish on five faces @top face
will have broom finish etc complete.
S.No S.O.R No.
Description Unit Qty Rate Amount

166 19.38 Providing & Fixing of Precast RCC drain


cover of size 900x450 x90mm (thickness)
with 8 holes, manufactured by using M-30
grade of concrete reinforced with two
layers of 8mm dia Tor Steel @100mm c/c
both ways, manufactured by vibro
compaction process using joint less FRP
Each 2689.0 810.00 21,78,090
moulds, so at to achieve shuttering finish
on five faces @top face will have broom
finish etc complete.

167 19.39 Providing & Fixing of Precast RCC drain


cover of size 1150x400 x100mm (thickness)
with 10 holes, manufactured by using M-30
grade of concrete reinforced with two
layers of 8mm dia Tor Steel @100mm c/c
both ways, manufactured by vibro
compaction process using joint less FRP
moulds, so at to achieve shuttering finish Each 3025.0 990.00 29,94,750
on five faces @top face will have broom
finish etc complete.

168 21.3 Providing and fixing glazing in aluminium


door, window, ventilator shutters and
partitions etc. with EPDM rubber/
neoprene gasket etc. complete as per the
architectural drawings and the directions of
engineer-in-charge . (Cost of aluminium
snap beading shall be paid in basic item) :

21.3.2 With float glass panes of 5.5 mm thickness


sqm 50.9 838.80 42,726
21.3.3 With float glass panes of 8 mm thickness
sqm 3024.0 1,162.80 35,16,307
S.No S.O.R No.
Description Unit Qty Rate Amount

169 22.1 Providing and laying integral cement based


treatment for water proofing on horizontal
surface at all depth below ground level for
under ground structures as directed by
Engineer-in-Charge consisting of :
a) Ist layer of 22mm to 25mm thick
approved and specified rough stone slab
over a 25mm thick base of cement mortar
1:3 (1 cement : 3 sand) mixed with water
proofing compound conforming to IS:2645
in the recommended proportion over the
levelling course (levelling course to be paid
separately). Joints sealed and grouted with
cement slurry mixed with water proofing
compound .
b) 2nd layer of 25mm thick cement mortar
1:3 (1 cement : 3 sand) mixed with water
proofing compound in recommended
proportions.
c) Finishing top with stone aggregate of
10mm to 12mm nominal size spreading @
8 cudm/sqm thoroughly embedded in the
2nd layer. (with 5 years service guarantee)

22.1.1 Using rough Kota stone. sqm 14213.4 824.40 1,17,17,486


170 22.2 Providing and laying integral cement based
treatment for water proofing on the
vertical surface by fixing specified stone
slab 22 mm to 25mm thick with cement
slurry mixed with water proofing
compound conforming to IS:2645 in
recommended proportions with a gap of
20mm (minimum) between stone slabs and
the receiving surfaces and filling the gaps
with neat cement slurry mixed with water
proofing compound and finishing the
exterior of stone slab with cement mortar
1:3 (1 cement : 3 sand) 20mm thick with
neat cement punning mixed with water
proofing compound in recommended
proportion complete at all levels and as
directed by Engineer-in-charge : (with 5
years service guarantee)

22.2.1 Using rough Kota stone. sqm 3233.5 911.70 29,48,000


S.No S.O.R No.
Description Unit Qty Rate Amount

171 22.3 Providing and laying water proofing


treatment to vertical and horizontal
surfaces of depressed portions of W.C.,
kitchen and the like consisting of :

a) Ist course of applying cement slurry @


4.4 Kg/sqm mixed with water proofing
compound conforming to IS 2645 in
recommended proportions including
rounding off junction of vertical and
horizontal surface.
b) IInd course of 20mm cement plaster 1:3
(1 cement : 3 sand) mixed with water
proofing compound in recommended
proportion including rounding off junction
of vertical and horizontal surface.

c) IIIrd course of applying blown or residual


bitumen applied hot at 1.7 Kg. per sqm of
area.
d) IVth course of 400 micron thick PVC
sheet. (Overlaps at joints of PVC sheet
should be 100 mm wide and pasted to each
Sqm. 5354.7 396.00 21,20,469
other with bitumen @ 1.7 Kg/sqm.) (with 5
years service guarantee)

172 22.6 Providing and laying water proofing


treatment on roofs of slabs by applying
cement slurry mixed with water proofing
cement compound consisting of applying :
a) after surface preparation, first layer of
slurry of cement @ 0.488 kg/sqm mixed
with water proofing cement compound @
0.253 kg/sqm.b) laying second layer of
Fibre glass cloth when the first layer is still
green. Overlaps of joints of fibre cloth
should not be less than 10 cm.c) third layer
Sqm. 16105.2 304.20 48,99,203
of 1.5 mm thickness consisting of slurry of
cement @ 1.289 kg/sqm mixed with water
proofing cement compound @ 0.670
kg/sqm and sand @ 1.289 kg/sqm. This will
be allowed to air cure for 4 hours followed
by water curing for 48 hours. The entire
treatment will be taken upto 30cm on
parapet wall and tucked into groove in
parapet all around.

