DBM Sieve

The document outlines the procedure for conducting a sieve analysis of aggregate to determine particle size distribution according to Indian Standard IS: 2386 (Part I) – 1963 (RA 2016). It provides details on the sample being tested such as size and weight, sieve sizes to be used, and measurements to be recorded including weight retained and cumulative percentages. The analysis is to be performed using an oven, balance, and set of sieves, with observations recorded on a standard form.

Uploaded by

imran khan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
74 views1 page

DBM Sieve

The document outlines the procedure for conducting a sieve analysis of aggregate to determine particle size distribution according to Indian Standard IS: 2386 (Part I) – 1963 (RA 2016). It provides details on the sample being tested such as size and weight, sieve sizes to be used, and measurements to be recorded including weight retained and cumulative percentages. The analysis is to be performed using an oven, balance, and set of sieves, with observations recorded on a standard form.

Uploaded by

imran khan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 1

FORMAT NO. : BIPL/QSFM/5.4.

7/39A
SIEVE ANALYSIS OF AGGREGATE
IS: 2386 (Part I) – 1963 (RA 2016)

SRAF No. & Date Date Of Test From To


Max. Size of Material Present in
Sample I/M
Substantial Quantity in mm
Max. Individual Particle Size
Visual Classification
Present in mm
Wt. Of Soil Sample Taken For
Sample Type □ Oven Dried □ Air Dried Analysis -gms
Max. Size Present in Substantial Quantity in mm 63 50 40/31.5 25 20/16 12.5 10 6.3 4.75 2.36

Mass to be taken for test in Kg. → 50 35 15 5 2 1 0.5 0.2 0.2 0.1

Accuracy of Balance required 0.1 % of the weight of test sample

Observations :
Sieve Size Wt. Retained Cumulative
% Retained % Passing
mm gms % Retained
45
37.5
26.5
19
13.2
4.75
2.36
0.300
0.075
Equipments Used :
Oven Balance Sieve

ANALYST LAB IN CHARGE