Chapter 3 Exercises

1. Determine the maximum factored load that the beam can carry based on the positive moment capacity
of the beam. The beam has a width of 250mm, effective depth of 437.5mm, fc' = 25MPa and 3-25mmf,
Grade 40 rebars.

6.5m 0.7m C
A B
2. The beam below has top bars at Point A of 4-25mmf bars and 3-25mmf rebars near the midspan of Span
AB. The beam dimensions are b = 250mm and d = 430mm. Determine the live load that the beam can
carry based on the moment capacities. The dead load is 22.6 kN/m. Use fc' = 25 MPa and 3-25mmf,
Grade 40 rebars.

A 7.4m 1.0m C
B

3. The beam shown has factored loads of Pu = 260 kN and wu = 20.2 kN/m. Determine the required size of
the prismatic beam using a d/b ratio of 2.0 and a steel ratio of 1.2%. Round off b and h to the nearest
50mm. Use fc' = 30 MPa and Grade 60 rebars, concrete cover of 40mm, 12mmf stirrups and main bars of
32mmf in a single layer. Determine the required number of main bars.

P P

4.2m 1.7m 3.7m


A B

4. The beam shown has factored loads of Pu = 190 kN and wu = 35 kN/m. Using a steel ratio of 2.5 times
the minimum and a d/b ratio of 1.8, determine the the size b and h of the beam. Determine also the
required number of 25mmf rebars. Use 10mmf stirrups, 50mm concrete cover, fc' = 35 MPa and Grade
60 bars.
P 1.8P

4.2m 3.9m 3.5m 3.7m


A C
B
5. Determine the maximum live load that the beam can carry if the dead load is 16.4 kN/m and based on
the capacity of the beam section at B as shown. Use fc' = 40 MPa and Grade 60 bars.

70mm
7 - 36mm
108mm
w

352mm
7.2m 6.7
m 4-
A B C 36mm
70mm
300mm
6. Design the reinforcements of the doubly reinforced beam for the maximum positive moment. Use b =
250mm, d = 170mm and d' = 70mm; fc' = 25 MPa and 32mmf Grade 40 rebars.

92 kN/m

38 kN/m

8.7m 0.7m

A B
7. Determine the live load that the beam below can carry based on the negative moment capacity of the
section shown. The dead load is 14.2 kN/m excluding beam weight. Use fc' = 30 MPa and Grade 40
rebars.

120 60
w

A 7.3m
0.7m 1.6m 5.4m 520
C E
B D
100

80 290 80

8. Determine the maximum floor load that the simply supported interior stringer can carry based on the
capacity of the section shown. Use fc' = 30 MPa and Grade 40 rebars. The slab thickness is 100mm,
stringers are spaced 3.1m on centers, has a span length of 7.5m. a web width of 300mm, effective
depth of 480mm and the interior stringers have 6-25mmrebars.

Wall Load

Floor Load
9. Determine the required number of 25mmf of the exterior beam in Problem (8) if the factored
superimposed floor load is 15.4 kPa and wall load is 12.4 kN/m.
10. Determine the required number of 20mmf of the channel floor joist shown. The top flange is 500mm
wide and 70mm thick. The overall height of the joist is 360mm, web widths are 80mmand the effective
depth is 320mm. It is designed to carry a factored floor load of 125 kPa. The simple span length is 9.1m.
Use fc' = 50 MPa and Grade 60 rebars.