173 22.14 Grading roof for water proofing treatment


with
S.No S.O.R No.
Description Unit Qty Rate Amount

22.14.1 Cement concrete 1:2:4 (1 cement : 2 sand :


4 graded stone aggregate 20 mm nominal cum 805.3 4,112.10 33,11,273
size)
174 23.1 Trenching in ordinary soil up to a depth of
60cm including removal and stacking of
serviceable materials and then disposing of
surplus soil, by spreading and neatly
leveling within a lead of 50m and making
up the trenched area to proper levels by cum 10342.0 186.30 19,26,715
filling with earth or earth mixed with sludge
or/and manure before and after flooding
trench with water (excluding cost of
imported earth, sludge or manure).

175 23.2 Supplying and stacking of good earth at site


including royalty if any and carriage (earth
cum 2585.5 511.20 13,21,708
measured in stacks will be reduced by 20%
for payment).
176 23.3 Supplying and stacking sludge at site
including royalty and carriage (sludge
cum 2585.5 643.50 16,63,769
measured in stacks will be reduced by 8%
for payment).
177 23.4 Supplying and stacking at site dump
manure from approved source, including
carriage (manure measured in stacks will cum 2585.5 734.40 18,98,791
be reduced by 8% for payment) :

178 23.8 Spreading of sludge, dump manure and / or


good earth in required thickness as per
direction of Officer-in-charge (Cost of
cum 7756.5 16.20 1,25,655
sludge, dump manure and / or good earth
to be paid separately).

179 23.9 Mixing earth and sludge or manure in the


required proportion specified or directed cum 7756.5 10.80 83,770
by the Officer-in-charge.
180 23.10 Grassing with selected type of grass
including watering and maintenance of the
lawn for 30 days or more till the grass
forms a thick lawn, free from weeds and fit
for mowing including supplying good earth,
if needed (the good earth shall be paid for
separately):

23.10.1 In rows 15 cm apart in either direction. 100


64.6 1,163.70 75,219
sqm
23.10.2 In rows 7.5 cm apart in either direction 100
64.6 2,404.80 1,55,440
sqm
23.10.3 In rows 5 cm apart in both directions. 100
64.6 3,601.80 2,32,811
sqm
S.No S.O.R No.
Description Unit Qty Rate Amount

23.10.4 With grass Turf. 100


64.6 2,856.60 1,84,643
sqm
181 23.14 Digging holes in ordinary soil and refilling
the same with the excavated earth mixed
with manure or sludge in the ratio of 2:1 by
volume (2 parts of stacked volume of earth
after reduction by 20% : 1 part of stacked
volume of manure after reduction by 8%)
flooding with water, dressing including
removal of rubbish and surplus earth, if any
with all leads and lifts (cost of manure,
sludge or extra good earth if needed to be
paid for separately) :

23.14.1 Holes 1.2 m dia and 1.2 m deep. each 1200.0 141.30 1,69,560
23.14.2 Holes 60 cm dia, and 60 cm deep. each 1000.0 61.20 61,200
23.14.3 Holes 45 cm dia, and 45 cm deep. each 1000.0 18.90 18,900
23.14.4 Holes 30 cm dia, and 30 cm deep. each 3000.0 9.00 27,000
182 23.15 Providing and planting different variety of
plants of approved quality and sizes as
mentioned including making pits of
required size at site, refilled with B.C. Soil
mixture mannuring and pesticide etc.
complete (to be paid separately) including
watering and 90 days maintenance from
the date of final bill as per direction of
engineer in charge complete in all respect
(B.C. Mixture paid separately).

23.15.1 Any of one from Plameriya alba, fycus


Benjameena, Malkikeya champa, Begnonia
each 2000.0 580.50 11,61,000
plumaric pudoca Plants (1.80mtrs to
2.10mtrs height.
23.15.2 Any of one from Lantana VAR Red, Lantana
Blue White, Hemelia Mini, Lantana
varicated, Ticoma Redicens, Spi Oala, each 2000.0 29.70 59,400
Golden Dunanta.(height 0.3 m to 0.45 m)

23.15.3 Any of one from Hibiscus Vice Rai, Gul


Phinia, Bamboo Varicated, Chandani
Vericated, Hamilia Pattern, Bouganvellia,
each 500.0 48.60 24,300
Canna Red/Yellow, Taqwamonasia. (height
0.3 m to 0.45 m)

23.15.4 Any of one from Spathodia, Silver Oak,


Thuja, Golden Bottle Brush, Exora Red. each 500.0 287.10 1,43,550
(height 0.45 m to 0.60 m)
S.No S.O.R No.
Description Unit Qty Rate Amount

23.15.5 Any of one from Glerodendron, Allamamala


New, Allamanda Bail, Thima Bouganvellia. each 200.0 86.40 17,280

23.15.6 Any of one from Climetics, Venentora.


each 200.0 65.70 13,140
(height 0.3 m to 0.45 m)
23.15.7 Foxtail Palm (1.80mtrs to 2.10mtrs height.)
each 200.0 1,605.60 3,21,120
23.15.8 Cycus (1.80mtrs to 2.10mtrs height.) each 200.0 2,760.30 5,52,060
23.15.9 Ficus Varicated (1.80mtrs to 2.10mtrs
each 200.0 894.60 1,78,920
height.)
23.15.10 Casia Biflora (0.45mtrs to 0.60 mtrs height.)
each 200.0 116.10 23,220
183 23.21 Supplying and stacking of well decayed
cow dung manure at site including
royalty and carriage upto 1 km (Cow dung
cum 2585.5 717.30 18,54,579
manure measured in stacks will reduced by
8% for Payment).

