RS 3000 Advance LiteE 12P 1-1
RS 3000 Advance LiteE 12P 1-1
RS 3000 Advance LiteE 12P 1-1
450 mm 450 mm
Anterior segment module (optional)
Software analysis Corneal thickness measurement
Corneal thickness map
472 mm
472 mm
Angle measurement
620 mm
620 mm
932 mm
932 mm
PC rack (optional)
Dimensions / Mass 620 (W) x 450 (D) x 700 (H) mm / 29 kg
24.4 (W) x 17.7 (D) x 27.6 (H)“ / 64 lbs.
HEAD OFFICE TOKYO OFFICE NIDEK INC. NIDEK S.A. NIDEK TECHNOLOGIES S.R.L. NIDEK (SHANGHAI) CO., LTD. NIDEK SINGAPORE PTE. LTD.
(International Div.) (International Div.) 47651 Westinghouse Drive, Europarc, Via dell’Artigianato, #915, China Venturetech Plaza, 51 Changi Business Park
34-14 Maehama, Hiroishi 3F Sumitomo Fudosan Hongo Fremont, CA 94539, U.S.A. 13 rue Auguste Perret, 6/A, 35020 Albignasego (Padova), 819 Nanjing West Rd, Jing An Central 2, #06-14, The
Gamagori, Aichi 443-0038, Bldg., 3-22-5 Hongo, Bunkyo-ku, TEL: +1-510-226-5700 94042 Créteil, FRANCE ITALY District, Shanghai 200041, Signature 486066,
JAPAN Tokyo 113-0033, JAPAN +1-800-223-9044 TEL: +33-1-49 80 97 97 TEL: +39 049 8629200 / 8626399 CHINA SINGAPORE
TEL: +81-533-67-8895 TEL: +81-3-5844-2641 (US only) URL: http://www.nidek.fr URL: http://www.nidektechnologies.it TEL: +86 021-5212-7942 TEL: +65 6588 0389
URL: http://www.nidek.com URL: http://www.nidek.com URL: http://usa.nidek.com URL: http://www.nidek-china.cn
[ Manufacturer ]
* AngioScan (OCT-Angiography) is optional software. Image courtesy of Eric Souied, MD, PhD,
Centre Hospitalier Intercommunal de Creteil
See it with selectable OCT sensitivity. See it with a wide area normative database.
Ultra fine
* AngioScan (OCT-Angiography) is optional software. Image courtesy of Eric Souied, MD, PhD,
Centre Hospitalier Intercommunal de Creteil
See it with selectable OCT sensitivity. See it with a wide area normative database.
Ultra fine
Tracing HD
Macula Comparison
Tracing HD Ultra fine Choroidal • Users can select two images for
comparison.
Before treatment After treatment • Chronological change in retinal thickness
can be analyzed with a graph indicating its
trend by designating the area on the
PVD (Posterior Vitreous Detachment) thickness graph based on user preference.
Enhanced image function allows greater resolutions of vitreous retina images by adjusting brightness of
weak OCT signals. Thickness graph
En face OCT
• En face view presents frontal sections of
the retinal layers.
• Combined assessment of the B-Scan and En
face images defines the shape and the
extension of lesions.
Ultra fine Retinal
AngioScan
• AngioScan images illustrate retinal
microvasculature using a non-invasive
method.
photo 未 • OCT-Angiography allows segmentation of
layers of layers of interest in exquisite
detail for greater in-depth
evaluation.
Tracing HD
Macula Comparison
Tracing HD Ultra fine Choroidal • Users can select two images for comparison.
• Chronological change in retinal thickness
Before treatment After treatment can be analyzed with a graph indicating its
trend by designating the area on the
thickness graph based on user preference.
PVD (Posterior Vitreous Detachment)
Enhanced image function allows greater resolutions of vitreous retina images by adjusting brightness of
weak OCT signals. Thickness graph
En face OCT
• En face view presents frontal sections of
the retinal layers.
• Combined assessment of the B-Scan and En
face images defines the shape and the
extension of lesions.
Ultra fine Retinal
AngioScan
• AngioScan images illustrate retinal
microvasculature using a non-invasive
method.
photo 未 • OCT-Angiography allows segmentation of
layers of interest in exquisite detail for
greater in-depth evaluation.
