A320-34-1620 R06 DT 22.07.2019
A320-34-1620 R06 DT 22.07.2019
A320-34-1620 R06 DT 22.07.2019
SERVICE BULLETIN
CONF ALL
AIRBUS
2, ROND POINT EMILE DEWOITINE
31700 BLAGNAC
FRANCE
The content of this document is the property of Airbus.
It is supplied in confidence and commercial security on its contents must be maintained.
It must not be used for any purpose other than that for which it is supplied, nor may information
contained in it be disclosed to unauthorized persons.
It must not be reproduced in whole or in part without permission in writing from the owners of the
copyright. Requests for reproduction of any data in this document and the media authorized for it must
be addressed to Airbus.
ATA SYSTEM: 34
SERVICE BULLETIN
General SB data are transformed from ATA iSpec 2200 norm to
ASD S1000D norm.
Revised text and layout changes of this revision are
not identified with revision bars.
CONF 002
SERVICE BULLETIN
General SB data are transformed from ATA iSpec 2200 norm to
ASD S1000D norm.
Revised text and layout changes of this revision are
not identified with revision bars.
SUMMARY
APPLICABILITY Aircraft operator updated.
CONF 003
SERVICE BULLETIN
General SB data are transformed from ATA iSpec 2200 norm to
ASD S1000D norm.
Revised text and layout changes of this revision are
not identified with revision bars.
SUMMARY
APPLICABILITY Aircraft operators updated.
CONF 004
SERVICE BULLETIN
General SB data are transformed from ATA iSpec 2200 norm to
ASD S1000D norm.
Revised text and layout changes of this revision are
not identified with revision bars.
SUMMARY
APPLICABILITY Addition of new aircraft.
MODIFICATION CLASSIFICATION
MAJOR None
MINOR 32467P7418
NOTE: As per EASA IR 21, a minor change is one that has no appreciable effect on the
mass, balance, structural strength, reliability, operational characteristics affecting
the airworthiness of the product. All other changes are major changes.
CONF 002
MODIFICATION CLASSIFICATION
MAJOR None
MINOR 32467P7418
NOTE: As per EASA IR 21, a minor change is one that has no appreciable effect on the
mass, balance, structural strength, reliability, operational characteristics affecting
the airworthiness of the product. All other changes are major changes.
CONF 003
MODIFICATION CLASSIFICATION
MAJOR None
MINOR 32467P7418
NOTE: As per EASA IR 21, a minor change is one that has no appreciable effect on the
mass, balance, structural strength, reliability, operational characteristics affecting
the airworthiness of the product. All other changes are major changes.
CONF 004
MODIFICATION CLASSIFICATION
MAJOR None
MINOR 32467P7418
NOTE: As per EASA IR 21, a minor change is one that has no appreciable effect on the
mass, balance, structural strength, reliability, operational characteristics affecting
the airworthiness of the product. All other changes are major changes.
CONF ALL
B. REASON
- Air Traffic Service Unit (ATSU) (if ATSU provisions (modification No. 26878P4500
(INSTALL ATSU SYSTEM PROVISIONS) installed) and ATC/Mode S Transponder 1/2
- Inertial Reference System (IRS) and ATC/Mode S Transponder 1/2
- Flight Control Unit (FCU) and ATC/Mode S Transponder 1/2
- Multi-Mode Receiver (MMR) (if installed) and ATC/Mode S Transponder 1/2 (wiring
provision installed but the wires are stowed on both sides).
(3) Advantages
Accomplishment of this Service Bulletin will satisfy the operator's request.
(4) Operational/Maintenance Consequences
None
C. GENERAL EVALUATION
EVALUATION TABLE
COMPLIANCE OPTIONAL COST SAVING NO
A/C OPERATION NO VENDOR SB NO
AFFECTED
CANCELS INSPECTION SB NO ETOPS AFFECTED NO
PAX COMFORT AFFECTED NO POTENTIAL AD NO
RELIABILITY AFFECTED NO STRUCTURAL LIFE EXTENSION NO
LIFE LIMIT NO LINE MAINTENANCE AFFECTED NO
D. MAINTENANCE CONFIGURATION
CONF 001
No specific aircraft maintenance configuration required.
CONF 002
No specific aircraft maintenance configuration required.
CONF 003
No specific aircraft maintenance configuration required.
CONF 004
No specific aircraft maintenance configuration required.
CONF ALL
E. MATERIAL PRICE INFORMATION
CONF 001
(1) Modification
G. CONCURRENT REQUIREMENTS
None
H. NATURE OF THE WORK
CONF 001
(1) Modification
(a) Task set A320-A-34-XX-1620-01000-93AA-A Modification
AIRCRAFT YES
EQUIPMENT NO
CONF 002
(1) Modification
(a) Task set A320-A-34-XX-1620-01000-93AA-A Modification
AIRCRAFT YES
EQUIPMENT NO
CONF 003
(1) Modification
(a) Task set A320-A-34-XX-1620-01000-93AA-A Modification
AIRCRAFT YES
EQUIPMENT NO
CONF 004
(1) Modification
(a) Task set A320-A-34-XX-1620-01000-93AA-A Modification
AIRCRAFT YES
EQUIPMENT NO
CONF ALL
I. MANPOWER
CONF 001
(1) Modification
(a) Task set A320-A-34-XX-1620-01000-93AA-A Modification
MANPOWER
TOTAL MAN-HOURS 85.00 h
ELAPSED TIME (HOURS) 73.00 h
CONF 002
MANPOWER
TOTAL MAN-HOURS 55.00 h
ELAPSED TIME (HOURS) 55.00 h
CONF 003
(1) Modification
(a) Task set A320-A-34-XX-1620-01000-93AA-A Modification
MANPOWER
TOTAL MAN-HOURS 85.00 h
ELAPSED TIME (HOURS) 73.00 h
CONF 004
(1) Modification
(a) Task set A320-A-34-XX-1620-01000-93AA-A Modification
MANPOWER
TOTAL MAN-HOURS 85.00 h
ELAPSED TIME (HOURS) 73.00 h
824 B
822
A
811
FR24
812
Z120
FR1
A
90VU
MODIFICATION OF THE WIRING IN
THE RELAY PLATE 188VU
INSTALLATION OF THE MODULES AND MODIFICATION
OF THE WIRING IN THE AFT ELECTRONICS RACK 80VU
B
80VU
ICN-A320-A-34XX1620-A-FAPE3-00MFZ-A-003-01
824 A
FR24
Z120
FR1
A
80VU
ICN-A320-A-34XX1620-A-FAPE3-00MG0-A-002-01
ATA SYSTEM: 34
MSN CONFIGURATION
00302 001
CONF 002
MSN CONFIGURATION
00357 00447 002
CONF 003
MSN CONFIGURATION
01541 01551 01684 01703 02044 02236 02240 02480 003
CONF 004
MSN CONFIGURATION
02193 02405 02422 02430 02482 004
CONF ALL
(4) Configuration definition
CONF 001
Configuration 001
CONF 001 regards the specific PRE-SB status of the related aircraft.
CONF 001 retrofits following modifications: 32467P7418.
CONF 002
Configuration 002
CONF 002 regards the specific PRE-SB status of the related aircraft.
CONF 002 retrofits following modifications: 32467P7418.
CONF 003
Configuration 003
CONF 003 regards the specific PRE-SB status of the related aircraft.
CONF 003 retrofits following modifications: 32467P7418.
CONF 004
Configuration 004
CONF 004 regards the specific PRE-SB status of the related aircraft.
CONF 004 retrofits following modifications: 32467P7418.
CONF ALL
B. CONCURRENT REQUIREMENTS
None
C. REASON
(1) History
This Service Bulletin is issued further to an operator's request in order to prepare the
aircraft for the European requirement related to enhanced surveillance.
(2) Objective/Action
This Service Bulletin installs the wiring provisions between Air Traffic Control (ATC)
transponder and the peripherals in order to allow activation of enhanced surveillance.
The modification consists in installing wiring between:
- Air Traffic Service Unit (ATSU) (if ATSU provisions (modification No. 26878P4500
(INSTALL ATSU SYSTEM PROVISIONS) installed) and ATC/Mode S Transponder 1/2
- Inertial Reference System (IRS) and ATC/Mode S Transponder 1/2
- Flight Control Unit (FCU) and ATC/Mode S Transponder 1/2
- Multi-Mode Receiver (MMR) (if installed) and ATC/Mode S Transponder 1/2 (wiring
provision installed but the wires are stowed on both sides).
(3) Advantages
Accomplishment of this Service Bulletin will satisfy the operator's request.
(4) Operational/Maintenance Consequences
None
D. DESCRIPTION
To accomplish this Service Bulletin it is necessary to:
(1) Modification
(a) Task set A320-A-34-XX-1620-01000-93AA-A Modification
CONF 001
1 Modify the Equipment and the Wiring in the Aft Electronics Rack 80VU
CONF 002
1 Modify the Equipment and the Wiring in the Aft Electronics Rack 80VU
CONF 003
1 Modify the Equipment and the Wiring in the Aft Electronics Rack 80VU
CONF 004
1 Modify the Equipment and the Wiring in the Aft Electronics Rack 80VU
CONF 001
2 Remove the Shelves 95VU and 96VU, for Access
CONF 003 004
2 Remove the Shelves 95VU and 96VU, for Access
CONF 001
3 Modify the Wiring in the Shelves 95VU and 96VU, on Bench
CONF 003 004
3 Modify the Wiring in the Shelves 95VU and 96VU, on Bench
CONF 001
4 Install the Shelves 95VU and 96VU
CONF 003 004
4 Install the Shelves 95VU and 96VU
CONF 001 003 004
5 Modify the Wiring between the Aft Electronics Rack 80VU and the FWD
Electronics Rack 90VU
CONF ALL
E. COMPLIANCE
(1) Classification
OPTIONAL: Service Bulletin for convenience or option.
PREPARATION
Job Set-up 10.00 h
PROCEDURE
Modify the Equipment and the Wiring in the Aft Electronics 47.00 h
Rack 80VU
Remove the Shelves 95VU and 96VU, for Access 5.00 h
Modify the Wiring in the Shelves 95VU and 96VU, on Bench 2.00 h BENCH
Install the Shelves 95VU and 96VU 5.00 h
Modify the Wiring between the Aft Electronics Rack 80VU 2.00 h
and the FWD Electronics Rack 90VU
PREPARATION FOR TEST
Job Set-up 1.00 h
TEST
Test 3.00 h
CLOSE-UP
Close-up 10.00 h
TOTAL MAN-HOURS 85.00 h
ELAPSED TIME (HOURS) 73.00 h
NOTE: For an explanation of the man-hours and elapsed time, refer to the
Gantt Chart given in Appendix MANPOWER GANTT CHART.
CONF 002
The manpower estimates given in this Service Bulletin are based on the direct labor cost to
do the work. These estimates assume that the work will be done by experienced personnel,
and may need to be revised upwards to suit operator’s circumstances. The estimates do not
include the time to prepare, plan or inspect the work. Manufacture and procurement of parts
and tools, drying times for paints, sealants, etc., and general administration work are also
not included.
(1) Modification
(a) Task set A320-A-34-XX-1620-01000-93AA-A Modification
PREPARATION
Job Set-up 8.00 h
PROCEDURE
Modify the Equipment and the Wiring in the Aft Electronics 35.00 h
Rack 80VU
PREPARATION FOR TEST
Job Set-up 1.00 h
TEST
Test 3.00 h
CLOSE-UP
Close-up 8.00 h
TOTAL MAN-HOURS 55.00 h
ELAPSED TIME (HOURS) 55.00 h
CONF 003
The manpower estimates given in this Service Bulletin are based on the direct labor cost to
do the work. These estimates assume that the work will be done by experienced personnel,
and may need to be revised upwards to suit operator’s circumstances. The estimates do not
include the time to prepare, plan or inspect the work. Manufacture and procurement of parts
and tools, drying times for paints, sealants, etc., and general administration work are also
not included.
(1) Modification
(a) Task set A320-A-34-XX-1620-01000-93AA-A Modification
PREPARATION
Job Set-up 10.00 h
PROCEDURE
Modify the Equipment and the Wiring in the Aft Electronics 47.00 h
Rack 80VU
Remove the Shelves 95VU and 96VU, for Access 5.00 h
Modify the Wiring in the Shelves 95VU and 96VU, on Bench 2.00 h BENCH
Install the Shelves 95VU and 96VU 5.00 h
Modify the Wiring between the Aft Electronics Rack 80VU 2.00 h
and the FWD Electronics Rack 90VU
PREPARATION FOR TEST
Job Set-up 1.00 h
TEST
Test 3.00 h
CLOSE-UP
Close-up 10.00 h
TOTAL MAN-HOURS 85.00 h
ELAPSED TIME (HOURS) 73.00 h
NOTE: For an explanation of the man-hours and elapsed time, refer to the
Gantt Chart given in Appendix MANPOWER GANTT CHART.
CONF 004
The manpower estimates given in this Service Bulletin are based on the direct labor cost to
do the work. These estimates assume that the work will be done by experienced personnel,
and may need to be revised upwards to suit operator’s circumstances. The estimates do not
include the time to prepare, plan or inspect the work. Manufacture and procurement of parts
and tools, drying times for paints, sealants, etc., and general administration work are also
not included.
(1) Modification
(a) Task set A320-A-34-XX-1620-01000-93AA-A Modification
PREPARATION
Job Set-up 10.00 h
PROCEDURE
Modify the Equipment and the Wiring in the Aft Electronics 47.00 h
Rack 80VU
Remove the Shelves 95VU and 96VU, for Access 5.00 h
Modify the Wiring in the Shelves 95VU and 96VU, on Bench 2.00 h BENCH
Install the Shelves 95VU and 96VU 5.00 h
Modify the Wiring between the Aft Electronics Rack 80VU 2.00 h
and the FWD Electronics Rack 90VU
PREPARATION FOR TEST
Job Set-up 1.00 h
TEST
Test 3.00 h
CLOSE-UP
Close-up 10.00 h
TOTAL MAN-HOURS 85.00 h
ELAPSED TIME (HOURS) 73.00 h
NOTE: For an explanation of the man-hours and elapsed time, refer to the
Gantt Chart given in Appendix MANPOWER GANTT CHART.
CONF ALL
H. WEIGHT AND BALANCE
The weight and balance estimates given in this Service Bulletin are based on the
Manufacturer's Empty Weight (MEW) and do not include operator's items. The definition of
MEW and operator's items is given in the Weight and Balance Manual (WBM), Ref. WBM.
Manufacturer's Empty Weight +0.2 kg (+0.441 lb)
Effect on Balance +2.2 kg.m (+15.913 lb.ft)
I. ELECTRICAL LOAD DATA
Not changed
J. REFERENCES
CONF 001
(1) Modification
(a) Task set A320-A-34-XX-1620-01000-93AA-A Modification
2. MATERIAL INFORMATION
A. MATERIAL APPLICABILITY
CONF 001
Material for task set A320-A-34-XX-1620-01000-93AA-A Modification
Availability
NOTE(S)
Sales terms must be agreed between the Customer and AIRBUS in accordance with
the RFC (or RFC/RMO) procedure.
Procurement address
NOTE(S)
The AIRBUS material is included in the commercial offer and as such will be supplied
by AIRBUS Upgrade Services. To facilitate the material reception, Airline Customers
are requested to contact:
Availability
NOTE(S)
Sales terms must be agreed between the Customer and AIRBUS in accordance with
the RFC (or RFC/RMO) procedure.
Procurement address
NOTE(S)
The AIRBUS material is included in the commercial offer and as such will be supplied
by AIRBUS Upgrade Services. To facilitate the material reception, Airline Customers
are requested to contact:
Availability
NOTE(S)
Sales terms must be agreed between the Customer and AIRBUS in accordance with
the RFC (or RFC/RMO) procedure.
Procurement address
NOTE(S)
The AIRBUS material is included in the commercial offer and as such will be supplied
by AIRBUS Upgrade Services. To facilitate the material reception, Airline Customers
are requested to contact:
Availability
NOTE(S)
Sales terms must be agreed between the Customer and AIRBUS in accordance with
the RFC (or RFC/RMO) procedure.
Procurement address
NOTE(S)
The AIRBUS material is included in the commercial offer and as such will be supplied
by AIRBUS Upgrade Services. To facilitate the material reception, Airline Customers
are requested to contact:
3. ACCOMPLISHMENT INSTRUCTIONS
Task set A320-A-34-XX-1620-01000-93AA-A
Modification
WARNING: MAKE SURE THAT YOU OBEY ALL THE WARNINGS AND ALL THE CAUTIONS
INCLUDED IN THE REFERENCED PROCEDURES.
NOTE: The accomplishment instructions of this Service Bulletin include procedures given in
other documents or in other sections of the Service Bulletin. When the words “refer to”
are used and the operator has a procedure accepted by the local authority he belongs to,
the accepted alternative procedure can be used. When the words “in accordance with”
are used then the given procedure must be followed.
NOTE: The access and close-up instructions, not comprising return to service tests, in this
Service Bulletin do not constitute or affect the technical intent of the Service Bulletin.
Operators can therefore, as deemed necessary, omit or add access and/or close-up steps
to add flexibility to their maintenance operations as long as the technical intent of the
Service Bulletin is met within the set parameters.
NOTE: Manual titles given in the accomplishment instructions are referred to by acronyms. Refer
to paragraph 1.J., References, for the definition of acronyms.
NOTE: This Service Bulletin contains the instructions for the on-aircraft maintenance necessary
to ensure the continued airworthiness of the aircraft.
For any deviations to the instructions, contact AIRBUS for further instructions and
approval.
CONF 003
ELAPSED TIME (HOURS) 73.00 h
CONF 004
ELAPSED TIME (HOURS) 73.00 h
CONF ALL
B. PREPARATION
CONF 001
(1) Task A320-A-34-XX-1620-01001-540A-A - Job Set-up
Job Set-Up Information
Manpower/Resources/Skills
Man-hours 10.00 h
Minimum Number of person 1
Elapsed Time 10.00 h
Referenced Information
Manuals/Drawings References/Sheets
Task 12-34-24-869-002
Task 21-31-34-000-001
Task 21-43-34-000-002
Task 21-61-34-000-001
Task 22-66-34-000-002
Task 22-83-34-000-001
Task 24-22-33-000-001
Task 24-38-51-000-001
Task 25-54-11-000-001
Task 27-93-34-000-001
AMM
Task 27-94-34-000-001
Task 31-36-34-000-001
Task 31-53-34-000-001
Task 31-63-34-000-001
Task 34-36-31-000-001
Task 34-43-34-000-001
Task 34-48-34-000-001
Task 34-52-33-000-001
Task 36-11-34-000-001
Task 52-41-00-010-002
Procedure
NOTE: For the basic Aircraft configuration, refer to AMM Chapter "Introduction -
Aircraft status for maintenance" in Manual Front Matter section.
(a) Make sure that the aircraft is electrically grounded, refer to Ref. AMM Task
12-34-24-869-002.
(b) Open the avionics compartment Door 812, refer to Ref. AMM Task
52-41-00-010-002.
(c) In the Forward (FWD) cargo compartment, at Frame 24A, remove the partition
Panel 131CW, Panel 131DW and Panel 132EW, refer to Ref. AMM Task
25-54-11-000-001.
(d) Do the job set-up procedure as specified in the removal of the Flight
Management and Guidance Computers (FMGCs) ( FIN 1CA1 and FIN 1CA2), refer
to Ref. AMM Task 22-83-34-000-001.
(e) Do the job set-up procedure as specified in the removal of the Flight
Augmentation Computers (FACs) ( FIN 1CC1 and FIN 1CC2), refer to Ref. AMM
Task 22-66-34-000-002.
(f) Do the job set-up procedure as specified in the removal of the Spoiler
Elevator Computers (SECs) ( FIN 1CE1 and FIN 1CE2), refer to Ref. AMM Task
27-94-34-000-001.
(g) Do the job set-up procedure as specified in the removal of the Elevator
Aileron Computers (ELACs) ( FIN 2CE1 and FIN 2CE2), refer to Ref. AMM Task
27-93-34-000-001.
(h) Do the job set-up procedure as specified in the removal of the Flight Warning
Computers (FWCs) ( FIN 1WW1 and FIN 1WW2), refer to Ref. AMM Task
31-53-34-000-001.
(i) Do the job set-up procedure as specified in the removal of the Display
Management Computers (DMCs) ( FIN 1WT2 and FIN 1WT3), refer to Ref. AMM
Task 31-63-34-000-001.
(j) Do the job set-up procedure as specified in the removal of the ATC/
Mode S Transponders ( FIN 1SH1 and FIN 1SH2), refer to Ref. AMM Task
34-52-33-000-001.
(k) Do the job set-up procedure as specified in the removal of the Traffic Alert
and Collision Avoidance System (TCAS) ( FIN 1SG), refer to Ref. AMM Task
34-43-34-000-001.
(l) If installed, do the job set-up procedure as specified in the removal of the Data
Management Unit (DMU) ( FIN 1TV), refer to Ref. AMM Task 31-36-34-000-001.
(m) Do the job set-up procedure as specified in the removal of the Ground Proximity
Warning Computer (GPWC) ( FIN 1WZ), refer to Ref. AMM Task 34-48-34-000-001.
(n) Do the job set-up procedure as specified in the removal of the MMRs ( FIN 40RT1
and FIN 40RT2), refer to Ref. AMM Task 34-36-31-000-001.
(o) Do the job set-up procedure as specified in the removal of the Electrical
Generation Interface Units (EGIUs) ( FIN 22XU1 and FIN 22XU2), refer to Ref.
AMM Task 24-22-33-000-001.
(p) Do the job set-up procedure as specified in the removal of the Bleed Monitoring
Computers (BMCs) ( FIN 1HA1 and FIN 1HA2), refer to Ref. AMM Task
36-11-34-000-001.
(q) Do the job set-up procedure as specified in the removal of the Cabin
Pressure Controllers (CPCs) ( FIN 11HL and FIN 12HL), refer to Ref. AMM Task
21-31-34-000-001.
(r) Do the job set-up procedure as specified in the removal of the Pack Controllers
(PCs) ( FIN 7HH and FIN 27HH), refer to Ref. AMM Task 21-61-34-000-001.
(s) Do the job set-up procedure as specified in the removal of the aft cargo heat-
controller ( FIN 10HC), refer to Ref. AMM Task 21-43-34-000-002.
(t) Make sure that the external connector(s) is (are) not connected to the aircraft
receptacle(s) External Power (EXT PWR).
(u) Put the warning notices in position on the external power receptacle to tell
persons not to connect an external power source.
(v) Make sure that the Emergency (EMER) EXIT Light (LT) pushbutton switch on the
Electrical Panel 25VU is set to OFF.
(w) In the cockpit, on the Electrical Panel 35VU, release the Battery (BAT)
pushbutton switches.
(x) Put a warning notice in position on the Electrical Panel 35VU to tell persons not
to operate the batteries.
(y) Put a warning notice in position on the Refuel/Defuel Electrical Panel 800VU to
tell persons not to operate the NORMAL BATTERY switch.
(z) Put a warning notice in position in the cockpit to tell persons not to start the
Auxiliary Power Unit (APU).
(aa) Put a warning notice in position in the cockpit to tell persons not to start the
Engine (ENG) 1,2.
(ab) Disconnect the battery connectors
1 For the job set-up, refer to the removal of the batteries, refer to Ref. AMM
Task 24-38-51-000-001.
2 Turn the knurled nut a quarter turn.
3 Disconnect the connectors.
4 Put blanking caps on the disconnected electrical connectors.
CONF 002
(1) Task A320-A-34-XX-1620-01002-540A-A - Job Set-up
Job Set-Up Information
Manpower/Resources/Skills
Man-hours 8.00 h
Minimum Number of person 1
Elapsed Time 8.00 h
Referenced Information
Manuals/Drawings References/Sheets
Task 12-34-24-869-002
Task 22-66-34-000-002
Task 22-83-34-000-001
Task 24-38-51-000-001
Task 25-54-11-000-001
Task 27-93-34-000-001
AMM Task 27-94-34-000-001
Task 31-36-34-000-001
Task 31-53-34-000-001
Task 31-63-34-000-001
Task 34-43-34-000-001
Task 34-48-34-000-001
Task 34-52-33-000-001
Procedure
NOTE: For the basic Aircraft configuration, refer to AMM Chapter "Introduction -
Aircraft status for maintenance" in Manual Front Matter section.
(a) Make sure that the aircraft is electrically grounded, refer to Ref. AMM Task
12-34-24-869-002.
(b) In the FWD cargo compartment, at Frame 24A, remove the partition
Panel 131CW, Panel 131DW and Panel 132EW, refer to Ref. AMM Task
25-54-11-000-001.
(c) Do the job set-up procedure as specified in the removal of the FMGCs ( FIN 1CA1
and FIN 1CA2), refer to Ref. AMM Task 22-83-34-000-001.
(d) Do the job set-up procedure as specified in the removal of the FACs ( FIN 1CC1
and FIN 1CC2), refer to Ref. AMM Task 22-66-34-000-002.
(e) Do the job set-up procedure as specified in the removal of the SECs ( FIN 1CE1
and FIN 1CE2), refer to Ref. AMM Task 27-94-34-000-001.
(f) Do the job set-up procedure as specified in the removal of the ELACs ( FIN 2CE1
and FIN 2CE2), refer to Ref. AMM Task 27-93-34-000-001.
(g) Do the job set-up procedure as specified in the removal of the FWC ( FIN 1WW2),
refer to Ref. AMM Task 31-53-34-000-001.
(h) Do the job set-up procedure as specified in the removal of the DMCs ( FIN 1WT2
and FIN 1WT3), refer to Ref. AMM Task 31-63-34-000-001.
(i) Do the job set-up procedure as specified in the removal of the ATC/
Mode S Transponders ( FIN 1SH1 and FIN 1SH2), refer to Ref. AMM Task
34-52-33-000-001.
(j) Do the job set-up procedure as specified in the removal of the TCAS ( FIN 1SG),
refer to Ref. AMM Task 34-43-34-000-001.
(k) If installed, do the job set-up procedure as specified in the removal of the DMU
( FIN 1TV), refer to Ref. AMM Task 31-36-34-000-001.
(l) Do the job set-up procedure as specified in the removal of the GPWC ( FIN 1WZ),
refer to Ref. AMM Task 34-48-34-000-001.
(m) Make sure that the external connector(s) is (are) not connected to the aircraft
receptacle(s) EXT PWR.
(n) Put the warning notices in position on the external power receptacle to tell
persons not to connect an external power source.
(o) Make sure that the EMER EXIT LT pushbutton switch on the Electrical Panel 25VU
is set to OFF.
(p) In the cockpit, on the Electrical Panel 35VU, release the BAT pushbutton
switches.
(q) Put a warning notice in position on the Electrical Panel 35VU to tell persons not
to operate the batteries.
(r) Put a warning notice in position on the Refuel/Defuel Electrical Panel 800VU to
tell persons not to operate the NORMAL BATTERY switch.
(s) Put a warning notice in position in the cockpit to tell persons not to start the
APU.
(t) Put a warning notice in position in the cockpit to tell persons not to start the ENG
1,2.
(u) Disconnect the battery connectors
1 For the job set-up, refer to the removal of the batteries, refer to Ref. AMM
Task 24-38-51-000-001.
Man-hours 10.00 h
Minimum Number of person 1
Elapsed Time 10.00 h
Referenced Information
Manuals/Drawings References/Sheets
Task 12-34-24-869-002
Task 21-31-34-000-001
Task 21-61-34-000-001
Task 22-66-34-000-002
Task 22-83-34-000-001
Task 24-38-51-000-001
Task 25-54-11-000-001
Task 27-93-34-000-001
Task 27-94-34-000-001
Task 31-36-34-000-001
AMM
Task 31-36-34-000-002
Task 31-53-34-000-001
Task 31-63-34-000-001
Task 34-36-31-000-001
Task 34-43-34-000-001
Task 34-48-34-000-001
Task 34-52-33-000-001
Task 36-11-34-000-001
Task 46-21-34-000-001
Task 52-41-00-010-002
Procedure
NOTE: For the basic Aircraft configuration, refer to AMM Chapter "Introduction -
Aircraft status for maintenance" in Manual Front Matter section.
(a) Make sure that the aircraft is electrically grounded, refer to Ref. AMM Task
12-34-24-869-002.
(b) Open the avionics compartment Door 812, refer to Ref. AMM Task
52-41-00-010-002.
(c) In the FWD cargo compartment, at Frame 24A, remove the Panel 131CW, Panel
131DW and Panel 132EW, refer to Ref. AMM Task 25-54-11-000-001.
(d) Do the job set-up procedure as specified in the removal of the FMGCs ( FIN 1CA1
and FIN 1CA2), refer to Ref. AMM Task 22-83-34-000-001.
(e) Do the job set-up procedure as specified in the removal of the FACs ( FIN 1CC1
and FIN 1CC2), refer to Ref. AMM Task 22-66-34-000-002.
(f) Do the job set-up procedure as specified in the removal of the SECs ( FIN 1CE1
and FIN 1CE2), refer to Ref. AMM Task 27-94-34-000-001.
(g) Do the job set-up procedure as specified in the removal of the ELACs ( FIN 2CE1
and FIN 2CE2), refer to Ref. AMM Task 27-93-34-000-001.
(h) Do the job set-up procedure as specified in the removal of the FWC ( FIN 1WW2),
refer to Ref. AMM Task 31-53-34-000-001.
(i) Do the job set-up procedure as specified in the removal of the DMCs ( FIN 1WT2
and FIN 1WT3), refer to Ref. AMM Task 31-63-34-000-001.
(j) Do the job set-up procedure as specified in the removal of the ATC/
Mode S Transponders ( FIN 1SH1 and FIN 1SH2), refer to Ref. AMM Task
34-52-33-000-001.
(k) Do the job set-up procedure as specified in the removal of the TCAS ( FIN 1SG),
refer to Ref. AMM Task 34-43-34-000-001.
(l) If installed, do the job set-up procedure as specified in the removal of the DMU
( FIN 1TV), refer to Ref. AMM Task 31-36-34-000-001.
(m) If installed, do the job set-up procedure as specified in the removal of the Flight
Data Interface and Management Unit (FDIMU) ( FIN 10TV), refer to Ref. AMM Task
31-36-34-000-002.
(n) Do the job set-up procedure as specified in the removal of the GPWC ( FIN 1WZ),
refer to Ref. AMM Task 34-48-34-000-001.
(o) Do the job set-up procedure as specified in the removal of the ATSU ( FIN 1TX1),
refer to Ref. AMM Task 46-21-34-000-001.
(p) Do the job set-up procedure as specified in the removal of the MMRs ( FIN 40RT1
and FIN 40RT2), refer to Ref. AMM Task 34-36-31-000-001.
(q) Do the job set-up procedure as specified in the removal of the BMCs ( FIN 1HA1
and FIN 1HA2), refer to Ref. AMM Task 36-11-34-000-001.
(r) Do the job set-up procedure as specified in the removal of the CPCs ( FIN 11HL
and FIN 12HL), refer to Ref. AMM Task 21-31-34-000-001.
(s) Do the job set-up procedure as specified in the removal of the PCs ( FIN 7HH and
FIN 27HH), refer to Ref. AMM Task 21-61-34-000-001.
(t) Make sure that the external connector(s) is (are) not connected to the aircraft
receptacle(s) EXT PWR.
(u) Put the warning notices in position on the external power receptacle to tell
persons not to connect an external power source.
(v) Make sure that the EMER EXIT LT pushbutton switch on the Electrical Panel 25VU
is set to OFF.
(w) In the cockpit, on the Electrical Panel 35VU, release the BAT pushbutton
switches.
(x) Put a warning notice in position on the Electrical Panel 35VU to tell persons not
to operate the batteries.
(y) Put a warning notice in position on the Refuel/Defuel Electrical Panel 800VU to
tell persons not to operate the NORMAL BATTERY switch.
(z) Put a warning notice in position in the cockpit to tell persons not to start the
APU.
(aa) Put a warning notice in position in the cockpit to tell persons not to start the ENG
1,2.
Man-hours 47.00 h
Minimum Number of person 1
Elapsed Time 47.00 h
Material necessary to do the job
Part kit 341620A01R01
ITEM PART No. QTY (UM) KEYWORD DRAWING SEE NOTES
D9000095460995 1 BUNDLE
NSA935401-05 150 TIE
NSA935401-08 150 TIE
NSA935401-13 150 TIE
NSA937901E0 1 LABEL
NSA937901E1 4 LABEL
NSA937901E2 1 LABEL
NSA937901E3 5 LABEL
NSA937901E4 1 LABEL
NSA937901E5 1 LABEL
NSA937901E6 1 LABEL
NSA937901E7 1 LABEL
NSA937901E9 1 LABEL
NSA937901FM 4 MODULE
NSA937901MA2205 4 MODULE
NSA937901MA2206 4 MODULE
NSA937901S 6 CLAMP
Manuals/Drawings References/Sheets
Task 22-66-34-000-002
Task 22-66-34-400-002
Task 22-83-34-000-001
Task 22-83-34-400-001
Task 27-93-34-000-001
Task 27-93-34-400-001
Task 27-94-34-000-001
Task 27-94-34-400-001
Task 31-36-34-000-001
Task 31-36-34-400-001
AMM
Task 31-53-34-000-001
Task 31-53-34-400-001
Task 31-63-34-000-001
Task 31-63-34-400-001
Task 34-43-34-000-001
Task 34-43-34-400-001
Task 34-48-34-000-001
Task 34-48-34-400-001
Task 34-52-33-000-001
Task 34-52-33-400-001
20-33-00
20-33-44
ESPM
20-52-21
20-56-51
Procedure
(a) Standard Practices:
1 For the general installation of electrical wire harnesses, refer to Ref. ESPM
20-33-00.
2 For the cable tie application and tooling, refer to Ref. ESPM 20-33-44 and
Ref. ESPM 20-56-51.
3 Tag all the parts you must remove and retain to make the subsequent
installation easier.
4 Put all the retained hardware in identified plastic bags and attach the bags
to the related unit.
5 To install new wires, cut them to the necessary length, attach the terminals
and connect them.
(b) Remove and retain the FMGCs ( FIN 1CA1 and FIN 1CA2), refer to Ref. AMM Task
22-83-34-000-001.
(c) Remove and retain the FACs ( FIN 1CC1 and FIN 1CC2), refer to Ref. AMM Task
22-66-34-000-002.
(d) Remove and retain the SECs ( FIN 1CE1 and FIN 1CE2), refer to Ref. AMM Task
27-94-34-000-001.
(e) Remove and retain the ELACs ( FIN 2CE1 and FIN 2CE2), refer to Ref. AMM Task
27-93-34-000-001.
(f) Remove and retain the FWCs ( FIN 1WW1 and FIN 1WW2), refer to Ref. AMM Task
31-53-34-000-001.
(g) Remove and retain the DMCs ( FIN 1WT2 and FIN 1WT3), refer to Ref. AMM Task
31-63-34-000-001.
(h) Remove and retain the ATC/Mode S Transponders ( FIN 1SH1 and FIN 1SH2), refer
to Ref. AMM Task 34-52-33-000-001.
(i) Remove and retain the TCAS ( FIN 1SG), refer to Ref. AMM Task
34-43-34-000-001.
(j) Remove and retain the DMU ( FIN 1TV), refer to Ref. AMM Task
31-36-34-000-001.
(k) Remove and retain the GPWC ( FIN 1WZ), refer to Ref. AMM Task
34-48-34-000-001.
(l) Modify the equipment in the aft electronics rack Electrical Panel 80VU
Refer to Ref. Fig. Location of the Terminal Blocks in the Aft Electronics Rack 80VU
1 Modify the terminal block FIN 1813VT in the shelf Electrical Panel 81VU
a Install at position 30:
1 CLAMP-END NSA937901S
b Install at position 31:
FIN 1813VT31
1 MODULE NSA937901MA2206
1 CLAMP-END NSA937901S
2 Modify the terminal block FIN 1822VT in the shelf Electrical Panel 82VU
a Loosen the end clamps at each end of the terminal block.
b Install at position 38:
1 MODULE-FALSE NSA937901FM
c Install at position 39:
FIN 1822VT39
1 MODULE NSA937901MA2206
1 MODULE-FALSE NSA937901FM
c Install at position 10:
FIN 1831VT10
1 MODULE NSA937901MA2205
FIN 1840VT12
1 MODULE NSA937901MA2205
1 CLAMP-END NSA937901S
b Install at position 31:
FIN 1853VT31
1 MODULE NSA937901MA2206
1 CLAMP-END NSA937901S
6 Modify the terminal block FIN 1860VT in the shelf Electrical Panel 86VU
a Loosen the end clamps at each end of the terminal block.
b Remove from position 29:
FIN 1860VT29
1 MODULE NSA937901MA2205 Discard
c Install at position 29:
1 MODULE-FALSE NSA937901FM
d Install at position 35:
1 MODULE-FALSE NSA937901FM
FIN 1860VT36
1 MODULE NSA937901MA2205
FIN 1860VT37
1 MODULE NSA937901MA2205
1 CLAMP-END NSA937901S
b Install at position 54:
FIN 1862VT54
1 MODULE NSA937901MA2206
1 CLAMP-END NSA937901S
(m) Modify the wiring in the aft electronics rack Electrical Panel 80VU
Refer to Ref. ESPM 20-33-00
1 Remove the wire(s) as shown on this(these) wiring diagram(s) and the
related hook-up chart(s):
- Ref. Fig. WA and Ref. Fig. HA
- Ref. Fig. WB and Ref. Fig. HB
- Ref. Fig. WC and Ref. Fig. HC
- Ref. Fig. WD and Ref. Fig. HD
- Ref. Fig. WG and Ref. Fig. HG
- Ref. Fig. WJ and Ref. Fig. HJ
- Ref. Fig. WK and Ref. Fig. HK.
2 Install the wire(s) as shown on this(these) wiring diagram(s) and the
related hook-up chart(s):
- Ref. Fig. WA and Ref. Fig. HA
- Ref. Fig. WB and Ref. Fig. HB
- Ref. Fig. WC and Ref. Fig. HC
- Ref. Fig. WD and Ref. Fig. HD
REV 00 Dec 21/15 A320-34-1620
REV 06 Jul 22/19 Page 36
A318/A319/A320/A321
SERVICE BULLETIN
1 BUNDLE D9000095460895
1 BUNDLE D9000095460995
3 Attach the wires with:
Refer to Ref. ESPM 20-33-44 and Ref. ESPM 20-56-51
CONF 001
824
A
FR24
Z120
FR1
1822VT
1813VT
1840VT
1860VT
1862VT
1831VT 1853VT
A
80VU
ICN-A320-A-34XX1620-A-FAPE3-00MEY-A-002-01
CONF 001
0338 S 17
BEFORE
3457-0071
8
AE
F.R.
7B B U
3443-7065 V
7A R
P B 16
X 3457-7077
1SG R 13
CMPTR D
TCAS Y 83VC A
82VU 127
128 E
AB
F AB
4K B
2286-7103 B 4K
4J R G 2269-7071
R 4J
1CA1 L
FMGC-1 1CC1
83VU FAC-1
127 M 83VU
127
N
AD
AA
4G B S
2792-7122 B S 9K
4F R S 2792-7152
T R S 9J
50 A
AA AD
P
2B B S B S 9B
M 2792-7123 B 2792-7150
2A R S R S 9A
F
F.R. - F.R. S
B 43 2CE1 7S 7S 1CE1
3436-7182 F.R. ELAC-1 SEC-1
S R 42 83VU H 83VU
127 127
F.R. 79VC A
127 C
J
F.R.
14 B S J
F.R. 7079
13 R S H B S
R
A 151VC 7230
127 F.R. -
A R S K
1851VT 1831VT
127 127
85VU 83VU
0825 S
DELETED WIRE F.R. FOR REFERENCE EXISTING WIRE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 3411
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK26 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 1S
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-34XX1620-A-FAPE3-00MG1-A-002-01
CONF 001
0338 S
AFTER
8 AA
X B 2B
AE 3452-7095
R 2A
7B B U
3443-7065 V
7A R 1SH1
P XPDR
Y ATC-1
1SG 81VU
CMPTR D 127
TCAS
82VU
128 E B 16
3457-7077
AB R 13
F
4K B
3457-0071
2286-7103
4J R G F.R.