184 23.23 Providing and fixing M. S. tree guard 50 cm


square in plan, height 1.40 metre above
ground level and 0.50 metre below
ground level. The vertical members shall
consist of four nos. of angle iron of size
25x25x5 mm 1.9 long, one at each corner
and 8 nos. flat iron of size 25x5 mm 1.4
long. The vertical members shall be welded
to 4 nos. 25x6 mm M. S. flats placed
horizontally around the vertical member of
the cage. One name plate of 1 mm thick
M.S. sheet of size 250x100 mm shall be
welded to the tree guard near the middle each 3000.0 2,244.60 67,33,800
height and lettered PWD/ any other
approved name. The tree guard shall be
fixed to the ground by making suitable
holes and by embedding four corners leg in
the ground , including refilling the earth,
compaction etc. complete. The tree guard
shall be painted with two coats of paint of
approved brand and manufacture over a
coat of primer, complete in all respect.
S.No S.O.R No.
Description Unit Qty Rate Amount

185 25.3 Providing and fixing white vitreous china


extended Wall Mounted Anti germ Fluoro-
Polymer Coated water closet Size 350 X
360 X 545mm of approved shape (Wall
Hung W. C. pan size 350 X 360 X 545mm)
with soft closing seat cover, and 7.2 litre
Low level slim dual flushing, PP (Poly
Propeline) made 80 mm thick consealed
flushing cistern, flushing capcity 3 litre/6
litre, with all fittings and fixures complete
including cutting and making good the wall
and floors wherever required :

25.3.1 Anti germ Fluoro-Polymer Coated (neno


coating) Wall hung water closet Size 350 X
each 231.0 18,936.00 43,74,216
360 X 545mm with solid poly propelyne
made soft closing seat cover
186 25.7 Providing and fixing white vitreous china
type Anti germ Fluoro-Polymer Coated
Wash Basin size 160x580x450mm with C.I.
Brakets, 15 mm C. P. wall mounted
pressmatic pillar cock auto closing system
(decol technology), 15mm quarter turn
angular stop cock, 32 mm C.P. brass
made waste coupling length 130mm and 32
mm C.P. Brass Made Bottle Trap size
200x300mm fittings and fixures complete
including Painting of fittings and cutting
and making good the wall and floors
wherever required :

25.7.1 White Vetrious China Anti germ Fluoro-


Polymer Coated Wash Basin Size
160x580x450 mm with basin mounted each 231.0 12,168.00 28,10,808
pressmatic pillar cock auto closing system
(decol technology).
187 25.19 Providing and fixing in position best indian (
bonut size 24mm, ceramic disc size 19mm
and min. body thickness 2mm, nickel
each 602.0 1,512.00 9,10,224
plating 0.10 micron and chrome plating 0.3
micron, quarter turn) two wayBib cock.

188 25.39 Providing and fixing in position best indian


Auto Closing Bib Cock (with DECOL each 231.0 2,160.00 4,98,960
cartredge) for comon area use.
189 25.53 Providing and fixing in position best indian
C. P. Brass made (0.3 micron Chrom and 10
each 231.0 1,728.00 3,99,168
micron Nickel plated) Single Towel Ring
Square .
S.No S.O.R No.
Description Unit Qty Rate Amount

190 25.55 Providing and fixing in position best indian


C. P. Brass made (0.3 micron Chrom and 10
each 373.0 2,646.00 9,86,958
micron Nickel plated) Soap Dispenser with
Metallic Bottle .
191 25.58 Providing and fixing in position best indian
C. P. Brass made (0.3 micron Chrom and 10
each 470.0 1,026.00 4,82,220
micron Nickel plated) Toilet Roll Holder .

192 25.59 Providing and fixing in position best indian


C. P. Brass made (0.3 micron Chrom and 10
micron Nickel plated) Glass Self size each 333.0 1,188.00 3,95,604
600mm with toughened glass

Fire Fighting
193 26.1 Providing laying, testing and commissioning
of 'C' class heavy duty MS pipe confirming
to IS 1239/3589 i/c fittings like elbows,
tees, flanges, tapers, nuts bolts, gaskets etc.
in ground including excavation and
providing cement concrete blocks as
supports, at prescrived intervals and
anticorrosive treatment with
coaltar/asphalt tape as per IS 10221, with
4mm thick fiber reinforced tape and l2rnn1
overlap and refilling the trench etc. ofthe
following sizes complete as directed by
Engineer-in-Charge.

