siemens.com/sinamics-g120c
SINAMICS G120C | MEMBER OF THE SINAMICS FAMILY
The compact
converter series
Packed with powerful functions
Frame size FSAA Frame size FSA Frame size FSB Frame size FSC Frame size FSD Frame size FSE Frame size FSF
0.55 kW to 3 kW to 5.5 kW to 11 kW to 22 kW to 55 kW 75 kW to
2.2 kW 4 kW 7.5 kW 18.5 kW 45 kW 132 kW
2
THE TYPICAL APPLICATIONS | SINAMICS G120C
Applications at a glance
• Centrifugal pumps
• Radial/axial fans
• Compressors
Moving
• Belt conveyors
• Roller conveyors
• Chain conveyors
• Treadmills
• Bucket conveyors
Processing
• Mills • Agitators
• Mixers • Centrifuges
• Kneaders • Extruders
• Crushers • Rotary furnaces
3
SINAMICS G120C | FEATURES AND BENEFITS
Features Benefits
Compact • Frame size FSAA needs up to 30 % less space • Compact design that requires little space in the
than equivalent converters cabinet and reduces the cost for the electrical
• Frame size FSD to FSF: especially compact with cabinet
integrated DC reactor • Can be used in small control cabinets, close to
• High power density, smaller envelope dimen- the machine
sions • SINAMICS G120C devices can be mounted next
• Side-by-side mounting without derating to one another without derating. This saves
additional space.
• Long service life, high reliability
• Frame sizes FSD to FSF have an integrated DC
reactor so that an input reactor is not required
Simple • Cloning function using BOP-2, IOP or SD card • Standard applications can be easily set up with
commissioning • Optimized parameter set the IOP (Intelligent Operator Panel) using appli-
and operation • Optimized commissioning cation-specific wizards
• Integrated USB port • Intuitive series commissioning, which reduces
• Easy configuration cost and saves time
• Simple and fast software settings
• Simple handling during commissioning and in
operation
• Simplified commissioning with a common hard-
ware configuration for all components. The
converter automatically goes online, even be-
yond network boundaries (routing/remote
maintenance).
Perfect • Fully integrated into the TIA Portal system diag- • Shared data management
integration nostics • Uniform, end-to-end operating concept
• SINAMICS Startdrive – Intuitive converter • Engineering efficiency
engineering and perfect interaction with • Consistent, end-to-end control of the drives
SIMATIC in the Totally Integrated Automation • Coordinated portfolio
Portal • Integrated safety technology
• TIA Portal libary concept • Reliable system diagnostics
Leading-edge • Integrated standard safety feature STO (Safe • No external components required – including
technology Torque Off): Prevents the motor from moving PROFIsafe – thanks to certified Safe Torque Off
unexpectedly and complies with safety standard safety function (STO)
SIL 2 according to EN 61508 respectively PL d, • Fully integrated as standard in the converter
Cat 3 according to EN ISO 13849.
