0% found this document useful (0 votes)
1K views9 pages

LT Panel

The document discusses the design, supply, installation, testing and commissioning of various electrical panels and switchgears for a building project. It includes specifications for 4 feeder pillar panels, common area electrical panels including meter panels, main panels and utility panels. Quantities and descriptions are provided for 51 different panel types.

Uploaded by

ravi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views9 pages

LT Panel

The document discusses the design, supply, installation, testing and commissioning of various electrical panels and switchgears for a building project. It includes specifications for 4 feeder pillar panels, common area electrical panels including meter panels, main panels and utility panels. Quantities and descriptions are provided for 51 different panel types.

Uploaded by

ravi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 9

SR. NO.

DESCRIPTION OF ITEM QTY UNIT

HT & INFRA Electrical

D FEEDER PILLER

Design, Assembling, Supply, Installation, Testing and Commissioning of


following feeder pillar and swithgears suitable for 415 Volts, 3 phase 4 wire,
50 Hz power distribution system. In conjunction with general specifications
following points should also be considered and adhered to.

1)All the Switchboards shall be Indoor type, dust and vermin proof type
compartmentalised design maintaining IP 54 degree of protection.
2)Switchboards shall be free standing floor mounted or wall mounted as
required.
3)All the Switchboards shall be of compartmenttalised with entire fabrication
in 14 Guage Sheet Steel and Powder Coated with Siemens gray paint shade
no. RAL-7032 of IS-5.
4)All hinged door shall be earthed through 2.5 sq mm tinned copper wire.
Doors shall be pad locking type whereas for MCCB compartments they
should be openable only in switch OFF mode.
5)All the busbars and links shall be of copper with colour coded heat
shrinkable insulating sleeves. Separate earth busbars shall be provided
along the length of the switchboards.
6)Adequate space for cable entries and terminations shall be provided
refering SLDs. Cable entries can be either from the top or bottom as
required.

1 FEEDER PILLER PANEL (as per schematic) 4 No

Incoming-

1000 Amps, 415 Volts, TPN, 50 KA, ACB, with inbuilt thermal releases for
Over Current, Short Circuit,Under voltage protections,Earth fault. Panel
compartment shall be fitted with following:

i R, Y & B Phase indicating lamps protected by 2 Amps MCBs.


ii ON, OFF, Trip indicating lamps protected by 2 Amps MCBs.
0 -1000 Amps, 96 x 96 sq.mm digital ammeter with 3 Nos.250 / 5 amps, 15
iii
VA Class I CT’s. and Ammeter Selector Switch
0 - 500 Volts, 96 x 96 sq.mm digital voltmeter with Voltmeter Selector Switch
iv
and protected by 2 amp TP MCB’s

Bus Bar -
1250 Amps, 415 Volts, TPN,50 KA rating, uniform Aluminium busbars with
color coded heat shrinkable insulating sleeves.

Outgoing-
i 1000 Amps.415 Volts,TPN MCCB- 1nos with ON ,OFF,TRIP indication
ii 200 Amps.415 Volts,TPN,MCCB- 2 nos with ON ,OFF,TRIP indication
iii 250 Amps.415 Volts,TPN,MCCB- 1nos with ON ,OFF,TRIP indication

2 FEEDER PILLER PANEL (as per schematic) 1 No

Incoming-

1000 Amps, 415 Volts, TPN, 50 KA, ACB, with inbuilt thermal releases for
Over Current, Short Circuit,Under voltage protections,Earth fault. Panel
compartment shall be fitted with following:

i R, Y & B Phase indicating lamps protected by 2 Amps MCBs.


ii ON, OFF, Trip indicating lamps protected by 2 Amps MCBs.
0 -1000 Amps, 96 x 96 sq.mm digital ammeter with 3 Nos.250 / 5 amps, 15
iii
VA Class I CT’s. and Ammeter Selector Switch
0 - 500 Volts, 96 x 96 sq.mm digital voltmeter with Voltmeter Selector Switch
iv
and protected by 2 amp TP MCB’s

Bus Bar -
1250 Amps, 415 Volts, TPN,50 KA rating, uniform Aluminium busbars with
color coded heat shrinkable insulating sleeves.