26.1.1 200mm dia metre 20.0 2,817.00 56,340


26.1.2 150mm dia metre 1150.0 1,927.00 22,16,050
26.1.3 80mm dia metre 50.0 933.00 46,650
194 26.3 Providing laying, testing and commissioning
of class 'C' heavy duty MS pipe confirming
to IS 3589/1239 including fittings like
elbows, tees, flanges, tapers, nuts bolts, 0.0
gasket etc. fixing the pipe on the
wall/ceiling with suitable clamps and
painting with
26.3.1 200mm dia metre 50.0 2,806.00 1,40,300
26.3.2 150mm dia metre 3765.0 1,916.00 72,13,740
26.3.3 100mm dia metre 6080.0 1,328.00 80,74,240
26.3.4 80mm dia metre 7265.0 921.00 66,91,065
26.3.5 65mm dia metre 8715.0 743.00 64,75,245
26.3.6 50mm dia metre 8500.0 588.00 49,98,000
26.3.7 40mm dia metre 9500.0 443.00 42,08,500
26.3.8 32mm dia metre 10500.0 391.00 41,05,500
26.3.9 25mm dia metre 13750.0 310.00 42,62,500
S.No S.O.R No.
Description Unit Qty Rate Amount

195 26.4 Supplying and fixing single headed internal


hydrant valve with instaneous Gun metal
couplings of 63mm dia with cast iron wheel
each 121.0 8,445.00 10,21,845
ISI marked conforming to IS 5290 (Type -A)
with blank gunmetal cap and chain as
required.
196 26.5 Supplying and fixing single headed external
yard hydrant valve with 1 no. 63mm dia
instaneous FM Gun metal coupling and cast
iron wheel, ISI marked confirming to IS each 30.0 8,445.00 2,53,350
5290 (Type -A) with blank gunmetal cap
and chain as required.

197 26.6 Supplying, fixing, testing and


commissioning of butterfly valve PN 1.6,
with Bronze/Gunmetal seat duly ISI marked
0.0
complete with Nuts, Bolts, washers,
gaskets, confirming to IS 13095, of
following sizes as required.
26.6.1 200 mm dia each 10.0 9,043.00 90,430
26.6.2 150 mm dia each 80.0 4,516.00 3,61,280
26.6.3 80 mm dia each 75.0 2,511.00 1,88,325
198 26.7 Supplying and fixing orifice plate made of
6mm thick stainless steel with orifice of
required size in between flanged and
landing valve of external and internal
each 121.0 1,196.00 1,44,716
hydrant to reduce pressure to working
pressure of 3.5 kg/cm complete as per
specification as r

199 26.8 Providing, installation, testing and


commissioning of dual plate non-return
valve of following sizes confirming to IS
0.0
5312 complete with rubber gasket, GI bolts,
nuts, washers etc. as required.

26.8.1 200 mm dia each 15.0 18,239.00 2,73,585


26.8.2 100 mm dia each 15.0 7,000.00 1,05,000
26.8.3 80 mm dia each 15.0 5,286.00 79,290
200 26.10 Providing, installation, testing and
commissioning of gun metal valves of 0.0
following sizes as required.
26.10.1 50 mm dia each 50.0 2,534.00 1,26,700
26.10.2 25 mm dia each 50.0 1,041.00 52,050
201 26.11 Supplying and fixing 63mm dia, 15 mtr long
RRL hose pipe with 63mm dia male and
female gun metal couplings duly binded
each 121.0 7,077.00 8,56,317
with GI wire, rivets etc. confirming to IS 636
(type-A)as required.
S.No S.O.R No.
Description Unit Qty Rate Amount

202 26.12 Supplying and fixing first -Aid hose reel


with MS construction spray painted in post
office red, confirming to IS 884 with upto
each 242.0 6,064.00 14,67,488
date amendments, complete with the
following as required.

a) 20/30/40m long 20mm (nominal


internal) dia water hose thermoplastic
0.0
(textile reinfirced ) type -2 as per IS 12585

b) 20mm (nominal internal) dia gun metal


0.0
globe valve and nozzle.
c) Drum and brakets for fixing the
0.0
equipments on wall.
d) Connections from riser with 40 mm dia
stop valve (gun metal ) and M.S. pipe 0.0

203 26.13 Supplying and fixing hose cabinet of size


900mmx600mmx500mm made of 2 mm
thick MS sheet with 6 mm thick glazed glass
doors i/c necessary locking arrangement each 30.0 16,173.00 4,85,190
suitable to accommodate external hydrant
with butterfly valve 2 nos. 15mtr. Long
hose pipe, 1 no
204 26.14 Supplying and fixing 63mm gun metal
branch pipe with 20 mm (nominal internal
diameter) size gun metal nozzle conforming
to IS 903, suitable for instaneous each 121.0 2,509.00 3,03,589
connection to interconnect hose pipe
coupling as required.

205 26.15 Supplying and fixing 4 way fire brigade


connection of cast iron body with 4 nos.
gun metal male instantaneous inlet
couplings complete with cap and chain as
each 8.0 14,169.00 1,13,352
required. For 150mm dia MS pipe
connection, confirming to IS 904 as
required.

