You are on page 1/ 23

Access Network

Information Service Portal

Fixed Network Information Dept http://support.huawei.com/enterprise

Copyright © Huawei Technologies Co.,Ltd. 2016. ALL rights reserved.


CONTENTS
3 Solution

1
POL
18 / Panorama of the AgilePOL Solution
20 / AgilePOL Enterprise Solution
24 / AgilePOL Hotel Solution
28 / AgilePOL Campus Solution

Concept of POL
POL 04
05
06
/
/
/
From PON to POL
Architecture of the POL
ODN Deployment

4
07 / Comparison Between the POL and Traditional LAN

Technical Innovation and


Market Performance
GPON

2
34

Key Technologies
10
11
13
14
/
/
/
/
High Bandwidth
High Reliability
Comprehensive Security Authentication
Easy Deployment
5 POL Product
38

15 / Video Surveillance and Wi-Fi Coverage

Acronyms
and
Abbreviations
42
POL
1
Concept of POL
From PON to POL
Architecture of the POL
ODN Deployment
Comparison Between the POL and Traditional LAN

AGILEPOL 02 AGILEPOL 03
POL and PON
From PON to POL The passive optical LAN (POL) can be viewed as a PON for enterprise applications. Its networking mode and

components of the active and passive parts are similar to those of an FTTH network. Regarding the network scale

and types of access users, optimization is made on the POL to meet enterprise customers' requirements. Using

What Is PON? the POL technology, an enterprise can combine data, voice, video, and wireless access systems into one optical

network. Therefore, POL has advantages over other technologies.


A passive optical network (PON) is a point-to-multipoint (P2MP) network.

Gigabit passive optical network (GPON) is one of the PON technologies, and is defined by the ITU-T G.984.x
Higher
series of Recommendations.
bandwidth
(GPON) Longer
1.25 Gbit/s (upstream)
transmission reach
Lower
SNI S/R ODN R/S UNI 2.5 Gbit/s (downstream) More flexible
CAPEX and OPEX >20km
design
(passive and
more deployment
simplified network)
space

ONU

Architecture of POL
IFgpon IFgpon
Service Node CPE

Optical splitter
OLT

ONU The POL is an enterprise LAN based on the PON technology. It provides users with integrated data, voice, video,

Passive part and low current services through optical fibers.


Active part (optical fiber + optical splitter) Active part

Data/ Backbone
LAN Softswitch
◆ IFgpon: GPON Interface ◆ UNI: User to Network Interface ◆ SNI: Service Node Interface ◆ CPE: Customer Premises Equipment Operation center WAN Router
Service storage

OLT
◆ The OLT has both Layer 2 and Layer 3 functions. It provides interfaces between the core switching
layer and the PON, encodes Ethernet data and transmits the encoded data over the PON, and
manages upstream data streams from the ONU.
Telecom riser Up to 20 km ODN

◆ Through the twisted pair or in a wireless manner, the ONU transmits signals to multiple types of
Building Single-fiber, single-mode
IP-based devices, such as computers, IP phones, and cameras.

◆ On a passive ODN, the optical splitter broadcasts downstream signals from the OLT to multiple Wireless AP PC
ONUs. The ONU transmits data upstream through dynamic Time Division Multiple Access (TDMA).
Security TC
The optical splitter combines the data and transmits the combined data to the OLT. User surveillance device POTS phone
ONU ONT
BRAS TV

AGILEPOL 04 AGILEPOL 05
ODN Deployment Comparison Between
the POL and Traditional LAN
The ODN is an FTTx network based on PON devices, which provides the optical transmission path between the

OLT and the ONU. The ODN can be deployed in campuses and buildings.
Network Structure Comparison

ODN deployment in the campus


Traditional LAN POL
OLT Optical distribution point AP ONU
Core switch Core switching layer
Feeder optical Distribution Horizontal optical cable
cable optical cable in the building

Convergence
Telecom riser switch
Indoor Convergence
in the building layer
OLT

Central Centralized outdoor


equipment roomt fuber distribution Access Optical
(optional) switch splitter
Access
Equipment room layer
in the building ONU
Manhole

Closure Underground

Data Voice WiFi Fax TV Surveillance


device

◆ On the POL, the convergence switch used on the traditional LAN is replaced with the OLT, copper lines are
Feeder optical cable FDT Distribution FAT (with the built Drop cable
optical cable in optical splitter) replaced with optical fibers, and the access switch is replaced with the passive optical splitter.

