JOB CARD MPD-TASK:

IGO - A318/A319/A320/A321 AMM TASK : 12-15-38-613-001-A


12-15-38 PB 301

TITLE:
A/C Reg.:
12-15-38-613-001-A - Fill the Potable Water Tank
** ON A/C ALL
System (Aircraft Electrical Power Available)
CARD: ZONE: INTERVAL:
SKILL: ACCESS: 171AL

MECH. INSP.

** ON A/C ALL

TASK 12-15-38-613-001-A
Fill the Potable Water Tank System (Aircraft Electrical Power Available)

WARNING: DO NOT DO WORK ON THE TOILET WASTE SYSTEM AND THE


POTABLE WATER SYSTEM AT THE SAME TIME. THIS WILL PREVENT
CONTAMINATION OF THE POTABLE WATER SYSTEM. SUCH
CONTAMINATION CAN BE DANGEROUS TO HEALTH.

WARNING: BEFORE YOU DO WORK ON THE POTABLE WATER SYSTEM, CLEAN


YOUR HANDS WITH SOAP AND WATER. THIS WILL PREVENT INFECTION.
(CONTAMINATION FROM TOILET WASTE IS DANGEROUS TO HEALTH).

CAUTION: THE WATER PRESSURE MUST NOT BE MORE THAN 3.45 BARS (50.0 PSI) A
PRESSURE MORE THAN 3.45 BARS (50.0 PSI) CAN CAUSE DAMAGE.

CAUTION: MAKE SURE THAT THE DRAIN VALVES STAY IN THE DRAIN POSITION
AFTER YOU DRAIN THE POTABLE WATER SYSTEM IF:
- THE BLEED AIR SYSTEM IS OFF, AND
- THE OUTSIDE AIR TEMPERATURE IS BELOW 0 DEG.C (32 DEG.F).
THIS WILL PREVENT DAMAGE TO THE POTABLE WATER SYSTEM.

NOTE: To Fill the potable water system, if electrical power is not available (Ref. TASK 12-15-
38-613-002).

1. Reason for the Job


Self Explanatory
2 Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment

REFERENCE QTYDESIGNATION
No specific 1 ACCESS PLATFORM 2M (6 FT)
No specific 1 CART - SERVICING, WATER, POTABLE
No specific 1 WATER SOURCE - GROUND

B. Work Zones and Access Panels

ZONE/ACCESS ZONE DESCRIPTION


171AL

C. Referenced Information
JCP Title: temporary job card package CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 1 of 8
JCP Ref: reference DATABASE REV DATE: May 01/2018
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN COMPLETED TO THE REQUIRED PRINT DATE: Aug 05/2018 17:16
STANDARD AND SUPPORTS THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF RELEASE
TO SERVICE
JOB CARD MPD-TASK:
IGO - A318/A319/A320/A321 AMM TASK : 12-15-38-613-001-A
12-15-38 PB 301

TITLE:
A/C Reg.:
12-15-38-613-001-A - Fill the Potable Water Tank
** ON A/C ALL
System (Aircraft Electrical Power Available)
MECH. INSP.

REFERENCE DESIGNATION

** ON A/C 016-022, 024-100, 103-109, 111-150, 201-201, 203-250, 301-400


(Ref. 12-15-38-613-002-A). Fill the Potable Water Tank System (Aircraft Electrical
Power not Available)

** ON A/C ALL
(Ref. 12-31-38-660-001-A). Cold Weather Maintenance - Water/Waste
(Ref. 12-33-21-618-001-A). Pre-conditioning through the LP Ground Connection
(Ref. 12-33-21-618-001-A- Pre-conditioning through the HP Ground Connection
01).
(Ref. 12-33-21-618-001-A- Pre-conditioning with the APU
02).
(Ref. 24-42-00-861-001-A). Energize the Ground Service Network from the External
Power
(Ref. 24-42-00-862-001-A). De-energize the Ground Service Network Supplied from
the External Power

** ON A/C 016-022, 024-100, 103-109, 111-150, 201-201, 203-250, 301-400


(Ref. 12-15-38-613-002-A). Fill the Potable Water Tank System (Aircraft Electrical
Power not Available) (for corrective action)

