General Tool Specifications US Units SI Units Sensor Specifications (continuation) US Units SI Units
Nominal Tool OD 9-1/2 in. 241 mm Attenuation
Hole Size Range 12-1/4 in. to 26 in. 311 mm to 669 mm Range 0.1–500 ohm-m
Length total (A) 30.2 ft 9.2 m ±1.75% (0.1–25 ohm-m)
Accuracy
Length OTK Sensor Sub (B) 18.1 ft 5.5 m ±0.85 mmho/m (>25 ohm-m)
Length BCPM (C) 12.1 ft 3.7 m 8 in. (20 cm) for 90% response in
Vertical Resolution
Stop Sub (D) 2–3 ft 0.6–0.9 m conductive beds
Weight (including Stop Sub) 6,500 lb 2,955 kg 400 kHz Resistivity
Primary Power Source Drilling fluid driven Turbine Phase Difference
Tool Connections Top/Bottom 7-5/8-in. API box / 7-5/8-in. API pin Range 0.1–1,000 ohm-m
±0.85% (0.1–25 ohm-m)
Accuracy
±0.8 mmho/m (>25 ohm-m)
Operating Specifications and Limits US Units SI Units Attenuation
Flow Rate gpm lpm Range 0.1–200 ohm-m
Low Flow 430 (515)–755 1,630 (1,955)–2,860 ±4% (0.1–10 ohm-m)
Accuracy
Normal Flow 605 (725)–1,090 2,290 (2,750)–4,130 ±4.0 mmho/m (>10 ohm-m)
Moderate High Flow 805 (965)–1,480 3,050 (3,660)–5,600 12 in. (30 cm) for 90% response in
Vertical Resolution
High Flow 865 (1,040)–1,600 3,280 (3,955)–6,050 conductive beds
()—minimum flow rate for Downlink Operation Azimuthal Gamma Ray
Maximum WOB 100,000 lb 450 kN Sensor Type Scintillation (x2)
Maximum Tool Rotation 300 rpm Measurement API GR
Maximum Drilling Torque (at the Bit) 50,000 ft-lb 68 kNm Range 0–500 API
Maximum Torque to Failure 90,000 ft-lb 122 kNm ±2.5 API@100 API and
Accuracy
Maximum Overpull to Failure without ROP=60 ft/hr (18.3 m/hr)
854,000 lb 3,800 kN Vertical Resolution 6 in. 15.3 cm
Rotation
Maximum Tensile Load 1,528,000 lb 6,800 kN Directional
Maximum Operating Temperature 347°F 175°C Tri-axial Accelerometer
Sensor Type
Minimum Operating Temperature -4°F -20°C Tri-axial Flux Gate
Maximum Hydrostatic Pressure 25,000 psi 1,725 bar MTF/GTF switching Operator selectable (default: 3°)
Maximum Bit Pressure Drop No Limitation Measurement Range Resolution Accuracy1
1% max. volume, acc. to API 13B Inclination 0°–180° 0.09° ±0.1°
Sand Content Azimith2,3 0°–360° 0.35° ±1.0°
(<0.5% recommended)
40 ppb = 114 kg/m³ (Any pumping of LCM Toolface
Maximum LCM must be carried out according to Baker Hughes Magnetic2 TF 0°–360° 1.4° ±1.5°
procedures) Gravity3 TF 0°–360° 1.4° ±1.5°
Max DLS for Tool Passage for AutoTrak Total Magnetic Field 0–100,000 nT 35 ±100
With Rotation 6.5°/100 ft 6.5°/30 m Dip Angle2 -90°–90° 0.04° ±0.2°
Without Rotation 13°/100 ft 13°/30 m Annular Pressure
Max DLS for tool passage should only be used as a guide. Actual limits may vary Range 0–25,000 psi 0–1,725 bar
depending on BHA configuration. Please contact Baker Hughes representative for Resolution 5 psi 0,35 bar
specific applications. Accuracy ±0.25% of full scale
±80% Maximum deviation from mean rpm Vibration
(e.g. 100 rpm: rpm Range=20–180), Acceleration Range 0–15 g
Maximum rpm Variation limited by max tool rotation specification, Frequency Range 0–82 Hz
(from recorded memory or as flagged by
Real time log option Lateral and Axial vibration; transmitted as
corresponding real-time severity level)
severity level (scaled to g-RMS)
Refer to Supplemental Technical
Post Run/Memory log options Average and maximum lateral and axial
Maximum Axial and Lateral Vibration Specification document
vibration in g-RMS and as severity level
TDS-20-60-0000-00
Rotation and Stick-Slip
Rotation Speed 0–±1,000 rpm (±1% Accuracy)
Sensor Specifications US Units SI Units Downhole rpm, stick-slip transmitted as
Real time log options
Multiple Propagation Resistivity—MPR™ severity level
2 MHz Resistivity Min., Max., and average rpm, stick-slip
Post Run/Memory log options
and backward rotation severity
Phase Difference
Range 0.1–3,000 ohm-m 1 All Sensor accuracies are 2 Sigma confidence
±0.85% (0.1–50 ohm-m) 2 For a typical magnetic field value at 30° latitude
Accuracy 3 Accuracy applies to inclinations greater than 5.0°
±0.4 mmho/m (>50 ohm-m)
Drilling & Evaluation Although the information contained herein is believed to be accurate, no other representations are made concerning the information. Under no circumstances shall Baker Hughes be liable for any incorrect or incomplete
2001 Rankin Road information. All technical specifications and commercial information concerning the product and/or services described herein may be changed at any time without further notice. Refer to Supplemental Technical Specifications
Houston, Texas 77073 (TDS-20-60-0000-00) for further environmental specific specifications and information on the application, operation, and handling of Baker Hughes tools. Technical Data Summaries are controlled documents and can only be
Phone: +1 713-625-4200 released through the Documentation & Records Management System(s) Group.
www.bakerhughes.com OTK-70-01-002