Outgoing-

i 250 Amps.415 Volts,TPN,MCCB- 1nos with ON ,OFF,TRIP indication


ii 630 Amps.415 Volts,TPN,MCCB- 2nos with ON ,OFF,TRIP indication
iii 800 Amps.415 Volts,TPN,MCCB- 1nos with ON ,OFF,TRIP indication

3 FEEDER PILLER PANEL (as per schematic) 1 No

Incoming-

1000 Amps, 415 Volts, TPN, 50 KA, ACB, with inbuilt thermal releases for
Over Current, Short Circuit,Under voltage protections,Earth fault. Panel
compartment shall be fitted with following:

i R, Y & B Phase indicating lamps protected by 2 Amps MCBs.


ii ON, OFF, Trip indicating lamps protected by 2 Amps MCBs.
0 -1000 Amps, 96 x 96 sq.mm digital ammeter with 3 Nos.250 / 5 amps, 15
iii
VA Class I CT’s. and Ammeter Selector Switch
0 - 500 Volts, 96 x 96 sq.mm digital voltmeter with Voltmeter Selector Switch
iv
and protected by 2 amp TP MCB’s

Bus Bar -
1250 Amps, 415 Volts, TPN,50 KA rating, uniform Aluminium busbars with
color coded heat shrinkable insulating sleeves.
Outgoing-

i 1000 Amps.415 Volts,TPN,MCCB- 1nos with ON ,OFF,TRIP indication-3 no

ii 200 Amps.415 Volts,TPN,MCCB- 3nos with ON ,OFF,TRIP indication-3 no

COMMON AREA Electrical

B L.V SWITCHBOARDS

Design, Assembling, Supply, Installation, Testing and Commissioning of


following LV Switchboards and Swithgears suitable for 415 Volts, 3 phase 4
wire, 50 Hz power distribution system. In conjunction with general
specifications following points should also be considered and adhered to.

1) The Switchboards shall be dust and vermin proof type compartmentalised


design maintaining IP 54 degree of protection.
2) Switchboards shall be free standing floor mounted or wall mounted as
required.
3) All the Switchboards shall be of compartmenttalised with entire fabrication
in 14 Guage Sheet Steel and Powder Coated with Siemens gray paint shade
no. RAL-7032 of IS-5.
4) All hinged door shall be earthed through 2.5 sq mm tinned copper wire.
Doors shall be pad locking type whereas for MCCB compartments they
should be openable only in switch OFF mode.
5) All the busbars and links shall be of copper with colour coded heat
shrinkable insulating sleeves. Separate earth busbars shall be provided
along the length of the switchboards.
6) Adequate space for cable entries and terminations shall be provided
refering SLDs. Cable entries can be either from the top or bottom as
required.

7).All Panel shall be as per Single line diagram and technical specifications.