1CA1 L
FMGC-1
83VU
127 M 17
83VC A
N 127
AD 10
AB
4G B S X
2792-7122 B 4K
4F R S V 2269-7071
U R 4J
50 D 1CC1
AA FAC-1
P
2B B S Y 83VU
M 2792-7123 E 127
2A R S
F
F.R. - F.R. P
B 43 2CE1 7S AA
3436-7182 F.R. ELAC-1
S R 42 83VU G B S 9K
127 2792-7152
F.R. 79VC A R S 9J
127 F
J
F.R. AD
14 B S L
F.R. 7079 B S 9B
13 R S H B S 2792-7150
N R S 9A
A 151VC 7230
127 F.R. -
A R S M 1CE1
7S SEC-1
1851VT 1831VT 83VU
127 127 127
85VU 83VU
0825 S
NEW WIRE F.R. FOR REFERENCE EXISTING WIRE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 3411
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK26 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 1S
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-34XX1620-A-FAPE3-00MG2-A-002-01
CONF 001
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 83VU 1831VT SH 2269G7071 1S TK26 83VU 1CC1-AB SH D
2 83VU 1831VT 8E 2269-7071 B 1S TK26 83VU 1CC1-AB 4K D
3 83VU 1CC1-AB 4J 2269-7071 R 1S TK26 83VU 1831VT 8B D
4 83VU 1831VT SH 2286G7103 1S TK26 83VU 1CA1-AB SH D
5 83VU 1831VT 8D 2286-7103 B 1S TK26 83VU 1CA1-AB 4K D
6 83VU 1CA1-AB 4J 2286-7103 R 1S TK26 83VU 1831VT 8A D
7 83VU 1831VT SH 2792G7122 7S TK26 83VU 2CE1-AD SH D
8 83VU 1831VT 8G 2792S7122 B 7S TK26 83VU 2CE1-AD 4G D
9 83VU 1831VT 8H 2792S7122 R 7S TK26 83VU 2CE1-AD 4F D
10 83VU 1831VT SH 2792G7123 7S TK26 83VU 2CE1-AA SH D
11 83VU 1831VT 8F 2792S7123 B 7S TK26 83VU 2CE1-AA 2B D
12 83VU 1831VT 8C 2792S7123 R 7S TK26 83VU 2CE1-AA 2A D
13 83VU 1831VT SH 2792G7150 7S TK26 83VU 1CE1-AD SH D
14 83VU 1831VT 8N 2792S7150 B 7S TK26 83VU 1CE1-AD 9B D
15 83VU 1831VT 8R 2792S7150 R 7S TK26 83VU 1CE1-AD 9A D
16 83VU 1831VT SH 2792G7152 7S TK26 83VU 1CE1-AA SH D
17 83VU 1831VT 8L 2792S7152 B 7S TK26 83VU 1CE1-AA 9K D
18 83VU 1831VT 8J 2792S7152 R 7S TK26 83VU 1CE1-AA 9J D
19
20
21
22
23
24
25
D = DELETED WIRE
SH = SHIELD
S = SAFETY WIRE
CONF 001
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 83VU 2792G7152 W.F. 3411S0338 7S CF24 83VU 2269G7071 W.F. D
2 83VU 2269G7071 W.F. 3411S0338 7S CF24 83VU 3457G7077 W.F. D
3 83VU 3457G7077 W.F. 3411S0338 7S CF24 83VU 3443G7065 W.F. D
4 83VU 3443G7065 W.F. 3411S0338 7S CF24 83VU 2286G7103 W.F. D
5 83VU 2286G7103 W.F. 3411S0338 7S CF24 83VU 2792G7122 W.F. D
6 83VU 2792G7122 W.F. 3411S0338 7S CF24 83VU 2792G7123 W.F. D
7 83VU 2792G7123 W.F. 3411S0338 7S CF24 83VU 3411G7230 W.F. D
8 83VU 3411G7230 W.F. 3411S0338 7S CF24 83VU 2792G7150 W.F. D
9 83VU 2792G7150 W.F. 3411S0338 7S CF24 83VU 2792G7152 W.F. D
10 83VU 1831VT SH 3411G7230 1S TK26 85VU 1851VT SH D
11 83VU 1831VT 8M 3411S7230 B 1S TK26 85VU 1851VT 50F D
12 83VU 1831VT 8K 3411S7230 R 1S TK26 85VU 1851VT 50A D
13 83VU 1831VT SH 3443G7065 1S TK26 82VU 1SG-AE SH D
14 83VU 1831VT 8U 3443-7065 B 1S TK26 82VU 1SG-AE 7B D
15 83VU 1831VT 8T 3443-7065 R 1S TK26 82VU 1SG-AE 7A D
16 83VU 1831VT SH 3457G7077 1S TK26 127 83VC SH D
17 83VU 1831VT 8P 3457-7077 B 1S TK26 127 83VC 16 D
18 127 83VC 13 3457-7077 R 1S TK26 83VU 1831VT 8S D
19 127 3436G7182 W.F. 3411S0825 1S CF24 85VU 3411G7230 W.F. D
20 85VU 3411G7230 W.F. 3411S0825 1S CF24 127 3411G7079 W.F. D
21 127 3457G7077 W.F. 3457-0071 1S CF24 127 83VC 17 D
22
23
24
25
D = DELETED WIRE S = SAFETY WIRE
SH = SHIELD
W.F. = WIRE FERRULE
CONF 001
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 83VU 1831VT SH E0718-02-30 2269G7071 1S TK26 2000 80 83VU 1CC1-AB SH E0718-02-30 (a) A
2 83VU 1831VT 8E EN3155-016M2222 2269-7071 B 1S TK26 2000 80 83VU 1CC1-AB 4K E0170FA2200 (a) A
3 83VU 1CC1-AB 4J E0170FA2200 2269-7071 R 1S TK26 2000 80 83VU 1831VT 10E EN3155-016M2222 (a) A
4 83VU 1831VT SH E0718-02-30 2286G7103 1S TK26 1500 60 83VU 1CA1-AB SH E0718-02-30 (a) A
5 83VU 1831VT 8D EN3155-016M2222 2286-7103 B 1S TK26 1500 60 83VU 1CA1-AB 4K E0170FA2200 (a) A
6 83VU 1CA1-AB 4J E0170FA2200 2286-7103 R 1S TK26 1500 60 83VU 1831VT 10D EN3155-016M2222 (a) A
7 83VU 1831VT SH E0718-02-30 2792G7122 7S TK26 1500 60 83VU 2CE1-AD SH E0718-02-30 (a) A
8 83VU 1831VT 8G EN3155-016M2222 2792S7122 B 7S TK26 1500 60 83VU 2CE1-AD 4G E0170FA2200 (a) A
9 83VU 1831VT 10G EN3155-016M2222 2792S7122 R 7S TK26 1500 60 83VU 2CE1-AD 4F E0170FA2200 (a) A
10 83VU 1831VT SH E0718-02-30 2792G7123 7S TK26 1500 60 83VU 2CE1-AA SH E0718-02-30 (a) A
11 83VU 1831VT 8F EN3155-016M2222 2792S7123 B 7S TK26 1500 60 83VU 2CE1-AA 2B E0170FA2200 (a) A
12 83VU 1831VT 10F EN3155-016M2222 2792S7123 R 7S TK26 1500 60 83VU 2CE1-AA 2A E0170FA2200 (a) A
13 83VU 1831VT SH E0718-02-30 2792G7150 7S TK26 1000 40 83VU 1CE1-AD SH E0718-02-30 (a) A
14 83VU 1831VT 8N EN3155-016M2222 2792S7150 B 7S TK26 1000 40 83VU 1CE1-AD 9B E0170FA2200 (a) A
15 83VU 1831VT 10N EN3155-016M2222 2792S7150 R 7S TK26 1000 40 83VU 1CE1-AD 9A E0170FA2200 (a) A
16 83VU 1831VT SH E0718-02-30 2792G7152 7S TK26 1000 40 83VU 1CE1-AA SH E0718-02-30 (a) A
17 83VU 1831VT 8L EN3155-016M2222 2792S7152 B 7S TK26 1000 40 83VU 1CE1-AA 9K E0170FA2200 (a) A
18 83VU 1831VT 10L EN3155-016M2222 2792S7152 R 7S TK26 1000 40 83VU 1CE1-AA 9J E0170FA2200 (a) A
19
20
21
22
23
24
25
(a) = BUNDLE D9000095460895 S = SAFETY WIRE
A = ADDED WIRE
SH = SHIELD
CONF 001
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 83VU 2269G7071 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 3457G7077 W.F. E0160-1-0H (a) A
2 83VU 3457G7077 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 3452G7095 W.F. E0160-1-0H (a) A
3 83VU 3452G7095 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 3443G7065 W.F. E0160-1-0H (a) A
4 83VU 3443G7065 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 2286G7103 W.F. E0160-1-0H (a) A
5 83VU 2286G7103 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 2792G7122 W.F. E0160-1-0H (a) A
6 83VU 2792G7122 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 2792G7123 W.F. E0160-1-0H (a) A
7 83VU 2792G7123 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 3411G7230 W.F. E0160-1-0H (a) A
8 83VU 3411G7230 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 2792G7150 W.F. E0160-1-0H (a) A
9 83VU 2792G7150 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 2792G7152 W.F. E0160-1-0H (a) A
10 83VU 2792G7152 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 2269G7071 W.F. E0160-1-0H (a) A
11 83VU 1831VT SH E0718-02-30 3411G7230 1S TK26 3500 140 85VU 1851VT SH E0718-02-30 (a) A
12 83VU 1831VT 8M EN3155-016M2222 3411S7230 B 1S TK26 3500 140 85VU 1851VT 50F EN3155-016M2222 (a) A
13 83VU 1831VT 10M EN3155-016M2222 3411S7230 R 1S TK26 3500 140 85VU 1851VT 50A EN3155-016M2222 (a) A
14 83VU 1831VT SH E0718-02-30 3443G7065 1S TK26 4000 160 82VU 1SG-AE SH E0718-02-30 (a) A
15 83VU 1831VT 8U EN3155-016M2222 3443-7065 B 1S TK26 4000 160 82VU 1SG-AE 7B E0170FA2200 (a) A
16 83VU 1831VT 10U EN3155-016M2222 3443-7065 R 1S TK26 4000 160 82VU 1SG-AE 7A E0170FA2200 (a) A
17 83VU 1831VT SH E0718-02-30 3452G7095 1S TK26 3500 140 81VU 1SH1-AA SH E0718-02-30 (a) A
18 83VU 1831VT 8X EN3155-016M2222 3452-7095 B 1S TK26 3500 140 81VU 1SH1-AA 2B E0170FA2200 (a) A
19 81VU 1SH1-AA 2A E0170FA2200 3452-7095 R 1S TK26 3500 140 83VU 1831VT 10X EN3155-016M2222 (a) A
20 83VU 1831VT SH E0718-02-30 3457G7077 1S TK26 3500 140 127 83VC SH E0718-02-30 (a) A
21 83VU 1831VT 8P EN3155-016M2222 3457-7077 B 1S TK26 3500 140 127 83VC 16 EN3155-008M2222 (a) A
22 127 83VC 13 EN3155-008M2222 3457-7077 R 1S TK26 3500 140 83VU 1831VT 10P EN3155-016M2222 (a) A
23 127 3436G7182 W.F. E0160-1-0H 3411S0825 1S CF24 1000 40 85VU 3411G7230 W.F. E0160-1-0H (a) A
24 85VU 3411G7230 W.F. E0160-1-0H 3411S0825 1S CF24 1000 40 127 3411G7079 W.F. E0160-1-0H (a) A
25 127 3457G7077 W.F. E0160-1-0H 3457-0071 1S CF24 500 20 127 83VC 17 EN3155-008M2222 (a) A
(a) = BUNDLE D9000095460895 W.F. = WIRE FERRULE
A = ADDED WIRE S = SAFETY WIRE
SH = SHIELD
CONF 001
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 127 151VC SH E0718-02-30 3411G7079 1S TK26 85VU 1851VT SH E0718-02-30 F.R.
2 127 151VC 14 3411S7079 B 1S TK26 85VU 1851VT 50M F.R.
3 127 151VC 13 3411S7079 R 1S TK26 85VU 1851VT 50H F.R.
4 127 79VC SH E0718-02-30 3436G7182 1S TK26 85VU 1851VT SH E0718-02-30 F.R.
5 127 79VC 43 3436-7182 B 1S TK26 85VU 1851VT 50P F.R.
6 85VU 1851VT 50S 3436-7182 R 1S TK26 127 79VC 42 F.R.
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
F.R. = FOR REFERENCE
SH = SHIELD
S = SAFETY WIRE
CONF 001
BEFORE
0820 S
AB 10
4K B M
2269-7069 V
4J R
E
X
1CC2
FAC-2 F
84VU Y
128
AB
P
AD B 4K
2286-7107
5G B S G R 4J
2792-7116
5F R S
D 1CA2
FMGC-2
2CE2 8S 84VU
ELAC-2 N 128
84VU
128
U
44
L
3436-0337
8S
AD
B S 9B
2792-7142
F.R. B R S 9A
43 B AA
3436-7172 K
42 R B S 9K
2792-7144
A 36VC A R S 9J
128
C 1CE2
7 0443 S SEC-2
F.R. 6 B S 84VU
7142 T 128
5 R S
A 42VC H
128 S 36
0458
J
R 7090 B
F.R.
TK24 R F.R.
P R
B S 35
A 198VC 7091
188VU S R S 34
128
1840VT 152VC A
128 128
84VU
DELETED WIRE F.R. FOR REFERENCE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 3411
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK26 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 2S
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-34XX1620-A-FAPE3-00MG5-A-002-01
CONF 001
AFTER
0820 S
10 AA
X B 2B
AB V 3452-7090
R 2A
4K B M
2269-7069 Y
4J R 1SH2
E XPDR
ATC-2
1CC2 FAC-2 82VU
84VU 128 F 128
AD 8S AB
P
5G B S B 4K
2792-7116 2286-7107
5F R S G R 4J
3436-0337
U
L
F.R. 8S
12
AD
X
43 B B S 9B
3436-7172 2792-7142
42 R E R S 9A
A 36VC
128 AA
F
B S 9K
2792-7144
7 0443 S D R S 9J
6 B S V
F.R. 7142 M 1CE2
5 R S SEC-2
Y 84VU
A 42VC U 128
128
R B N
F.R. 7090
TK24 S 36
P R
0458
P
A 198VC
128 188VU
G
B S 35
7091
L R S 34
1840VT 152VC A
128 128
84VU
NEW WIRE F.R. FOR REFERENCE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 3411
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK26 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 2S
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-34XX1620-A-FAPE3-00MG6-A-002-01
CONF 001
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 84VU 1840VT SH 2269G7069 2S TK26 84VU 1CC2-AB SH D
2 84VU 1840VT 10M 2269-7069 B 2S TK26 84VU 1CC2-AB 4K D
3 84VU 1840VT 10C 2269-7069 R 2S TK26 84VU 1CC2-AB 4J D
4 84VU 1840VT SH 2286G7107 2S TK26 84VU 1CA2-AB SH D
5 84VU 1840VT 10F 2286-7107 B 2S TK26 84VU 1CA2-AB 4K D
6 84VU 1840VT 10K 2286-7107 R 2S TK26 84VU 1CA2-AB 4J D
7 84VU 1840VT SH 2792G7116 8S TK26 84VU 2CE2-AD SH D
8 84VU 1840VT 10P 2792S7116 B 8S TK26 84VU 2CE2-AD 5G D
9 84VU 1840VT 10J 2792S7116 R 8S TK26 84VU 2CE2-AD 5F D
10 84VU 1840VT SH 2792G7142 8S TK26 84VU 1CE2-AD SH D
11 84VU 1840VT 10E 2792S7142 B 8S TK26 84VU 1CE2-AD 9B D
12 84VU 1840VT 10B 2792S7142 R 8S TK26 84VU 1CE2-AD 9A D
13 84VU 1840VT SH 2792G7144 8S TK26 84VU 1CE2-AA SH D
14 84VU 1840VT 10D 2792S7144 B 8S TK26 84VU 1CE2-AA 9K D
15 84VU 1840VT 10A 2792S7144 R 8S TK26 84VU 1CE2-AA 9J D
16 84VU 3411G7142 W.F. 3411S0820 2S CF24 188VU 3411G7090 W.F. D
17 188VU 3411G7090 W.F. 3411S0820 2S CF24 128 3411G7091 W.F. D
18 128 3411G7091 W.F. 3411S0820 2S CF24 84VU 2792G7144 W.F. D
19 84VU 2792G7144 W.F. 3411S0820 2S CF24 84VU 2792G7142 W.F. D
20 84VU 2792G7142 W.F. 3411S0820 2S CF24 84VU 2286G7107 W.F. D
21 84VU 2286G7107 W.F. 3411S0820 2S CF24 84VU 2269G7069 W.F. D
22 84VU 2269G7069 W.F. 3411S0820 2S CF24 84VU 2792G7116 W.F. D
23 84VU 2792G7116 W.F. 3411S0820 2S CF24 84VU 3436G7172 W.F. D
24 84VU 3436G7172 W.F. 3411S0820 2S CF24 84VU 3411G7142 W.F. D
25
D = DELETED WIRE S = SAFETY WIRE
SH = SHIELD
W.F. = WIRE FERRULE
CONF 001
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 84VU 1840VT SH 3411G7090 2S TK24 188VU 198VC SH D
2 84VU 1840VT 10G 3411-7090 B 2S TK24 188VU 198VC R D
3 84VU 1840VT 10R 3411-7090 R 2S TK24 188VU 198VC P D
4 84VU 1840VT SH 3411G7091 2S TK26 128 152VC SH D
5 84VU 1840VT 10L 3411S7091 B 2S TK26 128 152VC 35 D
6 84VU 1840VT 10S 3411S7091 R 2S TK26 128 152VC 34 D
7 84VU 1840VT SH 3411G7142 2S TK26 128 42VC SH D
8 84VU 1840VT 10N 3411S7142 B 2S TK26 128 42VC 6 D
9 84VU 1840VT 10H 3411S7142 R 2S TK26 128 42VC 5 D
10 84VU 1840VT SH 3436G7172 2S TK26 128 36VC SH D
11 84VU 1840VT 10U 3436-7172 B 2S TK26 128 36VC 43 D
12 84VU 1840VT 10T 3436-7172 R 2S TK26 128 36VC 42 D
13 84VU 3411G7091 W.F. 3411S0458 2S CF24 128 152VC 36 D
14 128 3411G7142 W.F. 3411S0443 2S CF24 128 42VC 7 D
15 128 3436G7172 W.F. 3436-0337 2S CF24 128 36VC 44 D
16
17
18
19
20
21
22
23
24
25
D = DELETED WIRE S = SAFETY WIRE
SH = SHIELD
W.F. = WIRE FERRULE
CONF 001
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 84VU 1840VT SH E0718-02-30 2269G7069 2S TK26 1000 40 84VU 1CC2-AB SH E0718-02-30 (a) A
2 84VU 1840VT 10M EN3155-016M2222 2269-7069 B 2S TK26 1000 40 84VU 1CC2-AB 4K E0170FA2200 (a) A
3 84VU 1840VT 12M EN3155-016M2222 2269-7069 R 2S TK26 1000 40 84VU 1CC2-AB 4J E0170FA2200 (a) A
4 84VU 1840VT SH E0718-02-30 2286G7107 2S TK26 1500 60 84VU 1CA2-AB SH E0718-02-30 (a) A
5 84VU 1840VT 10F EN3155-016M2222 2286-7107 B 2S TK26 1500 60 84VU 1CA2-AB 4K E0170FA2200 (a) A
6 84VU 1840VT 12F EN3155-016M2222 2286-7107 R 2S TK26 1500 60 84VU 1CA2-AB 4J E0170FA2200 (a) A
7 84VU 1840VT SH E0718-02-30 2792G7116 8S TK26 2500 100 84VU 2CE2-AD SH E0718-02-30 (a) A
8 84VU 1840VT 10P EN3155-016M2222 2792S7116 B 8S TK26 2500 100 84VU 2CE2-AD 5G E0170FA2200 (a) A
9 84VU 1840VT 12P EN3155-016M2222 2792S7116 R 8S TK26 2500 100 84VU 2CE2-AD 5F E0170FA2200 (a) A
10 84VU 1840VT SH E0718-02-30 2792G7142 8S TK26 2000 80 84VU 1CE2-AD SH E0718-02-30 (a) A
11 84VU 1840VT 10E EN3155-016M2222 2792S7142 B 8S TK26 2000 80 84VU 1CE2-AD 9B E0170FA2200 (a) A
12 84VU 1840VT 12E EN3155-016M2222 2792S7142 R 8S TK26 2000 80 84VU 1CE2-AD 9A E0170FA2200 (a) A
13 84VU 1840VT SH E0718-02-30 2792G7144 8S TK26 2000 80 84VU 1CE2-AA SH E0718-02-30 (a) A
14 84VU 1840VT 10D EN3155-016M2222 2792S7144 B 8S TK26 2000 80 84VU 1CE2-AA 9K E0170FA2200 (a) A
15 84VU 1840VT 12D EN3155-016M2222 2792S7144 R 8S TK26 2000 80 84VU 1CE2-AA 9J E0170FA2200 (a) A
16 84VU 3411G7142 W.F. E0160-1-0H 3411S0820 2S CF24 5000 200 84VU 3411G7090 W.F. E0160-1-0H (a) A
17 84VU 3411G7090 W.F. E0160-1-0H 3411S0820 2S CF24 5000 200 128 3411G7091 W.F. E0160-1-0H (a) A
18 128 3411G7091 W.F. E0160-1-0H 3411S0820 2S CF24 5000 200 84VU 2792G7144 W.F. E0160-1-0H (a) A
19 84VU 2792G7144 W.F. E0160-1-0H 3411S0820 2S CF24 5000 200 84VU 2792G7142 W.F. E0160-1-0H (a) A
20 84VU 2792G7142 W.F. E0160-1-0H 3411S0820 2S CF24 5000 200 84VU 2286G7107 W.F. E0160-1-0H (a) A
21 84VU 2286G7107 W.F. E0160-1-0H 3411S0820 2S CF24 5000 200 84VU 3452G7090 W.F. E0160-1-0H (a) A
22 84VU 3452G7090 W.F. E0160-1-0H 3411S0820 2S CF24 5000 200 84VU 2269G7069 W.F. E0160-1-0H (a) A
23 84VU 2269G7069 W.F. E0160-1-0H 3411S0820 2S CF24 5000 200 84VU 2792G7116 W.F. E0160-1-0H (a) A
24 84VU 2792G7116 W.F. E0160-1-0H 3411S0820 2S CF24 5000 200 84VU 3436G7172 W.F. E0160-1-0H (a) A
25 84VU 3436G7172 W.F. E0160-1-0H 3411S0820 2S CF24 5000 200 84VU 3411G7142 W.F. E0160-1-0H (a) A
(a) = BUNDLE D9000095460895 W.F. = WIRE FERRULE
A = ADDED WIRE S = SAFETY WIRE
SH = SHIELD
CONF 001
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 84VU 1840VT SH E0718-02-30 3411G7090 2S TK24 6000 240 188VU 198VC SH E0718-02-30 (a) A
2 84VU 1840VT 10G EN3155-016M2222 3411-7090 B 2S TK24 6000 240 188VU 198VC R EN3155-019F2018 (a) A
3 84VU 1840VT 12G EN3155-016M2222 3411-7090 R 2S TK24 6000 240 188VU 198VC P EN3155-019F2018 (a) A
4 84VU 1840VT SH E0718-02-30 3411G7091 2S TK26 4000 160 128 152VC SH E0718-02-30 (a) A
5 84VU 1840VT 10L EN3155-016M2222 3411S7091 B 2S TK26 4000 160 128 152VC 35 EN3155-008M2222 (a) A
6 84VU 1840VT 12L EN3155-016M2222 3411S7091 R 2S TK26 4000 160 128 152VC 34 EN3155-008M2222 (a) A
7 84VU 1840VT SH E0718-02-30 3411G7142 2S TK26 2000 80 128 42VC SH E0718-02-30 (a) A
8 84VU 1840VT 10N EN3155-016M2222 3411S7142 B 2S TK26 2000 80 128 42VC 6 EN3155-008M2222 (a) A
9 84VU 1840VT 12N EN3155-016M2222 3411S7142 R 2S TK26 2000 80 128 42VC 5 EN3155-008M2222 (a) A
10 84VU 1840VT SH E0718-02-30 3436G7172 2S TK26 2000 80 128 36VC SH E0718-02-30 (a) A
11 84VU 1840VT 10U EN3155-016M2222 3436-7172 B 2S TK26 2000 80 128 36VC 43 EN3155-008M2222 (a) A
12 84VU 1840VT 12U EN3155-016M2222 3436-7172 R 2S TK26 2000 80 128 36VC 42 EN3155-008M2222 (a) A
13 84VU 1840VT SH E0718-02-30 3452G7090 2S TK26 2500 100 82VU 1SH2-AA SH E0718-02-30 (a) A
14 84VU 1840VT 10X EN3155-016M2222 3452-7090 B 2S TK26 2500 100 82VU 1SH2-AA 2B E0170FA2200 (a) A
15 82VU 1SH2-AA 2A E0170FA2200 3452-7090 R 2S TK26 2500 100 84VU 1840VT 12X EN3155-016M2222 (a) A
16 84VU 3411G7091 W.F. E0160-1-0H 3411S0458 2S CF24 500 20 128 152VC 36 EN3155-008M2222 (a) A
17 128 3411G7142 W.F. E0160-1-0H 3411S0443 2S CF24 500 20 128 42VC 7 EN3155-008M2222 (a) A
18 128 3436G7172 W.F. E0160-1-0H 3436-0337 2S CF24 500 20 128 36VC 44 EN3155-008M2222 (a) A
19
20
21
22
23
24
25
(a) = BUNDLE D9000095460895 W.F. = WIRE FERRULE
A = ADDED WIRE S = SAFETY WIRE
SH = SHIELD
CONF 001
BEFORE
29
AE
8A R B
3152-7145
8B B
S
1WW2 FWC-2
86VU
128 A
AA
K R 2F
3161-7167
B 2G
R
1WT3
C DMC-3
85VU
127
T
AA
J R 2F
13 3161-7170
B 2G
3411-0301
V
1WT2
E DMC-2
F.R. 86VU
128
P
M
14 R
3411-7171
20 B Y
L AA
A 152VC
128 R 9C
3448-7068
X B 9D
15 R
7194
16 B G 1WZ
GPWC
17 0349 88VU
D 128
F.R. AB
U
R 5J
13 0450 7195
F B 5K
11 R
7233
12 B N 1CA2
FMGC-2
A 36VC 1860VT 84VU
128 128 128
86VU
0354
DELETED WIRE F.R. FOR REFERENCE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 2286
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK26 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 2S
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-34XX1620-A-FAPE3-00MG9-A-002-01
CONF 001
AFTER
36 AB
D R 3F
AE 3452-7081
B 3G
8A R P
3152-7145 AA
8B B
E R 7A
3452-7082
1WW2 FWC-2 B 7B
86VU V
128
X 1SH2
XPDR
ATC-2
L 82VU 128
AA
F R 2F
Y 3161-7167
B 2G
N
1WT3
M DMC-3
85VU
127
U
AA
G R 2F
13 3161-7170
37 B 2G
D
3411-0301
1WT2
E DMC-2
F.R. 86VU
128
P
14 R
3411-7171 F
20 B
A 152VC AA
G
128 R 9C
3448-7068
U B 9D
15 R
7194 Y
16 B L 1WZ
GPWC
17 0349 88VU
X 128
AB
F.R. V
R 5J
13 0450 7195
M B 5K
11 R
7233
12 B N 1CA2
FMGC-2
A 36VC 1860VT 84VU
128 128 86VU 128
0354
NEW WIRE F.R. FOR REFERENCE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 2286
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK26 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 2S
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-34XX1620-A-FAPE3-00MGA-A-002-01
CONF 001
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 86VU 1860VT SH 3152G7145 2S TK26 86VU 1WW2-AE SH D
2 86VU 1860VT 29E 3152-7145 B 2S TK26 86VU 1WW2-AE 8B D
3 86VU 1860VT 29B 3152-7145 R 2S TK26 86VU 1WW2-AE 8A D
4 86VU 1860VT SH 3161G7170 2S TK26 86VU 1WT2-AA SH D
5 86VU 1860VT 29L 3161-7170 B 2S TK26 86VU 1WT2-AA 2G D
6 86VU 1860VT 29J 3161-7170 R 2S TK26 86VU 1WT2-AA 2F D
7 86VU 3152G7145 W.F. 2286-0354 2S CF24 86VU 3411G7171 W.F. D
8 86VU 3411G7171 W.F. 2286-0354 2S CF24 128 2286G7194 W.F. D
9 128 2286G7194 W.F. 2286-0354 2S CF24 128 2286G7233 W.F. D
10 128 2286G7233 W.F. 2286-0354 2S CF24 84VU 2286G7195 W.F. D
11 84VU 2286G7195 W.F. 2286-0354 2S CF24 88VU 3448G7068 W.F. D
12 88VU 3448G7068 W.F. 2286-0354 2S CF24 86VU 3161G7170 W.F. D
13 86VU 3161G7170 W.F. 2286-0354 2S CF24 86VU 3161G7167 W.F. D
14 86VU 3161G7167 W.F. 2286-0354 2S CF24 86VU 3152G7145 W.F. D
15 86VU 1860VT SH 2286G7194 2S TK26 128 36VC SH D
16 86VU 1860VT 29G 2286-7194 B 2S TK26 128 36VC 16 D
17 86VU 1860VT 29H 2286-7194 R 2S TK26 128 36VC 15 D
18 86VU 1860VT SH 2286G7195 2S TK26 84VU 1CA2-AB SH D
19 86VU 1860VT 29F 2286-7195 B 2S TK26 84VU 1CA2-AB 5K D
20 86VU 1860VT 29C 2286-7195 R 2S TK26 84VU 1CA2-AB 5J D
21 86VU 1860VT SH 2286G7233 2S TK26 128 36VC SH D
22 86VU 1860VT 29N 2286-7233 B 2S TK26 128 36VC 12 D
23 86VU 1860VT 29R 2286-7233 R 2S TK26 128 36VC 11 D
24
25
D = DELETED WIRE
SH = SHIELD
W.F. = WIRE FERRULE
CONF 001
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 86VU 1860VT SH 3161G7167 2S TK26 85VU 1WT3-AA SH D
2 85VU 1WT3-AA 2G 3161-7167 B 2S TK26 86VU 1860VT 29M D
3 86VU 1860VT 29K 3161-7167 R 2S TK26 85VU 1WT3-AA 2F D
4 86VU 1860VT SH 3411G7171 2S TK26 128 152VC SH D
5 86VU 1860VT 29D 3411-7171 B 2S TK26 128 152VC 20 D
6 86VU 1860VT 29A 3411-7171 R 2S TK26 128 152VC 14 D
7 86VU 1860VT SH 3448G7068 2S TK26 88VU 1WZ-AA SH D
8 88VU 1WZ-AA 9D 3448-7068 B 2S TK26 86VU 1860VT 29X D
9 86VU 1860VT 29T 3448-7068 R 2S TK26 88VU 1WZ-AA 9C D
10 86VU 2286G7194 W.F. 2286-0349 2S CF24 128 36VC 17 D
11 86VU 2286G7233 W.F. 2286-0450 2S CF24 128 36VC 13 D
12 128 3411G7171 W.F. 3411-0301 2S CF24 128 152VC 13 D
13
14
15
16
17
18
19
20
21
22
23
24
25
D = DELETED WIRE
SH = SHIELD
W.F. = WIRE FERRULE
CONF 001
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 86VU 1860VT SH E0718-02-30 3152G7145 2S TK26 1500 60 86VU 1WW2-AE SH E0718-02-30 (c) A (b) (d)(1)
2 86VU 1860VT 37P EN3155-016M2222 3152-7145 B 2S TK26 1500 60 86VU 1WW2-AE 8B E0170FA2200 (c) A (b) (d)(1)
3 86VU 1860VT 36P EN3155-016M2222 3152-7145 R 2S TK26 1500 60 86VU 1WW2-AE 8A E0170FA2200 (c) A (b) (d)(1)
4 86VU 1860VT SH E0718-02-30 3161G7170 2S TK26 1000 40 86VU 1WT2-AA SH E0718-02-30 (c) A (b) (d)(1)
5 86VU 1860VT 37G EN3155-016M2222 3161-7170 B 2S TK26 1000 40 86VU 1WT2-AA 2G E0170FA2200 (c) A (b) (d)(1)
6 86VU 1860VT 36G EN3155-016M2222 3161-7170 R 2S TK26 1000 40 86VU 1WT2-AA 2F E0170FA2200 (c) A (b) (d)(1)
7 86VU 3152G7145 W.F. E0160-1-0H 2286-0354 2S CF24 5000 200 128 3411G7171 W.F. E0160-1-0H (c) A (b) (d)(1)
8 128 3411G7171 W.F. E0160-1-0H 2286-0354 2S CF24 5000 200 128 2286G7194 W.F. E0160-1-0H (c) A (b) (d)(1)
9 128 2286G7194 W.F. E0160-1-0H 2286-0354 2S CF24 5000 200 86VU 2286G7233 W.F. E0160-1-0H (c) A (b) (d)(1)
10 86VU 2286G7233 W.F. E0160-1-0H 2286-0354 2S CF24 5000 200 84VU 2286G7195 W.F. E0160-1-0H (c) A (b) (d)(1)
11 84VU 2286G7195 W.F. E0160-1-0H 2286-0354 2S CF24 5000 200 88VU 3448G7068 W.F. E0160-1-0H (c) A (b) (d)(1)
12 88VU 3448G7068 W.F. E0160-1-0H 2286-0354 2S CF24 5000 200 86VU 3161G7170 W.F. E0160-1-0H (c) A (b) (d)(1)
13 86VU 3161G7170 W.F. E0160-1-0H 2286-0354 2S CF24 5000 200 86VU 3161G7167 W.F. E0160-1-0H (c) A (b) (d)(1)
14 86VU 3161G7167 W.F. E0160-1-0H 2286-0354 2S CF24 5000 200 86VU 3452G7082 W.F. E0160-1-0H (c) A (b) (d)(1)
15 86VU 3452G7082 W.F. E0160-1-0H 2286-0354 2S CF24 5000 200 86VU 3452G7081 W.F. E0160-1-0H (c) A (b) (d)(1)
16 86VU 3452G7081 W.F. E0160-1-0H 2286-0354 2S CF24 5000 200 86VU 3152G7145 W.F. E0160-1-0H (c) A (b) (d)(1)
17 86VU 1860VT SH E0718-02-30 2286G7194 2S TK26 3000 120 128 36VC SH E0718-02-30 (c) A (b) (d)(1)
18 86VU 1860VT 37L EN3155-016M2222 2286-7194 B 2S TK26 3000 120 128 36VC 16 EN3155-008M2222 (c) A (b) (d)(1)
19 86VU 1860VT 36L EN3155-016M2222 2286-7194 R 2S TK26 3000 120 128 36VC 15 EN3155-008M2222 (c) A (b) (d)(1)
20 86VU 1860VT SH E0718-02-30 2286G7195 2S TK26 3000 120 84VU 1CA2-AB SH E0718-02-30 (c) A (b) (d)(1)
21 86VU 1860VT 37M EN3155-016M2222 2286-7195 B 2S TK26 3000 120 84VU 1CA2-AB 5K E0170FA2200 (c) A (b) (d)(1)
22 86VU 1860VT 36M EN3155-016M2222 2286-7195 R 2S TK26 3000 120 84VU 1CA2-AB 5J E0170FA2200 (c) A (b) (d)(1)
23 86VU 1860VT SH E0718-02-30 2286G7233 2S TK26 3000 120 128 36VC SH E0718-02-30 (c) A (b) (d)(1)
24 86VU 1860VT 37N EN3155-016M2222 2286-7233 B 2S TK26 3000 120 128 36VC 12 EN3155-008M2222 (c) A (b) (d)(1)
25 86VU 1860VT 36N EN3155-016M2222 2286-7233 R 2S TK26 3000 120 128 36VC 11 EN3155-008M2222 (c) A (b) (d)(1)
(c) = BUNDLE D9000095461195 W.F. = WIRE FERRULE (1) = (b) = D9000095460995 OR
A = ADDED WIRE (c) = D9000095461195 OR
SH = SHIELD (d) = D9000095461295
CONF 001
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 86VU 1860VT SH E0718-02-30 3161G7167 2S TK26 3000 120 85VU 1WT3-AA SH E0718-02-30 (c) A (b) (d)(1)
2 85VU 1WT3-AA 2G E0170FA2200 3161-7167 B 2S TK26 3000 120 86VU 1860VT 37F EN3155-016M2222 (c) A (b) (d)(1)
3 86VU 1860VT 36F EN3155-016M2222 3161-7167 R 2S TK26 3000 120 85VU 1WT3-AA 2F E0170FA2200 (c) A (b) (d)(1)
4 86VU 1860VT SH E0718-02-30 3411G7171 2S TK26 4500 180 128 152VC SH E0718-02-30 (c) A (b) (d)(1)
5 86VU 1860VT 37X EN3155-016M2222 3411-7171 B 2S TK26 4500 180 128 152VC 20 EN3155-008M2222 (c) A (b) (d)(1)
6 86VU 1860VT 36X EN3155-016M2222 3411-7171 R 2S TK26 4500 180 128 152VC 14 EN3155-008M2222 (c) A (b) (d)(1)
7 86VU 1860VT SH E0718-02-30 3448G7068 2S TK26 2500 100 88VU 1WZ-AA SH E0718-02-30 (c) A (b) (d)(1)
8 88VU 1WZ-AA 9D E0170FA2200 3448-7068 B 2S TK26 2500 100 86VU 1860VT 37U EN3155-016M2222 (c) A (b) (d)(1)
9 86VU 1860VT 36U EN3155-016M2222 3448-7068 R 2S TK26 2500 100 88VU 1WZ-AA 9C E0170FA2200 (c) A (b) (d)(1)
10 86VU 1860VT SH E0718-02-30 3452G7081 2S TK26 3500 140 82VU 1SH2-AB SH E0718-02-30 (c) A (b) (d)(1)
11 82VU 1SH2-AB 3G E0170FA2200 3452-7081 B 2S TK26 3500 140 86VU 1860VT 37D EN3155-016M2222 (c) A (b) (d)(1)
12 86VU 1860VT 36D EN3155-016M2222 3452-7081 R 2S TK26 3500 140 82VU 1SH2-AB 3F E0170FA2200 (c) A (b) (d)(1)
13 86VU 1860VT SH E0718-02-30 3452G7082 2S TK26 3500 140 82VU 1SH2-AA SH E0718-02-30 (c) A (b) (d)(1)
14 82VU 1SH2-AA 7B E0170FA2200 3452-7082 B 2S TK26 3500 140 86VU 1860VT 37E EN3155-016M2222 (c) A (b) (d)(1)
15 86VU 1860VT 36E EN3155-016M2222 3452-7082 R 2S TK26 3500 140 82VU 1SH2-AA 7A E0170FA2200 (c) A (b) (d)(1)
16 86VU 2286G7194 W.F. E0160-1-0H 2286-0349 2S CF24 500 20 128 36VC 17 EN3155-008M2222 (c) A (b) (d)(1)
17 86VU 3411G7171 W.F. E0160-1-0H 3411-0301 2S CF24 500 20 128 152VC 13 EN3155-008M2222 (c) A (b) (d)(1)
18 128 2286G7233 W.F. E0160-1-0H 2286-0450 2S CF24 500 20 128 36VC 13 EN3155-008M2222 (c) A (b) (d)(1)
19
20
21
22
23
24
25
(c) = BUNDLE D9000095461195 W.F. = WIRE FERRULE (1) = (b) = D9000095460995 OR
A = ADDED WIRE (c) = D9000095461195 OR
SH = SHIELD (d) = D9000095461295
CONF 001
BEFORE
0330
34
0329
47
F.R.
32 R R
7168
33 B
A 106VC
128 AE
U R 7E
3152-7209
34 B 7F
3411-1628
T R 9C
3152-7208
F.R. B 9D
1WW2
32 R S FWC-2
3411-7418 86VU
33 B 128
A 154VC
128
B
1862VT
128
86VU
DELETED WIRE F.R. FOR REFERENCE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 3436
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK26 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 2M
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-34XX1620-A-FAPE3-00MGD-A-002-01
CONF 001
AFTER
0330
54 AA
34 A R 6H
3452-7083
0329
B 6J
F.R.
1SH2
32 R B XPDR
7168 ATC-2
33 B 82VU
128
A 106VC
128 AE
C R 7E
3152-7209
B 7F
G
D R 9C
3152-7208
B 9D
F
1WW2
E FWC-2
86VU
128
H
34
3411-1628
J
F.R.
