Beverage Cooler: Experiment #9
Beverage Cooler: Experiment #9
PARTICIPANTS:
EXPERIMENT #9
BEVERAGE COOLER
SUBMITTED ON: 11/01/07
Introduction:
The cabinet refrigerator used in restaurant, supermarket and many places for fresh
food, desserts, salad etc. there are two magnetic gaskets door. Widths of the door are 30 to
85. Also height of the cabinet from 5 5 to 6 5. Size of the refrigerator range from 20 cu/ft to
100 cu/ft. the temperature minimum 35 F and maximum 45 F. also humidity 80%
necessary.
MACHANICAL SEQUENCE OF OPERATION
Interoir Rear:
The electrical components are cabinet light, evaporator fan motor, condenser fan motor,
CSIR type compressor, external overload switch; temperature control normally closed two
light switch, two mullion heaters, perimeter heater, and current relay
When the cooling cabinet is turned on, current will flow from the source to the two
mullion heaters and back to the power source through the neutral line. Current will also
flow from the live line to the perimeter heater, to the neutral line and back to the power
source. If cabinet doors are closed, the cabinet light will be off because the current can not
flow throw the light switches that are kept open by the doors. If the cabinet doors are open
then the light will be on because current will flow through the normally closed light
switches to the light bulb and to the neutral line. Current will also flow from the live line to
the evaporator fan motor, to the neutral line.
Another path that current will flow from the live line to the thermostat and then will
split onto two separate paths. Current will go through the condenser fan motor and into the
neutral line, and the second path will go through the overload to the compressor motor
where the current will flow through run winding, drawing LRA, to the current relay
winding to the neutral line. The current relay coil will close the current relay contact
closing the circuit for the current to flow through the start winding of the compressor, to
the relay switch to the start capacitor and neutral line. After the compressor reach 75% of
its capacity, the current relay switch will open and will disconnect the start winding from
the circuit. In this case, if the thermostat opens, then the both the compressor motor and
the condenser fan motor will stop running. And the set point temperature has been
satisfied.
Observation;
It is a cooling cabinet. Its purpose is to keep food products cool and in high humidity all the
time. This cabinet has the temperature range of 35 F to 45 F. The humidity is kept around
80%.
FLA; the current drawn by an electric motor while operating under a full-load
condition.
LRA; the current an electric motor drawn when it is first turned on. This is normally
five times the full load amperage.
Saturation; when liquid and gas exist at the same time, and any change in temperature,
because more molecules to turn from the gas state into liquid state or versa.
Superheat; the temperature of vapor above its saturation change of state temperature.
Sub-cooling; the temperature of liquid when it is cooled below its condensing
temperature.
Compressor data;
Voltage; 115 v / 60 Hz
Phase ; single
Evaporator data;
Voltage; 115 V / 60 Hz
Phase; single
Start capacitor
Light switches (two of them)
Discussion;
The unit is running properly. It is noticed that after 20 minutes the unit started to
cycle on and off every one or two minutes. This short cycling is due to having no load in
side the cabinet. In additional it is noticed that the data almost perfect according what the
unit suppose to do. The suction temperature and (FLA) were going down as we were going
along super heat was a little bit high but we think it is ok for capillary tube the cabinet
temperature did not look bad at all first 5 min it was 50 F; 10 min it was 41 F; after 30 min
wet down to 35 F. we noticed also head pressure to be a little high than normal it can be
because of iffegular air flow but we think more likely the unit was doing it is perpus ok.
Conclusion;
Unit #$ should be maintained and checked regular intervals. The things that
should be checked and maintained are;
Evaporating temperature 58 14 11 7
(F)
Suction Temperature (F) N/A 71 50 45
L.S superheat Temperature N /A 57 39 36
( F)
Head pressure (psig) 60 140 135 135