0% found this document useful (0 votes)
478 views5 pages

Sample Questions

The document provides specifications and standards for concrete construction projects in Saudi Arabia. It includes requirements for materials, mix designs, placement, curing, and testing of concrete. Maximum aggregate size is 50mm, required slump is 100mm±25mm, and water-cement ratio must be 0.4-0.6 depending on the application. Concrete compressive strength must reach 28MPa for structural elements and 14MPa for other uses after 28 days of curing. Reinforcing steel must have a minimum tensile strength of 422MPa. Quality control, testing, and inspection are required according to standards from ACI, ASTM, SASO, and Saudi Aramco.

Uploaded by

mohd khaja
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
478 views5 pages

Sample Questions

The document provides specifications and standards for concrete construction projects in Saudi Arabia. It includes requirements for materials, mix designs, placement, curing, and testing of concrete. Maximum aggregate size is 50mm, required slump is 100mm±25mm, and water-cement ratio must be 0.4-0.6 depending on the application. Concrete compressive strength must reach 28MPa for structural elements and 14MPa for other uses after 28 days of curing. Reinforcing steel must have a minimum tensile strength of 422MPa. Quality control, testing, and inspection are required according to standards from ACI, ASTM, SASO, and Saudi Aramco.

Uploaded by

mohd khaja
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 5

SAMPLE QUESTIONS:

Backfill materials for loose soil with machine compactor(thickness)? 200mm

Maximum size of select fill materials? 50mm

Compressive strength of structural concrete sample? 28Mpa

Tensile strength of steelbars in aramco projects? 422Mpa

The maximum concrete temperature. 32 Degrees C

Thickness of plastic sheet use for curing? .15 mm

Required slump for Saudi aramco projects? 100mm+- 25mm

Aspalt compaction ratio of marshall density? 96%

Min. diameter size of anchor bolt? 20mm

Moisture content of concrete before compaction? Less than 4%

Proper moisture of soil before coating? +- 3% of density

Drum revolution of concrete? 300

Min. no of days for water curing? 7 days

Max.height of concrete free fall in placement?] 1 meter

Aparatus for concrete moisture field test before coating? Elcometer probes

Q.C. – operational techniques and activities that are use to fulfill the requirements for
quality.
Q.A. - Implemented planned and systematic activities within the quality systems and
demonstration as needed to provide adequate confidence that an entity will fulfill
requirements for quality.
Method of Statement consist:
1. Installation
2. Quality Control/Quality all
3. Manufacturer Representative attend during the installation
4. Certification of personal executing the work.

INDUSTRY CODES AND STANDARDS:


ACI212.3R-CHEMICAL ADDMIXTURES FOR CONCRETE

ACI302-1R-GUIDE FOR CONCRETE FLOOR AND SLAB

ACI305R/ACI 308-CONCRETE CURING/ HOT WEATHER CONCRETING

ACI347 R- FORMWORK

ACI318-BUILDING CODE FOR STRUCTURAL CONCRETE

ASTMC39-CONCRETE SAMPLING

ASTMC90-CONCRETE MASONRY UNITS

ASTMD2922-NUCLEAR METHOD FOR FDT

ACI347R-FORMWORKS FOR CONCRETE

ACI304R-PUMPING METHOD FOR PLACEMENT OF CONCRETE

ASTMC494- STANDARD SPECS FOR CHEMICAL ADMIXTURES FOR CONCRETE.

ASTM C150- SPECS. FOR PORTLAND CEMENT

ASTM C91-MASONRY CEMENT

ASTMC144-AGGREGATE FOR MASONRY MORTAR

ASTMC136- SIEVE ANALYSIS OF FINE& COURSE AGGREGATES

ASTMA884-COATED WIRE&WELDED WIRE FABRIC USED FOR REINFORCEMENT SHALL BE FBEC.

ACI504R-GUIDE TO SEALING JOINTS IN CONCRETE STRUCTURES

ACI515.1R-GUIDE TO USE OF WATERPROOFING,DAMPROOFING,PROTECTIVE AND DECORATIVE


BARRIER SYSTEMS FOR CONCRETE.

ACI360R-DESIGN OF SLAB ON GRADE

ACI212.3R- CHEMICAL ADMIXTURES FOR CONCRETE

ACI301-05-SPECIFICATIONS FOR STRUCTURAL CONCRETE

ASTMA775-STANDARD SPECIFICATIONS FOR EPOXY- COATED REINFORCING BARS.

