100% found this document useful (2 votes)
131 views36 pages

Symbology Commented

This document contains reference drawings and notes for a Mexico Area 1 Development Project. It lists two reference drawings - one for item numbering and one for facility functional units. It also contains a single note about minimum design temperature indication. The document provides information about the revision history and approvals for a piping and instrumentation diagram for a wellhead platform.

Uploaded by

Salvador Lopez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (2 votes)
131 views36 pages

Symbology Commented

This document contains reference drawings and notes for a Mexico Area 1 Development Project. It lists two reference drawings - one for item numbering and one for facility functional units. It also contains a single note about minimum design temperature indication. The document provides information about the revision history and approvals for a piping and instrumentation diagram for a wellhead platform.

Uploaded by

Salvador Lopez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 36

REFERENCE DRAWINGS

NUMBER TITLE

20198.COD.GEN.SDS ITEM NUMBERING

06215.DOC.GEN.SDS FACILITY FUNCTIONAL UNITS

NOTES:

1. MINIMUM DESIGN TEMPERATURE INDICATION ONLY IF SIGNIFICANT FOR MATERIAL SELECTION.

EX-DE 01 09/08/19 Issue For HAZOP (IFH) P. Martinez J.Dominguez A.Loza G.Vallerga R.Milani
EX-DE 00 29/05/19 Issue For Comments (IFC) O.Nava J.Dominguez A.Loza G.Vallerga R.Milani
Validity Revision
Status Number Contractor Contractor Contractor Company Company
Date Description
Prepared Verified Approved Checked Approved
Index Revision
Company Logo and Business Name Project Name Company Document ID:
Mexico Area 1 –
Development Project 6006C2DPFM07414
Eni Mexico Job N.
Contractor Logo and Business Name Contractor Document ID:

J. Ray McDermott de México S.A de C.V.


Contractor N. 5000015145-A8156
Facility and Sub Facility Name Scale Sheet of Sheets

MEXICO AREA 1- AMOCA WHP1 n.a. 1/18

Document Title Superseeded N. 6006C2BPFM02135 Sh.01


WELLHEAD PLATFORM
Superseeded by N. CPY
PIPING & INSTRUMENTATION DIAGRAM Plant Area Unit
SYMBOLS n.a. n.a.

This document is property of eni ghana exploration and production ltd. It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent. Software: Autocad File Name: 6006C2DPFM07414_01.dwg
REFERENCE DRAWINGS
LINES
NUMBER TITLE
SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION
FROM/TO UNIT BASKET GAS BAG FILTER SWING OUT FLAME GLYCOL GRAVITY BLADE COFFEE MACHINE COOLING TOWER, SUPERHEATER OR DIAPHRAGM PUMP 20198.COO.GEN.SDS ITEM NUMBERING COMPANY SPECIFICATION
CROSSOVER COOLING WATER
LINES STRAINER BURNER REGENERATOR CHILLER WITH AIR LOCK HUMID TYPE- HEATER
CONDENSER NATURAL DRAFT

PRODUCT INLET RUBBER LINE OR ACTIVE CARBON ROTARY VACUUM BURNER ELECTRIC GLYCOL FIRE BARRIER WASHING MACHINE COOLING TOWER, WASTE HEAT METERING PUMP
FLEXIBLE RECOVERY BASKET FILTER (GENERAL) REGENERATOR DRY TYPE- RECOVERY UNIT
MATERIAL FILTER NATURAL DRAFT NOTES:

1. SYMBOL TO BE APPLIED TO MULTIPHASE PUMP.


PRODUCT OUTLET UNDERGROUND CARTRIDGE FILTER VACUUM HEATING COIL INJECTION PUMP
WATER CHILLER AIR LOCK WITH BIDET
PIPE (GENERAL HORIZONTAL EQUIPMENT WITH SEPARATE PARALLEL BLADES TUBE APPLIED TO
SYMBOL) FILTER EQUIPMENT
Class G AIR CONDENSER

SYMBOL DESCRIPTION SYMBOL DESCRIPTION


SUPPLY LIMIT OPERATING TEMP. °C DESING PRESSURE DUPLEX FILTER ELECTROSTATIC AIR ANDLING AIR LOCK WITH WATER CLOSET VERTICAL
AND OPER/DESIGN PRECIPITATOR UNIT TWO DUCT OPPOSITE BLADES EQUIPMENT M SUBMERSIBLE
TEMPERATURE SYSTEM CENTRIFUGAL
Class K PUMP (EXTERNAL
MAX. DES. TEMP.°C MOTOR)
DES. PRESS. barg SYMBOL DESCRIPTION SYMBOL DESCRIPTION
DRIECO
TIN
OF GENERAL FROM/TO SAND (MULTIMEDIA) FILTER PRESS WATER CHILLER MIXING BOX TOILET SINK CENTRIFUGAL INSTRUMENT AIR BARREL PUMP
FLOW: FILTER WITH AIR COMPRESSOR COMPRESSOR M
A A XXXXXXXXXXX
A=ONE WAYFLOW CONDENSER
B B=FLOW DOUBLE B XXXXXXXXXXX
SENSE

PACKAGE LIMIT HOT INSULATED SAND FILTER BELT TYPE FILTER AIR HANDLING UNIT PRESSURE SHOWER CENTRIFUGAL ROTARY EJECTION PUMP
LINE ALL AIR REDUCING BOX COMPRESSOR COMPRESSOR

LINE CHANGE / COLD INSULATED ACTIVE CARBON SEPARADOR HIGH EFFICIENCY CENTRIFUGAL FAN DRINKING WATER KITCHEN SINK 2 PHASE SCREW HAND PUMP
A00 A00 SPECIF.CHANGE LINE FILTER SCREEN AIR FILTER BOILER CENTRIFUGAL COMPRESSOR
(IN DUCT)
(GENERAL) COMPRESSOR

PRINCIPAL LINE JACKETED LINE COALESCER SLIDE GATE AIR HANDLING ROLL TYPE FILTER AXIAL FAN OR WASH-TUB 3 PHASE LOBE SUBMERSIBLE
GENERAL SYMBOL
(SP. 0.8 mm) UNIT ALL AIR BLOWED (IN DUCT) CENTRIFUGAL COMPRESSOR PUMP
PRE-HEATING COMPRESSOR (SUBMERSED
COIL MOTOR)
M

SECONDARY LINE TRACED LINE BY VESSEL WITH STATIC BEND GRID BAG FILTER MOISTURE DISH WASHER RECIPROCATING SLIDING VANE VACUUM PUMP
(SP. 0.4 mm) EXTERNAL HOT DEMISTER/ SEPARATOR COMPRESSOR COMPRESSOR
FLUID COALESCENCE
SEPARATOR V

FUTURE LINE ELECTRIC TRACED PLATE SCREEN MACERATOR/ ROOF TOP AIR FLAT AIR FILTER HUMIDIFIER 2 STAGE FAN (GENERAL) SLURRY PUMP
(SP. 0.4 mm) LINE COMMINUTOR HANDLING UNIT (INSTALLED EQUIPMENT RECIPROCATING
COMPRESSOR
OUTSIDE DUCT) Class H

SYMBOL DESCRIPTION SYMBOL DESCRIPTION


SLOPED LINE HOT INSULATED RAW GAS FILTER FIRE RESISTANT HUMIDIFIER HEAT EXCHANGER AIR COOLER WITH 3 STAGE AXIAL TURBINE PUMP
INTERNAL HOT (GENERAL) ACTUATED LOCK RECIPROCATING COMPRESSOR
00 % CLASS I AIR (INSTALLED IN
FLUID FILTER DUCT) GATE COMPRESSOR
T

NO POCKET LINE EQUIPMENT FILTER SELFCONTAINED ANTIGREASE DRINKING WATER HEAT EXCHANGER BOX COOLER PYSTON ARCHIMEDEAN OR
INSULATION (GENERAL SYMBOL) AIR HANDLING STERILIZER (GENERAL) SINGLE COIL COMPRESSOR
FILTER FOR VOLUTE SCREW
NO POCKET UNIT SPLIT TYPE KITCHEN HOOD (UV TYPE) PUMP
F MM

INTERSECTING SKID LIMIT NATURAL DRAFT HEAT EXCHANGER ECCENTRIC PUMP


DEMINERALIZATION JACKETED HEAT
LINES EQUIPMENT COIL UNIT
(ONE PASS)
EXCHANGER EQUIPMENT
Class D Class M

SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION


DOUBLE SINGLE SELF CONTAINED FAN-COIL HEATING COIL HEAT EXCHANGER BOX EXCHANGER DIESEL ENGINE GAS TURBINE
SYMBOL EXPANDED DETAIL DESCRIPTION COMPLETION COMPLETION (TWO PASS)
AIR HANDLING
HOOK UP LIMIT WELL HEAD WELL HEAD UNIT
MM MD

LINE TO BE ASSEMBLED LINE TO BE ASSEMBLED


AT PLATFORM (OFF-SHORE) ON SITE (ON-SHORE)

HOT FLUID HEATER COOLING COIL REBOILER KETTLE WATER SPRAY GAS ENGINE HYDRAULIC
EQUIPMENT EQUIPMENT TYPE COOLER TURBINE

Class C Class F M MG

SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION


CYCLONE SCALING DIRECT FIRE FURNACE "PRIMARY AIR" AIR CHILLED FLUID ELECTRIC HEATING REBOILER KETTLE FINNED TUBE TURBO EXPANDER STEAM
WEIGHING HEATER (GENERAL) HANDLING UNIT HEATER COIL TYPE RECIPROCATING
(INCLUDING
MACHINE HEATER SERIES) DRIVER
V
M EXCHANGER

M
VERTICAL BASCULE INDIRECT FIRE WATER TUBES HOT FLUID HEATER TRANSFER GRILL WATER COOLER DESUPERHEATER TURBINE WITH EXPANSION
M WITH EXTERNAL
CENTRIFUGE HEATER BOILER INTERMEDIATE TURBINE
GRILLE BLEEDING

HORIZONTAL SUCTION HOOD CABYN TYPE FIRE TUBES BOILER WINDOW TYPE AIR ELECTRIC HEATER LINEAR SUPPLY BUILT-IN ELECTRIC
DECANTER FURNACE HANDLING UNIT DIFFUSER REBOILER IN EXCHANGER EQUIPMENT
CENTRIFUGE VESSELS/ Class P
COLUMNS

SYMBOL DESCRIPTION SYMBOL DESCRIPTION


JET MIXER, AIR TURBINE CYLINDRICAL DRUM BOILER ELECTRIC ELECTRIC GAS CENTRIFUGAL LOBE PUMP
EXHAUST INLET STEAM HEATER
INJECTOR, VERT-TYPE RADIATOR PUMP
LOUVER WITH AIR HEATER HOT OIL
EJECTOR, FURNACE LOCK
EDUCTOR C

AIR DIFFUSOR REACTION FLARE REFRIGERATING FLUID TYPE SUPPLY LOUVER RECOVERY BOILER ELECTRIC HEATING CENTRIFUGAL ROTARY/GEAR
VENTURI WASHER
FURNACE UNIT SPLIT TYPE RADIATING PANEL WITH AIR LOCK TUBE APPLIED TO PUMP PUMP (Note 1)
EQUIPMENT
C

STATIC MIXER ADJUSTABLE WEIR ELECTRIC BURNING PIT FLUID TYPE INLET AND OUTLET PLATE HEAT COOLING TOWER, M 2 STAGE ROTARY/GEAR
RESISTENCE RADIATOR GRILLE EXCHANGER HUMID TYPE - CENTRIFUGAL PUMP
FURNACE FORCED DRAFT PUMP WITH
INTERMEDIATE
EX-DE 01 09/08/19 Issue For HAZOP (IFH) P. Martinez J.Dominguez A.Loza G.Vallerga R.Milani
COOLING EX-DE 00 29/05/19 Issue For Comments (IFC) O.Nava J.Dominguez A.Loza G.Vallerga R.Milani
Validity Revision
Status Number Contractor Contractor Contractor Company Company
SCREEN NATURAD
LRAUGHT ELECTRIC ARC CHIMNEY REFRIGERATING CENTRIFUGAL FAN AIR LOCK AIR COOLER COOLING TOWER, RECIPROCATING PROPELLER OR Date Description
Approved Checked Approved
Prepared Verified
BURNERVENTURI FURNACE (INSIDE UNIT) PUMP SCREW PUMP Index Revision
UNIT SPLIT TYPE DRY TYPE -
TYPE WITH CONDENSER FORCED DRAFT Company Logo and Business Name Project Name Company Document ID:
A Mexico Area 1 –
Development Project 6006C2DPFM07414
Eni Mexico Job N.

VIBRATING SCREEN HORIZONTAL ELECTRIC VENT AXIAL FAN BACK DRAFT AIR PISTON PUMP SLIDING VANE Contractor Logo and Business Name Contractor Document ID:
AIR COOLER WITH
BLADE INDUCTION (INSIDE UNIT) LOCK PUMP
LOUVRES
FLOCCULATOR FURNACE
J. Ray McDermott de México S.A de C.V.
Contractor N. 5000015145-A8156
Facility and Sub Facility Name Scale Sheet of Sheets

TURBINE MEXICO AREA 1- AMOCA WHP1 n.a. 2/18


AGITATOR / MIXER CHEMICAL
(GENERAL)
FLOCCULATOR DOSING CAN PUMP IS MISSING, ADD IT Document Title Superseeded N. 6006C2BPFM02135 Sh.02
PUMP WELLHEAD PLATFORM
Superseeded by N. CPY
PIPING & INSTRUMENTATION DIAGRAM Plant Area Unit
SYMBOLS n.a. n.a.

This document is property of eni ghana exploration and production ltd. It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent. Software: Autocad File Name: 6006C2DPFM07414_02.dwg
REFERENCE DRAWINGS

NUMBER TITLE

20198.COO.GEN.SDS ITEM NUMBERING COMPANY SPECIFICATION

EX-DE 01 09/08/19 Issue For HAZOP (IFH) P. Martinez J.Dominguez A.Loza G.Vallerga R.Milani
EX-DE 00 29/05/19 Issue For Comments (IFC) O.Nava J.Dominguez A.Loza G.Vallerga R.Milani
Validity Revision
Status Number Contractor Contractor Contractor Company Company
Date Description
Prepared Verified Approved Checked Approved
Index Revision
Company Logo and Business Name Project Name Company Document ID:
Mexico Area 1 –
Development Project 6006C2DPFM07414
Eni Mexico Job N.
Contractor Logo and Business Name Contractor Document ID:

J. Ray McDermott de México S.A de C.V.


Contractor N. 5000015145-A8156
Facility and Sub Facility Name Scale Sheet of Sheets

MEXICO AREA 1- AMOCA WHP1 n.a. 3/18

Document Title Superseeded N. 6006C2BPFM02135 Sh.03


WELLHEAD PLATFORM
Superseeded by N. CPY
PIPING & INSTRUMENTATION DIAGRAM Plant Area Unit
SYMBOLS n.a. n.a.

This document is property of eni ghana exploration and production ltd. It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent. Software: Autocad File Name: 6006C2DPFM07414_03.dwg
REFERENCE DRAWINGS

NUMBER TITLE

2019.COO.GEN.SDS ITEM NUMBERING COMPANY SPECIFICATION

EX-DE 01 09/08/19 Issue For HAZOP (IFH) P. Martinez J.Dominguez A.Loza G.Vallerga R.Milani
EX-DE 00 29/05/19 Issue For Comments (IFC) O.Nava J.Dominguez A.Loza G.Vallerga R.Milani
Validity Revision
Status Number Contractor Contractor Contractor Company Company
Date Description
Prepared Verified Approved Checked Approved
Index Revision
Company Logo and Business Name Project Name Company Document ID:
Mexico Area 1 –
Development Project 6006C2DPFM07414
Eni Mexico Job N.
Contractor Logo and Business Name Contractor Document ID:

J. Ray McDermott de México S.A de C.V.


Contractor N. 5000015145-A8156
Facility and Sub Facility Name Scale Sheet of Sheets

MEXICO AREA 1- AMOCA WHP1 n.a. 4/18

Document Title Superseeded N. 6006C2BPFM02135 Sh.04


WELLHEAD PLATFORM
Superseeded by N. CPY
PIPING & INSTRUMENTATION DIAGRAM Plant Area Unit
SYMBOLS n.a. n.a.

This document is property of eni ghana exploration and production ltd. It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent. Software: Autocad File Name: 6006C2DPFM07414_04.dwg
REFERENCE DRAWINGS

NUMBER TITLE

20198.COO.GEN.SDS ITEM NUMBERING COMPANY SPECIFICATION

EX-DE 01 09/08/19 Issue For HAZOP (IFH) P. Martinez J.Dominguez A.Loza G.Vallerga R.Milani
EX-DE 00 29/05/19 Issue For Comments (IFC) O.Nava J.Dominguez A.Loza G.Vallerga R.Milani
Validity Revision
Status Number Contractor Contractor Contractor Company Company
Date Description
Prepared Verified Approved Checked Approved
Index Revision
Company Logo and Business Name Project Name Company Document ID:
Mexico Area 1 –
Development Project 6006C2DPFM07414
Eni Mexico Job N.
Contractor Logo and Business Name Contractor Document ID:

J. Ray McDermott de México S.A de C.V.


Contractor N. 5000015145-A8156
Facility and Sub Facility Name Scale Sheet of Sheets

MEXICO AREA 1- AMOCA WHP1 n.a. 5/18

Document Title Superseeded N. 6006C2BPFM02135 Sh.05


WELLHEAD PLATFORM
Superseeded by N. CPY
PIPING & INSTRUMENTATION DIAGRAM Plant Area Unit
SYMBOLS n.a. n.a.

This document is property of eni ghana exploration and production ltd. It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent. Software: Autocad File Name: 6006C2DPFM07414_05.dwg
SIGNAL LINES MISCELLANEOUS FLOW INSTRUMENTS RELIEF DEVICES GENERAL INSTRUMENTATION TYPICAL DETAILS REFERENCE DRAWINGS

NUMBER TITLE

20198.COO.GEN.SDS ITEM NUMBERING


SET PRESSURE
AAAAA MAGNETIC 0.0 bar g AAAAA
I/P TRANSDUCER AUXILIARY LOCATION PILOT LIGHT 06215.DOC.GEN.SDS FACILITY FUNCITIONAL UNITS
NNN A NNN A
CONNECT TO PROCESS PSV
NNN A
AAAAA
PROPELLER / TURBINE
PRESSURE RELIEF VALVE
P/I TRANSDUCER INSTRUMENT AIR SUPPLY
PNEUMATIC SIGNAL NNN A WITH TYPICAL LABEL IA

N" A N"
POSITIVE DISPLACEMENT
AAAAA
SET PRESSURE
ELECTRICAL SIGNAL SUM 0.0 bar g AS AIR SUPPLY
NNN A
TARGET PSV
NNN A DIAPHRAGM SEAL
SOFTWARE SERIAL / LINK AAAAA
HIGH ALARM VACUUM RELIEF VALVE
NNN A
ULTRASONIC LOCAL CONTROL
INSTRUMENT CAPILLARY PANEL LOCAL CONTROL PANEL
TUBING 010000JPNNN
AAAAA
HIGH HIGH ALARM
NNN A VARIABLE AREA BURST PRESSURE
0.0 bar g
HYDRAULIC SIGNAL ORIFICES ACTUATORS
AAAAA PSE RELIEF RUPTURE DISC
LOW ALARM VORTEX NNN A FOR PRESSURE
NNN A
ELECTROMAGNETIC OR
SONIC SIGNAL FE
AAAAA CORIOLIS TYPE NNN A
LOW LOW ALARM DIAPHRAGM
NNN A MASS FLOWMETER BURST PRESSURE
CORIOLIS
0.0 bar g ORIFICE PLATE WITH QUICK CHANGE FITTING
PSE RELIEF RUPTURE DISC
AAAAA PITOT FE
NNN A FOR VACUUM DIAPHRAGM (PRESSURE BALANCED)
RATIO FUNCTION NNN A
NNN A

IGNITOR SET PRESSURE ORIFICE PLATE


THERMAL MASS FLOW 0.0 bar g
FO DOUBLE OR SINGLE ACTING CYLINDER
THERMAL PSV NNN A
FG
FLOW SIGHT GLASS NNN A
NNN A
AVERAGING PITOT BUCKLING PIN
RESTRICTION ORIFICE
(ANNUBAR) RELIEF VALVE MOTOR (ELECTRIC)
FE
V-CONE NNN A
SET PRESSURE MANUAL
+0.0 mbar g
-0.0 mbar g VENTURI TUBE
GENERAL INSTRUMENTATION CONTROL VALVES SPRING
PVSV
FE
NNN A
NNN A
PRESSURE AND VACUUM
MEASURED VARIABLE AND FUNCTION CONTROL VALVE WITH
3-WAY GATE VALVE RELIEF VALVE SPRING HAND WHEEL
LOADED V-CONE
AAAAA VACUUM PRESSURE
NNN A

SEQUENCE NUMBER AND SUFFIX


CHOKE VALVE
IDENTIFICATION LETTERS FUNCTIONS SOLENOID VALVES
AAAAA
GENERIC INSTRUMENT FIELD MOUNTED
NNN A
FIRST LETTER SECOND LETTERS
2-WAY VALVE
AAAAA GENERIC INSTRUMENT IN PRIMARY LOCATION
NNN A (CONTROL CENTRE) NORMALLY ACCESSIBLE BY OPERATOR GATE VALVE MEASURED OR READOUT OR OUT FUNCTION MODIFIER
MODIFIER
INITIATING VARIABLE PASSIVE FUNCTION
AAAAA INSTRUMENT OR FUNCTION NORMALLY INACCESSIBLE OR BEHIND
THE PANEL DEVICE ON PRIMARY LOCATION SOLENOID WITH MANUAL RESET
NNN A
(CONTROL CENTRE) BALL VALVE A ANALYSIS ALARM
(REDUCED BORE)
AAAAA GENERIC INSTRUMENT IN AUXILIARY LOCATION (UCP) NORMALLY B BURNER,COMBUSTION,FLAME USER'S CHOICE USER'S CHOICE USER'S CHOICE
NNN A ACCESSIBLE BY OPERATOR 3-WAY VALVE
C CORROSION CONTROL FLOW DIRECTION WHEN
BALL VALVE
AAAAA DE-ENERGISED
INSTRUMENT OR FUNCTION NORMALLY INACCESSIBLE OR BEHIND (FULL BORE)
FB
NNN A THE PANEL DEVICE AUXILIARY LOCATION (UCP) D DENSITY DIFFERENTIAL DETECTOR

E VOLTAGE SENSORY DISCREPANCE


AAAAA
SHARED DISPLAY/SHARED CONTROL GLOBE VALVE (PRIMARY ELEMENT)
NNN A
F FLOW RATE RATIO (FRACTION) 4-WAY VALVE
FLOW DIRECTION WHEN
AAAAA SHARED DISPLAY, SHARED CONTROL PRIMARY LOCATION GAS CONCENTRATION DE-ENERGISED
BUTTERFLY VALVE G GLASS, VIEWING DEVICE
NNN A NORMALLY ACCESSIBLE BY OPERATOR (CONTROL CENTRE) (INCLUDING H2S)

