Lsc320an02 T Samsung
Lsc320an02 T Samsung
Lsc320an02 T Samsung
( √ ) Preliminary Specification
( ) Approval Specification
Table of Contents
——————————————————————————————————————————————––—
Doc.No. LSC320AN02 Page 2 of 36 Rev.No. 06-000-G-20121228
————————————————————————————————————————————————–
REVISION HISTORY
——————————————————————————————————————————————––—
Doc.No. LSC320AN02 Page 3 of 36 Rev.No. 06-000-G-20121228
————————————————————————————————————————————————–
1. GENERAL DESCRIPTION
DESCRIPTION
This model uses a liquid crystal display (LCD) of amorphous silicon TFT as switching components. This model is
composed of a TFT LCD panel, a driver circuit, and an ass’y KIT of source PBA. This 32.0” model has a
resolution of a 1366 x 768 and can display up to 16.7 million colors with the wide viewing angle of 89° or a
higher degree in all directions. This panel is designed to support applications by providing a excellent
performance function of the flat panel display such as home-alone multimedia TFT-LCD TV and a high
definition TV.
FEATURES
RoHS compliance (Pb-free)
High contrast ratio & aperture ratio with the wide color gamut
PVA(Patterned vertical align) mode
Wide viewing angle (± 178°)
High speed response
HD resolution (16:9)
DE (Data enable) mode
The interface (1Pixel/clock) of LVDS (Low voltage differential signaling)
GENERAL INFORMATION
Item Specification Unit Note
Active Display Area 697.6845 (H) x 392.256 (V) mm
Switching Components a-Si TFT Active matrix
TFT : 713.0(H) x 410.50(V)
Glass size CF : 713.0(H) x 408.20(V) mm
713.0(H) x 410.5(V) mm 16:9
Panel Size
1.80(D) mm
Weight 1200 (Max) g
Display Colors 16.7M (True 8-bit)
Number of Pixels 1,366 × 768
Pixel Arrangement RGB Horizontal Stripe mm
Display Mode Normally Black
Haze 2%
Hardness Hard coating 2H
——————————————————————————————————————————————––—
Doc.No. LSC320AN02 Page 4 of 36 Rev.No. 06-000-G-20121228
————————————————————————————————————————————————–
2. ABSOLUTE MAXIMUM RATINGS
If the figures on measuring instruments exceed maximum ratings, it can cause the malfunction or the
unrecoverable damage on the device.
——————————————————————————————————————————————––—
Doc.No. LSC320AN02 Page 5 of 36 Rev.No. 06-000-G-20121228
————————————————————————————————————————————————–
3. OPTICAL CHARACTERISTICS
The optical characteristics should be measured in the dark room or the space surrounded by the similar
setting. Measuring equipment : TOPCON RD-80S, TOPCON SR-3 ,ELDIM EZ-Contrast
Notice
(a) Setup for test equipment
The measurement should be executed in a stable, windless, and dark room for 40min and 60min after
operating the panel at the given temperature for stabilization of the standard light. (SDC uses the standard
luminance of the D65media).
This measurement should be measured at the center of screen.
The environment condition: Ta = 25 ± 2 °C
——————————————————————————————————————————————––—
Doc.No. LSC320AN02 Page 6 of 36 Rev.No. 06-000-G-20121228
————————————————————————————————————————————————–
SR-3 2°
RD-80S 1°
(c)
The CIE positions D65 as the standard daylight illuminant:
[D65] is intended to represent average daylight and has a correlated color temperature of approximately 6500
K. CIE standard illuminant D65 should be used in all colorimetric calculations requiring representative daylight,
unless there are specific reasons for using a different illuminant.
G max
C/R
G min
——————————————————————————————————————————————––—
Doc.No. LSC320AN02 Page 7 of 36 Rev.No. 06-000-G-20121228
————————————————————————————————————————————————–
Note (2) Definition of response time
Display data
The response of
optical instruments
※ G-to-G : Average response time between the whole gray scale to the whole gray scale.