P
32 R
3411-7418 K
33 B
A 154VC N
128
M
1862VT
128
86VU
NEW WIRE STOWED WIRE F.R. FOR REFERENCE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 3436
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK26 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 2M
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-34XX1620-A-FAPE3-00MGE-A-002-01
CONF 001
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 86VU 1WW2-AE SH 3152G7208 2M TK26 86VU 1862VT SH D
2 86VU 1WW2-AE 9D 3152-7208 B 2M TK26 86VU 1862VT 47C D
3 86VU 1WW2-AE 9C 3152-7208 R 2M TK26 86VU 1862VT 47T D
4 86VU 1WW2-AE SH 3152G7209 2M TK26 86VU 1862VT SH D
5 86VU 1WW2-AE 7F 3152-7209 B 2M TK26 86VU 1862VT 47D D
6 86VU 1WW2-AE 7E 3152-7209 R 2M TK26 86VU 1862VT 47U D
7 86VU 3436G7168 W.F. 3436-0330 2M CF24 86VU 3411G7418 W.F. D
8 86VU 3411G7418 W.F. 3436-0330 2M CF24 86VU 3152G7208 W.F. D
9 86VU 3152G7208 W.F. 3436-0330 2M CF24 86VU 3152G7209 W.F. D
10 86VU 3152G7209 W.F. 3436-0330 2M CF24 86VU 3436G7168 W.F. D
11 86VU 1862VT SH 3411G7418 2M TK26 128 154VC SH D
12 86VU 1862VT 47B 3411-7418 B 2M TK26 128 154VC 33 D
13 86VU 1862VT 47S 3411-7418 R 2M TK26 128 154VC 32 D
14 86VU 1862VT SH 3436G7168 2M TK26 128 106VC SH D
15 86VU 1862VT 47A 3436-7168 B 2M TK26 128 106VC 33 D
16 86VU 1862VT 47R 3436-7168 R 2M TK26 128 106VC 32 D
17 128 3411G7418 W.F. 3411-1628 2M CF24 128 154VC 34 D
18 128 3436G7168 W.F. 3436-0329 2M CF24 128 106VC 34 D
19
20
21
22 86VU 1WW2-AE SH E0718-02-30 3152G7208 2M TK26 2000 80 86VU 1862VT SH E0718-02-30 (a) A
23 86VU 1WW2-AE 9D E0170FA2200 3152-7208 B 2M TK26 2000 80 86VU 1862VT 54L EN3155-016M2222 (a) A
24 86VU 1WW2-AE 9C E0170FA2200 3152-7208 R 2M TK26 2000 80 86VU 1862VT 54D EN3155-016M2222 (a) A
25
(a) = BUNDLE D9000095460895 SH = SHIELD
A = ADDED WIRE W.F. = WIRE FERRULE
D = DELETED WIRE
CONF 001
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 86VU 1WW2-AE SH E0718-02-30 3152G7209 2M TK26 2000 80 86VU 1862VT SH E0718-02-30 (a) A
2 86VU 1WW2-AE 7F E0170FA2200 3152-7209 B 2M TK26 2000 80 86VU 1862VT 54K EN3155-016M2222 (a) A
3 86VU 1WW2-AE 7E E0170FA2200 3152-7209 R 2M TK26 2000 80 86VU 1862VT 54C EN3155-016M2222 (a) A
4 86VU 3436G7168 W.F. E0160-1-0H 3436-0330 2M CF24 2500 100 86VU 3411G7418 W.F. E0160-1-0H (a) A
5 86VU 3411G7418 W.F. E0160-1-0H 3436-0330 2M CF24 2500 100 86VU 3152G7208 W.F. E0160-1-0H (a) A
6 86VU 3152G7208 W.F. E0160-1-0H 3436-0330 2M CF24 2500 100 86VU 3152G7209 W.F. E0160-1-0H (a) A
7 86VU 3152G7209 W.F. E0160-1-0H 3436-0330 2M CF24 2500 100 86VU 3452G7083 W.F. E0160-1-0H (a) A
8 86VU 3452G7083 W.F. E0160-1-0H 3436-0330 2M CF24 2500 100 86VU 3436G7168 W.F. E0160-1-0H (a) A
9 86VU 1862VT SH E0718-02-30 3411G7418 2M TK26 2500 100 128 154VC SH E0718-02-30 (a) A
10 86VU 1862VT 54M EN3155-016M2222 3411-7418 B 2M TK26 2500 100 128 154VC 33 EN3155-008M2222 (a) A
11 86VU 1862VT 54E EN3155-016M2222 3411-7418 R 2M TK26 2500 100 128 154VC 32 EN3155-008M2222 (a) A
12 86VU 1862VT SH E0718-02-30 3436G7168 2M TK26 3500 140 128 106VC SH E0718-02-30 (a) A
13 86VU 1862VT 54J EN3155-016M2222 3436-7168 B 2M TK26 3500 140 128 106VC 33 EN3155-008M2222 (a) A
14 86VU 1862VT 54B EN3155-016M2222 3436-7168 R 2M TK26 3500 140 128 106VC 32 EN3155-008M2222 (a) A
15 86VU 1862VT SH E0718-02-30 3452G7083 2M TK26 3500 140 82VU 1SH2-AA SH E0718-02-30 (a) A
16 82VU 1SH2-AA W.S. NSA936604CA0931 3452-7083 B 2M TK26 3500 140 86VU 1862VT W.S. NSA936604CA0931 (a) A
17 86VU 1862VT W.S. NSA936604CA0931 3452-7083 R 2M TK26 3500 140 82VU 1SH2-AA W.S. NSA936604CA0931 (a) A
18 128 3411G7418 W.F. E0160-1-0H 3411-1628 2M CF24 500 20 128 154VC 34 EN3155-008M2222 (a) A
19 128 3436G7168 W.F. E0160-1-0H 3436-0329 2M CF24 500 20 128 106VC 34 EN3155-008M2222 (a) A
20
21
22
23
24
25
(a) = BUNDLE D9000095460895 W.F. = WIRE FERRULE
A = ADDED WIRE W.S. = WIRE STOWED
SH = SHIELD
CONF 001
BEFORE
0303
F.R. 48
67 R U
F.R. 3411-7417
68 B
A 153VC
127 AB
T R 7E
3152-7203
B 7F
S R 9G
3152-7202
B 9H
1WW1 FWC-1
R 85VU
127
69 R
F.R. 7153
70 B A
A 11VC F.R.
127
1853VT
127
85VU
CONF 001
AFTER
0303
31 AA
A R 6H
3452-7093
B 6J
F 1SH1 XPDR
ATC-1
81VU
127
AB
C R 7E
3152-7203
B 7F
G
D R 9G
F.R. 3152-7202
B 9H
67 R B
F.R. 3411-7417
68 B 1WW1 FWC-1
E 85VU
A 153VC 127
127
69 R
F.R. 7153
70 B K
A 11VC
127 F.R.
L
1853VT
127
85VU
CONF 001
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 85VU 1WW1-AB SH 3152G7202 1M TK26 85VU 1853VT SH D
2 85VU 1WW1-AB 9H 3152-7202 B 1M TK26 85VU 1853VT 48B D
3 85VU 1WW1-AB 9G 3152-7202 R 1M TK26 85VU 1853VT 48S D
4 85VU 1WW1-AB SH 3152G7203 1M TK26 85VU 1853VT SH D
5 85VU 1WW1-AB 7F 3152-7203 B 1M TK26 85VU 1853VT 48C D
6 85VU 1WW1-AB 7E 3152-7203 R 1M TK26 85VU 1853VT 48T D
7 85VU 1853VT SH 3411G7417 1M TK26 127 153VC SH D
8 85VU 1853VT 48D 3411-7417 B 1M TK26 127 153VC 68 D
9 85VU 1853VT 48U 3411-7417 R 1M TK26 127 153VC 67 D
10 85VU 1853VT SH 3436G7153 1M TK26 127 11VC SH D
11 85VU 1853VT 48A 3436-7153 B 1M TK26 127 11VC 70 D
12 85VU 1853VT 48R 3436-7153 R 1M TK26 127 11VC 69 D
13 127 3436G7153 W.F. 3436-0303 1M CF24 85VU 3152G7202 W.F. D
14 85VU 3152G7202 W.F. 3436-0303 1M CF24 85VU 3152G7203 W.F. D
15 85VU 3152G7203 W.F. 3436-0303 1M CF24 85VU 3411G7417 W.F. D
16 85VU 3411G7417 W.F. 3436-0303 1M CF24 127 3436G7153 W.F. D
17
18
19
20 85VU 1WW1-AB SH E0718-02-30 3152G7202 1M TK26 3500 140 85VU 1853VT SH E0718-02-30 (b) A
21 85VU 1WW1-AB 9H E0170FA2200 3152-7202 B 1M TK26 3500 140 85VU 1853VT 31M EN3155-016M2222 (b) A
22 85VU 1WW1-AB 9G E0170FA2200 3152-7202 R 1M TK26 3500 140 85VU 1853VT 31D EN3155-016M2222 (b) A
23 85VU 1WW1-AB SH E0718-02-30 3152G7203 1M TK26 3500 140 85VU 1853VT SH E0718-02-30 (b) A
24 85VU 1WW1-AB 7F E0170FA2200 3152-7203 B 1M TK26 3500 140 85VU 1853VT 31L EN3155-016M2222 (b) A
25 85VU 1WW1-AB 7E E0170FA2200 3152-7203 R 1M TK26 3500 140 85VU 1853VT 31C EN3155-016M2222 (b) A
(b) = BUNDLE D9000095460995 SH = SHIELD
A = ADDED WIRE W.F. = WIRE FERRULE
D = DELETED WIRE
CONF 001
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 85VU 1853VT SH E0718-02-30 3411G7417 1M TK26 3500 140 127 153VC SH E0718-02-30 (b) A
2 85VU 1853VT 31J EN3155-016M2222 3411-7417 B 1M TK26 3500 140 127 153VC 68 EN3155-008M2222 (b) A
3 85VU 1853VT 31B EN3155-016M2222 3411-7417 R 1M TK26 3500 140 127 153VC 67 EN3155-008M2222 (b) A
4 85VU 1853VT SH E0718-02-30 3436G7153 1M TK26 3500 140 127 11VC SH E0718-02-30 (b) A
5 85VU 1853VT 31K EN3155-016M2222 3436-7153 B 1M TK26 3500 140 127 11VC 70 EN3155-008M2222 (b) A
6 85VU 1853VT 31E EN3155-016M2222 3436-7153 R 1M TK26 3500 140 127 11VC 69 EN3155-008M2222 (b) A
7 85VU 1853VT SH E0718-02-30 3452G7093 1M TK26 3500 140 81VU 1SH1-AA SH E0718-02-30 (b) A
8 81VU 1SH1-AA W.S. NSA936604CA0931 3452-7093 B 1M TK26 3500 140 85VU 1853VT W.S. NSA936604CA0931 (b) A
9 85VU 1853VT W.S. NSA936604CA0931 3452-7093 R 1M TK26 3500 140 81VU 1SH1-AA W.S. NSA936604CA0931 (b) A
10 127 3436G7153 W.F. E0160-1-0H 3436-0303 1M CF24 2500 100 85VU 3152G7202 W.F. E0160-1-0H (b) A
11 85VU 3152G7202 W.F. E0160-1-0H 3436-0303 1M CF24 2500 100 85VU 3152G7203 W.F. E0160-1-0H (b) A
12 85VU 3152G7203 W.F. E0160-1-0H 3436-0303 1M CF24 2500 100 85VU 3452G7093 W.F. E0160-1-0H (b) A
13 85VU 3452G7093 W.F. E0160-1-0H 3436-0303 1M CF24 2500 100 85VU 3411G7417 W.F. E0160-1-0H (b) A
14 85VU 3411G7417 W.F. E0160-1-0H 3436-0303 1M CF24 2500 100 127 3436G7153 W.F. E0160-1-0H (b) A
15
16
17
18
19
20
21
22
23
24
25
(b) = BUNDLE D9000095460995 W.F. = WIRE FERRULE
A = ADDED WIRE W.S. = WIRE STOWED
SH = SHIELD
CONF 001
BEFORE
41
AA F.R. V
2E B D
3161-7165 F.R. AB
2D R - F.R.
B 5B
42 3137-7066
1WT3 DMC-3 V R 5A
85VU
127 D
1TV DMU
- F.R. OR
10TV FDIMU
1851VT 87VU
127 85VU 127
0343 S
AFTER
F.R. AB
41
AA F.R. V R 5B
3137-7066
2E B D B 5A
3161-7165
2D R X
1TV DMU
Y OR
1WT3 DMC-3 10TV FDIMU
85VU - F.R. 87VU
127 127
42
V AA
D B 7B
3452-7091
X R 7A
Y AB
- F.R. B 3G
3452-7092
1851VT R 3F .
127 85VU
CONF 001
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 87VU 3137G7066 W.F. 2286S0343 1S CF24 85VU 3161G7165 W.F. D
2 85VU 3137G7066 W.F. E0160-1-0H 2286S0343 1S CF24 1500 60 81VU 3452G7091 W.F. E0160-1-0H (a) A (c) (1)
3 81VU 3452G7091 W.F. E0160-1-0H 2286S0343 1S CF24 1500 60 81VU 3452G7092 W.F. E0160-1-0H (a) A (c) (1)
4 81VU 3452G7092 W.F. E0160-1-0H 2286S0343 1S CF24 1500 60 85VU 3161G7165 W.F. E0160-1-0H (a) A (c) (1)
5 81VU 1SH1-AA SH E0718-02-30 3452G7091 1S TK26 4000 160 85VU 1851VT SH E0718-02-30 (a) A (c) (1)
6 81VU 1SH1-AA 7B E0170FA2200 3452-7091 B 1S TK26 4000 160 85VU 1851VT 41X EN3155-016M2222 (a) A (c) (1)
7 81VU 1SH1-AA 7A E0170FA2200 3452-7091 R 1S TK26 4000 160 85VU 1851VT 42X EN3155-016M2222 (a) A (c) (1)
8 81VU 1SH1-AB SH E0718-02-30 3452G7092 1S TK26 4000 160 85VU 1851VT SH E0718-02-30 (a) A (c) (1)
9 81VU 1SH1-AB 3G E0170FA2200 3452-7092 B 1S TK26 4000 160 85VU 1851VT 41Y EN3155-016M2222 (a) A (c) (1)
10 81VU 1SH1-AB 3F E0170FA2200 3452-7092 R 1S TK26 4000 160 85VU 1851VT 42Y EN3155-016M2222 (a) A (c) (1)
11
12
13
14 87VU 1TV-AB SH E0718-02-30 3137G7066 1S TK26 85VU 1851VT SH E0718-02-30 F.R.
15 87VU 1TV-AB 5B 3137-7066 B 1S TK26 85VU 1851VT 41V F.R.
16 85VU 1851VT 42V 3137-7066 R 1S TK26 87VU 1TV-AB 5A F.R.
17 85VU 1WT3-AA SH E0718-02-30 3161G7165 1S TK26 85VU 1851VT SH E0718-02-30 F.R.
18 85VU 1WT3-AA 2E 3161-7165 B 1S TK26 85VU 1851VT 41D F.R.
19 85VU 1WT3-AA 2D 3161-7165 R 1S TK26 85VU 1851VT 42D F.R.
20
21
22
23
24
25
(a) = BUNDLE D9000095460895 F.R. = FOR REFERENCE S = SAFETY WIRE
A = ADDED WIRE SH = SHIELD (1) = (a) = D9000095460895 OR
D = DELETED WIRE W.F. = WIRE FERRULE (c) = D9000095461195
CONF 001
BEFORE
76 72
1630
1626
F.R. F.R.
77 7416 R 70
TK26
78 B 71
A 11VC 153VC A
127 127
37 37
1631
1629
F.R. F.R.
2M
35 R 35
7419
TK26 B
36 36
A 106VC 154VC A
128 128
CONF 001
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 127 11VC SH 3411G7416 1M TK26 127 153VC SH D
2 127 11VC 78 3411-7416 B 1M TK26 127 153VC 71 D
3 127 11VC 77 3411-7416 R 1M TK26 127 153VC 70 D
4 128 106VC SH 3411G7419 2M TK26 128 154VC SH D
5 128 106VC 36 3411-7419 B 2M TK26 128 154VC 36 D
6 128 106VC 35 3411-7419 R 2M TK26 128 154VC 35 D
7 127 3411G7416 W.F. 3411-1626 1M CF24 127 153VC 72 D
8 128 3411G7419 W.F. 3411-1629 2M CF24 128 154VC 37 D
9 127 3411G7416 W.F. 3411-1630 1M CF24 127 11VC 76 D
10 128 3411G7419 W.F. 3411-1631 2M CF24 128 106VC 37 D
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
D = DELETED WIRE
SH = SHIELD
W.F. = WIRE FERRULE
CONF 001
AFTER
31
77 R A
7226 AA
F.R. 78 B
B R 6D
76 0437 3452-7094
- B 6E
A 11VC C F.R. -
127
H 1SH1
XPDR
ATC-1
J 81VU
70 R 127
3411-7416 -
71 B K
1813VT
3411-1626
127
F.R. 81VU
0438
72
A 153VC
127
CONF 001
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 81VU 1SH1-AA SH E0718-02-30 3452G7094 1M TK26 1500 60 81VU 1813VT SH E0718-02-30 (a) A
2 81VU 1SH1-AA W.S. NSA936604CA0931 3452-7094 B 1M TK26 1500 60 81VU 1813VT W.S. NSA936604CA0931 (a) A
3 81VU 1SH1-AA W.S. NSA936604CA0931 3452-7094 R 1M TK26 1500 60 81VU 1813VT W.S. NSA936604CA0931 (a) A
4 81VU 3436G7226 W.F. E0160-1-0H 3436-0438 1M CF24 1000 40 81VU 3452G7094 W.F. E0160-1-0H (a) A
5 81VU 3452G7094 W.F. E0160-1-0H 3436-0438 1M CF24 1000 40 81VU 3411G7416 W.F. E0160-1-0H (a) A
6 81VU 1813VT SH E0718-02-30 3411G7416 1M TK26 3500 140 127 153VC SH E0718-02-30 (a) A
7 81VU 1813VT 31K EN3155-016M2222 3411-7416 B 1M TK26 3500 140 127 153VC 71 EN3155-008M2222 (a) A
8 81VU 1813VT 31C EN3155-016M2222 3411-7416 R 1M TK26 3500 140 127 153VC 70 EN3155-008M2222 (a) A
9 81VU 1813VT SH E0718-02-30 3436G7226 1M TK26 2000 80 127 11VC SH E0718-02-30 (a) A
10 81VU 1813VT 31H EN3155-016M2222 3436-7226 B 1M TK26 2000 80 127 11VC 78 EN3155-008M2222 (a) A
11 81VU 1813VT 31A EN3155-016M2222 3436-7226 R 1M TK26 2000 80 127 11VC 77 EN3155-008M2222 (a) A
12 127 3411G7416 W.F. E0160-1-0H 3411-1626 1M CF24 500 20 127 153VC 72 EN3155-008M2222 (a) A
13 127 3436G7226 W.F. E0160-1-0H 3436-0437 1M CF24 500 20 127 11VC 76 EN3155-008M2222 (a) A
14
15
16
17
18
19
20
21
22
23
24
25
(a) = BUNDLE D9000095460895 W.F. = WIRE FERRULE
A = ADDED WIRE W.S. = WIRE STOWED
SH = SHIELD
CONF 001
AFTER
37
3411-1629
0427
F.R.
39
35 R B
3411-7419
36 B
A 154VC
128 AA
A R 6D
3452-7084
B 6E
-
1SH2 XPDR
35 R C ATC-2
7223 82VU
36 B 128
0428
F.R.
37
A 106VC -
128
K
1822VT
128
82VU
CONF 001
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 82VU 1SH2-AA SH E0718-02-30 3452G7084 2M TK26 1000 40 82VU 1822VT SH E0718-02-30 (a) A
2 82VU 1822VT W.S. NSA936604CA0931 3452-7084 B 2M TK26 1000 40 82VU 1SH2-AA W.S. NSA936604CA0931 (a) A
3 82VU 1SH2-AA W.S. NSA936604CA0931 3452-7084 R 2M TK26 1000 40 82VU 1822VT W.S. NSA936604CA0931 (a) A
4 82VU 3436G7223 W.F. E0160-1-0H 3436-0427 2M CF24 1000 40 82VU 3452G7084 W.F. E0160-1-0H (a) A
5 82VU 3452G7084 W.F. E0160-1-0H 3436-0427 2M CF24 1000 40 82VU 3411G7419 W.F. E0160-1-0H (a) A
6 82VU 1822VT SH E0718-02-30 3411G7419 2M TK26 3500 140 128 154VC SH E0718-02-30 (a) A
7 82VU 1822VT 39J EN3155-016M2222 3411-7419 B 2M TK26 3500 140 128 154VC 36 EN3155-008M2222 (a) A
8 82VU 1822VT 39B EN3155-016M2222 3411-7419 R 2M TK26 3500 140 128 154VC 35 EN3155-008M2222 (a) A
9 82VU 1822VT SH E0718-02-30 3436G7223 2M TK26 3000 120 128 106VC SH E0718-02-30 (a) A
10 82VU 1822VT 39K EN3155-016M2222 3436-7223 B 2M TK26 3000 120 128 106VC 36 EN3155-008M2222 (a) A
11 82VU 1822VT 39C EN3155-016M2222 3436-7223 R 2M TK26 3000 120 128 106VC 35 EN3155-008M2222 (a) A
12 128 3411G7419 W.F. E0160-1-0H 3411-1629 2M CF24 500 20 128 154VC 37 EN3155-008M2222 (a) A
13 128 3436G7223 W.F. E0160-1-0H 3436-0428 2M CF24 500 20 128 106VC 37 EN3155-008M2222 (a) A
14
15
16
17
18
19
20
21
22
23
24
25
(a) = BUNDLE D9000095460895 W.F. = WIRE FERRULE
A = ADDED WIRE W.S. = WIRE STOWED
SH = SHIELD
CONF 002
(1) Task A320-A-34-XX-1620-01002-920A-A - Modify the Equipment and the
Wiring in the Aft Electronics Rack 80VU
Job Set-Up Information
Working Area
Man-hours 35.00 h
Minimum Number of person 1
Elapsed Time 35.00 h
Material necessary to do the job
Part kit 341620A03R00
ITEM PART No. QTY (UM) KEYWORD DRAWING SEE NOTES
D9000095461195 1 BUNDLE
NSA935401-05 150 TIE
NSA935401-08 150 TIE
NSA935401-13 150 TIE
NSA937901E0 1 LABEL
NSA937901E1 2 LABEL
NSA937901E2 1 LABEL
NSA937901E3 2 LABEL
NSA937901E6 1 LABEL
NSA937901E7 1 LABEL
NSA937901FM 3 MODULE
NSA937901MA2205 4 MODULE
Referenced Information
Manuals/Drawings References/Sheets
Task 22-66-34-000-002
Task 22-66-34-400-002
Task 22-83-34-000-001
Task 22-83-34-400-001
Task 27-93-34-000-001
Task 27-93-34-400-001
Task 27-94-34-000-001
AMM Task 27-94-34-400-001
Task 31-36-34-000-001
Task 31-36-34-400-001
Task 31-53-34-000-001
Task 31-53-34-400-001
Task 31-63-34-000-001
Task 31-63-34-400-001
Task 34-43-34-000-001
Manuals/Drawings References/Sheets
Task 34-43-34-400-001
Task 34-48-34-000-001
Task 34-48-34-400-001
Task 34-52-33-000-001
Task 34-52-33-400-001
20-33-00
20-33-44
ESPM
20-52-21
20-56-51
Procedure
(a) Standard Practices:
1 For the general installation of electrical wire harnesses, refer to Ref. ESPM
20-33-00.
2 For the cable tie application and tooling, refer to Ref. ESPM 20-33-44 and
Ref. ESPM 20-56-51.
3 Tag all the parts you must remove and retain to make the subsequent
installation easier.
4 Put all the retained hardware in identified plastic bags and attach the bags
to the related unit.
5 To install new wires, cut them to the necessary length, attach the terminals
and connect them.
(b) Remove and retain the FMGCs ( FIN 1CA1 and FIN 1CA2), refer to Ref. AMM Task
22-83-34-000-001.
(c) Remove and retain the FACs ( FIN 1CC1 and FIN 1CC2), refer to Ref. AMM Task
22-66-34-000-002.
(d) Remove and retain the SECs ( FIN 1CE1 and FIN 1CE2), refer to Ref. AMM Task
27-94-34-000-001.
(e) Remove and retain the ELACs ( FIN 2CE1 and FIN 2CE2), refer to Ref. AMM Task
27-93-34-000-001.
(f) Remove and retain the FWCs ( FIN 1WW1 and FIN 1WW2), refer to Ref. AMM Task
31-53-34-000-001.
(g) Remove and retain the DMCs ( FIN 1WT2 and FIN 1WT3), refer to Ref. AMM Task
31-63-34-000-001.
(h) Remove and retain the ATC/Mode S Transponders ( FIN 1SH1 and FIN 1SH2), refer
to Ref. AMM Task 34-52-33-000-001.
(i) Remove and retain the TCAS ( FIN 1SG), refer to Ref. AMM Task
34-43-34-000-001.
(j) Remove and retain the DMU ( FIN 1TV), refer to Ref. AMM Task
31-36-34-000-001.
(k) Remove and retain the GPWC ( FIN 1WZ), refer to Ref. AMM Task
34-48-34-000-001.
(l) Modify the equipment in the aft electronics rack Electrical Panel 80VU
Refer to Ref. Fig. Location of the Terminal Blocks in the Aft Electronics Rack 80VU
1 Modify the terminal block FIN 1831VT in the shelf Electrical Panel 83VU
1 MODULE-FALSE NSA937901FM
c Install at position 10:
FIN 1831VT10
1 MODULE NSA937901MA2205
FIN 1860VT29
1 MODULE NSA937901MA2205 Discard
c Install at position 29:
1 MODULE-FALSE NSA937901FM
d Install at position 35:
1 MODULE-FALSE NSA937901FM
e Install at position 36:
FIN 1860VT36
1 MODULE NSA937901MA2205
FIN 1860VT37
1 MODULE NSA937901MA2205
FIN 1840VT12
1 MODULE NSA937901MA2205
1 BUNDLE D9000095461195
3 Attach the wires with:
Refer to Ref. ESPM 20-33-44 and Ref. ESPM 20-56-51
(w) Install the FMGCs ( FIN 1CA1 and FIN 1CA2) retained at removal, refer to Ref.
AMM Task 22-83-34-400-001.
CONF 002
824
A
FR24
Z120
FR1
1822VT
1813VT
1840VT
1860VT
1862VT
1831VT 1853VT
A
80VU
ICN-A320-A-34XX1620-A-FAPE3-00MEY-A-002-01
CONF 002
0338 S 17
BEFORE
3457-0071
8
AE
V F.R.
7B B U
3443-7065
7A R
P B 16
X 3457-7077
1SG R 13
CMPTR D
TCAS Y 83VC A
82VU 127
128 E
AB
F AB
4K B
2286-7103 B 4K
4J R G 2269-7071
R 4J
1CA1 L
FMGC-1 1CC1
83VU FAC-1
127 M 83VU
127
N
AD
AA
4G B S
2792-7122 B S 9K
4F R S 2792-7152
T R S 9J
50 A
AA AD
E
2B B S B S 9B
M 2792-7123 B 2792-7150
2A R S R S 9A
F AA
F.R. - F.R. S
B 5D 2CE1 7S 7S 1CE1
3162-7188 ELAC-1 SEC-1
R R 5C 83VU H 83VU
127 127
C
J 1WT3
F.R. DMC3
14 B S 85VU 127 J
F.R. 7079
13 R S H B S
R
A 151VC 7230
127 F.R. -
A R S K
1851VT 1831VT
127 127
85VU 83VU
0825 S
DELETED WIRE F.R. FOR REFERENCE EXISTING WIRE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 3411
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK26 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 1S
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-34XX1620-A-FAPE3-00MG3-A-002-01
CONF 002
0338 S
AFTER
8 AA
X B 2B
AE V 3452-7095
R 2A
7B B U
3443-7065 Y
7A R 1SH1
P XPDR
ATC-1
1SG 81VU
CMPTR D 127
TCAS
82VU
128 E B 16
3457-7077
AB R 13
F
4K B
3457-0071
2286-7103
4J R G F.R.
1CA1 L
FMGC-1
83VU
127 M 17
83VC A
N 127
AD 10
AB
4G B S X
2792-7122 B 4K
4F R S V 2269-7071
U R 4J
Y
50 D 1CC1
AA FAC-1
E
2B B S 83VU
M 2792-7123 E 127
2A R S
F AA
F.R. - F.R. P
B 5D 2CE1 7S
ELAC-1 AA
3162-7188
R R 5C 83VU G B S 9K
127 2792-7152
R S 9J
F
J 1WT3
F.R. DMC3
85VU 127 AD
14 B S L
F.R. 7079 B S 9B
13 R S H B S 2792-7150
N R S 9A
A 151VC 7230
127 F.R. -
A R S M 1CE1
7S SEC-1
1851VT 1831VT 83VU
127 127 127
85VU 83VU
0825 S
NEW WIRE F.R. FOR REFERENCE EXISTING WIRE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 3411
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK26 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 1S
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-34XX1620-A-FAPE3-00MG4-A-002-01
CONF 002
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 83VU 1831VT SH 2269G7071 1S TK26 83VU 1CC1-AB SH D
2 83VU 1831VT 8E 2269-7071 B 1S TK26 83VU 1CC1-AB 4K D
3 83VU 1CC1-AB 4J 2269-7071 R 1S TK26 83VU 1831VT 8B D
4 83VU 1831VT SH 2286G7103 1S TK26 83VU 1CA1-AB SH D
5 83VU 1831VT 8D 2286-7103 B 1S TK26 83VU 1CA1-AB 4K D
6 83VU 1CA1-AB 4J 2286-7103 R 1S TK26 83VU 1831VT 8A D
7 83VU 1831VT SH 2792G7122 7S TK26 83VU 2CE1-AD SH D
8 83VU 1831VT 8G 2792S7122 B 7S TK26 83VU 2CE1-AD 4G D
9 83VU 1831VT 8H 2792S7122 R 7S TK26 83VU 2CE1-AD 4F D
10 83VU 1831VT SH 2792G7123 7S TK26 83VU 2CE1-AA SH D
11 83VU 1831VT 8F 2792S7123 B 7S TK26 83VU 2CE1-AA 2B D
12 83VU 1831VT 8C 2792S7123 R 7S TK26 83VU 2CE1-AA 2A D
13 83VU 1831VT SH 2792G7150 7S TK26 83VU 1CE1-AD SH D
14 83VU 1831VT 8N 2792S7150 B 7S TK26 83VU 1CE1-AD 9B D
15 83VU 1831VT 8R 2792S7150 R 7S TK26 83VU 1CE1-AD 9A D
16 83VU 1831VT SH 2792G7152 7S TK26 83VU 1CE1-AA SH D
17 83VU 1831VT 8L 2792S7152 B 7S TK26 83VU 1CE1-AA 9K D
18 83VU 1831VT 8J 2792S7152 R 7S TK26 83VU 1CE1-AA 9J D
19
20
21
22
23
24
25
D = DELETED WIRE
SH = SHIELD
S = SAFETY WIRE
CONF 002
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 83VU 2792G7122 W.F. 3411S0338 7S CF24 83VU 2792G7123 W.F. D
2 83VU 2792G7123 W.F. 3411S0338 7S CF24 83VU 3411G7230 W.F. D
3 83VU 3411G7230 W.F. 3411S0338 7S CF24 83VU 2792G7150 W.F. D
4 83VU 2792G7150 W.F. 3411S0338 7S CF24 83VU 2792G7152 W.F. D
5 83VU 2792G7152 W.F. 3411S0338 7S CF24 83VU 2269G7071 W.F. D
6 83VU 2269G7071 W.F. 3411S0338 7S CF24 83VU 3457G7077 W.F. D
7 83VU 3457G7077 W.F. 3411S0338 7S CF24 83VU 3443G7065 W.F. D
8 83VU 3443G7065 W.F. 3411S0338 7S CF24 83VU 2286G7103 W.F. D
9 83VU 2286G7103 W.F. 3411S0338 7S CF24 83VU 2792G7122 W.F. D
10 83VU 1831VT SH 3411G7230 1S TK26 85VU 1851VT SH D
11 83VU 1831VT 8M 3411S7230 B 1S TK26 85VU 1851VT 50F D
12 83VU 1831VT 8K 3411S7230 R 1S TK26 85VU 1851VT 50A D
13 83VU 1831VT SH 3443G7065 1S TK26 82VU 1SG-AE SH D
14 83VU 1831VT 8U 3443-7065 B 1S TK26 82VU 1SG-AE 7B D
15 83VU 1831VT 8T 3443-7065 R 1S TK26 82VU 1SG-AE 7A D
16 83VU 1831VT SH 3457G7077 1S TK26 127 83VC SH D
17 83VU 1831VT 8P 3457-7077 B 1S TK26 127 83VC 16 D
18 127 83VC 13 3457-7077 R 1S TK26 83VU 1831VT 8S D
19 85VU 3162G7188 W.F. 3411S0825 1S CF24 85VU 3411G7230 W.F. D
20 85VU 3411G7230 W.F. 3411S0825 1S CF24 127 3411G7079 W.F. D
21 127 3457G7077 W.F. 3457-0071 1S CF24 127 83VC 17 D
22
23
24
25
D = DELETED WIRE S = SAFETY WIRE
SH = SHIELD
W.F. = WIRE FERRULE
CONF 002
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 83VU 1831VT SH E0718-02-30 2269G7071 1S TK26 2000 80 83VU 1CC1-AB SH E0718-02-30 (c) A
2 83VU 1831VT 8E EN3155-016M2222 2269-7071 B 1S TK26 2000 80 83VU 1CC1-AB 4K E0170FA2200 (c) A
3 83VU 1CC1-AB 4J E0170FA2200 2269-7071 R 1S TK26 2000 80 83VU 1831VT 10E EN3155-016M2222 (c) A
4 83VU 1831VT SH E0718-02-30 2286G7103 1S TK26 1500 60 83VU 1CA1-AB SH E0718-02-30 (c) A
5 83VU 1831VT 8D EN3155-016M2222 2286-7103 B 1S TK26 1500 60 83VU 1CA1-AB 4K E0170FA2200 (c) A
6 83VU 1CA1-AB 4J E0170FA2200 2286-7103 R 1S TK26 1500 60 83VU 1831VT 10D EN3155-016M2222 (c) A
7 83VU 1831VT SH E0718-02-30 2792G7122 7S TK26 1500 60 83VU 2CE1-AD SH E0718-02-30 (c) A
8 83VU 1831VT 8G EN3155-016M2222 2792S7122 B 7S TK26 1500 60 83VU 2CE1-AD 4G E0170FA2200 (c) A
9 83VU 1831VT 10G EN3155-016M2222 2792S7122 R 7S TK26 1500 60 83VU 2CE1-AD 4F E0170FA2200 (c) A
10 83VU 1831VT SH E0718-02-30 2792G7123 7S TK26 1500 60 83VU 2CE1-AA SH E0718-02-30 (c) A
11 83VU 1831VT 8F EN3155-016M2222 2792S7123 B 7S TK26 1500 60 83VU 2CE1-AA 2B E0170FA2200 (c) A
12 83VU 1831VT 10F EN3155-016M2222 2792S7123 R 7S TK26 1500 60 83VU 2CE1-AA 2A E0170FA2200 (c) A
13 83VU 1831VT SH E0718-02-30 2792G7150 7S TK26 1000 40 83VU 1CE1-AD SH E0718-02-30 (c) A
14 83VU 1831VT 8N EN3155-016M2222 2792S7150 B 7S TK26 1000 40 83VU 1CE1-AD 9B E0170FA2200 (c) A
15 83VU 1831VT 10N EN3155-016M2222 2792S7150 R 7S TK26 1000 40 83VU 1CE1-AD 9A E0170FA2200 (c) A
16 83VU 1831VT SH E0718-02-30 2792G7152 7S TK26 1000 40 83VU 1CE1-AA SH E0718-02-30 (c) A
17 83VU 1831VT 8L EN3155-016M2222 2792S7152 B 7S TK26 1000 40 83VU 1CE1-AA 9K E0170FA2200 (c) A
18 83VU 1831VT 10L EN3155-016M2222 2792S7152 R 7S TK26 1000 40 83VU 1CE1-AA 9J E0170FA2200 (c) A
19
20
21
22
23
24
25
(c) = BUNDLE D9000095461195 S = SAFETY WIRE
A = ADDED WIRE
SH = SHIELD
CONF 002
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 83VU 3411G7230 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 2792G7150 W.F. E0160-1-0H (c) A
2 83VU 2792G7150 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 2792G7152 W.F. E0160-1-0H (c) A
3 83VU 2792G7152 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 2269G7071 W.F. E0160-1-0H (c) A
4 83VU 2269G7071 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 3457G7077 W.F. E0160-1-0H (c) A
5 83VU 3457G7077 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 3452G7095 W.F. E0160-1-0H (c) A
6 83VU 3452G7095 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 3443G7065 W.F. E0160-1-0H (c) A
7 83VU 3443G7065 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 2286G7103 W.F. E0160-1-0H (c) A
8 83VU 2286G7103 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 2792G7122 W.F. E0160-1-0H (c) A
9 83VU 2792G7122 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 2792G7123 W.F. E0160-1-0H (c) A
10 83VU 2792G7123 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 3411G7230 W.F. E0160-1-0H (c) A
11 83VU 1831VT SH E0718-02-30 3411G7230 1S TK26 3500 140 85VU 1851VT SH E0718-02-30 (c) A
12 83VU 1831VT 8M EN3155-016M2222 3411S7230 B 1S TK26 3500 140 85VU 1851VT 50F EN3155-016M2222 (c) A
13 83VU 1831VT 10M EN3155-016M2222 3411S7230 R 1S TK26 3500 140 85VU 1851VT 50A EN3155-016M2222 (c) A
14 83VU 1831VT SH E0718-02-30 3443G7065 1S TK26 4000 160 82VU 1SG-AE SH E0718-02-30 (c) A
15 83VU 1831VT 8U EN3155-016M2222 3443-7065 B 1S TK26 4000 160 82VU 1SG-AE 7B E0170FA2200 (c) A
16 83VU 1831VT 10U EN3155-016M2222 3443-7065 R 1S TK26 4000 160 82VU 1SG-AE 7A E0170FA2200 (c) A
17 83VU 1831VT SH E0718-02-30 3452G7095 1S TK26 3500 140 81VU 1SH1-AA SH E0718-02-30 (c) A
18 83VU 1831VT 8X EN3155-016M2222 3452-7095 B 1S TK26 3500 140 81VU 1SH1-AA 2B E0170FA2200 (c) A
19 81VU 1SH1-AA 2A E0170FA2200 3452-7095 R 1S TK26 3500 140 83VU 1831VT 10X EN3155-016M2222 (c) A
20 83VU 1831VT SH E0718-02-30 3457G7077 1S TK26 3500 140 127 83VC SH E0718-02-30 (c) A
21 83VU 1831VT 8P EN3155-016M2222 3457-7077 B 1S TK26 3500 140 127 83VC 16 EN3155-008M2222 (c) A
22 127 83VC 13 EN3155-008M2222 3457-7077 R 1S TK26 3500 140 83VU 1831VT 10P EN3155-016M2222 (c) A
23 85VU 3162G7188 W.F. E0160-1-0H 3411S0825 1S CF24 1000 40 85VU 3411G7230 W.F. E0160-1-0H (c) A
24 85VU 3411G7230 W.F. E0160-1-0H 3411S0825 1S CF24 1000 40 127 3411G7079 W.F. E0160-1-0H (c) A
25 127 3457G7077 W.F. E0160-1-0H 3457-0071 1S CF24 500 20 127 83VC 17 EN3155-008M2222 (c) A
(c) = BUNDLE D9000095461195 W.F. = WIRE FERRULE
A = ADDED WIRE S = SAFETY WIRE
SH = SHIELD
CONF 002
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 85VU 1WT3-AA SH E0718-02-30 3162G7188 1S TK26 85VU 1851VT SH E0718-02-30 F.R.
2 85VU 1WT3-AA 5D 3162-7188 B 1S TK26 85VU 1851VT 50E F.R.
3 85VU 1851VT 50R 3162-7188 R 1S TK26 85VU 1WT3-AA 5C F.R.
4 127 151VC SH E0718-02-30 3411G7079 1S TK26 85VU 1851VT SH E0718-02-30 F.R.
5 127 151VC 14 3411S7079 B 1S TK26 85VU 1851VT 50M F.R.
6 127 151VC 13 3411S7079 R 1S TK26 85VU 1851VT 50H F.R.
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
F.R. = FOR REFERENCE
SH = SHIELD
S = SAFETY WIRE
CONF 002
BEFORE
0820 S
AB 10
4K B M
2269-7069 V
4J R
E
X
1CC2
FAC-2 F
84VU Y
128
AB
P
AD B 4K
2286-7107
5G B S G R 4J
2792-7116
5F R S
D 1CA2
FMGC-2
2CE2 8S 84VU
ELAC-2 N 128
84VU
128
U
L
8S
AD
B S 9B
2792-7142
B R S 9A
AA
K
B S 9K
2792-7144
A R S 9J
C 1CE2
7 0443 S SEC-2
6 B S 84VU
F.R. 7142 T 128
5 R S
A 42VC H
128 S 36
0458
J
R 7090 B
F.R. F.R.
