0% found this document useful (0 votes)
3K views2 pages

362

This document summarizes test values and settings for a Bosch diesel fuel injection pump and governor for customer Kirloskar. It includes assembly and customer data, test prerequisites, injection pump settings for start of delivery and basic settings, sliding sleeve travel positions, full-load delivery and speed regulation settings, and idle settings. The settings are categorized and include designation, unit of measurement, set values, and minimum and maximum tolerances.

Uploaded by

Ajay Asodariya
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
3K views2 pages

362

This document summarizes test values and settings for a Bosch diesel fuel injection pump and governor for customer Kirloskar. It includes assembly and customer data, test prerequisites, injection pump settings for start of delivery and basic settings, sliding sleeve travel positions, full-load delivery and speed regulation settings, and idle settings. The settings are categorized and include designation, unit of measurement, set values, and minimum and maximum tolerances.

Uploaded by

Ajay Asodariya
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

BOSCH EP test values diesel fuel-injection equipment Page: 1

Test date 17-09-2019 Time: 07:22:57 PM Job. no.: ____________________


Customer ID No. KOEL
Serial no.: ____________________

ASSEMBLY UND CUSTOMER DATA

ASSEMBLY DATA
Edition 17.01.2012
Combination no. F 002 A0Z 362
Fuel-injection pump
Pump designation PES6A95D320RS3500
EP type number F 002 A10 437
Governor
Controller designation RSV325...750A7C1252R
Controller type number F002A20086
Customer ident number KOEL

CUSTOMER DATA
Customer KIRLOSKAR
Engine 6R1080TAG-154HP

TEST PREREQUISITES
CAT Designation Unit Set value min. max. Actual values OT
Test oil ISO 4113
Inlet line 3.1
Calibrating oil inlet temp. °C 40.0 38.0 42.0
Overflow restrictor (type number) F 002 A10 627
Inlet press. bar 1.5 1.4 1.6
Test nozzle holder assembly 0 681 343 009
Opening pressure bar 173.5 172.0 175.0
Test pressure line 1 680 750 014
Outside diameter mm 6.0
x Inside diameter mm 2.0
x Length mm 600

INJECTION PUMP SETTINGS


START OF DELIVERY
CAT Designation Unit Set value min. max. Actual values OT
D Test pressure bar 26.0 25.0 27.0
D Rack travel mm 19.50 18.00 21.00
S Prestroke (as of BDC) mm 3.20 3.15 3.25
C Prestroke (as of BDC) mm 3.20 3.10 3.30
Cam sequence 1-5-3-6-2-4
Port-closing difference °NW 0-60-120-180
240-300
S Tolerance °NW 0.50
Cylinder 1 °NW 0
Cylinder 5 °NW 60 10 110
Cylinder 3 °NW 120 70 170
Cylinder 6 °NW 180 130 230
Cylinder 2 °NW 240 190 290
Cylinder 4 °NW 300 250 350
C Check tolerance °NW 0.75

BASIC SETTING
CAT Designation Unit Set value min. max. Actual values OT
SETTING
D speed rpm 720 720
D Rack travel mm 13.20 13.15 13.25
S Delivery cm3/1000S. 155.00 154.00 156.00
S Spread cm3/1000S. 3.00
C Spread cm3/1000S. 6.00
D speed rpm 325 325
D Rack travel mm 4.80 4.70 4.90
S Delivery cm3/1000S. 8.00 6.00 10.00
S Spread cm3/1000S. 4.00
C Spread cm3/1000S. 5.50

SETTINGS FOR INJECTION PUMP WITH GOVERNOR


CAT = Category (D = Default, S = Setting value, C = Check value)
OT = Outside Tolerance (X is set)
BOSCH EP test values diesel fuel-injection equipment Page: 2

Customer ID No. KOEL


Combination ID No. F002A0Z362

SLIDING SLEEVE TRAVEL/POSITION


CAT Designation Unit Set value min. max. Actual values OT
GUIDE SLEEVE POSITION
D Control lever position ° -3 -3
D speed rpm 700 700
S Rack travel mm 0.50 0.30 0.70
Governor spring pre-tension click setting x 4.00

FULL-LOAD DELIVERY
CAT Designation Unit Set value min. max. Actual values OT
D speed rpm 720 720
D Aneroid pressure hPa 0 0
S Delivery cm3/1000S. 155.00 154.00 156.00
C Delivery cm3/1000S. 155.00 152.00 158.00
S Spread cm3/1000S. 3.00
C Spread cm3/1000S. 6.00

FULL-LOAD SPEED REGULATION/ASSEMBLY GOVERNOR


CAT Designation Unit Set value min. max. Actual values OT
D Control lever position ° 95.00 91.00 99.00
FULL-LOAD SPEED REGULATION
S Rack travel mm 12.20
S speed rpm 755 752.0 758.0
D Rack travel mm 4.00 4.00
S speed rpm 790 780.0 800.0
D Rack travel mm 0.85 0.30 1.40
S speed rpm 950
D Rack travel mm 4.00 4.00 4.00
S speed rpm 810

IDLE
CAT Designation Unit Set value min. max. Actual values OT
S Control lever position ° 72.00 68.00 76.00
IDLE WITHOUT AUXILIARY SPRING
D speed rpm 325 325
S Rack travel mm 4.30 4.25 4.35
D speed rpm 100 100
S CRT min. mm 19.00
C CRT min. mm 19.00
TESTING
D speed rpm 325 325
S Rack travel mm 4.80 4.70 4.90
D Rack travel mm 2.00 2.00
S speed rpm 370 340.0 400.0

TORQUE CONTROL
CAT Designation Unit Set value min. max. Actual values OT
D speed rpm 720 720
S Rack travel mm 13.20 13.15 13.25
C Rack travel mm 13.20 13.15 13.25

IDLE DELIVERY
CAT Designation Unit Set value min. max. Actual values OT
D speed rpm 325 325
S Delivery cm3/1000S. 8.00 6.00 10.00
C Delivery cm3/1000S. 8.00 4.50 11.50
S Spread cm3/1000S. 4.00
C Spread cm3/1000S. 5.50
CAT = Category (D = Default, S = Setting value, C = Check value)
OT = Outside Tolerance (X is set)