Gray to Gray Response Time
End
Gray
0 31 63 95 127 159 191 223 255
0 Tr(0-31) Tr(0-63) Tr(0-95) Tr(0-127) Tr(0-159) Tr(0-191) Tr(0-223) Tr(0-255)
31 Tf(31-0) Tr(31-63) Tr(31-95) Tr(31-127) Tr(31-159) Tr(31-191) Tr(31-223) Tr(31-255)
63 Tf(63-0) Tf(63-31) Tr(63-95) Tr(63-127) Tr(63-159) Tr(63-191) Tr(63-223) Tr(63-255)
95 Tf(95-0) Tf(95-31) Tf(95-63) Tr(95-127) Tr(95-159) Tr(95-191) Tr(95-223) Tr(95-255)
Ton
Start 127 Tf(127-0) Tf(127-31) Tf(127-63) Tf(127-95) Tr(127-159) Tr(127-191) Tr(127-223) Tr(127-255)
159 Tf(159-0) Tf(159-31) Tf(159-63) Tf(159-95) Tf(159-127) Tr(159-191) Tr(159-223) Tr(159-255)
191 Tf(191-0) Tf(191-31) Tf(191-63) Tf(191-95) Tf(191-127) Tf(191-159) Tr(191-223) Tr(191-255)
223 Tf(223-0) Tf(223-31) Tf(223-63) Tf(223-95) Tf(223-127) Tf(223-159) Tf(223-191) Tr(223-255)
255 Tf(255-0) Tf(255-31) Tf(255-63) Tf(255-95) Tf(255-127) Tf(255-159) Tf(255-191) Tf(255-223)
Toff
T*(X-Y) : Response time from level of gray at X to level of gray at Y
The definition of response time = Σ [T*(X-Y)] / 72
The response time is the value that was measured after it was operated in Samsung's standard BLU for one
hour.( at room temperature)
Note (3) The definition of luminance of white: The luminance of white at the center point ⑤
The measurement shall be executed with the standard light source of D65
——————————————————————————————————————————————––—
Doc.No. LSC320AN02 Page 8 of 36 Rev.No. 06-000-G-20121228
————————————————————————————————————————————————–
4. ELECTRICAL CHARACTERISTICS
Note (1) The ripple voltage should be controlled fewer than 10% of V DD (Typ.) voltage.
(2) fV=60Hz, fDCLK = 78MHz, VDD = 12.0V, DC Current.
(3) Power dissipation check pattern (LCD Module only)
——————————————————————————————————————————————––—
Doc.No. LSC320AN02 Page 9 of 36 Rev.No. 06-000-G-20121228
————————————————————————————————————————————————–
5. INPUT TERMINAL PIN ASSIGNMENT
Note (1) No connection: These PINS are used only for the product of SAMSUNG.
(DO NOT CONNECT the input device to these pins.)
Note2) LVDS OPTION : If this PIN is HIGH (3.3 V) → Normal LVDS format
LOW (GND) → JEIDA LVDS format
——————————————————————————————————————————————––—
Doc.No. LSC320AN02 Page 10 of 36 Rev.No. 06-000-G-20121228
————————————————————————————————————————————————–
Note (2) Pin number which starts from the left side.
——————————————————————————————————————————————––—
Doc.No. LSC320AN02 Page 11 of 36 Rev.No. 06-000-G-20121228
————————————————————————————————————————————————–
5.2 LVDS INTERFACE
- LVDS receiver : T-con(merged)
- Data format
LVDS pin JEIDA -DATA Normal-DATA
TxIN/RxOUT0 R2 R0
TxIN/RxOUT1 R3 R1
TxIN/RxOUT2 R4 R2
TxOUT/RxIN0 TxIN/RxOUT3 R5 R3
TxIN/RxOUT4 R6 R4
TxIN/RxOUT6 R7 R5
TxIN/RxOUT7 G2 G0
TxIN/RxOUT8 G3 G1
TxIN/RxOUT9 G4 G2
TxIN/RxOUT12 G5 G3
TxOUT/RxIN1 TxIN/RxOUT13 G6 G4
TxIN/RxOUT14 G7 G5
TxIN/RxOUT15 B2 B0
TxIN/RxOUT18 B3 B1
TxIN/RxOUT19 B4 B2
TxIN/RxOUT20 B5 B3
TxIN/RxOUT21 B6 B4
TxOUT/RxIN2 TxIN/RxOUT22 B7 B5
TxIN/RxOUT26 DEN DE
TxIN/RxOUT27 R0 R6
TxIN/RxOUT5 R1 R7
TxIN/RxOUT10 G0 G6
TxOUT/RxIN3 TxIN/RxOUT11 G1 G7
TxIN/RxOUT16 B0 B6
TxIN/RxOUT17 B1 B7
——————————————————————————————————————————————––—
Doc.No. LSC320AN02 Page 12 of 36 Rev.No. 06-000-G-20121228
————————————————————————————————————————————————–
5.3 INPUT COLOR DATA MAPPING
DATA SIGNAL
GRAY
COLO DISPLAY RED GREEN BLUE SCAL
R (8bit) E
R R R R R R R R G G G G G G G G B B B B B B B B LEVEL
0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7
BLACK 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -
BLUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 -
GREEN 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 -
BASIC
COLO CYAN 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 -
R
RED 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -
MAGENT
A 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 -
YELLOW 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 -