H HAND HIGH
AAAAA SHARED DISPLAY, SHARED CONTROL PRIMARY LOCATION NORMALLY
INACCESSIBLE BY OPERATOR (CONTROL CENTRE). INTERLOCK LOGIC
NNN A DIAPHRAGM VALVE I CURRENT (ELECTRICAL) INDICATE

LSD
AAAAA SHARED DISPLAY/CONTROL IN AUXILIARY LOCATION (UCP) NORMALLY J POWER SCAN
I LSD WITH PNEUMATIC LOGIC
NNN A INACCESSIBLE BY OPERATOR.
PLUG VALVE TIME RATE OF
K TIME, TIME SCHEDULE CONTROL STATION
CHANGE
AAAAA SHARED DISPLAY/CONTROL IN AUXILIARY LOCATION (UCP) NORMALLY PSD
ACCESSIBLE BY OPERATOR L LEVEL LIGHT LOW
NNN A I PSD WITH PNEUMATIC LOGIC
DELUGE VALVE
LOGIC CONTROL IN AUXILIARY LOCATION (UCP) MOISTURE / MOTOR MOMENTARY MIDDLE,
M
I ("I" IS THE CONTROL LOGIC SEQUENCE IN VENDOR UCP AND "IZ" INTERMEDIATE
NNN ESD
IS THE EMERGENCY OR PROCESS SHUTDOWN INTERLOCK
N USER'S CHOICE USER'S CHOICE USER'S CHOICE USER'S CHOICE ESD WITH PNEUMATIC LOGIC
IN VENDOR SHUTDOWN PLC). I
PRESSURE REGULATORS
I LOGIC CONTROL IN PRIMARY LOCATION ORIFICE, RESTRICTION
O
NNN ("I" IS THE CONTROL LOGIC SEQUENCE IN DCS AND "IZ" IS THE
EMERGENCY OR PROCESS SHUTDOWN INTERLOCK IN ESD.
P PRESSURE, VACUUM POINT(TEST) CONNECTION EMERGENCY SHUT-DOWN SYSTEM
AAAAA COMPUTER FUNCTION NORMALLY ACCESSIBLE BY OPERATOR IN TWO WAY FILLED
INTEGRATED,
NNN A PRIMARY LOCATION (CONTROL CENTRE) Q QUANTITY TOTALIZE PARTIAL STROKE TEST ESD
I
EMERGENCY SHUT-DOWN
R RADIATION RECORD
AAAAA COMPUTER FUNCTION NORMALLY INACCESSIBLE
NNN A IN PRIMARY LOCATION (CONTROL CENTRE)
S SPEED, FREQUENCY, SMOKE SAFETY SWITCH PSD
THREE WAY FILLED I
PROCESS SHUT-DOWN
AAAAA COMPUTER FUNCTION NORMALLY INACCESSIBLE T TEMPERATURE TRANSMIT
NNN A IN AUXILIARY LOCATION (UCP) EX-DE 01 09/08/19 Issue For HAZOP (IFH) P. Martinez J.Dominguez A.Loza G.Vallerga R.Milani
EX-DE 00 29/05/19 Issue For Comments (IFC) O.Nava J.Dominguez A.Loza G.Vallerga R.Milani
F&G
LOGIC CONTROL NORMALLY INACCESSIBLE OR BEHIND U MULTIVARIABLE MULTIFUNCTION MULTIFUNCTION MULTIFUNCTION / UCP I Validity Revision
Contractor Contractor Contractor Company Company
Status Number Date Description
I THE PANEL DEVICE IN PRIMARY LOCATION (CONTROL CENTRE) PRESSURE WITH F&G/ESD SYSTEM INTERLOCK Index Revision
Prepared Verified Approved Checked Approved

("I" IS THE CONTROL LOGIC SEQUENCE IN VENDOR UCP AND "IZ" IS THE VIBRATION VALVE, DAMPER, LOUVRE
NNN EXTERNAL TAP V Company Logo and Business Name Project Name Company Document ID:
EMERGENCY OR PROCESS SHUTDOWN INTERLOCK IN MECHANICAL ANALYSIS
Mexico Area 1 –
VENDOR SHUTDOWN PLC). PCS 6006C2DPFM07414
WEIGHT, FORCE I Development Project
DIFFERENTIAL PRESSURE W WELL Eni Mexico
CONTROL SYSTEM INTERLOCK Job N.
LOGIC CONTROL NORMALLY INACCESSIBLE OR BEHIND REDUCING REGULATOR Contractor Logo and Business Name Contractor Document ID:
IZ DANGER, SAFETY, EMERGENCY,
THE PANEL DEVICE IN AUXILIARY LOCATION (UCP) ("I" IS THE LOGIC X X AXIS FAUL / SENSORY PIG UNCLASSIFIED PULSATION
NNN ON-OFF VALVE
SEQUENCE OR IN VENDOR UCP AND "IZ" IS THE EMERGENCY OR LSO J. Ray McDermott de México S.A de C.V.
PROCESS SHUTDOWN IN INTERLOCK VENDOR SHUTDOWN PLC). SELF CONTAINED EVENT,STATE OR I Contractor N. 5000015145-A8156
BACK PRESSURE Y Y AXIS RELAY, COMPUTE, CONVERT LOCAL SHUT-DOWN
PRESENCE, SIREN BEACON Facility and Sub Facility Name Scale Sheet of Sheets
REGULATOR
MEXICO AREA 1- AMOCA WHP1 n.a. 6/18
Z POSITION, DIMENSION Z AXIS POSITION
UCP Document Title Superseeded N. 6006C2BPFM02135 Sh.06
SELF CONTAINED I WELLHEAD PLATFORM
PRESSURE REGULATOR UCP INTERLOCK Superseeded by N. CPY
PIPING & INSTRUMENTATION DIAGRAM Plant Area Unit
SYMBOLS n.a. n.a.

This document is property of eni ghana exploration and production ltd. It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent. Software: Autocad File Name: 6006C2DPFM07414_06.dwg
REFERENCE DRAWINGS
TYPICAL 1
NUMBER TITLE
SDV WITH SPRING RETURN ACTUATOR
20198.COO.GEN.SDS ITEM NUMBERING
EXPANDED DETAILS P&ID REPRESENTATION
06215.DOC.GEN.SDS FACILITY FUNCTIONAL UNITS
NOTE 1
DISCREPANCY RESET/OPEN CLOSE
ZLH ZLL UAD HSO HSC
GENERAL NOTES:
A. VALVE TYPE TO BE IN ACCORDANCE TO PROJECT PIPING CLASS.

IZ ESD

I PCS IZ ESD TYP. 1

SDV NOTES:
LOCAL RESET
1. ALARM RESET FUNCTION FOR HMI PURPOSE ONLY.
SDY SDY HS 2. PARTIAL STROKE TEST DEVICE SHALL BE INTEGRATED WITH ACTUATOR VALVE
A B L IA 3. THE SAME TYPICAL IS VALID FOR FULL BORE VALVE

FB
LOCAL CONTROL PANEL FC

ZSH ZSL

SDV

FB
FC

TYPICAL 2
SDV WITH SPRING RETURN ACTUATOR AND PARTIAL STROKE TESTING

EXPANDED DETAILS P&ID REPRESENTATION

PST PST NOTE 1


RESULT INITIATION DISCREPANCY RESET/OPEN CLOSE
UAQ HSQ ZLH ZLL UAD HSO HSC

IZ ESD

I PCS IZ ESD TYP. 2


AMS

SDV
LOCAL RESET
PARTIAL SDY SDY HS
STROKE IA
TEST A B L
DEVICE
FB
NOTE 2 FC
LOCAL CONTROL PANEL

ZSH ZSL ZT

SDV

FB
FC

TYPICAL 3
ON - OFF VALVE (PCS CONTROL) (NOTE 3)

EXPANDED DETAILS P&ID REPRESENTATION

DISCREPANCY OPEN CLOSE


ZLH ZLL UAD HSO HSC

I PCS

I PCS TYP. 3

UV

UY EX-DE 01 09/08/19 Issue For HAZOP (IFH) P.Martinez J.Dominguez A.Loza G.Vallerga R.Milani
EX-DE 00 29/05/19 Issue For Comments (IFC) O.Nava J.Dominguez A.Loza G.Vallerga R.Milani
IA Validity Revision
Status Number Contractor Contractor Contractor Company Company
Date Description
Prepared Verified Approved Checked Approved
Index Revision
Company Logo and Business Name Project Name Company Document ID:
LOCAL CONTROL PANEL
Mexico Area 1 –
Development Project 6006C2DPFM07414
Eni Mexico Job N.
ZSH ZSL Contractor Logo and Business Name Contractor Document ID:

UV J. Ray McDermott de México S.A de C.V.


Contractor N. 5000015145-A8156
Facility and Sub Facility Name Scale Sheet of Sheets

MEXICO AREA 1- AMOCA WHP1 n.a. 7/18

Document Title Superseeded N. 6006C2BPFM02135 Sh.07


WELLHEAD PLATFORM
Superseeded by N. CPY
PIPING & INSTRUMENTATION DIAGRAM Plant Area Unit
SYMBOLS n.a. n.a.

This document is property of eni ghana exploration and production ltd. It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent. Software: Autocad File Name: 6006C2DPFM07414_07.dwg
TYPICAL 4 REFERENCE DRAWINGS
BDV WITH SINGLE ACTION ACTUATOR
NUMBER TITLE

EXPANDED DETAILS P&ID REPRESENTATION 06215.COO.GEN.SDS FACILITY FUNCTIONAL UNITS

DISCREPANCY
RESET
ZLH ZLL UAD
HSR

GENERAL NOTES:
A. VALVE TYPE TO BE IN ACCORDANCE TO PROJECT PIPING CLASS.

PAL
IZ ESD
DCS ESD TYP. 4
I IZ

PT
BDV NOTES:
1. VOLUME TANK SHALL BE NUMBERED 014600-VA-NNNNN.

//
//
//
BDY BDY

//
A B // // // // // // // // // IA

//
FO
FB

//
LOCAL CONTROL PANEL

//
//
//
//
//
//
//
//
//
//
//
//
ZSH ZSL PI

//
//
PSV

//
NOTE

//
//
//
L

//
//
1

//
//
//
//
BDV

//
//
//
//
//
//
//
//
FO
FB

TYPICAL 5
ELECTRIC MOTOR OPERATED VALVE (HARDWIRED TO PCS)

EXPANDED DETAILS P&ID REPRESENTATION

STOP HSO OPEN OPEN FAILURE ZI


HSZ UAL UAX VALVE
POSITION
CLOSE CLOSE INDICATOR

I PCS

TYP. 5

I PCS

MOV
M

ZSH ZSL

MOV

TYPICAL 6
ELECTRIC MOTOR OPERATED VALVE (FIELDBUS)

EXPANDED DETAILS P&ID REPRESENTATION

STOP OPEN OPEN FAILURE ZI


HSZ HSO UAL UAX VALVE
POSITION
CLOSE CLOSE INDICATOR

I PCS

TYP. 6

I PCS

MOV
M

EX-DE 01 09/08/19 Issue For HAZOP (IFH) P.Martinez J.Dominguez A.Loza G.Vallerga R.Milani
EX-DE 00 29/05/19 Issue For Comments (IFC) O.Nava J.Dominguez A.Loza G.Vallerga R.Milani
Validity Revision
Status Number Contractor Contractor Contractor Company Company
Date Description
Prepared Verified Approved Checked Approved
Index Revision
Company Logo and Business Name Project Name Company Document ID:
Mexico Area 1 –
Development Project 6006C2DPFM07414
ZSH ZSL Eni Mexico Job N.
Contractor Logo and Business Name Contractor Document ID:

MOV J. Ray McDermott de México S.A de C.V.


Contractor N. 5000015145-A8156
M Facility and Sub Facility Name Scale Sheet of Sheets

MEXICO AREA 1- AMOCA WHP1 n.a. 8/18

Document Title Superseeded N. 6006C2BPFM02135 Sh.08


WELLHEAD PLATFORM
Superseeded by N. CPY
PIPING & INSTRUMENTATION DIAGRAM Plant Area Unit
SYMBOLS n.a. n.a.

This document is property of eni ghana exploration and production ltd. It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent. Software: Autocad File Name: 6006C2DPFM07414_08.dwg
TYPICAL 7 REFERENCE DRAWINGS
SDV WITH SPRING RETURN ACTUATOR (UCP CONTROL) NUMBER TITLE

EXPANDED DETAILS P&ID REPRESENTATION 20198.COO.GEN.SDS ITEM NUMBERING

06215.COO.GEN.SDS FACILITY FUNCTIONAL UNITS


NOTE 1
DISCREPANCY RESET/OPEN CLOSE
ZLHU ZLLU UADU HSOU HSCU

GENERAL NOTES:
A. VALVE TYPE TO BE IN ACCORDANCE TO PROJECT PIPING CLASS.

IZ UCP - ESD

I UCP IZ UCP - ESD TYP. 7

SDV NOTES:
LOCAL RESET
1. ALARM RESET FUNCTION FOR HMI PORPUSE ONLY.
SDY SDY HS 2. PARTIAL STROKE TEST DEVICE SHALL BE INTEGRATED WITH ACTUADOR VALVE.
A B L IA 3. THE SAME TYPICAL IS VALID FOR FULL BORE VALVE.

FB
LOCAL CONTROL PANEL FC

ZSH ZSL

SDV

FB
FC

TYPICAL 8
SDV WITH SPRING RETURN ACTUATOR AND PARTIAL STROKE TESTING (UCP CONTROL)

EXPANDED DETAILS P&ID REPRESENTATION

PST PST NOTE 1


RESULT INITIATION DISCREPANCY RESET/OPEN CLOSE
UAQU HSQU ZLHU ZLLU UADU HSOU HSCU

IZ UCP - ESD

UCP UCP - ESD TYP. 8


I IZ

SDV
LOCAL RESET
PARTIAL SDY SDY HS
STROKE IA
A B L
TEST
DEVICE
FB
NOTE 2 FC
LOCAL CONTROL PANEL

ZSH ZSL ZT

SDV

FB
FC

TYPICAL 9
ON - OFF VALVE (UCP CONTROL) (NOTE 3)

EXPANDED DETAILS P&ID REPRESENTATION

DISCREPANCY OPEN CLOSE


ZLHU ZLLU UADU HSOU HSCU

I UCP

I UCP TYP. 9

UV

UY EX-DE 01 09/08/19 Issue For HAZOP (IFH) P.Martinez J.Dominguez A.Loza G.Vallerga R.Milani
IA EX-DE 00 29/05/19 Issue For Comments (IFC) O.Nava J.Dominguez A.Loza G.Vallerga R.Milani
Validity Revision
Status Number Contractor Contractor Contractor Company Company
Date Description
Prepared Verified Approved Checked Approved
Index Revision
LOCAL CONTROL PANEL Company Logo and Business Name Project Name Company Document ID:
Mexico Area 1 –
Development Project 6006C2DPFM07414
Eni Mexico Job N.
ZSH ZSL Contractor Logo and Business Name Contractor Document ID:

UV J. Ray McDermott de México S.A de C.V.


Contractor N. 5000015145-A8156
Facility and Sub Facility Name Scale Sheet of Sheets

MEXICO AREA 1- AMOCA WHP1 n.a. 9/18

Document Title Superseeded N. 6006C2BPFM02135 Sh.09


WELLHEAD PLATFORM
Superseeded by N. CPY
PIPING & INSTRUMENTATION DIAGRAM Plant Area Unit
SYMBOLS n.a. n.a.

This document is property of eni ghana exploration and production ltd. It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent. Software: Autocad File Name: 6006C2DPFM07414_09.dwg
TYPICAL 10 REFERENCE DRAWINGS
BDV WITH SINGLE ACTION ACTUATOR (UCP CONTROL)
NUMBER TITLE

EXPANDED DETAILS P&ID REPRESENTATION 20198.C00.GEN.SDS ITEM NUMBERING

06215.C00.GEN.SDS FACILITY FUNCTIONAL UNITS


DISCREPANCY RESET
ZLH ZLL UAD HSR

GENERAL NOTES:
1. VALVE TYPE TO BE IN ACCORDANCE TO PROJECT PIPING CLASS.

PAL
IZ UCP - ESD
UCP UCP - ESD TYP. 10
I IZ

PT
BDV NOTES:
1. VOLUME TANK SHALL BE NUMBERED 014600-VA-NNNNN
BDY BDY 2. OPENING PERCENTAGE OF CHOKE VALVE CAN BE DEFINED BY PCS.
A B IA 3. ELECTRICAL ACTUATOR.
FO 4. THE ACTUATOR RECEIVE A SIGNAL (HIC) 4-20mA TO MODULATE CONTROLL OF VALUE AND
SIGNAL FEEDBACK 4-20mA.
LOCAL CONTROL PANEL

ZSH ZSL PI
NOTE PSV
L
1
BDV

FO

TYPICAL 11
ELECTRIC MOTOR OPERATED VALVE (UCP CONTROLLED)

EXPANDED DETAILS P&ID REPRESENTATION

HSZ STOP HSO OPEN UAL OPEN UAX FAILURE ZI VALVE


POSITION
CLOSE CLOSE INDICATOR

I UCP

TYP. 11

I UCP

MOV
M

ZSH ZSL

MOV
M

TYPICAL 12
TYPICAL FOR MOTORIZED CHOKE VALVE

EXPANDED DETAILS P&ID REPRESENTATION

HSL LOC/REM HSZ STOP HSO OPEN UAL OPENED UAX FAILURE ZI VALVE
POSITION
CLOSE OPENED INDICATOR

I PCS

I PCS
HSO
(NOTE 2,3,4)
OPEN

HSC HV
M
CLOSE
EX-DE 01 09/08/19 Issue for HAZOP (IFH) P.Martinez J. Dominguez A.Loza G. Vallerga R.Milani
EX-DE 00 29/05/19 Issue for comments (IFC) O.Nava J. Dominguez A.Loza G. Vallerga R.Milani
Validity Revision
Status Number Contractor Contractor Contractor Company Company
HSZ Date Description
Prepared Verified Approved Checked Approved
ZT ZSH ZSL Index Revision

STOP Company Logo and Business Name Project Name Company Document ID:
Mexico Area 1 –
Development Project 6006C2DPFM07414
HV HSL
M Eni Mexico Job N.

LOC/REM Contractor Logo and Business Name Contractor Document ID:

J. Ray McDermott de México S.A de C.V.


Contractor N. 5000015145-A8156
Facility and Sub Facility Name Scale Sheet of Sheets

MEXICO AREA 1- AMOCA WHP1 n.a. 10/18

Document Title Superseeded N. 6006C2BPFM02135 Sh.10


WELLHEAD PLATFORM
Superseeded by N. CPY
PIPING & INSTRUMENTATION DIAGRAM Plant Area Unit
SYMBOLS n.a. n.a.

This document is property of eni ghana exploration and production ltd. It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent. Software: Autocad File Name: 6006C2DPFM07414_10.dwg
REFERENCE DRAWINGS
LEVEL INSTRUMENTATION WITH BRIDLE WITH SB&B (NOTE 1) LEVEL INSTRUMENTATION WITH DB&B (NOTE 1) FLOW ORIFICE WITH DB&B NUMBER TITLE

P&ID REPRESENTATION P&ID REPRESENTATION P&ID REPRESENTATION P&ID REPRESENTATION P&ID REPRESENTATION 20198.COO.GEN.SDS ITEM NUMBERING

06215.COO.GEN.SDS FACILITY FUNCTIONAL UNITS

VESSEL VESSEL
VESSEL VESSEL
GENERAL NOTES:
FT

1. PROVIDE VALVE DRAINS AT THE LINE LOWEST POINTS AND VALVED VENTS AT THE LINE HIGHEST POINTS.
LG LT LT LG LT LT
(NOTE 5) (NOTE 5)
2. CD LINES WHICH ARE CONNECTED TO THE CLOSED DRAIN NETWORK SHALL BE SLOPED, NO POCKET LINES.

3. SY LINES WHICH ARE CONNECTED TO THE OPEN DRAIN NETWORK SHALL BE SLOPED, NO POCKET LINES.

NOTES:

TYPICAL PROCESS CONNECTION (NOTE 3) TYPICAL PROCESS CONNECTION (NOTE 3) TYPICAL PROCESS CONNECTION (NOTE 3) TYPICAL PROCESS CONNECTION (NOTE 3) TYPICAL PROCESS CONNECTION (NOTE 3) 1. DB&B FOR RATING > 300#. SB&B FOR RATING ≤ 300#.

2. IF INSTRUMENT IS USED FOR ESD INSOLATION VALVES SHALL BE CAR SEAL OPEN (CSO).

3. FOR TYPE OF VALVES AND DIAMETER REFER TO PIPING CLASS SPECIFICATION OR VESSEL TRIM.
V V
4. STAND PIPE VENT TO ATMOSPHERE TO BE LOCATED AT SAFE LOCATION.

5. TYPICAL VALID ALSO FOR SINGLE LEVEL GAUGE INSTALLATION.


2" 2" FT
VESSEL VESSEL

1" (NOTE 2) 1"


1" 2" 1" 2"
VESSEL VESSEL INSTRUMENT
PIPING
(NOTE 2) (NOTE 2)
INSTRUMENT

INSTRUMENT
INSTRUMENT

INSTRUMENT

INSTRUMENT

INSTRUMENT
PIPING

PIPING
LT LT
PIPING

PIPING

PIPING

PIPING
LG LT LG LT

2" 2"
1" 1"
1" 1"
(NOTE 2)

2" 2"
FE

D D

FLOW ORIFICE WITH SB&B PRESSURE INSTRUMENT WITH DB&B PRESSURE INSTRUMENT WITH SB&B TEMPERATURE INSTRUMENT ELECTRICALLY TRACED (GENERIC) INSTRUMENT

P&ID REPRESENTATION P&ID REPRESENTATION P&ID REPRESENTATION P&ID REPRESENTATION P&ID REPRESENTATION

PT PT TT
FT

TYPICAL PROCESS CONNECTION (NOTE 3) TYPICAL PROCESS CONNECTION (NOTE 3) TYPICAL PROCESS CONNECTION (NOTE 3) TYPICAL PROCESS CONNECTION (NOTE 3)

TT TW

PT PT
TE
FT
INSTR.

INSTR.
PIPING

PIPING

INSTRUMENT
INSTR.
PIPING (NOTE 2) (NOTE 2)
1-1/2"
(NOTE 2) (NOTE 2) PIPING PIPING
PIPING

PIPING

EX-DE 01 09/08/19 Issue for HAZOP (IFH) P. Martinez J. Dominguez A.Loza G. Vallerga R.Milani
EX-DE 00 29/05/19 Issue for comments (IFC) M Trujillo J. Dominguez A.Loza G. Vallerga R.Milani
Validity Revision
PT PT TT TW Status Number Date Description
Contractor Contractor Contractor Company Company
Prepared Verified Approved Checked Approved
Index Revision
Company Logo and Business Name Project Name Company Document ID:
INSTR.

INSTR.

TE Mexico Area 1 –
Development Project 6006C2DPFM07414
Eni Mexico Job N.
PIPING

PIPING

Contractor Logo and Business Name Contractor Document ID:


FE (NOTE 2) (NOTE 2)
J. Ray McDermott de México S.A de C.V.
INSTR.

