2ft Ex Lights

Download as pdf or txt
Download as pdf or txt
You are on page 1of 10

Patent Pending

SafeSite® LED Linear Fixture - UL 844


for Indoor and Outdoor Hazardous Locations
Application
Dialight’s SafeSite® LED linear fixture replaces HID and fluorescent lighting
fixtures in industrial applications and hazardous location applications.

The SafeSite LED Linear fixture’s rugged solid state design makes it highly
® resistant to shock and vibration. Its fully gasketed IP 66 rated enclosure
SafeSite LED Linear Fixture makes it suitable for dust & wet locations, its 1598A rating guarantees added
Low Profile - Class I, Div. 2 / Class II protection from salt water spray. The SafeSite LED Linear’s superior design
allows for wiring and mounting versatility and ease of installation for
many lighting applications.

Mechanical Information
Fixture Weight: 4’ - 10 lbs (4.53 kg)
2’ - 7 lbs (3.18 kg)
Shipping Weight: 4’ - 11 lbs (4.99 kg)
2’ - 8 lbs (3.63 kg)
Mounting: (4) 3/4” NPT openings
Optional swivel bracket - LPXW4
Optional low profile bracket - LPXW4LP
Electrical Specifications
Dimensions in Inches [mm]
Operating Voltage: 100 - 277V AC 50/60Hz
Certifications & Ratings
• Class I Div. 2 Groups A, B, C, D Power Consumption: See ordering information
• Class II Div. 1 Groups E, F, G
• Class II Div. 2 Groups F, G Operating Temp: -40°F to +149°F (-40°C to +65°C)
• Class III Div. 1
• Class III Div. 2 Harmonics: IEC 61000-3-2
• UL 1598/A
• UL 844 Noise Requirements/
• UL 8750 EMC: FCC Title 47, Subpart B, Section 15, class
A device. RF Immunity; 10V/m,
• CSA C22.2 No.137 80MHz-1GHz
• CSA C22.2 No.250
• IP 66 (pending) Surge Protection EN 61000-4-5
• NEMA 4X (pending) 4 kV line to line
4 kV line to ground
Features & Benefits
• 5 year full performance warranty THD: < 20%
• L70 rated for >100,000 hours @ 25°C
• DLC Listed (80 CRI CW & NW models only) Power Factor: > 0.9
• Low profile housing for limited space applications Construction
• Dual NPT entries for in / out wiring
• Thru wiring capability Body: Powder coated aluminum
• Instant on/off operation
• Resistant to water, salt, dust & vibration Lens: Polycarbonate
• Resistant up to 20 PSI of hose directed water
• Universal input (100-277V AC), 50/60Hz Photometric Information
• Mercury free
• Temperature compensation technology for longer life CRI: 75, 80
• Factory sealed
• Integrated wiring box CCT: 5000K (cool white)
4000K (neutral white)
Light Distribution IES Files: Available upon request
All values typical unless otherwise stated
All lumen values are typical (tolerance +/- 10%)

Temperature Ratings
Ambient Temperature Range Ambient Temperature Range
T4A Temperature Code T5 Temperature Code

-40°F to +149°F (-40°C to +65°C) -40°F to +113°F (-40°C to +45°C)

Mounting Options
LPXW4LP Side Mount - LPXW4 Top Mount - LPXW4

2
www.dialight.com
SafeSite® LED Linear Fixture
Class I Div. 2 Ordering Information
Part Number1 Length Type4 CRI Voltage Lens6 Initial Fixture Lumens2,3 Watt Lumens Per Watt
Low Profile Models
LPD3C4M2P 4’ Low Profile 75 100 - 277V AC Clear 7,400 66 112
LPD3C4H2D 4’ Low Profile 75 100 - 277V AC Diffused 7,000 66 106
LPD3B4M2P 4' Low Profile 80 100 - 277V AC Clear 6,300 66 95
LPD3B4H2D 4' Low Profile 80 100 - 277V AC Diffused 6,000 66 91
LPD3C4D2P 2’ Low Profile 75 100 - 277V AC Clear 3,700 33 112
LPD3C4B2D 2’ Low Profile 75 100 - 277V AC Diffused 3,500 33 106
LPD3B4D2P 2' Low Profile 80 100 - 277V AC Clear 3,100 33 94
LPD3B4B2D 2' Low Profile 80 100 - 277V AC Diffused 2,900 33 88