Vessel flow area Density of vessel flow area FAZ (Foveal Avascular Zone)
Neovascular maculopathy
Flexible Functions
• The tracing HD function tracks eye movements to
maintain the same scan location on the SLO image Clinical Case
High Tracing ON
for accurate image capture. 4 HD 1. En face / OCT-Angiography, CNV
• Based on the clinical requirement, the tracing function
Tracing ON
can be set for high definition and high contrast
Image quality
2 HD
En face
imaging. Images can also be captured within seconds
without the tracing function. Tracing OFF
• Two- or four- scan per line (2HD, 4HD) can be selected. 4 HD
Four-scan per line provides high quality images
Tracing OFF
combined with the tracing HD function. 2 HD
OCT-Angiography
• Up to 12 x 9 mm panorama image can be composed. Low
Low Acquisition speed High
• Scan size can range from 3 mm to maximum of 9 mm.
Up to 12 mm
1 2 3 4 2. CNV 3. BRVO 4. GA
5 6 7 8
Up to 9 mm
Panorama image Images courtesy of Eric Souied, MD, PhD, Centre Hospitalier Intercommunal de Creteil
Edoardo Midena, MD, PhD and Elisabetta Pilotto MD, University of Padova
AngioScan
OCT-Angiography Analytics
This non-invasive method does not require contrast dye injection for examination of the layer-by-layer
microvasculature within the retina and choroid. Radial peripapillary capillary plexus, superficial capillary
plexus, internal capillary plexus and deep capillary plexus can be analyzed. Images of the superficial
capillary, deep capillary, outer retina and choroid can be displayed for clinical evaluation.
Vessel flow area Density of vessel flow area FAZ (Foveal Avascular Zone)
Neovascular maculopathy
Flexible Functions
• The tracing HD function tracks eye movements to
maintain the same scan location on the SLO image Clinical Case
High Tracing ON
for accurate image capture. 4 HD 1. En face / OCT-Angiography, CNV
• Based on the clinical requirement, the tracing function
Tracing ON
can be set for high definition and high contrast
Image quality
2 HD
En face
imaging. Images can also be captured within seconds
without the tracing function. Tracing OFF
• Two- or four- scan per line (2HD, 4HD) can be selected. 4 HD
Four-scan per line provides high quality images
Tracing OFF
combined with the tracing HD function. 2 HD
OCT-Angiography
• Up to 12 x 9 mm panorama image can be composed. Low
Low Acquisition speed High
• Scan size can range from 3 mm to maximum of 9 mm.
Up to 12 mm
2. CNV 3. BRVO 4. GA
1 2 3 4
5 6 7 8
Up to 9 mm
Panorama image Images courtesy of Eric Souied, MD, PhD, Centre Hospitalier Intercommunal de Creteil
Edoardo Midena, MD, PhD and Elisabetta Pilotto MD, University of Padova
NAVIS-EX
NAVIS-EX is an image filing software,
which networks the RS-3000 Advance / Lite Examination room
and other NIDEK diagnostic devices. This Consultation
room 1
functionality enhances the capability of
the diagnostic device with additional
features and increases clinical efficiency.
Consultation
room 2
The OCT for general screening
• Analysis and report Providing the high resolution OCT images and clinically useful analyses, the RS-3000 Lite achieves the optimum balance
• Normative database Consultation between cost and performance with its fundus surface imaging system. The RS-3000 Lite has been developed for
room 3 screening in general eye clinics.
• Long axial length normative database
(optional software)
NAVIS-EX Viewer
• DICOM connectivity
SLO (12 fps frame rate) OCT phase fundus (1.8 fps frame rate)
40º x 30º angle of view 36º x 30º angle of view
SLO (12 fps frame rate) OCT phase fundus (1.8 fps frame rate)
40º x 30º angle of view 36º x 30º angle of view
Anterior Segment Analysis Scan pattern (retina) Macula line (scan angle changeable by 1º)
Macula cross
Macula line (scan angle changeable by 15º)
Macula map (with cross scan / without cross scan)
The optional anterior segment module enables observation and analyses of the anterior segment. Macula map (with cross scan / without cross scan) Macula multi (X-Y: 5 x 5)
Macula multi (X-Y: 5 x 5) Disc map
Macula radial (6 lines / 12 lines)
• ACA
Disc circle
Angle between posterior corneal surface and iris surface