206 26.16 Supplying and fixing 2 way FBC of CI body


with 2 nos. gun metal male instantaneous
inlet couplings complete with cap and chain
as required. For 150mm dia MS pipe each 2.0 9,485.00 18,970
connection, confirming to IS 904 as
required.
S.No S.O.R No.
Description Unit Qty Rate Amount

207 26.17 Supplying and fixing air vessel made of


250 mm dia, 8mm thick MS sheet, 1200
mm. in height with air release valve on top
and flanged connection to riser, drain each 2.0 11,744.67 23,489
arrangement with 25mm dia gun metal
wheel valve, with required accessories,
pressure gauge a
208 26.18 Providing fixing testing and commissioning
of 15 mm size quartzoid bulb type
sprinklers, of rating 68 degree C. pendent each 7400.0 515.00 38,11,000
with required accessories.

209 26.19 Providing and fixing Pressure switch in the


MS pipe Line including connection etc. as each 140.0 1,487.00 2,08,180
required.
210 26.20 Providing and fixing flow switches in
each 121.0 3,526.00 4,26,646
100/150mm dia MS pipe.
211 26.22 Providing and fixing angle iron
(40mmx40mm x5mm) door frame and MS
sheet (2mm thick) cum glass shutter of size
2.1 mtr. X 1.2mtr. (N.S.) with
each 121.0 7,045.00 8,52,445
25mmx25mmx3mm angle frame all around
and stiffened in between i/c hinges, handle,
locking arrangement, painting wit

212 26.23 Providing and fixing of carbon-di-oxide type


fire extinguishers consisting of welded M.S.
cylindrical body, squeeze lever discharge
valve fitted with pressure indicating guage 0.0
internal discharge tube 30 cms long high
pressure discharge hose, discharge no

26.23.1 Capacity 4.5 Kg. each 300.0 11,351.00 34,05,300


213 26.24 Providing and fixing of ABC Powder type
fire extinguishers consisting of welded M.S.
cylinderical body, squeeze lever discharge
valve fitted with pressure indicating guage
0.0
internal discharge tube 30 cms long high
pressure discharge hose, discharge nozzle

26.24.1 Capacity 5.0 Kg. each 300.0 7,301.00 21,90,300

Sinage
S.No S.O.R No.
Description Unit Qty Rate Amount

214 27.9 Providing and fixing Stainless steel plate


304grade of 1.50mm thick, including
writing with Embossing of letters of
required size including fixing at required
placed with studs, screws and rawl plugs
etc. compete as per direction of engineer-in- Sqm 184.5 12,286.80 22,67,283
charge.

215 27.10 Providing and fixing of name plate for


offices name of Stainless steel plate 304
grade of 1.50mm thick, including writing
with computerized vinayle sheet letters of
required size including fixing at required
placed with studs, screws and rawl plugs
Sqm 50.2 10,733.40 5,38,602
etc. compete as per direction of engineer
incharge.

216 27.11 Providing and fixing Aluminum composite


panels Silver colour with matte finish, 3mm
thick, (0.25mm 2.5mm and 0.25mm) sheet
for name plate including writing with
computerized vinayle sheet letters of
required size including fixing at required
placed with 1.25m Chromium plated Steel
Sqm 53.5 6,558.30 3,50,869
Pipe 15mm dia, compete as per direction of
engineer-in-charge.
S.No S.O.R No.
Description Unit Qty Rate Amount

217 27.13 Providing and fixing stainless steel English


(Capital) and Hindi letters in standard
pattern bellow type made with 1.20 mm
thick stainless steel (ASI Grade-304) Jindal
or equivalent. Depth of letter shall not be
less than 30mm and rate includes
Per
welding/soldering of joints polishing,
letter
buffing and fixing on the wall beam surface 3825.0 67.50 2,58,188
per cm
at any height with necessary nut and
hight
bolts/fasterner wherever is required
complete as per direction of Engineer-in-
charge.

ROAD SOR
218 3.1 Excavation in Soil by Manual Means
Excavation for roadway in soil including
loading in truck for carrying of cut earth to
embankment site with all lifts and lead Cum. 15905.4 129.00 20,51,791
upto1000 metres as per clauses of section-
300.
219 3.10 Embankment Construction with Material
Obtained from
Borrow Pits Construction of embankment
with approved material having CBR>7
obtained from borrow pits with all lifts and
leads, transporting to site, spreading, Cum 14209.6 144.00 20,46,177
grading to required slope and compacting
to meet
requirement of table 300-1, 300-2 and as
per relevent clauses of section-300.

220 4.12 Crusher Run Macadam Sub Base/Base


Course
Providing crushed stone aggregate,
depositing on a prepared surface by hauling
vehicles, spreading and mixing with a
motor grader, watering and compacting
with a vibratory roller to clause
410 to form a layer of sub-base/Base in
Cum
accordance to Table No. 400-14, 400-15
and as per clause of section 407 of
specifications. Note :- This item can be
executed only after prior written approval
by C.E.

(i) For 53 mm maximum size Cum 6498.9 957.00 62,19,447


S.No S.O.R No.
Description Unit Qty Rate Amount

221 4.13 Construction of Shoulders with approved


material/selected soil i/c excavation all
lifts & leads i/c grading to required
slope & camber of 4% and compacting
using vibratory roller of 80 to 100 kN static
weight to meet requirement as per
relevant clause of 400.