Class II Ordering Information


1 Initial Fixture Lumens
Part Number1 Length Type CRI CIID1 CIID2 CIIID1 CIIID2 Voltage Lens Watt
Lumens Per Watt
Low Profile Models
LPF3C4M2P 4' Low Profile 75 E/F/G F/G • • 100 - 277V AC Clear 7,000 66 106
LPF3C4H2D 4' Low Profile 75 E/F/G F/G • • 100 - 277V AC Diffused 6,600 66 100
LPF3B4M2P 4' Low Profile 80 E/F/G F/G • • 100 - 277V AC Clear 6,300 66 95
LPF3B4H2D 4' Low Profile 80 E/F/G F/G • • 100 - 277V AC Diffused 6,000 66 91
LPF3C4D2P 2' Low Profile 75 E/F/G F/G • • 100 - 277V AC Clear 3,500 33 106
LPF3C4B2D 2' Low Profile 75 E/F/G F/G • • 100 - 277V AC Diffused 3,300 33 100
LPF3B4D2P 2' Low Profile 80 E/F/G F/G • • 100 - 277V AC Clear 3,100 33 94
LPF3B4B2D 2' Low Profile 80 E/F/G F/G • • 100 - 277V AC Diffused 2,900 33 88
Notes:
1
Part numbers listed in the above table are cool white. For neutral white models replace the 5th character with N. Ex. LSD3C4MEP becomes LSD3N4MEP
2
450 Lumens in Battery Backup mode
3
All lumen values are typical (tolerance +/- 10%)
4
See application note on page 3 regarding “sustained” and “maintained” battery modes
For Dialight’s complete list of DLC qualified products, please click this link: www.dialight.com/DLC

Low Profile Models - Class I, Div. 2 / Class II


Part Number Material Description Kit Includes
Class I, Div. 2 / Class II - Low Profile Models

316 Mounting bracket Mounting bracket


LPXW4
Stainless Steel Can be angled at 0°, 30°, 45°, 60° & 90° Mounting hardware

316 Low profile mounting bracket Mounting bracket


LPXW4LP
Stainless Steel Can be angled at 0° and 15° Mounting hardware

304 2 Brackets
LTXENDCAPKIT Chain mount and secondary retention bracket
Stainless Steel Mounting hardware

2 brackets
304
LTXSAFEKIT Safety Cable Kit for secondary retention 2 53” Safety cables
Stainless Steel
Mounting hardware

www.dialight.com 3
Application
The first of its kind, Dialight’s SafeSite® LED linear fixture replaces HID and
fluorescent lighting fixtures in industrial applications and hazardous
location applications.

The SafeSite LED Linear fixture’s rugged solid state design makes it highly
resistant to shock and vibration. Its fully gasketed IP 66 rated enclosure
SafeSite® LED Linear Fixture makes it suitable for dust & wet locations, its 1598A rating guarantees added
protection from salt water spray. The SafeSite LED Linear’s superior design
Top Conduit Mount- Class I, Div. 2 / Class II allows for mounting versatility and ease of installation for many lighting
applications.

Mechanical Information
Fixture Weight: 4’ - 11 lbs (4.99 kg)
2’ - 10 lbs (4.53 kg)
Shipping Weight: 4’ -13 lbs (5.90 kg)
2’ - 12 lbs (5.44 kg)
Mounting: (3) 3/4” NPT openings
Optional swivel bracket - LTXW4
Optional low profile bracket - LTXW4LP

Bracket not included


Electrical Specifications
Dimensions in Inches [mm] Operating Voltage: 100 - 277V AC 50/60Hz
Certifications & Ratings
• Class I Div. 2 Groups A, B, C, D Power Consumption: See ordering information
• Class II Div. 1 Groups E, F, G Operating Temp: -40°F to +149°F (-40°C to +65°C)
• Class II Div. 2 Groups F, G
• Class III Div. 1 Harmonics: IEC 61000-3-2
• Class III Div. 2
• UL 1598/A Noise Requirements/
• UL 844 EMC: FCC Title 47, Subpart B, Section 15, class
A device. RF Immunity; 10V/m,
• UL 8750 80MHz-1GHz
• CSA C22.2 No.137
• CSA C22.2 No.250 Surge Protection EN 61000-4-5
• IP 66 4 kV line to line
• NEMA 4X 4 kV line to ground

Features & Benefits THD: < 20%


• 5 year full performance warranty Power Factor: > 0.9
• L70 rated for >100,000 hours @ 25°C
• DLC Listed (80 CRI CW & NW models only) Construction
• Instant on/off operation
• Resistant to water, salt, dust & vibration Body: Powder coated aluminum
• Vibration tested to UL 844 for 35 hours @ 2,000 CPM
• Resistant up to 20 PSI of hose directed water Lens: Polycarbonate
• Universal input (100-277V AC), 50/60Hz Photometric Information
• Mercury free
• Temperature compensation technology for longer life CRI: 75,80
• Factory sealed
• Integrated wiring box CCT: 5000K (cool white)
4000K (neutral white)
Light Distribution IES Files: Available upon request
All values typical unless otherwise stated
All lumen values are typical (tolerance +/- 10%)

