D206D6
D206D6
D206D6
Model: D206D6
Powered by DOOSAN
Generator Specification
AU VE
Star ter motor voltage 24V
RI
BURE
ISO 9001
TA S
BUREAU VERITAS
Certification
182 8
Frequency 60HZ
Engine speed (RPM) 1800
AGG Power gensets are compliant with ISO 9001 and CE standard, which include the
following directives: 100% standby power 46.0
·2006/42/EC Machinery safety. Fuel
·2006/95/EC Low voltage 100% prime power 41.3
·EN 60204-1: 2006+A1: 2009, EN ISO 12100: 2010, EN ISO 13849-1: 2008, EN Consumption
75% prime power 30.3
12601 : 2010 (L/H)
50% prime power 21.0
(1) PRP (Prime Power):
According to ISO8528-1, prime power is the maximum power available during a variable
Standard reference Conditions
power sequence, which may be run for an unlimited number of hours per year, between
Note: Standard reference condition 25℃ (77℉) air inlet temp, 100m(328ft) A.S.L 30%
stated maintenance intervals. The permissible average power output during at 24 hours
relative humidity. Fuel consumption dat with diesel fuel with specific gravity of 0.85 and
period shall not exceed 80% of the prime power. 10% overload available for governing
conforming to BS 2869: 1998, Class A2
purposes only.
480/277 206 165 188 150.4 247.8 Length (L) 2570mm 3900mm
Width (W) 1045mm 1220mm
440/254 206 165 188 150.4 270.3
Height (H) 1710mm 2212mm
380/220 206 165 188 150.4 313.0
Net Weight - -
220/127 206 165 188 150.4 540.6
Fuel Tank (L) - -
208/120 206 165 188 150.4 571.8 Note: This parameters allows for some acceptable deviations.
Your Professional Power Assistant
Injection timing 19°±1˚ BTDC Max. static pressure after radiator 0.125 kPa
Bore 111mm
Number of teeth on flywheel 102 Oil filter Full flow, car tridge type
Oil capacity
-Max. 15.5L
Cooling method Fresh water forced circulation Lub oil pressure Idle speed: Min 100 kPa
Alternator Specification
Emergency voltage curve
+ 1%
Poles 4 408 +380
1%
380
- 1%
Winding Connections (standard) Star-serie 352
Terminals 12 296
IP rating IP23
54 +1%%
+-1150
%
50
- 1%
46
38
30
0 1 2 3 4 5 6 7 8 9 10 11 12
δf%:
%: -10.64 Benchmark phase: A Min. frequency: 44.68Hz Recovery time: 1.
. 95s
Three phase Reliable Single phase
δf%:
%: 7.74 Benchmark phase: A Max. frequency: 53.87Hz Recovery time: 0..54s
Options
· Water Jacket · Winding Temp measuring · Tools with the machine · Low fuel level alarm
Pre-heater Instrument · Extended range fuel tank · Automatic fuel
· Fuel heater · Alternator Pre-heater · Bunded fuel tank feeding system
· PMG · Fuel T-valves
· Anti-damp and anti-corrosion
treatment
· Anti-condensation heater
· Winding and bearing RTD
· Rental type · Oil Pre-heater · Front heat protection · Remote control panel
Canopy · Oil temp sensor · ATS
· Trailer · Synchronizing controller
· Adjustable ear th leakage
relay
Control Panel
Configuration Benefits
Operation conditions
Features
· Operation temp: -20 ˚C to + 70 ˚C
· Storage temp: -30 ˚C to + 80 ˚C
· Operating humidity: 95% w/o condensation
· Vibration: 5-25Hz , ±1.6 mm
5-1 00 Hz , a = 4g
· Shocks: a= 500m/s²
Options
[email protected] | www.aggpower.co.uk
Follow us @facebook.com/aggpowergroup
Follow us @linkedin.com/company/agg-power
Follow us @ AGGPOWER