VESSEL VESSEL
Contractor N. 5000015145-A8156
2" Facility and Sub Facility Name Scale Sheet of Sheets

n.a. 11/18
PIPING

MEXICO AREA 1- AMOCA WHP1


VESSEL
Document Title Superseeded N. 6006C2BPFM02135 Sh.11
WELLHEAD PLATFORM
Superseeded by N. CPY
PIPING & INSTRUMENTATION DIAGRAM Plant Area Unit
SYMBOLS n.a. n.a.

This document is property of eni ghana exploration and production ltd. It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent. Software: Autocad File Name: 6006C2DPFM07414_11.dwg
REFERENCE DRAWINGS

LEVEL INSTRUMENT (INTERFACE LEVEL TYPE) WITH DB&B LEVEL INSTRUMENT (INTERFACE LEVEL TYPE) WITH DB&B H S SERVICE NUMBER TITLE

20198.COO.GEN.SDS ITEM NUMBERING COMPANY SPECIFICATION


P&ID REPRESENTATION P&ID REPRESENTATION

VESSEL
VESSEL
NOTES:
1. FOR TYPE OF VALVES AND DIAMETER REFER TO PIPING CLASS SPECIFICATION
ALL TRIM NUMERED ACCORDING TO LINE IDENTIFICATION
LG LT LT
(NOTE 3) 2. WHERE BLEEDS ARE COLLECTED SHALL BE SPECIFIED:
FH FOR VENTS COLLECTED TO HIGH PRESSURE FLARE

RJ FOR VENTS COLLECTED TO LOW PRESSURE FLARE

DC FOR DRAINS COLLECTED TO CLOSED DRAIN

DC DC 3. TYPICAL VALID ALSO FOR SINGLE LEVEL GAUGE INSTALLATION

TYPICAL PROCESS CONNECTION (NOTE 1) TYPICAL PROCESS CONNECTION (NOTE 1)

2"
VESSEL
1"
1" 2"
VESSEL

INSTRUMENT
INSTRUMENT

INSTRUMENT

PIPING
LT
PIPING

PIPING

LG LT

2"
1"
1"

2"
INSTR.

INSTR.

INSTR.
PIPING

PIPING

PIPING

DC DC

D D

LEVEL INSTRUMENT (INTERFACE LEVEL TYPE) WITH SB&B

P&ID REPRESENTATION P&ID REPRESENTATION P&ID REPRESENTATION P&ID REPRESENTATION

VESSEL
VESSEL

LG LT LT
(NOTE 3)

DC DC

TYPICAL PROCESS CONNECTION (NOTE 1) TYPICAL PROCESS CONNECTION (NOTE 1)

2"
VESSEL
1"
1" 2"
VESSEL
INSTRUMENT
INSTRUMENT

INSTRUMENT

PIPING

LT
PIPING

PIPING

LG LT

2"
1"
1"

2"
INSTR.

INSTR.

INSTR.

EX-DE 01 09/08/19 Issue for HAZOP (IFH) P.Martinez J. Dominguez A.Loza G. Vallerga R.Milani
EX-DE 00 29/05/19 Issue for comments (IFC) O.Nava J. Dominguez A.Loza G. Vallerga R.Milani
Validity Revision
Status Number Contractor Contractor Contractor Company Company
Date Description
PIPING

PIPING

PIPING

Prepared Verified Approved Checked Approved


Index Revision

2" 2" Company Logo and Business Name Project Name Company Document ID:
DC DC Mexico Area 1 –
Development Project 6006C2DPFM07414
D D Eni Mexico Job N.
Contractor Logo and Business Name Contractor Document ID:

J. Ray McDermott de México S.A de C.V.


Contractor N. 5000015145-A8156
Facility and Sub Facility Name Scale Sheet of Sheets

MEXICO AREA 1- AMOCA WHP1 n.a. 12/18

Document Title Superseeded N. 6006C2BPFM02135 Sh.12


WELLHEAD PLATFORM
Superseeded by N. CPY
PIPING & INSTRUMENTATION DIAGRAM Plant Area Unit
SYMBOLS n.a. n.a.

This document is property of eni ghana exploration and production ltd. It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent. Software: Autocad File Name: 6006C2DPFM07414_12.dwg
REFERENCE DRAWINGS

NUMBER TITLE
2oo3 SHUTDOWN - UCP ESD
20198.COO.GEN.SDS ITEM NUMBERING
P&ID REPRESENTATION EXPANDED DETAILS
06215.COO.GEN.SDS FACILITY FUNCTIONAL UNITS

NOTES:
1. XALL AND XAHH AS APPLICABLE THE INITIATING VARIABLE (X) CAN BE ANY INITIATOR AS P.T.
OR L.

DISCREPANCY
XAHH XAHH 2oo3 XI UAD UAD
NOTE 1
B

XAHH XI XI XI XI XI
A A B C C

UCP ESD UCP


IZ IZ

2oo3

XT XT XT XT XT XT
A B C A B C

2oo3 SHUTDOWN - ESD

P&ID REPRESENTATION EXPANDED DETAILS

DISCREPANCY
XAHH 2oo3
UAD
NOTE 1

XAHH XI XI XI
A B C

ESD ESD
IZ IZ

2oo3

XT XT XT XT XT XT
A B C A B C

EX-DE 01 09/08/19 Issue for HAZOP (IFH) P. Martinez J. Dominguez A.Loza G. Vallerga R.Milani
EX-DE 00 29/05/19 Issue for comments (IFC) O. Nava J. Dominguez A.Loza G. Vallerga R.Milani
Validity Revision
Status Number Contractor Contractor Contractor Company Company
Date Description
Prepared Verified Approved Checked Approved
Index Revision
Company Logo and Business Name Project Name Company Document ID:
Mexico Area 1 –
Development Project 6006C2DPFM07414
Eni Mexico Job N.
Contractor Logo and Business Name Contractor Document ID:

J. Ray McDermott de México S.A de C.V.


Contractor N. 5000015145-A8156
Facility and Sub Facility Name Scale Sheet of Sheets

MEXICO AREA 1- AMOCA WHP1 n.a. 13/18

Document Title Superseeded N. 6006C2BPFM02135 Sh.13


WELLHEAD PLATFORM
Superseeded by N. CPY
PIPING & INSTRUMENTATION DIAGRAM Plant Area Unit
SYMBOLS n.a. n.a.

This document is property of eni ghana exploration and production ltd. It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent. Software: Autocad File Name: 6006C2DPFM07414_13.dwg
ELECTRIC USERS CONNECTED TO ESD/DCS REFERENCE DRAWINGS

NUMBER TITLE
TYPICAL: MOT-1 TYPICAL: MOT-2 TYPICAL: MOT-3
20198.COO.GEN.SDS ITEM NUMBERING
EXPANDED DETAILS P&ID REPRESENTATION EXPANDED DETAILS P&ID REPRESENTATION EXPANDED DETAILS P&ID REPRESENTATION
09215.COO.GEN.SDS FACILITY FUNCTIONAL UNITS

ESD ESD ESD


IZ IZ IZ

M IL PB NOTES:
M M ON M M M 1. CONNECTION BETWEEN DCS AND MCC SHOULD BE ALSO VIA SERIAL LINK.IT DEPENDS BY
PB IL THE MCC TECHNOLOGY
MCC
ESD
XS HS
ESD ESD MCC ESD ESD ESD
XS IZ PB IL IZ XS IZ
MCC MCC MCC MCC MCC

TYP. MOT-1 IL PB TYP. MOT-2 TYP. MOT-3

PCS PCS OFF PCS DCS DCS


I FROM I FROM LSD I FROM I FROM I FROM
MAIN/STAND BY MAIN/STAND BY I MAIN/STAND BY MAIN/STAND BY MAIN/STAND BY
SELECTOR HS-NNN SELECTOR HS-NNN SELECTOR HS-NNN SELECTOR HS-NNN SELECTOR HS-NNN
PCS
I
LOCAL CONTROL FROM
ENABLE START/STOP MAIN/STAND BY UNAVAILABLE RUNNING/STOPPED
SELECTOR HS-NNN
MHSL MHSY LOCAL CONTROL MUAP MULH
ENABLE START/STOP
PCS
MHSL MHSY

UNAVAILABLE RUNNING/STOPPED
UNAVAILABLE RUNNING/STOPPED
MUAP MULH
MUAP MULH

MHSB

AUT/MAN

TYPICAL: MOT-7 TYPICAL: HEATER-1 TYPICAL: COOLER-2

EXPANDED DETAILS P&ID REPRESENTATION EXPANDED DETAILS P&ID REPRESENTATION EXPANDED DETAILS P&ID REPRESENTATION

ESD ESD ESD


IZ IZ IZ

M IL PB
M M VSHH M
ON
PB IL NNNA
MCC
ESD
XS HS
MCC ESD ESD ESD ESD ESD
PB IL IZ XS IZ XS IZ
MCC MCC MCC MCC MCC
DCS
I
IL PB TYP. MOT-7 TYP. HEATER-1 TYP. COOLER-2

OFF PCS DCS DCS DCS DCS


I I I I I
(START/STOP)
LSD
I
VAHH
PCS
I
LOCAL CONTROL
UNAVAILABLE RUNNING/STOPPED ENABLE START/STOP
LOCAL CONTROL MUAP MULH MHSL MHSY
ENABLE START/STOP
PCS
MHSL MHSY

UNAVAILABLE RUNNING/STOPPED
UNAVAILABLE (TRIP) RUNNING/STOPPED
MUAP MULH
MUAP MULH

MHSB MHSB

AUT/MAN AUT/MAN

TYPICAL: TCP TYPICAL: VSD-1 TYPICAL: COOLER-3

EXPANDED DETAILS P&ID REPRESENTATION EXPANDED DETAILS P&ID REPRESENTATION EXPANDED DETAILS P&ID REPRESENTATION

ESD ESD ESD


IZ IZ IZ
M M

M VSHH M
ESD ESD NNNA
XS IZ
VSD VSD

ESD ESD ESD ESD


XS IZ TYP. VSD XS IZ
TCP TCP MCC MCC
DCS
I
DCS DCS
I FROM I
TYP. TCP MAIN/STAND BY TYP. COOLER-3
SELECTOR HS-NNN FROM
DCS DCS DCS DCS
I I MAIN/STAND BY I I
SELECTOR HS-NNN
LOCAL CONTROL
ENABLE START/STOP
VAHH
MHSL MHSY
LOCAL CONTROL EX-DE 01 09/08/19 Issue for HAZOP (IFH) P.Martinez J. Dominguez A.Loza G. Vallerga R.Milani
UNAVAILABLE RUNNING/STOPPED ENABLE START/STOP EX-DE 00 29/05/19 Issue for comments (IFC) O.Nava J. Dominguez A.Loza G. Vallerga R.Milani
Validity Revision
MUAP MULH Contractor Contractor Contractor Company Company
MHSL MHSY Status Number Date Description
Approved Checked Approved
Prepared Verified
Index Revision
UNAVAILABLE RUNNING/STOPPED Company Logo and Business Name Project Name Company Document ID:
MUAP MULH Mexico Area 1 –
Development Project 6006C2DPFM07414
UNAVAILABLE RUNNING/STOPPED Eni Mexico Job N.

MULH Contractor Logo and Business Name Contractor Document ID:


MUAP
SPEED/LOAD
MANUAL CONTROL SPEED/LOAD
J. Ray McDermott de México S.A de C.V.
MHIC MSI Contractor N. 5000015145-A8156
Facility and Sub Facility Name Scale Sheet of Sheets

MEXICO AREA 1- AMOCA WHP1 n.a. 14/18

MHSB Document Title Superseeded N. 6006C2BPFM02135 Sh.14


WELLHEAD PLATFORM
Superseeded by N. CPY
PIPING & INSTRUMENTATION DIAGRAM Plant Area Unit
AUT/MAN SYMBOLS n.a. n.a.

This document is property of eni ghana exploration and production ltd. It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent. Software: Autocad File Name: 6006C2DPFM07414_14.dwg
REFERENCE DRAWINGS

NUMBER TITLE

20198.COO.GEN.SDS ITEM NUMBERING


ELECTRIC USERS CONNECTED TO UCP
06215.COO.GEN.SDS FACILITY FUNCTIONAL UNITS
TYPICAL: MOT-4 TYPICAL: MOT-5 TYPICAL: MOT-6

EXPANDED DETAILS P&ID REPRESENTATION EXPANDED DETAILS P&ID REPRESENTATION EXPANDED DETAILS P&ID REPRESENTATION
NOTES:
UCP-ESD UCP-ESD ESD
IZ I IZ 1. CONNECTION BETWEEN UCP AND MCC SHOULD BE ALSO VIA SERIAL LINK. IT DEPENDS BY
THE MCC TECHNOLOGY

M M M M M M

UCP-ESD UCP-ESD UCP-ESD UCP-ESD ESD


XS IZ XS IZ XS IZ
MCC MCC MCC MCC MCC MCC

TYP. MOT-4 TYP. MOT-5 TYP. MOT-6

UCP UCP UCP UCP UCP UCP


I FROM I FROM I FROM I FROM I FROM I FROM
MAIN/STAND BY MAIN/STAND BY MAIN/STAND BY MAIN/STAND BY MAIN/STAND BY MAIN/STAND BY
SELECTOR HS-NNN SELECTOR HS-NNN SELECTOR HS-NNN SELECTOR HS-NNN SELECTOR HS-NNN SELECTOR HS-NNN

LOCAL CONTROL LOCAL CONTROL


ENABLE START/STOP ENABLE START/STOP
MHSLU MHSY MHSLU MHSYU

UNAVAILABLE RUNNING/STOPPED UNAVAILABLE RUNNING/STOPPED UNAVAILABLE RUNNING/STOPPED


MUAPU MULHU MUAPU MULHU MUAPU MULHU

MUAP MHSBU MULH MUAP MHSYU MULH MUAP MHSBU MULH

AUT/MAN START/STOP AUT/MAN

TYPICAL: COOLER-1 TYPICAL: VSD-2 TYPICAL: HEATER-2

EXPANDED DETAILS P&ID REPRESENTATION EXPANDED DETAILS P&ID REPRESENTATION EXPANDED DETAILS P&ID REPRESENTATION
UCP-ESD
IZ UCP-ESD
UCP-ESD IZ
IZ

M M
M M

UCP-ESD
UCP-ESD
XS IZ UCP-ESD
UCP-ESD UCP-ESD VSD VSD XS IZ UCP-ESD
XS IZ
MCC MCC MCC MCC
TYP. VSD
TYP. COOLER-1 TYP. HEATER-2
UCP UCP
FROM FIC - NNN I FROM I UCP
UCP UCP I UCP
I I (OR LIC OR PIL) MAIN/STAND BY I
(START/STOP)
SELECTOR HS-NNN FROM
LOCAL CONTROL MAIN/STAND BY
ENABLE START/STOP SELECTOR HS-NNN
MHSLU MHSYU
LOCAL CONTROL
ENABLE START/STOP UNAVAILABLE RUNNING/STOPPED
MHSLU MHSYU MUAP MUAPU MULHU MULH

UNAVAILABLE RUNNING/STOPPED
MUAP MUAPU MULHU MULH
UNAVAILABLE RUNNING/STOPPED
MUAPU MULHU
SPEED/LOAD
MANUAL CONTROL SPEED/LOAD
MHICU MSIU

MUAP MHSBU MULH MHSBU

AUT/MAN AUT/MAN

TYPICAL: SEAL PLAN

EXPANDED DETAILS P&ID REPRESENTATION

SEAL
PT PI PLAN

PT PI

LT LI
M LT LI
EX-DE 01 09/08/19 Issue For HAZOP (IFH) P.Martinez J.Dominguez A.Loza G.Vallerga R.Milani
EX-DE 00 29/05/19 Issue For Comments (IFC) O.Nava J.Dominguez A.Loza G.Vallerga R.Milani
M Validity
Status
Revision
Number Contractor Contractor Contractor Company Company
Date Description
Prepared Verified Approved Checked Approved
Index Revision
Company Logo and Business Name Project Name Company Document ID:
Mexico Area 1 –
Development Project 6006C2DPFM07414
Eni Mexico Job N.
Contractor Logo and Business Name Contractor Document ID:

J. Ray McDermott de México S.A de C.V.


Contractor N. 5000015145-A8156
1 2
Facility and Sub Facility Name Scale Sheet of Sheets

MEXICO AREA 1- AMOCA WHP1 n.a. 15/18


1. COOLING WATER IN
Document Title Superseeded N. 6006C2BPFM02135 Sh.15
2. COOLING WATER OUT WELLHEAD PLATFORM
Superseeded by N. CPY
PIPING & INSTRUMENTATION DIAGRAM Plant Area Unit
SYMBOLS n.a. n.a.

This document is property of eni ghana exploration and production ltd. It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent. Software: Autocad File Name: 6006C2DPFM07414_15.dwg
REFERENCE DRAWINGS
SAMPLE POINT TYPE "B3" SAMPLE POINT TYPE "D3"
FOR LIQUID HYDROCARBON AND GLYCOL SAMPLES ABOVE 60 °C FOR LIQUID HYDROCARBON AND GLYCOL SAMPLES BELOW 60 °C
ON PROCESS EQUIPMENT WITH RATING ≥ 600# AND H S SERVICE ON PROCESS EQUIPMENT WITH RATING ≤ 300#

EXPANDED DETAILS P&ID REPRESENTATION EXPANDED DETAILS P&ID REPRESENTATION

PORTABLE SAMPLE RECEIVER

TO CLOSED/GLYCOL GENERAL NOTES:


DRAIN SYSTEM

PI PI TYP. "D3"

STAINLESS STEEL
1. PROVIDE VALVE DRAINS AT THE LINE LOWEST POINTS AND VALVED VENTS AT THE LINE HIGHEST POINTS.
SP

PROCESS SPEC
XXX 2. CD LINES WHICH ARE CONNECTED TO THE CLOSED DRAIN NETWORK SHALL BE SLOPED, NO POCKET LINES.
1/2"x1/4" 1/2"x1/4"
TYP. "B3"
1/4" 1/4" 1/2" 3. LINES WHICH ARE CONNECTED TO THE OPEN DRAIN NETWORK SHALL BE SLOPED, NO POCKET LINES.
LS
XXX SP
XXX
1/2"

1/4"

PROCESS 1" PROCESS SPEC


EQUIPMENT D
STAINLESS STEEL
THERMAL 1"
EXPANSION LOOP NOTES:
1/4"

1"x3/4"
1. PREFERRED SAMPLE TAKE OFF POSITIONIS FROM A VERTICAL LINE, WHERE IS NOT POSSIBLE SAMPLE TAKE
TAKE OFF SHALL BE INSTALLED AT SIDE OF THE PIPE IN 4 O´CLOCK POSITION.
1/4"
3/4" 2. FREQUENTLY USED SAMPLE CONNECTIONS TO BE LOCATED AT GRADE LEVEL WHERE POSSIBLE.
3. SAMPLE BOTTLE TO BE SUPPLIED COMPLETE WITH METALLIC HOSES AND QUICK CONNECTIONS BOTH
HOLD 1 D ENDS.
1/4" 4. SAMPLE LINE TO BE INSULATED FOR PERSONNEL PROTECTION UPSTREAM OF COOLER.
5. MINIMIZE DISTANCE FROM PROCESS TAKE-OFF TO SAMPLE CONNECTION.

INSTRUMENT
6. FREQUENTLY USED SAMPLE CONNECTIONS TO BE LOCATED AT GRADE LEVEL WHERE POSSIBLE.
3/4" 1"

1/2" MNPT x 1/2" O.D. TUBING CONNECTOR

PIPING
INSTRUMENT

PI
1" ASME CLASS 2500 RJ BLIND FLANGE
S
CENTER DRILLED & TAPPED W/ 1/2" FNPT 1"
PIPING

1/2" NPT-F

CLOSED DRAINS SAMPLE BOTTLE


(VERTICAL)

(NOTE 2, 6)
SAMPLE PROBE
(SPECIAL PART)

PROCESS LINE

SAMPLE POINT TYPE "D4"


FOR LIQUID HYDROCARBON AND GLYCOL SAMPLES BELOW 60 °C
ON PROCESS EQUIPMENT WITH RATING ≥ 600# AND H2S SERVICE

EXPANDED DETAILS P&ID REPRESENTATION

TO CLOSED/GLYCOL
DRAIN SYSTEM

TYP. "D4"
SP
XXX

PROCESS
EQUIPMENT

1"
PROCESS SPEC
STAINLESS STEEL
D 1"

PROCESS SPEC 1"


STAINLESS STEEL
1"x3/4"
3/4"

HOLD 1

3/4" 1"

PI 1"

EX-DE 01 09/08/19 Issue For HAZOP (IFH) P.Martinez J.Dominguez A.Loza G.Vallerga R.Milani
EX-DE 00 29/05/19 Issue For Comments (IFC) O.Nava J.Dominguez A.Loza G.Vallerga R.Milani
Validity Revision
Contractor Contractor Contractor Company Company
1/2" NPT-F Status Number Date Description
Prepared Verified Approved Checked Approved
Index Revision
Company Logo and Business Name Project Name Company Document ID:
SAMPLE BOTTLE
Mexico Area 1 –
(VERTICAL) Development Project 6006C2DPFM07414
Eni Mexico Job N.
(NOTE 2, 6)
Contractor Logo and Business Name Contractor Document ID:

J. Ray McDermott de México S.A de C.V.


Contractor N. 5000015145-A8156
Facility and Sub Facility Name Scale Sheet of Sheets

MEXICO AREA 1- AMOCA WHP1 n.a. 16/18

Document Title Superseeded N. 6006C2BPFM02135 Sh.16


WELLHEAD PLATFORM Superseeded by N. CPY
PIPING & INSTRUMENTATION DIAGRAM Plant Area Unit
SIMBOLS n.a. n.a.

This document is property of eni ghana exploration and production ltd. It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent. Software: Autocad File Name: 6006C2DPFM07414_16.dwg
REFERENCE DRAWINGS
SAMPLE POINT TYPE "C1" SAMPLE POINT TYPE "D1"
FOR GAS SAMPLES ON PROCESS LINE WITH RATING < 300# FOR LIQUID HYDROCARBON AND GLYCOL SAMPLES BELOW 60 °C
ON PROCESS LINE WITH RATING ≤ 300#

EXPANDED DETAILS P&ID REPRESENTATION EXPANDED DETAILS P&ID REPRESENTATION

PROCESS LINE GENERAL NOTES:


TYP. "C1" (NOTE 3)
V (NOTE 2)
TO FLARE SYSTEM SP FROM TO CLOSED/GLYCOL 1. PROVIDE VALVE DRAINS AT THE LINE LOWEST POINTS AND VALVED VENTS AT THE LINE HIGHEST POINTS.
BOTTOM MIN. DRAIN SYSTEM
XXX 2. CD LINES WHICH ARE CONNECTED TO THE CLOSED DRAIN NETWORK SHALL BE SLOPED, NO POCKET LINES.