TK24 R
P R
B S 35
A 198VC 7091
188VU S R S 34
128
1840VT 152VC A
128 128
84VU
DELETED WIRE F.R. FOR REFERENCE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 3411
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK26 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 2S
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-34XX1620-A-FAPE3-00MG7-A-002-01
CONF 002
AFTER
0820 S
10 AA
X B 2B
AB V 3452-7090
R 2A
4K B M
2269-7069 Y
4J R 1SH2
E XPDR
ATC-2
1CC2 FAC-2 82VU
84VU 128 F 128
AD 8S AB
P
5G B S B 4K
2792-7116 2286-7107
5F R S G R 4J
L
8S
12
AD
X
B S 9B
V 2792-7142
E R S 9A
Y AA
F
B S 9K
2792-7144
7 0443 S D R S 9J
F.R. 6 B S
7142 M 1CE2
5 R S SEC-2
84VU
A 42VC U 128
128
R B N
F.R. 7090
TK24 S 36
P R
0458
P
A 198VC
128 188VU
G
B S 35
7091
L R S 34
1840VT 152VC A
128 128
84VU
NEW WIRE F.R. FOR REFERENCE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 3411
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK26 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 2S
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-34XX1620-A-FAPE3-00MG8-A-002-01
CONF 002
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 84VU 1840VT SH 2269G7069 2S TK26 84VU 1CC2-AB SH D
2 84VU 1840VT 10M 2269-7069 B 2S TK26 84VU 1CC2-AB 4K D
3 84VU 1840VT 10C 2269-7069 R 2S TK26 84VU 1CC2-AB 4J D
4 84VU 1840VT SH 2286G7107 2S TK26 84VU 1CA2-AB SH D
5 84VU 1840VT 10F 2286-7107 B 2S TK26 84VU 1CA2-AB 4K D
6 84VU 1840VT 10K 2286-7107 R 2S TK26 84VU 1CA2-AB 4J D
7 84VU 1840VT SH 2792G7116 8S TK26 84VU 2CE2-AD SH D
8 84VU 1840VT 10P 2792S7116 B 8S TK26 84VU 2CE2-AD 5G D
9 84VU 1840VT 10J 2792S7116 R 8S TK26 84VU 2CE2-AD 5F D
10 84VU 1840VT SH 2792G7142 8S TK26 84VU 1CE2-AD SH D
11 84VU 1840VT 10E 2792S7142 B 8S TK26 84VU 1CE2-AD 9B D
12 84VU 1840VT 10B 2792S7142 R 8S TK26 84VU 1CE2-AD 9A D
13 84VU 1840VT SH 2792G7144 8S TK26 84VU 1CE2-AA SH D
14 84VU 1840VT 10D 2792S7144 B 8S TK26 84VU 1CE2-AA 9K D
15 84VU 1840VT 10A 2792S7144 R 8S TK26 84VU 1CE2-AA 9J D
16 188VU 3411G7090 W.F. 3411S0820 2S CF24 128 3411G7091 W.F. D
17 128 3411G7091 W.F. 3411S0820 2S CF24 84VU 2792G7144 W.F. D
18 84VU 2792G7144 W.F. 3411S0820 2S CF24 84VU 2792G7142 W.F. D
19 84VU 2792G7142 W.F. 3411S0820 2S CF24 84VU 2286G7107 W.F. D
20 84VU 2286G7107 W.F. 3411S0820 2S CF24 84VU 2269G7069 W.F. D
21 84VU 2269G7069 W.F. 3411S0820 2S CF24 84VU 2792G7116 W.F. D
22 84VU 2792G7116 W.F. 3411S0820 2S CF24 128 3411G7142 W.F. D
23 128 3411G7142 W.F. 3411S0820 2S CF24 188VU 3411G7090 W.F. D
24
25
D = DELETED WIRE S = SAFETY WIRE
SH = SHIELD
W.F. = WIRE FERRULE
CONF 002
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 84VU 1840VT SH 3411G7090 2S TK24 188VU 198VC SH D
2 84VU 1840VT 10G 3411-7090 B 2S TK24 188VU 198VC R D
3 84VU 1840VT 10R 3411-7090 R 2S TK24 188VU 198VC P D
4 84VU 1840VT SH 3411G7091 2S TK26 128 152VC SH D
5 84VU 1840VT 10L 3411S7091 B 2S TK26 128 152VC 35 D
6 84VU 1840VT 10S 3411S7091 R 2S TK26 128 152VC 34 D
7 84VU 1840VT SH 3411G7142 2S TK26 128 42VC SH D
8 84VU 1840VT 10N 3411S7142 B 2S TK26 128 42VC 6 D
9 84VU 1840VT 10H 3411S7142 R 2S TK26 128 42VC 5 D
10 84VU 3411G7091 W.F. 3411S0458 2S CF24 128 152VC 36 D
11 128 3411G7142 W.F. 3411S0443 2S CF24 128 42VC 7 D
12
13
14
15
16
17
18
19
20
21
22
23
24
25
D = DELETED WIRE S = SAFETY WIRE
SH = SHIELD
W.F. = WIRE FERRULE
CONF 002
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 84VU 1840VT SH E0718-02-30 2269G7069 2S TK26 1000 40 84VU 1CC2-AB SH E0718-02-30 (c) A
2 84VU 1840VT 10M EN3155-016M2222 2269-7069 B 2S TK26 1000 40 84VU 1CC2-AB 4K E0170FA2200 (c) A
3 84VU 1840VT 12M EN3155-016M2222 2269-7069 R 2S TK26 1000 40 84VU 1CC2-AB 4J E0170FA2200 (c) A
4 84VU 1840VT SH E0718-02-30 2286G7107 2S TK26 1500 60 84VU 1CA2-AB SH E0718-02-30 (c) A
5 84VU 1840VT 10F EN3155-016M2222 2286-7107 B 2S TK26 1500 60 84VU 1CA2-AB 4K E0170FA2200 (c) A
6 84VU 1840VT 12F EN3155-016M2222 2286-7107 R 2S TK26 1500 60 84VU 1CA2-AB 4J E0170FA2200 (c) A
7 84VU 1840VT SH E0718-02-30 2792G7116 8S TK26 2500 100 84VU 2CE2-AD SH E0718-02-30 (c) A
8 84VU 1840VT 10P EN3155-016M2222 2792S7116 B 8S TK26 2500 100 84VU 2CE2-AD 5G E0170FA2200 (c) A
9 84VU 1840VT 12P EN3155-016M2222 2792S7116 R 8S TK26 2500 100 84VU 2CE2-AD 5F E0170FA2200 (c) A
10 84VU 1840VT SH E0718-02-30 2792G7142 8S TK26 2000 80 84VU 1CE2-AD SH E0718-02-30 (c) A
11 84VU 1840VT 10E EN3155-016M2222 2792S7142 B 8S TK26 2000 80 84VU 1CE2-AD 9B E0170FA2200 (c) A
12 84VU 1840VT 12E EN3155-016M2222 2792S7142 R 8S TK26 2000 80 84VU 1CE2-AD 9A E0170FA2200 (c) A
13 84VU 1840VT SH E0718-02-30 2792G7144 8S TK26 2000 80 84VU 1CE2-AA SH E0718-02-30 (c) A
14 84VU 1840VT 10D EN3155-016M2222 2792S7144 B 8S TK26 2000 80 84VU 1CE2-AA 9K E0170FA2200 (c) A
15 84VU 1840VT 12D EN3155-016M2222 2792S7144 R 8S TK26 2000 80 84VU 1CE2-AA 9J E0170FA2200 (c) A
16 84VU 1840VT SH E0718-02-30 3411G7090 2S TK24 6000 240 188VU 198VC SH E0718-02-30 (c) A
17 84VU 1840VT 10G EN3155-016M2222 3411-7090 B 2S TK24 6000 240 188VU 198VC R EN3155-019F2018 (c) A
18 84VU 1840VT 12G EN3155-016M2222 3411-7090 R 2S TK24 6000 240 188VU 198VC P EN3155-019F2018 (c) A
19 84VU 1840VT SH E0718-02-30 3411G7091 2S TK26 4000 160 128 152VC SH E0718-02-30 (c) A
20 84VU 1840VT 10L EN3155-016M2222 3411S7091 B 2S TK26 4000 160 128 152VC 35 EN3155-008M2222 (c) A
21 84VU 1840VT 12L EN3155-016M2222 3411S7091 R 2S TK26 4000 160 128 152VC 34 EN3155-008M2222 (c) A
22 84VU 1840VT SH E0718-02-30 3411G7142 2S TK26 2000 80 128 42VC SH E0718-02-30 (c) A
23 84VU 1840VT 10N EN3155-016M2222 3411S7142 B 2S TK26 2000 80 128 42VC 6 EN3155-008M2222 (c) A
24 84VU 1840VT 12N EN3155-016M2222 3411S7142 R 2S TK26 2000 80 128 42VC 5 EN3155-008M2222 (c) A
25
(c) = BUNDLE D9000095461195 S = SAFETY WIRE
A = ADDED WIRE
SH = SHIELD
CONF 002
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 84VU 1840VT SH E0718-02-30 3452G7090 2S TK26 2500 100 82VU 1SH2-AA SH E0718-02-30 (c) A
2 84VU 1840VT 10X EN3155-016M2222 3452-7090 B 2S TK26 2500 100 82VU 1SH2-AA 2B E0170FA2200 (c) A
3 82VU 1SH2-AA 2A E0170FA2200 3452-7090 R 2S TK26 2500 100 84VU 1840VT 12X EN3155-016M2222 (c) A
4 84VU 3411G7091 W.F. E0160-1-0H 3411S0458 2S CF24 500 20 128 152VC 36 EN3155-008M2222 (c) A
5 128 3411G7091 W.F. E0160-1-0H 3411S0820 2S CF24 4500 180 84VU 2792G7144 W.F. E0160-1-0H (c) A
6 84VU 2792G7144 W.F. E0160-1-0H 3411S0820 2S CF24 4500 180 84VU 2792G7142 W.F. E0160-1-0H (c) A
7 84VU 2792G7142 W.F. E0160-1-0H 3411S0820 2S CF24 4500 180 84VU 2286G7107 W.F. E0160-1-0H (c) A
8 84VU 2286G7107 W.F. E0160-1-0H 3411S0820 2S CF24 4500 180 84VU 3452G7090 W.F. E0160-1-0H (c) A
9 84VU 3411G7090 W.F. E0160-1-0H 3411S0820 2S CF24 4500 180 128 3411G7091 W.F. E0160-1-0H (c) A
10 84VU 2792G7116 W.F. E0160-1-0H 3411S0820 2S CF24 4500 180 84VU 3411G7142 W.F. E0160-1-0H (c) A
11 84VU 3411G7142 W.F. E0160-1-0H 3411S0820 2S CF24 4500 180 84VU 3411G7090 W.F. E0160-1-0H (c) A
12 84VU 3452G7090 W.F. E0160-1-0H 3411S0820 2S CF24 4500 180 84VU 2269G7069 W.F. E0160-1-0H (c) A
13 84VU 2269G7069 W.F. E0160-1-0H 3411S0820 2S CF24 4500 180 84VU 2792G7116 W.F. E0160-1-0H (c) A
14 128 42VC 7 E0160-1-0H 3411S0443 2S CF24 500 20 128 3411G7142 W.F. EN3155-008M2222 (c) A
15
16
17
18
19
20
21
22
23
24
25
(c) = BUNDLE D9000095461195 W.F. = WIRE FERRULE
A = ADDED WIRE S = SAFETY WIRE
SH = SHIELD
CONF 002
BEFORE
29
AE
8A R B
3152-7145
8B B
S
1WW2 FWC-2
86VU
128 A
AA
K R 2F
3161-7167
B 2G
R
1WT3
C DMC-3
85VU
127
T
AA
J R 2F
13 3161-7170
B 2G
3411-0301
V
1WT2
E DMC-2
F.R. 86VU
128
P
M
14 R
3411-7171
20 B Y
L AA
A 152VC
128 R 9C
3448-7068
X B 9D
15 R
7194
16 B G 1WZ
GPWC
17 0349 88VU
D 128
F.R. AB
U
R 5J
13 0450 7195
F B 5K
11 R
7233
12 B N 1CA2
FMGC-2
A 36VC 1860VT 84VU
128 128 128
86VU
0354
DELETED WIRE F.R. FOR REFERENCE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 2286
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK26 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 2S
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-34XX1620-A-FAPE3-00MG9-A-002-01
CONF 002
AFTER
36 AB
D R 3F
AE 3452-7081
B 3G
8A R P
3152-7145 AA
8B B
E R 7A
3452-7082
1WW2 FWC-2 B 7B
86VU V
128
X 1SH2
XPDR
ATC-2
L 82VU 128
AA
F R 2F
Y 3161-7167
B 2G
N
1WT3
M DMC-3
85VU
127
U
AA
G R 2F
13 3161-7170
37 B 2G
D
3411-0301
1WT2
E DMC-2
F.R. 86VU
128
P
14 R
3411-7171 F
20 B
A 152VC AA
G
128 R 9C
3448-7068
U B 9D
15 R
7194 Y
16 B L 1WZ
GPWC
17 0349 88VU
X 128
AB
F.R. V
R 5J
13 0450 7195
M B 5K
11 R
7233
12 B N 1CA2
FMGC-2
A 36VC 1860VT 84VU
128 128 86VU 128
0354
NEW WIRE F.R. FOR REFERENCE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 2286
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK26 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 2S
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-34XX1620-A-FAPE3-00MGA-A-002-01
CONF 002
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 86VU 1860VT SH 3152G7145 2S TK26 86VU 1WW2-AE SH D
2 86VU 1860VT 29E 3152-7145 B 2S TK26 86VU 1WW2-AE 8B D
3 86VU 1860VT 29B 3152-7145 R 2S TK26 86VU 1WW2-AE 8A D
4 86VU 1860VT SH 3161G7170 2S TK26 86VU 1WT2-AA SH D
5 86VU 1860VT 29L 3161-7170 B 2S TK26 86VU 1WT2-AA 2G D
6 86VU 1860VT 29J 3161-7170 R 2S TK26 86VU 1WT2-AA 2F D
7 86VU 3152G7145 W.F. 2286-0354 2S CF24 86VU 3411G7171 W.F. D
8 86VU 3411G7171 W.F. 2286-0354 2S CF24 128 2286G7194 W.F. D
9 128 2286G7194 W.F. 2286-0354 2S CF24 128 2286G7233 W.F. D
10 128 2286G7233 W.F. 2286-0354 2S CF24 84VU 2286G7195 W.F. D
11 84VU 2286G7195 W.F. 2286-0354 2S CF24 88VU 3448G7068 W.F. D
12 88VU 3448G7068 W.F. 2286-0354 2S CF24 86VU 3161G7170 W.F. D
13 86VU 3161G7170 W.F. 2286-0354 2S CF24 86VU 3161G7167 W.F. D
14 86VU 3161G7167 W.F. 2286-0354 2S CF24 86VU 3152G7145 W.F. D
15 86VU 1860VT SH 2286G7194 2S TK26 128 36VC SH D
16 86VU 1860VT 29G 2286-7194 B 2S TK26 128 36VC 16 D
17 86VU 1860VT 29H 2286-7194 R 2S TK26 128 36VC 15 D
18 86VU 1860VT SH 2286G7195 2S TK26 84VU 1CA2-AB SH D
19 86VU 1860VT 29F 2286-7195 B 2S TK26 84VU 1CA2-AB 5K D
20 86VU 1860VT 29C 2286-7195 R 2S TK26 84VU 1CA2-AB 5J D
21 86VU 1860VT SH 2286G7233 2S TK26 128 36VC SH D
22 86VU 1860VT 29N 2286-7233 B 2S TK26 128 36VC 12 D
23 86VU 1860VT 29R 2286-7233 R 2S TK26 128 36VC 11 D
24
25
D = DELETED WIRE
SH = SHIELD
W.F. = WIRE FERRULE
CONF 002
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 86VU 1860VT SH 3161G7167 2S TK26 85VU 1WT3-AA SH D
2 85VU 1WT3-AA 2G 3161-7167 B 2S TK26 86VU 1860VT 29M D
3 86VU 1860VT 29K 3161-7167 R 2S TK26 85VU 1WT3-AA 2F D
4 86VU 1860VT SH 3411G7171 2S TK26 128 152VC SH D
5 86VU 1860VT 29D 3411-7171 B 2S TK26 128 152VC 20 D
6 86VU 1860VT 29A 3411-7171 R 2S TK26 128 152VC 14 D
7 86VU 1860VT SH 3448G7068 2S TK26 88VU 1WZ-AA SH D
8 88VU 1WZ-AA 9D 3448-7068 B 2S TK26 86VU 1860VT 29X D
9 86VU 1860VT 29T 3448-7068 R 2S TK26 88VU 1WZ-AA 9C D
10 86VU 2286G7194 W.F. 2286-0349 2S CF24 128 36VC 17 D
11 86VU 2286G7233 W.F. 2286-0450 2S CF24 128 36VC 13 D
12 128 3411G7171 W.F. 3411-0301 2S CF24 128 152VC 13 D
13
14
15
16
17
18
19
20
21
22
23
24
25
D = DELETED WIRE
SH = SHIELD
W.F. = WIRE FERRULE
CONF 002
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 86VU 1860VT SH E0718-02-30 3152G7145 2S TK26 1500 60 86VU 1WW2-AE SH E0718-02-30 (c) A (b) (d)(1)
2 86VU 1860VT 37P EN3155-016M2222 3152-7145 B 2S TK26 1500 60 86VU 1WW2-AE 8B E0170FA2200 (c) A (b) (d)(1)
3 86VU 1860VT 36P EN3155-016M2222 3152-7145 R 2S TK26 1500 60 86VU 1WW2-AE 8A E0170FA2200 (c) A (b) (d)(1)
4 86VU 1860VT SH E0718-02-30 3161G7170 2S TK26 1000 40 86VU 1WT2-AA SH E0718-02-30 (c) A (b) (d)(1)
5 86VU 1860VT 37G EN3155-016M2222 3161-7170 B 2S TK26 1000 40 86VU 1WT2-AA 2G E0170FA2200 (c) A (b) (d)(1)
6 86VU 1860VT 36G EN3155-016M2222 3161-7170 R 2S TK26 1000 40 86VU 1WT2-AA 2F E0170FA2200 (c) A (b) (d)(1)
7 86VU 3152G7145 W.F. E0160-1-0H 2286-0354 2S CF24 5000 200 128 3411G7171 W.F. E0160-1-0H (c) A (b) (d)(1)
8 128 3411G7171 W.F. E0160-1-0H 2286-0354 2S CF24 5000 200 128 2286G7194 W.F. E0160-1-0H (c) A (b) (d)(1)
9 128 2286G7194 W.F. E0160-1-0H 2286-0354 2S CF24 5000 200 86VU 2286G7233 W.F. E0160-1-0H (c) A (b) (d)(1)
10 86VU 2286G7233 W.F. E0160-1-0H 2286-0354 2S CF24 5000 200 84VU 2286G7195 W.F. E0160-1-0H (c) A (b) (d)(1)
11 84VU 2286G7195 W.F. E0160-1-0H 2286-0354 2S CF24 5000 200 88VU 3448G7068 W.F. E0160-1-0H (c) A (b) (d)(1)
12 88VU 3448G7068 W.F. E0160-1-0H 2286-0354 2S CF24 5000 200 86VU 3161G7170 W.F. E0160-1-0H (c) A (b) (d)(1)
13 86VU 3161G7170 W.F. E0160-1-0H 2286-0354 2S CF24 5000 200 86VU 3161G7167 W.F. E0160-1-0H (c) A (b) (d)(1)
14 86VU 3161G7167 W.F. E0160-1-0H 2286-0354 2S CF24 5000 200 86VU 3452G7082 W.F. E0160-1-0H (c) A (b) (d)(1)
15 86VU 3452G7082 W.F. E0160-1-0H 2286-0354 2S CF24 5000 200 86VU 3452G7081 W.F. E0160-1-0H (c) A (b) (d)(1)
16 86VU 3452G7081 W.F. E0160-1-0H 2286-0354 2S CF24 5000 200 86VU 3152G7145 W.F. E0160-1-0H (c) A (b) (d)(1)
17 86VU 1860VT SH E0718-02-30 2286G7194 2S TK26 3000 120 128 36VC SH E0718-02-30 (c) A (b) (d)(1)
18 86VU 1860VT 37L EN3155-016M2222 2286-7194 B 2S TK26 3000 120 128 36VC 16 EN3155-008M2222 (c) A (b) (d)(1)
19 86VU 1860VT 36L EN3155-016M2222 2286-7194 R 2S TK26 3000 120 128 36VC 15 EN3155-008M2222 (c) A (b) (d)(1)
20 86VU 1860VT SH E0718-02-30 2286G7195 2S TK26 3000 120 84VU 1CA2-AB SH E0718-02-30 (c) A (b) (d)(1)
21 86VU 1860VT 37M EN3155-016M2222 2286-7195 B 2S TK26 3000 120 84VU 1CA2-AB 5K E0170FA2200 (c) A (b) (d)(1)
22 86VU 1860VT 36M EN3155-016M2222 2286-7195 R 2S TK26 3000 120 84VU 1CA2-AB 5J E0170FA2200 (c) A (b) (d)(1)
23 86VU 1860VT SH E0718-02-30 2286G7233 2S TK26 3000 120 128 36VC SH E0718-02-30 (c) A (b) (d)(1)
24 86VU 1860VT 37N EN3155-016M2222 2286-7233 B 2S TK26 3000 120 128 36VC 12 EN3155-008M2222 (c) A (b) (d)(1)
25 86VU 1860VT 36N EN3155-016M2222 2286-7233 R 2S TK26 3000 120 128 36VC 11 EN3155-008M2222 (c) A (b) (d)(1)
(c) = BUNDLE D9000095461195 W.F. = WIRE FERRULE (1) = (b) = D9000095460995 OR
A = ADDED WIRE (c) = D9000095461195 OR
SH = SHIELD (d) = D9000095461295
CONF 002
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 86VU 1860VT SH E0718-02-30 3161G7167 2S TK26 3000 120 85VU 1WT3-AA SH E0718-02-30 (c) A (b) (d)(1)
2 85VU 1WT3-AA 2G E0170FA2200 3161-7167 B 2S TK26 3000 120 86VU 1860VT 37F EN3155-016M2222 (c) A (b) (d)(1)
3 86VU 1860VT 36F EN3155-016M2222 3161-7167 R 2S TK26 3000 120 85VU 1WT3-AA 2F E0170FA2200 (c) A (b) (d)(1)
4 86VU 1860VT SH E0718-02-30 3411G7171 2S TK26 4500 180 128 152VC SH E0718-02-30 (c) A (b) (d)(1)
5 86VU 1860VT 37X EN3155-016M2222 3411-7171 B 2S TK26 4500 180 128 152VC 20 EN3155-008M2222 (c) A (b) (d)(1)
6 86VU 1860VT 36X EN3155-016M2222 3411-7171 R 2S TK26 4500 180 128 152VC 14 EN3155-008M2222 (c) A (b) (d)(1)
7 86VU 1860VT SH E0718-02-30 3448G7068 2S TK26 2500 100 88VU 1WZ-AA SH E0718-02-30 (c) A (b) (d)(1)
8 88VU 1WZ-AA 9D E0170FA2200 3448-7068 B 2S TK26 2500 100 86VU 1860VT 37U EN3155-016M2222 (c) A (b) (d)(1)
9 86VU 1860VT 36U EN3155-016M2222 3448-7068 R 2S TK26 2500 100 88VU 1WZ-AA 9C E0170FA2200 (c) A (b) (d)(1)
10 86VU 1860VT SH E0718-02-30 3452G7081 2S TK26 3500 140 82VU 1SH2-AB SH E0718-02-30 (c) A (b) (d)(1)
11 82VU 1SH2-AB 3G E0170FA2200 3452-7081 B 2S TK26 3500 140 86VU 1860VT 37D EN3155-016M2222 (c) A (b) (d)(1)
12 86VU 1860VT 36D EN3155-016M2222 3452-7081 R 2S TK26 3500 140 82VU 1SH2-AB 3F E0170FA2200 (c) A (b) (d)(1)
13 86VU 1860VT SH E0718-02-30 3452G7082 2S TK26 3500 140 82VU 1SH2-AA SH E0718-02-30 (c) A (b) (d)(1)
14 82VU 1SH2-AA 7B E0170FA2200 3452-7082 B 2S TK26 3500 140 86VU 1860VT 37E EN3155-016M2222 (c) A (b) (d)(1)
15 86VU 1860VT 36E EN3155-016M2222 3452-7082 R 2S TK26 3500 140 82VU 1SH2-AA 7A E0170FA2200 (c) A (b) (d)(1)
16 86VU 2286G7194 W.F. E0160-1-0H 2286-0349 2S CF24 500 20 128 36VC 17 EN3155-008M2222 (c) A (b) (d)(1)
17 86VU 3411G7171 W.F. E0160-1-0H 3411-0301 2S CF24 500 20 128 152VC 13 EN3155-008M2222 (c) A (b) (d)(1)
18 128 2286G7233 W.F. E0160-1-0H 2286-0450 2S CF24 500 20 128 36VC 13 EN3155-008M2222 (c) A (b) (d)(1)
19
20
21
22
23
24
25
(c) = BUNDLE D9000095461195 W.F. = WIRE FERRULE (1) = (b) = D9000095460995 OR
A = ADDED WIRE (c) = D9000095461195 OR
SH = SHIELD (d) = D9000095461295
CONF 002
BEFORE
41
AA F.R. V
2E B D
3161-7165 F.R. AB
2D R - F.R.
B 5B
42 3137-7066
1WT3 DMC-3 V R 5A
85VU
127 D
1TV DMU
- F.R. OR
10TV FDIMU
1851VT 87VU
127 85VU 127
0343 S
AFTER
F.R. AB
41
AA F.R. V R 5B
3137-7066
2E B D B 5A
3161-7165
2D R X
1TV DMU
Y OR
1WT3 DMC-3 10TV FDIMU
85VU - F.R. 87VU
127 127
42
V AA
D B 7B
3452-7091
X R 7A
Y AB
- F.R. B 3G
3452-7092
1851VT R 3F .
127 85VU
CONF 002
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 87VU 3137G7066 W.F. 2286S0343 1S CF24 85VU 3161G7165 W.F. D
2 85VU 3137G7066 W.F. E0160-1-0H 2286S0343 1S CF24 1500 60 81VU 3452G7091 W.F. E0160-1-0H (a) A (c) (1)
3 81VU 3452G7091 W.F. E0160-1-0H 2286S0343 1S CF24 1500 60 81VU 3452G7092 W.F. E0160-1-0H (a) A (c) (1)
4 81VU 3452G7092 W.F. E0160-1-0H 2286S0343 1S CF24 1500 60 85VU 3161G7165 W.F. E0160-1-0H (a) A (c) (1)
5 81VU 1SH1-AA SH E0718-02-30 3452G7091 1S TK26 4000 160 85VU 1851VT SH E0718-02-30 (a) A (c) (1)
6 81VU 1SH1-AA 7B E0170FA2200 3452-7091 B 1S TK26 4000 160 85VU 1851VT 41X EN3155-016M2222 (a) A (c) (1)
7 81VU 1SH1-AA 7A E0170FA2200 3452-7091 R 1S TK26 4000 160 85VU 1851VT 42X EN3155-016M2222 (a) A (c) (1)
8 81VU 1SH1-AB SH E0718-02-30 3452G7092 1S TK26 4000 160 85VU 1851VT SH E0718-02-30 (a) A (c) (1)
9 81VU 1SH1-AB 3G E0170FA2200 3452-7092 B 1S TK26 4000 160 85VU 1851VT 41Y EN3155-016M2222 (a) A (c) (1)
10 81VU 1SH1-AB 3F E0170FA2200 3452-7092 R 1S TK26 4000 160 85VU 1851VT 42Y EN3155-016M2222 (a) A (c) (1)
11
12
13
14 87VU 1TV-AB SH E0718-02-30 3137G7066 1S TK26 85VU 1851VT SH E0718-02-30 F.R.
15 87VU 1TV-AB 5B 3137-7066 B 1S TK26 85VU 1851VT 41V F.R.
16 85VU 1851VT 42V 3137-7066 R 1S TK26 87VU 1TV-AB 5A F.R.
17 85VU 1WT3-AA SH E0718-02-30 3161G7165 1S TK26 85VU 1851VT SH E0718-02-30 F.R.
18 85VU 1WT3-AA 2E 3161-7165 B 1S TK26 85VU 1851VT 41D F.R.
19 85VU 1WT3-AA 2D 3161-7165 R 1S TK26 85VU 1851VT 42D F.R.
20
21
22
23
24
25
(a) = BUNDLE D9000095460895 F.R. = FOR REFERENCE S = SAFETY WIRE
A = ADDED WIRE SH = SHIELD (1) = (a) = D9000095460895 OR
D = DELETED WIRE W.F. = WIRE FERRULE (c) = D9000095461195
CONF 003
(1) Task A320-A-34-XX-1620-01003-920A-A - Modify the Equipment and the
Wiring in the Aft Electronics Rack 80VU
Job Set-Up Information
Working Area
Man-hours 47.00 h
Minimum Number of person 1
Elapsed Time 47.00 h
Material necessary to do the job
Part kit 341620A02R00
ITEM PART No. QTY (UM) KEYWORD DRAWING SEE NOTES
D9000095460895 1 BUNDLE
Manuals/Drawings References/Sheets
Task 22-66-34-000-002
Task 22-66-34-400-002
AMM
Task 22-83-34-000-001
Task 22-83-34-400-001
Manuals/Drawings References/Sheets
Task 27-93-34-000-001
Task 27-93-34-400-001
Task 27-94-34-000-001
Task 27-94-34-400-001
Task 31-36-34-000-001
Task 31-36-34-000-002
Task 31-36-34-400-001
Task 31-36-34-400-002
Task 31-53-34-000-001
Task 31-53-34-400-001
Task 31-63-34-000-001
Task 31-63-34-400-001
Task 34-43-34-000-001
Task 34-43-34-400-001
Task 34-48-34-000-001
Task 34-48-34-400-001
Task 34-52-33-000-001
Task 34-52-33-400-001
20-33-00
20-33-44
ESPM
20-52-21
20-56-51
Procedure
(a) Standard Practices:
1 For the general installation of electrical wire harnesses, refer to Ref. ESPM
20-33-00.
2 For the cable tie application and tooling, refer to Ref. ESPM 20-33-44 and
Ref. ESPM 20-56-51.
3 Tag all the parts you must remove and retain to make the subsequent
installation easier.
4 Put all the retained hardware in identified plastic bags and attach the bags
to the related unit.
5 To install new wires, cut them to the necessary length, attach the terminals
and connect them.
(b) Remove and retain the FMGCs ( FIN 1CA1 and FIN 1CA2), refer to Ref. AMM Task
22-83-34-000-001.
(c) Remove and retain the FACs ( FIN 1CC1 and FIN 1CC2), refer to Ref. AMM Task
22-66-34-000-002.
(d) Remove and retain the SECs ( FIN 1CE1 and FIN 1CE2), refer to Ref. AMM Task
27-94-34-000-001.
(e) Remove and retain the ELACs ( FIN 2CE1 and FIN 2CE2), refer to Ref. AMM Task
27-93-34-000-001.
(f) Remove and retain the FWC ( FIN 1WW2), refer to Ref. AMM Task
31-53-34-000-001.
(g) Remove and retain the DMCs ( FIN 1WT2 and FIN 1WT3), refer to Ref. AMM Task
31-63-34-000-001.
(h) Remove and retain the ATC/Mode S Transponders ( FIN 1SH1 and FIN 1SH2), refer
to Ref. AMM Task 34-52-33-000-001.
(i) Remove and retain the TCAS ( FIN 1SG), refer to Ref. AMM Task
34-43-34-000-001.
(j) If installed, remove and retain the DMU ( FIN 1TV), refer to Ref. AMM Task
31-36-34-000-001.
(k) If installed, remove and retain the FDIMU ( FIN 10TV), refer to Ref. AMM Task
31-36-34-000-002.
(l) Remove and retain the GPWC ( FIN 1WZ), refer to Ref. AMM Task
34-48-34-000-001.
(m) Modify the equipment in the aft electronics rack Electrical Panel 80VU
Refer to Ref. Fig. Location of the Terminal Blocks in the Aft Electronics Rack 80VU
1 Modify the terminal block FIN 1813VT in the shelf Electrical Panel 81VU
a Loosen the end clamps at each end of the terminal block.
b If necessary install at position 28:
1 MODULE-FALSE NSA937901FM
c If necessary install at position 29:
1 MODULE-FALSE NSA937901FM
d If necessary install at position 30:
FIN 1813VT30
1 MODULE NSA937901MA2206
FIN 1813VT31
1 MODULE NSA937901MA2206
1 MODULE-FALSE NSA937901FM
c Install at position 39:
FIN 1822VT39
1 MODULE NSA937901MA2206
FIN 1831VT10
1 MODULE NSA937901MA2205
FIN 1840VT12
1 MODULE NSA937901MA2205
FIN 1860VT29
1 MODULE NSA937901MA2205 Discard
c Install at position 29:
1 MODULE-FALSE NSA937901FM
d Install at position 35:
1 MODULE-FALSE NSA937901FM
e Install at position 36:
FIN 1860VT36
1 MODULE NSA937901MA2205
FIN 1860VT37
1 MODULE NSA937901MA2205
1 CLAMP-END NSA937901S
b Install at position 54:
FIN 1862VT54
1 MODULE NSA937901MA2206
1 CLAMP-END NSA937901S
(n) Modify the wiring in the aft electronics rack Electrical Panel 80VU
Refer to Ref. ESPM 20-33-00
1 Remove the wire(s) as shown on this(these) wiring diagram(s) and the
related hook-up chart(s):
- Ref. Fig. WA and Ref. Fig. HA
- Ref. Fig. WB and Ref. Fig. HB
- Ref. Fig. WC and Ref. Fig. HC
- Ref. Fig. WD and Ref. Fig. HD
- Ref. Fig. WG and Ref. Fig. HG
- Ref. Fig. WJ and Ref. Fig. HJ
- Ref. Fig. WK and Ref. Fig. HK.
2 Install the wire(s) as shown on this(these) wiring diagram(s) and the
related hook-up chart(s):
- Ref. Fig. WA and Ref. Fig. HA
- Ref. Fig. WB and Ref. Fig. HB
- Ref. Fig. WC and Ref. Fig. HC
- Ref. Fig. WD and Ref. Fig. HD
- Ref. Fig. WE and Ref. Fig. HE
- Ref. Fig. WF and Ref. Fig. HF
- Ref. Fig. WG and Ref. Fig. HG
- Ref. Fig. WH and Ref. Fig. HH
- Ref. Fig. WJ and Ref. Fig. HJ, supplied in:
1 BUNDLE D9000095460895
1 BUNDLE D9000095461295
3 Attach the wires with:
Refer to Ref. ESPM 20-33-44 and Ref. ESPM 20-56-51
CONF 003
824
A
FR24
Z120
FR1
1822VT
1813VT
1840VT
1860VT
1862VT
1831VT 1853VT
A
80VU
ICN-A320-A-34XX1620-A-FAPE3-00MEY-A-002-01
CONF 003
0338 S 17
BEFORE
3457-0071
8
AE
F.R.
7B B U
3443-7065 V
7A R
P B 16
X 3457-7077
1SG R 13
CMPTR D
TCAS Y 83VC A
82VU 127
128 E
AB
F AB
4K B
2286-7103 B 4K
4J R G 2269-7071
R 4J
1CA1 L
FMGC-1 1CC1
83VU FAC-1
127 M 83VU
127
N
AD
AA
4G B S
2792-7122 B S 9K
4F R S 2792-7152
T R S 9J
50 A
AA AD
P
2B B S B S 9B
M 2792-7123 B 2792-7150
2A R S R S 9A
F
F.R. - F.R. S
B 43 2CE1 7S 7S 1CE1
3436-7182 F.R. ELAC-1 SEC-1
S R 42 83VU H 83VU
127 127
F.R. 79VC A
127 C
J
F.R.
14 B S J
F.R. 7079
13 R S H B S
R
A 151VC 7230
127 F.R. -
A R S K
1851VT 1831VT
127 127
85VU 83VU
0825 S
DELETED WIRE F.R. FOR REFERENCE EXISTING WIRE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 3411
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK26 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 1S
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-34XX1620-A-FAPE3-00MG1-A-002-01
CONF 003
0338 S
AFTER
8 AA
X B 2B
AE 3452-7095
R 2A
7B B U
3443-7065 V
7A R 1SH1
P XPDR
Y ATC-1
1SG 81VU
CMPTR D 127
TCAS
82VU
128 E B 16
3457-7077
AB R 13
F
4K B
3457-0071
2286-7103
4J R G F.R.
1CA1 L
FMGC-1
83VU
127 M 17
83VC A
N 127
AD 10
AB
4G B S X
2792-7122 B 4K
4F R S V 2269-7071
U R 4J
50 D 1CC1
AA FAC-1
P
2B B S Y 83VU
M 2792-7123 E 127
2A R S
F
F.R. - F.R. P
B 43 2CE1 7S AA
3436-7182 F.R. ELAC-1
S R 42 83VU G B S 9K
127 2792-7152
F.R. 79VC A R S 9J
127 F
J
F.R. AD
14 B S L
F.R. 7079 B S 9B
13 R S H B S 2792-7150
N R S 9A
A 151VC 7230
127 F.R. -
A R S M 1CE1
7S SEC-1
1851VT 1831VT 83VU
127 127 127
85VU 83VU
0825 S
NEW WIRE F.R. FOR REFERENCE EXISTING WIRE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 3411
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK26 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 1S
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-34XX1620-A-FAPE3-00MG2-A-002-01
CONF 003
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 83VU 1831VT SH 2269G7071 1S TK26 83VU 1CC1-AB SH D
2 83VU 1831VT 8E 2269-7071 B 1S TK26 83VU 1CC1-AB 4K D
3 83VU 1CC1-AB 4J 2269-7071 R 1S TK26 83VU 1831VT 8B D
4 83VU 1831VT SH 2286G7103 1S TK26 83VU 1CA1-AB SH D
5 83VU 1831VT 8D 2286-7103 B 1S TK26 83VU 1CA1-AB 4K D
6 83VU 1CA1-AB 4J 2286-7103 R 1S TK26 83VU 1831VT 8A D
7 83VU 1831VT SH 2792G7122 7S TK26 83VU 2CE1-AD SH D
8 83VU 1831VT 8G 2792S7122 B 7S TK26 83VU 2CE1-AD 4G D
9 83VU 1831VT 8H 2792S7122 R 7S TK26 83VU 2CE1-AD 4F D
10 83VU 1831VT SH 2792G7123 7S TK26 83VU 2CE1-AA SH D
11 83VU 1831VT 8F 2792S7123 B 7S TK26 83VU 2CE1-AA 2B D
12 83VU 1831VT 8C 2792S7123 R 7S TK26 83VU 2CE1-AA 2A D
13 83VU 1831VT SH 2792G7150 7S TK26 83VU 1CE1-AD SH D
14 83VU 1831VT 8N 2792S7150 B 7S TK26 83VU 1CE1-AD 9B D
15 83VU 1831VT 8R 2792S7150 R 7S TK26 83VU 1CE1-AD 9A D
16 83VU 1831VT SH 2792G7152 7S TK26 83VU 1CE1-AA SH D
17 83VU 1831VT 8L 2792S7152 B 7S TK26 83VU 1CE1-AA 9K D
18 83VU 1831VT 8J 2792S7152 R 7S TK26 83VU 1CE1-AA 9J D
19
20
21
22
23
24
25
D = DELETED WIRE
SH = SHIELD
S = SAFETY WIRE
CONF 003
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 83VU 2792G7152 W.F. 3411S0338 7S CF24 83VU 2269G7071 W.F. D
2 83VU 2269G7071 W.F. 3411S0338 7S CF24 83VU 3457G7077 W.F. D
3 83VU 3457G7077 W.F. 3411S0338 7S CF24 83VU 3443G7065 W.F. D
4 83VU 3443G7065 W.F. 3411S0338 7S CF24 83VU 2286G7103 W.F. D
5 83VU 2286G7103 W.F. 3411S0338 7S CF24 83VU 2792G7122 W.F. D
6 83VU 2792G7122 W.F. 3411S0338 7S CF24 83VU 2792G7123 W.F. D
7 83VU 2792G7123 W.F. 3411S0338 7S CF24 83VU 3411G7230 W.F. D
8 83VU 3411G7230 W.F. 3411S0338 7S CF24 83VU 2792G7150 W.F. D
9 83VU 2792G7150 W.F. 3411S0338 7S CF24 83VU 2792G7152 W.F. D
10 83VU 1831VT SH 3411G7230 1S TK26 85VU 1851VT SH D
11 83VU 1831VT 8M 3411S7230 B 1S TK26 85VU 1851VT 50F D
12 83VU 1831VT 8K 3411S7230 R 1S TK26 85VU 1851VT 50A D
13 83VU 1831VT SH 3443G7065 1S TK26 82VU 1SG-AE SH D
14 83VU 1831VT 8U 3443-7065 B 1S TK26 82VU 1SG-AE 7B D
15 83VU 1831VT 8T 3443-7065 R 1S TK26 82VU 1SG-AE 7A D
16 83VU 1831VT SH 3457G7077 1S TK26 127 83VC SH D
17 83VU 1831VT 8P 3457-7077 B 1S TK26 127 83VC 16 D
18 127 83VC 13 3457-7077 R 1S TK26 83VU 1831VT 8S D
19 127 3436G7182 W.F. 3411S0825 1S CF24 85VU 3411G7230 W.F. D
20 85VU 3411G7230 W.F. 3411S0825 1S CF24 127 3411G7079 W.F. D
21 127 3457G7077 W.F. 3457-0071 1S CF24 127 83VC 17 D
22
23
24
25
D = DELETED WIRE S = SAFETY WIRE
SH = SHIELD
W.F. = WIRE FERRULE
CONF 003
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 83VU 1831VT SH E0718-02-30 2269G7071 1S TK26 2000 80 83VU 1CC1-AB SH E0718-02-30 (a) A
2 83VU 1831VT 8E EN3155-016M2222 2269-7071 B 1S TK26 2000 80 83VU 1CC1-AB 4K E0170FA2200 (a) A
3 83VU 1CC1-AB 4J E0170FA2200 2269-7071 R 1S TK26 2000 80 83VU 1831VT 10E EN3155-016M2222 (a) A
4 83VU 1831VT SH E0718-02-30 2286G7103 1S TK26 1500 60 83VU 1CA1-AB SH E0718-02-30 (a) A
5 83VU 1831VT 8D EN3155-016M2222 2286-7103 B 1S TK26 1500 60 83VU 1CA1-AB 4K E0170FA2200 (a) A
6 83VU 1CA1-AB 4J E0170FA2200 2286-7103 R 1S TK26 1500 60 83VU 1831VT 10D EN3155-016M2222 (a) A
7 83VU 1831VT SH E0718-02-30 2792G7122 7S TK26 1500 60 83VU 2CE1-AD SH E0718-02-30 (a) A
8 83VU 1831VT 8G EN3155-016M2222 2792S7122 B 7S TK26 1500 60 83VU 2CE1-AD 4G E0170FA2200 (a) A
9 83VU 1831VT 10G EN3155-016M2222 2792S7122 R 7S TK26 1500 60 83VU 2CE1-AD 4F E0170FA2200 (a) A
10 83VU 1831VT SH E0718-02-30 2792G7123 7S TK26 1500 60 83VU 2CE1-AA SH E0718-02-30 (a) A
11 83VU 1831VT 8F EN3155-016M2222 2792S7123 B 7S TK26 1500 60 83VU 2CE1-AA 2B E0170FA2200 (a) A
12 83VU 1831VT 10F EN3155-016M2222 2792S7123 R 7S TK26 1500 60 83VU 2CE1-AA 2A E0170FA2200 (a) A
13 83VU 1831VT SH E0718-02-30 2792G7150 7S TK26 1000 40 83VU 1CE1-AD SH E0718-02-30 (a) A
14 83VU 1831VT 8N EN3155-016M2222 2792S7150 B 7S TK26 1000 40 83VU 1CE1-AD 9B E0170FA2200 (a) A
15 83VU 1831VT 10N EN3155-016M2222 2792S7150 R 7S TK26 1000 40 83VU 1CE1-AD 9A E0170FA2200 (a) A
16 83VU 1831VT SH E0718-02-30 2792G7152 7S TK26 1000 40 83VU 1CE1-AA SH E0718-02-30 (a) A
17 83VU 1831VT 8L EN3155-016M2222 2792S7152 B 7S TK26 1000 40 83VU 1CE1-AA 9K E0170FA2200 (a) A
18 83VU 1831VT 10L EN3155-016M2222 2792S7152 R 7S TK26 1000 40 83VU 1CE1-AA 9J E0170FA2200 (a) A
19
20
21
22
23
24
25
(a) = BUNDLE D9000095460895 S = SAFETY WIRE
A = ADDED WIRE
SH = SHIELD
CONF 003
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 83VU 2269G7071 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 3457G7077 W.F. E0160-1-0H (a) A
2 83VU 3457G7077 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 3452G7095 W.F. E0160-1-0H (a) A
3 83VU 3452G7095 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 3443G7065 W.F. E0160-1-0H (a) A
4 83VU 3443G7065 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 2286G7103 W.F. E0160-1-0H (a) A
5 83VU 2286G7103 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 2792G7122 W.F. E0160-1-0H (a) A
6 83VU 2792G7122 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 2792G7123 W.F. E0160-1-0H (a) A
7 83VU 2792G7123 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 3411G7230 W.F. E0160-1-0H (a) A
8 83VU 3411G7230 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 2792G7150 W.F. E0160-1-0H (a) A
9 83VU 2792G7150 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 2792G7152 W.F. E0160-1-0H (a) A
10 83VU 2792G7152 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 2269G7071 W.F. E0160-1-0H (a) A
11 83VU 1831VT SH E0718-02-30 3411G7230 1S TK26 3500 140 85VU 1851VT SH E0718-02-30 (a) A
12 83VU 1831VT 8M EN3155-016M2222 3411S7230 B 1S TK26 3500 140 85VU 1851VT 50F EN3155-016M2222 (a) A
13 83VU 1831VT 10M EN3155-016M2222 3411S7230 R 1S TK26 3500 140 85VU 1851VT 50A EN3155-016M2222 (a) A
14 83VU 1831VT SH E0718-02-30 3443G7065 1S TK26 4000 160 82VU 1SG-AE SH E0718-02-30 (a) A
15 83VU 1831VT 8U EN3155-016M2222 3443-7065 B 1S TK26 4000 160 82VU 1SG-AE 7B E0170FA2200 (a) A
16 83VU 1831VT 10U EN3155-016M2222 3443-7065 R 1S TK26 4000 160 82VU 1SG-AE 7A E0170FA2200 (a) A
17 83VU 1831VT SH E0718-02-30 3452G7095 1S TK26 3500 140 81VU 1SH1-AA SH E0718-02-30 (a) A
18 83VU 1831VT 8X EN3155-016M2222 3452-7095 B 1S TK26 3500 140 81VU 1SH1-AA 2B E0170FA2200 (a) A
19 81VU 1SH1-AA 2A E0170FA2200 3452-7095 R 1S TK26 3500 140 83VU 1831VT 10X EN3155-016M2222 (a) A
20 83VU 1831VT SH E0718-02-30 3457G7077 1S TK26 3500 140 127 83VC SH E0718-02-30 (a) A
21 83VU 1831VT 8P EN3155-016M2222 3457-7077 B 1S TK26 3500 140 127 83VC 16 EN3155-008M2222 (a) A
22 127 83VC 13 EN3155-008M2222 3457-7077 R 1S TK26 3500 140 83VU 1831VT 10P EN3155-016M2222 (a) A
23 127 3436G7182 W.F. E0160-1-0H 3411S0825 1S CF24 1000 40 85VU 3411G7230 W.F. E0160-1-0H (a) A
24 85VU 3411G7230 W.F. E0160-1-0H 3411S0825 1S CF24 1000 40 127 3411G7079 W.F. E0160-1-0H (a) A
25 127 3457G7077 W.F. E0160-1-0H 3457-0071 1S CF24 500 20 127 83VC 17 EN3155-008M2222 (a) A
(a) = BUNDLE D9000095460895 W.F. = WIRE FERRULE
A = ADDED WIRE S = SAFETY WIRE
SH = SHIELD
CONF 003
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 127 151VC SH E0718-02-30 3411G7079 1S TK26 85VU 1851VT SH E0718-02-30 F.R.