** ON A/C ALL

** ON A/C 016-022, 024-100, 103-109, 111-150, 201-201, 203-250, 301-400


Potable Water Service-Panel 2023VU SHEET 1

** ON A/C 401-450
Potable Water Service-Panel 2023VU SHEET 1

JCP Title: temporary job card package CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 2 of 8
JCP Ref: reference DATABASE REV DATE: May 01/2018
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN COMPLETED TO THE REQUIRED PRINT DATE: Aug 05/2018 17:16
STANDARD AND SUPPORTS THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF RELEASE
TO SERVICE
JOB CARD MPD-TASK:
IGO - A318/A319/A320/A321 AMM TASK : 12-15-38-613-001-A
12-15-38 PB 301

TITLE:
A/C Reg.:
12-15-38-613-001-A - Fill the Potable Water Tank
** ON A/C ALL
System (Aircraft Electrical Power Available)
MECH. INSP.

Z171

2023VU SERVICE PANEL

1/2
1/4 3/4
QUANTITY
E F INDICATOR
TANK FULL LIGHT

FILL AND
DRAIN PORT

OVERFLOW VALVE
OPEN LIGHT

FILL AND DRAIN


CONTROL HANDLE

N_MM_121538_3_AAQ0_01_00

Figure 12-15-38-991-00100-00-D / SHEET 1/1 - Potable Water Service-Panel 2023VU


** ON A/C 016-022, 024-100, 103-109, 111-150, 201-201, 203-250, 301-400

JCP Title: temporary job card package CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 3 of 8
JCP Ref: reference DATABASE REV DATE: May 01/2018
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN COMPLETED TO THE REQUIRED PRINT DATE: Aug 05/2018 17:16
STANDARD AND SUPPORTS THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF RELEASE
TO SERVICE
JOB CARD MPD-TASK:
IGO - A318/A319/A320/A321 AMM TASK : 12-15-38-613-001-A
12-15-38 PB 301

TITLE:
A/C Reg.:
12-15-38-613-001-A - Fill the Potable Water Tank
** ON A/C ALL
System (Aircraft Electrical Power Available)
MECH. INSP.

Z171

A
2023VU SERVICE PANEL

FWD DRAIN 1/2


1/4 3/4
VALVE OPEN QUANTITY
E F
INDICATOR
TANK FULL LIGHT

OVERFLOW PORT

FILL AND
DRAIN PORT

CONTROL HANDLE
FILL/OVERFLOW/DRAIN

N_MM_121538_3_AAT0_01_00

Figure 12-15-38-991-00100-00-G / SHEET 1/1 - Potable Water Service-Panel 2023VU


** ON A/C 401-450

JCP Title: temporary job card package CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 4 of 8
JCP Ref: reference DATABASE REV DATE: May 01/2018
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN COMPLETED TO THE REQUIRED PRINT DATE: Aug 05/2018 17:16
STANDARD AND SUPPORTS THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF RELEASE
TO SERVICE
JOB CARD MPD-TASK:
IGO - A318/A319/A320/A321 AMM TASK : 12-15-38-613-001-A
12-15-38 PB 301

TITLE:
A/C Reg.:
12-15-38-613-001-A - Fill the Potable Water Tank
** ON A/C ALL
System (Aircraft Electrical Power Available)
MECH. INSP.

3. Job Set-up
Subtask 12-15-38-861-050-A
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001) .
Subtask 12-15-38-865-053-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:

PANEL DESIGNATION FIN LOCATION

** ON A/C 016-022, 024-100, 103-109, 111-150, 201-201, 203-250, 301-400


2000VU WATER SYSTEM-QANT-IND 1MA B01

** ON A/C 016-022, 024-100, 103-109, 111-150, 201-201, 203-250, 350-350, 401-450


2001VU WATER SYS-DRAIN 1MP B05

** ON A/C 301-349, 351-400


2001VU WATER-SYS-DRAIN 1MP B05

** ON A/C 401-450
2001VU WATER SYS-QUANT-IND 1MA B06

** ON A/C ALL
Subtask 12-15-38-618-050-A
C. Preparation to Fill the Potable Water System
(1) Obey the cold weather maintenance procedure (Ref. AMM TASK 12-31-38-660-
001) .
(2) If the temperature in the aircraft is below 4 DEG.C (39.20 DEG.F) do the pre-
conditioning procedure (Ref. AMM TASK 12-33-21-618-001) .
Subtask 12-15-38-010-050-A
D. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) in position.
(2) Open the access panel 171AL.
(3) Open the POTABLE WATER FILL AND DRAIN port on the service panel.
4. Procedure