1 T1 MAIN PANEL as per schematic 1 No


2 T2 MAIN PANEL as per schematic 1 No
3 T3 MAIN PANEL as per schematic 1 No
4 T4 MAIN PANEL as per schematic 1 No
5 T5 MAIN PANEL as per schematic 1 No
6 T6 MAIN PANEL as per schematic 1 No
7 LIG MAIN PANEL as per schematic 1 No
8 T1 METER PANEL-1 as per schematic (Excluding MSEDCL METER) 1 No
9 T1 METER PANEL-2 as per schematic 1 No
10 T1 METER PANEL-3 as per schematic 1 No
11 T1 METER PANEL-4 as per schematic 1 No
12 T1 METER PANEL-5 as per schematic 1 No
13 T1 METER PANEL-6 as per schematic 1 No
14 T2 METER PANEL-1 as per schematic 1 No
15 T2 METER PANEL-2 as per schematic 1 No
16 T2 METER PANEL-3 as per schematic 1 No
17 T2 METER PANEL-4 as per schematic 1 No
18 T2 METER PANEL-5 as per schematic 1 No
19 T2 METER PANEL-6 as per schematic 1 No
20 T3 METER PANEL-1 as per schematic 1 No
21 T3 METER PANEL-2 as per schematic 1 No
22 T3 METER PANEL-3 as per schematic 1 No
23 T3 METER PANEL-4 as per schematic 1 No
24 T3 METER PANEL-5 as per schematic 1 No
25 T3 METER PANEL-6 as per schematic 1 No
26 T4 METER PANEL-1 as per schematic 1 No
27 T4 METER PANEL-2 as per schematic 1 No
28 T4 METER PANEL-3 as per schematic 1 No
29 T4 METER PANEL-4 as per schematic 1 No
30 T4 METER PANEL-5 as per schematic 1 No
31 T4 METER PANEL-6 as per schematic 1 No
32 T5 METER PANEL-1 as per schematic 1 No
33 T5 METER PANEL-2 as per schematic 1 No
34 T5 METER PANEL-3 as per schematic 1 No
35 T5 METER PANEL-4 as per schematic 1 No
36 T5 METER PANEL-5 as per schematic 1 No
37 T6 METER PANEL-1 as per schematic 1 No
38 T6 METER PANEL-2 as per schematic 1 No
39 T6 METER PANEL-3 as per schematic 1 No
40 T6 METER PANEL-4 as per schematic 1 No
41 T6 METER PANEL-5 as per schematic 1 No
42 LIG METER PANEL-1 as per schematic 1 No
43 LIG METER PANEL-2 as per schematic 1 No
44 LIG METER PANEL-3 as per schematic 1 No
45 Internal common area panel as per schematic 7 No
46 Utility panel as per schematic 5 No
47 Sump Pump Panel as per schematic 2 No
48 Fire fighting panel as per schematic 2 No
49 Fire emergency panel as per schematic 2 No
50 Fire emergency ventillation panel as per schematic 2 No
51 Emregency Panel as per schematic 6 No
52 T1 MAIN DG PANEL as per schematic 1 No
53 T1 DG PANEL1 as per schematic 1 No
54 T1 DG PANEL2 as per schematic 1 No
55 T2 MAIN DG PANEL as per schematic 1 No
56 T2 DG PANEL1 as per schematic 1 No
57 T2 DG PANEL2 as per schematic 1 No
58 T3 MAIN DG PANEL as per schematic 1 No
59 T3 DG PANEL1 as per schematic 1 No
60 T3 DG PANEL2 as per schematic 1 No
61 T4 MAIN DG PANEL as per schematic 1 No
62 T4 DG PANEL1 as per schematic 1 No
63 T4 DG PANEL2 as per schematic 1 No
64 T5 MAIN DG PANEL as per schematic 1 No
65 T5 DG PANEL1 as per schematic 1 No
66 T5 DG PANEL2 as per schematic 1 No
67 T6 MAIN DG PANEL as per schematic 1 No
68 T6 DG PANEL1 as per schematic 1 No
69 T6 DG PANEL2 as per schematic 1 No
70 LIG DG PANEL as per schematic 1 No

1.3 DG BREAKER PANEL

Design, Manufacture, Assemble, Supply, Installation Testing &


Commissioning of Sheet steel fabricated panel, made out of 2mm thick
sheet steel, duly treated by 7 tank process and powder coated,using only
approved components,50kA Aluminium Bus bars,continuous earth bars with
2nos.earth terminals,necessary lifting hooks, all necessary gland plates &
glands complete as per specifications & single line diagram. All panels with
top / bottom entry provision. Wherever the breaker and /or multidata meters
are with RS 485 ports such ports shall be hard wired and brought to a
suitable terminal block in the panel in a selected location in the panel. Only
galvanised, Zinc passivated hardware shall be used for assembling.

The Panel shall be as per the SLD

1.3.1 DG Sync/AMF Panel,suitable for 2 no's 400 KVA DG set as per schematic 1 No

1.3.2 DG Sync/AMF Panel,suitable for 2 no's 275 KVA DG set as per schematic 1 No

1.3.3 DG AMF Panel,suitable for 1 no's 125 KVA DG set as per schematic 1 No
PROJECT :PROVIDENT KENVISTA,PUNE
SUBJECT :DEFECT LIABILITY CHARGES FOR ELECTRICAL WORKS
SR.NO PARTICULARS UOM AMOUNT IN INR
1 Defect laibility Charges for First Year Ls
2 Defect laibility Charges for Second year Ls
3 Defect laibility Charges for Third Year Ls
4 Defect laibility Charges for Fourth Year Ls
5 Defect laibility Charges for Fifth Year Ls
GRAND TOTAL IN INR(EXCL.GST) -