Disc map
• AOD500 (AOD750)
Disc radial (6 lines / 12 lines)
Distance between iris and a point 500 µm (or 750 µm)
Scan pattern (cornea) Cornea line Cornea radial (6 lines / 12 lines)
away from scleral spur on posterior corneal surface
with optional anterior segment module Cornea cross ACA line
• TISA500 (TISA750)
Cornea radial (6 lines / 12 lines)
Area circumscribed with AOD500 (or AOD750) line,
ACA line
posterior corneal surface, line drawn from scleral
Image averaging Up to 120 images Up to 50 images
Angle measurement spur in parallel with AOD line, and iris surface
Choroidal mode Available Not available
Torsion eye tracer Available Not available
• Corneal thickness Not available
Follow-up tracing Available
Corneal thickness of apex and Follow-up analysis Available
user’s preferred sites Tracing HD Available Not available
HD checker Available Not Available
• Corneal thickness map Flexible cross scan Available Not Available
Map indicating corneal Anterior segment adaptor
Select and rescan mode Available Not Available
thickness measured in Auto shot (for follow-up image capture) Available Not available
Cornea measurement radial directions Internal fixation target Cross shape (laser) Circle shape (LED)
PC monitor 21" 17"
RS-3000 Advance / Lite Specifications
Model RS-3000 Advance RS-3000 Lite
Optical Coherence Tomography
OCT scanning
Principle
Optical resolution
Scan range
Spectral domain OCT
Z: 7 µm, X-Y: 20 µm
X: 3 to 12 mm
Y: 3 to 9 mm
X: 3 to 9 mm
Y: 3 to 9 mm
RS-3000 Advance / Lite
Z: 2.1 mm Z: 2.1 mm
Digital resolution Z: 4 µm, X-Y: 3 µm
OCT light source SLD, 880 nm
Scan speed Up to 53,000 A-scans / s
Internal fixation lamp 637 nm 660 nm
External fixation lamp 630 / 565 nm
Auto alignment Z direction
Minimum pupil diameter ø2.5 mm
Focus adjustment range -15 to +10 D (VD=12 mm)
Working distance 35.5 mm
Software analysis Segmentation of 6+1 retinal layers
Macular thickness map
RNFL thickness map
[NFL+GCL+IPL] analysis
Optic nerve analysis
Follow-up analysis
Fundus surface imaging
Principle Confocal scanning laser ophthalmoscope OCT phase fundus
(SLO light source: 785 nm)
Angle of view 40º x 30º (zoom: 20º x 15º) 36º x 30º
PC networking Available
Display Tiltable 8.4-inch color LCD
Power supply AC 100, 120, 230 V
50 / 60 Hz
Power consumption 300 VA
Maximum power output 1,000 VA
(transformer)
Dimensions / Mass 380 (W) x 524 (D) x 499 to 531 (H) mm / 34 kg 380 (W) x 524 (D) x 499 to 531 (H) mm / 33 kg
15.0 (W) x 20.6 (D) x 19.6 to 20.9 (H)“ / 75 lbs. 15.0 (W) x 20.6 (D) x 19.6 to 20.9 (H)“ / 73 lbs.
Optional accessories Anterior segment module, motorized optical Anterior segment module, motorized optical
table, PC rack, long axial length normative table, PC rack, long axial length normative
database, OCT-Angiography database
450 mm 450 mm
Anterior segment module (optional)
Software analysis Corneal thickness measurement
Corneal thickness map
472 mm
472 mm
Angle measurement
620 mm
620 mm
932 mm
932 mm
PC rack (optional)
Dimensions / Mass 620 (W) x 450 (D) x 700 (H) mm / 29 kg
24.4 (W) x 17.7 (D) x 27.6 (H)“ / 64 lbs.
HEAD OFFICE TOKYO OFFICE NIDEK INC. NIDEK S.A. NIDEK TECHNOLOGIES S.R.L. NIDEK (SHANGHAI) CO., LTD. NIDEK SINGAPORE PTE. LTD.
(International Div.) (International Div.) 47651 Westinghouse Drive, Europarc, Via dell’Artigianato, #915, China Venturetech Plaza, 51 Changi Business Park
34-14 Maehama, Hiroishi 3F Sumitomo Fudosan Hongo Fremont, CA 94539, U.S.A. 13 rue Auguste Perret, 6/A, 35020 Albignasego (Padova), 819 Nanjing West Rd, Jing An Central 2, #06-14, The
Gamagori, Aichi 443-0038, Bldg., 3-22-5 Hongo, Bunkyo-ku, TEL: +1-510-226-5700 94042 Créteil, FRANCE ITALY District, Shanghai 200041, Signature 486066,
JAPAN Tokyo 113-0033, JAPAN +1-800-223-9044 TEL: +33-1-49 80 97 97 TEL: +39 049 8629200 / 8626399 CHINA SINGAPORE
TEL: +81-533-67-8895 TEL: +81-3-5844-2641 (US only) URL: http://www.nidek.fr URL: http://www.nidektechnologies.it TEL: +86 021-5212-7942 TEL: +65 6588 0389
URL: http://www.nidek.com URL: http://www.nidek.com URL: http://usa.nidek.com URL: http://www.nidek-china.cn
[ Manufacturer ]