** ON A/C 016-022, 024-100, 103-109, 111-150, 201-201, 203-250, 301-400


(Ref. Fig. Potable Water Service-Panel 2023VU SHEET 1)

** ON A/C 401-450
(Ref. Fig. Potable Water Service-Panel 2023VU SHEET 1)

** ON A/C 016-022, 024-100, 103-109, 111-150, 201-201, 203-250, 350-350


Subtask 12-15-38-613-054-A

JCP Title: temporary job card package CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 5 of 8
JCP Ref: reference DATABASE REV DATE: May 01/2018
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN COMPLETED TO THE REQUIRED PRINT DATE: Aug 05/2018 17:16
STANDARD AND SUPPORTS THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF RELEASE
TO SERVICE
JOB CARD MPD-TASK:
IGO - A318/A319/A320/A321 AMM TASK : 12-15-38-613-001-A
12-15-38 PB 301

TITLE:
A/C Reg.:
12-15-38-613-001-A - Fill the Potable Water Tank
** ON A/C ALL
System (Aircraft Electrical Power Available)
MECH. INSP.

A. Add Chlorine to the Potable Water


(1) During the potable water servicing, you can also add chlorine to the potable water.
(2) You can use an in-line water filter cartridge to filter the potable water supplied to
the A/C.

** ON A/C 016-022, 024-100, 103-109, 111-150, 201-201, 203-250, 301-400


Subtask 12-15-38-613-050-E
B. Fill the Potable Water system

CAUTION: BEFORE YOU DO THE SERVICING OF THE POTABLE-WATER


TANK, MAKE SURE THAT THE QUANTITY INDICATION SYSTEM IS
ENERGIZED AND OPERATES CORRECTLY.
IF IT IS NOT, YOU MUST SET THE CONTROL HANDLE (326MM) TO
OPEN THE OVERFLOW VALVE (8MP). IF THIS VALVE IS NOT OPEN,
WATER CAN FLOW INTO THE PASSENGER COMPARTMENT.

(1) If the indication system does not operate satisfactorily, do the servicing without
electrical power (Ref. AMM TASK 12-15-38-613-002) .

NOTE: The "Overflow valve open" light 6MP on the serive panel 2023VU must be
on when the overflow valve 8MP is opened.

NOTE: If the indication system does not operate and electrical power is necessary
on aircraft, you can open the CB 1MA (water system quantity indicator)
(Ref. AMM TASK 12-15-38-613-002) .

(2) Connect the fill hose of the CART - SERVICING, WATER, POTABLE or WATER
SOURCE - GROUND to the POTABLE WATER FILL AND DRAIN port.
(3) On the service panel:
· Turn the FILL/DRAIN handle to the PULL TO FILL position
· Then pull it out to the mechanical stop.

NOTE: The OVERFLOW VALVE OPEN light 6MP comes on.

(4) If the OVERFLOW VALVE OPEN light 6MP does not come on:
· Examine the position of the overflow valve 8MP.

CAUTION: THE WATER PRESSURE MUST NOT BE MORE THAN 3.45 BARS (50.0
PSI) A PRESSURE MORE THAN 3.45 BARS (50.0 PSI) CAN CAUSE
DAMAGE.

(5) Fill the potable water system:

NOTE: The "Overflow valve open" light 6MP on the service panel 2023VU must
be off when the overflow valve 8MP is closed.

(a) Operate the water service vehicle.

JCP Title: temporary job card package CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 6 of 8
JCP Ref: reference DATABASE REV DATE: May 01/2018
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN COMPLETED TO THE REQUIRED PRINT DATE: Aug 05/2018 17:16
STANDARD AND SUPPORTS THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF RELEASE
TO SERVICE
JOB CARD MPD-TASK:
IGO - A318/A319/A320/A321 AMM TASK : 12-15-38-613-001-A
12-15-38 PB 301

TITLE:
A/C Reg.:
12-15-38-613-001-A - Fill the Potable Water Tank
** ON A/C ALL
System (Aircraft Electrical Power Available)
MECH. INSP.