B Hard Shoulders (CBR value >12) cum 2859.6 181.00 5,17,582


222 6.1 Dry Lean Cement Concrete Sub- base
Construction of dry lean cement concrete
Sub- base over a prepared sub-grade with
coarse and fine aggregate conforming to IS:
383, the size of coarse aggregate not
exceeding 25 mm, aggregate cement ratio
not to exceed 15:1, aggregate gradation
after blending to be as per table 600-1,
cement content not to be less than 150 kg/
cum, optimum moisture content to be
determined Cum 1257.5 2,049.00 25,76,577
during trial length construction, concrete
strength not to be less than 10 Mpa at 7
days, mixed in a batching plant,
transported to site, laid with a paver with
electronic sensor, compacting with 8- 10
tonnes vibratory roller, finishing and curing
as per clause 601 of specification complete
in all respect.
S.No S.O.R No.
Description Unit Qty Rate Amount

223 6.4 (Deduct Rs. 350 from item rate because of


item no. 6.5) Cement Concrete Pavement
Construction of un-reinforced, dowel
jointed, plain cement concrete pavement M-
30 grade concrete over a prepared sub base
with cement , coarse and fine aggregate
conforming to IS 383, maximum size of
coarse aggregate not exceeding 25 mm,
mixed in a batching and mixing plant as per
approved mix design, transported to site,
laid with a fixed form or slip form paver,
spread, compacted and finished in a
continuous operation including provision of
contraction, expansion, construction and Cum 3006.0 4,491.00 1,34,99,946
longitudinal joints, joint filler, separation
membrane, sealant primer, joint sealant,
debonding strip, admixtures as approved,
curing compound, finishing to lines and
grades as per drawing as per IRC 15 2011
and as per relevant clauses of section 602
of specifications complete but excluding
cost of steel in dowel bar and tie rods etc.

224 6.12 Add extra in Item No.6.3, 6.4, 6.6 & 6.10
above for the cost of steel in dowel bar and
tie rod including craddle, laps etc. complete
required as per design.
I) Mild steel M.T. 9.5 54,837.00 5,22,597
225 6.13 Providing and laying reinforced cement
concrete pipe 300mm dia NP-4 for service
R.M. 712.5 713.00 5,08,013
ducts below concrete pavement.
S.No S.O.R No.
Description Unit Qty Rate Amount

226 6.16 Providing and laying factory made


coloured chamfered edge Cement
Concrete paver blocks of required strength,
thickness and size/shape, made by table
vibratory method using PU mould, laid
in required colour and pattern over 50mm
thick compacted bed of stone dust,
compacting and proper embedding/laying
of inter locking paver blocks into the
bedding layer through vibratory
compaction by using plate vibrator, filling
the joints with sand and cutting of paver
blocks as per required size and pattern,
finishing and sweeping extra sand
including locking edges with M 15
cement concrete in footpath, light traffic
parking etc. complete as per direction of
Engineer-in-Charge.

i) 100mm thick C.C. paver block of M-35


grade with approved colour, design and Sqm 8479.0 761.00 64,52,519
pattern.

Total Amount of "SOR Civil Work" 2,68,85,90,360


NON SOR CIVIL WORK
227 SOR 13.85 Providing and Applying Roto Wall finishing
system being a dispersion of inorganic fillers,
calcite, pure silica, quartz and broad spectrum
fungicides stabilized by an acrylic co-polymer, to
be applied by means of customized trowels (one
for incorporating material on base and
spreading and other for finishing) in single coat
with a coating thickness of 2.0-2-2.5mm on a
cured smooth level plaster without keying, by
the approved applicator of manufacturer, of the
approved shade as per directions for usage all
inclusive including primer coat on the base.

Add Extra for 3.5 to 4.0 mm Thickness Sqm. 53965.1 424.00 2,28,81,210
228 NON SOR Add Extra for Plaster work Adding Glass Fiber
R/F in Dry Mix Mortar @ 1 to 1.5 kg / 50 Kg of Kg 15192.0 85.00 12,91,320
Cement .
S.No S.O.R No.
Description Unit Qty Rate Amount

229 NON SOR Proving and Fixing FiberGlass Mesh in the


required width with the paste of Cement Slurry
on vertical and horizontal junctions of RCC and
brick wall including scaffolding and all lead and
lift etc. complete before plastering upt 10 meter
height.
Grid size: 5 mm x5 mm Sqm 14175.0 48.00 6,80,400
Yarn Tex: Warp-66, Weft-33
Density: Warp-10, Weft-10
Treated Woven Mass: 45 G/M2
Woven Structure: LENO
Resin Content: 18 %
Tensile Strength: Warp >600, Weft >420.
230 NON SOR Providing & Laying Beloew Ground Perforated
PVC Pipe (For Perimeter Drain)150mm Dia to
withstand working Pressure of 6kg/Sqcm solid
pipe confirming ti IS 13592 & IS 4985 Including
Jointing with Seal Ring & perforation Rate of Meter 1114.0 680.00 7,57,520
5mm @200mmc/c including all necessary fitings
etc Complete. Excavation To Be PAid Seperatly.