• Energy-efficient, encoderless vector control
- automatic flux reduction with V/F ECO
Reliable • Frame size FSAA to FSC: PROFINET • Uses all of the common bus systems
communication (PROFIEnergy / PROFISafe), PROFIBUS, • Flexible use and simple plug in
USS Modbus RTU, EtherNet/IP • Uninterruptible thanks to the optional
• Frame size FSD to FSF: PROFINET 24V power supply
(PROFIEnergy / PROFISafe / PROFIdrive), • Increased performance with PROFINET
EtherNet/IP • PROFINET profile PROFIsafe: Safety-related
communication – open, integrated and proven
• PROFINET profile PROFIenergy: Communication
with energy saving potentials
• PROFIdrive: Rapid and easy implementation
of drive concepts
4
IN THE AUTOMATION ENVIRONMENT | SINAMICS G120C
A customized
solution is simply integrated –
thanks to intelligent software
Selection
DT Configurator
• Fast product selection and ordering
• The optimum SINAMICS converter is selected to address the specific
requirements of the application
• 2D/3D models, operating, instructions,
data sheets
siemens.com/dt-configurator
Panels
• Commissioning and diagnostics directly at the drive
• Using BOP-2, IOP or SD card
5
SINAMICS G120C | IN THE AUTOMATION ENVIRONMENT
Optimally integrated
in the automation
Complete motion control solutions
The task:
Our solution:
6
IN THE AUTOMATION ENVIRONMENT | SINAMICS G120C
Teamwork for
perfect integration
SINAMICS G120C and TIA
Feature Benefit
• Drives are fully integrated into the TIA Portal system • Drive messages in plain text without requiring any
diagnostics engineering are automatically available in the TIA Portal,
control, web server and HMI
•R
outing across network boundaries • Time-saving as the device can be simply and centrally
accessed – remote maintenance
•P
arameter download via data block • Simplified series commissioning and replacement of parts
• GSD script already included in STARTER V4.5 • Simple and synchronized telegram configuration be-
tween STARTER and the TIA Portal
•U
se of the TIA Portal library concept • The library concept guarantees simple reusability of the
converter, including parameter settings and hardware
components
•T
he SIMATIC Energy Suite - an integrated option for • Energy management efficiently combined with the auto-
TIA Portal mation to increase energy transparency in production
7
SINAMICS G120C | A SYSTEM OVERVIEW
10
Fuse/
circuit breaker
6
Class B line filter
5
Line USB cable
reactor
Controller
BOP-2 IOP
IOP
1
Handheld
SINAMICS
G120C
2 3 4 7
Braking
resistor
PROFINET
8
11
Output
reactor Shield
connection plate
9
Motor
1 SINAMICS G120C (with / without Class A line filter) 7 Braking resistor converts the braking energy into
heat
2 Basic Operator Panel (BOP): user-friendly menu 8 Output reactor reduces the rate of voltage rise
navigation and two-line display. Standard commis- (dv/dt) and the current amplitude
sioning using the cloning function
3 Intelligent Operator Panel (IOP): user-friendly and 9 Standard induction motor for general applications
high-performance operator panel. Simple commis-
sioning of standard applications using application-
specific wizards
4 IOP Handheld: simple local commissioning using the 10 Fuse / circuit breaker: overcurrent protection
handheld version of the Intelligent Operator Panel
(IOP)
5 Line reactor: smoothes the current drawn by the 11 Shield connection plate makes it easier to connect the
converter and thus reduces harmonic components in shields of supply and control cables. Provides mechanical
the line current strain relief and ensures an optimum EMC level
6 Class B line filter to obtain a higher radio interference
class
8
TECHNICAL DATA | SINAMICS G120C
Technical data
Voltage/frequency 3 AC 380 – 480 V –20 % +10 % with 47/63 Hz +/–5 %
Power range 0.55 – 132 kW/ 0.75 – 150 hp
Overload power For ILO _out (LO¹): 150 % for 3 sec., plus 110 % for 57 sec.
within a 300 sec. load cycle
For IHO _out (HO²): 200 % for 3 sec., plus 150 % for 57 sec.
within a 300 sec. load cycle3
Degree of protection IP20/UL open type
Ambient temperature -10° to 40 °C without derating/up to 60 °C with derating
EMC with Class A filter Device fulfills the requirements according to
EN 61800-3 Category C3 (industrial low-voltage line supplies)
Device complies with the limit values of cable-conducted and radiated interference
voltages according to EN 61800-3 Category C2 (public low-voltage grid)
Motor cable lengths Frame size FSAA: 50 m shielded/100 m unshielded
Frame size FSA-FSC: 150 m shielded/150 m unshielded
Frame size FSD-FSE: 200 m shielded/300 m unshielded
Frame size FSF: 300 m shielded/450 m unshielded
Signal inputs/outputs 6 DI/ 2 DO/ 1 AI/ 1 AO
Safety technology SIL 2 acc. EN 61508, PL d acc. EN ISO 13849, class 3 acc. EN 60204
Control modes Vector, V/f, V/f ECO
Energy functions Energy-saving calculator, energy consumption calculator, automatic flux reduction
Function Fixed speed setpoint, PID controller, motor holding brake control, free functions blocks
Braking Integrated braking chopper
Communication FSAA to FSC available with PROFINET, PROFIBUS, EtherNet/IP, USS/Modbus RTU.
