0% found this document useful (0 votes)
719 views3 pages

Lintel Design

The lintel beam has dimensions of 230x230 mm and is reinforced with 2 bars of 12 mm diameter on each side and 2 bars of 10 mm diameter on the top and bottom. The loading on the beam includes a brick wall load of 3.04 kN and the self-weight of the beam. The design calculations show that the beam has an ultimate positive bending capacity of 11.5 kNm and ultimate shear capacities of 21.0 kN without shear reinforcement and 38.8 kN with the minimum shear reinforcement of 8 mm bars at 625 mm spacing.

Uploaded by

Prashant Huddar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
719 views3 pages

Lintel Design

The lintel beam has dimensions of 230x230 mm and is reinforced with 2 bars of 12 mm diameter on each side and 2 bars of 10 mm diameter on the top and bottom. The loading on the beam includes a brick wall load of 3.04 kN and the self-weight of the beam. The design calculations show that the beam has an ultimate positive bending capacity of 11.5 kNm and ultimate shear capacities of 21.0 kN without shear reinforcement and 38.8 kN with the minimum shear reinforcement of 8 mm bars at 625 mm spacing.

Uploaded by

Prashant Huddar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Lintel Beam:

 Dimensions and arrangement

 Material properties: M25 (fck = 25MPa) and Fe500 (fy = 500 MPa)
 Clear cover considered is 40 mm
 Load Combination considered is 1.4 DL
 Lintel beam 230 X 230
 Summary:
Reinforcement 2-N12 at top and bottom and 1-N12 at each side
Beam Forces:
B 230 X 230 mm:

Mx V
Parameters Reinforcement
( kN.m ) ( kN )
2N10 – Top and Bottom each
Capacity B 0.23 x 0.23m 11.5 21
2N10 – Top and Bottom each
Actual Loads B 0.23 x 0.23m 1.86 4.05

 Loading calculations -
Height of wall above lintel = 1.6 m (assumed)
Length of the lintel = clear span + 0.3 = 0.82 + 0.3 = 1.12 m
Brick density = 20 kN/m3
Concrete density = 25 kN/m3
Brick Wall

Lintel Beam
150 820 mm 150

Masonary load =
W1 = 0.5 (l x l.Sin60 x t x b)
W1 = 0.5 x 1.12 x (1.12.Sin60) x 0.28 x 20
W1 = 3.04 kN
Moment due to Brick = W1.l / 6
M1 = 4.89 x 1.12 / 6 =0.91 kN.m
Lintel Self- Wt =
W2 = 0.28 x 0.3 x 25
W2 = 2.1 kN/m
Moment due to Self-wt = W2 x l2/8
M2 = 2.1 x 1.122 / 8 =0.329 kN.m
Total BM = M1 + M2 = 1.239 kN.m
Factored BM, Mu= 1.5 x M = 1.86 kN.m
Shear Force,
V = wl/2 + W/2
= (2.1 x 1.12 /2) + (3.04/2)
= 2.69 kN
Vu = 1.5 x 2.69 = 4.05 kN

 Design of lintel –

The lintel is designed as the beam using AS 3600 code.

Please see the below design for the more details.


Lintel beam Design:
dsc = 40 mm
f Bending = 0.8
f Shear = 0.7
f'c = 25 MPa
f'cf = 3.000 MPa
fsy = 500 MPa
eu = 0.003 (Conc. Strain CL8.1.2.2) dst = 185 mm D=
Es = 200000 MPa 230 mm
esy = 0.0025 (Steel Strain limit)

BENDING CALCULATIONS
Exposure Classification : A2 0.25%
b= 230 mm
Ast > 106 mm 2 Min. longitunial reinf. OK
Effective depth for +ve moment dst = 185 mm
g = 1.05 - 0.007f'c with the limits 0.67 to 0.87 Compression Steel
g = 0.87 2 bars of 10 mm dia.
Asc = 157.1 mm
2

α2 = 1.0 - 0.003f'c with the limits 0.67 to 0.87 Tension Steel

α2 = 0.87 2 bars of 10 mm dia.


Ast = 157.1 mm
2

Side rein. Steel


C = 78.54 kN 1 bars of 12 mm dia.
Ast = 113.1 mm
2

SHEAR CALCULATIONS
T = 78.54 kN Ultimate Shear Strength (excl. shear reinf) of reinf. Beam:
Vuc = b1b2b3bvdo(Astf'c/bvdo)1/3 CL8.2.7.1
Ductility of beam section, Vuc = 29.93 kN b 1 = 1.1(1.6 - do/1000) > 1.1
fVuc = 20.95 kN b1 = 1.557
b2 = 1.0 ...for N* = 0
ku = 0.022 ku < 0.4, Section is Ductile, therefore OK b3 = 1.0

Calculate M u , Ultimate Shear Strength (min. shear reinf) of Beam:


Vumin = Vuc + 0.6 bv do
Vumin = 55.5 kN
Mu = 14.39 kNm fVumin = 38.8 kN
fMu = 11.51 kNm ........ +ve moment capacity
Min. Shear Reinforcement :

SUMMARY
Positive Bending Moment Capacity Shear rein. Bar size = 8 mm Legs = 2
A sv.min prov. = 100.48 Spacing Req. = 625 mm
fMu = 11.5 kNm
Hence provide #8mm bar at 625mm c/c as min. shear reinforcement
Shear capacity without shear reinforcement

fVuc = 21.0 kN Shear reinforcement required :

Shear rein. Bar size = 8 mm Legs = 2


Shear capacity with minimum shear reinforcement A sv pro. = 100.48 Spacing Req. = 200 mm

fVumin = 38.8 kN

Shear capacity for shear reinforcement Vus = 46.5 kN

fVucs = 53.5 Vuc + Vus


Vucs =
kN
Vucs = 76.40 kN
fVucs = 53.48 kN