0% found this document useful (0 votes)
340 views3 pages

ACB Schneider

This document provides product data and specifications for an MVS12N4NW2A drawout electrical circuit breaker. It is an EasyPact MVS circuit breaker with 4 poles, a breaking capacity of 50kA, and an electronic trip unit rated for 1250A. Key specifications include its 50/60Hz frequency, 1250A rated current, 1000V rated insulation voltage, 12kV rated impulse withstand voltage, and 690V rated operational voltage.

Uploaded by

Sandhi Yudiyanto
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
340 views3 pages

ACB Schneider

This document provides product data and specifications for an MVS12N4NW2A drawout electrical circuit breaker. It is an EasyPact MVS circuit breaker with 4 poles, a breaking capacity of 50kA, and an electronic trip unit rated for 1250A. Key specifications include its 50/60Hz frequency, 1250A rated current, 1000V rated insulation voltage, 12kV rated impulse withstand voltage, and 690V rated operational voltage.

Uploaded by

Sandhi Yudiyanto
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Product data sheet MVS12N4NW2A

Characteristics EP MVS CB 1250A 50kA 4P EDO 240VAC ETA2


drawout electrical circuit breaker

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Main
Range of product EasyPact MVS
Range EasyPact
Product name MVS12N
Device short name MVS12N
Product or component type Circuit breaker
Device application Distribution
Poles description 4P
Protected poles description 4P 4d
Neutral position Left
Network type AC
Breaking capacity code N
Suitability for isolation Yes conforming to IEC 60947-2
Utilisation category Category B
Trip unit name ETA2I
Trip unit technology Electronic
Trip unit rating 1250 A

Complementary
Network frequency 50/60 Hz
Control type Electrically operated
Mounting mode Drawout
Mounting support Rail
Base plate
Connection position Horizontal
Vertical
Location of connection Rear
[In] rated current 1250 A at 40 °C
[Ui] rated insulation voltage 1000 V AC 50/60 Hz conforming to IEC 60947-2

Oct 23, 2019


1
[Uimp] rated impulse withstand voltage 12 kV conforming to IEC 60947-2
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
Circuit breaker CT rating 1250 A
Breaking capacity 50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity 50 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 20000 cycles (with maintenance) conforming to IEC 60947-2
10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability Category B: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Category B: 4000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Connection pitch 115 mm without spreader
Contact position indicator Yes
[Icm] rated short-circuit making 105 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
capacity
[Icw] rated short-time withstand current 50 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2
25 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Neutral protection setting Without protection (3d)
0.5 x Ir (3d + N/2)
1 x Ir (4d)
Trip unit protection functions LI
Protection type Instantaneous short-circuit protection
Overload protection (long time)
Fault indication Internal fault
Short-circuit
Overload
Long time pick-up adjustment type Ir Adjustable 9 settings
Long time pick-up adjustment range 0.4...1 x In
Long time delay adjustment type Adjustable 9 settings
[Tr] long-time delay adjustment range 0.5…24 s at 6 x Ir
Thermal memory 20 minutes before and after tripping
Instantaneous pick-up adjustment type Adjustable 9 settings
Ii
Instantaneous pick-up adjustment 1.5...10 x Ir
range
Zone selective interlocking ZSI With
Display type Digital display
Type of measurement Current
Current sensor rating range 400/2000 A
Maximum breaking time 25 ms
Maximum closing response time 70 ms
Height 439 mm
Width 556 mm
Depth 395 mm
Net weight 85 kg

Environment
Standards IEC 60947-2
Product certifications CCC
GOST
CCS
IEC
IP degree of protection IP40
Pollution degree 4 conforming to IEC 60664-1
Ambient air temperature for operation -5…70 °C
Ambient air temperature for storage -40…85 °C without control unit
-25…85 °C with control unit

2
Contractual warranty
Warranty 18 months