Manual Partial Discharge PD Detector PD
Manual Partial Discharge PD Detector PD
CN
HCL2010-M
Pioneer on Interference discriminate logic anti-interference mode
IEC60270, IEC60885-3
HCL2010-M manual partial discharge tester is special designed with wide measuring range and high
precision. The PD tester adopt balance method principle. The function of attenuation on space
interference and power supply interference is strength. Discharging repeat rate is digit measuring, the
accuracy is highly improved. Easy operating, convenient for wide User. It good selection for PD tester with
low budget.
Application:
The partial discharge tester suitable for motor, transformer, instrument transformer, cable, bushing,
Applied Standard
• IEC60885-3 《Test methods for partial discharge measurements on lengths of extruded power
cables》
• IEC60060-1&2
• IEC-885
• IEEE Std.4
Application Scope
Power Cable
Project HCL2010
Interference discriminate logic customize), continuous four ( or above four ) test voltage cycle, “effective”
Frequency 50, 100, 200, 400Hz, each 30 is one grade, rotate 360 degree.
Ellipsoid scan time base (T.B.)
Absorb power <1VA.
Pulse peak value meter 31/2 digit LED display, error < 5% F.S
Test voltage meter Measuring range:100kV (expandable) digit display, error <3% F.S
Linearity(10-100% FS) 1%
z The convenient PD setting device, enable reading the partial discharge value directly
on the interface
z Pulse peak value meter sampling and digital voltmeter matching well with each other,
high accuracy on measuring.
z The discharge quantity can be record (Repeat rate n), matching up with other
component, can get the relationship between q—n,n—ψ,q—ψ. ( q – discharge level,
ψ phase angle )
z Digital display, different parameters are visible.
z Small volume, light weight, suitable for testing in power institute or workshop or high
voltage research.
z High sensitivity
Other parameter:
Dimension: 500x490x200 mm (W x L x H)
Weight: 15kg