3. SY LINES WHICH ARE CONNECTED TO THE OPEN DRAIN NETWORK SHALL BE SLOPED, NO POCKET LINES.
STAINLESS STEEL HIGH POINT 1" PROCESS SPEC
TYP. "D1"
PROCESS SPEC 1" STAINLESS STEEL SP
FROM NOTES:
XXX
(NOTE 2) MIN. TOP
(NOTE 3)
D 1. SAMPLE BOTTLE TO BE SUPPLIED WITH METALLIC HOSES AND QUICK CONNECTORS
PROCESS LINE PROCESS SPEC AT BOTH ENDS.
STAINLESS STEEL PROCESS SPEC
1" 2. MINIMIZE DISTANCE FROM PROCESS TAKE-OFF TO SAMPLE CONNECTION.
STAINLESS STEEL
1"
3. PREFERRED TAKE OFF POSITION IS FROM A VERTICAL LINE. WHERE IS NOT POSSIBLE SAMPLE TAKE OFF
SHALL BE INSTALLED AT THE TOP OF THE PIPE.
1"x3/4" 4. FREQUENTLY USED SAMPLE CONNECTIONS TO BE LOCATED AT GRADE LEVEL WHERE POSSIBLE.
1"x3/4"

3/4"
3/4"
V
HOLD 1 D

3/4" 1"
3/4" 1"

PI
S PI
1" S
1"

1/2" NPT-F
1/2" NPT-F
SAMPLE BOTTLE
(HORIZONTAL) SAMPLE BOTTLE
(VERTICAL)
(NOTE 1,4)
(NOTE 1,4)

SAMPLE POINT TYPE "C2" SAMPLE POINT TYPE "D2"


FOR LIQUID HYDROCARBON AND GLYCOL SAMPLES BELOW 60 °C
FOR GAS SAMPLES ON PROCESS LINE WITH RATING ≥600# AND H 2S SERVICE ON PROCESS LINE WITH RATING ≥ 600# AND H2S SERVICE

EXPANDED DETAILS P&ID REPRESENTATION EXPANDED DETAILS P&ID REPRESENTATION


STAINLESS STEEL

PROCESS LINE
PROCESS SPEC

TYP. "C2" (NOTE 3)


(NOTE 2)
SP FROM TO CLOSED DRAIN
BOTTOM MIN. SYSTEM
V XXX
TO FLARE SYSTEM

1" PROCESS SPEC


TYP. "D2"
STAINLESS STEEL SP
HIGH POINT
XXX
1"
D
FROM
(NOTE 2) MIN. TOP
(NOTE 3) PROCESS SPEC
PROCESS LINE PROCESS SPEC 1" STAINLESS STEEL
PROCESS SPEC 1"
STAINLESS STEEL
1" STAINLESS STEEL

1"x3/4"
1"x3/4"

3/4"
3/4"
HOLD 1
HOLD 1
D
V

3/4" 1"
3/4" 1"

PI 1"
PI 1" S
S
EX-DE 01 09/08/19 Issue For HAZOP (IFH) P.Martinez J.Dominguez A.Loza G.Vallerga R.Milani
EX-DE 00 29/05/19 Issue For Comments (IFC) O.Nava J.Dominguez A.Loza G.Vallerga R.Milani
1/2" NPT-F Validity Revision
Status Number Contractor Contractor Contractor Company Company
Date Description
1/2" NPT-F Index Revision
Prepared Verified Approved Checked Approved

SAMPLE BOTTLE Company Logo and Business Name Project Name Company Document ID:
SAMPLE BOTTLE (VERTICAL) Mexico Area 1 –
Development Project 6006C2DPFM07414
(HORIZONTAL) (NOTE 1,4) Eni Mexico Job N.
(NOTE 1,4) Contractor Logo and Business Name Contractor Document ID:

J. Ray McDermott de México S.A de C.V.


Contractor N. 5000015145-A8156
Facility and Sub Facility Name Scale Sheet of Sheets

MEXICO AREA 1- AMOCA WHP1 n.a. 17/18

Document Title Superseeded N. 6006C2BPFM02135 Sh.17


WELLHEAD PLATFORM
Superseeded by N. CPY
PIPING & INSTRUMENTATION DIAGRAM Plant Area Unit
SYMBOLS n.a. n.a.

This document is property of eni ghana exploration and production ltd. It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent. Software: Autocad File Name: 6006C2DPFM07414_17.dwg
REFERENCE DRAWINGS
SAMPLE POINT TYPE "C3" DETAIL 1
NON-HAZARDOUS LIQUID SAMPLES WITH ATM. BOILING TEMPERATURES INSTRUMENT & MEG INJECTION CONNECTIONS - PRODUCTION WELLHEADS
ABOVE THE SAMPLE TEMPERATURE FOR ALL POSSIBLE COMPOSITIONS (TYPICAL FOR 4 WELLHEADS)

EXPANDED DETAILS P&ID REPRESENTATION TYPICAL DETAIL - SIDE VIEW P&ID REPRESENTATION

PT/TT

PG
GENERAL NOTES:
A. PROVIDE VALVE DRAINS AT THE LINE LOWEST POINTS AND VALVED VENTS AT THE LINE HIGHEST
PROCESS LINE

MANUAL POINTS.
WING B. CD LINES WHICH ARE CONNECTED TO THE CLOSED DRAIN NETWORK SHALL BE SLOPED, NO
VALVE "A" POCKET LINES.
1 1/2" TYP. "C3"

PRODUCTION
C. LINES WHICH ARE CONNECTED TO THE OPEN DRAIN NETWORK SHALL BE SLOPED, NO POCKET

WELLHEAD
SP
PI PT TT LINES.
XXX

"A" WV

X
600mm MIN.

1 1/2" x 1/2" NOTES:

4 1/16" API 10000 RJ

(BY FMC)
INSTRUMENT FLANGE
1. MINIMUM DISTANCE FOR BOTTLE.

1 - CLARIFY HOW TO SUPPORT


2 - SPECIFY IN A NOTE, DISSIMILAR
1/2" CHECK VALVE
3 - TO BE REVISED, WITHOUT BLIND
1/2" x 1/4" MEG FLANGE.
INJECTION
INSTR. PIPING PIPING INSTR.
PG PT/TT
500

TO OPEN DRAINS SYSTEM


1/2"

9/16" AUTOCLAVE 9/16" AUTOCLAVE

4 1/16" API 10000 RJ


1" AUTOCLAVE
INSTRUMENT FLANGE
(BY FMC)

SP 019 NOT IN SP LIST MALE x MALE


AUTOCLAVE ADAPTER 1" AUTOCLAVE
W/ PLUG
1"-SP-019 DBB WITH
INTEGRAL CHECK VALVE

X
ASME CLASS 10000 RJ x 1"
3 AUTOCLAVE
1
1" ASME CLASS 10000 RJ BLIND FLANGE,
ASTM A182 GR. F51 DUPLEX SS, SECTION "A-"A"
CENTER DRILLED & TAPPED
1"-FUJD
CLARIFY, NOT IN VALVE LIST
MEG 2
INJECTION

DETAIL 2 DETAIL 3
INSTRUMENT CONNECTIONS AT PRODUCTION CASING - PRODUCTION WELLHEADS INSTRUMENT CONNECTIONS - WATER INJECTION WELLHEADS
(TYPICAL FOR 4 WELLHEADS) (TYPICAL FOR 5 WELLHEADS)

TYPICAL DETAIL - SIDE VIEW P&ID REPRESENTATION TYPICAL DETAIL - SIDE VIEW P&ID REPRESENTATION

PT/TT PT

PG
PG
PI PT TT
PI PT

HV MANUAL
CASING GAS WING
"A" CHOKE VALVE "A"

WATER INJECTION
VALVE
PRODUCTION

WELLHEAD
WELLHEAD

"A" "A"
5 1/8" API 10000 RJ

(BY FMC)
INSTRUMENT FLANGE
CGV WV

MANUAL
PRODUCTION 2 1/16" API 5000 RJ
CASING VALVE INSTRUMENT FLANGE
(BY FMC)

INSTR. PIPING PIPING INSTR.


PG PT/TT PG PT

9/16" AUTOCLAVE 9/16" AUTOCLAVE 9/16" AUTOCLAVE 9/16" AUTOCLAVE

2 1/16" API 10000 RJ


INSTRUMENT FLANGE
(BY FMC)
5 1/8" API 10000 RJ
1" AUTOCLAVE INSTRUMENT FLANGE
MALE x MALE (BY FMC)
EX-DE 01 09/08/19 Issue For HAZOP (IFH) P.Martinez J.Dominguez A.Loza G.Vallerga R.Milani
AUTOCLAVE ADAPTER
9/16" AUTOCLAVE 1,2,3 1" AUTOCLAVE
EX-DE
Validity
00
Revision
29/05/19 Issue For Comments (IFC) O.Nava J.Dominguez A.Loza G.Vallerga R.Milani
W/ PLUG W/ PLUG 1" AUTOCLAVE Status Number Contractor Contractor Contractor Company Company
Date Description
1"-SP-019 DBB WITH W/ PLUG Index Revision
Prepared Verified Approved Checked Approved

INTEGRAL CHECK VALVE Company Logo and Business Name Project Name Company Document ID:
X

ASME CLASS 10000 RJ x 1" Mexico Area 1 –


AUTOCLAVE Development Project 6006C2DPFM07414
Eni Mexico Job N.

1" ASME CLASS 10000 RJ BLIND FLANGE, Contractor Logo and Business Name Contractor Document ID:
SECTION "A-"A" SECTION "A-"A"
ASTM A182 GR. F51 DUPLEX SS,
CENTER DRILLED & TAPPED J. Ray McDermott de México S.A de C.V.
1"-FUJD Contractor N. 5000015145-A8156
Facility and Sub Facility Name Scale Sheet of Sheets

MEG MEXICO AREA 1- AMOCA WHP1 n.a. 18/18


INJECTION
Document Title Superseeded N. 6006C2BPFM02135 Sh.18
WELLHEAD PLATFORM
Superseeded by N. CPY
PIPING & INSTRUMENTATION DIAGRAM Plant Area Unit
SYMBOLS n.a. n.a.

This document is property of eni ghana exploration and production ltd. It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent. Software: Autocad File Name: 6006C2DPFM07414_18.dwg
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

REFERENCE DRAWINGS
LINES
NUMBER TITLE
A SYMBOL DESCRIPTIONSYMBOL DESCRIPTION SYMBOLDESCRIPTIONSYMBOL DESCRIPTION SYMBOL DESCRIPTIONSYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION A

SWING OUT FLAME GLYCOL GRAVITY COFFEE MACHINE COOLING


20198.COO.GEN.SDS ITEM NUMBERING COMPANY SPECIFICATION
FROM/TO UNIT CROSSOVER BASKET GAS BAG FILTER COOLING WATER SUPERHEATER OR DIAPHRAGM PUMP
LINES STRAINER BURNER REGENERATOR CHILLER WITH BLADE AIR TOWER, HUMID HEATER
CONDENSER LOCK TYPE-
COFFEE MACHINE
NATURAL
DRAFT

PRODUCT RUBBER LINE ACTIVE CARBON ROTARY VACUUM BURNER ELECTRIC GLYCOL FIRE BARRIER WASHING MACHINE COOLING WASTE HEAT METERING PUMP
INLET OR FLEXIBLE RECOVERY BASKET FILTER (GENERAL) REGENERATOR TOWER, DRY RECOVERY
MATERIAL FILTER TYPE- UNIT NOTES:
WASHING MACHINE
NATURAL
DRAFT
1. SYMBOL TO BE APPLIED TO MULTIPHASE PUMP.

B PRODUCT UNDERGROUND CARTRIDGE FILTER B


VACUUM HEATING COIL INJECTION PUMP
WATER AIR LOCK WITH BIDET
OUTLET PIPE (GENERAL HORIZONTAL EQUIPMENT CHILLER WITH PARALLEL BLADES TUBE APPLIED

SYMBOL) FILTER TO
Class G SEPARATE
BIDET EQUIPMENT
AIR
CONDENSER
SYMBOL DESCRIPTION SYMBOL DESCRIPTION
SUPPLY LIMIT OPERATING TEMP.DESING
°C DUPLEX FILTER AIR ANDLING VERTICAL
ELECTROSTATIC AIR LOCK WITH WATER CLOSET
PRESSURE AND PRECIPITATOR UNIT TWO OPPOSITE BLADES EQUIPMENT M SUBMERSIBLE
OPER/DESIGN DUCT CENTRIFUGAL
TEMPERATURE SYSTEM W.C.
Class K
PUMP

MAX. DES. TEMP.°C (EXTERNAL


M
DES. PRESS. barg SYMBOL DESCRIPTION SYMBOL DESCRIPTION MOTOR)

DIRECTION OF GENERAL FROM/TO SAND (MULTIMEDIA) M


WATER CHILLER MIXING BOX TOILET SINK CENTRIFUGAL INSTRUMENT AIR BARREL PUMP
FILTER PRESS
C FLOW: FILTER COMPRESSOR COMPRESSOR M C
A A XXXXXXXXXXX WITH AIR

MB
A=ONE WAY M
CONDENSER
TOILET SINK M
FLOW
B B XXXXXXXXXXX
B=FLOW
DOUBLE SENSE

PACKAGE LIMIT HOT INSULATED SAND FILTER CENTRIFUGAL ROTARY


BELT TYPE FILTER AIR HANDLING UNIT PRESSURE SHOWER EJECTION PUMP
LINE REDUCING BOX COMPRESSOR COMPRESSOR
ALL AIR

PR
SHOWER

LINE CHANGE / COLD ACTIVE CARBON SEPARADOR HIGH EFFICIENCY CENTRIFUGAL FAN DRINKING WATER KITCHEN SINK 2 PHASE SCREW HAND PUMP
A00 A00 SPECIF.CHANGE INSULATED FILTER SCREEN AIR FILTER CENTRIFUGAL COMPRESSOR
M
(IN DUCT) BOILER
D LINE (GENERAL) COMPRESSOR D
KITCHEN SINK

PRINCIPAL LINE JACKETED LINE COALESCER ROLL TYPE FILTER AXIAL FAN OR 3 PHASE LOBE SUBMERSIBLE
SLIDE GATE AIR GENERAL SYMBOL WASH-TUB
(SP. 0.8 mm) BLOWED (IN CENTRIFUGAL COMPRESSOR PUMP
HANDLING
UNIT ALL AIR DUCT) COMPRESSOR (SUBMERSED
XXXXXXXXXXXXX
WASH-TUB
PRE-HEATING MOTOR)
M COIL
M

SECONDARY LINE TRACED LINE STATIC BEND GRID M BAG FILTER RECIPROCATING SLIDING VANE VACUUM PUMP
VESSELWITH
VESSEL WITH MOISTURE DISH WASHER
(SP. 0.4 mm) BY EXTERNAL SEPARATOR COMPRESSOR COMPRESSOR
DEMISTER/
HOT FLUID COALESCENCE
E
DISH WASHER V E
SEPARATOR

FUTURE LINE ELECTRIC TRACED PLATE SCREEN MACERATOR/ ROOF TOP AIR FLAT AIR FILTER HUMIDIFIER
HUMIDIFIER 2 STAGE FAN (GENERAL) SLURRY PUMP
(SP. 0.4 mm) LINE COMMINUTOR EQUIPMENT RECIPROCATING
HANDLING UNIT (INSTALLED
COMPRESSOR
OUTSIDE DUCT) Class H
LCPP
M

SYMBOL DESCRIPTION SYMBOL DESCRIPTION


SLOPED LINE HOT RAW GAS FILTER HEAT EXCHANGER AIR COOLER AXIAL TURBINE PUMP
FIRE HUMIDIFIER
HUMIDIFIER 3 STAGE
INSULATED (GENERAL) WITH COMPRESSOR
00 % RESISTANT (INSTALLED IN RECIPROCATING
INTERNAL ACTUATED COMPRESSOR
CLASS I AIR DUCT)
HOT FLUID LOCK GATE T
FILTER
F F

NO POCKET LINE EQUIPMENT FILTER SELFCONTAINED DRINKING WATER HEAT EXCHANGER BOX COOLER PYSTON ARCHIMEDEAN
ANTIGREASE
INSULATION (GENERAL SYMBOL) STERILIZER (GENERAL) SINGLE COIL COMPRESSOR
AIR FILTER FOR OR VOLUTE
NO POCKET HANDLING (UV TYPE)
KITCHEN SCREW PUMP
F M M UNIT SPLIT HOOD
TYPE

INTERSECTING SKID LIMIT NATURAL HEAT EXCHANGER ECCENTRIC PUMP


DEMINERALIZATION JACKETED HEAT
LINES EQUIPMENT DRAFT COIL (ONE PASS) EQUIPMENT
UNIT EXCHANGER

Class D Class M

G SYMBOL DESCRIPTIONSYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION G


DOUBLE SINGLE SELF FAN-COIL HEATING COIL HEAT EXCHANGER BOX EXCHANGER DIESEL ENGINE GAS TURBINE
SYMBOL EXPANDED DETAIL
DESCRIPTION (TWO PASS)
COMPLETION COMPLETION CONTAINED
HOOK UP HOOK UP HOOK UP LIMIT WELL HEAD WELL HEAD AIR
MM MD
XXX XXX HANDLING
UNIT
LINE TO BE ASSEMBLEDLINE TO BE ASSEMBLED
ON SITE (ON-SHORE)
AT PLATFORM (OFF-SHORE)

HOT FLUID HEATER COOLING COIL REBOILER KETTLE GAS ENGINE HYDRAULIC
WATER SPRAY
EQUIPMENT EQUIPMENT TYPE COOLER TURBINE

Class C Class F M MG

SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTIONSYMBOL DESCRIPTION


H CYCLONE SCALING DIRECT FIRE FURNACE CHILLED FLUID ELECTRIC HEATING REBOILER KETTLE TURBO EXPANDER STEAM H
"PRIMARY AIR" FINNED TUBE
WEIGHING HEATER HEATER TYPE RECIPROCATING
(GENERAL) AIR HANDLING COIL (INCLUDING
MACHINE UNIT DRIVER
HEATER V
M SERIES)
EXCHANGER
M
VERTICAL BASCULE INDIRECT FIRE WATER TUBES HOT FLUID HEATER TRANSFER GRILL WATER COOLER TURBINE WITH EXPANSION
M DESUPERHEATER
CENTRIFUGE HEATER BOILER WITH EXTERNAL INTERMEDIATE TURBINE
GRILLE BLEEDING

HORIZONTAL SUCTION HOOD CABYN TYPE FIRE TUBES BOILER WINDOW TYPE AIR ELECTRIC HEATER LINEAR SUPPLY BUILT-IN ELECTRIC
L
DECANTER FURNACE
HANDLING UNIT DIFFUSER REBOILER IN EXCHANGER EQUIPMENT L
CENTRIFUGE
VESSELS/ Class P
COLUMNS

SYMBOL DESCRIPTION SYMBOL DESCRIPTION


JET MIXER, AIR TURBINE CYLINDRICAL DRUM BOILER ELECTRIC CENTRIFUGAL LOBE PUMP
EXHAUST INLET STEAM HEATER ELECTRIC GAS
INJECTOR, VERT-TYPE RADIATOR PUMP
LOUVER WITH AIR HEATER HOT
EJECTOR, FURNACE LOCK OIL
EDUCTOR C

AIR DIFFUSOR REACTION FLARE FLUID TYPE


FLUID TYPE ELECTRIC HEATING CENTRIFUGAL ROTARY/GEAR
VENTURI WASHER REFRIGERATING SUPPLY RECOVERY BOILER
FURNACE RADIATING TUBE APPLIED TO PUMP
UNIT SPLIT LOUVER WITH PUMP (Note 1)
TYPE PANEL AIR LOCK EQUIPMENT
M M
C

STATIC MIXER ADJUSTABLE WEIR ELECTRIC BURNING PIT FLUID TYPE INLET AND OUTLET PLATE HEAT COOLING M 2 STAGE ROTARY/GEAR
RESISTENCE RADIATOR GRILLE EXCHANGER TOWER, HUMID CENTRIFUGAL PUMP
FURNACE TYPE - PUMP WITH
FORCED DRAFT INTERMEDIATE
EX-DE 01 09/08/19 Issue For HAZOP (IFH) P. Martinez J.Dominguez A.Loza G.Vallerga R.Milani
COOLING
EX-DE 00 29/05/19 Issue For Comments (IFC) O.Nava J.Dominguez A.Loza G.Vallerga R.Milani
Validity Revision
Status Number Contractor Contractor Contractor Company Company
SCREEN NATURAL ELECTRIC ARC CHIMNEY REFRIGERATING CENTRIFUGAL FAN AIR LOCK RECIPROCATING PROPELLER OR Date Description
AIR COOLER COOLING Prepared Verified Approved Checked Approved
DRAUGHT FURNACE (INSIDE UNIT) PUMP SCREW PUMP Index Revision
UNIT SPLIT TOWER, DRY
BURNER VENTURI TYPE WITH Company Logo and Business Name Project Name Company Document ID:
TYPE -
TYPE CONDENSER A
FORCED Mexico Area 1 –
N 6006C2DPFM07414 N
DRAFT DRAWING NUMBER:
Development Project
Eni Mexico Job N.