Page 6 of 9 Electrical BOQ


SR.NO EQUIPMENT DESCRIPTION MAKES OF EQUIPMENT

1 Air Circuit Breaker Havells/ Legrand / ABB / Schneider


2 Moulded Case Circuit Breakers Havells / ABB /Schneider/Legrand
3 MCB’s, ELMCB and ELCB’s Havells/ ABB /Schneider/Legrand
4 Distribution Boards Legrand/ABB/Schneider/Havells
5 Current Transformers Indcoil / Kappa.
6 CT Test Link Elmex
7 Protection relays Alstom / C & S PC / Siemens
8 Meters MSEDCL Approved Make
9 Control switches Alstom / Kaycee / L & T
10 Control Fuses Siemens
11 Indicating Lamps, Push Buttons. Techno / Visno /Siemens /Essen.
12 Contactor Siemens / L & T /Schneider/ABB
13 Terminal block Elmex type CST / equal
14 Wires Havells / Polycab/ sALZER/Lapp
15 Auto Transfer Switch /ACCL Prok Devices/Nagoba/Salzer
16 CAT – 5 / 6 Schneider/Dlink/Legrand
17 Light Fixtures Philips,Wipro,CG,Havells
18 LT Cables Polycab, KEI, Havells
19 Copper Flexible Cables. Finolex / Polycab/KEI
20 Cable end - Terminations Comet, Dowells, Jainson
21 Cable Trays & Raceways Ramcorp/Pushpak/profab
22 Plate,switches & sockets Schneider/salzer/havells/legrand
23 Metal Clad Sockets Schneider/C & S/Legrand
24 Rotary switches Kaycee
25 Dimmers Dynalite, Legrand/Schneider
26 Load Manager/KWH Mter L&T , Legrand,Schneider
27 Inverters Luminous, Microtec ,Champion, Numeric
28 UPS Eaton/Emerson
29 M.S. / PVC/ galvanised steel Conduits Polycab/VIP/Universal/Precision
30 Light Sensor Philips, Wipro, Schneider, Legrand
31 Floor Junction Boxes Profab/ramcorp/pushpak
32 APFC Relay L & T / Schneider/ Legrand
33 Capacitors Schneider/Epcos/ L&T/ Legrand
34 Protection Relays Alstom /L & T/ABB / Legrand
35 Lightning Arrestor (spike cu rod) Any reputed make
36 Invertor/Ups Battery Exide/Ameron/Any reputed make
37 Motor Protection Circuit Breakers Siemens / Schneider/Legrand/
38 Starting Battery(SMF) Chloride/Amco/ Standard
39 Patch Panel Dlink/Legrand/Sysco
40 AMF Logic Panel-Controller Dief/Coamp/Woodword
41 Bimetal overload relays Siemens /Schneider / L&T
42 Control Transformers Siemens /ABB
43 HT Cable KEI/Polycab/Havells
Page 7 of 9 Electrical BOQ
SR.NO EQUIPMENT DESCRIPTION MAKES OF EQUIPMENT
44 RMU ABB/Schneider/Megawin/MSEDCL Approved Make

Page 8 of 9 Electrical BOQ


SR.NO EQUIPMENT DESCRIPTION MAKES OF EQUIPMENT
45 Telephone/data Socket Schneider/salzer/havells/legrand
46 Data Cables Dlink/Legrand
47 Telephone/TV Cables Dlink/Legrand
48 Tele. Tag blocks Dlink/Legrand
49 Epabx Any reputed make
50 FOR 630 KVA, 22 KV / 0.433KV OIL TYPE TRANSFORMERS Schneider/ABB/Universal transformers/MSEDCL Approved Make
51 Voltage Stabilizer Servo
52 500/275/125 KVA DG SET
i Engine Caterpillar/Kirloskar/Cummins
ii Alternator Stamford / CGL/Lerry Sommer
53 FA-PA
i FA PANEL/Detector/MCP/HOOTER/Module Notifier /Fire Autority Approved Make

ii FRLS Armoured Cable-red colour Any reputed make with 2 hrs fire rating /Fire Autority Approved Make

iii PA Cable (Speaker) Any reputed make with 2 hrs fire rating /Fire Autority Approved Make

54 CCTV Hikvision/CP PLUS/Panasonic/Nordan


55 Biometric/Access Control Zicom/Matrix
56 Audio Video Conference System LG/Sony/Samsung
57 WIFI Cisco/Dlink
58 TV Videocon/Panasonic/Onida
NOTE: All materials shall be of the best quality with `ISI’ marking. The Client/Architect/Consultants reserve the right of choice of any item

Page 9 of 9 Electrical BOQ

You might also like