KTM50S1 50Hz SS304 Merged
KTM50S1 50Hz SS304 Merged
KTM50S1 50Hz SS304 Merged
Client :
Project :
Model : KTM50S1-000 (SS304 material)
Date :
Doc. No. :
Revision No. :
Japan Headquarters :
843-5, Kuji, Takatsu-Ku, Kawasaki-Shi,
Kanagawa, Japan Post-code 213-0032
URL : http://www.nikuni.co.jp
Remarks
Accessory :
Air In-take nozzle.
Please refer to attached recommendation of the air-parameter & guages ranges and other accessories.
Dimension
Note:
1. For KTM50S3
*2 (40)
*3 (125)
*1 : M12
*2 : 40mm
*1 (4-M10) *3 : 150mm
*4 : 38mm
*4 (31)
Coupling Dimension (unit:mm) Applicable motor frame size for Original base-plate.
kw A B C D E F SS kW IEC Frame
5.5,7.5 45 45 90 38 41.3 10 24 5.5 132S
11,15 55 55 120 42 45.3 12 40 7.5 132M
11 160M
15 160L
Sectional Drawing
Material
No. NAME OF PARTS SET MATERIALS
021 Ball Bearing 1 㻌SUJ
022 Ball Bearing 1 㻌SUJ
025 Bracket 1 㻌FC200
027 Bearing Gland 1 㻌㻿㻼㻯
051 Mechanical Seal 1 SiC - SiC
074 Key 1 䚷S45C
081 Slinger 1 㻌NBR
102 Casing 1 㻌㻿㻯㻿㻝㻟
103 Cover 1 㻌㻿㻯㻿㻝㻟
107 Impeller 1 㻌SUS304
108 Shaft 1 㻌SUS304
113, 114 Key, washer & nut 1 㻌SUS304
116 Impeller Key 1 㻌㻿㼁㻿㻟㻝㻢
123 Cover O-Ring 1 㻌㻼㼀㻲㻱
Model KTM50S1
10
NPSHreq.(m)
8
6 NPSH
4
2
0
0 50 100 150 200 250 300
120 60
100 50
Total Head
80 40
Effect
Total Head(m)
Effect(%)
60 30
40 20
20 10
0 0
10.0 0 50 100 150 200 250 300
8.0
Output(kW)
6.0 Output
4.0
2.0
0.0
0 50 100 150 200 250 300
Capacity(L/min)
NIKUNI Co.,Ltd.
Accessories
L1
KTM25 (F)(N)(D) R 3/8B 121 97 167 R 1/4B
B
R 1/4B
L1
Applicable Model
(Large-scaled Type) Dia. (E) Length (L1) Length (L2) Length (L) Dia. (D)
1) Loosen the nuts of the lower pipe joint to allow a nipple to freely move.
2) Mark the pipe bending direction on the pipe surface Noted :
between the upper and lower pipe joints. Fitting connections &
3) Wind a sealing tape around the lower pipe joint’s nipple of the
Air Flow meter should be
suction nozzle, insert it into the nozzle junction of the pump,
and turn the nipple to firmly fix it. prepared by purchaser
4) Turn the pipe to align the mark on the pipe surface so that the
bend nose (gas discharge port) of the pipe will be directed to
the center of the impeller.
5) Tighten the nuts of the lower pipe joint firmly. Air In-iake Nozzle will be
Make sure that the suction nozzle is not manually rotated. attached to every pump
6) Rotate the motor manually (rotate the shaft end of the motor
with a screwdriver) to make sure that the pipe nose of the
nozzle is not interfering with the impeller.
The KTM Series pump user manual must be fully read and understood before operating the pump.
Failure to do so may result in death, serious injury, or property damage. This page is intended for a
basic understanding of the KTM startup operation and is not a substitute for the user manual.
&RDJXODQW)ORFFXODQWSURFHVV
Air
Pressurized Water
To Flotation Tank
KTM
KTM
To KTM
.DU\X7XUER0L[HU
( A)
KTM50S(F)1,S(F)2,S(F)3 300 850 60
KTM65S(F)2 450 900 140
KTM80S(F) 450 900 140
Pressurized Water Outlet