2 127 151VC 14 3411S7079 B 1S TK26 85VU 1851VT 50M F.R.
3 127 151VC 13 3411S7079 R 1S TK26 85VU 1851VT 50H F.R.
4 127 79VC SH E0718-02-30 3436G7182 1S TK26 85VU 1851VT SH E0718-02-30 F.R.
5 127 79VC 43 3436-7182 B 1S TK26 85VU 1851VT 50P F.R.
6 85VU 1851VT 50S 3436-7182 R 1S TK26 127 79VC 42 F.R.
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
F.R. = FOR REFERENCE
SH = SHIELD
S = SAFETY WIRE
CONF 003
BEFORE
0820 S
AB 10
4K B M
2269-7069 V
4J R
E
X
1CC2
FAC-2 F
84VU Y
128
AB
P
AD B 4K
2286-7107
5G B S G R 4J
2792-7116
5F R S
D 1CA2
FMGC-2
2CE2 8S 84VU
ELAC-2 N 128
84VU
128
U
44
L
3436-0337
8S
AD
B S 9B
2792-7142
F.R. B R S 9A
43 B AA
3436-7172 K
42 R B S 9K
2792-7144
A 36VC A R S 9J
128
C 1CE2
7 0443 S SEC-2
F.R. 6 B S 84VU
7142 T 128
5 R S
A 42VC H
128 S 36
0458
J
R 7090 B
F.R.
TK24 R F.R.
P R
B S 35
A 198VC 7091
188VU S R S 34
128
1840VT 152VC A
128 128
84VU
DELETED WIRE F.R. FOR REFERENCE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 3411
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK26 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 2S
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-34XX1620-A-FAPE3-00MG5-A-002-01
CONF 003
AFTER
0820 S
10 AA
X B 2B
AB V 3452-7090
R 2A
4K B M
2269-7069 Y
4J R 1SH2
E XPDR
ATC-2
1CC2 FAC-2 82VU
84VU 128 F 128
AD 8S AB
P
5G B S B 4K
2792-7116 2286-7107
5F R S G R 4J
3436-0337
U
L
F.R. 8S
12
AD
X
43 B B S 9B
3436-7172 2792-7142
42 R E R S 9A
A 36VC
128 AA
F
B S 9K
2792-7144
7 0443 S D R S 9J
6 B S V
F.R. 7142 M 1CE2
5 R S SEC-2
Y 84VU
A 42VC U 128
128
R B N
F.R. 7090
TK24 S 36
P R
0458
P
A 198VC
128 188VU
G
B S 35
7091
L R S 34
1840VT 152VC A
128 128
84VU
NEW WIRE F.R. FOR REFERENCE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 3411
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK26 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 2S
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-34XX1620-A-FAPE3-00MG6-A-002-01
CONF 003
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 84VU 1840VT SH 2269G7069 2S TK26 84VU 1CC2-AB SH D
2 84VU 1840VT 10M 2269-7069 B 2S TK26 84VU 1CC2-AB 4K D
3 84VU 1840VT 10C 2269-7069 R 2S TK26 84VU 1CC2-AB 4J D
4 84VU 1840VT SH 2286G7107 2S TK26 84VU 1CA2-AB SH D
5 84VU 1840VT 10F 2286-7107 B 2S TK26 84VU 1CA2-AB 4K D
6 84VU 1840VT 10K 2286-7107 R 2S TK26 84VU 1CA2-AB 4J D
7 84VU 1840VT SH 2792G7116 8S TK26 84VU 2CE2-AD SH D
8 84VU 1840VT 10P 2792S7116 B 8S TK26 84VU 2CE2-AD 5G D
9 84VU 1840VT 10J 2792S7116 R 8S TK26 84VU 2CE2-AD 5F D
10 84VU 1840VT SH 2792G7142 8S TK26 84VU 1CE2-AD SH D
11 84VU 1840VT 10E 2792S7142 B 8S TK26 84VU 1CE2-AD 9B D
12 84VU 1840VT 10B 2792S7142 R 8S TK26 84VU 1CE2-AD 9A D
13 84VU 1840VT SH 2792G7144 8S TK26 84VU 1CE2-AA SH D
14 84VU 1840VT 10D 2792S7144 B 8S TK26 84VU 1CE2-AA 9K D
15 84VU 1840VT 10A 2792S7144 R 8S TK26 84VU 1CE2-AA 9J D
16 84VU 3411G7142 W.F. 3411S0820 2S CF24 188VU 3411G7090 W.F. D
17 188VU 3411G7090 W.F. 3411S0820 2S CF24 128 3411G7091 W.F. D
18 128 3411G7091 W.F. 3411S0820 2S CF24 84VU 2792G7144 W.F. D
19 84VU 2792G7144 W.F. 3411S0820 2S CF24 84VU 2792G7142 W.F. D
20 84VU 2792G7142 W.F. 3411S0820 2S CF24 84VU 2286G7107 W.F. D
21 84VU 2286G7107 W.F. 3411S0820 2S CF24 84VU 2269G7069 W.F. D
22 84VU 2269G7069 W.F. 3411S0820 2S CF24 84VU 2792G7116 W.F. D
23 84VU 2792G7116 W.F. 3411S0820 2S CF24 84VU 3436G7172 W.F. D
24 84VU 3436G7172 W.F. 3411S0820 2S CF24 84VU 3411G7142 W.F. D
25
D = DELETED WIRE S = SAFETY WIRE
SH = SHIELD
W.F. = WIRE FERRULE
CONF 003
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 84VU 1840VT SH 3411G7090 2S TK24 188VU 198VC SH D
2 84VU 1840VT 10G 3411-7090 B 2S TK24 188VU 198VC R D
3 84VU 1840VT 10R 3411-7090 R 2S TK24 188VU 198VC P D
4 84VU 1840VT SH 3411G7091 2S TK26 128 152VC SH D
5 84VU 1840VT 10L 3411S7091 B 2S TK26 128 152VC 35 D
6 84VU 1840VT 10S 3411S7091 R 2S TK26 128 152VC 34 D
7 84VU 1840VT SH 3411G7142 2S TK26 128 42VC SH D
8 84VU 1840VT 10N 3411S7142 B 2S TK26 128 42VC 6 D
9 84VU 1840VT 10H 3411S7142 R 2S TK26 128 42VC 5 D
10 84VU 1840VT SH 3436G7172 2S TK26 128 36VC SH D
11 84VU 1840VT 10U 3436-7172 B 2S TK26 128 36VC 43 D
12 84VU 1840VT 10T 3436-7172 R 2S TK26 128 36VC 42 D
13 84VU 3411G7091 W.F. 3411S0458 2S CF24 128 152VC 36 D
14 128 3411G7142 W.F. 3411S0443 2S CF24 128 42VC 7 D
15 128 3436G7172 W.F. 3436-0337 2S CF24 128 36VC 44 D
16
17
18
19
20
21
22
23
24
25
D = DELETED WIRE S = SAFETY WIRE
SH = SHIELD
W.F. = WIRE FERRULE
CONF 003
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 84VU 1840VT SH E0718-02-30 2269G7069 2S TK26 1000 40 84VU 1CC2-AB SH E0718-02-30 (a) A
2 84VU 1840VT 10M EN3155-016M2222 2269-7069 B 2S TK26 1000 40 84VU 1CC2-AB 4K E0170FA2200 (a) A
3 84VU 1840VT 12M EN3155-016M2222 2269-7069 R 2S TK26 1000 40 84VU 1CC2-AB 4J E0170FA2200 (a) A
4 84VU 1840VT SH E0718-02-30 2286G7107 2S TK26 1500 60 84VU 1CA2-AB SH E0718-02-30 (a) A
5 84VU 1840VT 10F EN3155-016M2222 2286-7107 B 2S TK26 1500 60 84VU 1CA2-AB 4K E0170FA2200 (a) A
6 84VU 1840VT 12F EN3155-016M2222 2286-7107 R 2S TK26 1500 60 84VU 1CA2-AB 4J E0170FA2200 (a) A
7 84VU 1840VT SH E0718-02-30 2792G7116 8S TK26 2500 100 84VU 2CE2-AD SH E0718-02-30 (a) A
8 84VU 1840VT 10P EN3155-016M2222 2792S7116 B 8S TK26 2500 100 84VU 2CE2-AD 5G E0170FA2200 (a) A
9 84VU 1840VT 12P EN3155-016M2222 2792S7116 R 8S TK26 2500 100 84VU 2CE2-AD 5F E0170FA2200 (a) A
10 84VU 1840VT SH E0718-02-30 2792G7142 8S TK26 2000 80 84VU 1CE2-AD SH E0718-02-30 (a) A
11 84VU 1840VT 10E EN3155-016M2222 2792S7142 B 8S TK26 2000 80 84VU 1CE2-AD 9B E0170FA2200 (a) A
12 84VU 1840VT 12E EN3155-016M2222 2792S7142 R 8S TK26 2000 80 84VU 1CE2-AD 9A E0170FA2200 (a) A
13 84VU 1840VT SH E0718-02-30 2792G7144 8S TK26 2000 80 84VU 1CE2-AA SH E0718-02-30 (a) A
14 84VU 1840VT 10D EN3155-016M2222 2792S7144 B 8S TK26 2000 80 84VU 1CE2-AA 9K E0170FA2200 (a) A
15 84VU 1840VT 12D EN3155-016M2222 2792S7144 R 8S TK26 2000 80 84VU 1CE2-AA 9J E0170FA2200 (a) A
16 84VU 3411G7142 W.F. E0160-1-0H 3411S0820 2S CF24 5000 200 84VU 3411G7090 W.F. E0160-1-0H (a) A
17 84VU 3411G7090 W.F. E0160-1-0H 3411S0820 2S CF24 5000 200 128 3411G7091 W.F. E0160-1-0H (a) A
18 128 3411G7091 W.F. E0160-1-0H 3411S0820 2S CF24 5000 200 84VU 2792G7144 W.F. E0160-1-0H (a) A
19 84VU 2792G7144 W.F. E0160-1-0H 3411S0820 2S CF24 5000 200 84VU 2792G7142 W.F. E0160-1-0H (a) A
20 84VU 2792G7142 W.F. E0160-1-0H 3411S0820 2S CF24 5000 200 84VU 2286G7107 W.F. E0160-1-0H (a) A
21 84VU 2286G7107 W.F. E0160-1-0H 3411S0820 2S CF24 5000 200 84VU 3452G7090 W.F. E0160-1-0H (a) A
22 84VU 3452G7090 W.F. E0160-1-0H 3411S0820 2S CF24 5000 200 84VU 2269G7069 W.F. E0160-1-0H (a) A
23 84VU 2269G7069 W.F. E0160-1-0H 3411S0820 2S CF24 5000 200 84VU 2792G7116 W.F. E0160-1-0H (a) A
24 84VU 2792G7116 W.F. E0160-1-0H 3411S0820 2S CF24 5000 200 84VU 3436G7172 W.F. E0160-1-0H (a) A
25 84VU 3436G7172 W.F. E0160-1-0H 3411S0820 2S CF24 5000 200 84VU 3411G7142 W.F. E0160-1-0H (a) A
(a) = BUNDLE D9000095460895 W.F. = WIRE FERRULE
A = ADDED WIRE S = SAFETY WIRE
SH = SHIELD
CONF 003
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 84VU 1840VT SH E0718-02-30 3411G7090 2S TK24 6000 240 188VU 198VC SH E0718-02-30 (a) A
2 84VU 1840VT 10G EN3155-016M2222 3411-7090 B 2S TK24 6000 240 188VU 198VC R EN3155-019F2018 (a) A
3 84VU 1840VT 12G EN3155-016M2222 3411-7090 R 2S TK24 6000 240 188VU 198VC P EN3155-019F2018 (a) A
4 84VU 1840VT SH E0718-02-30 3411G7091 2S TK26 4000 160 128 152VC SH E0718-02-30 (a) A
5 84VU 1840VT 10L EN3155-016M2222 3411S7091 B 2S TK26 4000 160 128 152VC 35 EN3155-008M2222 (a) A
6 84VU 1840VT 12L EN3155-016M2222 3411S7091 R 2S TK26 4000 160 128 152VC 34 EN3155-008M2222 (a) A
7 84VU 1840VT SH E0718-02-30 3411G7142 2S TK26 2000 80 128 42VC SH E0718-02-30 (a) A
8 84VU 1840VT 10N EN3155-016M2222 3411S7142 B 2S TK26 2000 80 128 42VC 6 EN3155-008M2222 (a) A
9 84VU 1840VT 12N EN3155-016M2222 3411S7142 R 2S TK26 2000 80 128 42VC 5 EN3155-008M2222 (a) A
10 84VU 1840VT SH E0718-02-30 3436G7172 2S TK26 2000 80 128 36VC SH E0718-02-30 (a) A
11 84VU 1840VT 10U EN3155-016M2222 3436-7172 B 2S TK26 2000 80 128 36VC 43 EN3155-008M2222 (a) A
12 84VU 1840VT 12U EN3155-016M2222 3436-7172 R 2S TK26 2000 80 128 36VC 42 EN3155-008M2222 (a) A
13 84VU 1840VT SH E0718-02-30 3452G7090 2S TK26 2500 100 82VU 1SH2-AA SH E0718-02-30 (a) A
14 84VU 1840VT 10X EN3155-016M2222 3452-7090 B 2S TK26 2500 100 82VU 1SH2-AA 2B E0170FA2200 (a) A
15 82VU 1SH2-AA 2A E0170FA2200 3452-7090 R 2S TK26 2500 100 84VU 1840VT 12X EN3155-016M2222 (a) A
16 84VU 3411G7091 W.F. E0160-1-0H 3411S0458 2S CF24 500 20 128 152VC 36 EN3155-008M2222 (a) A
17 128 3411G7142 W.F. E0160-1-0H 3411S0443 2S CF24 500 20 128 42VC 7 EN3155-008M2222 (a) A
18 128 3436G7172 W.F. E0160-1-0H 3436-0337 2S CF24 500 20 128 36VC 44 EN3155-008M2222 (a) A
19
20
21
22
23
24
25
(a) = BUNDLE D9000095460895 W.F. = WIRE FERRULE
A = ADDED WIRE S = SAFETY WIRE
SH = SHIELD
CONF 003
BEFORE
29
AE
8A R B
3152-7145
8B B
1WW2 FWC-2 S
86VU
128
9
H
3441-0090
AA
K R 2F
3161-7167
F.R. B 2G
R
8 R
1WT3
3441-7072 C DMC-3
7 B 85VU
127
A 34VC T
128
AA
A
J R 2F
13 3161-7170
B 2G
3411-0301
U
1WT2
E DMC-2
F.R. 86VU
128
V
M
14 R
3411-7171
20 B P
L AA
A 152VC
128 D R 9C
3448-7068
X B 9D
15 R
7194 Y
16 B G 1WZ
GPWC
17 0349 88VU
128
F.R. AB
R 5J
13 0450 7195
F B 5K
11 R
7233
12 B N 1CA2
FMGC-2
A 36VC 1860VT 84VU
128 128 128
86VU
0354
DELETED WIRE F.R. FOR REFERENCE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 2286
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK26 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 2S
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-34XX1620-A-FAPE3-00MGB-A-002-01
CONF 003
AFTER
36 AB
D R 3F
AE 3452-7081
B 3G
8A R P
3152-7145 AA
8B B
E R 7A
Y 3452-7082
1WW2 FWC-2 B 7B
86VU V
128
X 1SH2
9 XPDR
ATC-2
3441-0090
L 82VU 128
AA
F R 2F
3161-7167
B 2G
F.R. N
8 R
1WT3
3441-7072 DMC-3
M
7 B 85VU
127
A 34VC U
128
AA
G R 2F
13 3161-7170
37 B 2G
D
3411-0301
V 1WT2
DMC-2
E 86VU
F.R. 128
P
14 R
3411-7171 F
20 B
A 152VC AA
G
128 R 9C
3448-7068
U B 9D
15 R
7194
16 B L 1WZ
GPWC
17 0349 88VU
X 128
Y AB
F.R.
R 5J
13 0450 7195
M B 5K
11 R
7233
12 B N 1CA2
FMGC-2
A 36VC 1860VT 84VU
128 128 86VU 128
0354
NEW WIRE F.R. FOR REFERENCE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 2286
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK26 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 2S
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-34XX1620-A-FAPE3-00MGC-A-002-01
CONF 003
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 86VU 1860VT SH 3152G7145 2S TK26 86VU 1WW2-AE SH D
2 86VU 1860VT 29E 3152-7145 B 2S TK26 86VU 1WW2-AE 8B D
3 86VU 1860VT 29B 3152-7145 R 2S TK26 86VU 1WW2-AE 8A D
4 86VU 1860VT SH 3161G7170 2S TK26 86VU 1WT2-AA SH D
5 86VU 1860VT 29L 3161-7170 B 2S TK26 86VU 1WT2-AA 2G D
6 86VU 1860VT 29J 3161-7170 R 2S TK26 86VU 1WT2-AA 2F D
7 86VU 3152G7145 W.F. 2286-0354 2S CF24 86VU 3441G7072 W.F. D
8 86VU 3441G7072 W.F. 2286-0354 2S CF24 86VU 3411G7171 W.F. D
9 86VU 3411G7171 W.F. 2286-0354 2S CF24 128 2286G7194 W.F. D
10 128 2286G7194 W.F. 2286-0354 2S CF24 128 2286G7233 W.F. D
11 128 2286G7233 W.F. 2286-0354 2S CF24 84VU 2286G7195 W.F. D
12 84VU 2286G7195 W.F. 2286-0354 2S CF24 88VU 3448G7068 W.F. D
13 88VU 3448G7068 W.F. 2286-0354 2S CF24 86VU 3161G7170 W.F. D
14 86VU 3161G7170 W.F. 2286-0354 2S CF24 86VU 3161G7167 W.F. D
15 86VU 3161G7167 W.F. 2286-0354 2S CF24 86VU 3152G7145 W.F. D
16 86VU 1860VT SH 2286G7194 2S TK26 128 36VC SH D
17 86VU 1860VT 29G 2286-7194 B 2S TK26 128 36VC 16 D
18 86VU 1860VT 29H 2286-7194 R 2S TK26 128 36VC 15 D
19 86VU 1860VT SH 2286G7195 2S TK26 84VU 1CA2-AB SH D
20 86VU 1860VT 29F 2286-7195 B 2S TK26 84VU 1CA2-AB 5K D
21 86VU 1860VT 29C 2286-7195 R 2S TK26 84VU 1CA2-AB 5J D
22 86VU 1860VT SH 2286G7233 2S TK26 128 36VC SH D
23 86VU 1860VT 29N 2286-7233 B 2S TK26 128 36VC 12 D
24 86VU 1860VT 29R 2286-7233 R 2S TK26 128 36VC 11 D
25
D = DELETED WIRE
SH = SHIELD
W.F. = WIRE FERRULE
CONF 003
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 86VU 1860VT SH 3161G7167 2S TK26 85VU 1WT3-AA SH D
2 85VU 1WT3-AA 2G 3161-7167 B 2S TK26 86VU 1860VT 29M D
3 86VU 1860VT 29K 3161-7167 R 2S TK26 85VU 1WT3-AA 2F D
4 86VU 1860VT SH 3411G7171 2S TK26 128 152VC SH D
5 86VU 1860VT 29D 3411-7171 B 2S TK26 128 152VC 20 D
6 86VU 1860VT 29A 3411-7171 R 2S TK26 128 152VC 14 D
7 86VU 1860VT SH 3441G7072 2S TK26 128 34VC SH D
8 86VU 1860VT 29U 3441-7072 B 2S TK26 128 34VC 7 D
9 86VU 1860VT 29S 3441-7072 R 2S TK26 128 34VC 8 D
10 86VU 1860VT SH 3448G7068 2S TK26 88VU 1WZ-AA SH D
11 88VU 1WZ-AA 9D 3448-7068 B 2S TK26 86VU 1860VT 29X D
12 86VU 1860VT 29T 3448-7068 R 2S TK26 88VU 1WZ-AA 9C D
13 86VU 2286G7194 W.F. 2286-0349 2S CF24 128 36VC 17 D
14 86VU 2286G7233 W.F. 2286-0450 2S CF24 128 36VC 13 D
15 128 3411G7171 W.F. 3411-0301 2S CF24 128 152VC 13 D
16 128 3441G7072 W.F. 3441-0090 2S CF24 128 34VC 9 D
17
18
19
20
21
22
23
24
25
D = DELETED WIRE
SH = SHIELD
W.F. = WIRE FERRULE
CONF 003
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 86VU 1860VT SH E0718-02-30 3152G7145 2S TK26 1500 60 86VU 1WW2-AE SH E0718-02-30 (d) A
2 86VU 1860VT 37P EN3155-016M2222 3152-7145 B 2S TK26 1500 60 86VU 1WW2-AE 8B E0170FA2200 (d) A
3 86VU 1860VT 36P EN3155-016M2222 3152-7145 R 2S TK26 1500 60 86VU 1WW2-AE 8A E0170FA2200 (d) A
4 86VU 1860VT SH E0718-02-30 3161G7170 2S TK26 1000 40 86VU 1WT2-AA SH E0718-02-30 (d) A
5 86VU 1860VT 37G EN3155-016M2222 3161-7170 B 2S TK26 1000 40 86VU 1WT2-AA 2G E0170FA2200 (d) A
6 86VU 1860VT 36G EN3155-016M2222 3161-7170 R 2S TK26 1000 40 86VU 1WT2-AA 2F E0170FA2200 (d) A
7 86VU 3152G7145 W.F. E0160-1-0H 2286-0354 2S CF24 5500 220 86VU 3441G7072 W.F. E0160-1-0H (d) A
8 86VU 3441G7072 W.F. E0160-1-0H 2286-0354 2S CF24 5500 220 128 3411G7171 W.F. E0160-1-0H (d) A
9 128 3411G7171 W.F. E0160-1-0H 2286-0354 2S CF24 5500 220 128 2286G7194 W.F. E0160-1-0H (d) A
10 128 2286G7194 W.F. E0160-1-0H 2286-0354 2S CF24 5500 220 86VU 2286G7233 W.F. E0160-1-0H (d) A
11 86VU 2286G7233 W.F. E0160-1-0H 2286-0354 2S CF24 5500 220 84VU 2286G7195 W.F. E0160-1-0H (d) A
12 84VU 2286G7195 W.F. E0160-1-0H 2286-0354 2S CF24 5500 220 88VU 3448G7068 W.F. E0160-1-0H (d) A
13 88VU 3448G7068 W.F. E0160-1-0H 2286-0354 2S CF24 5500 220 86VU 3161G7170 W.F. E0160-1-0H (d) A
14 86VU 3161G7170 W.F. E0160-1-0H 2286-0354 2S CF24 5500 220 86VU 3161G7167 W.F. E0160-1-0H (d) A
15 86VU 3161G7167 W.F. E0160-1-0H 2286-0354 2S CF24 5500 220 86VU 3452G7082 W.F. E0160-1-0H (d) A
16 86VU 3452G7082 W.F. E0160-1-0H 2286-0354 2S CF24 5500 220 86VU 3452G7081 W.F. E0160-1-0H (d) A
17 86VU 3452G7081 W.F. E0160-1-0H 2286-0354 2S CF24 5500 220 86VU 3152G7145 W.F. E0160-1-0H (d) A
18 86VU 1860VT SH E0718-02-30 2286G7194 2S TK26 3000 120 128 36VC SH E0718-02-30 (d) A
19 86VU 1860VT 37L EN3155-016M2222 2286-7194 B 2S TK26 3000 120 128 36VC 16 EN3155-008M2222 (d) A
20 86VU 1860VT 36L EN3155-016M2222 2286-7194 R 2S TK26 3000 120 128 36VC 15 EN3155-008M2222 (d) A
21 86VU 1860VT SH E0718-02-30 2286G7195 2S TK26 3000 120 84VU 1CA2-AB SH E0718-02-30 (d) A
22 86VU 1860VT 37M EN3155-016M2222 2286-7195 B 2S TK26 3000 120 84VU 1CA2-AB 5K E0170FA2200 (d) A
23 86VU 1860VT 36M EN3155-016M2222 2286-7195 R 2S TK26 3000 120 84VU 1CA2-AB 5J E0170FA2200 (d) A
24
25
(d) = BUNDLE D9000095461295 W.F. = WIRE FERRULE
A = ADDED WIRE
SH = SHIELD
CONF 003
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 86VU 1860VT SH E0718-02-30 2286G7233 2S TK26 3000 120 128 36VC SH E0718-02-30 (d) A
2 86VU 1860VT 37N EN3155-016M2222 2286-7233 B 2S TK26 3000 120 128 36VC 12 EN3155-008M2222 (d) A
3 86VU 1860VT 36N EN3155-016M2222 2286-7233 R 2S TK26 3000 120 128 36VC 11 EN3155-008M2222 (d) A
4 86VU 1860VT SH E0718-02-30 3161G7167 2S TK26 3000 120 85VU 1WT3-AA SH E0718-02-30 (d) A
5 85VU 1WT3-AA 2G E0170FA2200 3161-7167 B 2S TK26 3000 120 86VU 1860VT 37F EN3155-016M2222 (d) A
6 86VU 1860VT 36F EN3155-016M2222 3161-7167 R 2S TK26 3000 120 85VU 1WT3-AA 2F E0170FA2200 (d) A
7 86VU 1860VT SH E0718-02-30 3411G7171 2S TK26 4500 180 128 152VC SH E0718-02-30 (d) A
8 86VU 1860VT 37X EN3155-016M2222 3411-7171 B 2S TK26 4500 180 128 152VC 20 EN3155-008M2222 (d) A
9 86VU 1860VT 36X EN3155-016M2222 3411-7171 R 2S TK26 4500 180 128 152VC 14 EN3155-008M2222 (d) A
10 86VU 1860VT SH E0718-02-30 3441G7072 2S TK26 3000 120 128 34VC SH E0718-02-30 (d) A
11 86VU 1860VT 37V EN3155-016M2222 3441-7072 B 2S TK26 3000 120 128 34VC 7 EN3155-008M2222 (d) A
12 86VU 1860VT 36V EN3155-016M2222 3441-7072 R 2S TK26 3000 120 128 34VC 8 EN3155-008M2222 (d) A
13 86VU 1860VT SH E0718-02-30 3448G7068 2S TK26 2500 100 88VU 1WZ-AA SH E0718-02-30 (d) A
14 88VU 1WZ-AA 9D E0170FA2200 3448-7068 B 2S TK26 2500 100 86VU 1860VT 37U EN3155-016M2222 (d) A
15 86VU 1860VT 36U EN3155-016M2222 3448-7068 R 2S TK26 2500 100 88VU 1WZ-AA 9C E0170FA2200 (d) A
16 86VU 1860VT SH E0718-02-30 3452G7081 2S TK26 3500 140 82VU 1SH2-AB SH E0718-02-30 (d) A
17 82VU 1SH2-AB 3G E0170FA2200 3452-7081 B 2S TK26 3500 140 86VU 1860VT 37D EN3155-016M2222 (d) A
18 86VU 1860VT 36D EN3155-016M2222 3452-7081 R 2S TK26 3500 140 82VU 1SH2-AB 3F E0170FA2200 (d) A
19 86VU 1860VT SH E0718-02-30 3452G7082 2S TK26 3500 140 82VU 1SH2-AA SH E0718-02-30 (d) A
20 82VU 1SH2-AA 7B E0170FA2200 3452-7082 B 2S TK26 3500 140 86VU 1860VT 37E EN3155-016M2222 (d) A
21 86VU 1860VT 36E EN3155-016M2222 3452-7082 R 2S TK26 3500 140 82VU 1SH2-AA 7A E0170FA2200 (d) A
22 86VU 2286G7194 W.F. E0160-1-0H 2286-0349 2S CF24 500 20 128 36VC 17 EN3155-008M2222 (d) A
23 86VU 3411G7171 W.F. E0160-1-0H 3411-0301 2S CF24 500 20 128 152VC 13 EN3155-008M2222 (d) A
24 128 2286G7233 W.F. E0160-1-0H 2286-0450 2S CF24 500 20 128 36VC 13 EN3155-008M2222 (d) A
25 128 3441G7072 W.F. E0160-1-0H 3441-0090 2S CF24 500 20 128 34VC 9 EN3155-008M2222 (d) A
(d) = BUNDLE D9000095461295 W.F. = WIRE FERRULE
A = ADDED WIRE
SH = SHIELD
CONF 003
BEFORE
0330
34
0329
47
F.R.
32 R R
7168
33 B
A 106VC
128 AE
U R 7E
3152-7209
34 B 7F
3411-1628
T R 9C
3152-7208
F.R. B 9D
1WW2
32 R S FWC-2
3411-7418 86VU
33 B 128
A 154VC
128
B
1862VT
128
86VU
DELETED WIRE F.R. FOR REFERENCE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 3436
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK26 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 2M
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-34XX1620-A-FAPE3-00MGD-A-002-01
CONF 003
AFTER
0330
54 AA
34 A R 6H
3452-7083
0329
B 6J
F.R.
1SH2
32 R B XPDR
7168 ATC-2
33 B 82VU
128
A 106VC
128 AE
C R 7E
3152-7209
B 7F
G
D R 9C
3152-7208
B 9D
F
1WW2
E FWC-2
86VU
128
H
34
3411-1628
J
F.R.
P
32 R
3411-7418 K
33 B
A 154VC N
128
M
1862VT
128
86VU
NEW WIRE STOWED WIRE F.R. FOR REFERENCE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 3436
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK26 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 2M
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-34XX1620-A-FAPE3-00MGE-A-002-01
CONF 003
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 86VU 1WW2-AE SH 3152G7208 2M TK26 86VU 1862VT SH D
2 86VU 1WW2-AE 9D 3152-7208 B 2M TK26 86VU 1862VT 47C D
3 86VU 1WW2-AE 9C 3152-7208 R 2M TK26 86VU 1862VT 47T D
4 86VU 1WW2-AE SH 3152G7209 2M TK26 86VU 1862VT SH D
5 86VU 1WW2-AE 7F 3152-7209 B 2M TK26 86VU 1862VT 47D D
6 86VU 1WW2-AE 7E 3152-7209 R 2M TK26 86VU 1862VT 47U D
7 86VU 3436G7168 W.F. 3436-0330 2M CF24 86VU 3411G7418 W.F. D
8 86VU 3411G7418 W.F. 3436-0330 2M CF24 86VU 3152G7208 W.F. D
9 86VU 3152G7208 W.F. 3436-0330 2M CF24 86VU 3152G7209 W.F. D
10 86VU 3152G7209 W.F. 3436-0330 2M CF24 86VU 3436G7168 W.F. D
11 86VU 1862VT SH 3411G7418 2M TK26 128 154VC SH D
12 86VU 1862VT 47B 3411-7418 B 2M TK26 128 154VC 33 D
13 86VU 1862VT 47S 3411-7418 R 2M TK26 128 154VC 32 D
14 86VU 1862VT SH 3436G7168 2M TK26 128 106VC SH D
15 86VU 1862VT 47A 3436-7168 B 2M TK26 128 106VC 33 D
16 86VU 1862VT 47R 3436-7168 R 2M TK26 128 106VC 32 D
17 128 3411G7418 W.F. 3411-1628 2M CF24 128 154VC 34 D
18 128 3436G7168 W.F. 3436-0329 2M CF24 128 106VC 34 D
19
20
21
22 86VU 1WW2-AE SH E0718-02-30 3152G7208 2M TK26 2000 80 86VU 1862VT SH E0718-02-30 (a) A
23 86VU 1WW2-AE 9D E0170FA2200 3152-7208 B 2M TK26 2000 80 86VU 1862VT 54L EN3155-016M2222 (a) A
24 86VU 1WW2-AE 9C E0170FA2200 3152-7208 R 2M TK26 2000 80 86VU 1862VT 54D EN3155-016M2222 (a) A
25
(a) = BUNDLE D9000095460895 SH = SHIELD
A = ADDED WIRE W.F. = WIRE FERRULE
D = DELETED WIRE
CONF 003
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 86VU 1WW2-AE SH E0718-02-30 3152G7209 2M TK26 2000 80 86VU 1862VT SH E0718-02-30 (a) A
2 86VU 1WW2-AE 7F E0170FA2200 3152-7209 B 2M TK26 2000 80 86VU 1862VT 54K EN3155-016M2222 (a) A
3 86VU 1WW2-AE 7E E0170FA2200 3152-7209 R 2M TK26 2000 80 86VU 1862VT 54C EN3155-016M2222 (a) A
4 86VU 3436G7168 W.F. E0160-1-0H 3436-0330 2M CF24 2500 100 86VU 3411G7418 W.F. E0160-1-0H (a) A
5 86VU 3411G7418 W.F. E0160-1-0H 3436-0330 2M CF24 2500 100 86VU 3152G7208 W.F. E0160-1-0H (a) A
6 86VU 3152G7208 W.F. E0160-1-0H 3436-0330 2M CF24 2500 100 86VU 3152G7209 W.F. E0160-1-0H (a) A
7 86VU 3152G7209 W.F. E0160-1-0H 3436-0330 2M CF24 2500 100 86VU 3452G7083 W.F. E0160-1-0H (a) A
8 86VU 3452G7083 W.F. E0160-1-0H 3436-0330 2M CF24 2500 100 86VU 3436G7168 W.F. E0160-1-0H (a) A
9 86VU 1862VT SH E0718-02-30 3411G7418 2M TK26 2500 100 128 154VC SH E0718-02-30 (a) A
10 86VU 1862VT 54M EN3155-016M2222 3411-7418 B 2M TK26 2500 100 128 154VC 33 EN3155-008M2222 (a) A
11 86VU 1862VT 54E EN3155-016M2222 3411-7418 R 2M TK26 2500 100 128 154VC 32 EN3155-008M2222 (a) A
12 86VU 1862VT SH E0718-02-30 3436G7168 2M TK26 3500 140 128 106VC SH E0718-02-30 (a) A
13 86VU 1862VT 54J EN3155-016M2222 3436-7168 B 2M TK26 3500 140 128 106VC 33 EN3155-008M2222 (a) A
14 86VU 1862VT 54B EN3155-016M2222 3436-7168 R 2M TK26 3500 140 128 106VC 32 EN3155-008M2222 (a) A
15 86VU 1862VT SH E0718-02-30 3452G7083 2M TK26 3500 140 82VU 1SH2-AA SH E0718-02-30 (a) A
16 82VU 1SH2-AA W.S. NSA936604CA0931 3452-7083 B 2M TK26 3500 140 86VU 1862VT W.S. NSA936604CA0931 (a) A
17 86VU 1862VT W.S. NSA936604CA0931 3452-7083 R 2M TK26 3500 140 82VU 1SH2-AA W.S. NSA936604CA0931 (a) A
18 128 3411G7418 W.F. E0160-1-0H 3411-1628 2M CF24 500 20 128 154VC 34 EN3155-008M2222 (a) A
19 128 3436G7168 W.F. E0160-1-0H 3436-0329 2M CF24 500 20 128 106VC 34 EN3155-008M2222 (a) A
20
21
22
23
24
25
(a) = BUNDLE D9000095460895 W.F. = WIRE FERRULE
A = ADDED WIRE W.S. = WIRE STOWED
SH = SHIELD
CONF 003
BEFORE
0303
F.R. 39
67 R H
F.R. 3411-7417
68 B
F.R.
A 153VC
127 AB
C R 7E
3152-7203
B 7F
F.R.
- F.R. 1WW1 FWC-1
85VU
127
F
- F.R.
1853VT
127
85VU
AFTER
0303
39 AA
T R 6H
3452-7093
B 6J
1SH1 XPDR
ATC-1
81VU
H 127
AB
C R 7E
3152-7203
- F.R. B 7F
F.R.
1WW1 FWC-1
F.R. 85VU
127
67 R U
F.R. 3411-7417
68 B G
F.R.
A 153VC F
127
- F.R.
1853VT
127
85VU
CONF 003
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 85VU 3152G7203 W.F. 3436-0303 1M CF24 85VU 3411G7417 W.F. D
2 81VU 1SH1-AA SH E0718-02-30 3452G7093 1M TK26 3500 140 85VU 1853VT SH E0718-02-30 (d) A
3 85VU 1853VT W.S. NSA936604CA0931 3452-7093 B 1M TK26 3500 140 81VU 1SH1-AA W.S. NSA936604CA0931 (d) A
4 81VU 1SH1-AA W.S. NSA936604CA0931 3452-7093 R 1M TK26 3500 140 85VU 1853VT W.S. NSA936604CA0931 (d) A
5 85VU 3152G7203 W.F. E0160-1-0H 3436-0303 1M CF24 1000 40 85VU 3452G7093 W.F. E0160-1-0H (d) A
6 85VU 3452G7093 W.F. E0160-1-0H 3436-0303 1M CF24 1000 40 127 3411G7417 W.F. E0160-1-0H (d) A
7
8
9
10 85VU 1853VT SH E0718-02-30 3152G7203 1M TK26 85VU 1WW1-AB SH E0718-02-30 F.R.
11 85VU 1853VT 39F 3152-7203 B 1M TK26 85VU 1WW1-AB 7F F.R.
12 85VU 1853VT 39C 3152-7203 R 1M TK26 85VU 1WW1-AB 7E F.R.
13 127 153VC SH E0718-02-30 3411G7417 1M TK26 85VU 1853VT SH E0718-02-30 F.R.
14 127 153VC 68 3411-7417 B 1M TK26 85VU 1853VT 39G F.R.
15 127 153VC 67 3411-7417 R 1M TK26 85VU 1853VT 39H F.R.
16
17
18
19
20
21
22
23
24
25
(d) = BUNDLE D9000095461295 F.R. = FOR REFERENCE W.S. = WIRE STOWED
A = ADDED WIRE SH = SHIELD
D = DELETED WIRE W.F. = WIRE FERRULE
CONF 003
BEFORE
41
AA F.R. V
2E B D
3161-7165 F.R. AB
2D R - F.R.
B 5B
42 3137-7066
1WT3 DMC-3 V R 5A
85VU
127 D
1TV DMU
- F.R. OR
10TV FDIMU
1851VT 87VU
127 85VU 127
0343 S
AFTER
F.R. AB
41
AA F.R. V R 5B
3137-7066
2E B D B 5A
3161-7165
2D R X
1TV DMU
Y OR
1WT3 DMC-3 10TV FDIMU
85VU - F.R. 87VU
127 127
42
V AA
D B 7B
3452-7091
X R 7A
Y AB
- F.R. B 3G
3452-7092
1851VT R 3F .