WHITE 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 -
BLACK 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 R0
1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 R1
DARK 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 R2
GRAY ↑
SCALE : : : : : : : : : : : : : : : : : : R3~
OF : : : : : : : : : : : : : : : : : : R252
RED ↓
LIGHT 1 0 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 R253
0 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 R254
RED 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 R255
BLACK 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 G0
0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 G1
DARK 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 G2
GRAY ↑ : : : : : : : : : : : : : : : : : :
SCALE G3~
OF : : : : : : : : : : : : : : : : : : G252
GREEN ↓
LIGHT 0 0 0 0 0 0 0 0 1 0 1 1 1 1 1 1 0 0 0 0 0 0 0 0 G253
0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 G254
GREEN 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 G255
BLACK 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 B0
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 B1
DARK 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 B2
GRAY ↑
: : : : : : : : : : : : : : : : : : B3~
SCALE
OF : : : : : : : : : : : : : : : : : : B252
BLUE ↓
LIGHT 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 1 1 1 1 1 1 B253
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 B254
BLUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 B255
Note (1) Definition of gray : Rn: Red gray, Gn: Green gray, Bn: Blue gray (n=gray level)
Note (2) Input signal: 0 =Low level voltage, 1=High level voltage
——————————————————————————————————————————————––—
Doc.No. LSC320AN02 Page 13 of 36 Rev.No. 06-000-G-20121228
————————————————————————————————————————————————–
6. INTERFACE TIMING
6.1 TIMING PARAMETERS OF TIMING (Only DE Mode)
Signal Item Symbol Min. Typ. Max. Unit Note
Clock 1/TC 72 78 85 MHz -
Hsync Frequency FH 44 48 53 KHz -
Vsync FV 47 60 66 Hz -
Term for the Active display
TVD - 768 - Lines -
Vertical period
Display Total vertical TV 780 802 1000 Lines -
Active display
Term for the THD - 1366 - Clocks -
Period
Horizontal
Total
Display TH 1580 1624 1800 clocks -
Horizontal
Note) These products don’t have to receive the signal of Hsync & Vsync from the input device.
(1)Key points when testing: TTL controls the signal and the CLK at the input terminal of LVDS Tx of the system.
(2) Internal VDD = 3.3V
(3) Spread spectrum
- Modulation Frequency : 30~300KHz
* The limit of spread spectrum's range of SET in which the LCD module is assembled should be within ± 1.5 %.
——————————————————————————————————————————————––—
Doc.No. LSC320AN02 Page 14 of 36 Rev.No. 06-000-G-20121228
————————————————————————————————————————————————–
tRSRM - - 450 ps
Input data position FIN=80MHz
tRSLM -450 - - ps
——————————————————————————————————————————————––—
Doc.No. LSC320AN02 Page 15 of 36 Rev.No. 06-000-G-20121228
————————————————————————————————————————————————–
T5: The time which takes for B/L to be turned on after the signal is entered when the time is on.
T6 : The time which takes until the signal is out after BL is turned off
The condition of supply voltage to enter in the module from the external system should have the
same condition as the definition of VDD.
Apply the voltage for the lamp within the range which the LCD operates. when the back light is turned on
before the LCD is operated or when the LCD is turned off before the back light is turned off, the display
may show the abnormal screen momentarily.
While the VDD is off level, please keep the level of input signals low or keep a high impedance condition.
The figure of T4 should be measured after the module has been fully discharged between the periods
when the power is on and off.
The interface signal must not keep the high impedance condition when the power is on.