◆ The ONU supports Layer 2 functions. It provides users with data, voice, and video services in a wired or

ODN deployment in the building wireless manner.

PASSIVE
Horizontal optical cable

Horizontal
optical cable OPTICAL
LAN
Drop cable
FAT
(with the built in optical splitter)

ODF Central equipment room

AGILEPOL 06 AGILEPOL 07
2
Key Technologies
High Bandwidth
High Reliability
Comprehensive Security Authentication
Easy Deployment
Video Surveillance and Wi-Fi Coverage

AGILEPOL 08 AGILEPOL 09
High Bandwidth High Reliability E2E

As users' demands on 4K video, VR, and desktop cloud grow, NG PON is gradually put into commercial use. There The POL uses E2E high-reliability design. For example, the OLT supports ISSUs of control and service boards at
are a complete set of optical access standards, including GPON (2.5G), NG PON (10G), and the coming WDM the core NE for service access. During ISSUs, control and service boards are reset, but the forwarding plane
PON. The standards focus on smooth evolution, fully use existing resources, and support network upgrades with remains operating, ensuring no service interruption and enhancing the system reliability.
minimum investment and fewest modifications. Made of non-metal materials, the optical fiber does not corrode
easily and can be used for more than 30 years. It provides a maximum bandwidth of 1 Tbit/s. Therefore, the
Internet WAN
existing network does not need to be reconstructed, and only device upgrades are required to meet the future
explosive bandwidth demands.
Campus Reliability of the egress layer
egress
Huawei Solution Egress ◆ Fast route convergence
router ◆ ECMP
Huawei AgilePOL solution provides GPON and 10G GPON solutions to meet enterprise customers' requirement of
1 Gbit/s desktop access. GPON, 10G PON, and the coming 40G PON share ODN networks and optical fibers for
Firewall
smooth upgrades and investment reduction.
Reliability of the core layer
NMS reuse OLT reuse ODN reuse ONU/ONT reuse Core ◆ Cluster
layer ◆ Routing
EMS GPON ◆ VRRP
Core
switch

ODN ONU
Convergence
Reliability of the convergence
10G PON layer and access layers
OLT ◆ Dual OLTs support type B dual-homing.
◆ Type B single-homing can be configured for
IP ONU scenarios not requiring redundancy.
network
WDM PON
Optical
splitter Reliability of the OLT
OLT Control board redundancy
GPON/ When the active control board is faulty, the standby
10G GPON control board ensures no service interruption and
supports in-service software upgrades (ISSUs).
Optical splitter
Power board redundancy
When the active power board is faulty, the standby
Compared with GPON, 10G GPON implements overall capacity expansion at the physical layer, and provides a
power board ensures normal running of the OLT.
maximum downstream rate of 9.95 Gbit/s, a maximum upstream rate of 9.95 Gbit/s, and a maximum split ratio of Access
ONU
1:256. In addition, more ONUs can be connected to the same PON port, which is suitable for high-density Enterprise Upstream board redundancy
campus Two upstream boards are configured on the OLT, with
scenarios. layer AP each board providing an upstream port. The two
upstream ports are configured as a Link Aggregation
10G GPON uses the original mechanism at the transmission convergence layer and optimizes the frame structure
Control Protocol (LACP) pair, which implements port
to adapt to the 10 Gbit/s rate. In addition, 10G GPON enhances the flexibility of dynamic bandwidth assignment fault detection, protection switchover, and service
recovery.
(DBA), simplifies the message management mechanism at the physical layer, and improves the security and
energy-saving performance.