FSD to FSF available with PROFINET
Dimensions
9
SINAMICS G120C | SELECTION AND ORDERING DATA
SINAMICS G120C – converter 3-phase supply voltage 380 - 480 V SINAMICS G120C – options
Rated Rated Output Output Article number Article number Article number Article number
power power current current Frame Power Modules with
P LO1 P LO1 I LO1_out I HO2_out5 size Unfiltered Power integrated Class B line filter Line reactor 3AC
(kW) (hp) (A) (A) Modules Class A line filter 4 (footprint)7 side-mounted
10
SELECTION AND ORDERING DATA | SINAMICS G120C
Article number Article number Article number Article number Article number Article number
Shield plate
for Power
Footprint line Braking resistor Footprint braking Output reactor Footprint output Sine-wave filters
Modules
reactor side-mounted resistor side-mounted reactor
Accessories
Operator panels Article number Training Article number
BOP-2 Basic Operator Panel 6SL3255-0AA00-4CA1 Training case SINAMICS G120C PN FSA 6AG1067-2AA00-0AA0
with motor and panels
IOP Intelligent Operator 6SL3255-0AA00-4JA1 Starter kits SINAMICS G120C quick and 6SL3200-0AE31-0AA0
Panel convenient implemantation of drive tasks (without filter)
on TIA Portal
6SL3200-0AE30-0AA0
(PROFINET; 0,55 kW; frame size FSAA)
(with Class A line filter)
including control panel BOP-2
siemens.com/sinamics-starter-kits
¹ LO = Low Overload (continuous operation) ⁵ The continuous output current is not reduced when using the
overload capability
² HO = High Overload (cyclic duty)
6
Available in the 1st half of 2017
³ FSAA to FSC available with PROFINET, PROFIBUS, EtherNet/IP,
USS/Modbus RTU 7
n unfiltered power module is required for use of the external
A
FSD to FSF available with PROFINET and EtherNet/IP Class B line filter
B = RS485 with USS/Modbus RTU 8
or detailed information please refer to
F
P = SUB-D with PROFIBUS DB
siemens.com/drives-options-partner
F = PROFINET; EtherNet/IP
For detailed and further information about SINAMICS G120C
⁴ For detailed information on maintaining interference classes,
converter please refer to Catalog D31 or the Siemens Industry Mall
refer to the product documentation
web page: mall.industry.siemens.com
11
There ׳s more to it:
siemens.com/ids
Integrated
Drive Systems
to go: Visit our
mobile site!
Follow us on:
www.twitter.com/siemensindustry
www.youtube.com/siemens
Published by
Siemens AG 2016
Digital Factory
P.O. Box 31 80
91050 Erlangen, Germany
Subject to changes without prior notice
Article No. E80001-A360-P210-V7-7600
Printed in Germany
Dispo 21500
WÜ/1000173743 WS 11167.0
The information given in this document
only contains general descriptions and/or
performance features which may not always
specifically reflect those described,
or which may undergo modification in
the course of further development of
the products. The requested performance
features are binding only when they are
expressly agreed upon in the concluded Contact person
contract.
For the secure operation of Siemens
products and solutions, it is necessary
to take suitable preventive action (e.g.
cell protection concept) and integrate
each component into a holistic, stateof-
the-art industrial security concept.
Third-party products that may be in use
should also be considered.
For more information about industrial
security, visit
http://www.siemens.com/industrialsecurity