RMX -NEWTOWN
CLIENT : Furnace Fabrica (India) Ltd
Water Treatment Plant, Near Tank No-1, Street Report Number 00001133
Kolkata - 700156 Sample Date 03-09-2019
State: West Bengal Page 1 of 1
Date 10-09-2019
PROJECT: Furnace Fabrica (India) Ltd
Water Treatment Plant, Near Tank No-1, Street
Kolkata - 700156 This Report replaces all previous issues of report 00001133
State: West Bengal
CONCRETE CUBE COMPRESSIVE TEST REPORT
Delivery Docket No. 13304961 Plant RMX -NEWTOWN
Product Identification ZKPLTR30212PI Sample No. 13304961
Grade of Concrete M30 Specified Slump / Toerance 150 mm
Sampling Location Site Actual Slump 150 mm
Age at Weight Density Load Strength Failure Excluded
Dimensions(mm)
Spec. ID Date Tested Test (Kg) (Kg/m3) (KN) (Mpa) Mode (#) Av. Strength(Mpa)
L W H
13304961 10-09-2019 7 150.0 150.0 150.0 8.355 2476 535.4 23.80 N
13304961 10-09-2019 7 150.0 150.0 150.0 8.380 2483 554.7 24.65 N 24.15
13304961 10-09-2019 7 150.0 150.0 150.0 8.410 2492 540.1 24.00 N
Report Remarks
Failure Mode Condition Prior # 1 Test carried out in presence
N Normal Failure
Laboratory Accredition Number Amrita Kr Biswas
#1: All tests are carried out as per relevant
Indian Standards unless noted otherwise
#2:Results relate only to samples tested
#3:Any correction invalidates the report Approved Signatory:
From No. / Version: From FT7 Ver. 3