127 85VU
CONF 003
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 87VU 3137G7066 W.F. 2286S0343 1S CF24 85VU 3161G7165 W.F. D
2 85VU 3137G7066 W.F. E0160-1-0H 2286S0343 1S CF24 1500 60 81VU 3452G7091 W.F. E0160-1-0H (a) A (c) (1)
3 81VU 3452G7091 W.F. E0160-1-0H 2286S0343 1S CF24 1500 60 81VU 3452G7092 W.F. E0160-1-0H (a) A (c) (1)
4 81VU 3452G7092 W.F. E0160-1-0H 2286S0343 1S CF24 1500 60 85VU 3161G7165 W.F. E0160-1-0H (a) A (c) (1)
5 81VU 1SH1-AA SH E0718-02-30 3452G7091 1S TK26 4000 160 85VU 1851VT SH E0718-02-30 (a) A (c) (1)
6 81VU 1SH1-AA 7B E0170FA2200 3452-7091 B 1S TK26 4000 160 85VU 1851VT 41X EN3155-016M2222 (a) A (c) (1)
7 81VU 1SH1-AA 7A E0170FA2200 3452-7091 R 1S TK26 4000 160 85VU 1851VT 42X EN3155-016M2222 (a) A (c) (1)
8 81VU 1SH1-AB SH E0718-02-30 3452G7092 1S TK26 4000 160 85VU 1851VT SH E0718-02-30 (a) A (c) (1)
9 81VU 1SH1-AB 3G E0170FA2200 3452-7092 B 1S TK26 4000 160 85VU 1851VT 41Y EN3155-016M2222 (a) A (c) (1)
10 81VU 1SH1-AB 3F E0170FA2200 3452-7092 R 1S TK26 4000 160 85VU 1851VT 42Y EN3155-016M2222 (a) A (c) (1)
11
12
13
14 87VU 1TV-AB SH E0718-02-30 3137G7066 1S TK26 85VU 1851VT SH E0718-02-30 F.R.
15 87VU 1TV-AB 5B 3137-7066 B 1S TK26 85VU 1851VT 41V F.R.
16 85VU 1851VT 42V 3137-7066 R 1S TK26 87VU 1TV-AB 5A F.R.
17 85VU 1WT3-AA SH E0718-02-30 3161G7165 1S TK26 85VU 1851VT SH E0718-02-30 F.R.
18 85VU 1WT3-AA 2E 3161-7165 B 1S TK26 85VU 1851VT 41D F.R.
19 85VU 1WT3-AA 2D 3161-7165 R 1S TK26 85VU 1851VT 42D F.R.
20
21
22
23
24
25
(a) = BUNDLE D9000095460895 F.R. = FOR REFERENCE S = SAFETY WIRE
A = ADDED WIRE SH = SHIELD (1) = (a) = D9000095460895 OR
D = DELETED WIRE W.F. = WIRE FERRULE (c) = D9000095461195
CONF 003
BEFORE
76 72
1630
1626
F.R. F.R.
77 7416 R 70
TK26
78 B 71
A 11VC 153VC A
127 127
37 37
1631
1629
F.R. F.R.
2M
35 R 35
7419
TK26 B
36 36
A 106VC 154VC A
128 128
CONF 003
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 127 11VC SH 3411G7416 1M TK26 127 153VC SH D
2 127 11VC 78 3411-7416 B 1M TK26 127 153VC 71 D
3 127 11VC 77 3411-7416 R 1M TK26 127 153VC 70 D
4 128 106VC SH 3411G7419 2M TK26 128 154VC SH D
5 128 106VC 36 3411-7419 B 2M TK26 128 154VC 36 D
6 128 106VC 35 3411-7419 R 2M TK26 128 154VC 35 D
7 127 3411G7416 W.F. 3411-1626 1M CF24 127 153VC 72 D
8 128 3411G7419 W.F. 3411-1629 2M CF24 128 154VC 37 D
9 127 3411G7416 W.F. 3411-1630 1M CF24 127 11VC 76 D
10 128 3411G7419 W.F. 3411-1631 2M CF24 128 106VC 37 D
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
D = DELETED WIRE
SH = SHIELD
W.F. = WIRE FERRULE
CONF 003
AFTER
4621-0210
30 AA
S R 2C
3452-7096
B 2D
T
AA 1SH2
F.R. -
2J R R XPDR
ATC-2
4621-7121 31 82VU
2K B R 128
1TX1 ATSU-1 B1 AA
4621-0211 S
81VU R 2C
127 - 3452-7097
739VG T B 2D
1 127 F.R. -
81VU 1813VT
127
81VU 1SH1
XPDR
ATC-1
81VU
127
CONF 003
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 81VU 1813VT SH E0718-02-30 3452G7097 1S TK26 1500 60 81VU 1SH1-AA SH E0718-02-30 (d) A
2 81VU 1813VT 31T EN3155-016M2222 3452-7097 B 1S TK26 1500 60 81VU 1SH1-AA 2D E0170FA2200 (d) A
3 81VU 1813VT 30T EN3155-016M2222 3452-7097 R 1S TK26 1500 60 81VU 1SH1-AA 2C E0170FA2200 (d) A
4 81VU 1813VT SH E0718-02-30 4621G7121 1S TK26 1000 40 81VU 1TX1-AA SH E0718-02-30 (d) A
5 81VU 1813VT 31R EN3155-016M2222 4621-7121 B 1S TK26 1000 40 81VU 1TX1-AA 2K E0170FA2200 (d) A
6 81VU 1813VT 30R EN3155-016M2222 4621-7121 R 1S TK26 1000 40 81VU 1TX1-AA 2J E0170FA2200 (d) A
7 81VU 4621G7121 W.F. E0160-1-0H 4621-0210 1S CF24 1000 40 81VU 3452G7096 W.F. E0160-1-0H (d) A
8 81VU 3452G7096 W.F. E0160-1-0H 4621-0210 1S CF24 1000 40 81VU 3452G7097 W.F. E0160-1-0H (d) A
9 81VU 4621G7121 W.F. E0160-1-0H 4621-0211 1S CF24 1500 60 81VU 739VG GND EN3155-015F2018 (d) A
10 81VU 1813VT SH E0718-02-30 3452G7096 1S TK26 3000 120 82VU 1SH2-AA SH E0718-02-30 (d) A
11 81VU 1813VT 31S EN3155-016M2222 3452-7096 B 1S TK26 3000 120 82VU 1SH2-AA 2D E0170FA2200 (d) A
12 81VU 1813VT 30S EN3155-016M2222 3452-7096 R 1S TK26 3000 120 82VU 1SH2-AA 2C E0170FA2200 (d) A
13
14
15
16
17
18
19
20
21
22
23
24
25
(d) = BUNDLE D9000095461295 W.F. = WIRE FERRULE
A = ADDED WIRE GND = GROUND
SH = SHIELD
CONF 003
AFTER
31
77 R A
7226 AA
F.R. 78 B
B R 6D
76 0437 3452-7094
- B 6E
A 11VC C F.R. -
127
H 1SH1
XPDR
ATC-1
J 81VU
70 R 127
3411-7416 -
71 B K
1813VT
3411-1626
127
F.R. 81VU
0438
72
A 153VC
127
CONF 003
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 81VU 1SH1-AA SH E0718-02-30 3452G7094 1M TK26 1500 60 81VU 1813VT SH E0718-02-30 (a) A
2 81VU 1SH1-AA W.S. NSA936604CA0931 3452-7094 B 1M TK26 1500 60 81VU 1813VT W.S. NSA936604CA0931 (a) A
3 81VU 1SH1-AA W.S. NSA936604CA0931 3452-7094 R 1M TK26 1500 60 81VU 1813VT W.S. NSA936604CA0931 (a) A
4 81VU 3436G7226 W.F. E0160-1-0H 3436-0438 1M CF24 1000 40 81VU 3452G7094 W.F. E0160-1-0H (a) A
5 81VU 3452G7094 W.F. E0160-1-0H 3436-0438 1M CF24 1000 40 81VU 3411G7416 W.F. E0160-1-0H (a) A
6 81VU 1813VT SH E0718-02-30 3411G7416 1M TK26 3500 140 127 153VC SH E0718-02-30 (a) A
7 81VU 1813VT 31K EN3155-016M2222 3411-7416 B 1M TK26 3500 140 127 153VC 71 EN3155-008M2222 (a) A
8 81VU 1813VT 31C EN3155-016M2222 3411-7416 R 1M TK26 3500 140 127 153VC 70 EN3155-008M2222 (a) A
9 81VU 1813VT SH E0718-02-30 3436G7226 1M TK26 2000 80 127 11VC SH E0718-02-30 (a) A
10 81VU 1813VT 31H EN3155-016M2222 3436-7226 B 1M TK26 2000 80 127 11VC 78 EN3155-008M2222 (a) A
11 81VU 1813VT 31A EN3155-016M2222 3436-7226 R 1M TK26 2000 80 127 11VC 77 EN3155-008M2222 (a) A
12 127 3411G7416 W.F. E0160-1-0H 3411-1626 1M CF24 500 20 127 153VC 72 EN3155-008M2222 (a) A
13 127 3436G7226 W.F. E0160-1-0H 3436-0437 1M CF24 500 20 127 11VC 76 EN3155-008M2222 (a) A
14
15
16
17
18
19
20
21
22
23
24
25
(a) = BUNDLE D9000095460895 W.F. = WIRE FERRULE
A = ADDED WIRE W.S. = WIRE STOWED
SH = SHIELD
CONF 003
AFTER
37
3411-1629
0427
F.R.
39
35 R B
3411-7419
36 B
A 154VC
128 AA
A R 6D
3452-7084
B 6E
-
1SH2 XPDR
35 R C ATC-2
7223 82VU
36 B 128
0428
F.R.
37
A 106VC -
128
K
1822VT
128
82VU
CONF 003
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 82VU 1SH2-AA SH E0718-02-30 3452G7084 2M TK26 1000 40 82VU 1822VT SH E0718-02-30 (a) A
2 82VU 1822VT W.S. NSA936604CA0931 3452-7084 B 2M TK26 1000 40 82VU 1SH2-AA W.S. NSA936604CA0931 (a) A
3 82VU 1SH2-AA W.S. NSA936604CA0931 3452-7084 R 2M TK26 1000 40 82VU 1822VT W.S. NSA936604CA0931 (a) A
4 82VU 3436G7223 W.F. E0160-1-0H 3436-0427 2M CF24 1000 40 82VU 3452G7084 W.F. E0160-1-0H (a) A
5 82VU 3452G7084 W.F. E0160-1-0H 3436-0427 2M CF24 1000 40 82VU 3411G7419 W.F. E0160-1-0H (a) A
6 82VU 1822VT SH E0718-02-30 3411G7419 2M TK26 3500 140 128 154VC SH E0718-02-30 (a) A
7 82VU 1822VT 39J EN3155-016M2222 3411-7419 B 2M TK26 3500 140 128 154VC 36 EN3155-008M2222 (a) A
8 82VU 1822VT 39B EN3155-016M2222 3411-7419 R 2M TK26 3500 140 128 154VC 35 EN3155-008M2222 (a) A
9 82VU 1822VT SH E0718-02-30 3436G7223 2M TK26 3000 120 128 106VC SH E0718-02-30 (a) A
10 82VU 1822VT 39K EN3155-016M2222 3436-7223 B 2M TK26 3000 120 128 106VC 36 EN3155-008M2222 (a) A
11 82VU 1822VT 39C EN3155-016M2222 3436-7223 R 2M TK26 3000 120 128 106VC 35 EN3155-008M2222 (a) A
12 128 3411G7419 W.F. E0160-1-0H 3411-1629 2M CF24 500 20 128 154VC 37 EN3155-008M2222 (a) A
13 128 3436G7223 W.F. E0160-1-0H 3436-0428 2M CF24 500 20 128 106VC 37 EN3155-008M2222 (a) A
14
15
16
17
18
19
20
21
22
23
24
25
(a) = BUNDLE D9000095460895 W.F. = WIRE FERRULE
A = ADDED WIRE W.S. = WIRE STOWED
SH = SHIELD
CONF 004
(1) Task A320-A-34-XX-1620-01004-920A-A - Modify the Equipment and the
Wiring in the Aft Electronics Rack 80VU
Job Set-Up Information
Working Area
Man-hours 47.00 h
Minimum Number of person 1
Elapsed Time 47.00 h
Material necessary to do the job
Part kit 341620A02R00
ITEM PART No. QTY (UM) KEYWORD DRAWING SEE NOTES
D9000095460895 1 BUNDLE
NSA935401-05 220 TIE
NSA935401-08 220 TIE
NSA935401-13 220 TIE
Manuals/Drawings References/Sheets
Task 22-66-34-000-002
AMM
Task 22-66-34-400-002
REV 00 Dec 21/15 A320-34-1620
REV 06 Jul 22/19 Page 143
A318/A319/A320/A321
SERVICE BULLETIN
Manuals/Drawings References/Sheets
Task 22-83-34-000-001
Task 22-83-34-400-001
Task 27-93-34-000-001
Task 27-93-34-400-001
Task 27-94-34-000-001
Task 27-94-34-400-001
Task 31-36-34-000-001
Task 31-36-34-000-002
Task 31-36-34-400-001
Task 31-36-34-400-002
Task 31-53-34-000-001
Task 31-53-34-400-001
Task 31-63-34-000-001
Task 31-63-34-400-001
Task 34-43-34-000-001
Task 34-43-34-400-001
Task 34-48-34-000-001
Task 34-48-34-400-001
Task 34-52-33-000-001
Task 34-52-33-400-001
20-33-00
20-33-44
ESPM
20-52-21
20-56-51
Procedure
(a) Standard Practices:
1 For the general installation of electrical wire harnesses, refer to Ref. ESPM
20-33-00.
2 For the cable tie application and tooling, refer to Ref. ESPM 20-33-44 and
Ref. ESPM 20-56-51.
3 Tag all the parts you must remove and retain to make the subsequent
installation easier.
4 Put all the retained hardware in identified plastic bags and attach the bags
to the related unit.
5 To install new wires, cut them to the necessary length, attach the terminals
and connect them.
(b) Remove and retain the FMGCs ( FIN 1CA1 and FIN 1CA2), refer to Ref. AMM Task
22-83-34-000-001.
(c) Remove and retain the FACs ( FIN 1CC1 and FIN 1CC2), refer to Ref. AMM Task
22-66-34-000-002.
(d) Remove and retain the SECs ( FIN 1CE1 and FIN 1CE2), refer to Ref. AMM Task
27-94-34-000-001.
(e) Remove and retain the ELACs ( FIN 2CE1 and FIN 2CE2), refer to Ref. AMM Task
27-93-34-000-001.
(f) Remove and retain the FWC ( FIN 1WW2), refer to Ref. AMM Task
31-53-34-000-001.
(g) Remove and retain the DMCs ( FIN 1WT2 and FIN 1WT3), refer to Ref. AMM Task
31-63-34-000-001.
(h) Remove and retain the ATC/Mode S Transponders ( FIN 1SH1 and FIN 1SH2), refer
to Ref. AMM Task 34-52-33-000-001.
(i) Remove and retain the TCAS ( FIN 1SG), refer to Ref. AMM Task
34-43-34-000-001.
(j) If installed, remove and retain the DMU ( FIN 1TV), refer to Ref. AMM Task
31-36-34-000-001.
(k) If installed, remove and retain the FDIMU ( FIN 10TV), refer to Ref. AMM Task
31-36-34-000-002.
(l) Remove and retain the GPWC ( FIN 1WZ), refer to Ref. AMM Task
34-48-34-000-001.
(m) Modify the equipment in the aft electronics rack Electrical Panel 80VU
Refer to Ref. Fig. Location of the Terminal Blocks in the Aft Electronics Rack 80VU
1 Modify the terminal block FIN 1813VT in the shelf Electrical Panel 81VU
a Loosen the end clamps at each end of the terminal block.
b Install at position 31:
FIN 1813VT31
1 MODULE NSA937901MA2206
FIN 1822VT39
1 MODULE NSA937901MA2206
FIN 1831VT10
1 MODULE NSA937901MA2205
FIN 1840VT12
1 MODULE NSA937901MA2205
FIN 1860VT29
1 MODULE NSA937901MA2205 Discard
c Install at position 29:
1 MODULE-FALSE NSA937901FM
d If necessary install at position 35:
1 MODULE-FALSE NSA937901FM
e Install at position 36:
FIN 1860VT36
1 MODULE NSA937901MA2205
FIN 1860VT37
1 MODULE NSA937901MA2205
FIN 1862VT54
1 MODULE NSA937901MA2206
1 BUNDLE D9000095460895
3 Attach the wires with:
Refer to Ref. ESPM 20-33-44 and Ref. ESPM 20-56-51
1 BUNDLE D9000095461295
5 Attach the wires with:
Refer to Ref. ESPM 20-33-44 and Ref. ESPM 20-56-51
50 TIE-CABLE NSA935401-05
50 TIE-CABLE NSA935401-08
50 TIE-CABLE NSA935401-13
6 Do a continuity test of the new and/or modified electrical wires, refer to
Ref. ESPM 20-52-21.
(o) Install the GPWC ( FIN 1WZ) retained at removal, refer to Ref. AMM Task
34-48-34-400-001.
(p) If removed, install the FDIMU ( FIN 10TV) retained at removal, refer to Ref. AMM
Task 31-36-34-400-002.
(q) If removed, install the DMU ( FIN 1TV) retained at removal, refer to Ref. AMM
Task 31-36-34-400-001.
(r) Install the TCAS ( FIN 1SG) retained at removal, refer to Ref. AMM Task
34-43-34-400-001.
(s) Install the ATC/Mode S Transponders ( FIN 1SH1 and FIN 1SH2) retained at
removal, refer to Ref. AMM Task 34-52-33-400-001.
(t) Install the DMCs ( FIN 1WT2 and FIN 1WT3) retained at removal, refer to Ref.
AMM Task 31-63-34-400-001.
(u) Install the FWC ( FIN 1WW2) retained at removal, refer to Ref. AMM Task
31-53-34-400-001.
(v) Install the ELACs ( FIN 2CE1 and FIN 2CE2) retained at removal, refer to Ref. AMM
Task 27-93-34-400-001.
(w) Install the SECs ( FIN 1CE1 and FIN 1CE2) retained at removal, refer to Ref. AMM
Task 27-94-34-400-001.
(x) Install the FACs ( FIN 1CC1 and FIN 1CC2) retained at removal, refer to Ref. AMM
Task 22-66-34-400-002.
(y) Install the FMGCs ( FIN 1CA1 and FIN 1CA2) retained at removal, refer to Ref.
AMM Task 22-83-34-400-001.
CONF 004
824
A
FR24
Z120
FR1
1822VT
1813VT
1840VT
1860VT
1862VT
1831VT 1853VT
A
80VU
ICN-A320-A-34XX1620-A-FAPE3-00MEY-A-002-01
CONF 004
0338 S 17
BEFORE
3457-0071
8
AE
F.R.
7B B U
3443-7065 V
7A R
P B 16
X 3457-7077
1SG R 13
CMPTR D
TCAS Y 83VC A
82VU 127
128 E
AB
F AB
4K B
2286-7103 B 4K
4J R G 2269-7071
R 4J
1CA1 L
FMGC-1 1CC1
83VU FAC-1
127 M 83VU
127
N
AD
AA
4G B S
2792-7122 B S 9K
4F R S 2792-7152
T R S 9J
50 A
AA AD
P
2B B S B S 9B
M 2792-7123 B 2792-7150
2A R S R S 9A
F
F.R. - F.R. S
B 43 2CE1 7S 7S 1CE1
3436-7182 F.R. ELAC-1 SEC-1
S R 42 83VU H 83VU
127 127
F.R. 79VC A
127 C
J
F.R.
14 B S J
F.R. 7079
13 R S H B S
R
A 151VC 7230
127 F.R. -
A R S K
1851VT 1831VT
127 127
85VU 83VU
0825 S
DELETED WIRE F.R. FOR REFERENCE EXISTING WIRE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 3411
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK26 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 1S
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-34XX1620-A-FAPE3-00MG1-A-002-01
CONF 004
0338 S
AFTER
8 AA
X B 2B
AE 3452-7095
R 2A
7B B U
3443-7065 V
7A R 1SH1
P XPDR
Y ATC-1
1SG 81VU
CMPTR D 127
TCAS
82VU
128 E B 16
3457-7077
AB R 13
F
4K B
3457-0071
2286-7103
4J R G F.R.
1CA1 L
FMGC-1
83VU
127 M 17
83VC A
N 127
AD 10
AB
4G B S X
2792-7122 B 4K
4F R S V 2269-7071
U R 4J
50 D 1CC1
AA FAC-1
P
2B B S Y 83VU
M 2792-7123 E 127
2A R S
F
F.R. - F.R. P
B 43 2CE1 7S AA
3436-7182 F.R. ELAC-1
S R 42 83VU G B S 9K
127 2792-7152
F.R. 79VC A R S 9J
127 F
J
F.R. AD
14 B S L
F.R. 7079 B S 9B
13 R S H B S 2792-7150
N R S 9A
A 151VC 7230
127 F.R. -
A R S M 1CE1
7S SEC-1
1851VT 1831VT 83VU
127 127 127
85VU 83VU
0825 S
NEW WIRE F.R. FOR REFERENCE EXISTING WIRE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 3411
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK26 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 1S
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-34XX1620-A-FAPE3-00MG2-A-002-01
CONF 004
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 83VU 1831VT SH 2269G7071 1S TK26 83VU 1CC1-AB SH D
2 83VU 1831VT 8E 2269-7071 B 1S TK26 83VU 1CC1-AB 4K D
3 83VU 1CC1-AB 4J 2269-7071 R 1S TK26 83VU 1831VT 8B D
4 83VU 1831VT SH 2286G7103 1S TK26 83VU 1CA1-AB SH D
5 83VU 1831VT 8D 2286-7103 B 1S TK26 83VU 1CA1-AB 4K D
6 83VU 1CA1-AB 4J 2286-7103 R 1S TK26 83VU 1831VT 8A D
7 83VU 1831VT SH 2792G7122 7S TK26 83VU 2CE1-AD SH D
8 83VU 1831VT 8G 2792S7122 B 7S TK26 83VU 2CE1-AD 4G D
9 83VU 1831VT 8H 2792S7122 R 7S TK26 83VU 2CE1-AD 4F D
10 83VU 1831VT SH 2792G7123 7S TK26 83VU 2CE1-AA SH D
11 83VU 1831VT 8F 2792S7123 B 7S TK26 83VU 2CE1-AA 2B D
12 83VU 1831VT 8C 2792S7123 R 7S TK26 83VU 2CE1-AA 2A D
13 83VU 1831VT SH 2792G7150 7S TK26 83VU 1CE1-AD SH D
14 83VU 1831VT 8N 2792S7150 B 7S TK26 83VU 1CE1-AD 9B D
15 83VU 1831VT 8R 2792S7150 R 7S TK26 83VU 1CE1-AD 9A D
16 83VU 1831VT SH 2792G7152 7S TK26 83VU 1CE1-AA SH D
17 83VU 1831VT 8L 2792S7152 B 7S TK26 83VU 1CE1-AA 9K D
18 83VU 1831VT 8J 2792S7152 R 7S TK26 83VU 1CE1-AA 9J D
19
20
21
22
23
24
25
D = DELETED WIRE
SH = SHIELD
S = SAFETY WIRE
CONF 004
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 83VU 2792G7152 W.F. 3411S0338 7S CF24 83VU 2269G7071 W.F. D
2 83VU 2269G7071 W.F. 3411S0338 7S CF24 83VU 3457G7077 W.F. D
3 83VU 3457G7077 W.F. 3411S0338 7S CF24 83VU 3443G7065 W.F. D
4 83VU 3443G7065 W.F. 3411S0338 7S CF24 83VU 2286G7103 W.F. D
5 83VU 2286G7103 W.F. 3411S0338 7S CF24 83VU 2792G7122 W.F. D
6 83VU 2792G7122 W.F. 3411S0338 7S CF24 83VU 2792G7123 W.F. D
7 83VU 2792G7123 W.F. 3411S0338 7S CF24 83VU 3411G7230 W.F. D
8 83VU 3411G7230 W.F. 3411S0338 7S CF24 83VU 2792G7150 W.F. D
9 83VU 2792G7150 W.F. 3411S0338 7S CF24 83VU 2792G7152 W.F. D
10 83VU 1831VT SH 3411G7230 1S TK26 85VU 1851VT SH D
11 83VU 1831VT 8M 3411S7230 B 1S TK26 85VU 1851VT 50F D
12 83VU 1831VT 8K 3411S7230 R 1S TK26 85VU 1851VT 50A D
13 83VU 1831VT SH 3443G7065 1S TK26 82VU 1SG-AE SH D
14 83VU 1831VT 8U 3443-7065 B 1S TK26 82VU 1SG-AE 7B D
15 83VU 1831VT 8T 3443-7065 R 1S TK26 82VU 1SG-AE 7A D
16 83VU 1831VT SH 3457G7077 1S TK26 127 83VC SH D
17 83VU 1831VT 8P 3457-7077 B 1S TK26 127 83VC 16 D
18 127 83VC 13 3457-7077 R 1S TK26 83VU 1831VT 8S D
19 127 3436G7182 W.F. 3411S0825 1S CF24 85VU 3411G7230 W.F. D
20 85VU 3411G7230 W.F. 3411S0825 1S CF24 127 3411G7079 W.F. D
21 127 3457G7077 W.F. 3457-0071 1S CF24 127 83VC 17 D
22
23
24
25
D = DELETED WIRE S = SAFETY WIRE
SH = SHIELD
W.F. = WIRE FERRULE
CONF 004
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 83VU 1831VT SH E0718-02-30 2269G7071 1S TK26 2000 80 83VU 1CC1-AB SH E0718-02-30 (a) A
2 83VU 1831VT 8E EN3155-016M2222 2269-7071 B 1S TK26 2000 80 83VU 1CC1-AB 4K E0170FA2200 (a) A
3 83VU 1CC1-AB 4J E0170FA2200 2269-7071 R 1S TK26 2000 80 83VU 1831VT 10E EN3155-016M2222 (a) A
4 83VU 1831VT SH E0718-02-30 2286G7103 1S TK26 1500 60 83VU 1CA1-AB SH E0718-02-30 (a) A
5 83VU 1831VT 8D EN3155-016M2222 2286-7103 B 1S TK26 1500 60 83VU 1CA1-AB 4K E0170FA2200 (a) A
6 83VU 1CA1-AB 4J E0170FA2200 2286-7103 R 1S TK26 1500 60 83VU 1831VT 10D EN3155-016M2222 (a) A
7 83VU 1831VT SH E0718-02-30 2792G7122 7S TK26 1500 60 83VU 2CE1-AD SH E0718-02-30 (a) A
8 83VU 1831VT 8G EN3155-016M2222 2792S7122 B 7S TK26 1500 60 83VU 2CE1-AD 4G E0170FA2200 (a) A
9 83VU 1831VT 10G EN3155-016M2222 2792S7122 R 7S TK26 1500 60 83VU 2CE1-AD 4F E0170FA2200 (a) A
10 83VU 1831VT SH E0718-02-30 2792G7123 7S TK26 1500 60 83VU 2CE1-AA SH E0718-02-30 (a) A
11 83VU 1831VT 8F EN3155-016M2222 2792S7123 B 7S TK26 1500 60 83VU 2CE1-AA 2B E0170FA2200 (a) A
12 83VU 1831VT 10F EN3155-016M2222 2792S7123 R 7S TK26 1500 60 83VU 2CE1-AA 2A E0170FA2200 (a) A
13 83VU 1831VT SH E0718-02-30 2792G7150 7S TK26 1000 40 83VU 1CE1-AD SH E0718-02-30 (a) A
14 83VU 1831VT 8N EN3155-016M2222 2792S7150 B 7S TK26 1000 40 83VU 1CE1-AD 9B E0170FA2200 (a) A
15 83VU 1831VT 10N EN3155-016M2222 2792S7150 R 7S TK26 1000 40 83VU 1CE1-AD 9A E0170FA2200 (a) A
16 83VU 1831VT SH E0718-02-30 2792G7152 7S TK26 1000 40 83VU 1CE1-AA SH E0718-02-30 (a) A
17 83VU 1831VT 8L EN3155-016M2222 2792S7152 B 7S TK26 1000 40 83VU 1CE1-AA 9K E0170FA2200 (a) A
18 83VU 1831VT 10L EN3155-016M2222 2792S7152 R 7S TK26 1000 40 83VU 1CE1-AA 9J E0170FA2200 (a) A
19
20
21
22
23
24
25
(a) = BUNDLE D9000095460895 S = SAFETY WIRE
A = ADDED WIRE
SH = SHIELD
CONF 004
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 83VU 2269G7071 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 3457G7077 W.F. E0160-1-0H (a) A
2 83VU 3457G7077 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 3452G7095 W.F. E0160-1-0H (a) A
3 83VU 3452G7095 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 3443G7065 W.F. E0160-1-0H (a) A
4 83VU 3443G7065 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 2286G7103 W.F. E0160-1-0H (a) A
5 83VU 2286G7103 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 2792G7122 W.F. E0160-1-0H (a) A
6 83VU 2792G7122 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 2792G7123 W.F. E0160-1-0H (a) A
7 83VU 2792G7123 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 3411G7230 W.F. E0160-1-0H (a) A
8 83VU 3411G7230 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 2792G7150 W.F. E0160-1-0H (a) A
9 83VU 2792G7150 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 2792G7152 W.F. E0160-1-0H (a) A
10 83VU 2792G7152 W.F. E0160-1-0H 3411S0338 1S CF24 5000 200 83VU 2269G7071 W.F. E0160-1-0H (a) A
11 83VU 1831VT SH E0718-02-30 3411G7230 1S TK26 3500 140 85VU 1851VT SH E0718-02-30 (a) A
12 83VU 1831VT 8M EN3155-016M2222 3411S7230 B 1S TK26 3500 140 85VU 1851VT 50F EN3155-016M2222 (a) A
13 83VU 1831VT 10M EN3155-016M2222 3411S7230 R 1S TK26 3500 140 85VU 1851VT 50A EN3155-016M2222 (a) A
14 83VU 1831VT SH E0718-02-30 3443G7065 1S TK26 4000 160 82VU 1SG-AE SH E0718-02-30 (a) A
15 83VU 1831VT 8U EN3155-016M2222 3443-7065 B 1S TK26 4000 160 82VU 1SG-AE 7B E0170FA2200 (a) A
16 83VU 1831VT 10U EN3155-016M2222 3443-7065 R 1S TK26 4000 160 82VU 1SG-AE 7A E0170FA2200 (a) A
17 83VU 1831VT SH E0718-02-30 3452G7095 1S TK26 3500 140 81VU 1SH1-AA SH E0718-02-30 (a) A
18 83VU 1831VT 8X EN3155-016M2222 3452-7095 B 1S TK26 3500 140 81VU 1SH1-AA 2B E0170FA2200 (a) A
19 81VU 1SH1-AA 2A E0170FA2200 3452-7095 R 1S TK26 3500 140 83VU 1831VT 10X EN3155-016M2222 (a) A
20 83VU 1831VT SH E0718-02-30 3457G7077 1S TK26 3500 140 127 83VC SH E0718-02-30 (a) A
21 83VU 1831VT 8P EN3155-016M2222 3457-7077 B 1S TK26 3500 140 127 83VC 16 EN3155-008M2222 (a) A
22 127 83VC 13 EN3155-008M2222 3457-7077 R 1S TK26 3500 140 83VU 1831VT 10P EN3155-016M2222 (a) A
23 127 3436G7182 W.F. E0160-1-0H 3411S0825 1S CF24 1000 40 85VU 3411G7230 W.F. E0160-1-0H (a) A
24 85VU 3411G7230 W.F. E0160-1-0H 3411S0825 1S CF24 1000 40 127 3411G7079 W.F. E0160-1-0H (a) A
25 127 3457G7077 W.F. E0160-1-0H 3457-0071 1S CF24 500 20 127 83VC 17 EN3155-008M2222 (a) A
(a) = BUNDLE D9000095460895 W.F. = WIRE FERRULE
A = ADDED WIRE S = SAFETY WIRE
SH = SHIELD
CONF 004
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 127 151VC SH E0718-02-30 3411G7079 1S TK26 85VU 1851VT SH E0718-02-30 F.R.
2 127 151VC 14 3411S7079 B 1S TK26 85VU 1851VT 50M F.R.
3 127 151VC 13 3411S7079 R 1S TK26 85VU 1851VT 50H F.R.
4 127 79VC SH E0718-02-30 3436G7182 1S TK26 85VU 1851VT SH E0718-02-30 F.R.
5 127 79VC 43 3436-7182 B 1S TK26 85VU 1851VT 50P F.R.
6 85VU 1851VT 50S 3436-7182 R 1S TK26 127 79VC 42 F.R.
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
F.R. = FOR REFERENCE
SH = SHIELD
S = SAFETY WIRE
CONF 004
BEFORE
0820 S
AB 10
4K B M
2269-7069 V
4J R
E
X
1CC2
FAC-2 F
84VU Y
128
AB
P
AD B 4K
2286-7107
5G B S G R 4J
2792-7116
5F R S
D 1CA2
FMGC-2
2CE2 8S 84VU
ELAC-2 N 128
84VU
128
U
44
L
3436-0337
8S
AD
B S 9B
2792-7142
F.R. B R S 9A
43 B AA
3436-7172 K
42 R B S 9K
2792-7144
A 36VC A R S 9J
128
C 1CE2
7 0443 S SEC-2
F.R. 6 B S 84VU
7142 T 128
5 R S
A 42VC H
128 S 36
0458
J
R 7090 B
F.R.
TK24 R F.R.