Temperature Ratings
Ambient Temperature Range Ambient Temperature Range
T4A Temperature Code T5 Temperature Code

-40°F to +149°F (-40°C to +65°C) -40°F to +113°F (-40°C to +45°C)

Mounting Options
Conduit Top Mount Conduit Side Mount LTXW4 LTXW4LP

4 www.dialight.com
SafeSite® LED Linear Fixture
Class I Div. 2 Ordering Information
Part Number1
Length Type 5
CRI Voltage Lens6 Initial Fixture Lumens2,3,4 Watt Lumens Per Watt
Top Conduit Models
LTD3C4M2P 4’ Top Conduit 75 100 - 277V AC Clear 7,400 66 112
LTD3C4H2D 4’ Top Conduit 75 100 - 277V AC Diffused 7,000 66 106
LTD3B4M2P 4' Top Conduit 80 100 - 277V AC Clear 6,300 66 95
LTD3B4H2D 4' Top Conduit 80 100 - 277V AC Diffused 6,000 66 91
LTD3C4D2P 2’ Top Conduit 75 100 - 277V AC Clear 3,700 33 112
LTD3C4B2D 2’ Top Conduit 75 100 - 277V AC Diffused 3,500 33 106
LTD3B4D2P 2' Top Conduit 80 100 - 277V AC Clear 3,100 33 94
LTD3B4B2D 2' Top Conduit 80 100 - 277V AC Diffused 2,900 33 88

Class II Ordering Information


1 Initial Fixture Lumens
Part Number1 Length Type CRI CIID1 CIID2 CIIID1 CIIID2 Voltage Lens Watt
Lumens Per Watt
Top Conduit Models
LTF3C4M2P 4' Top Conduit 75 E/F/G F/G • • 100 - 277V AC Clear 7,000 66 106
LTF3C4H2D 4' Top Conduit 75 E/F/G F/G • • 100 - 277V AC Diffused 6,600 66 100
LTF3B4M2P 4' Top Conduit 80 E/F/G F/G • • 100 - 277V AC Clear 6,300 66 95
LTF3B4H2D 4' Top Conduit 80 E/F/G F/G • • 100 - 277V AC Diffused 6,000 66 91
LTF3C4D2P 2' Top Conduit 75 E/F/G F/G • • 100 - 277V AC Clear 3,500 33 106
LTF3C4B2D 2' Top Conduit 75 E/F/G F/G • • 100 - 277V AC Diffused 3,300 33 100
LTF3B4D2P 2' Top Conduit 80 E/F/G F/G • • 100 - 277V AC Clear 3,100 33 94
LTF3B4B2D 2' Top Conduit 80 E/F/G F/G • • 100 - 277V AC Diffused 2,900 33 88
Notes:
1
Part numbers listed in the above table are cool white. For neutral white models replace the 5th character with N. Ex. LTF3C4D2P becomes LTF3N4D2P
For Dialight’s complete list of DLC qualified products, please click this link: www.dialight.com/DLC

Top Conduit Mount Models - Class I, Div. 2 / Class II


Part Number Material Description Kit Includes
Class I, Div. 2 / Class II - Standard Models

5052 Low profile mounting bracket Mounting bracket


LTXW4LP
Aluminum Can be angled at 0° and 15° Mounting hardware

6061 Mounting bracket Mounting bracket


LTXW4
Aluminum Can be angled at 0°, 30°, 45°, 60° & 90° Mounting hardware

304 2 Brackets
LTXENDCAPKIT Chain mount and secondary retention bracket
Stainless Steel Mounting hardware

2 brackets
304
LTXSAFEKIT Safety Cable Kit for secondary retention 2 53” Safety cables
Stainless Steel
Mounting hardware

Retrofit bracket adapter


6061 2 Bracket adapters
LTXLSXW4 (used to connect LTM model fixtures to an
Aluminum Mounting hardware
existing LSXW4 bracket)

www.dialight.com 5
Application:
Dialight’s SafeSite® LED linear fixture replaces HID and fluorescent lighting
fixtures in industrial and hazardous applications. The SafeSite® LED Linear
fixture’s rugged solid state design makes it highly resistant to shock and
vibration. Its fully gasketed IP 66 rated enclosure makes it suitable for dusty
& wet locations. The SafeSite LED Linear’s superior design allows for
mounting versatility and ease of installation for many lighting applications.
SafeSite® LED Linear Fixture This fixture is offered in sustained and maintained configurations.
Sustained has a single AC input and battery backup mode is entered
Battery Backup - Class I, Div. 2 / Class II upon any loss of power. Fixture cannot be turned off without entering
battery backup mode. Maintained has two AC inputs. The fixture can be
turned on and off via AC-1 and Fixture only enters battery backup mode
when AC-2 is lost or low.

