1. SCOPE ................................................................................................................................. 3
2. TOOLS NEEDED ................................................................................................................ 3
3. WARNINGS ......................................................................................................................... 3
4. PROCEDURE ...................................................................................................................... 3
4.1 BOOT DOWNLOAD....................................................................................................................... 3
4.2 SYSTEM VERSION DOWNLOAD ................................................................................................... 4

AGS20 Software Upgrade

SIAE MICROELETTRONICA Proprietary and Confidential. All rights reserved. The copyright of this document is the
property of SIAE MICROELETTRONICA. No part of this document may be copied, reprinted or reproduced in any material
Page 2 of 4 form, whether wholly or in part, without the written consent of SIAE MICROELETTRONICA. Further, the contents of this
document or the methods or techniques contained therein must not be disclosed to any person.
1. SCOPE

Scope of this document is to provide a procedure that describes, step by step, how to perform
the software upgrade of AGS20 equipment.

2. TOOLS NEEDED

A PC equipped with the SCT or WebLCT Console (WLC) software

Software version folders:

• bin (containing the system version)

• boot_e82115_xxyyzz (containing the boot firmware version xx.yy.zz)

The above mentioned version folders are contained in the distributed N31030-01 XXX.zip file
(where XXX varies depending on the distributed version).

3. WARNINGS

Before proceeding with the upgrade, the running boot version shall be verified against the one
provided. If the running version is lower than the provided one, a boot download must be
performed before upgrading the system version. If the running version is equal to the one
provided, the boot download must not be performed.

During the boot firmware download, the connection to the equipment must not be
interrupted.

4. PROCEDURE

4.1 Boot Download


Follow the steps below to perform the boot software upgrade of AGS20 equipment.
1. Unzip files N31030-01 XXX.zip in a suitable directory of the PC used to perform the
upgrade.
2. Connect to the equipment using the SCT or the WebLCT (login as 'System').
3. Open the Software Download window.
4. Select the file E82115.dwl (boot firmware) from the directory boot_e82115_xxyyzz.
5. Select "Only difference or not present/peripheral" as download mode.

AGS20 Software Upgrade

SIAE MICROELETTRONICA Proprietary and Confidential. All rights reserved. The copyright of this document is the
property of SIAE MICROELETTRONICA. No part of this document may be copied, reprinted or reproduced in any material
Page 3 of 4 form, whether wholly or in part, without the written consent of SIAE MICROELETTRONICA. Further, the contents of this
document or the methods or techniques contained therein must not be disclosed to any person.
6. Start the download and confirm by clicking on the window that pops-up.
7. At the end of the boot firmware download, the equipment Controller will automatically
restart. Wait for the restart to be completed.
4.2 System Version Download
1. Unzip files N31030-01 XXX.zip in a suitable directory of the PC used to perform the
upgrade.
2. Connect to the equipment using the SCT or the WebLCT (login as 'System').
3. Open the Software Download window.
4. Select the file N31030.dwl (system version) from the directory bin.
5. Select "Forced" as download mode.
6. Start the download and confirm by clicking on the window that pops-up.
7. At the end of the system version download, to activate the new system version a bench
switch is required: click on “Bench switch” confirm by clicking on the window that pops-
up. Warning: the bench switch may be traffic affecting, depending on the system
version previously running

AGS20 Software Upgrade

SIAE MICROELETTRONICA Proprietary and Confidential. All rights reserved. The copyright of this document is the
property of SIAE MICROELETTRONICA. No part of this document may be copied, reprinted or reproduced in any material
Page 4 of 4 form, whether wholly or in part, without the written consent of SIAE MICROELETTRONICA. Further, the contents of this
document or the methods or techniques contained therein must not be disclosed to any person.

You might also like