Data Sheet Dornier Medilas D LiteBeam+

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Dornier

Medilas D LiteBeam+
S P E C I F I C A T I O N S H E E T

W E ’ R E A L L A B O U T P E O P L E.
Dornier
Medilas D LiteBeam+
Technical Data
Laser Type Diode
Wavelength 940 nm
Application Modes Standard Impulse Fibertom
Laser Power 2 – 30 W 2 – 35 W 2 – 30 W
adjustable 1 W steps – 1 W steps
Fluence 10-998 J/cm2
adjustable – in steps of 2 –
Pulse Duration 10 ms – 10 s, CW 10 ms – 200 ms CW
Pulse Interval 10 ms – 10 s 200 ms – 2 s –
Pulse Repetition 0.05 – 50 Hz 0.25 – 5 Hz –
Aiming Beam Red, 635 nm, 0 -1 mW adjustable, constant or
intermittent operation
Laser Warning Signal Optical,
Acoustical, volume adjustable
Treatment Record # of pulses, energy, exposure time
Power Supply 115 – 230 V
50/60 Hz
8 A single phase
Weight 11.5 kg (25 lbs.)
Dimensions (D x W x H) Box: 38 cm x 29.5 cm x 19 cm (15” x 11.5” x 7.5”)
Box with screen and handle: 46.5 cm x 29.5 cm x 30.5 cm (18.5” x 11.5” x 12”)
Laser Cooling System Air cooling
Foot Switch Pneumatic
Standards IEC 60601, IEC 60825, European Medical Device
Directive, Device Protection Class 1, BF

Available Accessories Application modes Features


• Disposable 400 and 600 µm bare • In standard mode, the laser is used • Dornier’s lightguide protection
tip lightguides in Continuous Wave (CW) or inter- system (LPS) automatically turns
mittent operation for coagulation, off the laser if light flashes originating
• Resterilizable 400 and 600 µm vaporization and ablation in surgical from excessive heat at the fiber tip
bare tip lightguides applications. preventing damage to the fiber and
• Angiospot handpiece for the reducing the risk of vein perforations.
• The impulse mode is primarily used
treatment of vascular lesions. with the transcutaneous handpiece • The system stores 25 protocols
for dermatologic applications. which can be recalled for quick,
easy set-up. Pre-programmed treat-
• The fibertom mode enables uniform ment suggestions are included.
cutting by ensuring the temperature
of the fiber tip remains within • The intuitive, high resolution color
set limits. touch screen display is easy to use
for maximum operator convenience.
• Dose mode automatically discontin-
ues laser firing once a preset dose • The patented fibertom system controls
value is reached. Dose value is the temperature at the fiber tip during
adjustable and can be set based on cutting which allows fine tissue
energy, exposure time and number incisions with minimal carbonization
of pulses. and also prevents destructions at
the fiber tip

VISIBLE AND INVISIBLE LASER RADIATION


AVOID EYE OR SKIN EXPOSURE W E ’ R E A L L A B O U T P E O P L E .
TO DIRECT OR SCATTERED RADIATION
CLASS 4 LASER PRODUCT (IEC60825-I:2001-01)

www.dornier.com
DMT014-02/07