Mechanical Information
Fixture Weight: 18.0 lbs (8.16 kg)
Shipping Weight: 21.0 lbs (9.53 kg)
Mounting: (1) Threaded 3/4” NPT Side
(2) Threaded 3/4” NPT Ends
Electrical specifications:
Operating Voltage: 100-277V AC 50/60 Hz
Power Consumption: 85W
Dimensions in Inches [mm]
Operating Temp: -20°F to +149°F (-20°C to +65°C)
Certifications Battery:
• Class I, Division 2, Groups A, B, C, D 3.6V 10Ah NiMH
• Class II, Division 1, Groups E, F, G Expected Battery Life: 4 years
• Class II, Division 2, Groups F, G
• Class III, Division 1 Battery Duration: >3 hours
• Class III, Division 2 Harmonics: IEC 61000-3-2
• UL1598/A
• UL 844 Noise Requirements/
• UL 924 EMC: FCC Title 47, Subpart B, Section 15, class
• CSA C22.2 #250.0 A device. RF Immunity; 10V/m,
• CSA C22.2 No.137 80MHz-1GHz
• IP 66 Surge Protection EN 61000-4-5
• NEMA 4X 1 kV line to line
2 kV line to ground
-

Features & Benefits


• 5 year full performance warranty (excludng batteries) THD: < 20%
• L70 rated for >100,000 hours @ 25°C Power Factor: > 0.9
• 450 lumens in battery backup mode consistent throughout life of battery
• Low power consumption Construction
• Battery status indication light
• Instant on/off operation Body: Powder Coated Aluminum
• Superior color rendition index compared to HPS, LPS, MV Lens: Polycarbonate
• Mercury free
• Resistant to shock and vibration Photometric Information
• Temperature compensation technology for longer life
CRI: 75

Light Distribution CCT: 5650K (cool white)


IES Files: Available upon request
All values typical unless otherwise state
All lumen values are typical (tolerance +/- 10%)

Temperature Ratings
Ambient Temperature Range Ambient Temperature Range
T4A Temperature Code T5 Temperature Code
-20°F to +149°F (-20°C to +65°C) -20°F to +113°F (-20°C to +45°C)

Mounting Options
In-line Conduit Mount Overhead Conduit Mount LSXW4

6
www.dialight.com
SafeSite® LED Linear Fixture
Class I Div. 2 Ordering Information
Part Number1 Length Type5 Voltage Lens6 Initial Fixture Lumens2,3,4 Watt Lumens Per Watt
Battery Backup Models
LSD3C4MEP 4’ Sustained 100 - 277V AC Clear 7,000 85 85
LSD3C4MNP 4’ Maintained 100 - 277V AC Clear 7,000 85 85

Class II Ordering Information


1 Initial Fixture Lumens
Part Number1 Length Type CIID1 CIID2 CIIID1 CIIID2 Voltage Lens Watt
Lumens Per Watt
Battery Backup Models
LSF3C4MEP 4’ Sustained E/F/G F/G • • 100 - 277V AC Clear 7,000 85 85
LSF3C4MNP 4’ Maintained E/F/G F/G • • 100 - 277V AC Clear 7,000 85 85
Notes:
1
Part numbers listed in the above table are cool white. For neutral white models replace the 5th character with N. Ex. LSF3C4D2P becomes LSF3N4D2P
2
450 Lumens in Battery Backup mode
3
Expect a 10% reduction in Lumens for 80 CRI minimum fixtures
4
All lumen values are typical (tolerance +/- 10%)
5
See application note on page 6 regarding “sustained” and “maintained” battery modes
For Dialight’s complete list of DLC qualified products, please click this link: www.dialight.com/DLC

Battery Back up Models - Class I, Div. 2 / Class II


Part Number Material Description Kit Includes
Battery Back up Models

6061 Mounting bracket Mounting bracket


LSXW4
Aluminum Can be angled at 0°, 30°, 45°, 60° & 90° Mounting hardware

304 2 Mounting brackets


LSXENDCAPKIT Chain mount brackets
Stainless Steel Mounting hardware

2 Eyelets
316
HZXSAFEKIT Safety Cable Kit 2 53” Safety cables
Stainless Steel
Mounting hardware

www.dialight.com 7
Application
The first of its kind, the Dialight SafeSite® LED linear luminaire was
designed specifically to replace HID and fluorescent lighting fixtures in
industrial and hazardous location applications. The SafeSite LED Linear
fixture’s rugged solid state design makes it highly resistant to shock and
vibration , while it’s superior design allows for increased mounting
versatility and ease of installation.