——————————————————————————————————————————————––—
Doc.No. LSC320AN02 Page 16 of 36 Rev.No. 06-000-G-20121228
ACTIVE CENTER
————————————————————————————————————————————————–
8. PACKING
8.1 CARTON
(1) Packing Form
Corrugated Card board box as shock absorber.
——————————————————————————————————————————————––—
Doc.No. LSC320AN02 Page 18 of 36 Rev.No. 06-000-G-20121228
————————————————————————————————————————————————–
8.2 MARKING
A nameplate is affixed to the specified location on each product.
——————————————————————————————————————————————––—
Doc.No. LSC320AN02 Page 19 of 36 Rev.No. 06-000-G-20121228
————————————————————————————————————————————————–
(4) Nameplate Indication
TO1
7
TO1
15
TO1
140
——————————————————————————————————————————————––—
Doc.No. LSC320AN02 Page 20 of 36 Rev.No. 06-000-G-20121228
————————————————————————————————————————————————–
9 GENERAL PRECAUTIONS
9.1 HANDLING
(a) When the panel kit and BLU kit are assembled, the panel kit and BLU kit should be attached to the set
system firmly by combining each mounted holes. Be careful not to give the mechanical stress.
(b) Be careful not to give any extra mechanical stress to the panel when designing the set, and BLU kit.
(c) Be cautious not to give any strong mechanical shock and / or any forces to the panel kit.
Applying the any forces to the panel may cause the abnormal operation or the damage to the panel kit and
the back light unit kit.
(d) Refrain from applying any forces to the source PBA and the drive IC in the process of the handling or
installing to the set. If any forces are applied to the products, it may cause damage or a malfunction in the
panel kit.
(e) Refrain from applying any forces which cause a constant shock to the back side of panel kit, the set
Design and BLU kit. If any forces are applied to the products, it may cause an abnormal display, a functional
failure and etc.
(g) Wipe off water droplets or oil immediately. If you leave the droplets for a long time on the product, a
staining or the discoloration may occur.
(h) If the surface of the polarizer is dirty, clean it using the absorbent cotton or the soft cloth.
(j) If the liquid crystal material leaks from the panel, this should be kept away from the eyes or mouth.
If this contacts to hands, legs, or clothes, you must washed it away with soap thoroughly and see a doctor
for the medical examination.
(k) Protect the panel kit and BLU Kit out of the static electricity. Otherwise the circuit IC could be damaged.
3 Equipment Ground Resistance All Equipment Ground Should be less than 1ohm.
——————————————————————————————————————————————––—
Doc.No. LSC320AN02 Page 21 of 36 Rev.No. 06-000-G-20121228
————————————————————————————————————————————————–
(l) Remove the stains with finger-stalls wearing soft gloves in order to keep the display clean in the process of
the incoming inspection and the assembly process.
(m) Do not pull or fold the source drive IC which connects to the source PBA and the panel or the gate drive
IC.
(n) Do not pull, fold or bend the source drive IC and the gate drive IC in any processes.
If not, the source drive IC could be bent one time in the process of assembling the panel Kit and the BLU
Kit.
(o) Do not adjust the variable resistor located on the panel kit and BLU kit except when adjusting the flicker.
(p) Do not touch the pins of the interface connector directly with bare hands.
(r) The protection film for the polarizer on the panel kit should be slowly peeled off just before using so that
the electrostatic charge can be minimized.
(s) The panel kit and BLU kit have high frequency circuits. The sufficient suppression to the EMI should be
done by the set manufacturers.
(t) The set of which the panel is assembled shall not be twisted. If the product is twisted, it may cause the
damage on the product.
(u) Surface Temp. of IC should be controlled less than 100℃, operating over the Temp. can cause the damage
or decrease of lifetime.
——————————————————————————————————————————————––—
Doc.No. LSC320AN02 Page 22 of 36 Rev.No. 06-000-G-20121228
————————————————————————————————————————————————–
9.2 STORAGE
The storage condition for packing
ITEM Unit Min. Max.
Storage
(℃) 5 40
Temperature
Storage
(%rH) 35 75
Humidity
Storage life 6 months
(1) The storage room should provide good ventilation and temperature control.
(2) Products should not be placed on the floor, but on the Pallet away from a wall.