231 NON SOR Providing , Laying & Covering Perforated PVC


Pipe witrh
Polypropylene Geotextile Sheet @ 150g/sm & Sqm 2897.8 177.00 5,12,911
Filling with Gravel & includes fixing All Fittings
etc Complete.
232 Item No.5.44 Providing and fixing of expansion joint
DSR 2016 system related with floor location
as per drawings and direction of Engineer-
In-Charge. The joints system
will be of extruded aluminum base
members, self aligning / self centering
arrangement and support plates etc. as per
ASTM B221-02. The system
shall be such that it provides floor to floor
/floor to wall expansion control
system for various vertical locations in load
application areas that
accommodates multi directional seismic
movement without stress to
it's components. System shall consist of
metal profiles with a universal
aluminum base member designed to
accommodate various project
conditions and finish floor treatments.
S.No S.O.R No.
Description Unit Qty Rate Amount

The cover plate shall be designed


of width and thickness required to satisfy
projects movement and
loadingrequirements and secured to base
members by utilizing manufacturer’s pre-
engineered self-centering arrangement that
freely rotates / moves in all directions. The
Self - centering arrangement shall exhibit
circular sphere ends that lock and slide
inside the corresponding aluminum
extrusion cavity to allow freedom of
movement and flexure in all directions
including vertical displacement. Provision
of Moisture Barrier Membrane
in the Joint System to have watertight joint
is mandatory requirement
all as per the manufactures design and as
approved by Engineer -in-
Charge. (Material shall conform to ASTM
6063).

Floor Joint of 150 mm gap Metre 2500.0 5,246.95 1,31,17,375


233 Item No.5.45 Providing and fixing of expansion joint
DSR 2016 system related with wall joint (internal/
external) location as per drawings and
direction of Engineer-In- Charge.
The joints shall be of extruded aluminum
base members, self aligning /
centering arrangement and support plates
as per ASTM B221- 02. The
material shall be such that it provides an
Expansion Joints System
suitable for vertical wall to wall/ wall to
corner application, both new and
existing construction in office Buildings &
complexes with no slipping
down tendency amongst the components
of the Joint System. The Joint
System shall utilize light weight aluminum
profiles exhibiting minimal
exposed aluminum surfaces mechanically
snap locking the multicellular
to facilitate movement. (Material shall
conform to ASTM 6063.)

Wall Joint of 150 mm gap Metre 2860.0 3,992.53 1,14,18,636


S.No S.O.R No.
Description Unit Qty Rate Amount

234 Item No.5.46 Providing and fixing of expansion joint


DSR 2016 system of approved make and
manufacture for various roof locations as
per approved drawings and
direction of Engineer-In-Charge. The joints
shall be of extruded aluminum
base members with, self aligning and self
centering arragement support
plates as per ASTM B221-02. The system
shall be such that it provides
water tight roof to roof /roof to corner joint
cover expansion control system that is
capable of accommodating multidirectional
seismic movement without stress to its
components. System shall consist of metal
profile that incorporates a universal
aluminum base member designed to
accommodate various project conditions
and roof treatments.

The cover plate shall be designed of width


and thickness required to satisfy movement
and loading requirements and secured to
base members by utilizing manufacturer’s
pre-engineered self-centering arrangement
that freely rotates / moves in all directions.
The Self centering arrangement shall
exhibit circular sphere ends that lock and
slide inside the corresponding aluminum
extrusion cavity to allow freedom of
movement and flexure in all directions
including vertical displacement. The Joint
System shall resists damage or
deterioration from the impact of falling ice,
exposure to UV, airborne contaminants and
occasional foot traffic from maintenance
personnel. Provision of Moisture Barrier
Membrane in the Joint System to have
water tight joint is mandatory requirement.
(Material shall confirm to ASTM 6063.)

Roof Joint of 150 mm gap Metre 250.0 4,410.67 11,02,668


S.No S.O.R No.
Description Unit Qty Rate Amount

Fire Fighting System ( NON SOR)


Piping
235 NON SOR Supplying, installing, testing and
commissioning of G.I. Pipes confirming to
IS 1239 Pt - I Heavy grade with painting,
suitable type of supports, anchor fasteners,
bolts nuts ( Galvanised), clamps, "U" bolts,
fittings such as Reducers,Tees, elbows,
flanges. Including cutting, Welding, fixing in
/ on walls, ceiling by using suitable supports
etc, as per drawings. The quoted rate shall
also include for chasing / chipping walls and
making them good with filler material and
finished in cement morter etc. complete.

300mm rmt. 20.0 7,276.00 1,45,520


250mm rmt. 20.0 6,080.00 1,21,600
236 NON SOR Supply, installation, testing &
commissioning of C.I Gate Valves with
Supervisary Switch with end flanges, nut,
bolts and accessories complete. Gate valves
with accessories shall be UL Listed / FM
approved type. Complete as per technical
specification & drawing details.