VIBRATING SCREEN HORIZONTAL ELECTRIC VENT AXIAL FAN BACK DRAFT PISTON PUMP SLIDING Contractor Logo and Business Name Contractor Document ID:
AIR COOLER WITH
BLADE INDUCTION (INSIDE UNIT) AIR LOCK VANE PUMP
LOUVRES
FLOCCULATOR FURNACE
J. Ray McDermott de México S.A de C.V.
Contractor N. 5000015145-A8156
Facility and Sub Facility Name Scale Sheet of Sheets

n.a. 2/18
AGITATOR / MIXER TURBINE CHEMICAL MEXICO AREA 1- AMOCA WHP1
FLOCCULATOR DOSING
(GENERAL) Document Title Superseeded N. 6006C2BPFM02135 Sh.02
PUMP
WELLHEAD PLATFORM
P Superseeded by N.CPY P
PIPING & INSTRUMENTATION DIAGRAM Plant Area Unit

SYMBOLS n.a. n.a.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

This document is property of eni ghana exploration and production ltd. It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent. Software: Autocad File Name:6006C2DPFM07414_02.dwg
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

REFERENCE DRAWINGS
EQUIPMENT EQUIPMENT EQUIPMENT
NUMBER TITLE
CLASS R CLASS L CLASS T
A A

SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION 20198.COO.GEN.SDS ITEM NUMBERING COMPANY SPECIFICATION

GLOBE VALVE PLUG VALVE SIGHT GLASS HAMER'S SPECTACLE CONCENTRIC REDUCER SPHERICAL PRESSURE ELECTRICALLY HEATED BIOREACTOR BAV SWIRL DECK
SYPHON CONE ROOF STORAGE FROM/TO UNIT
FLANGE STORAGE TANK PRESSURIZER
TANK

ANGLE GLOBE VALVE 3-WAY PLUG VALVE THERMOSTATIC STEAM SILENCER FLANGE CONNECTION VENT TO ATMOSPHERE SPHERICAL PRESSURE FROM/TO UNIT VANE PACK
DIAPHRAGM TANK PRESSURIZER WITH
TRAP
ATM
STORAGE TANK
SPRAY INJECTION EQUIPMENT
CLASS Y
B B
SYMBOL DESCRIPTION SYMBOL DESCRIPTION

ANGLE VALVE 4-WAY PLUG VALVE THERMODYNAMIC STEAM PULSATION DAMPER CONE BOTTOMED BIN ELECTRICALLY HEATER DEGASSER SCHOEPENTOETER
STORAGE TANK BRIDGE CRANE METALLIC BELT
SWAGE NIPPLE SWIVEL
TRAP (BULK STORAGE) PRESSURIZER WITH (VANE TYPE,SIDEWAYS
CONVEYOR
SPRAY INJECTION INLET DEVICE)

3-WAY VALVE JACKETED PLUG-VALVE STEAM TRAP WITH PRESSURIZED FLAT BOTTOMED BIN VACUUM TOWER LIQUID SPRAY
TEMPERATURE OPEN DRAIN ATMOSPHERIC STORAGE EXPANSION TANK SKIP HOIST HOPPER
FLOAT EXPANSION VESSEL (BULK STORAGE) (PERFORATED PIPE)
THERMO-WELL CONCENTRIC REDUCER
(FUNNEL)
MIN
4"

C C
4-WAY VALVE PROPORTIONING VALVE STEAM TRAP WITH FLAME ARRESTOR CRANE BOTTOM TANK OPEN TOP-CONE/ LIQUID SPRAY
VENT TO ATMOSPHERE HOOK UP WITH GAS SCRUBBER DRIER (GENERAL) HANDLING EQUIPMENT SCREW CONVEYOR
INTEGRAL CHECK PYRAMID BOTTOMED (NOZZLE TYPE)
FLANGED SPOOL PIECE (GENERAL)
VALVE (BUCKET TYPE) HOOK UP N. BIN

ATM

BALL VALVE EXCESS FLOW VALVE EXPANSION JOINT CHOKING FLAME OPEN TOP SOLID BATCH TRAYS DRIER TOTAL DRAW-OFF TRAY
OPEN HYDRAULIC SEAL SITE WELDED HOOK UP CHEMICAL ADDITIVES EXTRACTOR ROLLER CONVEYOR AIR LIFT
ARRESTOR STORAGE TANK
HOOK UP N. TANK

D PISTON VALVE D
FULL BORE BALL FLEXIBLE COUPLING BARREL FOW TEE FLOATING ROOF TANK WITH HEATING SPRAY DRIER BELT CONVEYOR SCALE PARTIAL DRAW-OFF
OPEN DRAIN (FUNNEL) FLANGED HOOK UP SCRUBBER
VALVE STORAGE TANK COIL TRAY
HOOK UP N. WITH SITE WELD

FB

4-WAY BALL VALVE FOOT VALVE RUBBER HOSE DRIP RING WEIGHING VESSEL EVAPORATOR ABSORBENT DRIER MARINE LOADING ARMS
ATMOSPHERIC STORAGE HOOK BELT CONVEYOR CHIMNEY
CLOSED DRAIN SPOOL PIECE WITH
TANK (RECTANGULAR) WITH EMERG
SAFETY RESTRICTION
WELDED FO ORIFICE TACK WELDED
TO FLANGE
SPOOL

3-WAY BALL VALVE CHECKED LEAK OFF SWIVEL JOINT SUMP TANK GAS HOLDER ROTARY FILM DRIER LAUNCHING TRAP WITH FROM/TO UNIT TANK TRUCK INLET HORN
E SPECIAL REDUCING OMEGA ELEMENT FOR FLANGED SPOOL E
VALVE CONCENTRIC REDUCER (DIFFUSION TYPE)
DRIP RING EXPANSION PIECED
COMPENSATION

CHECK VALVE MANUAL CONTROL TEMPORARY STRAINER SPECIAL REDUCING FROM/TO UNIT TANK GAS HOLDER CONTINUOS TUNNEL LAUNCHING TRAP WITH FROM/TO UNIT TANK WAGON CYCLONE
HOSE CONNECTION M
VALVE WITH FLOAT CROSS DRIP RING (DRY) DRIER ECCENTRIC REDUCER

CHECK VALVE ELEMENT CONTROLLED "Y" STRAINER JET SPRAYER ROTARY DRUM DRIER PRODUCTION FROM/TO UNIT TANKER DOLLAR PLATE
VALVE WITH SPRING
F
LOAD SYMBOLS FOR MECHANICAL EQUIPMENT SEPARATOR F

CLASS V
ACTUATORS
SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION

AUTOM. DOWN FLOW BASKET STRAINER SAMPLE CABINET GAS BOOT LAUNCHING TRAP PRODUCTION GAS JACKETED LOADING FROM/TO UNIT PACKED SECTION
HAND ACTUATOR COUNTER WEIGHT VERTICAL VESSEL
CHECK VALVE WITH CONCENTRIC SEPARATOR ARMS
ACTUATOR (GENERAL)
REDUCER

ANGLE CHECK VALVE DIVERTER VALVE INSULATING JOINT COLUMN (GENERIC) LAUNCHING TRAP WEIGHING MACHINE REDISTRIBUTION
SAMPLE CABINET REMOVE HAND CENTRIFUGAL HORIZONTAL VESSEL LIQUID SEPARATOR
FOR SOLIDS WITH ECCENTRIC (LIQUID/LIQUID)
HEATING/COOLING ACTUATOR ACTUATOR (GENERAL)
REDUCER
G G

WAFER CHECK VALVE QUICK OPENING SPECTACLE FLANGE CORROSION COUPON DECANTER ELECTROSTATIC REDISTRIBUTION
FLOAT ACTUATOR PRESSURE VESSEL COLUMN WITH TRAYS
VALVE (GAS,LIQUID
CI
MONITORING PROBE WITH BOOT (ONE SECTION) SEPARATOR COMPLEMENTARY SYMBOLS INJECTION)

FOR EQUIPMENT
SYMBOL DESCRIPTION SYMBOL DESCRIPTION

BREATHING VALVE ELECTRICAL RESISTANCE SAMPLE POINT COLUMN WITH TRAYS CLARIFIER FLOTATION CELLS INTERNAL COIL TRAYS FOR COLUMNS BAFFLE WITH
DIAPHRAGM VALVE JACKETED PRESSURE
(TWO SECTIONS) WITH TWO PASSES PARTITION PLATE
ER SP SYMBOLS FOR STATUS VESSEL
TYPE
H INDICATION H

SYMBOL DESCRIPTION SYMBOL DESCRIPTION

PINCH VALVE LOCK GATE COLUMN WITH TRAYS THICKENER LONGITUDINAL EXTERNAL COIL TRAYS FOR COLUMNS
CORROSION PROBE GLOBE VALVE NORMALLY VESSEL WITH MIXER
GATE VALVE LOCKED SEPARATOR FOR WASTE
OR (LOCKED) OPEN (THREE SECTIONS) WITH DUAL FLOW
CW OPEN

LO LO
VORTEX BREAKER

CHOKE VALVE SEDIMENTATION TANK GRID COLLECTOR OIL JACKET


BUTTERFLY VALVE GLOBE (LOCKED) OR VESSEL WITH COLUMN WITH FLANGED NOZZLE
GATE VALVE NORMALLY
EQUIPMENT OPEN NORMALLY CLOSED HEATING COIL CHIMNEY TRAYS SKIMMER (COMPANION FLANGE
BY AGIP)
NON IDENTIFIED
L L
LC
SYMBOL DESCRIPTION SYMBOL DESCRIPTION

GATE VALVE DOUBLE BLOCK AND A = CAP SOCKET WELD ECCENTRIC REDUCER CYLINDER ROTATING DISC OPEN SETTLING TANK OIL SKIMMER ELECTRICAL HEATING FLANGED NOZZLE
GATE (LOCKED) OR BUTTERFLY VALVE
BLEED VALVE OPEN B = CAP THREADED NORMALLY CLOSED (GENERIC-NOT FOR COLUMN (COMPANION FLANGE
LOCKED OPEN
A/B FIREFIGHTING
BY SUPPLIER)
SYSTEM)

LO
LC

ANGLE GATE VALVE DOUBLE BLOCK AND FLANGE WITH LENS AUTOCLAVE SECTIONED TOWER GUN BARREL VAPOUR OR GAS HOPPER VIBRATOR BY SUPPLIER)
RING SPACER BALL VALVE LOCKED BUTTERFLY VALVE
BLEED CLOSE PACKING OPEN SEPARATOR
NORMALLY OPEN

LO
M M

FULL BORE GATE FROM/TO UNIT WELDED CAP DAMPER PACKING COLUMN SCRUBBER MOISTURE FROM/TO UNIT VIBRATING HEAD FRONT FLANGED
SINGLE BLIND BALL VALVE NORMALLY BUTTERFLY NORMALLY
VALVE SEPARATOR NOZZLE
OPEN OR (LOCKED) CLOSED
(COMPANION FLANGE
BY AGIP)

LC

EX-DE 01 09/08/19 Issue For HAZOP (IFH) P. Martinez J.Dominguez A.Loza G.Vallerga R.Milani
FROM/TO UNIT GAS KNOCK OUT DRUM FROM/TO UNIT FRONT FLANGED EX-DE 00 29/05/19 Issue For Comments (IFC) O.Nava J.Dominguez A.Loza G.Vallerga R.Milani
NEEDLE VALVE MALE PLUG FLANGE WITH LENS BALL (LOCKED) OR GAS MEMBRANE REGENERATOR MIST ELIMINATOR
PLUG VALVE Validity Revision
NORMALLY CLOSED DAMPER NOZZLE
PACKING AND Status Number Contractor Contractor Contractor Company Company
NORMALLY OPEN Date Description
INSTRUMENT (COMPANION FLANGE Prepared Verified Approved Checked Approved
Index Revision
CONNECTION BY SUPPLIER)
Company Logo and Business Name Project Name Company Document ID:
LC
Mexico Area 1 –
N 6006C2DPFM07414 N
DRAWING NUMBER:
Development Project
GAS PRESSURIZER MDEA ABSORBER TEST SEPARATOR FROM/TO UNIT COLUMN TOP VAPOURS CORNER FLANGED
UNION QUICK CONNECTION GLOBE VALVE LOCKED NEEDLE VALVE Eni Mexico Job N.
COUPLING OPEN OUTLET NOZZLE
NORMALLY OPEN Contractor Logo and Business Name Contractor Document ID:
(COMPANION FLANGE
BY AGIP)
J. Ray McDermott de México S.A de C.V.
LO
Contractor N. 5000015145-A8156
Facility and Sub Facility Name Scale Sheet of Sheets
BLIND FLANGE CATALYSTIC REACTOR TEST GAS SEPARATOR SEPARATOR TRAYS FOR COLUMNS CORNER FLANGED
INSULATING FLANGE BALL (LOCKED) OR BALL NORMALLY OR MEMBRANE GAS
OR GENERAL WITH DOWNCOMER NOZZLE
NORMALLY CLOSED (LOCKED) OPEN PRESSURIZER n.a. 3/18
FB FB MEXICO AREA 1- AMOCA WHP1
FULL BORE FULL BORE (REACTOR) (COMPANION FLANGE
BY SUPPLIER) Document Title Superseeded N. 6006C2BPFM02135 Sh.03
WELLHEAD PLATFORM
P LC LO Superseeded by N.CPY P
PIPING & INSTRUMENTATION DIAGRAM Plant Area Unit

SYMBOLS n.a. n.a.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

This document is property of eni ghana exploration and production ltd. It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent. Software: Autocad File Name:6006C2DPFM07414_03.dwg
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

CONTROL VALVES, DAMPERS MANUAL STATIONS RELEVANT REFERENCE DRAWINGS


SELF ACTUATED LEVEL VALVES
AND FIREDAMPERS FOR SAFETY NUMBER TITLE
A SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION A

2019.COO.GEN.SDS ITEM NUMBERING COMPANY SPECIFICATION


TV
DAMPER WITH CILINDRIC BSV FIRE DAMPER WITH CILINDRIC SELF ACTUATED LEVEL CONTROL SELA ACTUATED LEVEL CONTROL ABANDONMENT SHUT DOWN PROCESS SHUT DOWN MANUAL
024
001 ACTUATOR ACTUATOR COMPLETE WITH LIMIT VALVE WITH MECHANICAL LINKAGE LCV VALVE WITH MECHANICAL LINKAGE STATION
T 002 ASD
MANUAL STATION PSD
LCV
ZSH
003
SWITCHES ON CLOSE AND OPEN 001 A OUTSIDE TANK HS
TANK
(FLOAT INSIDE VESSEL) HS
N 044
ZSL
003
POSITION,FAIL CLOSED 040
K

RED ESD MANUAL STATION FIRE ALARM MANUAL STATION


MFA

ACTUATORS SELF ACTUATED PRESSURE VALVES HS


RED
HS
045
041

SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION


B B

DIAPHRAGM,SPRING OPPOSED OR ROTARY MOTOR ELECTRICAL TYPE SELF ACTUATED PRESSURE TYPICAL PRESSURE REDUCING YELLOW ESD MANUAL STATION MAN OVERBOARD ALARM MANUAL
UNSPECIFIED ACTUATOR WITH HANDWHEEL REDUCING CONTROL VALVE,SELF FILTER FOR GAS MOB STATION
M PCV YEL
001 CONTAINED WITH HANDWHEEL HS
HS
ADJUSTABLE SET POINT 046
042

ALTERNATIVE 1: SOLENOID SELF ACTUATED PRESSURE TYPICAL PRESSURE REDUCING BLU ESD MANUAL STATION FUSIBLE PLUG NETWORK DEPRESS.
S SPRING/DIAPHRAGM WITH OR PCV
FILTER FOR AIR HDV HAND VALVE
002
REDUCING CONTROL VALVE WITH
WITHOUT POSITIONER AND S
BLU
EXTERNAL PRESSURE TAP HS
SOLENOID VALVE THAT HS 047
PRESSIRIZES DIAPHRAGM WHEN 043

ACTUATED

C C
ALTERNATIVE 2: AS ABOVE. ELECTROHYDRAULIC SELF ACTUATED DIFFERENTIAL TYPICAL PRESSURE REDUCING
S
THE POSITION TAGGING "ZC"
E
PCV
003
PRESSURE REDUCING CONTROL FILTER FOR LUBRIFICATION AIR MANUAL STATIONS RELEVANT
NEED NOT BE USED EVEN IF THE M WITH INTERNAL AND EXTERNAL
POSITION IS SHOWN PRESSURE TAP
FOR SAFETY
SYMBOL DESCRIPTION SYMBOL DESCRIPTION

DIAPHRAGM/PRESSURE BALANCED DIGITAL SELF ACTUATED BACKPRESSURE SELF ACTUATED PRESSURE FLASHING BLU LIGHT GREEN BEACON
CONTROL VALVE SELF CONTAINED REDUCING CONTROL VALVE WITH
PCV FBL FGB
D 004
PCV
INTEGRAL OUTLET PRESSURE
PI
007 UL UL
RELIEF VALVE AND PRESSURE
050 053
INDICATOR (TYPICAL AIR SET)

D CYLINDER SPRING OPPOSED HAND ACTUATOR OR HANDWHEEL SELF ACTUATED BACKPRESSURE FLASHIN RED LIGHT OPTICAL PRISMATIC LIGHT D
SNGLE ACTION FOR LINEAR STEM
CONTROL VALVE WITH EXTERNAL FRL
OR UNSPECIFIED MOTION PCV OPL
005 PRESSURE TAP UL
UL
051
054

CYLINDER SPRING OPPOSED LATCH-TYPE ACTUATOR WITH RED BEACON


SNGLE ACTION FOR LINEAR STEM
MANUAL RESET FRB
OR UNSPECIFIED MOTION AND
WITH HANDWHEEL
S SAFETY VALVES UL

052

R
SYMBOL DESCRIPTION SYMBOL DESCRIPTION

CYLINDER DOUBLE ACTION FOR LATCH-TYPE ACTUATOR WITH PRESSURE RELIEF OR SAFETY PILOT OPERATED RELIEF VALVE
E PSV E
LINEAR STEM OR UNSPECIFIED REMOTE RESET 001 VALVE PSV
P 005
MOTION S

CYLINDER SPRING OPPOSED SELFACTUATED PRESSURE VACUUM RELIEF VALVE REPTURE DISK OR SAFETY HEAD
PSV
SINGLE ACTION FOR ROTARY STEM REDUCER WITH HANDWHEEL 002 PSE
FOR PRESSURE RELIEF
001

AND WITH EXTERNAL PRESSURE


TAP

CYLINDER SPRING OPPOSED SELFACTUATED PRESSURE PRESSURE RELIEF OR SAFETY REPTURE DISK OR SAFETY HEAD
SINGLE ACTION FOR ROTARY STEM REDUCER PSV VALVE SPRING OR WEIGHT LOADED
F 003
PSE FOR VACUUM RELIEF F
AND WITH HANDWHEEL WITH EXTERNAL PRESSURE TAP 002

CYLINDER DOUBLE ACTION FOR SELFACTUATED PRESSURE PRESSURE AND VACUUM RELIEF
PSV
RATORY STEM REDUCER 004 VALVE SPRING OR WEIGHT LOADED
WITH INTERNAL PRESSURE TAP OR WITH INTEGRAL PILOT

VACUUM PRESSION

ROTARY MOTOR PNEUMATIC TYPE SELFACTUATED DIFFERENTIAL

G
M PRESSURE REDUCER WITH
SELF ACTUATED VALVES G
INTERNAL AND EXTERNAL
PRESSURE TAP
TEMPERATURE AND FUSIBLE PLUGS
SYMBOL DESCRIPTION SYMBOL DESCRIPTION

ROTARY MOTOR ELECTRICAL TYPE SELF ACTUATED TEMPERATURE FUSIBLE PLUG OR DISK
CONTROL VALVE,FILLED SYSTEM TSE
M TCV 001
001 TYPE
TANK

ACTUATORS IN EVENT OF
SAFETY DETECTORS
H
POWER FAILURE H

SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION

TWO-WAY VALVE,FAIL OPEN


THREE-WAY VALVE,FAIL OPEN TO
Alternative 1
FO
(ALTERNATIVE 1 IS SUGGESTED)
PATH "A-C" AND SIDE "B" OF
A B

FLUID INLET CLOSED


C
Alternative 2

TWO-WAY VALVE,FAIL CLOSED ANY VALVE,FAIL LOCKED


FC (ALTERNATIVE 1 IS SUGGESTED) POSITION DOES NOT CHANGE)
Alternative 1 FL

Alternative 1
(ALTERNATIVE 1 IS SUGGESTED)

L L
Alternative 2
Alternative 2

THREE-WAY VALVE,SIDE OF BLACK ANY VALVE,FAIL INDETERMINATE


SHOWN FAIL OPEN AND SIDE OF FI (ALTERNATIVE 1 IS SUGGESTED)
Alternative 1
FLUID INLET CLOSED

Alternative 2

SELF ACTUATED FLOW


RATE VALVES
M M

SYMBOL DESCRIPTION SYMBOL DESCRIPTION

SELF ACTUATED FLOW RATE SELF ACTUATED FLOW RATE


CONTROL VALVE WITH INTEGRAL CONTROL VALVE WITHOUT

FLOW INDICATION INDICATION


FCV
FICV
002
001

EX-DE 01 09/08/19 Issue For HAZOP (IFH) P. Martinez J.Dominguez A.Loza G.Vallerga R.Milani
EX-DE 00 29/05/19 Issue For Comments (IFC) O.Nava J.Dominguez A.Loza G.Vallerga R.Milani
Validity Revision
Status Number Contractor Contractor Contractor Company Company
Date Description
Prepared Verified Approved Checked Approved
Index Revision
ACTUATED HAND VALVES Company Logo and Business Name Project Name Company Document ID:

Mexico Area 1 –
N 6006C2DPFM07414 N
DRAWING NUMBER:
Development Project
SYMBOL DESCRIPTION SYMBOL DESCRIPTION
Eni Mexico Job N.