ASTMA884-STANDARD SPECIFICATIONS FOR EPOXY COATED STEEL WIRE AND WELDED WIRE
FABRIC FOR REINFORCEMENT
ASTMA615- STANDARD SPECS. FOR DEFORMED AND PALIN BILLET STEEL BAR FOR CONCRETE
REINFORCEMENT.

SAUDI ARAMCO STANDARDS:

SAES-Q-001-CRITERIA FOR DESIGN AND CONTRUCTIONS OF CONCRETE STRUCTURE.

SAES-Q-005-CONCRETE FOUNDATION

SAES-Q-006-CONCRETE ASPHALT PAVEMENT

SAES-Q-009-RETAINING WALL

SAES-Q-010-NON-SHRINK GROUT

SAES-H-003-COATING OF CONCRETE SURFACE

SAES-H-101-APROVED PROTECTIVE COATING SYSTEMS.

SAES-M-100- CODE FOR BUILDING CONSTRUCTION

SAES-A-114- SPECIFICATIONS FOR BACKFILL AND EXCAVATION

SAUDI ARAMCO INSPECTION CHECKLIST:

SAIC-Q-001- CONCRETE SAMPLING

SAIC-A-1004-5- PROPER HANDLING AND STORAGE OF FBEC

SAIC-Q-1007-PROPER HANDLING AND STORAGE OF FBEC

SAIC-Q-1009-INSPECTION OF MASONRY INSTALLATION

SAIC-Q-1013-INSPECTION OF INSTALLATION OF REBARS

SAIC-Q-1015-FORMWORK STRIPPING

SAIC-Q-1060- CONCRETE POURING AND SAMPLING

SAUDI ARABIA STANDARD ORGANIZATION:

SASO SSA 2- STEEL BARS FOR REINFORCEMENT CONCRETE

SASO SSA 224- PORTLAND CEMENT, ORDINARY AND RAPID HARDENING

SAUDI ARAMCO MATERIALS SYSTEMS SPECIFICATIONS:


09 SAMSS-106-MATERIALS FOR FBEC STEEL REINFORCEMENT

09 SAMSS-088- AGGREGATES FOR CONCRETE

09 SAMSS-075- CAULKING COMPOUND(JOINT SEALANT)

09 SAMSS-097-READY MIXED PORTLAND CEMENT CONCRETE

CONCRETE:

TEMPERATURE MAX: 32 DEG. CENTEGRADE FOR STRUCTURAL

: 30 DEG. CENTEGRADE FOR MORTAR

: 23 +-3 DEG. CENTEGRADE FOR GROUT

COMPRESSIVE STRENGTH:

4000 PSI or 28 Mpa : STRUCTURAL CONCRETE, RING WALLS @ 28 DAYS

2000 PSI or 14Mpa : LEAN CONCRETE , MORTAR @28 DAYS

5000 PSI or 35Mpa : WATER RETAINING STRUCTURE,GROUT @28 DAYS

500 PSI or 3.5 Mpa : NON LOAD BEARING CMU

1500PSI or 10.5 Mpa : LOAD BEARING CMU

WATER CEMENT RATIO:

0.4 – STRUCTURAL CONCRETE

0.6 - NON STRUCTURAL CONCRETE

CEMENT CONTENT:

STRUC TURAL CONCRETE- MINIMUM 350Kg/m³

-MAXIMUM 370Kg/ m³

NON STRUCUTRAL CONCRETE-MINIMUM 250 Kg/ m³

CEMENT TYPE: ABOVE GRADE/ NOT EXPOSE TO EARTH – OPC TYPE 1

BELOW GRADE/EXPOSE TO EARTH- TYPE V SRC


WATER
TDS MAX USE FOR CONCRETE MIXED- 500 PPM

TDS MAX USE FOR CURING CONCRETE-1000 PPM

PH VALUE FOR CONCRETE MIXED: 6-8

PH VALUE FOR CURING : 7-8

MINIMUM DAYS FOR CURING OF CONCRETE : 7 DAYS

TENSILE STRENGTH OF FBEC: 422 Mpa.

TENSILE STRENGTH OF WWF: 420 Mpa.