NOTE: If the filling level is to be less than full, push in the Fill/DRAIN handle
and turn it to the NORMAL position. The Quantity Indicator shows the
filling level.

NOTE: The FILL/DRAIN handle will automatically move back to the NORMAL
position when the TANK FULL light comes on. The OVERFLOW
VALVE OPEN light 6MP goes off.

NOTE: If there is too much water in the tank, water will flow from the TANK
OVERFLOW port.

1 If the OVERFLOW VALVE OPEN light 6MP does not go off:


· Examine the overflow valve 8MP.

NOTE: If the tank is overfilled, water will flow from the "TANK
OVERFLOW" port.

2 Stop the water service vehicle.


3 Disconnect the hose from the POTABLE WATER FILL AND DRAIN port.
4 Clean and dry the service panel and the adjacent area.
5 Visually examine the connections for leaks. Leaks are not permitted.
6 Put the cap on the POTABLE WATER FILL AND DRAIN port.

NOTE: If you do the servicing in cold weather conditions, the POTABLE


WATER FILL AND DRAIN port must stay open as long as
possible to drain the residual water from the fill and drain line.

** ON A/C 401-450
Subtask 12-15-38-613-050-H
B. Fill the Potable Water System

CAUTION: THE WATER PRESSURE MUST NOT BE MORE THAN 3.45 BARS (50.0
PSI) A PRESSURE MORE THAN 3.45 BARS (50.0 PSI) CAN CAUSE
DAMAGE.

(1) Connect the fill hose of the CART - SERVICING, WATER, POTABLE or WATER
SOURCE - GROUND to the POTABLE WATER FILL AND DRAIN port.
(2) On the service panel:
· Turn the FILL/OVERFLOW/DRAIN handle to the PULL TO FILL position.
· Then pull it out to the mechanical stop.
(3) Operate the water service vehicle and fill the potable water tank until the quantity
indicator shows the necessary quantity.

NOTE: If the filling level is to be less than full, push in the Fill/OVERFLOW/
DRAIN handle and turn it to the NORMAL position. The Quantity Indicator
shows the filling level.

JCP Title: temporary job card package CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 7 of 8
JCP Ref: reference DATABASE REV DATE: May 01/2018
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN COMPLETED TO THE REQUIRED PRINT DATE: Aug 05/2018 17:16
STANDARD AND SUPPORTS THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF RELEASE
TO SERVICE
JOB CARD MPD-TASK:
IGO - A318/A319/A320/A321 AMM TASK : 12-15-38-613-001-A
12-15-38 PB 301

TITLE:
A/C Reg.:
12-15-38-613-001-A - Fill the Potable Water Tank
** ON A/C ALL
System (Aircraft Electrical Power Available)
MECH. INSP.

(4) Push in the FILL/OVERFLOW/DRAIN handle and turn it to the NORMAL position.

NOTE: The FILL/OVERFLOW/DRAIN handle will automatically go back to the


NORMAL position when the TANK FULL light comes on.

NOTE: If there is too much water in the tank, water will flow from the "POTABLE
WATER OVERFLOW" port.

(a) Stop the water service vehicle.


(b) Disconnect the hose from the POTABLE WATER FILL AND DRAIN port.
(c) Clean and dry the service panel and the adjacent area.
(d) Visually examine the connections for leaks.
1 If there are leaks, repair them.
(e) Put the cap on the POTABLE WATER FILL AND DRAIN port.

NOTE: If you do the servicing in cold weather conditions, the POTABLE


WATER FILL AND DRAIN port must stay open as long as possible.
This is to drain the residual water from the fill and drain line.

** ON A/C ALL
5. Close-up
Subtask 12-15-38-410-050-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access panel 171AL.

NOTE: Make sure that the latches are correctly locked and that the door makes a
continuous surface with the skin of the aircraft.

(3) Remove the access platform(s).


(4) Remove the ground support and maintenance equipment, the special and
standard tools and all other items.
Subtask 12-15-38-862-050-A
B. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001) .
*** END OF CARD ***

JCP Title: temporary job card package CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 8 of 8
JCP Ref: reference DATABASE REV DATE: May 01/2018
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN COMPLETED TO THE REQUIRED PRINT DATE: Aug 05/2018 17:16
STANDARD AND SUPPORTS THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF RELEASE