(3) Prevent products from direct sunlight, moisture nor water; Be cautious of a buildup of
condensation.
(4) Avoid other hazardous environment while storing goods.
Storage
(5) If products delivered or kept in conditions of the recommended temperature or humidity,
Condition
we recommend you leave them at a circumstance which is shown in the following table.
9.3 OPERATION
(a) Do not connect or disconnect the FFC cable during the "Power On" condition.
(b) Power supply should be always turned on and off by the "Power on/off sequence"
(c) The module has high frequency circuits. The sufficient suppression to the electromagnetic interference
should be done by the system manufacturers. The grounding and shielding methods is important to minimize
the interference.
(d) The cables between TV SET connector and Control PBA interface cable should be connected directly to
have a minimized length. A longer cable between TV SET connector and Control PBA interface cable maybe
operate abnormal display
(e) Recommend to age for over 1 hour at least in the state, which the product is driving initially to stabilize the
characteristic of the initial TFT.
(f) Response time depends on the temperature.( In Lower temperature, it becomes longer)
——————————————————————————————————————————————––—
Doc.No. LSC320AN02 Page 23 of 36 Rev.No. 06-000-G-20121228
————————————————————————————————————————————————–
9.4 OPERATION CONDITION GUIDE
(a) The LCD product shall be operated under normal conditions.
The normal condition is defined as below;
- Temperature : 20± 15℃
- Humidity : 55± 20%
- Display pattern : continually changing pattern (Not stationary)
(b) If the product will be used under extreme conditions such as under the high temperature, humidity,
display patterns or the operation time etc.., it is strongly recommended to contact SDC for the advice about
the application of engineering . Otherwise, its reliability and the function may not be guaranteed. Extreme
conditions are commonly found at airports, transit stations, banks, stock markets, and controlling systems.
Default : 0V
Vcom tunning : 3.3V
27 TCON_WP EN
(Shouldn’t be communicated with I2C device as output level
“5V”)
(2) Flicker should be tuned by correct method according to gamma IC type of each model and
(LSC400HM06 – “Genie Type”)
(3) Flicker should be adjusted the pattern, where are displayed alternately at green sub-pixel. (Green 1*1 Dot
Pattern)
——————————————————————————————————————————————––—
Doc.No. LSC320AN02 Page 24 of 36 Rev.No. 06-000-G-20121228
————————————————————————————————————————————————–
9.6 OTHERS
(a) The ultra-violet ray filter is necessary for the outdoor operation.
(b) Avoid the condensation of water which may result in the improper operation of product or the
disconnection of
electrode.
(c) Do not exceed the limit on the absolute maximum rating. (For example, the supply voltage variation, the
input voltage variation, the variation in content of parts and environmental temperature, and so on) If not,
panel may be damaged.
(d) If the module keeps displaying the same pattern for a long period of time, the image may be remained to
the screen. To avoid the image sticking, it is recommended to use a screen saver.
(e) This Panel has its circuitry of PCB's on the rear side, so it should be handled carefully in order for a force
not to be applied.
(f) Please contact the SDC in advance when the same pattern is displayed for a long time
——————————————————————————————————————————————––—
Doc.No. LSC320AN02 Page 25 of 36 Rev.No. 06-000-G-20121228
————————————————————————————————————————————————–
10. SPECIAL PRECAUSTIONS
No Component Expected cause
.
Prevent the panel from breaking by assigning gaps between the panel and the upholding part for panel on the drawing
1 Upholding part for for the upholding part for panel.
panel Refer to the (a), (b), (c) of 3-1 for the design of BLU.
The shape of the Design the upholding part for panel to fit to the panel appropriately when designing the BLU since the shape of the
2 upholding part for upholding part for panel may damage the panel.
panel Refer to the (a), (b), (c) of 3-1 for the design of BLU.
The edge of Design the edge of panel to have a sufficient space with the upholding part for panel when designing the BLU since the
3 upholding part for edge of the upholding part for panel may damage the panel when assembling the panel and BLU.
panel Refer to the (a), (b), (c) of 3-1 for the design of BLU.
Place the upholding part for the panel in order for the shape of mold, which contacts with the panel not to interfere
4 Upholding part for with the area of panel.
panel Refer to the (a), (b), (c) of 3-1 for the design of BLU.