P R
B S 35
A 198VC 7091
188VU S R S 34
128
1840VT 152VC A
128 128
84VU
DELETED WIRE F.R. FOR REFERENCE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 3411
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK26 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 2S
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-34XX1620-A-FAPE3-00MG5-A-002-01
CONF 004
AFTER
0820 S
10 AA
X B 2B
AB V 3452-7090
R 2A
4K B M
2269-7069 Y
4J R 1SH2
E XPDR
ATC-2
1CC2 FAC-2 82VU
84VU 128 F 128
AD 8S AB
P
5G B S B 4K
2792-7116 2286-7107
5F R S G R 4J
3436-0337
U
L
F.R. 8S
12
AD
X
43 B B S 9B
3436-7172 2792-7142
42 R E R S 9A
A 36VC
128 AA
F
B S 9K
2792-7144
7 0443 S D R S 9J
6 B S V
F.R. 7142 M 1CE2
5 R S SEC-2
Y 84VU
A 42VC U 128
128
R B N
F.R. 7090
TK24 S 36
P R
0458
P
A 198VC
128 188VU
G
B S 35
7091
L R S 34
1840VT 152VC A
128 128
84VU
NEW WIRE F.R. FOR REFERENCE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 3411
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK26 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 2S
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-34XX1620-A-FAPE3-00MG6-A-002-01
CONF 004
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 84VU 1840VT SH 2269G7069 2S TK26 84VU 1CC2-AB SH D
2 84VU 1840VT 10M 2269-7069 B 2S TK26 84VU 1CC2-AB 4K D
3 84VU 1840VT 10C 2269-7069 R 2S TK26 84VU 1CC2-AB 4J D
4 84VU 1840VT SH 2286G7107 2S TK26 84VU 1CA2-AB SH D
5 84VU 1840VT 10F 2286-7107 B 2S TK26 84VU 1CA2-AB 4K D
6 84VU 1840VT 10K 2286-7107 R 2S TK26 84VU 1CA2-AB 4J D
7 84VU 1840VT SH 2792G7116 8S TK26 84VU 2CE2-AD SH D
8 84VU 1840VT 10P 2792S7116 B 8S TK26 84VU 2CE2-AD 5G D
9 84VU 1840VT 10J 2792S7116 R 8S TK26 84VU 2CE2-AD 5F D
10 84VU 1840VT SH 2792G7142 8S TK26 84VU 1CE2-AD SH D
11 84VU 1840VT 10E 2792S7142 B 8S TK26 84VU 1CE2-AD 9B D
12 84VU 1840VT 10B 2792S7142 R 8S TK26 84VU 1CE2-AD 9A D
13 84VU 1840VT SH 2792G7144 8S TK26 84VU 1CE2-AA SH D
14 84VU 1840VT 10D 2792S7144 B 8S TK26 84VU 1CE2-AA 9K D
15 84VU 1840VT 10A 2792S7144 R 8S TK26 84VU 1CE2-AA 9J D
16 84VU 3411G7142 W.F. 3411S0820 2S CF24 188VU 3411G7090 W.F. D
17 188VU 3411G7090 W.F. 3411S0820 2S CF24 128 3411G7091 W.F. D
18 128 3411G7091 W.F. 3411S0820 2S CF24 84VU 2792G7144 W.F. D
19 84VU 2792G7144 W.F. 3411S0820 2S CF24 84VU 2792G7142 W.F. D
20 84VU 2792G7142 W.F. 3411S0820 2S CF24 84VU 2286G7107 W.F. D
21 84VU 2286G7107 W.F. 3411S0820 2S CF24 84VU 2269G7069 W.F. D
22 84VU 2269G7069 W.F. 3411S0820 2S CF24 84VU 2792G7116 W.F. D
23 84VU 2792G7116 W.F. 3411S0820 2S CF24 84VU 3436G7172 W.F. D
24 84VU 3436G7172 W.F. 3411S0820 2S CF24 84VU 3411G7142 W.F. D
25
D = DELETED WIRE S = SAFETY WIRE
SH = SHIELD
W.F. = WIRE FERRULE
CONF 004
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 84VU 1840VT SH 3411G7090 2S TK24 188VU 198VC SH D
2 84VU 1840VT 10G 3411-7090 B 2S TK24 188VU 198VC R D
3 84VU 1840VT 10R 3411-7090 R 2S TK24 188VU 198VC P D
4 84VU 1840VT SH 3411G7091 2S TK26 128 152VC SH D
5 84VU 1840VT 10L 3411S7091 B 2S TK26 128 152VC 35 D
6 84VU 1840VT 10S 3411S7091 R 2S TK26 128 152VC 34 D
7 84VU 1840VT SH 3411G7142 2S TK26 128 42VC SH D
8 84VU 1840VT 10N 3411S7142 B 2S TK26 128 42VC 6 D
9 84VU 1840VT 10H 3411S7142 R 2S TK26 128 42VC 5 D
10 84VU 1840VT SH 3436G7172 2S TK26 128 36VC SH D
11 84VU 1840VT 10U 3436-7172 B 2S TK26 128 36VC 43 D
12 84VU 1840VT 10T 3436-7172 R 2S TK26 128 36VC 42 D
13 84VU 3411G7091 W.F. 3411S0458 2S CF24 128 152VC 36 D
14 128 3411G7142 W.F. 3411S0443 2S CF24 128 42VC 7 D
15 128 3436G7172 W.F. 3436-0337 2S CF24 128 36VC 44 D
16
17
18
19
20
21
22
23
24
25
D = DELETED WIRE S = SAFETY WIRE
SH = SHIELD
W.F. = WIRE FERRULE
CONF 004
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 84VU 1840VT SH E0718-02-30 2269G7069 2S TK26 1000 40 84VU 1CC2-AB SH E0718-02-30 (a) A
2 84VU 1840VT 10M EN3155-016M2222 2269-7069 B 2S TK26 1000 40 84VU 1CC2-AB 4K E0170FA2200 (a) A
3 84VU 1840VT 12M EN3155-016M2222 2269-7069 R 2S TK26 1000 40 84VU 1CC2-AB 4J E0170FA2200 (a) A
4 84VU 1840VT SH E0718-02-30 2286G7107 2S TK26 1500 60 84VU 1CA2-AB SH E0718-02-30 (a) A
5 84VU 1840VT 10F EN3155-016M2222 2286-7107 B 2S TK26 1500 60 84VU 1CA2-AB 4K E0170FA2200 (a) A
6 84VU 1840VT 12F EN3155-016M2222 2286-7107 R 2S TK26 1500 60 84VU 1CA2-AB 4J E0170FA2200 (a) A
7 84VU 1840VT SH E0718-02-30 2792G7116 8S TK26 2500 100 84VU 2CE2-AD SH E0718-02-30 (a) A
8 84VU 1840VT 10P EN3155-016M2222 2792S7116 B 8S TK26 2500 100 84VU 2CE2-AD 5G E0170FA2200 (a) A
9 84VU 1840VT 12P EN3155-016M2222 2792S7116 R 8S TK26 2500 100 84VU 2CE2-AD 5F E0170FA2200 (a) A
10 84VU 1840VT SH E0718-02-30 2792G7142 8S TK26 2000 80 84VU 1CE2-AD SH E0718-02-30 (a) A
11 84VU 1840VT 10E EN3155-016M2222 2792S7142 B 8S TK26 2000 80 84VU 1CE2-AD 9B E0170FA2200 (a) A
12 84VU 1840VT 12E EN3155-016M2222 2792S7142 R 8S TK26 2000 80 84VU 1CE2-AD 9A E0170FA2200 (a) A
13 84VU 1840VT SH E0718-02-30 2792G7144 8S TK26 2000 80 84VU 1CE2-AA SH E0718-02-30 (a) A
14 84VU 1840VT 10D EN3155-016M2222 2792S7144 B 8S TK26 2000 80 84VU 1CE2-AA 9K E0170FA2200 (a) A
15 84VU 1840VT 12D EN3155-016M2222 2792S7144 R 8S TK26 2000 80 84VU 1CE2-AA 9J E0170FA2200 (a) A
16 84VU 3411G7142 W.F. E0160-1-0H 3411S0820 2S CF24 5000 200 84VU 3411G7090 W.F. E0160-1-0H (a) A
17 84VU 3411G7090 W.F. E0160-1-0H 3411S0820 2S CF24 5000 200 128 3411G7091 W.F. E0160-1-0H (a) A
18 128 3411G7091 W.F. E0160-1-0H 3411S0820 2S CF24 5000 200 84VU 2792G7144 W.F. E0160-1-0H (a) A
19 84VU 2792G7144 W.F. E0160-1-0H 3411S0820 2S CF24 5000 200 84VU 2792G7142 W.F. E0160-1-0H (a) A
20 84VU 2792G7142 W.F. E0160-1-0H 3411S0820 2S CF24 5000 200 84VU 2286G7107 W.F. E0160-1-0H (a) A
21 84VU 2286G7107 W.F. E0160-1-0H 3411S0820 2S CF24 5000 200 84VU 3452G7090 W.F. E0160-1-0H (a) A
22 84VU 3452G7090 W.F. E0160-1-0H 3411S0820 2S CF24 5000 200 84VU 2269G7069 W.F. E0160-1-0H (a) A
23 84VU 2269G7069 W.F. E0160-1-0H 3411S0820 2S CF24 5000 200 84VU 2792G7116 W.F. E0160-1-0H (a) A
24 84VU 2792G7116 W.F. E0160-1-0H 3411S0820 2S CF24 5000 200 84VU 3436G7172 W.F. E0160-1-0H (a) A
25 84VU 3436G7172 W.F. E0160-1-0H 3411S0820 2S CF24 5000 200 84VU 3411G7142 W.F. E0160-1-0H (a) A
(a) = BUNDLE D9000095460895 W.F. = WIRE FERRULE
A = ADDED WIRE S = SAFETY WIRE
SH = SHIELD
CONF 004
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 84VU 1840VT SH E0718-02-30 3411G7090 2S TK24 6000 240 188VU 198VC SH E0718-02-30 (a) A
2 84VU 1840VT 10G EN3155-016M2222 3411-7090 B 2S TK24 6000 240 188VU 198VC R EN3155-019F2018 (a) A
3 84VU 1840VT 12G EN3155-016M2222 3411-7090 R 2S TK24 6000 240 188VU 198VC P EN3155-019F2018 (a) A
4 84VU 1840VT SH E0718-02-30 3411G7091 2S TK26 4000 160 128 152VC SH E0718-02-30 (a) A
5 84VU 1840VT 10L EN3155-016M2222 3411S7091 B 2S TK26 4000 160 128 152VC 35 EN3155-008M2222 (a) A
6 84VU 1840VT 12L EN3155-016M2222 3411S7091 R 2S TK26 4000 160 128 152VC 34 EN3155-008M2222 (a) A
7 84VU 1840VT SH E0718-02-30 3411G7142 2S TK26 2000 80 128 42VC SH E0718-02-30 (a) A
8 84VU 1840VT 10N EN3155-016M2222 3411S7142 B 2S TK26 2000 80 128 42VC 6 EN3155-008M2222 (a) A
9 84VU 1840VT 12N EN3155-016M2222 3411S7142 R 2S TK26 2000 80 128 42VC 5 EN3155-008M2222 (a) A
10 84VU 1840VT SH E0718-02-30 3436G7172 2S TK26 2000 80 128 36VC SH E0718-02-30 (a) A
11 84VU 1840VT 10U EN3155-016M2222 3436-7172 B 2S TK26 2000 80 128 36VC 43 EN3155-008M2222 (a) A
12 84VU 1840VT 12U EN3155-016M2222 3436-7172 R 2S TK26 2000 80 128 36VC 42 EN3155-008M2222 (a) A
13 84VU 1840VT SH E0718-02-30 3452G7090 2S TK26 2500 100 82VU 1SH2-AA SH E0718-02-30 (a) A
14 84VU 1840VT 10X EN3155-016M2222 3452-7090 B 2S TK26 2500 100 82VU 1SH2-AA 2B E0170FA2200 (a) A
15 82VU 1SH2-AA 2A E0170FA2200 3452-7090 R 2S TK26 2500 100 84VU 1840VT 12X EN3155-016M2222 (a) A
16 84VU 3411G7091 W.F. E0160-1-0H 3411S0458 2S CF24 500 20 128 152VC 36 EN3155-008M2222 (a) A
17 128 3411G7142 W.F. E0160-1-0H 3411S0443 2S CF24 500 20 128 42VC 7 EN3155-008M2222 (a) A
18 128 3436G7172 W.F. E0160-1-0H 3436-0337 2S CF24 500 20 128 36VC 44 EN3155-008M2222 (a) A
19
20
21
22
23
24
25
(a) = BUNDLE D9000095460895 W.F. = WIRE FERRULE
A = ADDED WIRE S = SAFETY WIRE
SH = SHIELD
CONF 004
BEFORE
29
AE
8A R B
3152-7145
8B B
S
1WW2 FWC-2
86VU
128 A
AA
K R 2F
3161-7167
B 2G
R
1WT3
C DMC-3
85VU
127
T
AA
J R 2F
13 3161-7170
B 2G
3411-0301
V
1WT2
E DMC-2
F.R. 86VU
128
P
M
14 R
3411-7171
20 B Y
L AA
A 152VC
128 R 9C
3448-7068
X B 9D
15 R
7194
16 B G 1WZ
GPWC
17 0349 88VU
D 128
F.R. AB
U
R 5J
13 0450 7195
F B 5K
11 R
7233
12 B N 1CA2
FMGC-2
A 36VC 1860VT 84VU
128 128 128
86VU
0354
DELETED WIRE F.R. FOR REFERENCE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 2286
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK26 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 2S
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-34XX1620-A-FAPE3-00MG9-A-002-01
CONF 004
AFTER
36 AB
D R 3F
AE 3452-7081
B 3G
8A R P
3152-7145 AA
8B B
E R 7A
3452-7082
1WW2 FWC-2 B 7B
86VU V
128
X 1SH2
XPDR
ATC-2
L 82VU 128
AA
F R 2F
Y 3161-7167
B 2G
N
1WT3
M DMC-3
85VU
127
U
AA
G R 2F
13 3161-7170
37 B 2G
D
3411-0301
1WT2
E DMC-2
F.R. 86VU
128
P
14 R
3411-7171 F
20 B
A 152VC AA
G
128 R 9C
3448-7068
U B 9D
15 R
7194 Y
16 B L 1WZ
GPWC
17 0349 88VU
X 128
AB
F.R. V
R 5J
13 0450 7195
M B 5K
11 R
7233
12 B N 1CA2
FMGC-2
A 36VC 1860VT 84VU
128 128 86VU 128
0354
NEW WIRE F.R. FOR REFERENCE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 2286
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK26 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 2S
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-34XX1620-A-FAPE3-00MGA-A-002-01
CONF 004
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 86VU 1860VT SH 3152G7145 2S TK26 86VU 1WW2-AE SH D
2 86VU 1860VT 29E 3152-7145 B 2S TK26 86VU 1WW2-AE 8B D
3 86VU 1860VT 29B 3152-7145 R 2S TK26 86VU 1WW2-AE 8A D
4 86VU 1860VT SH 3161G7170 2S TK26 86VU 1WT2-AA SH D
5 86VU 1860VT 29L 3161-7170 B 2S TK26 86VU 1WT2-AA 2G D
6 86VU 1860VT 29J 3161-7170 R 2S TK26 86VU 1WT2-AA 2F D
7 86VU 3152G7145 W.F. 2286-0354 2S CF24 86VU 3411G7171 W.F. D
8 86VU 3411G7171 W.F. 2286-0354 2S CF24 128 2286G7194 W.F. D
9 128 2286G7194 W.F. 2286-0354 2S CF24 128 2286G7233 W.F. D
10 128 2286G7233 W.F. 2286-0354 2S CF24 84VU 2286G7195 W.F. D
11 84VU 2286G7195 W.F. 2286-0354 2S CF24 88VU 3448G7068 W.F. D
12 88VU 3448G7068 W.F. 2286-0354 2S CF24 86VU 3161G7170 W.F. D
13 86VU 3161G7170 W.F. 2286-0354 2S CF24 86VU 3161G7167 W.F. D
14 86VU 3161G7167 W.F. 2286-0354 2S CF24 86VU 3152G7145 W.F. D
15 86VU 1860VT SH 2286G7194 2S TK26 128 36VC SH D
16 86VU 1860VT 29G 2286-7194 B 2S TK26 128 36VC 16 D
17 86VU 1860VT 29H 2286-7194 R 2S TK26 128 36VC 15 D
18 86VU 1860VT SH 2286G7195 2S TK26 84VU 1CA2-AB SH D
19 86VU 1860VT 29F 2286-7195 B 2S TK26 84VU 1CA2-AB 5K D
20 86VU 1860VT 29C 2286-7195 R 2S TK26 84VU 1CA2-AB 5J D
21 86VU 1860VT SH 2286G7233 2S TK26 128 36VC SH D
22 86VU 1860VT 29N 2286-7233 B 2S TK26 128 36VC 12 D
23 86VU 1860VT 29R 2286-7233 R 2S TK26 128 36VC 11 D
24
25
D = DELETED WIRE
SH = SHIELD
W.F. = WIRE FERRULE
CONF 004
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 86VU 1860VT SH 3161G7167 2S TK26 85VU 1WT3-AA SH D
2 85VU 1WT3-AA 2G 3161-7167 B 2S TK26 86VU 1860VT 29M D
3 86VU 1860VT 29K 3161-7167 R 2S TK26 85VU 1WT3-AA 2F D
4 86VU 1860VT SH 3411G7171 2S TK26 128 152VC SH D
5 86VU 1860VT 29D 3411-7171 B 2S TK26 128 152VC 20 D
6 86VU 1860VT 29A 3411-7171 R 2S TK26 128 152VC 14 D
7 86VU 1860VT SH 3448G7068 2S TK26 88VU 1WZ-AA SH D
8 88VU 1WZ-AA 9D 3448-7068 B 2S TK26 86VU 1860VT 29X D
9 86VU 1860VT 29T 3448-7068 R 2S TK26 88VU 1WZ-AA 9C D
10 86VU 2286G7194 W.F. 2286-0349 2S CF24 128 36VC 17 D
11 86VU 2286G7233 W.F. 2286-0450 2S CF24 128 36VC 13 D
12 128 3411G7171 W.F. 3411-0301 2S CF24 128 152VC 13 D
13
14
15
16
17
18
19
20
21
22
23
24
25
D = DELETED WIRE
SH = SHIELD
W.F. = WIRE FERRULE
CONF 004
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 86VU 1860VT SH E0718-02-30 3152G7145 2S TK26 1500 60 86VU 1WW2-AE SH E0718-02-30 (c) A (b) (d)(1)
2 86VU 1860VT 37P EN3155-016M2222 3152-7145 B 2S TK26 1500 60 86VU 1WW2-AE 8B E0170FA2200 (c) A (b) (d)(1)
3 86VU 1860VT 36P EN3155-016M2222 3152-7145 R 2S TK26 1500 60 86VU 1WW2-AE 8A E0170FA2200 (c) A (b) (d)(1)
4 86VU 1860VT SH E0718-02-30 3161G7170 2S TK26 1000 40 86VU 1WT2-AA SH E0718-02-30 (c) A (b) (d)(1)
5 86VU 1860VT 37G EN3155-016M2222 3161-7170 B 2S TK26 1000 40 86VU 1WT2-AA 2G E0170FA2200 (c) A (b) (d)(1)
6 86VU 1860VT 36G EN3155-016M2222 3161-7170 R 2S TK26 1000 40 86VU 1WT2-AA 2F E0170FA2200 (c) A (b) (d)(1)
7 86VU 3152G7145 W.F. E0160-1-0H 2286-0354 2S CF24 5000 200 128 3411G7171 W.F. E0160-1-0H (c) A (b) (d)(1)
8 128 3411G7171 W.F. E0160-1-0H 2286-0354 2S CF24 5000 200 128 2286G7194 W.F. E0160-1-0H (c) A (b) (d)(1)
9 128 2286G7194 W.F. E0160-1-0H 2286-0354 2S CF24 5000 200 86VU 2286G7233 W.F. E0160-1-0H (c) A (b) (d)(1)
10 86VU 2286G7233 W.F. E0160-1-0H 2286-0354 2S CF24 5000 200 84VU 2286G7195 W.F. E0160-1-0H (c) A (b) (d)(1)
11 84VU 2286G7195 W.F. E0160-1-0H 2286-0354 2S CF24 5000 200 88VU 3448G7068 W.F. E0160-1-0H (c) A (b) (d)(1)
12 88VU 3448G7068 W.F. E0160-1-0H 2286-0354 2S CF24 5000 200 86VU 3161G7170 W.F. E0160-1-0H (c) A (b) (d)(1)
13 86VU 3161G7170 W.F. E0160-1-0H 2286-0354 2S CF24 5000 200 86VU 3161G7167 W.F. E0160-1-0H (c) A (b) (d)(1)
14 86VU 3161G7167 W.F. E0160-1-0H 2286-0354 2S CF24 5000 200 86VU 3452G7082 W.F. E0160-1-0H (c) A (b) (d)(1)
15 86VU 3452G7082 W.F. E0160-1-0H 2286-0354 2S CF24 5000 200 86VU 3452G7081 W.F. E0160-1-0H (c) A (b) (d)(1)
16 86VU 3452G7081 W.F. E0160-1-0H 2286-0354 2S CF24 5000 200 86VU 3152G7145 W.F. E0160-1-0H (c) A (b) (d)(1)
17 86VU 1860VT SH E0718-02-30 2286G7194 2S TK26 3000 120 128 36VC SH E0718-02-30 (c) A (b) (d)(1)
18 86VU 1860VT 37L EN3155-016M2222 2286-7194 B 2S TK26 3000 120 128 36VC 16 EN3155-008M2222 (c) A (b) (d)(1)
19 86VU 1860VT 36L EN3155-016M2222 2286-7194 R 2S TK26 3000 120 128 36VC 15 EN3155-008M2222 (c) A (b) (d)(1)
20 86VU 1860VT SH E0718-02-30 2286G7195 2S TK26 3000 120 84VU 1CA2-AB SH E0718-02-30 (c) A (b) (d)(1)
21 86VU 1860VT 37M EN3155-016M2222 2286-7195 B 2S TK26 3000 120 84VU 1CA2-AB 5K E0170FA2200 (c) A (b) (d)(1)
22 86VU 1860VT 36M EN3155-016M2222 2286-7195 R 2S TK26 3000 120 84VU 1CA2-AB 5J E0170FA2200 (c) A (b) (d)(1)
23 86VU 1860VT SH E0718-02-30 2286G7233 2S TK26 3000 120 128 36VC SH E0718-02-30 (c) A (b) (d)(1)
24 86VU 1860VT 37N EN3155-016M2222 2286-7233 B 2S TK26 3000 120 128 36VC 12 EN3155-008M2222 (c) A (b) (d)(1)
25 86VU 1860VT 36N EN3155-016M2222 2286-7233 R 2S TK26 3000 120 128 36VC 11 EN3155-008M2222 (c) A (b) (d)(1)
(c) = BUNDLE D9000095461195 W.F. = WIRE FERRULE (1) = (b) = D9000095460995 OR
A = ADDED WIRE (c) = D9000095461195 OR
SH = SHIELD (d) = D9000095461295
CONF 004
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 86VU 1860VT SH E0718-02-30 3161G7167 2S TK26 3000 120 85VU 1WT3-AA SH E0718-02-30 (c) A (b) (d)(1)
2 85VU 1WT3-AA 2G E0170FA2200 3161-7167 B 2S TK26 3000 120 86VU 1860VT 37F EN3155-016M2222 (c) A (b) (d)(1)
3 86VU 1860VT 36F EN3155-016M2222 3161-7167 R 2S TK26 3000 120 85VU 1WT3-AA 2F E0170FA2200 (c) A (b) (d)(1)
4 86VU 1860VT SH E0718-02-30 3411G7171 2S TK26 4500 180 128 152VC SH E0718-02-30 (c) A (b) (d)(1)
5 86VU 1860VT 37X EN3155-016M2222 3411-7171 B 2S TK26 4500 180 128 152VC 20 EN3155-008M2222 (c) A (b) (d)(1)
6 86VU 1860VT 36X EN3155-016M2222 3411-7171 R 2S TK26 4500 180 128 152VC 14 EN3155-008M2222 (c) A (b) (d)(1)
7 86VU 1860VT SH E0718-02-30 3448G7068 2S TK26 2500 100 88VU 1WZ-AA SH E0718-02-30 (c) A (b) (d)(1)
8 88VU 1WZ-AA 9D E0170FA2200 3448-7068 B 2S TK26 2500 100 86VU 1860VT 37U EN3155-016M2222 (c) A (b) (d)(1)
9 86VU 1860VT 36U EN3155-016M2222 3448-7068 R 2S TK26 2500 100 88VU 1WZ-AA 9C E0170FA2200 (c) A (b) (d)(1)
10 86VU 1860VT SH E0718-02-30 3452G7081 2S TK26 3500 140 82VU 1SH2-AB SH E0718-02-30 (c) A (b) (d)(1)
11 82VU 1SH2-AB 3G E0170FA2200 3452-7081 B 2S TK26 3500 140 86VU 1860VT 37D EN3155-016M2222 (c) A (b) (d)(1)
12 86VU 1860VT 36D EN3155-016M2222 3452-7081 R 2S TK26 3500 140 82VU 1SH2-AB 3F E0170FA2200 (c) A (b) (d)(1)
13 86VU 1860VT SH E0718-02-30 3452G7082 2S TK26 3500 140 82VU 1SH2-AA SH E0718-02-30 (c) A (b) (d)(1)
14 82VU 1SH2-AA 7B E0170FA2200 3452-7082 B 2S TK26 3500 140 86VU 1860VT 37E EN3155-016M2222 (c) A (b) (d)(1)
15 86VU 1860VT 36E EN3155-016M2222 3452-7082 R 2S TK26 3500 140 82VU 1SH2-AA 7A E0170FA2200 (c) A (b) (d)(1)
16 86VU 2286G7194 W.F. E0160-1-0H 2286-0349 2S CF24 500 20 128 36VC 17 EN3155-008M2222 (c) A (b) (d)(1)
17 86VU 3411G7171 W.F. E0160-1-0H 3411-0301 2S CF24 500 20 128 152VC 13 EN3155-008M2222 (c) A (b) (d)(1)
18 128 2286G7233 W.F. E0160-1-0H 2286-0450 2S CF24 500 20 128 36VC 13 EN3155-008M2222 (c) A (b) (d)(1)
19
20
21
22
23
24
25
(c) = BUNDLE D9000095461195 W.F. = WIRE FERRULE (1) = (b) = D9000095460995 OR
A = ADDED WIRE (c) = D9000095461195 OR
SH = SHIELD (d) = D9000095461295
CONF 004
BEFORE
0330
34
0329
47
F.R.
32 R R
7168
33 B
A 106VC
128 AE
U R 7E
3152-7209
34 B 7F
3411-1628
T R 9C
3152-7208
F.R. B 9D
1WW2
32 R S FWC-2
3411-7418 86VU
33 B 128
A 154VC
128
B
1862VT
128
86VU
DELETED WIRE F.R. FOR REFERENCE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 3436
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK26 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 2M
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-34XX1620-A-FAPE3-00MGD-A-002-01
CONF 004
AFTER
0330
54 AA
34 A R 6H
3452-7083
0329
B 6J
F.R.
1SH2
32 R B XPDR
7168 ATC-2
33 B 82VU
128
A 106VC
128 AE
C R 7E
3152-7209
B 7F
G
D R 9C
3152-7208
B 9D
F
1WW2
E FWC-2
86VU
128
H
34
3411-1628
J
F.R.
P
32 R
3411-7418 K
33 B
A 154VC N
128
M
1862VT
128
86VU
NEW WIRE STOWED WIRE F.R. FOR REFERENCE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 3436
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK26 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 2M
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-34XX1620-A-FAPE3-00MGE-A-002-01
CONF 004
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 86VU 1WW2-AE SH 3152G7208 2M TK26 86VU 1862VT SH D
2 86VU 1WW2-AE 9D 3152-7208 B 2M TK26 86VU 1862VT 47C D
3 86VU 1WW2-AE 9C 3152-7208 R 2M TK26 86VU 1862VT 47T D
4 86VU 1WW2-AE SH 3152G7209 2M TK26 86VU 1862VT SH D
5 86VU 1WW2-AE 7F 3152-7209 B 2M TK26 86VU 1862VT 47D D
6 86VU 1WW2-AE 7E 3152-7209 R 2M TK26 86VU 1862VT 47U D
7 86VU 3436G7168 W.F. 3436-0330 2M CF24 86VU 3411G7418 W.F. D
8 86VU 3411G7418 W.F. 3436-0330 2M CF24 86VU 3152G7208 W.F. D
9 86VU 3152G7208 W.F. 3436-0330 2M CF24 86VU 3152G7209 W.F. D
10 86VU 3152G7209 W.F. 3436-0330 2M CF24 86VU 3436G7168 W.F. D
11 86VU 1862VT SH 3411G7418 2M TK26 128 154VC SH D
12 86VU 1862VT 47B 3411-7418 B 2M TK26 128 154VC 33 D
13 86VU 1862VT 47S 3411-7418 R 2M TK26 128 154VC 32 D
14 86VU 1862VT SH 3436G7168 2M TK26 128 106VC SH D
15 86VU 1862VT 47A 3436-7168 B 2M TK26 128 106VC 33 D
16 86VU 1862VT 47R 3436-7168 R 2M TK26 128 106VC 32 D
17 128 3411G7418 W.F. 3411-1628 2M CF24 128 154VC 34 D
18 128 3436G7168 W.F. 3436-0329 2M CF24 128 106VC 34 D
19
20
21
22 86VU 1WW2-AE SH E0718-02-30 3152G7208 2M TK26 2000 80 86VU 1862VT SH E0718-02-30 (a) A
23 86VU 1WW2-AE 9D E0170FA2200 3152-7208 B 2M TK26 2000 80 86VU 1862VT 54L EN3155-016M2222 (a) A
24 86VU 1WW2-AE 9C E0170FA2200 3152-7208 R 2M TK26 2000 80 86VU 1862VT 54D EN3155-016M2222 (a) A
25
(a) = BUNDLE D9000095460895 SH = SHIELD
A = ADDED WIRE W.F. = WIRE FERRULE
D = DELETED WIRE
CONF 004
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 86VU 1WW2-AE SH E0718-02-30 3152G7209 2M TK26 2000 80 86VU 1862VT SH E0718-02-30 (a) A
2 86VU 1WW2-AE 7F E0170FA2200 3152-7209 B 2M TK26 2000 80 86VU 1862VT 54K EN3155-016M2222 (a) A
3 86VU 1WW2-AE 7E E0170FA2200 3152-7209 R 2M TK26 2000 80 86VU 1862VT 54C EN3155-016M2222 (a) A
4 86VU 3436G7168 W.F. E0160-1-0H 3436-0330 2M CF24 2500 100 86VU 3411G7418 W.F. E0160-1-0H (a) A
5 86VU 3411G7418 W.F. E0160-1-0H 3436-0330 2M CF24 2500 100 86VU 3152G7208 W.F. E0160-1-0H (a) A
6 86VU 3152G7208 W.F. E0160-1-0H 3436-0330 2M CF24 2500 100 86VU 3152G7209 W.F. E0160-1-0H (a) A
7 86VU 3152G7209 W.F. E0160-1-0H 3436-0330 2M CF24 2500 100 86VU 3452G7083 W.F. E0160-1-0H (a) A
8 86VU 3452G7083 W.F. E0160-1-0H 3436-0330 2M CF24 2500 100 86VU 3436G7168 W.F. E0160-1-0H (a) A
9 86VU 1862VT SH E0718-02-30 3411G7418 2M TK26 2500 100 128 154VC SH E0718-02-30 (a) A
10 86VU 1862VT 54M EN3155-016M2222 3411-7418 B 2M TK26 2500 100 128 154VC 33 EN3155-008M2222 (a) A
11 86VU 1862VT 54E EN3155-016M2222 3411-7418 R 2M TK26 2500 100 128 154VC 32 EN3155-008M2222 (a) A
12 86VU 1862VT SH E0718-02-30 3436G7168 2M TK26 3500 140 128 106VC SH E0718-02-30 (a) A
13 86VU 1862VT 54J EN3155-016M2222 3436-7168 B 2M TK26 3500 140 128 106VC 33 EN3155-008M2222 (a) A
14 86VU 1862VT 54B EN3155-016M2222 3436-7168 R 2M TK26 3500 140 128 106VC 32 EN3155-008M2222 (a) A
15 86VU 1862VT SH E0718-02-30 3452G7083 2M TK26 3500 140 82VU 1SH2-AA SH E0718-02-30 (a) A
16 82VU 1SH2-AA W.S. NSA936604CA0931 3452-7083 B 2M TK26 3500 140 86VU 1862VT W.S. NSA936604CA0931 (a) A
17 86VU 1862VT W.S. NSA936604CA0931 3452-7083 R 2M TK26 3500 140 82VU 1SH2-AA W.S. NSA936604CA0931 (a) A
18 128 3411G7418 W.F. E0160-1-0H 3411-1628 2M CF24 500 20 128 154VC 34 EN3155-008M2222 (a) A
19 128 3436G7168 W.F. E0160-1-0H 3436-0329 2M CF24 500 20 128 106VC 34 EN3155-008M2222 (a) A
20
21
22
23
24
25
(a) = BUNDLE D9000095460895 W.F. = WIRE FERRULE
A = ADDED WIRE W.S. = WIRE STOWED
SH = SHIELD
CONF 004
BEFORE
0303
F.R. 39
67 R H
F.R. 3411-7417
68 B
F.R.
A 153VC
127 AB
C R 7E
3152-7203
B 7F
F.R.
- F.R. 1WW1 FWC-1
85VU
127
F
- F.R.
1853VT
127
85VU
AFTER
0303
39 AA
T R 6H
3452-7093
B 6J
1SH1 XPDR
ATC-1
81VU
H 127
AB
C R 7E
3152-7203
- F.R. B 7F
F.R.
1WW1 FWC-1
F.R. 85VU
127
67 R U
F.R. 3411-7417
68 B G
F.R.
A 153VC F
127
- F.R.
1853VT
127
85VU
CONF 004
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 85VU 3152G7203 W.F. 3436-0303 1M CF24 85VU 3411G7417 W.F. D
2 81VU 1SH1-AA SH E0718-02-30 3452G7093 1M TK26 3500 140 85VU 1853VT SH E0718-02-30 (d) A
3 85VU 1853VT W.S. NSA936604CA0931 3452-7093 B 1M TK26 3500 140 81VU 1SH1-AA W.S. NSA936604CA0931 (d) A
4 81VU 1SH1-AA W.S. NSA936604CA0931 3452-7093 R 1M TK26 3500 140 85VU 1853VT W.S. NSA936604CA0931 (d) A
5 85VU 3152G7203 W.F. E0160-1-0H 3436-0303 1M CF24 1000 40 85VU 3452G7093 W.F. E0160-1-0H (d) A
6 85VU 3452G7093 W.F. E0160-1-0H 3436-0303 1M CF24 1000 40 127 3411G7417 W.F. E0160-1-0H (d) A
7
8
9
10 85VU 1853VT SH E0718-02-30 3152G7203 1M TK26 85VU 1WW1-AB SH E0718-02-30 F.R.
11 85VU 1853VT 39F 3152-7203 B 1M TK26 85VU 1WW1-AB 7F F.R.
12 85VU 1853VT 39C 3152-7203 R 1M TK26 85VU 1WW1-AB 7E F.R.
13 127 153VC SH E0718-02-30 3411G7417 1M TK26 85VU 1853VT SH E0718-02-30 F.R.
14 127 153VC 68 3411-7417 B 1M TK26 85VU 1853VT 39G F.R.
15 127 153VC 67 3411-7417 R 1M TK26 85VU 1853VT 39H F.R.
16
17
18
19
20
21
22
23
24
25
(d) = BUNDLE D9000095461295 F.R. = FOR REFERENCE W.S. = WIRE STOWED
A = ADDED WIRE SH = SHIELD
D = DELETED WIRE W.F. = WIRE FERRULE
CONF 004
BEFORE
41
AA F.R. V
2E B D
3161-7165 F.R. AB
2D R - F.R.
B 5B
42 3137-7066
1WT3 DMC-3 V R 5A
85VU
127 D
1TV DMU
- F.R. OR
10TV FDIMU
1851VT 87VU
127 85VU 127
0343 S
AFTER
F.R. AB
41
AA F.R. V R 5B
3137-7066
2E B D B 5A
3161-7165
2D R X
1TV DMU
Y OR
1WT3 DMC-3 10TV FDIMU
85VU - F.R. 87VU
127 127
42
V AA
D B 7B
3452-7091
X R 7A
Y AB
- F.R. B 3G
3452-7092
1851VT R 3F .
127 85VU
CONF 004
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 87VU 3137G7066 W.F. 2286S0343 1S CF24 85VU 3161G7165 W.F. D
2 85VU 3137G7066 W.F. E0160-1-0H 2286S0343 1S CF24 1500 60 81VU 3452G7091 W.F. E0160-1-0H (a) A (c) (1)
3 81VU 3452G7091 W.F. E0160-1-0H 2286S0343 1S CF24 1500 60 81VU 3452G7092 W.F. E0160-1-0H (a) A (c) (1)
4 81VU 3452G7092 W.F. E0160-1-0H 2286S0343 1S CF24 1500 60 85VU 3161G7165 W.F. E0160-1-0H (a) A (c) (1)
5 81VU 1SH1-AA SH E0718-02-30 3452G7091 1S TK26 4000 160 85VU 1851VT SH E0718-02-30 (a) A (c) (1)
6 81VU 1SH1-AA 7B E0170FA2200 3452-7091 B 1S TK26 4000 160 85VU 1851VT 41X EN3155-016M2222 (a) A (c) (1)
7 81VU 1SH1-AA 7A E0170FA2200 3452-7091 R 1S TK26 4000 160 85VU 1851VT 42X EN3155-016M2222 (a) A (c) (1)
8 81VU 1SH1-AB SH E0718-02-30 3452G7092 1S TK26 4000 160 85VU 1851VT SH E0718-02-30 (a) A (c) (1)
9 81VU 1SH1-AB 3G E0170FA2200 3452-7092 B 1S TK26 4000 160 85VU 1851VT 41Y EN3155-016M2222 (a) A (c) (1)
10 81VU 1SH1-AB 3F E0170FA2200 3452-7092 R 1S TK26 4000 160 85VU 1851VT 42Y EN3155-016M2222 (a) A (c) (1)
11
12
13
14 87VU 1TV-AB SH E0718-02-30 3137G7066 1S TK26 85VU 1851VT SH E0718-02-30 F.R.
15 87VU 1TV-AB 5B 3137-7066 B 1S TK26 85VU 1851VT 41V F.R.
16 85VU 1851VT 42V 3137-7066 R 1S TK26 87VU 1TV-AB 5A F.R.
17 85VU 1WT3-AA SH E0718-02-30 3161G7165 1S TK26 85VU 1851VT SH E0718-02-30 F.R.
18 85VU 1WT3-AA 2E 3161-7165 B 1S TK26 85VU 1851VT 41D F.R.
19 85VU 1WT3-AA 2D 3161-7165 R 1S TK26 85VU 1851VT 42D F.R.
20
21
22
23
24
25
(a) = BUNDLE D9000095460895 F.R. = FOR REFERENCE S = SAFETY WIRE
A = ADDED WIRE SH = SHIELD (1) = (a) = D9000095460895 OR
D = DELETED WIRE W.F. = WIRE FERRULE (c) = D9000095461195
CONF 004
BEFORE
76 72
1630
1626
F.R. F.R.
77 7416 R 70
TK26
78 B 71
A 11VC 153VC A
127 127
37 37
1631
1629
F.R. F.R.
2M
35 R 35
7419
TK26 B
36 36
A 106VC 154VC A
128 128
CONF 004
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 127 11VC SH 3411G7416 1M TK26 127 153VC SH D
2 127 11VC 78 3411-7416 B 1M TK26 127 153VC 71 D
3 127 11VC 77 3411-7416 R 1M TK26 127 153VC 70 D
4 128 106VC SH 3411G7419 2M TK26 128 154VC SH D
5 128 106VC 36 3411-7419 B 2M TK26 128 154VC 36 D
6 128 106VC 35 3411-7419 R 2M TK26 128 154VC 35 D
7 127 3411G7416 W.F. 3411-1626 1M CF24 127 153VC 72 D
8 128 3411G7419 W.F. 3411-1629 2M CF24 128 154VC 37 D
9 127 3411G7416 W.F. 3411-1630 1M CF24 127 11VC 76 D
10 128 3411G7419 W.F. 3411-1631 2M CF24 128 106VC 37 D
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
D = DELETED WIRE
SH = SHIELD
W.F. = WIRE FERRULE
CONF 004
AFTER
31
77 R A
7226 AA
F.R. 78 B
B R 6D
76 0437 3452-7094
- B 6E
A 11VC C F.R. -
127
H 1SH1
XPDR
ATC-1
J 81VU
70 R 127
3411-7416 -
71 B K
1813VT
3411-1626
127
F.R. 81VU
0438
72
A 153VC
127
CONF 004
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 81VU 1SH1-AA SH E0718-02-30 3452G7094 1M TK26 1500 60 81VU 1813VT SH E0718-02-30 (a) A
2 81VU 1SH1-AA W.S. NSA936604CA0931 3452-7094 B 1M TK26 1500 60 81VU 1813VT W.S. NSA936604CA0931 (a) A
3 81VU 1SH1-AA W.S. NSA936604CA0931 3452-7094 R 1M TK26 1500 60 81VU 1813VT W.S. NSA936604CA0931 (a) A
4 81VU 3436G7226 W.F. E0160-1-0H 3436-0438 1M CF24 1000 40 81VU 3452G7094 W.F. E0160-1-0H (a) A
5 81VU 3452G7094 W.F. E0160-1-0H 3436-0438 1M CF24 1000 40 81VU 3411G7416 W.F. E0160-1-0H (a) A
6 81VU 1813VT SH E0718-02-30 3411G7416 1M TK26 3500 140 127 153VC SH E0718-02-30 (a) A
7 81VU 1813VT 31K EN3155-016M2222 3411-7416 B 1M TK26 3500 140 127 153VC 71 EN3155-008M2222 (a) A
8 81VU 1813VT 31C EN3155-016M2222 3411-7416 R 1M TK26 3500 140 127 153VC 70 EN3155-008M2222 (a) A
9 81VU 1813VT SH E0718-02-30 3436G7226 1M TK26 2000 80 127 11VC SH E0718-02-30 (a) A
10 81VU 1813VT 31H EN3155-016M2222 3436-7226 B 1M TK26 2000 80 127 11VC 78 EN3155-008M2222 (a) A
11 81VU 1813VT 31A EN3155-016M2222 3436-7226 R 1M TK26 2000 80 127 11VC 77 EN3155-008M2222 (a) A
12 127 3411G7416 W.F. E0160-1-0H 3411-1626 1M CF24 500 20 127 153VC 72 EN3155-008M2222 (a) A
13 127 3436G7226 W.F. E0160-1-0H 3436-0437 1M CF24 500 20 127 11VC 76 EN3155-008M2222 (a) A
14
15
16
17
18
19
20
21
22
23
24
25
(a) = BUNDLE D9000095460895 W.F. = WIRE FERRULE
A = ADDED WIRE W.S. = WIRE STOWED
SH = SHIELD
CONF 004
AFTER
37
3411-1629
0427
F.R.
39
35 R B
3411-7419
36 B
A 154VC
128 AA
A R 6D
3452-7084
B 6E
-
1SH2 XPDR
35 R C ATC-2
7223 82VU
36 B 128
0428
F.R.
37
A 106VC -
128
K
1822VT
128
82VU
CONF 004
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 82VU 1SH2-AA SH E0718-02-30 3452G7084 2M TK26 1000 40 82VU 1822VT SH E0718-02-30 (a) A
2 82VU 1822VT W.S. NSA936604CA0931 3452-7084 B 2M TK26 1000 40 82VU 1SH2-AA W.S. NSA936604CA0931 (a) A
3 82VU 1SH2-AA W.S. NSA936604CA0931 3452-7084 R 2M TK26 1000 40 82VU 1822VT W.S. NSA936604CA0931 (a) A
4 82VU 3436G7223 W.F. E0160-1-0H 3436-0427 2M CF24 1000 40 82VU 3452G7084 W.F. E0160-1-0H (a) A
5 82VU 3452G7084 W.F. E0160-1-0H 3436-0427 2M CF24 1000 40 82VU 3411G7419 W.F. E0160-1-0H (a) A
6 82VU 1822VT SH E0718-02-30 3411G7419 2M TK26 3500 140 128 154VC SH E0718-02-30 (a) A
7 82VU 1822VT 39J EN3155-016M2222 3411-7419 B 2M TK26 3500 140 128 154VC 36 EN3155-008M2222 (a) A
8 82VU 1822VT 39B EN3155-016M2222 3411-7419 R 2M TK26 3500 140 128 154VC 35 EN3155-008M2222 (a) A
9 82VU 1822VT SH E0718-02-30 3436G7223 2M TK26 3000 120 128 106VC SH E0718-02-30 (a) A
10 82VU 1822VT 39K EN3155-016M2222 3436-7223 B 2M TK26 3000 120 128 106VC 36 EN3155-008M2222 (a) A
11 82VU 1822VT 39C EN3155-016M2222 3436-7223 R 2M TK26 3000 120 128 106VC 35 EN3155-008M2222 (a) A
12 128 3411G7419 W.F. E0160-1-0H 3411-1629 2M CF24 500 20 128 154VC 37 EN3155-008M2222 (a) A
13 128 3436G7223 W.F. E0160-1-0H 3436-0428 2M CF24 500 20 128 106VC 37 EN3155-008M2222 (a) A
14
15
16
17
18
19
20
21
22
23
24
25
(a) = BUNDLE D9000095460895 W.F. = WIRE FERRULE
A = ADDED WIRE W.S. = WIRE STOWED
SH = SHIELD
CONF 004
AFTER
4621-0210
30 AA
S R 2C
3452-7096
B 2D
T
AA 1SH2
F.R. -
2J R R XPDR
ATC-2
4621-7121 31 82VU
2K B R 128
1TX1 ATSU-1 B1 AA
4621-0211 S
81VU R 2C
127 - 3452-7097
739VG T B 2D
1 127 F.R. -
81VU 1813VT
127
81VU 1SH1
XPDR
ATC-1
81VU
127
CONF 004
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 81VU 1813VT SH E0718-02-30 3452G7097 1S TK26 1500 60 81VU 1SH1-AA SH E0718-02-30 (d) A
2 81VU 1813VT 31T EN3155-016M2222 3452-7097 B 1S TK26 1500 60 81VU 1SH1-AA 2D E0170FA2200 (d) A
3 81VU 1813VT 30T EN3155-016M2222 3452-7097 R 1S TK26 1500 60 81VU 1SH1-AA 2C E0170FA2200 (d) A
4 81VU 1813VT SH E0718-02-30 4621G7121 1S TK26 1000 40 81VU 1TX1-AA SH E0718-02-30 (d) A
5 81VU 1813VT 31R EN3155-016M2222 4621-7121 B 1S TK26 1000 40 81VU 1TX1-AA 2K E0170FA2200 (d) A
6 81VU 1813VT 30R EN3155-016M2222 4621-7121 R 1S TK26 1000 40 81VU 1TX1-AA 2J E0170FA2200 (d) A
7 81VU 4621G7121 W.F. E0160-1-0H 4621-0210 1S CF24 1000 40 81VU 3452G7096 W.F. E0160-1-0H (d) A
8 81VU 3452G7096 W.F. E0160-1-0H 4621-0210 1S CF24 1000 40 81VU 3452G7097 W.F. E0160-1-0H (d) A
9 81VU 4621G7121 W.F. E0160-1-0H 4621-0211 1S CF24 1500 60 81VU 739VG GND EN3155-015F2018 (d) A
10 81VU 1813VT SH E0718-02-30 3452G7096 1S TK26 3000 120 82VU 1SH2-AA SH E0718-02-30 (d) A
11 81VU 1813VT 31S EN3155-016M2222 3452-7096 B 1S TK26 3000 120 82VU 1SH2-AA 2D E0170FA2200 (d) A
12 81VU 1813VT 30S EN3155-016M2222 3452-7096 R 1S TK26 3000 120 82VU 1SH2-AA 2C E0170FA2200 (d) A
13
14
15
16
17
18
19
20
21
22
23
24
25
(d) = BUNDLE D9000095461295 W.F. = WIRE FERRULE
A = ADDED WIRE GND = GROUND
SH = SHIELD
CONF 001
(2) Task A320-A-34-XX-1620-02001-920A-A - Remove the Shelves 95VU and
96VU, for Access
Job Set-Up Information
Working Area
Man-hours 5.00 h
Minimum Number of person 1
Elapsed Time 5.00 h
Skills Electrical
Referenced Information
Manuals/Drawings References/Sheets
Task 21-31-34-000-001
Task 21-43-34-000-002
Task 21-61-34-000-001
AMM
Task 24-22-33-000-001
Task 34-36-31-000-001
Task 36-11-34-000-001
Procedure
(a) Standard Practices:
1 Tag all the parts you must remove and retain to make the subsequent
installation easier.
2 Put all the retained hardware in identified plastic bags and attach the bags
to the related unit.
(b) Remove the shelf Electrical Panel 95VU
1 Remove and retain the MMR ( FIN 40RT1), refer to Ref. AMM Task
34-36-31-000-001.
2 Remove and retain the EGIU ( FIN 22XU1), refer to Ref. AMM Task
24-22-33-000-001.
3 Remove and retain the BMC ( FIN 1HA1), refer to Ref. AMM Task
36-11-34-000-001.
4 Remove and retain the CPC ( FIN 11HL), refer to Ref. AMM Task
21-31-34-000-001.
5 Remove and retain the PC ( FIN 7HH), refer to Ref. AMM Task
21-61-34-000-001.
6 Put blanking caps on the disconnected connectors.
7 Disconnect the bonding braid.
8 Remove and retain the attachment hardware from the shelf.
9 Remove the shelf Electrical Panel 95VU and install it on the bench.
Man-hours 5.00 h
Minimum Number of person 1
Elapsed Time 5.00 h
Skills Electrical
Referenced Information
Manuals/Drawings References/Sheets
Task 21-31-34-000-001
Task 21-61-34-000-001
AMM
Task 34-36-31-000-001
Task 36-11-34-000-001
Procedure
(a) Standard Practices:
1 Tag all the parts you must remove and retain to make the subsequent
installation easier.