300mm Nos. 20.0 70,899.00 14,17,980


250mm Nos. 20.0 60,756.00 12,15,120
200mm Nos. 20.0 37,542.00 7,50,840
237 NON SOR Supplying, installing, testing and
commissioning of Gun metal chrome
finished Ball valves with fittings of
screwed end type. (PN 16)
15mm Nos. 50.0 899.00 44,950
238 NON SOR Supplying, installing and commissioning
C.I.flanged "Y" type Strainer with SS
mesh,suitable flanges, nuts, bolts,
gaskets etc. complete.

100mm Nos. 0.0 10,609.00 0


150mm Nos. 10.0 21,362.00 2,13,620
200mm Nos. 0.0 39,850.00 0
S.No S.O.R No.
Description Unit Qty Rate Amount

239 NON SOR Supply, installation, testing &


commissioning of C.I Non Return Valves
with end flanges, nut, bolts and accessories
complete. C.I Non Return Valves with
accessories shall be UL Listed / FM
approved type. Complete as per technical
specification & drawing details..

150mm Nos. 34.0 31,434.00 10,68,756


50mm Nos. 16.0 6,540.00 1,04,640
240 NON SOR Providing and fixing pressure transducer
(dial type pressure gauge with isolation
cock) in MS pipe line (dial diametre 100mm
pressure range 0-l0 kg/cm) suitable for 12 Nos. 52.0 1,741.00 90,532
volts /24 DC. Including connection etc. as
required.

241 NON SOR Providing & fixing double flanged flexicon


expansion joint (expansion bellows) of
standard length as per manufacturers specs
including rubber gaskets, flanges, nuts,
bolts and washers complete as required.

80 mm dia Nos. 2.0 4,087.00 8,174


100 mm dia Nos. 2.0 4,809.00 9,618
150 mm dia Nos. 8.0 6,854.00 54,832
200 mm dia Nos. 1.0 10,463.00 10,463
242 NON SOR Providing, fixing, testing & commissioning
of butterfly valve (suitable for test pressure of
16 kg / sqcm) with flanges, nut bolts, gaskets,
painting and necessary pad locking
arrangement complete required.

100MM Nos. 8.0 4,604.00 36,832

243 NON SOR Supply, installation, testing and


commissioning single interlock delgue valve
operated through flow switch including air
compressor and panel, soleniod valve,
Set 4.0 1,56,617.00 6,26,468
check valve , gate valve, wiring, conduting
etc. complete for automatic operation of
water curtain in upper and lower
basement.

244 NON SOR Supply, installation, testing and


commissioning high pressure resistance
nozzle (15mm Dia) for water curtain in Each 105.0 877.00 92,085
lower and upper basement area.
S.No S.O.R No.
Description Unit Qty Rate Amount

245 NON SOR Providing and fixing mechanical foam


type Trolley Mounted Fire Extinguisher
of bearing to IS:10568/IS13385/IS13386
with dis
Capacity 50 Kg. Nos. 2.0 15,893.00 31,786

Internal Sprinkler & Hydrant


246 NON SOR Supplying, installing, testing and
commissioning Quick Response Sprinkler
quartzoid bulb type with screwed end
connection Sprinklers shall be UL Listed /
FM approved with Chrome finished.

246 (A) 15 mm dia - Rating 79°C ( Pendent Type ) K-


Nos. 150.0 442.00 66,300
80 with Rossette
246 (B) 15 mm dia ( Horizontal side wall Extended
Coverage) K-80 with Rossette Nos. 80.0 396.00 31,680

247 NON SOR Supply, erection, testing & commissioning


of S.S Flexible Pipes for Sprinkler
Connection
247 (A) 1500mm
Nos. 1800.0 1,676.00 30,16,800

247 (B) 1000mm


Nos. 1300.0 1,396.00 18,14,800

247 (C) 700mm


Nos. 850.0 1,257.00 10,68,450
248 NON SOR Supplying, installing, testing and
commissioning of 25mm dia Inspection and
Testing assembly with GM sight glass, GM
Nos. 850.0 2,607.00 22,15,950
isolation, by pass valves and connected to
drain line complete ( excluding the cost of
drain pipe)
249 NON SOR Gun metal Air Purge Valve with ball valve &
10.0 372.00 3,720
other accessories
S.No S.O.R No.
Description Unit Qty Rate Amount

250 NON SOR Surface Preparation and application of


crystalline
waterproof coating
Supply & Application of waterproofing for
Basement with
Aquafin IC, a single component, crystalline,
breathable and
crack healing, Cementitious coating system
by Surface coating
method. Waterproofing consists of
Surface preparation, strengthening and
grouting with cement Sqm 14213.0 620.00 88,12,060
grout admixing Grout ADD after packing
the joints,
barring the inserted nozzles.
After effectively arresting of cross leakages,
apply
Aquafin IC, a single component crystalline,
breathable, crack
healing water proof coating @ 2 Kgs/m2 in
two coat. Do the
second coat after first coat is tack free.
Needs curing with water for 3 days

Total Amount of "NON SOR Civil Work" Total 7,48,35,615


TOTAL OF SOR AND NON SOR AMOUNT OF CIVIL WORK Rs. 2,76,34,25,975