HAND CONTROL VALVE IN HAND CONTROL VALVE IN SIREN


Contractor Logo and Business Name Contractor Document ID:
HV
PROCESS LINE 003
PNEUMATIC SIGNAL LINE SX
HV
001

J. Ray McDermott de México S.A de C.V.


Contractor N. 5000015145-A8156
Facility and Sub Facility Name Scale Sheet of Sheets

n.a. 4/18
HAND ACTUATED ON-OFF MEXICO AREA 1- AMOCA WHP1
SWITCHING VALVE IN PNEUMATIC
Document Title Superseeded N. 6006C2BPFM02135 Sh.04
SIGNAL LINE
HS WELLHEAD PLATFORM
P 002 Superseeded by N.CPY P
PIPING & INSTRUMENTATION DIAGRAM Plant Area Unit

SYMBOLS n.a. n.a.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

This document is property of eni ghana exploration and production ltd. It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent. Software: Autocad File Name:6006C2DPFM07414_04.dwg
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

REFERENCE DRAWINGS

EQUIPMENT E EQUIPMENT S MICELLANEOUS NUMBER TITLE


A A
SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION 20198.COO.GEN.SDS ITEM NUMBERING COMPANY SPECIFICATION

ELECTRIC GENERATOR ELECTRIC MOTOR INERGEN CYLINDER DELUGE VALVE FREE STANDING TIE-IN
SIAMESE FIRE DEPT.
CONNECTION TIE-IN
G M CA TXX

CARBON DIOXIDE PRE-ACTION VALVE SINGLE FIRE DPT. SLOPE


CYLINDER CONNECTION

1:200
CO2

B B

POWDER CYLINDER WATER/FOAM LIQUID VALVE IN PIT SPECIAL PART


NIPPLED UP HEDDS

XX
P
NNN

NITROGEN CYLINDER SELFPRIMING LINE HOSE REEL


PREMIXER

C C

FIXED FIREFIGHTING MIXER FOR PREMIXER POWDER//FOAM GOSE


POWDER TANK FOAM PROPORTIONER REEL

PREMIXER FOAM FIXED MEDIUM DRY CHEMICAL REEL


VESSEL EXPANSION FOAM
NOZZLE

D D
MECHANICAL LEVEL FIXED LOW EXPANSION FOAM REEL
FOR CYLINDER FOAM NOZZLE
OPENING

SPRINKLERS NOZZLE AND FOAM CARBON DIOXIDE


(WATER-FOAM) CHAMBER FOR FIXED REAL STATION
FTF ROOF TANKS

WATER DELUGE NOZZLE NOZZLE AND FOAM SPRINKLERS


E E
SHEDDER FOR
XTF FLOATING ROOF TANKS

INERGEN NOZZLE FOAM MONITOR NOZZLE FOAM CHAMBER

DRY CHEMICAL WATER MONITOR FOAM POURER


NOZZLE NOZZLE
F F

CO2 NOZZLE WHEELED FOAM HIGH EXPANSION FOAM


MONITOR GENERATOR

UPRIGHT SPRINKLER WHEELED WATER


HEDDS MONITOR
G G

PENDENT SPRINKLERS FIRE PLUG WITH


HEDDS SERVICE WATER
PLUG

UPRIGHT SPRINKLER FIRE PLUG-UNI 45


NIPPLED UP HEDDS CASING GROOVE

H H

PENDENT SPRINKLERS WALL HYDRANT WITH


NIPPLED UP HEDDS FLEXIBLE HOSE AND
NOZZLE

SPRINKLERS WITH COMBINED HYDRANT/


GUARD HEDDS MONITOR NOZZLE

L L

SIDEWALL SPRINKLER HYDRANT,ONE HOSE


HEDDS OUTLET

OUTSIDE SPRINKLER HYDRANT,TWO HOSE


HEDDS OUTLETS

M M

SPECIAL SPRAY HYDRANT,TWO HOSE


NOZZLE HEDDS OUTLETS AND PUMPER
CONNECTION

EX-DE 01 09/08/19 Issue For HAZOP (IFH) P. Martinez J.Dominguez A.Loza G.Vallerga R.Milani
EX-DE 00 29/05/19 Issue For Comments (IFC) O.Nava J.Dominguez A.Loza G.Vallerga R.Milani
ALARM CHECK VALVE WALL HYDRANT,TWO
Validity Revision
HOSE OUTLETS Number Contractor Contractor Contractor Company Company
Status Description
Date
Prepared Verified Approved Checked Approved
Index Revision

Company Logo and Business Name Project Name Company Document ID:

Mexico Area 1 –
N 6006C2DPFM07414 N
DRAWING NUMBER:
Development Project
DRY PIPE VALVE HOUSED HYDRANT,TWO Eni Mexico Job N.
HOSE OUTLETS
Contractor Logo and Business Name Contractor Document ID:

J. Ray McDermott de México S.A de C.V.


Contractor N. 5000015145-A8156
Facility and Sub Facility Name Scale Sheet of Sheets
DRY PIPE VALVE WITH SIAMESE FIRE DEPT.
QUICK OPENING CONNECTION n.a. 5/18
MEXICO AREA 1- AMOCA WHP1
DEVICE
Document Title Superseeded N. 6006C2BPFM02135 Sh.05
WELLHEAD PLATFORM
P Superseeded by N.CPY P
PIPING & INSTRUMENTATION DIAGRAM Plant Area Unit

SYMBOLS n.a. n.a.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

This document is property of eni ghana exploration and production ltd. It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent. Software: Autocad File Name:6006C2DPFM07414_05.dwg
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

SIGNAL LINES MISCELLANEOUS FLOW INSTRUMENTS RELIEF DEVICES GENERAL INSTRUMENTATION TYPICAL DETAILS
REFERENCE DRAWINGS

NUMBER TITLE
A A

I 20198.COO.GEN.SDS ITEM NUMBERING


P SET PRESSURE
AAAAA MAGNETIC AAAAA
0.0 bar g
I/P TRANSDUCER 06215.DOC.GEN.SDS FACILITY FUNCITIONAL UNITS
NNN A AUXILIARY LOCATION PILOT LIGHT
NNN A
CONNECT TO PROCESS PSV

P NNN A
I
PROPELLER / TURBINE
AAAAA PRESSURE RELIEF VALVE
P/I TRANSDUCER
PNEUMATIC SIGNAL NNN A WITH TYPICAL LABEL IA INSTRUMENT AIR SUPPLY

N" A N"
POSITIVE DISPLACEMENT
SET PRESSURE
AAAAA
ELECTRICAL SIGNAL SUM 0.0 bar g AS AIR SUPPLY
B NNN A B

TARGET PSV

NNN A DIAPHRAGM SEAL


SOFTWARE SERIAL / LINK AAAAA H
HIGH ALARM VACUUM RELIEF VALVE
NNN A
ULTRASONIC LOCAL CONTROL
INSTRUMENT CAPILLARY PANEL LOCAL CONTROL PANEL
HH 010000JPNNN
TUBING
AAAAA
HIGH HIGH ALARM
VARIABLE AREA
NNN A BURST PRESSURE
0.0 bar g
HYDRAULIC SIGNAL
ORIFICES ACTUATORS
PSE
AAAAA RELIEF RUPTURE DISC
C LOW ALARM VORTEX C
NNN A
NNN A FOR PRESSURE
ELECTROMAGNETIC OR L

SONIC SIGNAL FE

AAAAA NNN A
CORIOLIS TYPE
LOW LOW ALARM DIAPHRAGM
NNN A MASS FLOWMETER BURST PRESSURE
CORIOLIS
LL 0.0 bar g ORIFICE PLATE WITH QUICK CHANGE FITTING

PSE
RATIO RELIEF RUPTURE DISC
FE
AAAAA PITOT NNN A FOR VACUUM
RATIO FUNCTION DIAPHRAGM (PRESSURE BALANCED)
NNN A
NNN A

D IGNITOR SET PRESSURE ORIFICE PLATE D

0.0 bar g
THERMAL MASS FLOW DOUBLE OR SINGLE ACTING CYLINDER
FO

THERMAL PSV NNN A


FG
FLOW SIGHT GLASS NNN A
NNN A M
BUCKLING PIN
AVERAGING PITOT RESTRICTION ORIFICE
RELIEF VALVE MOTOR (ELECTRIC)
(ANNUBAR)

FE
V-CONE NNN A
SET PRESSURE MANUAL
+0.0 mbar g
E -0.0 mbar g VENTURI TUBE E
GENERAL INSTRUMENTATION CONTROL VALVES SPRING
PVSV
FE
NNN A
NNN A
PRESSURE AND VACUUM
CONTROL VALVE WITH
MEASURED VARIABLE AND FUNCTION RELIEF VALVE SPRING
3-WAY GATE VALVE HAND WHEEL
LOADED V-CONE
AAAAA VACUUM PRESSURE

NNN A

SEQUENCE NUMBER AND SUFFIX


CHOKE VALVE
IDENTIFICATION LETTERS FUNCTIONS SOLENOID VALVES
AAAAA
F F
GENERIC INSTRUMENT FIELD MOUNTED
NNN A S

FIRST LETTER SECOND LETTERS


2-WAY VALVE
AAAAA GENERIC INSTRUMENT IN PRIMARY LOCATION
NNN A (CONTROL CENTRE) NORMALLY ACCESSIBLE BY OPERATOR MEASURED OR READOUT OR
GATE VALVE MODIFIER OUT FUNCTION MODIFIER
INITIATING VARIABLE PASSIVE FUNCTION S

AAAAA
INSTRUMENT OR FUNCTION NORMALLY INACCESSIBLE OR BEHIND R
THE PANEL DEVICE ON PRIMARY LOCATION SOLENOID WITH MANUAL RESET
NNN A A ANALYSIS ALARM
(CONTROL CENTRE) BALL VALVE
(REDUCED BORE)
AAAAA BURNER,COMBUSTION,FLAME
GENERIC INSTRUMENT IN AUXILIARY LOCATION (UCP) NORMALLY B USER'S CHOICE USER'S CHOICE USER'S CHOICE S
NNN A ACCESSIBLE BY OPERATOR 3-WAY VALVE
G G

CORROSION FLOW DIRECTION WHEN


BALL VALVE C CONTROL
AAAAA DE-ENERGISED
INSTRUMENT OR FUNCTION NORMALLY INACCESSIBLE OR BEHIND (FULL BORE)
FB
NNN A THE PANEL DEVICE AUXILIARY LOCATION (UCP)
D DENSITY DIFFERENTIAL DETECTOR

E SENSORY
AAAAA VOLTAGE DISCREPANCE
GLOBE VALVE (PRIMARY ELEMENT) S
SHARED DISPLAY/SHARED CONTROL
NNN A
F FLOW RATE RATIO (FRACTION) 4-WAY VALVE
FLOW DIRECTION WHEN
AAAAA SHARED DISPLAY, SHARED CONTROL PRIMARY LOCATION GAS CONCENTRATION DE-ENERGISED
BUTTERFLY VALVE G GLASS, VIEWING DEVICE
NNN A NORMALLY ACCESSIBLE BY OPERATOR (CONTROL CENTRE) (INCLUDING H2S)
H H
H HAND HIGH
AAAAA SHARED DISPLAY, SHARED CONTROL PRIMARY LOCATION NORMALLY
INTERLOCK LOGIC
NNN A INACCESSIBLE BY OPERATOR (CONTROL CENTRE). CURRENT (ELECTRICAL) INDICATE
DIAPHRAGM VALVE I

LSD
AAAAA J POWER SCAN
SHARED DISPLAY/CONTROL IN AUXILIARY LOCATION (UCP) NORMALLY
I LSD WITH PNEUMATIC LOGIC
NNN A INACCESSIBLE BY OPERATOR.
TIME RATE OF
PLUG VALVE K TIME, TIME SCHEDULE CONTROL STATION
CHANGE
AAAAA SHARED DISPLAY/CONTROL IN AUXILIARY LOCATION (UCP) NORMALLY PSD

ACCESSIBLE BY OPERATOR L LEVEL LIGHT LOW


NNN A I PSD WITH PNEUMATIC LOGIC
L DELUGE VALVE L
LOGIC CONTROL IN AUXILIARY LOCATION (UCP) MIDDLE,
M MOISTURE / MOTOR MOMENTARY
I
("I" IS THE CONTROL LOGIC SEQUENCE IN VENDOR UCP AND "IZ" INTERMEDIATE
NNN
ESD
IS THE EMERGENCY OR PROCESS SHUTDOWN INTERLOCK
N USER'S CHOICE USER'S CHOICE USER'S CHOICE USER'S CHOICE ESD WITH PNEUMATIC LOGIC
IN VENDOR SHUTDOWN PLC). I
PRESSURE REGULATORS
I LOGIC CONTROL IN PRIMARY LOCATION
O ORIFICE, RESTRICTION
("I" IS THE CONTROL LOGIC SEQUENCE IN DCS AND "IZ" IS THE
NNN
EMERGENCY OR PROCESS SHUTDOWN INTERLOCK IN ESD.
P PRESSURE, VACUUM POINT(TEST) CONNECTION EMERGENCY SHUT-DOWN SYSTEM

TWO WAY FILLED


AAAAA COMPUTER FUNCTION NORMALLY ACCESSIBLE BY OPERATOR IN
INTEGRATED,
NNN A PRIMARY LOCATION (CONTROL CENTRE) Q QUANTITY PARTIAL STROKE TEST ESD
TOTALIZE I
M M
EMERGENCY SHUT-DOWN
R RADIATION RECORD
AAAAA
COMPUTER FUNCTION NORMALLY INACCESSIBLE
NNN A IN PRIMARY LOCATION (CONTROL CENTRE)
S SPEED, FREQUENCY, SMOKE SAFETY SWITCH PSD
THREE WAY FILLED I
PROCESS SHUT-DOWN
AAAAA COMPUTER FUNCTION NORMALLY INACCESSIBLE T TEMPERATURE TRANSMIT
NNN A IN AUXILIARY LOCATION (UCP) EX-DE 01 09/08/19 Issue For HAZOP (IFH) P. Martinez J.Dominguez A.Loza G.Vallerga R.Milani
EX-DE 00 29/05/19 Issue For Comments (IFC) O.Nava J.Dominguez A.Loza G.Vallerga R.Milani
F&G
I Validity Revision
LOGIC CONTROL NORMALLY INACCESSIBLE OR BEHIND U MULTIVARIABLE MULTIFUNCTION MULTIFUNCTION MULTIFUNCTION / UCP Contractor Contractor Contractor Company Company
Status Number Description
Date
THE PANEL DEVICE IN PRIMARY LOCATION (CONTROL CENTRE) F&G/ESD SYSTEM INTERLOCK Prepared Verified Approved Checked Approved
I PRESSURE WITH Index Revision
("I" IS THE CONTROL LOGIC SEQUENCE IN VENDOR UCP AND "IZ" IS THE VIBRATION
NNN EXTERNAL TAP V VALVE, DAMPER, LOUVRE Company Logo and Business Name Project Name Company Document ID:
MECHANICAL ANALYSIS
EMERGENCY OR PROCESS SHUTDOWN INTERLOCK IN
Mexico Area 1 –
N PCS 6006C2DPFM07414 N
VENDOR SHUTDOWN PLC). DRAWING NUMBER:
Development Project
I
DIFFERENTIAL PRESSURE W WEIGHT, FORCE WELL
CONTROL SYSTEM INTERLOCK Eni Mexico Job N.

LOGIC CONTROL NORMALLY INACCESSIBLE OR BEHIND REDUCING REGULATOR Contractor Logo and Business Name Contractor Document ID:
IZ DANGER, SAFETY, EMERGENCY,
THE PANEL DEVICE IN AUXILIARY LOCATION (UCP) ("I" IS THE LOGIC X X AXIS FAUL / SENSORY PIG UNCLASSIFIED PULSATION
NNN ON-OFF VALVE
SEQUENCE OR IN VENDOR UCP AND "IZ" IS THE EMERGENCY OR LSO J. Ray McDermott de México S.A de C.V.
PROCESS SHUTDOWN IN INTERLOCK VENDOR SHUTDOWN PLC). SELF CONTAINED EVENT,STATE OR I
Contractor N. 5000015145-A8156
Y Y AXIS RELAY, COMPUTE, CONVERT
BACK PRESSURE PRESENCE, SIREN BEACON LOCAL SHUT-DOWN Facility and Sub Facility Name Scale Sheet of Sheets

REGULATOR
n.a. 6/18
Z POSITION, DIMENSION Z AXIS POSITION MEXICO AREA 1- AMOCA WHP1
UCP Document Title Superseeded N. 6006C2BPFM02135 Sh.06
I WELLHEAD PLATFORM
SELF CONTAINED
P Superseeded by N.CPY P
PRESSURE REGULATOR UCP INTERLOCK
PIPING & INSTRUMENTATION DIAGRAM Plant Area Unit

SYMBOLS n.a. n.a.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

This document is property of eni ghana exploration and production ltd. It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent. Software: Autocad File Name:6006C2DPFM07414_06.dwg
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

REFERENCE DRAWINGS
TYPICAL 1
NUMBER TITLE
SDV WITH SPRING RETURN ACTUATOR
A A

20198.COO.GEN.SDS ITEM NUMBERING


EXPANDED DETAILS P&ID REPRESENTATION
06215.DOC.GEN.SDS FACILITY FUNCTIONAL UNITS

NOTE 1
DISCREPANCY RESET/OPEN CLOSE

ZLH ZLL UAD HSO HSC

GENERAL NOTES:

A.VALVE TYPE TO BE IN ACCORDANCE TO PROJECT PIPING CLASS.

B B

ESD
IZ

PCS ESD TYP. 1


I IZ

NOTES:
SDV
LOCAL RESET
1. ALARM RESET FUNCTION FOR HMI PURPOSE ONLY.
C SDY SDY HS 2. PARTIAL STROKE TEST DEVICE SHALL BE INTEGRATED WITH ACTUATOR VALVE C

A B L IA 3. THE SAME TYPICAL IS VALID FOR FULL BORE VALVE

FB
LOCAL CONTROL PANEL FC

ZSH ZSL

SDV

D D

FB
FC

TYPICAL 2
SDV WITH SPRING RETURN ACTUATOR AND PARTIAL STROKE TESTING

EXPANDED DETAILS P&ID REPRESENTATION

E E
PST PST NOTE 1

RESULT INITIATION DISCREPANCY RESET/OPEN CLOSE

UAQ HSQ ZLH ZLL UAD HSO HSC

ESD
IZ

F PCS ESD TYP. 2 F


I IZ
AMS

SDV
LOCAL RESET

PARTIAL
SDY SDY HS
STROKE IA
A B L
TEST
DEVICE
FB
G NOTE 2 G
LOCAL CONTROL PANEL FC

ZSH ZSL ZT

SDV

H FB H
FC

TYPICAL 3
ON - OFF VALVE (PCS CONTROL) (NOTE 3)

EXPANDED DETAILS P&ID REPRESENTATION

L
DISCREPANCY OPEN CLOSE L

ZLH ZLL UAD HSO HSC

PCS
I

PCS TYP. 3
I

M M

UV

EX-DE 01 09/08/19 Issue For HAZOP (IFH) P.Martinez J.Dominguez A.Loza G.Vallerga R.Milani
UY
EX-DE 00 29/05/19 Issue For Comments (IFC) O.Nava J.Dominguez A.Loza G.Vallerga R.Milani
IA Validity Revision
Status Number Contractor Contractor Contractor Company Company
Date Description
Prepared Verified Approved Checked Approved
Index Revision

Company Logo and Business Name Project Name Company Document ID:
LOCAL CONTROL PANEL
Mexico Area 1 –
N 6006C2DPFM07414 N
DRAWING NUMBER:
Development Project
Eni Mexico Job N.

ZSH ZSL Contractor Logo and Business Name Contractor Document ID:

UV J. Ray McDermott de México S.A de C.V.


Contractor N. 5000015145-A8156
Facility and Sub Facility Name Scale Sheet of Sheets

n.a. 7/18
MEXICO AREA 1- AMOCA WHP1

Document Title Superseeded N. 6006C2BPFM02135 Sh.07


WELLHEAD PLATFORM
P Superseeded by N.CPY P
PIPING & INSTRUMENTATION DIAGRAM Plant Area Unit

SYMBOLS n.a. n.a.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

This document is property of eni ghana exploration and production ltd. It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent. Software: Autocad File Name:6006C2DPFM07414_07.dwg
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

TYPICAL 4 REFERENCE DRAWINGS


BDV WITH SINGLE ACTION ACTUATOR
NUMBER TITLE
A A
EXPANDED DETAILS P&ID REPRESENTATION 06215.COO.GEN.SDS FACILITY FUNCTIONAL UNITS

DISCREPANCY
RESET
ZLH ZLL UAD
HSR

GENERAL NOTES:

A.VALVE TYPE TO BE IN ACCORDANCE TO PROJECT PIPING CLASS.

B PAL B
ESD
IZ

DCS ESD
I TYP. 4
IZ

PT

BDV
NOTES:
1. VOLUME TANK SHALL BE NUMBERED 014600-VA-NNNNN.
BDY BDY
C IA C
A B

FO

LOCAL CONTROL PANEL FB

ZSH ZSL PI
NOTE PSV
L
1
BDV

D D

FO
FB

TYPICAL 5
ELECTRIC MOTOR OPERATED VALVE (HARDWIRED TO PCS)

EXPANDED DETAILS P&ID REPRESENTATION

E
STOP OPEN OPEN FAILURE E
HSZ HSO UAL UAX ZI VALVE

POSITION
CLOSE CLOSE
INDICATOR

PCS
I

TYP. 5
F F
PCS
I

MOV

G G

ZSH ZSL

MOV

H H

TYPICAL 6
ELECTRIC MOTOR OPERATED VALVE (FIELDBUS)

EXPANDED DETAILS P&ID REPRESENTATION

STOP OPEN OPEN FAILURE


HSZ HSO UAL UAX ZI VALVE

POSITION
L L
CLOSE CLOSE
INDICATOR

PCS
I

TYP. 6

PCS
M
I M

MOV

EX-DE 01 09/08/19 Issue For HAZOP (IFH) P.Martinez J.Dominguez A.Loza G.Vallerga R.Milani
EX-DE 00 29/05/19 Issue For Comments (IFC) O.Nava J.Dominguez A.Loza G.Vallerga R.Milani
Validity Revision
Status Number Contractor Contractor Contractor Company Company
Date Description
Prepared Verified Approved Checked Approved
Index Revision

Company Logo and Business Name Project Name Company Document ID:

Mexico Area 1 –
N 6006C2DPFM07414 N
DRAWING NUMBER:
Development Project
Eni Mexico Job N.
ZSH ZSL
Contractor Logo and Business Name Contractor Document ID:

MOV J. Ray McDermott de México S.A de C.V.


Contractor N. 5000015145-A8156
M Facility and Sub Facility Name Scale Sheet of Sheets

n.a. 8/18
MEXICO AREA 1- AMOCA WHP1

Document Title Superseeded N. 6006C2BPFM02135 Sh.08


WELLHEAD PLATFORM
P Superseeded by N.CPY P
PIPING & INSTRUMENTATION DIAGRAM Plant Area Unit

SYMBOLS n.a. n.a.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

This document is property of eni ghana exploration and production ltd. It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent. Software: Autocad File Name: 6006C2DPFM07414_08.dwg
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

TYPICAL 7 REFERENCE DRAWINGS

SDV WITH SPRING RETURN ACTUATOR (UCP CONTROL)


NUMBER TITLE
A A

20198.COO.GEN.SDS ITEM NUMBERING


EXPANDED DETAILS P&ID REPRESENTATION

06215.COO.GEN.SDS FACILITY FUNCTIONAL UNITS


NOTE 1
DISCREPANCY RESET/OPEN CLOSE

ZLHU ZLLU UADU HSOU HSCU

GENERAL NOTES:

A.VALVE TYPE TO BE IN ACCORDANCE TO PROJECT PIPING CLASS.

B B

UCP - ESD
IZ

UCP UCP - ESD TYP. 7


I IZ

SDV NOTES:
LOCAL RESET
1. ALARM RESET FUNCTION FOR HMI PORPUSE ONLY.
SDY SDY HS 2. PARTIAL STROKE TEST DEVICE SHALL BE INTEGRATED WITH ACTUADOR VALVE.
C C
A B L IA 3. THE SAME TYPICAL IS VALID FOR FULL BORE VALVE.

FB
LOCAL CONTROL PANEL FC

ZSH ZSL

SDV

D D

FB
FC

TYPICAL 8
SDV WITH SPRING RETURN ACTUATOR AND PARTIAL STROKE TESTING (UCP CONTROL)

EXPANDED DETAILS P&ID REPRESENTATION

E E
PST PST NOTE 1

RESULT INITIATION DISCREPANCY RESET/OPEN CLOSE

UAQU HSQU ZLHU ZLLU UADU HSOU HSCU

UCP - ESD
IZ

UCP UCP - ESD TYP. 8


F I IZ F

SDV
LOCAL RESET

PARTIAL SDY SDY HS


STROKE IA
A B L
TEST
DEVICE
FB
NOTE 2
G LOCAL CONTROL PANEL FC G

ZSH ZSL ZT

SDV

FB
H FC H

TYPICAL 9
ON - OFF VALVE (UCP CONTROL) (NOTE 3)

EXPANDED DETAILS P&ID REPRESENTATION

DISCREPANCY OPEN CLOSE


L L

ZLHU ZLLU UADU HSOU HSCU

UCP
I

UCP TYP. 9
I

M M

UV

UY EX-DE 01 09/08/19 Issue For HAZOP (IFH) P.Martinez J.Dominguez A.Loza G.Vallerga R.Milani
IA EX-DE 00 29/05/19 Issue For Comments (IFC) O.Nava J.Dominguez A.Loza G.Vallerga R.Milani
Validity Revision
Status Number Contractor Contractor Contractor Company Company
Date Description
Prepared Verified Approved Checked Approved
Index Revision

LOCAL CONTROL PANEL Company Logo and Business Name Project Name Company Document ID:

Mexico Area 1 –
N 6006C2DPFM07414 N
DRAWING NUMBER:
Development Project
Eni Mexico Job N.
ZSH ZSL
Contractor Logo and Business Name Contractor Document ID:

UV J. Ray McDermott de México S.A de C.V.