2 Put all the retained hardware in identified plastic bags and attach the bags
to the related unit.
Man-hours 2.00 h
Minimum Number of person 2
Elapsed Time 1.00 h
Skills Electrical
Material necessary to do the job
Part kit 341620A02R00
ITEM PART No. QTY (UM) KEYWORD DRAWING SEE NOTES
D9000095460895 1 BUNDLE
NSA935401-05 30 TIE
NSA935401-08 30 TIE
NSA935401-13 30 TIE
Referenced Information
Manuals/Drawings References/Sheets
20-33-00
20-33-44
ESPM
20-52-21
20-56-51
Procedure
(a) Standard Practices:
1 For the general installation of electrical wire harnesses, refer to Ref. ESPM
20-33-00.
2 For the cable tie application and tooling, refer to Ref. ESPM 20-33-44 and
Ref. ESPM 20-56-51.
3 To install new wires, cut them to the necessary length, attach the terminals
and connect them.
(b) Modify the wiring in the shelf Electrical Panel 95VU
Refer to Ref. ESPM 20-33-00
1 Remove the wire(s) as shown on this(these) wiring diagram(s) and the
related hook-up chart(s):
- Ref. Fig. WI and Ref. Fig. HI.
2 Install the wire(s) as shown on this(these) wiring diagram(s) and the
related hook-up chart(s):
- Ref. Fig. WI and Ref. Fig. HI, supplied in:
1 BUNDLE D9000095460895
3 Attach the wires with:
Refer to Ref. ESPM 20-33-44 and Ref. ESPM 20-56-51
15 TIE-CABLE NSA935401-05
15 TIE-CABLE NSA935401-08
15 TIE-CABLE NSA935401-13
4 Do a continuity test of the new and/or modified electrical wires, refer to
Ref. ESPM 20-52-21.
(c) Modify the wiring in the shelf Electrical Panel 96VU
Refer to Ref. ESPM 20-33-00
1 Remove the wire(s) as shown on this(these) wiring diagram(s) and the
related hook-up chart(s):
- Ref. Fig. WI and Ref. Fig. HI.
2 Install the wire(s) as shown on this(these) wiring diagram(s) and the
related hook-up chart(s):
- Ref. Fig. WI and Ref. Fig. HI, supplied in:
1 BUNDLE D9000095460895
3 Attach the wires with:
Refer to Ref. ESPM 20-33-44 and Ref. ESPM 20-56-51
15 TIE-CABLE NSA935401-05
15 TIE-CABLE NSA935401-08
15 TIE-CABLE NSA935401-13
4 Do a continuity test of the new and/or modified electrical wires, refer to
Ref. ESPM 20-52-21.
CONF 001
BEFORE
47
1641
AB F.R.
7E R 45
7424
7F B 46
243VC A
95VU 121
40RT1 MMR-1
95VU
121 1643
F.R.
B1
661VG
121
95VU
40
1642
AB F.R.
2M
7E R 38
7425
7F B 39
244VC A
96VU 122
40RT2 MMR-2
96VU
122 1644
F.R.
B2
660VG
122
96VU
CONF 001
AFTER
AB
7E R 45
7224
7F B 46 F.R.
0434 47
AB
2M
7E R 38
7221
7F B 39 F.R.
0431 40
CONF 001
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 95VU 40RT1-AB SH 3411G7424 1M TK24 95VU 243VC SH D
2 95VU 40RT1-AB 7F 3411-7424 B 1M TK24 95VU 243VC 46 D
3 95VU 40RT1-AB 7E 3411-7424 R 1M TK24 95VU 243VC 45 D
4 96VU 40RT2-AB SH 3411G7425 2M TK24 96VU 244VC SH D
5 96VU 40RT2-AB 7F 3411-7425 B 2M TK24 96VU 244VC 39 D
6 96VU 40RT2-AB 7E 3411-7425 R 2M TK24 96VU 244VC 38 D
7 95VU 3411G7424 W.F. 3411-1641 1M CF24 95VU 243VC 47 D
8 96VU 3411G7425 W.F. 3411-1642 2M CF24 96VU 244VC 40 D
9 95VU 3411G7424 W.F. 3411-1643 1M CF24 95VU 661VG GND D
10 96VU 3411G7425 W.F. 3411-1644 2M CF24 96VU 660VG GND D
11
12
13
14 95VU 40RT1-AB SH E0718-02-30 3436G7224 1M TK24 1500 60 95VU 243VC SH E0718-02-30 (a) A
15 95VU 40RT1-AB 7F E0170FA2200 3436-7224 B 1M TK24 1500 60 95VU 243VC 46 EN3155-008M2222 (a) A
16 95VU 40RT1-AB 7E E0170FA2200 3436-7224 R 1M TK24 1500 60 95VU 243VC 45 EN3155-008M2222 (a) A
17 96VU 40RT2-AB SH E0718-02-30 3436G7221 2M TK24 1500 60 96VU 244VC SH E0718-02-30 (a) A
18 96VU 40RT2-AB 7F E0170FA2200 3436-7221 B 2M TK24 1500 60 96VU 244VC 39 EN3155-008M2222 (a) A
19 96VU 40RT2-AB 7E E0170FA2200 3436-7221 R 2M TK24 1500 60 96VU 244VC 38 EN3155-008M2222 (a) A
20 96VU 3436G7221 W.F. E0160-1-0H 3436-0430 2M CF24 1500 60 96VU 660VG GND EN3155-015F2018 (a) A
21 96VU 3436G7221 W.F. E0160-1-0H 3436-0431 2M CF24 500 20 96VU 244VC 40 EN3155-008M2222 (a) A
22 95VU 3436G7224 W.F. E0160-1-0H 3436-0433 1M CF24 1500 60 95VU 661VG GND EN3155-015F2018 (a) A
23 95VU 3436G7224 W.F. E0160-1-0H 3436-0434 1M CF24 500 20 95VU 243VC 47 EN3155-008M2222 (a) A
24
25
(a) = BUNDLE D9000095460895 SH = SHIELD
A = ADDED WIRE W.F. = WIRE FERRULE
D = DELETED WIRE GND = GROUND
Man-hours 2.00 h
Minimum Number of person 2
Elapsed Time 1.00 h
Skills Electrical
Material necessary to do the job
Part kit 341620A02R00
ITEM PART No. QTY (UM) KEYWORD DRAWING SEE NOTES
D9000095460895 1 BUNDLE
NSA935401-05 30 TIE
NSA935401-08 30 TIE
NSA935401-13 30 TIE
Referenced Information
Manuals/Drawings References/Sheets
20-33-00
20-33-44
ESPM
20-52-21
20-56-51
Procedure
(a) Standard Practices:
1 For the general installation of electrical wire harnesses, refer to Ref. ESPM
20-33-00.
2 For the cable tie application and tooling, refer to Ref. ESPM 20-33-44 and
Ref. ESPM 20-56-51.
3 To install new wires, cut them to the necessary length, attach the terminals
and connect them.
(b) Modify the wiring in the shelf Electrical Panel 95VU
Refer to Ref. ESPM 20-33-00
1 Remove the wire(s) as shown on this(these) wiring diagram(s) and the
related hook-up chart(s):
- Ref. Fig. WI and Ref. Fig. HI.
2 Install the wire(s) as shown on this(these) wiring diagram(s) and the
related hook-up chart(s):
- Ref. Fig. WI and Ref. Fig. HI, supplied in:
1 BUNDLE D9000095460895
3 Attach the wires with:
Refer to Ref. ESPM 20-33-44 and Ref. ESPM 20-56-51
15 TIE-CABLE NSA935401-05
15 TIE-CABLE NSA935401-08
15 TIE-CABLE NSA935401-13
4 Do a continuity test of the new and/or modified electrical wires, refer to
Ref. ESPM 20-52-21.
(c) Modify the wiring in the shelf Electrical Panel 96VU
Refer to Ref. ESPM 20-33-00
1 Remove the wire(s) as shown on this(these) wiring diagram(s) and the
related hook-up chart(s):
- Ref. Fig. WI and Ref. Fig. HI.
2 Install the wire(s) as shown on this(these) wiring diagram(s) and the
related hook-up chart(s):
- Ref. Fig. WI and Ref. Fig. HI, supplied in:
1 BUNDLE D9000095460895
3 Attach the wires with:
Refer to Ref. ESPM 20-33-44 and Ref. ESPM 20-56-51
15 TIE-CABLE NSA935401-05
15 TIE-CABLE NSA935401-08
15 TIE-CABLE NSA935401-13
4 Do a continuity test of the new and/or modified electrical wires, refer to
Ref. ESPM 20-52-21.
BEFORE
47
1641
AB F.R.
7E R 45
7424
7F B 46
243VC A
95VU 121
40RT1 MMR-1
95VU
121 1643
F.R.
B1
661VG
121
95VU
40
1642
AB F.R.
2M
7E R 38
7425
7F B 39
244VC A
96VU 122
40RT2 MMR-2
96VU
122 1644
F.R.
B2
660VG
122
96VU
AFTER
AB
7E R 45
7224
7F B 46 F.R.
0434 47
AB
2M
7E R 38
7221
7F B 39 F.R.
0431 40
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 95VU 40RT1-AB SH 3411G7424 1M TK24 95VU 243VC SH D
2 95VU 40RT1-AB 7F 3411-7424 B 1M TK24 95VU 243VC 46 D
3 95VU 40RT1-AB 7E 3411-7424 R 1M TK24 95VU 243VC 45 D
4 96VU 40RT2-AB SH 3411G7425 2M TK24 96VU 244VC SH D
5 96VU 40RT2-AB 7F 3411-7425 B 2M TK24 96VU 244VC 39 D
6 96VU 40RT2-AB 7E 3411-7425 R 2M TK24 96VU 244VC 38 D
7 95VU 3411G7424 W.F. 3411-1641 1M CF24 95VU 243VC 47 D
8 96VU 3411G7425 W.F. 3411-1642 2M CF24 96VU 244VC 40 D
9 95VU 3411G7424 W.F. 3411-1643 1M CF24 95VU 661VG GND D
10 96VU 3411G7425 W.F. 3411-1644 2M CF24 96VU 660VG GND D
11
12
13
14 95VU 40RT1-AB SH E0718-02-30 3436G7224 1M TK24 1500 60 95VU 243VC SH E0718-02-30 (a) A
15 95VU 40RT1-AB 7F E0170FA2200 3436-7224 B 1M TK24 1500 60 95VU 243VC 46 EN3155-008M2222 (a) A
16 95VU 40RT1-AB 7E E0170FA2200 3436-7224 R 1M TK24 1500 60 95VU 243VC 45 EN3155-008M2222 (a) A
17 96VU 40RT2-AB SH E0718-02-30 3436G7221 2M TK24 1500 60 96VU 244VC SH E0718-02-30 (a) A
18 96VU 40RT2-AB 7F E0170FA2200 3436-7221 B 2M TK24 1500 60 96VU 244VC 39 EN3155-008M2222 (a) A
19 96VU 40RT2-AB 7E E0170FA2200 3436-7221 R 2M TK24 1500 60 96VU 244VC 38 EN3155-008M2222 (a) A
20 96VU 3436G7221 W.F. E0160-1-0H 3436-0430 2M CF24 1500 60 96VU 660VG GND EN3155-015F2018 (a) A
21 96VU 3436G7221 W.F. E0160-1-0H 3436-0431 2M CF24 500 20 96VU 244VC 40 EN3155-008M2222 (a) A
22 95VU 3436G7224 W.F. E0160-1-0H 3436-0433 1M CF24 1500 60 95VU 661VG GND EN3155-015F2018 (a) A
23 95VU 3436G7224 W.F. E0160-1-0H 3436-0434 1M CF24 500 20 95VU 243VC 47 EN3155-008M2222 (a) A
24
25
(a) = BUNDLE D9000095460895 SH = SHIELD
A = ADDED WIRE W.F. = WIRE FERRULE
D = DELETED WIRE GND = GROUND
CONF 001
(4) Task A320-A-34-XX-1620-04001-920A-A - Install the Shelves 95VU and 96VU
Job Set-Up Information
Working Area
Man-hours 5.00 h
Minimum Number of person 1
Elapsed Time 5.00 h
Skills Electrical
Referenced Information
Manuals/Drawings References/Sheets
Task 21-31-34-400-001
Task 21-43-34-400-002
Task 21-61-34-400-001
AMM
Task 24-22-33-400-002
Task 34-36-31-400-001
Task 36-11-34-400-001
Procedure
(a) Standard Practices:
1 Tag all the parts you must remove and retain to make the subsequent
installation easier.
2 Put all the retained hardware in identified plastic bags and attach the bags
to the related unit.
(b) Install the shelf Electrical Panel 95VU
1 Install the shelf Electrical Panel 95VU on aircraft.
2 Attach the shelf Electrical Panel 95VU and connect the bonding braid with
the hardware retained at removal.
3 Do the electrical bonding on the shelf attachment.
4 Connect the related connectors.
5 Install the PC ( FIN 7HH) retained at removal, refer to Ref. AMM Task
21-61-34-400-001.
6 Install the CPC ( FIN 11HL) retained at removal, refer to Ref. AMM Task
21-31-34-400-001.
7 Install the BMC ( FIN 1HA1) retained at removal, refer to Ref. AMM Task
36-11-34-400-001.
8 Install the EGIU ( FIN 22XU1) retained at removal, refer to Ref. AMM Task
24-22-33-400-002.
9 Install the MMR ( FIN 40RT1) retained at removal, refer to Ref. AMM Task
34-36-31-400-001.
Man-hours 5.00 h
Minimum Number of person 1
Elapsed Time 5.00 h
Skills Electrical
Referenced Information
Manuals/Drawings References/Sheets
Task 21-31-34-400-001
Task 21-61-34-400-001
AMM
Task 34-36-31-400-001
Task 36-11-34-400-001
Procedure
(a) Standard Practices:
1 Tag all the parts you must remove and retain to make the subsequent
installation easier.
2 Put all the retained hardware in identified plastic bags and attach the bags
to the related unit.
Man-hours 2.00 h
Minimum Number of person 1
Elapsed Time 2.00 h
Skills Electrical
Manuals/Drawings References/Sheets
20-33-00
20-33-44
ESPM
20-52-21
20-56-51
Procedure
(a) Standard Practices:
1 For the general installation of electrical wire harnesses, refer to Ref. ESPM
20-33-00.
2 For the cable tie application and tooling, refer to Ref. ESPM 20-33-44 and
Ref. ESPM 20-56-51.
3 To install new wires, cut them to the necessary length, attach the terminals
and connect them.
(b) Modify the wiring between the FWD electronics rack Electrical Panel 90VU and
the aft electronics rack Electrical Panel 80VU
Refer to Ref. ESPM 20-33-00
1 Remove the wire(s) as shown on this(these) wiring diagram(s) and the
related hook-up chart(s):
- Ref. Fig. WL and Ref. Fig. HL.
2 Install the wire(s) as shown on this(these) wiring diagram(s) and the
related hook-up chart(s):
- Ref. Fig. WL and Ref. Fig. HL, supplied in:
1 BUNDLE D9000095460895
3 Attach the wires with:
Refer to Ref. ESPM 20-33-44 and Ref. ESPM 20-56-51
BEFORE
47 76
1634
1632
F.R. F.R.
45 R 77
7420
46 B 78
243VC A A 11VC
95VU 121 127
40 37
1635
1633
F.R. F.R.
2M
38 R 35
7421
39 B 36
244VC A A 106VC
96VU 122 128
AFTER
45 R 77
7225
F.R. 46 B 78 F.R.
47 0435 0436 76
243VC A A 11VC
95VU 121 127
2M
38 R 35
7222
F.R. 39 B 36 F.R.
40 0432 0429 37
244VC A A 106VC
96VU 122 128
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
1 95VU 3411G7420 W.F. 3411-1634 1M CF24 95VU 243VC-A 47 D
2 96VU 3411G7421 W.F. 3411-1635 2M CF24 96VU 244VC-A 40 D
3 95VU 243VC-A SH 3411G7420 1M TK24 127 11VC-A SH D
4 95VU 243VC-A 46 3411-7420 B 1M TK24 127 11VC-A 78 D
5 95VU 243VC-A 45 3411-7420 R 1M TK24 127 11VC-A 77 D
6 96VU 244VC-A SH 3411G7421 2M TK24 128 106VC-A SH D
7 96VU 244VC-A 39 3411-7421 B 2M TK24 128 106VC-A 36 D
8 96VU 244VC-A 38 3411-7421 R 2M TK24 128 106VC-A 35 D
9 127 3411G7420 W.F. 3411-1632 1M CF24 127 11VC-A 76 D
10 128 3411G7421 W.F. 3411-1633 2M CF24 128 106VC-A 37 D
11
12
13
14 96VU 3436G7222 W.F. E0160-1-0H 3436-0432 2M CF24 500 20 96VU 244VC-A 40 EN3155-003F2222 (a) A
15 95VU 3436G7225 W.F. E0160-1-0H 3436-0435 1M CF24 500 20 95VU 243VC-A 47 EN3155-003F2222 (a) A
16 95VU 243VC-A SH E0718-02-30 3436G7225 1M TK24 12000 480 127 11VC-A SH E0718-02-30 (a) A
17 95VU 243VC-A 46 EN3155-003F2222 3436-7225 B 1M TK24 12000 480 127 11VC-A 78 EN3155-003F2222 (a) A
18 95VU 243VC-A 45 EN3155-003F2222 3436-7225 R 1M TK24 12000 480 127 11VC-A 77 EN3155-003F2222 (a) A
19 96VU 244VC-A SH E0718-02-30 3436G7222 2M TK24 12000 480 128 106VC-A SH E0718-02-30 (a) A
20 96VU 244VC-A 39 EN3155-003F2222 3436-7222 B 2M TK24 12000 480 128 106VC-A 36 EN3155-003F2222 (a) A
21 96VU 244VC-A 38 EN3155-003F2222 3436-7222 R 2M TK24 12000 480 128 106VC-A 35 EN3155-003F2222 (a) A
22 128 3436G7222 W.F. E0160-1-0H 3436-0429 2M CF24 500 20 128 106VC-A 37 EN3155-003F2222 (a) A
23 127 3436G7225 W.F. E0160-1-0H 3436-0436 1M CF24 500 20 127 11VC-A 76 EN3155-003F2222 (a) A
24
25
(a) = BUNDLE D9000095460895 SH = SHIELD
A = ADDED WIRE W.F. = WIRE FERRULE
D = DELETED WIRE
CONF ALL
D. PREPARATION FOR TEST
(1) Task A320-A-34-XX-1620-03001-540A-A - Job Set-up
Job Set-Up Information
Manpower/Resources/Skills
Man-hours 1.00 h
Minimum Number of person 1
Elapsed Time 1.00 h
Referenced Information
Manuals/Drawings References/Sheets
AMM Task 24-38-51-400-001
Procedure
(a) Connect the battery connectors
1 For the job set-up, refer to the installation of the batteries, refer to Ref.
AMM Task 24-38-51-400-001.
2 Remove the blanking caps from the electrical connectors.
3 Make sure that the electrical connectors are clean and in a correct
condition.
4 Connect the connectors to the battery.
5 Turn the knurled nut a quarter turn.
(b) Remove all the warning notices.
E. TEST
CONF 001
(1) Task A320-A-34-XX-1620-01001-390A-A - Test
Job Set-Up Information
Manpower/Resources/Skills
Man-hours 3.00 h
Minimum Number of person 1
Elapsed Time 3.00 h
Referenced Information
Manuals/Drawings References/Sheets
Task 21-26-00-710-001
Task 21-31-34-400-001
Task 21-43-34-400-002
Task 21-61-34-400-001
Task 22-96-00-710-001
AMM Task 22-97-00-710-001
Task 24-22-33-400-002
Task 27-93-34-400-001
Task 27-94-34-400-001
Task 31-36-34-400-001
Task 31-50-00-710-001
Manuals/Drawings References/Sheets
Task 31-50-00-710-004
Task 31-60-00-710-001
Task 33-13-00-710-001
Task 33-14-00-710-001
Task 34-13-00-740-003
Task 34-14-00-740-004
Task 34-36-31-400-001
Task 34-43-34-400-001
Task 34-48-34-400-001
Task 34-52-33-400-001
Task 36-11-34-400-001
Procedure
NOTE: If the aircraft is operated in CAT3 conditions, you must also do the LAND CAT3
capability test, refer to Ref. AMM Task 22-97-00-710-001.
(a) Do the operational test of the instrument and panel integral lighting, refer to Ref.
AMM Task 33-13-00-710-001.
(b) Do the operational test of the lights, refer to Ref. AMM Task 33-14-00-710-001.
(c) Do the operational check of the avionics equipment ventilation-system
via Multipurpose Control and Display Unit (MCDU), refer to Ref. AMM Task
21-26-00-710-001.
(d) Do the operational test of the Automatic Flight System (AFS), refer to Ref. AMM
Task 22-96-00-710-001.
(e) Do the operational test of the Electronic Instrument System (EIS), refer to Ref.
AMM Task 31-60-00-710-001.
(f) Do the operational test of the Electronic Centralized Aircraft Monitoring (ECAM)
control panel, refer to Ref. AMM Task 31-50-00-710-004.
(g) Do the ground scanning of the central warning system, refer to Ref. AMM Task
31-50-00-710-001.
(h) Do the system test of the Air Data Reference (ADR), refer to Ref. AMM Task
34-13-00-740-003.
(i) Do the system test of the Inertial Reference (IR), refer to Ref. AMM Task
34-14-00-740-004.
(j) Do the test after the installation of the aft cargo heat-controller ( FIN 10HC),
refer to Ref. AMM Task 21-43-34-400-002.
(k) Do the test after the installation of the PCs ( FIN 7HH and FIN 27HH), refer to Ref.
AMM Task 21-61-34-400-001.
(l) Do the test after the installation of the CPCs ( FIN 11HL and FIN 12HL), refer to
Ref. AMM Task 21-31-34-400-001.
(m) Do the test after the installation of the BMCs ( FIN 1HA1 and FIN 1HA2), refer to
Ref. AMM Task 36-11-34-400-001.
(n) Do the test after the installation of the EGIUs ( FIN 22XU1 and FIN 22XU2), refer
to Ref. AMM Task 24-22-33-400-002.
(o) Do the test after the installation of the MMRs ( FIN 40RT1 and FIN 40RT2), refer
to Ref. AMM Task 34-36-31-400-001.
(p) Do the test after the installation of the GPWC ( FIN 1WZ), refer to Ref. AMM Task
34-48-34-400-001.
(q) Do the test after the installation of the DMU ( FIN 1TV), refer to Ref. AMM Task
31-36-34-400-001.
(r) Do the test after the installation of the TCAS ( FIN 1SG), refer to Ref. AMM Task
34-43-34-400-001.
(s) Do the test after the installation of the ATC/Mode S Transponders ( FIN 1SH1 and
FIN 1SH2), refer to Ref. AMM Task 34-52-33-400-001.
(t) Do the test after the installation of the ELACs ( FIN 2CE1 and FIN 2CE2), refer to
Ref. AMM Task 27-93-34-400-001.
(u) Do the test after the installation of the SECs ( FIN 1CE1 and FIN 1CE2), refer to
Ref. AMM Task 27-94-34-400-001.
CONF 002
(1) Task A320-A-34-XX-1620-01002-390A-A - Test
Job Set-Up Information
Manpower/Resources/Skills
Man-hours 3.00 h
Minimum Number of person 1
Elapsed Time 3.00 h
Referenced Information
Manuals/Drawings References/Sheets
Task 21-26-00-710-001
Task 22-96-00-710-001
Task 22-97-00-710-001
Task 27-93-34-400-001
Task 27-94-34-400-001
Task 31-36-34-400-001
Task 31-50-00-710-001
Task 31-50-00-710-004
AMM
Task 31-60-00-710-001
Task 33-13-00-710-001
Task 33-14-00-710-001
Task 34-13-00-740-003
Task 34-14-00-740-004
Task 34-43-34-400-001
Task 34-48-34-400-001
Task 34-52-33-400-001
Procedure
NOTE: If the aircraft is operated in CAT3 conditions, you must also do the LAND CAT3
capability test, refer to Ref. AMM Task 22-97-00-710-001.
(a) Do the operational test of the instrument and panel integral lighting, refer to Ref.
AMM Task 33-13-00-710-001.
(b) Do the operational test of the lights, refer to Ref. AMM Task 33-14-00-710-001.
(c) Do the operational check of the avionics equipment ventilation-system via
MCDU, refer to Ref. AMM Task 21-26-00-710-001.
(d) Do the operational test of the AFS, refer to Ref. AMM Task 22-96-00-710-001.
(e) Do the operational test of the EIS, refer to Ref. AMM Task 31-60-00-710-001.
(f) Do the operational test of the ECAM control panel, refer to Ref. AMM Task
31-50-00-710-004.
(g) Do the ground scanning of the central warning system, refer to Ref. AMM Task
31-50-00-710-001.
(h) Do the system test of the ADR, refer to Ref. AMM Task 34-13-00-740-003.
(i) Do the system test of the IR, refer to Ref. AMM Task 34-14-00-740-004.
(j) Do the test after the installation of the GPWC ( FIN 1WZ), refer to Ref. AMM Task
34-48-34-400-001.
(k) Do the test after the installation of the DMU ( FIN 1TV), refer to Ref. AMM Task
31-36-34-400-001.
(l) Do the test after the installation of the TCAS ( FIN 1SG), refer to Ref. AMM Task
34-43-34-400-001.
(m) Do the test after the installation of the ATC/Mode S Transponders ( FIN 1SH1 and
FIN 1SH2), refer to Ref. AMM Task 34-52-33-400-001.
(n) Do the test after the installation of the ELACs ( FIN 2CE1 and FIN 2CE2), refer to
Ref. AMM Task 27-93-34-400-001.
(o) Do the test after the installation of the SECs ( FIN 1CE1 and FIN 1CE2), refer to
Ref. AMM Task 27-94-34-400-001.
CONF 003 004
(1) Task A320-A-34-XX-1620-01003-390A-A - Test
Job Set-Up Information
Manpower/Resources/Skills
Man-hours 3.00 h
Minimum Number of person 1
Elapsed Time 3.00 h
Referenced Information
Manuals/Drawings References/Sheets
Task 21-26-00-710-001
Task 21-31-34-400-001
Task 21-61-34-400-001
Task 22-96-00-710-001
Task 22-97-00-710-001
Task 27-93-34-400-001
Task 27-94-34-400-001
Task 31-36-34-400-001
AMM Task 31-36-34-400-002
Task 31-50-00-710-001
Task 31-50-00-710-004
Task 31-60-00-710-001
Task 33-13-00-710-001
Task 33-14-00-710-001
Task 34-13-00-740-003
Task 34-14-00-740-004
Task 34-36-31-400-001
Manuals/Drawings References/Sheets
Task 34-41-00-740-002
Task 34-43-34-400-001
Task 34-48-34-400-001
Task 34-52-33-400-001
Task 36-11-34-400-001
Task 46-21-34-400-001
Procedure
NOTE: If the aircraft is operated in CAT3 conditions, you must also do the LAND CAT3
capability test, refer to Ref. AMM Task 22-97-00-710-001.
(a) Do the operational test of the instrument and panel integral lighting, refer to Ref.
AMM Task 33-13-00-710-001.
(b) Do the operational test of the lights, refer to Ref. AMM Task 33-14-00-710-001.
(c) Do the operational check of the avionics equipment ventilation-system via
MCDU, refer to Ref. AMM Task 21-26-00-710-001.
(d) Do the operational test of the AFS, refer to Ref. AMM Task 22-96-00-710-001.
(e) Do the operational test of the EIS, refer to Ref. AMM Task 31-60-00-710-001.
(f) Do the operational test of the ECAM control panel, refer to Ref. AMM Task
31-50-00-710-004.
(g) Do the ground scanning of the central warning system, refer to Ref. AMM Task
31-50-00-710-001.
(h) Do the Built-In Test Equipment (BITE) test of the weather radar, refer to Ref. AMM
Task 34-41-00-740-002.
(i) Do the system test of the ADR, refer to Ref. AMM Task 34-13-00-740-003.
(j) Do the system test of the IR, refer to Ref. AMM Task 34-14-00-740-004.
(k) Do the test after the installation of the PCs ( FIN 7HH and FIN 27HH), refer to Ref.
AMM Task 21-61-34-400-001.
(l) Do the test after the installation of the CPCs ( FIN 11HL and FIN 12HL), refer to
Ref. AMM Task 21-31-34-400-001.
(m) Do the test after the installation of the BMCs ( FIN 1HA1 and FIN 1HA2), refer to
Ref. AMM Task 36-11-34-400-001.
(n) Do the test after the installation of the MMRs ( FIN 40RT1 and FIN 40RT2), refer
to Ref. AMM Task 34-36-31-400-001.
(o) Do the test after the installation of the ATSU ( FIN 1TX1), refer to Ref. AMM Task
46-21-34-400-001.
(p) Do the test after the installation of the GPWC ( FIN 1WZ), refer to Ref. AMM Task
34-48-34-400-001.
(q) If removed, do the test after the installation of the DMU ( FIN 1TV), refer to Ref.
AMM Task 31-36-34-400-001.
(r) If removed, do the test after the installation of the FDIMU ( FIN 10TV), refer to
Ref. AMM Task 31-36-34-400-002.
(s) Do the test after the installation of the TCAS ( FIN 1SG), refer to Ref. AMM Task
34-43-34-400-001.
(t) Do the test after the installation of the ATC/Mode S Transponders ( FIN 1SH1 and
FIN 1SH2), refer to Ref. AMM Task 34-52-33-400-001.
(u) Do the test after the installation of the ELACs ( FIN 2CE1 and FIN 2CE2), refer to
Ref. AMM Task 27-93-34-400-001.
(v) Do the test after the installation of the SECs ( FIN 1CE1 and FIN 1CE2), refer to
Ref. AMM Task 27-94-34-400-001.
CONF ALL
F. CLOSE-UP
CONF 001
(1) Task A320-A-34-XX-1620-01001-740A-A - Close-up
Job Set-Up Information
Manpower/Resources/Skills
Man-hours 10.00 h
Minimum Number of person 1
Elapsed Time 10.00 h
Referenced Information
Manuals/Drawings References/Sheets
Task 21-31-34-400-001
Task 21-43-34-400-002
Task 21-61-34-400-001
Task 22-66-34-400-002
Task 22-83-34-400-001
Task 24-22-33-400-002
Task 24-41-00-862-002
Task 25-54-11-400-001
Task 27-93-34-400-001
AMM Task 27-94-34-400-001
Task 31-36-34-400-001
Task 31-53-34-400-001
Task 31-63-34-400-001
Task 34-36-31-400-001
Task 34-43-34-400-001
Task 34-48-34-400-001
Task 34-52-33-400-001
Task 36-11-34-400-001
Task 52-41-00-410-002
Procedure
(a) Make sure that the work areas are clean and clear of tools and other items of
equipment.
(b) De-energize the aircraft electrical circuits, refer to Ref. AMM Task
24-41-00-862-002.
(c) Do the close-up procedure as specified in the installation of the aft cargo heat-
controller ( FIN 10HC), refer to Ref. AMM Task 21-43-34-400-002.
(d) Do the close-up procedure as specified in the installation of the PCs ( FIN 7HH
and FIN 27HH), refer to Ref. AMM Task 21-61-34-400-001.
(e) Do the close-up procedure as specified in the installation of the CPCs ( FIN 11HL
and FIN 12HL), refer to Ref. AMM Task 21-31-34-400-001.
(f) Do the close-up procedure as specified in the installation of the BMCs ( FIN 1HA1
and FIN 1HA2), refer to Ref. AMM Task 36-11-34-400-001.
(g) Do the close-up procedure as specified in the installation of the EGIUs ( FIN
22XU1 and FIN 22XU2), refer to Ref. AMM Task 24-22-33-400-002.
(h) Do the close-up procedure as specified in the installation of the MMRs ( FIN
40RT1 and FIN 40RT2), refer to Ref. AMM Task 34-36-31-400-001.
(i) Do the close-up procedure as specified in the installation of the GPWC ( FIN
1WZ), refer to Ref. AMM Task 34-48-34-400-001.
(j) Do the close-up procedure as specified in the installation of the DMU ( FIN 1TV),
refer to Ref. AMM Task 31-36-34-400-001.
(k) Do the close-up procedure as specified in the installation of the TCAS ( FIN 1SG),
refer to Ref. AMM Task 34-43-34-400-001.
(l) Do the close-up procedure as specified in the installation of the ATC/
Mode S Transponders ( FIN 1SH1 and FIN 1SH2), refer to Ref. AMM Task
34-52-33-400-001.
(m) Do the close-up procedure as specified in the installation of the DMCs ( FIN 1WT2
and FIN 1WT3), refer to Ref. AMM Task 31-63-34-400-001.
(n) Do the close-up procedure as specified in the installation of the FWCs ( FIN
1WW1 and FIN 1WW2), refer to Ref. AMM Task 31-53-34-400-001.
(o) Do the close-up procedure as specified in the installation of the ELACs ( FIN 2CE1
and FIN 2CE2), refer to Ref. AMM Task 27-93-34-400-001.
(p) Do the close-up procedure as specified in the installation of the SECs ( FIN 1CE1
and FIN 1CE2), refer to Ref. AMM Task 27-94-34-400-001.
(q) Do the close-up procedure as specified in the installation of the FACs ( FIN 1CC1
and FIN 1CC2), refer to Ref. AMM Task 22-66-34-400-002.
(r) Do the close-up procedure as specified in the installation of the FMGCs ( FIN
1CA1 and FIN 1CA2), refer to Ref. AMM Task 22-83-34-400-001.
(s) In the FWD cargo compartment, at Frame 24A, install the partition Panel 131CW,
Panel 131DW and Panel 132EW, refer to Ref. AMM Task 25-54-11-400-001.
(t) Close the avionics compartment Door 812, refer to Ref. AMM Task
52-41-00-410-002.
(u) Put the aircraft back to its initial configuration.
CONF 002
(1) Task A320-A-34-XX-1620-01002-740A-A - Close-up
Job Set-Up Information
Manpower/Resources/Skills
Man-hours 8.00 h
Minimum Number of person 1
Elapsed Time 8.00 h
Referenced Information
Manuals/Drawings References/Sheets
AMM Task 22-66-34-400-002
REV 00 Dec 21/15 A320-34-1620
REV 06 Jul 22/19 Page 211
A318/A319/A320/A321
SERVICE BULLETIN
Manuals/Drawings References/Sheets
Task 22-83-34-400-001
Task 24-41-00-862-002
Task 25-54-11-400-001
Task 27-93-34-400-001
Task 27-94-34-400-001
Task 31-36-34-400-001
Task 31-53-34-400-001
Task 31-63-34-400-001
Task 34-43-34-400-001
Task 34-48-34-400-001
Task 34-52-33-400-001
Procedure
(a) Make sure that the work areas are clean and clear of tools and other items of
equipment.
(b) De-energize the aircraft electrical circuits, refer to Ref. AMM Task
24-41-00-862-002.
(c) Do the close-up procedure as specified in the installation of the GPWC ( FIN
1WZ), refer to Ref. AMM Task 34-48-34-400-001.
(d) If removed, do the close-up procedure as specified in the installation of the DMU
( FIN 1TV), refer to Ref. AMM Task 31-36-34-400-001.
(e) Do the close-up procedure as specified in the installation of the TCAS ( FIN 1SG),
refer to Ref. AMM Task 34-43-34-400-001.
(f) Do the close-up procedure as specified in the installation of the ATC/
Mode S Transponders ( FIN 1SH1 and FIN 1SH2), refer to Ref. AMM Task
34-52-33-400-001.
(g) Do the close-up procedure as specified in the installation of the DMCs ( FIN 1WT2
and FIN 1WT3), refer to Ref. AMM Task 31-63-34-400-001.
(h) Do the close-up procedure as specified in the installation of the FWC ( FIN
1WW2), refer to Ref. AMM Task 31-53-34-400-001.
(i) Do the close-up procedure as specified in the installation of the ELACs ( FIN 2CE1
and FIN 2CE2), refer to Ref. AMM Task 27-93-34-400-001.
(j) Do the close-up procedure as specified in the installation of the SECs ( FIN 1CE1
and FIN 1CE2), refer to Ref. AMM Task 27-94-34-400-001.
(k) Do the close-up procedure as specified in the installation of the FACs ( FIN 1CC1
and FIN 1CC2), refer to Ref. AMM Task 22-66-34-400-002.
(l) Do the close-up procedure as specified in the installation of the FMGCs ( FIN
1CA1 and FIN 1CA2), refer to Ref. AMM Task 22-83-34-400-001.
(m) In the FWD cargo compartment, at Frame 24A, install the partition Panel 131CW,
Panel 131DW and Panel 132EW, refer to Ref. AMM Task 25-54-11-400-001.
(n) Put the aircraft back to its initial configuration.
CONF 003 004
(1) Task A320-A-34-XX-1620-01003-740A-A - Close-up
Job Set-Up Information
Manpower/Resources/Skills
Man-hours 10.00 h
Referenced Information
Manuals/Drawings References/Sheets
Task 21-31-34-400-001
Task 21-61-34-400-001
Task 22-66-34-400-002
Task 22-83-34-400-001
Task 24-41-00-862-002
Task 25-54-11-400-001
Task 27-93-34-400-001
Task 27-94-34-400-001
Task 31-36-34-400-001
AMM Task 31-36-34-400-002
Task 31-53-34-400-001
Task 31-63-34-400-001
Task 34-36-31-400-001
Task 34-43-34-400-001
Task 34-48-34-400-001
Task 34-52-33-400-001
Task 36-11-34-400-001
Task 46-21-34-400-001
Task 52-41-00-410-002
Procedure
(a) Make sure that the work areas are clean and clear of tools and other items of
equipment.
(b) De-energize the aircraft electrical circuits, refer to Ref. AMM Task
24-41-00-862-002.
(c) Do the close-up procedure as specified in the installation of the PCs ( FIN 7HH
and FIN 27HH), refer to Ref. AMM Task 21-61-34-400-001.
(d) Do the close-up procedure as specified in the installation of the CPCs ( FIN 11HL
and FIN 12HL), refer to Ref. AMM Task 21-31-34-400-001.
(e) Do the close-up procedure as specified in the installation of the BMCs ( FIN 1HA1
and FIN 1HA2), refer to Ref. AMM Task 36-11-34-400-001.
(f) Do the close-up procedure as specified in the installation of the MMRs ( FIN
40RT1 and FIN 40RT2), refer to Ref. AMM Task 34-36-31-400-001.
(g) Do the close-up procedure as specified in the installation of the ATSU ( FIN
1TX1), refer to Ref. AMM Task 46-21-34-400-001.
(h) Do the close-up procedure as specified in the installation of the GPWC ( FIN
1WZ), refer to Ref. AMM Task 34-48-34-400-001.
(i) If removed, do the close-up procedure as specified in the installation of the DMU
( FIN 1TV), refer to Ref. AMM Task 31-36-34-400-001.
(j) If removed, do the close-up procedure as specified in the installation of the
FDIMU ( FIN 10TV), refer to Ref. AMM Task 31-36-34-400-002.
(k) Do the close-up procedure as specified in the installation of the TCAS ( FIN 1SG),
refer to Ref. AMM Task 34-43-34-400-001.
Procedure
Confirm in the applicable aircraft records that you have completed all the work defined
in this Service Bulletin task set as required.
01
ELAPSED TIME ASSUMPTION SERVICE BULLETIN No A320-34-1620
02
MODIFY THE EQUIPMENT AND THE WIRING IN THE AFT 47.00 1 47.00
ELECTRONICS RACK 80VU
REMOVE THE SHELVES 95VU AND 96VU, FOR ACCESS 5.00 1 5.00
MODIFY THE WIRING IN THE SHELVES 95VU AND 96VU, 2.00 2 1.00
ON BENCH
0 2 4 6 8 10 12 14 16 18 20 22 24 26 56 58 60 62 64 66 70 72
SB ELAPSED TIME
TOTAL MANHOURS 85.00 (HOURS)
SB ELAPSED TIME 73.00
NOTE:
01 THIS CHART IS ONLY A PROPOSAL.
OPERATORS MAY DETERMINE THAT ANOTHER WAY
TO DO THE WORK IS MORE SUITABLE FOR THEM.
MH : MANHOURS
PER : NUMBER OF PERSONS 02 IF A VSB IS INVOLVED, THE ASSOCIATED MANHOURS
ET/S: ELAPSED TIME PER STEP ARE NOT REFLECTED IN THIS GANTT CHART. ICN-A320-A-34XX1620-A-FAPE3-00MEW-A-001-01
MOD No
26100P4406
34-1139
MOD No MOD No
MOD No MOD No 34-1188
CONF 26040P4574 DUAL WXR(*)
26878P4500 21693P1604 27403P5467
34-1467 34-1201
34-1204
34-1482
001 X X X
002 X X
003 X X X X X X
004 X X X X X
NOTE:
"X" IS USED FOR MODIFICATIONS OR SERVICE BULLETINS
EMBODIED BEFORE ACCOMPLISHMENT OF THIS SERVICE BULLETIN
(*) DUAL WXR IS INSTALLED BY MOD No 20046P0030 AND CAN BE REMOVED
BY ANTI MOD No 28373P6056 ICN-A320-A-34XX1620-A-FAPE3-00MEX-A-002-01
NOTE: ISI 00.00.00179 covers all the frequently asked questions about SB Reporting.
It is revised on a regular basis.
If you have difficulties in the accomplishment of this SB please quote below the area(s) and
give a short description of the issue.
Comments :
Operator : Date :
Name/Title
Please return this form to :
AIRBUS
2, ROND POINT EMILE DEWOITINE
31700 BLAGNAC
FRANCE
Or via your Resident Customer Support Office.