Design the BLU in order for the COF not to contain the lead crack resulted from the tensioned COF created when the
5 Drive IC product is twisted if the space between the D-IC COF and the middle mold isn't sufficient.
Refer to the (a), (b), (c),(d),(e),(f), and (g)of 3-2 for the design of BLU.
Design the BLU in order for the product not to contain the lead crack resulted from the tensioned COF caused under the
6 Drive IC condition, which the product is twisted by fixing the source PCB.
Refer to the (a), (b), (c),(d),(e),(f), and (g)of 3-2 for the design of BLU.
1) The temperature of each part of product suggested by our company and the second vendor shall meet the standard
IC of temperature, which is recommended not to be exceeded by our company when the product is affected under the
7 component various temperature ranges.
Apply over 1mm long separation distance stated in the safety standard between the electric part and each conductor.
(Apply the rated separation distance when insulating.)
8 Thermal pad Apply the thermal pad in a designated size to the product as a measure to lower the temperature of heat in order for
each part to use the rated temperature.
The surrounding area of the POL shall be treated with an electrification treatment since the external ESD may cause a
9 POL phenomenon, which the POL is coming off.
In addition, the GND portion of source PBA shall be grounded.
10 PBA The GND portion of each PBA shall be contacted with the GND portion of BLU.
Refer to the (a) and (b) of 3-3 for the design of BLU.
11 Circuit The standardized approval from the client is required since the EMI is executed by a client.
Our company can only measure the reference since the client measures the BLU.
12 The height of Design the BLU with considering the maximum height of parts, which our company suggests.
component
13 Between the FFC and Design the instrument with considering the length between the FFC and the control PBA.
the C-PBA (The marginal minimum length of 5mm or 8mm is required.)
The surface temperature of panel shall be maintained within 0℃ and 45℃ when the external ambient temperature is at
14 Panel
25℃. (Design the BLU with considering the increase of the temperature in the panel by the LED, CCFL, and etc.)
15 Aging Recommend to age for over 1 hour at least in the state, which the product is driving initially to stabilize the
characteristic of the initial TFT.
16 The attachment of The additional confirmation by our company is required If the attachment of gasket to the S-PBA of our company is
gasket required.(To fix the S-PBA or the EMI)
Design the top chassis and the driver IC to be contacted by placing the shape of emboss inside the top chassis as a
17 Drive IC measure to prevent the driver IC from heating. The size of emboss shall be designed in larger size than the size of IC
inside the film of the driver IC.
Refer to the (a), (b), (c),(d),(e),(f), and (g)of 3-2 for the design of BLU.
18 The prohibited Design the BLU in order for the BLU not to interfere with the area, where the control PBA and the source PBA are
bandwidth located densely according to the drawing for the BLU from our company.
The material, which contacts with the bottom side of S-PBA which has a pattern shall be non-conducting material or
19 S-PBA shall be insulated.
——————————————————————————————————————————————––—
Doc.No. LSC320AN02 Page 26 of 36 Rev.No. 06-000-G-20121228
————————————————————————————————————————————————–
APPENDIX – RECOMMENDATION FOR THE BLU DESIGN
1. The schematic of panel
Polaroid Film ②
TFT Glass ④
Source IC ⑤
Gate IC ⑥
Source PBA ⑦
FFC ⑧
——————————————————————————————————————————————––—
Doc.No. LSC320AN02 Page 27 of 36 Rev.No. 06-000-G-20121228
————————————————————————————————————————————————–
2. The tolerance of panel assembly
X1 ± 0.3
Glass Cutting
Y1 ± 0.3
——————————————————————————————————————————————––—
Doc.No. LSC320AN02 Page 28 of 36 Rev.No. 06-000-G-20121228
————————————————————————————————————————————————–
3. The guide for the mechanical design
When the guiding part is made of plastic resin, the gap between the panel and the guiding structure
should be considered when you design. The shrinkage under the situation which the temperatures
change causes the light leakage. For your reference, it is recommended to have a total gap between
the panel and the guide structure as below (When the resin is composed of the PC and the 15% of
G/F.)
It is recommended to follow the dimension and the shape of the guiding structure stated as below
since the distortion of guiding parts can cause the light leakage
——————————————————————————————————————————————––—
Doc.No. LSC320AN02 Page 29 of 36 Rev.No. 06-000-G-20121228
————————————————————————————————————————————————–
(b) When the panel guide point is designed at the edge of the panel, the points in the corner
shall not be designed to be contacted with the other parts in order to avoid the crack on the
panel caused by the burr of the panel.