Contractor N. 5000015145-A8156
Facility and Sub Facility Name Scale Sheet of Sheets

n.a. 9/18
MEXICO AREA 1- AMOCA WHP1

Document Title Superseeded N. 6006C2BPFM02135 Sh.09


WELLHEAD PLATFORM
P Superseeded by N.CPY P
PIPING & INSTRUMENTATION DIAGRAM Plant Area Unit

SYMBOLS n.a. n.a.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

This document is property of eni ghana exploration and production ltd. It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent. Software: Autocad File Name:6006C2DPFM07414_09.dwg
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

TYPICAL 10 REFERENCE DRAWINGS


BDV WITH SINGLE ACTION ACTUATOR (UCP CONTROL)
NUMBER TITLE
A A
EXPANDED DETAILS P&ID REPRESENTATION 20198.C00.GEN.SDS ITEM NUMBERING

06215.C00.GEN.SDS FACILITY FUNCTIONAL UNITS


DISCREPANCY RESET

ZLH ZLL UAD HSR

GENERAL NOTES:

1. VALVE TYPE TO BE IN ACCORDANCE TO PROJECT PIPING CLASS.

B PAL B
UCP - ESD
IZ

UCP UCP - ESD


TYP. 10
I IZ

PT

BDV NOTES:
1. VOLUME TANK SHALL BE NUMBERED 014600-VA-NNNNN
BDY BDY
2.OPENING PERCENTAGE OF CHOKE VALVE CAN BE DEFINED BY PCS.
C IA C
A B 3.ELECTRICAL ACTUATOR.

FO 4.THE ACTUATOR RECEIVE A SIGNAL (HIC) 4-20mA TO MODULATE CONTROLL OF


VALUE AND SIGNAL FEEDBACK 4-20mA.
LOCAL CONTROL PANEL

ZSH ZSL PI
NOTE PSV
L
1
BDV

D D

FO

TYPICAL 11
ELECTRIC MOTOR OPERATED VALVE (UCP CONTROLLED)

EXPANDED DETAILS P&ID REPRESENTATION

E E

STOP OPEN
HSZ HSO UAL OPEN UAX FAILURE ZI VALVE
POSITION
CLOSE CLOSE INDICATOR

UCP
I

TYP. 11
F F

UCP
I

MOV

G G

ZSH ZSL

MOV

H H

TYPICAL 12
TYPICAL FOR MOTORIZED CHOKE VALVE

EXPANDED DETAILS P&ID REPRESENTATION

L L
LOC/REM STOP OPEN OPENED FAILURE VALVE
HSL HSZ HSO UAL UAX ZI
POSITION
CLOSE OPENED INDICATOR

PCS
I

PCS
I
HSO
(NOTE 2,3,4)
M M
OPEN

HSC HV
M

CLOSE

EX-DE 01 09/08/19 Issue for HAZOP (IFH) P.MartinezJ. Dominguez A.Loza G. Vallerga R.Milani
EX-DE 00 29/05/19 Issue for comments (IFC) O.Nava J. Dominguez A.Loza G. Vallerga R.Milani
Validity Revision
Status Number Contractor Contractor Contractor Company Company
HSZ Date Description
Prepared Verified Approved Checked Approved
ZT ZSH ZSL Index Revision

Company Logo and Business Name Project Name Company Document ID:
STOP
Mexico Area 1 –
N 6006C2DPFM07414 N
DRAWING NUMBER:
Development Project
HV HSL
M Eni Mexico Job N.

Contractor Logo and Business Name Contractor Document ID:


LOC/REM

J. Ray McDermott de México S.A de C.V.


Contractor N. 5000015145-A8156
Facility and Sub Facility Name Scale Sheet of Sheets

n.a. 10/18
MEXICO AREA 1- AMOCA WHP1

Document Title Superseeded N. 6006C2BPFM02135 Sh.10


WELLHEAD PLATFORM
P Superseeded byCPY
N. P
PIPING & INSTRUMENTATION DIAGRAM Plant Area Unit

SYMBOLS n.a. n.a.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

This document is property of eni ghana exploration and production ltd. It shall neither be shown to Third Parties not used for purposes other than those Software: Autocad File Name:6006C2DPFM07414_10.dwg
for which it has been sent.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

REFERENCE DRAWINGS

LEVEL INSTRUMENTATION WITH BRIDLE WITH SB&B (NOTE 1) LEVEL INSTRUMENTATION WITH DB&B (NOTE 1) FLOW ORIFICE WITH DB&B
NUMBER TITLE
A A

P&ID REPRESENTATION P&ID REPRESENTATION P&ID REPRESENTATION P&ID REPRESENTATION P&ID REPRESENTATION 20198.COO.GEN.SDS ITEM NUMBERING

06215.COO.GEN.SDS FACILITY FUNCTIONAL UNITS

VESSEL VESSEL
VESSEL VESSEL
GENERAL NOTES:
FT

B 1. P
ROVIDE VALVE DRAINS AT THE LINE LOWEST POINTS AND VALVED VENTS AT THE LINEBHIGHEST POINTS.
LG LT LT LG LT LT
(NOTE 5) (NOTE 5)
2. CD LINES WHICH ARE CONNECTED TO THE CLOSED DRAIN NETWORK SHALL BE SLOPED, NO POCKET LINES

3. SY LINES WHICH ARE CONNECTED TO THE OPEN DRAIN NETWORK SHALL BE SLOPED, NO POCKET LINES.

C
NOTES: C

TYPICAL PROCESS CONNECTION (NOTE 3) TYPICAL PROCESS CONNECTION (NOTE 3) TYPICAL PROCESS CONNECTION (NOTE 3) TYPICAL PROCESS CONNECTION (NOTE 3) TYPICAL PROCESS CONNECTION (NOTE 3) 1. D
B&B FOR RATING > 300#. SB&B FOR RATING = 300#.

2. IF INSTRUMENT IS USED FOR ESD INSOLATION VALVES SHALL BE CAR SEAL OPEN (CSO).

3. FOR TYPE OF VALVES AND DIAMETER REFER TO PIPING CLASS SPECIFICATION OR VESSEL TRIM.
V V

4. STAND PIPE VENT TO ATMOSPHERE TO BE LOCATED AT SAFE LOCATION.

5. TYPICAL VALID ALSO FOR SINGLE LEVEL GAUGE INSTALLATION.

D 2" 2" FT D
VESSEL VESSEL

1" (NOTE 2) 1"


1" 2" 1" 2"
VESSEL VESSEL INSTRUMENT
NSTRUM ENT PIPING

NSTRUM ENT
NSTRUM ENT

NSTRUM ENT

NSTRUM ENT

NSTRUM ENT
(NOTE 2) (NOTE 2)
NG

NG
NG

NG

NG

NG
LT LT
PI

PI
LG LG
PI

PI

PI

PI
LT LT
PI

PI
PI

PI

PI

PI
I

I
I

I
E E
2" 2"
1" 1"
1" 1"
(NOTE 2)

2" 2"
FE

F F
D D

FLOW ORIFICE WITH SB&B PRESSURE INSTRUMENT WITH DB&B PRESSURE INSTRUMENT WITH SB&B TEMPERATURE INSTRUMENT ELECTRICALLY TRACED (GENERIC) INSTRUMENT

P&ID REPRESENTATION P&ID REPRESENTATION P&ID REPRESENTATION P&ID REPRESENTATION P&ID REPRESENTATION

G G

PT PT TT
FT

H H

L
TYPICAL PROCESS CONNECTION (NOTE 3) TYPICAL PROCESS CONNECTION (NOTE 3) TYPICAL PROCESS CONNECTION (NOTE 3) TYPICAL PROCESS CONNECTION (NOTE 3) L

TT TW

PT PT
TE
NSTR.

NSTR.

FT
NG I

NG I

NSTR.

M M
INSTRUMENT
PI

PI
PI

PI

PIPING (NOTE 2) (NOTE 2)


NG I

1-1/2"
(NOTE 2) (NOTE 2) PIPING PIPING
PI

PIPING
PI

EX-DE 01 09/08/19 Issue for HAZOP (IFH) P. Martinez J. Dominguez A.Loza G. Vallerga R.Milani
EX-DE 00 29/05/19 Issue for comments (IFC) M Trujillo J. Dominguez A.Loza G. Vallerga R.Milani
Validity Revision
PT PT Contractor Contractor Contractor Company Company
Status Number
TT TW Date Description
Prepared Verified Approved Checked Approved
NSTR.

NSTR.

Index Revision

Company Logo and Business Name Project Name Company Document ID:

Mexico Area 1 –
N TE 6006C2DPFM07414 N
NG I

NG I

DRAWING NUMBER:
Development Project
Eni Mexico Job N.
PI

PI

Contractor Logo and Business Name Contractor Document ID:


PI

PI

FE (NOTE 2) (NOTE 2)
NSTR.

VESSEL VESSEL J. Ray McDermott de México S.A de C.V.


Contractor N. 5000015145-A8156
NG I

2" Facility and Sub Facility Name Scale Sheet of Sheets

n.a. 11/18
MEXICO AREA 1- AMOCA WHP1
PI

VESSEL
PI

Document Title Superseeded N. 6006C2BPFM02135 Sh.11


WELLHEAD PLATFORM
P Superseeded by N.CPY P
PIPING & INSTRUMENTATION DIAGRAM Plant Area Unit

SYMBOLS n.a. n.a.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

This document is property of eni ghana exploration and production ltd. It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent. Software: Autocad File Name:6006C2DPFM07414_11.dwg
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

REFERENCE DRAWINGS

LEVEL INSTRUMENT (INTERFACE LEVEL TYPE) WITH DB&B LEVEL INSTRUMENT (INTERFACE LEVEL TYPE) WITH DB&B H S SERVICE NUMBER TITLE
A A

20198.COO.GEN.SDS ITEM NUMBERING COMPANY SPECIFICATION


P&ID REPRESENTATION P&ID REPRESENTATION

VESSEL
VESSEL
NOTES:

1. FOR TYPE OF VALVES AND DIAMETER REFER TO PIPING CLASS SPECIFICATION


ALL TRIM NUMERED ACCORDING TO LINE IDENTIFICATION
B LG LT LT B
(NOTE 3) 2. WHERE BLEEDS ARE COLLECTED SHALL BE SPECIFIED:

FH FOR VENTS COLLECTED TO HIGH PRESSURE FLARE

RJ FOR VENTS COLLECTED TO LOW PRESSURE FLARE

DC FOR DRAINS COLLECTED TO CLOSED DRAIN

DC DC 3. TYPICAL VALID ALSO FOR SINGLE LEVEL GAUGE INSTALLATION

C C

TYPICAL PROCESS CONNECTION (NOTE 1) TYPICAL PROCESS CONNECTION (NOTE 1)

D 2" D
VESSEL

1"
1" 2"
VESSEL

NSTRUM ENT
NSTRUM ENT

NSTRUM ENT

NG
NG

NG

LT

PI
LG
PI

PI

LT

PI
PI

PI

I
I

2"
E 1" E
1"

2"
NSTR.

NSTR.

NSTR.
NG I

NG I

NG I
PI

PI

PI
PI

PI

PI

DC DC
F F

D D

LEVEL INSTRUMENT (INTERFACE LEVEL TYPE) WITH SB&B

P&ID REPRESENTATION P&ID REPRESENTATION P&ID REPRESENTATION P&ID REPRESENTATION

VESSEL
G G
VESSEL

LG LT LT
(NOTE 3)

H H

DC DC

TYPICAL PROCESS CONNECTION (NOTE 1) TYPICAL PROCESS CONNECTION (NOTE 1)

L L
2"
VESSEL

1"
1" 2"
VESSEL
NSTRUM ENT
NSTRUM ENT

NSTRUM ENT

NG
NG

NG

LT
PI

LG
PI

PI

LT
PI
PI

PI

I
I

M 2" M
1"
1"

2"
NSTR.

NSTR.

NSTR.

EX-DE 01 09/08/19 Issue for HAZOP (IFH) P.Martinez J. Dominguez A.Loza G. Vallerga R.Milani
EX-DE 00 29/05/19 Issue for comments (IFC) O.Nava J. Dominguez A.Loza G. Vallerga R.Milani
NG I

NG I

NG I

Validity Revision
Status Number Contractor Contractor Contractor Company Company
Date Description
PI

PI

PI

Prepared Verified Approved Checked Approved


Index Revision
PI

PI

PI

2" 2" Company Logo and Business Name Project Name Company Document ID:

DC DC Mexico Area 1 –
N 6006C2DPFM07414 N
DRAWING NUMBER:
Development Project
D D Eni Mexico Job N.

Contractor Logo and Business Name Contractor Document ID:

J. Ray McDermott de México S.A de C.V.


Contractor N. 5000015145-A8156
Facility and Sub Facility Name Scale Sheet of Sheets

n.a. 12/18
MEXICO AREA 1- AMOCA WHP1

Document Title Superseeded N. 6006C2BPFM02135 Sh.12


WELLHEAD PLATFORM
P Superseeded by N.CPY P
PIPING & INSTRUMENTATION DIAGRAM Plant Area Unit

SYMBOLS n.a. n.a.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

This document is property of eni ghana exploration and production ltd. It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent. Software: Autocad File Name:6006C2DPFM07414_12.dwg
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

REFERENCE DRAWINGS

NUMBER TITLE
2oo3 SHUTDOWN - UCP ESD
A A

20198.COO.GEN.SDS ITEM NUMBERING

P&ID REPRESENTATION EXPANDED DETAILS


06215.COO.GEN.SDS FACILITY FUNCTIONAL UNITS

NOTES:

1. XALL AND XAHH AS APPLICABLE THE INITIATING VARIABLE (X) CAN BE ANY INITIATOR AS P.T.
OR L.
B B

DISCREPANCY
2oo3
XAHH XAHH XI UAD UAD
NOTE 1
B

C C

XAHH XI XI XI XI XI

A A B C C

UCP ESD UCP


IZ IZ

D D
2oo3

XT XT XT XT XT XT

A B C A B C

E E

F F

2oo3 SHUTDOWN - ESD

P&ID REPRESENTATION EXPANDED DETAILS


G G

H DISCREPANCY H

2oo3
XAHH UAD
NOTE 1

XAHH XI XI XI

L A B C L

ESD ESD
IZ IZ

2oo3

M M

XT XT XT XT XT XT

A B C A B C

EX-DE 01 09/08/19 Issue for HAZOP (IFH) P. Martinez J. Dominguez A.Loza G. Vallerga R.Milani
EX-DE 00 29/05/19 Issue for comments (IFC) O. Nava J. Dominguez A.Loza G. Vallerga R.Milani
Validity Revision
Status Number Contractor Contractor Contractor Company Company
Date Description
Prepared Verified Approved Checked Approved
Index Revision

Company Logo and Business Name Project Name Company Document ID:

Mexico Area 1 –
N 6006C2DPFM07414 N
DRAWING NUMBER:
Development Project
Eni Mexico Job N.

Contractor Logo and Business Name Contractor Document ID:

J. Ray McDermott de México S.A de C.V.


Contractor N. 5000015145-A8156
Facility and Sub Facility Name Scale Sheet of Sheets

n.a. 13/18
MEXICO AREA 1- AMOCA WHP1

Document Title Superseeded N. 6006C2BPFM02135 Sh.13


WELLHEAD PLATFORM
P Superseeded by N.CPY P
PIPING & INSTRUMENTATION DIAGRAM Plant Area Unit

SYMBOLS n.a. n.a.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

This document is property of eni ghana exploration and production ltd. It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent. Software: Autocad File Name:6006C2DPFM07414_13.dwg
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

ELECTRIC USERS CONNECTED TO ESD/DCS REFERENCE DRAWINGS

NUMBER TITLE
A
TYPICAL: MOT-1 TYPICAL: MOT-2 TYPICAL: MOT-3 A

20198.COO.GEN.SDS ITEM NUMBERING

EXPANDED DETAILS P&ID REPRESENTATION EXPANDED DETAILS P&ID REPRESENTATION EXPANDED DETAILS P&ID REPRESENTATION
09215.COO.GEN.SDS FACILITY FUNCTIONAL UNITS

ESD ESD ESD


IZ IZ IZ

M IL PB NOTES:

M M M M M 1. CONNECTION BETWEEN DCS AND MCC SHOULD BE ALSO VIA SERIAL LINK.IT DEPENDS BY
ON
THE MCC TECHNOLOGY
PB IL
B MCC B
ESD
XS HS
ESD MCC ESD
ESD ESD ESD
XS IZ IZ XS IZ
PB IL
MCC MCC MCC MCC MCC

TYP. MOT-1 IL PB TYP. MOT-2 TYP. MOT-3

PCS PCS OFF PCS DCS DCS


I FROM I FROM LSD I FROM I FROM I FROM
MAIN/STAND BY I MAIN/STAND BY
MAIN/STAND BY MAIN/STAND BY MAIN/STAND BY
SELECTOR HS-NNN SELECTOR HS-NNN SELECTOR HS-NNN SELECTOR HS-NNN SELECTOR HS-NNN

C C
PCS
I
LOCAL CONTROL FROM
START/STOP MAIN/STAND BY UNAVAILABLE RUNNING/STOPPED
ENABLE
SELECTOR HS-NNN
MHSL MHSY LOCAL CONTROL MUAP MULH
ENABLE START/STOP
PCS
MHSL MHSY

UNAVAILABLE RUNNING/STOPPED
UNAVAILABLE RUNNING/STOPPED
MUAP MULH
MUAP MULH

D D

MHSB

AUT/MAN

TYPICAL: MOT-7 TYPICAL: HEATER-1 TYPICAL: COOLER-2

EXPANDED DETAILS P&ID REPRESENTATION EXPANDED DETAILS P&ID REPRESENTATION EXPANDED DETAILS P&ID REPRESENTATION

E E
ESD ESD ESD
IZ IZ IZ

M IL PB

VSHH
M M M
ON
NNNA
PB IL
MCC
ESD
XS HS
MCC ESD ESD
ESD ESD ESD
IZ XS IZ XS IZ
PB IL MCC MCC MCC MCC MCC
DCS
I
F F

IL PB TYP. MOT-7 TYP. HEATER-1 TYP. COOLER-2

OFF PCS DCS DCS DCS DCS


I I I I I
(START/STOP)
LSD
I

VAHH
PCS
I
LOCAL CONTROL
UNAVAILABLE RUNNING/STOPPED ENABLE START/STOP

LOCAL CONTROL MUAP MULH MHSL MHSY


ENABLE START/STOP
G G
PCS
MHSL MHSY

UNAVAILABLE RUNNING/STOPPED
UNAVAILABLE (TRIP) RUNNING/STOPPED
MUAP MULH
MUAP MULH

MHSB MHSB

AUT/MAN AUT/MAN
H H

TYPICAL: TCP TYPICAL: VSD-1 TYPICAL: COOLER-3

EXPANDED DETAILS P&ID REPRESENTATION EXPANDED DETAILS P&ID REPRESENTATION EXPANDED DETAILS P&ID REPRESENTATION

ESD ESD ESD


IZ IZ IZ

L M M L

VSHH
M M
ESD NNNA
ESD
XS IZ
VSD VSD

ESD ESD ESD ESD


XS IZ TYP. VSD XS IZ
TCP TCP MCC MCC
DCS
I
DCS DCS
I FROM I
TYP. TCP TYP. COOLER-3
MAIN/STAND BY
M M
SELECTOR HS-NNN FROM
DCS DCS DCS DCS
I I MAIN/STAND BY I I
SELECTOR HS-NNN
LOCAL CONTROL
ENABLE START/STOP
VAHH
MHSL MHSY
LOCAL CONTROL EX-DE 01 09/08/19 Issue for HAZOP (IFH) P.Martinez J. Dominguez A.Loza G. Vallerga R.Milani
UNAVAILABLE RUNNING/STOPPED START/STOP EX-DE 00 29/05/19 Issue for comments (IFC) O.Nava J. Dominguez A.Loza G. Vallerga R.Milani
ENABLE
Validity Revision
Contractor Contractor Contractor Company Company
MUAP MULH MHSL MHSY Status Number
Date Description
Prepared Verified Approved Checked Approved
Index Revision
UNAVAILABLE RUNNING/STOPPED
Company Logo and Business Name Project Name Company Document ID:

MUAP MULH Mexico Area 1 –


N 6006C2DPFM07414 N
DRAWING NUMBER:
Development Project
UNAVAILABLE RUNNING/STOPPED Eni Mexico Job N.

Contractor Logo and Business Name Contractor Document ID:


MUAP MULH
SPEED/LOAD
MANUAL CONTROL SPEED/LOAD
J. Ray McDermott de México S.A de C.V.
MHIC MSI Contractor N. 5000015145-A8156
Facility and Sub Facility Name Scale Sheet of Sheets

n.a. 14/18
MEXICO AREA 1- AMOCA WHP1

MHSB Document Title Superseeded N. 6006C2BPFM02135 Sh.14


WELLHEAD PLATFORM
P Superseeded by N.CPY P
PIPING & INSTRUMENTATION DIAGRAM Plant Area Unit

AUT/MAN SYMBOLS n.a. n.a.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

This document is property of eni ghana exploration and production ltd. It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent. Software: Autocad File Name:6006C2DPFM07414_14.dwg
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

REFERENCE DRAWINGS

NUMBER TITLE
A A

20198.COO.GEN.SDS ITEM NUMBERING


ELECTRIC USERS CONNECTED TO UCP
06215.COO.GEN.SDS FACILITY FUNCTIONAL UNITS

TYPICAL: MOT-4 TYPICAL: MOT-5 TYPICAL: MOT-6

EXPANDED DETAILS P&ID REPRESENTATION EXPANDED DETAILS P&ID REPRESENTATION EXPANDED DETAILS P&ID REPRESENTATION
NOTES:
UCP-ESD UCP-ESD ESD
IZ I IZ 1. CONNECTION BETWEEN UCP AND MCC SHOULD BE ALSO VIA SERIAL LINK. IT DEPENDS BY
THE MCC TECHNOLOGY
B B

M M M M M M

UCP-ESD UCP-ESD UCP-ESD UCP-ESD ESD


XS IZ XS IZ XS IZ
MCC MCC MCC MCC MCC MCC

TYP. MOT-4 TYP. MOT-5 TYP. MOT-6

C C
UCP UCP UCP UCP UCP UCP
I FROM I FROM I FROM I FROM I FROM I FROM
MAIN/STAND BY MAIN/STAND BY MAIN/STAND BY MAIN/STAND BY MAIN/STAND BY MAIN/STAND BY
SELECTOR HS-NNN SELECTOR HS-NNN SELECTOR HS-NNN SELECTOR HS-NNN SELECTOR HS-NNN SELECTOR HS-NNN

LOCAL CONTROL LOCAL CONTROL


START/STOP ENABLE START/STOP
ENABLE

MHSLU MHSY MHSLU MHSYU

D D
UNAVAILABLE RUNNING/STOPPED UNAVAILABLE RUNNING/STOPPED UNAVAILABLE RUNNING/STOPPED

MUAPU MULHU MUAPU MULHU MUAPU MULHU

MUAP MHSBU MULH MUAP MHSYU MULH MUAP MHSBU MULH

AUT/MAN START/STOP AUT/MAN

TYPICAL: COOLER-1 TYPICAL: VSD-2 TYPICAL: HEATER-2


E E

EXPANDED DETAILS P&ID REPRESENTATION EXPANDED DETAILS P&ID REPRESENTATION EXPANDED DETAILS P&ID REPRESENTATION

UCP-ESD
IZ
UCP-ESD UCP-ESD
IZ IZ

M M
M M

F F
UCP-ESD
UCP-ESD
XS IZ
UCP-ESD UCP-ESD UCP-ESD UCP-ESD
XS IZ VSD VSD XS IZ
MCC MCC MCC MCC

TYP. VSD
TYP. COOLER-1 TYP. HEATER-2
UCP UCP
FROM FIC - NNN I FROM I
UCP UCP UCP UCP
I I MAIN/STAND BY I I
(OR LIC OR PIL)
(START/STOP)
SELECTOR HS-NNN FROM
LOCAL CONTROL MAIN/STAND BY
ENABLE START/STOP SELECTOR HS-NNN
G G
MHSLU MHSYU
LOCAL CONTROL
START/STOP UNAVAILABLE RUNNING/STOPPED
ENABLE

MHSLU MHSYU MUAP MUAPU MULHU MULH

UNAVAILABLE RUNNING/STOPPED

MUAP MUAPU MULHU MULH

UNAVAILABLE RUNNING/STOPPED

MUAPU MULHU
SPEED/LOAD
MANUAL CONTROL SPEED/LOAD
H H
MHICU MSIU

MUAP MHSBU MULH MHSBU

AUT/MAN AUT/MAN

TYPICAL: SEAL PLAN

L EXPANDED DETAILS P&ID REPRESENTATION L

SEAL
PT PI PLAN

M PT M
PI

LT LI
M LT LI

EX-DE 01 09/08/19 Issue For HAZOP (IFH) P.Martinez J.Dominguez A.Loza G.Vallerga R.Milani
EX-DE 00 29/05/19 Issue For Comments (IFC) O.Nava J.Dominguez A.Loza G.Vallerga R.Milani
M Validity Revision
Contractor Contractor Contractor Company Company
Status Number Description
Date
Prepared Verified Approved Checked Approved
Index Revision

Company Logo and Business Name Project Name Company Document ID:

Mexico Area 1 –
N 6006C2DPFM07414 N
DRAWING NUMBER:
Development Project
Eni Mexico Job N.