Mechanical Information

SafeSite® LED Linear Fixture Fixture Weight: 4’ - 26.0 lbs (11.79 kg)
2’ - 17.5 lbs (7.94 kg)’
Class I, Div. 1 Shipping Weight: 4’ - 28.0 lbs (12.70 kg)
2’ - 19.5 lbs (8.85 kg)
47.46 Mounting: (1) Threaded 3/4” NPT Side
(1205,4) (2) Threaded 3/4” NPT Ends
Electrical specifications:
Operating Voltage: 100 - 277V AC 50/60Hz or
347 - 480V AC 50/60Hz
Power Consumption: See ordering information
4.25 25.56
(108) (649,1) Operating Temp: -40°F to +149°F (-40°C to +65°C)
Harmonics: IEC 61000-3-2
6.98
(177,4) Noise Requirements/
EMC: FCC Title 47, Subpart B, Section 15, class
A device. RF Immunity; 10V/m,
Dimensions in Inches [mm] 80MHz-1GHz
Surge Protection EN 61000-4-5
Certifications 4 kV line to line
• Class I, Div 1 Groups C, D 4 kV line to ground
• UL 844 THD: < 20%
• UL1598
Power Factor: > 0.9
• CSA 22.2 No.137
• UL 8750 Construction
• ABS Design Assessed: # 12-HS942957-PDA Body: Powder Coated Aluminum
• IP 66
Lens: Glass
• NEMA 4X
Photometric Information
CRI: 75
Light Distribution CCT: 5000K Cool White (100-277V AC)
5650K Cool White (347-480V AC)
IES Files: Available upon request
All values typical unless otherwise state
All lumen values are typical (tolerance +/- 10%)

Temperature Ratings
LSC3C4M3GEX (4ft) LSC3C4D3GEX (2ft)
Ambient Temperature Range Ambient Temperature Range
T4a Temperature Code T5 Temperature Code
-40°F to +149°F (-40°C to +65°C) -40°F to +149°F (-40°C to +65°C)

Mounting Options
Conduit Top Mount Conduit Side Mount LSXW5

8 www.dialight.com
SafeSite® LED Linear Fixture
Class I Div. 1 Ordering Information
1
Part Number Length Voltage Lens Initial Fixture Lumens Watt Lumens Per Watt
Class I, Div 1
LSC3C4M3GEX 4’ 100 - 277V AC Clear 7,000 66 106
LSC3C5M3GEX 4’ 347 - 480V AC Clear 7,250 78 93
LSC3C4D3GEX 2’ 100 - 277V AC Clear 3,500 33 106
LSC3C5D3GEX 2’ 347 - 480V AC Clear 3,600 39 92
Notes:
1
Part numbers listed in the above table are cool white. For neutral white models replace the 5th character with N. Ex. LSC3C4D3GEX becomes LSC3N4D3GEX
For Dialight’s complete list of DLC qualified products, please click this link: www.dialight.com/DLC

Standard Models - Class I, Div 1


Part Number Material Description Kit Includes
Class I, Div 1 Models

6061 Mounting bracket Mounting bracket


LSXW5
Aluminum Can be angled at 0°, 30°, 45°, 60° & 90° Mounting hardware

2 Eyelets
316
HZXSAFEKIT Safety Cable Kit 2 53” Safety cables
Stainless Steel
Mounting hardware

Dialight reserves the right to make changes at any time in order to supply the best product possible. The most current version of this document will always be available at:
www.dialight.com/Assets/Brochures_And_Catalogs/Illumination/MDTFSLINX001.pdf. Warranty Statement: EXCEPT FOR THE WARRANTY EXPRESSLY PROVIDED FOR
[HEREIN/ABOVE/BELOW], DIALIGHT DISCLAIMS ANY AND ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OF MERCHANTABILITY,
FITNESS FOR A PARTICULAR PURPOSE, TITLE, AND NONINFRINGEMENT.

www.dialight.com MDTFSLINX001_L 9
SafeSite® LED Linear Fixture - UL 844
for Indoor and Outdoor Hazardous Locations

You might also like