(c) It is recommended to avoid placing the ribs as shown below since the panel damage with
the unstable design can be easily happened under the external force.
-. The sharp or the round shape near the panel shall be changed to a flat shape, such as the
shape of screw point, the gate point, and etc.
-. It is recommended to keep the gap between the panel guides and ribs over 1mm in the
worst conditions.
(※ The suggested dimension does not guarantee the quality of the products.)
-. The gap between the panel guide and the front cover (or the front chassis) should be a
zero in Z-direction to avoid the being broken in the panel caused by being stuck between
the gap.
——————————————————————————————————————————————––—
Doc.No. LSC320AN02 Page 30 of 36 Rev.No. 06-000-G-20121228
————————————————————————————————————————————————–
(b) It is recommended to secure the sufficient gap between the COF and the other parts when
designing the product since the lack of gap between the COF and the other parts can cause
the damage in the COF such as the lead crack under the condition which the product is
twisted.
(※ The space over 3.0mm for moving is recommended, but the quality of products is not
guaranteed.)
(c) The temperature of the surface of Drive-IC should be less than 100℃
——————————————————————————————————————————————––—
Doc.No. LSC320AN02 Page 31 of 36 Rev.No. 06-000-G-20121228
————————————————————————————————————————————————–
(d) The sufficient space for the COF and the Drive IC should be prepared including the worst
condition to prevent the damage on Drive-IC from the external force.
-. If the panel is placed to the upper part of the mold, it is recommended to keep the gap
between the mold and the front cover or the mold and the top chassis by adding the rib
between the COF and COF.
-. Design the gap between the rib and the cover to maintain the space for the protection of COF
as small as possible
——————————————————————————————————————————————––—
Doc.No. LSC320AN02 Page 32 of 36 Rev.No. 06-000-G-20121228
————————————————————————————————————————————————–
(e) When metal parts are assembled next to the Drive-IC, the metal part should be insulated to
avoid the damage on IC from the static electricity.
(f) If the length of COF is designed to be short, the lead crack can be occurred by applying the
tension on the COF due to the being shaking of the product.
(g) It is recommended to design source PCB can be easily moved to the direction of each axis in
order for the tension not to be applied to the edge of COF under vibrating condition, such as
transportation of the product.
——————————————————————————————————————————————––—
Doc.No. LSC320AN02 Page 33 of 36 Rev.No. 06-000-G-20121228
————————————————————————————————————————————————–
3.3 The control PBA and the Source PBA
(a) The gaps between the source PBA and the other parts and the control PBA and other parts
should be considered to avoid the damage on electrical parts by the static electricity and the
external forces. If the material of shielding part is metal, the insulation method is
recommended.
(b) Confirm the status of insulation tape since the inappropriately attached insulation tape can
cause the damage on the parts of product if the insulation tape for the insulation of part of
PBA is attached inconsecutively due to the inappropriate design or the error occurred during
the process.
——————————————————————————————————————————————––—
Doc.No. LSC320AN02 Page 34 of 36 Rev.No. 06-000-G-20121228
————————————————————————————————————————————————–
3. 4 The 4-Corner and the cloudy light leakage
(a) It is recommended to follow the method delineated in the picture below for designing
since the distortion on panel and the sharp increase of the temperature gradient in the
surface of panel can cause the light leakage.
-. Place the strong beads at the corner point to control the flatness of the panel.
-. The heat sinking plane in the lower parts shall contact with the bottom chassis.
——————————————————————————————————————————————––—
Doc.No. LSC320AN02 Page 35 of 36 Rev.No. 06-000-G-20121228
————————————————————————————————————————————————–
3.5 Others
(a) The corrosion of the source PBA
Be cautious when selecting the specification of tape or designing the product since the
corrosion of the parts of circuit caused by the overuse of the glass cleaner of the end user
may cause the occurrence of the abnormalities in the screen, if the model is the reversed
product which has the source PBA designed at the 90˚.
——————————————————————————————————————————————––—
Doc.No. LSC320AN02 Page 36 of 36 Rev.No. 06-000-G-20121228