Contractor Logo and Business Name Contractor Document ID:

J. Ray McDermott de México S.A de C.V.


Contractor N. 5000015145-A8156
1 2
Facility and Sub Facility Name Scale Sheet of Sheets

n.a. 15/18
MEXICO AREA 1- AMOCA WHP1
1. COOLING WATER IN
Document Title Superseeded N. 6006C2BPFM02135 Sh.15

2. COOLING WATER OUT WELLHEAD PLATFORM


P Superseeded by N.CPY P
PIPING & INSTRUMENTATION DIAGRAM Plant Area Unit

SYMBOLS n.a. n.a.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

This document is property of eni ghana exploration and production ltd. It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent. Software: Autocad File Name:6006C2DPFM07414_15.dwg
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

REFERENCE DRAWINGS
SAMPLE POINT TYPE "B3" SAMPLE POINT TYPE "D3"
FOR LIQUID HYDROCARBON AND GLYCOL SAMPLES ABOVE 60 °C FOR LIQUID HYDROCARBON AND GLYCOL SAMPLES BELOW 60 °C
A A
ON PROCESS EQUIPMENT WITH RATING ≥ 600# AND H S SERVICE ON PROCESS EQUIPMENT WITH RATING ≤ 300#

EXPANDED DETAILS P&ID REPRESENTATION EXPANDED DETAILS P&ID REPRESENTATION

PORTABLE SAMPLE RECEIVER

TO CLOSED/GLYCOL
GENERAL NOTES:
DRAIN SYSTEM

NLESS STEEL
B PI TYP. "D3" B
PI
1. PROVIDE VALVE DRAINS AT THE LINE LOWEST POINTS AND VALVED VENTS AT THE LINE HIGHEST POINTS.

PROCESS SPEC
SP

XXX 2. CD LINES WHICH ARE CONNECTED TO THE CLOSED DRAIN NETWORK SHALL BE SLOPED, NO POCKET LINES.
1/2"x1/4" 1/2"x1/4"
TYP. "B3"

STAI
1/4" 1/4" 1/2" 3. LINES WHICH ARE CONNECTED TO THE OPEN DRAIN NETWORK SHALL BE SLOPED, NO POCKET LINES.
LS
SP
XXX

XXX
2"

4"
1/

1/

PROCESS 1" PROCESS SPEC


D
EQUIPMENT STAINLESS STEEL
THERMAL 1"
C C
EXPANSION LOOP NOTES:
4"
1/

1"x3/4"
1. PREFERRED SAMPLE TAKE OFF POSITIONIS FROM A VERTICAL LINE, WHERE IS NOT POSSIBLE SAMPLE TAKE
TAKE OFF SHALL BE INSTALLED AT SIDE OF THE PIPE IN 4 O´CLOCK POSITION.
1/4"
3/4" 2. FREQUENTLY USED SAMPLE CONNECTIONS TO BE LOCATED AT GRADE LEVEL WHERE POSSIBLE.

3. SAMPLE BOTTLE TO BE SUPPLIED COMPLETE WITH METALLIC HOSES AND QUICK CONNECTIONS BOTH

HOLD 1 D ENDS.

1/4" 4. SAMPLE LINE TO BE INSULATED FOR PERSONNEL PROTECTION UPSTREAM OF COOLER.

5. MINIMIZE DISTANCE FROM PROCESS TAKE-OFF TO SAMPLE CONNECTION.

NSTRUMENT
D D
6. FREQUENTLY USED SAMPLE CONNECTIONS TO BE LOCATED AT GRADE LEVEL WHERE POSSIBLE.

3/4" 1"

I
1/2" MNPT x 1/2" O.D. TUBING CONNECTOR

NG
NSTRUMENT

PI
PI

PI
1" ASME CLASS 2500 RJ BLIND FLANGE
S
CENTER DRILLED & TAPPED W/ 1/2" FNPT 1"
IPING

E 1/2" NPT-F E
PI

CLOSED DRAINS SAMPLE BOTTLE


(VERTICAL)

(NOTE 2, 6)

SAMPLE PROBE
(SPECIAL PART)

PROCESS LINE
F F

SAMPLE POINT TYPE "D4"


FOR LIQUID HYDROCARBON AND GLYCOL SAMPLES BELOW 60 °C
ON PROCESS EQUIPMENT WITH RATING ≥600# AND H2S SERVICE

EXPANDED DETAILS P&ID REPRESENTATION

G G

TO CLOSED/GLYCOL
DRAIN SYSTEM

TYP. "D4"
SP

XXX
H H

PROCESS
EQUIPMENT

1"
PROCESS SPEC

STAINLESS STEEL
D 1"

PROCESS SPEC 1"


L L
STAINLESS STEEL

1"x3/4"
3/4"

HOLD 1

3/4" 1"

M M

1"
PI

EX-DE 01 09/08/19 Issue For HAZOP (IFH) P.Martinez J.Dominguez A.Loza G.Vallerga R.Milani
EX-DE 00 29/05/19 Issue For Comments (IFC) O.Nava J.Dominguez A.Loza G.Vallerga R.Milani
Validity Revision
Status Number Contractor Contractor Contractor Company Company
1/2" NPT-F Date Description
Prepared Verified Approved Checked Approved
Index Revision

Company Logo and Business Name Project Name Company Document ID:
SAMPLE BOTTLE
Mexico Area 1 –
N 6006C2DPFM07414 N
(VERTICAL) DRAWING NUMBER:
Development Project
Eni Mexico Job N.
(NOTE 2, 6)
Contractor Logo and Business Name Contractor Document ID:

J. Ray McDermott de México S.A de C.V.


Contractor N. 5000015145-A8156
Facility and Sub Facility Name Scale Sheet of Sheets

n.a. 16/18
MEXICO AREA 1- AMOCA WHP1

Document Title Superseeded N. 6006C2BPFM02135 Sh.16

P WELLHEAD PLATFORM Superseeded by N.CPY P


PIPING & INSTRUMENTATION DIAGRAM Plant Area Unit

SIMBOLS n.a. n.a.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

This document is property of eni ghana exploration and production ltd. It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent. Software: Autocad File Name:6006C2DPFM07414_16.dwg
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

REFERENCE DRAWINGS

SAMPLE POINT TYPE "C1" SAMPLE POINT TYPE "D1"

FOR GAS SAMPLES ON PROCESS LINE WITH RATING < 300# FOR LIQUID HYDROCARBON AND GLYCOL SAMPLES BELOW 60 °C
A A
ON PROCESS LINE WITH RATING ≤ 300#

EXPANDED DETAILS P&ID REPRESENTATION EXPANDED DETAILS P&ID REPRESENTATION

PROCESS LINE GENERAL NOTES:


TYP. "C1" (NOTE 3)
(NOTE 2)
V
TO FLARE SYSTEM SP FROM TO CLOSED/GLYCOL 1. PROVIDE VALVE DRAINS AT THE LINE LOWEST POINTS AND VALVED VENTS AT THE LINE HIGHEST POINTS.
B BOTTOM MIN. DRAIN SYSTEM B
XXX
2. CD LINES WHICH ARE CONNECTED TO THE CLOSED DRAIN NETWORK SHALL BE SLOPED, NO POCKET LINES.

3. SY LINES WHICH ARE CONNECTED TO THE OPEN DRAIN NETWORK SHALL BE SLOPED, NO POCKET LINES.

STAINLESS STEEL HIGH POINT 1" PROCESS SPEC


TYP. "D1"
PROCESS SPEC STAINLESS STEEL
1" SP
FROM
NOTES:
XXX
(NOTE 2) MIN. TOP
(NOTE 3)
D 1. SAMPLE BOTTLE TO BE SUPPLIED WITH METALLIC HOSES AND QUICK CONNECTORS
PROCESS LINE PROCESS SPEC AT BOTH ENDS.
C STAINLESS STEEL PROCESS SPEC C
1" 2. MINIMIZE DISTANCE FROM PROCESS TAKE-OFF TO SAMPLE CONNECTION.
STAINLESS STEEL
1"
3. PREFERRED TAKE OFF POSITION IS FROM A VERTICAL LINE. WHERE IS NOT POSSIBLE SAMPLE TAKE OFF
SHALL BE INSTALLED AT THE TOP OF THE PIPE.
1"x3/4" 4. FREQUENTLY USED SAMPLE CONNECTIONS TO BE LOCATED AT GRADE LEVEL WHERE POSSIBLE.
1"x3/4"

3/4"
3/4"

V
HOLD 1 D

D D

3/4" 1"
3/4" 1"

PI
PI
S
1" S
1"

E E

1/2" NPT-F
1/2" NPT-F

SAMPLE BOTTLE
(HORIZONTAL) SAMPLE BOTTLE
(VERTICAL)
(NOTE 1,4)
(NOTE 1,4)

F F

SAMPLE POINT TYPE "C2" SAMPLE POINT TYPE "D2"


FOR LIQUID HYDROCARBON AND GLYCOL SAMPLES BELOW 60 °C
FOR GAS SAMPLES ON PROCESS LINE WITH RATING ≥600# AND H2S SERVICE ON PROCESS LINE WITH RATING ≥600# AND H2S SERVICE

EXPANDED DETAILS P&ID REPRESENTATION


EXPANDED DETAILS P&ID REPRESENTATION

G G
NLESS STEEL

PROCESS LINE
PROCESS SPEC

TYP. "C2"
(NOTE 3)
(NOTE 2)
SP FROM TO CLOSED DRAIN
STAI

BOTTOM MIN. SYSTEM


V XXX
TO FLARE SYSTEM

1" PROCESS SPEC


TYP. "D2"
STAINLESS STEEL
H SP H
HIGH POINT
XXX
1"
D
FROM

(NOTE 2) MIN. TOP


(NOTE 3) PROCESS SPEC

PROCESS LINE PROCESS SPEC STAINLESS STEEL


PROCESS SPEC 1" 1"
STAINLESS STEEL
1" STAINLESS STEEL

1"x3/4"
L L
1"x3/4"

3/4"

3/4"
HOLD 1

HOLD 1
D
V

3/4" 1"

3/4" 1"
M M

PI 1"

PI 1" S

EX-DE 01 09/08/19 Issue For HAZOP (IFH) P.Martinez J.Dominguez A.Loza G.Vallerga R.Milani
EX-DE 00 29/05/19 Issue For Comments (IFC) O.Nava J.Dominguez A.Loza G.Vallerga R.Milani
1/2" NPT-F Validity Revision
Status Number Contractor Contractor Contractor Company Company
Date Description
1/2" NPT-F Index Revision
Prepared Verified Approved Checked Approved

SAMPLE BOTTLE Company Logo and Business Name Project Name Company Document ID:
(VERTICAL) Mexico Area 1 –
N SAMPLE BOTTLE N
DRAWING NUMBER:
Development Project
6006C2DPFM07414
(HORIZONTAL)
(NOTE 1,4) Eni Mexico Job N.

(NOTE 1,4) Contractor Logo and Business Name Contractor Document ID:

J. Ray McDermott de México S.A de C.V.


Contractor N. 5000015145-A8156
Facility and Sub Facility Name Scale Sheet of Sheets

n.a. 17/18
MEXICO AREA 1- AMOCA WHP1

Document Title Superseeded N. 6006C2BPFM02135 Sh.17


WELLHEAD PLATFORM
P Superseeded by N.CPY P
PIPING & INSTRUMENTATION DIAGRAM Plant Area Unit

SYMBOLS n.a. n.a.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

This document is property of eni ghana exploration and production ltd. It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent. Software: Autocad File Name:6006C2DPFM07414_17.dwg
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

REFERENCE DRAWINGS

SAMPLE POINT TYPE "C3" DETAIL 1


A NON-HAZARDOUS LIQUID SAMPLES WITH ATM. BOILING TEMPERATURES INSTRUMENT & MEG INJECTION CONNECTIONS - PRODUCTION WELLHEADS A

ABOVE THE SAMPLE TEMPERATURE FOR ALL POSSIBLE COMPOSITIONS (TYPICAL FOR 4 WELLHEADS)

EXPANDED DETAILS P&ID REPRESENTATION TYPICAL DETAIL - SIDE VIEW P&ID REPRESENTATION

PT/TT

PG
GENERAL NOTES:

A.PROVIDE VALVE DRAINS AT THE LINE LOWEST POINTS AND VALVED VENTS AT THE LINE HIGHEST
NE
PROCESS LI

MANUAL POINTS.
B WING B. CD LINES WHICH ARE CONNECTED TO THE CLOSED DRAIN NETWORK SHALL BE SLOPED, NO B
"A"
VALVE POCKET LINES.

ON
1 1/2" TYP. "C3"

WELLHEAD
C.LINES WHICH ARE CONNECTED TO THE OPEN DRAIN NETWORK SHALL BE SLOPED, NO POCKET

PRODUCTI
SP
LINES.
PI PT TT
XXX

"A" WV

X
N.

BY FMC)
16"API10000RJ
600mm MI

NSTRUMENTFLANGE
1 1/2" x 1/2" NOTES:
1. MINIMUM DISTANCE FOR BOTTLE.

(
C
SEE COMMENTS PAGE 18 C

41/
1/2"

I
1/2" x 1/4" MEG
INJECTION

INSTR.PIPING PIPING INSTR.


PG PT/TT
500

TO OPEN DRAINS SYSTEM


1/2"
D D

9/16" AUTOCLAVE 9/16" AUTOCLAVE

4 1/16" API 10000 RJ


1" AUTOCLAVE
INSTRUMENT FLANGE
(BY FMC)

MALE x MALE
E E
AUTOCLAVE ADAPTER
1" AUTOCLAVE
W/ PLUG
1"-SP-019 DBB WITH
INTEGRAL CHECK VALVE

X
ASME CLASS 10000 RJ x 1"
AUTOCLAVE

1" ASME CLASS 10000 RJ BLIND FLANGE,


ASTM A182 GR. F51 DUPLEX SS, SECTION "A-"A"

CENTER DRILLED & TAPPED


1"-FUJD

F F
MEG
INJECTION

DETAIL 2 DETAIL 3
INSTRUMENT CONNECTIONS AT PRODUCTION CASING - PRODUCTION WELLHEADS INSTRUMENT CONNECTIONS - WATER INJECTION WELLHEADS
(TYPICAL FOR 4 WELLHEADS) (TYPICAL FOR 5 WELLHEADS)

TYPICAL DETAIL - SIDE VIEW P&ID REPRESENTATION TYPICAL DETAIL - SIDE VIEW P&ID REPRESENTATION

G G

PT/TT PT

PG
PG
PI PT TT

PI PT

MANUAL
HV CASING GAS
WING
CHOKE VALVE "A"

ON
"A" VALVE

NJECTI
ON

WELLHEAD
WELLHEAD
PRODUCTI

H H
WATER I

BY FMC)
8"API10000RJ
NSTRUMENTFLANGE
"A" "A"
CGV WV

(
51/

MANUAL
2 1/16" API 5000 RJ
PRODUCTION
INSTRUMENT FLANGE
CASING VALVE
I

(BY FMC)

L L

INSTR.PIPING PIPING INSTR.


PG PT/TT PG PT

9/16" AUTOCLAVE 9/16" AUTOCLAVE 9/16" AUTOCLAVE 9/16" AUTOCLAVE

M M

2 1/16" API 10000 RJ


INSTRUMENT FLANGE
(BY FMC)
5 1/8" API 10000 RJ
1" AUTOCLAVE INSTRUMENT FLANGE

MALE x MALE (BY FMC)


EX-DE 01 09/08/19 Issue For HAZOP (IFH) P.Martinez J.Dominguez A.Loza G.Vallerga R.Milani
AUTOCLAVE ADAPTER
EX-DE 00 29/05/19 Issue For Comments (IFC) O.Nava J.Dominguez A.Loza G.Vallerga R.Milani
9/16" AUTOCLAVE 1" AUTOCLAVE Validity Revision
W/ PLUG 1" AUTOCLAVE Contractor Contractor Contractor Company Company
W/ PLUG Status Number
Date Description
W/ PLUG Prepared Verified Approved Checked Approved
1"-SP-019 DBB WITH Index Revision

INTEGRAL CHECK VALVE Company Logo and Business Name Project Name Company Document ID:

ASME CLASS 10000 RJ x 1" Mexico Area 1 –


N 6006C2DPFM07414 N
AUTOCLAVE
DRAWING NUMBER:
Development Project
Eni Mexico Job N.

Contractor Logo and Business Name Contractor Document ID:


SECTION "A-"A" 1" ASME CLASS 10000 RJ BLIND FLANGE, SECTION "A-"A"
ASTM A182 GR. F51 DUPLEX SS,
CENTER DRILLED & TAPPED J. Ray McDermott de México S.A de C.V.
1"-FUJD Contractor N. 5000015145-A8156
Facility and Sub Facility Name Scale Sheet of Sheets

MEG n.a. 18/18


MEXICO AREA 1- AMOCA WHP1
INJECTION
Document Title Superseeded N. 6006C2BPFM02135 Sh.18
WELLHEAD PLATFORM
P Superseeded by N.CPY P
PIPING & INSTRUMENTATION DIAGRAM Plant Area Unit

SYMBOLS n.a. n.a.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

This document is property of eni ghana exploration and production ltd. It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent. Software: Autocad File Name:6006C2DPFM07414_18.dwg
REFERENCE DRAWINGS
DETAIL 4 DETAIL 5
INSTRUMENT & MEG INJECTION CONNECTIONS - PRODUCTION WELLHEADS INSTRUMENT CONNECTIONS AT PRODUCTION CASING - PRODUCTION WELLHEADS
(TYPICAL FOR 4 WELLHEADS) (TYPICAL FOR 4 WELLHEADS)

TYPICAL DETAIL - SIDE VIEW P&ID REPRESENTATION TYPICAL DETAIL - SIDE VIEW P&ID REPRESENTATION

PT/TT PT

PG GENERAL NOTES:
PG
A. PROVIDE VALVE DRAINS AT THE LOWEST POINTS AND VALVED VENTS AT THE LINE HIGHEST
POINTS.
B. CD LINES WHICH ARE CONNECTED TO THE CLOSED DRAIN NETWORK SHALL BE SLOPED, NO
MANUAL POCKET LINES.
HV CASING GAS C. LINES WHICH ARE CONNECTED TO THE OPEN DRAIN NETWORK SHALL BE SLOPED, NO POCKET
WING
VALVE "A" CHOKE VALVE LINES.
"A"
PI PT TT PI PT TT
PRODUCTION
WELLHEAD

PRODUCTION
WELLHEAD
ADD PLAN 52 SEALING FOR PUMP
CONNECTED TO PCS
"A" WV
4 1/16" API 5000 RJ

(BY FMC)
INSTRUMENT FLANGE

"A" CGV
X

D
MANUAL
PRODUCTION 2 1/16" API 5000 RJ
CASING VALVE INSTRUMENT FLANGE
(BY FMC)

E
PG PT/TT
MEG
INJECTION

PG PT/TT

L
9/16" AUTOCLAVE 9/16" AUTOCLAVE

9/16" AUTOCLAVE 9/16" AUTOCLAVE


2 1/16" API 5000 RJ

L
INSTRUMENT FLANGE
(BY FMC)

9/16" AUTOCLAVE
W/ PLUG 9/16" AUTOCLAVE
4 1/16" API 5000 RJ
1" AUTOCLAVE W/ PLUG
INSTRUMENT FLANGE
(BY FMC)

E
MALE x MALE
AUTOCLAVE ADAPTER 1" AUTOCLAVE
W/ PLUG
1"-SP-019 DBB WITH SECTION "A-"A"
INTEGRAL CHECK VALVE
X

ASME CLASS 2500 RJ x


1" AUTOCLAVE

C
1" ASME CLASS 2500 RJ BLIND FLANGE,
ASTM A182 GR. F51 DUPLEX SS, SECTION "A-"A"
CENTER DRILLED & TAPPED
1"-FUJD

MEG
INJECTION

N
C A
EX-DE 01 09/08/19 Issue For HAZOP (IFH) P.Martinez J.Dominguez A.Loza G.Vallerga R.Milani
EX-DE 00 29/05/19 Issue For Comments (IFC) O.Nava J.Dominguez A.Loza G.Vallerga R.Milani
Validity Revision
Status Number Contractor Contractor Contractor Company Company
Date Description
Prepared Verified Approved Checked Approved
Index Revision
Company Logo and Business Name Project Name Company Document ID:
Mexico Area 1 –
Development Project 6006C2DPFM07414
Eni Mexico Job N.
Contractor Logo and Business Name Contractor Document ID:

J. Ray McDermott de México S.A de C.V.


Contractor N. 5000015145-A8156
Facility and Sub Facility Name Scale Sheet of Sheets

MEXICO AREA 1- AMOCA WHP1 n.a. 19/19

Document Title Superseeded N. 6006C2BPFM02135 Sh.19


WELLHEAD PLATFORM
Superseeded by N. CPY
PIPING & INSTRUMENTATION DIAGRAM Plant Area Unit
SYMBOLS n.a. n.a.

This document is property of eni ghana exploration and production ltd. It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent. Software: Autocad File Name: 6006C2DPFM07414_19.dwg