AGILEPOL 10 AGILEPOL 11
High Reliability Type B Dual-Homing Comprehensive
Security Authentication
How does the POL ensure the reliability of enterprise customers' services?
How does the POL authenticate the various types of devices that access the network from different places and
through different modes?
Huawei Solution
Recommendation G.984.1 defines 4 types of dual-PON protection configurations, among which type B protection Huawei Solution
networking and type C protection networking are practicable. Compared with type C protection, type B protection is Huawei AgilePOL solution provides comprehensive security authentication and access control to authenticate
cost-effective and provides redundancy protection for both OLT PON ports and backbone fibers. When the OLT, different devices that access the network in different scenarios, ensuring that only the devices of authorized users
OLT PON port, or backbone fiber is faulty, services can be automatically switched to the redundant one. can access the network.

◆ The ONU supports MAC address binding, prohibiting the use of unauthorized terminals (for example, cameras).
Type B dual-homing Type B single-homing ◆ The MPLS VPN connects the HQ and branches. The SSL VPN connects to the Internet for the access of employees on business visits and
The ONU is connected to 2 OLTs that are in active/standby state. The 2 upstream ports of an optical splitter are respectively visitors.
When the active line is interrupted due to an optical fiber, PON connected to the 2 PON boards of the same OLT. The two PON ◆ 802.1x authentication is supported. The 802.1x protocol is a physical or logical port-based network access control protocol. An 802.1x
port, or active OLT fault, the active OLT can quickly switch ports are in the active/standby state. When the active line is authentication system uses the Extensible Authentication Protocol (EAP) to exchange authentication information between the client, device,
services to the standby OLT. Type B dual-homing can be further interrupted due to an optical fiber or PON port fault, the ONU and authentication server. The EAP packets from wireless access devices can be encapsulated using Control and Provisioning of Wireless
broken down into two scenarios: OLT dual-homing and OLT quickly switches services to the backup line. Access Points (CAPWAP) for transmission.
single-homing.

OLT dual-homing OLT single-homing OLT dual-homing OLT single-homing


Extranet Internet WAN

Business visit Enterprise branch

SSL VPN authentication point MPLS VPN authentication point


Authentication
Egress router
center
Central
Equipment
Firewall
Room

802.1x authentication point

RADIUS server
AC

OLT dual-homing OLT dual-homing


When an upstream link is interrupted, type B switchover does not ◆ OLT dual-homing + VRRP at Layer 3
need to be performed at the OLT level. The OLT and Layer 3 ◆ OLT dual-homing (LACP) + eTrunk at Layer 3
switch can be connected through link aggregation group (LAG) or
Radius EAP over CAPWAP
Multiple Spanning Tree Protocol (MSTP) networking.
FDT
OLT single-homing OLT single-homing Optical splitter
When an upstream link is interrupted, type B switchover needs to LAG protection improves the system reliability.
be performed at the OLT level. The OLT and Layer 3 switch can
be connected through dual links without aggregation, or n-type or
Office Office Office
EAP
U-type networking. 802.1x authentication point

AGILEPOL 12 AGILEPOL 13
Easy Deployment Video Surveillance
and Wi-Fi Coverage
Device PnP
ONUs support plug and play (PnP). ONUs can be pre-configured on the network management system (NMS) The flexible POL networking applies to video surveillance in various scenarios.
based on the deployment plan. Specifically, after being installed and powered on, ONUs can be automatically
discovered, added, configured, and remotely software-commissioned. In this way, the deployment efficiency is high Video management

and the network construction cost is minimized. Star-and tree-type networking IP Network system

LLDP-MED device PnP IEEE 802.1ab defines a Layer 2 discovery protocol, Link Layer Discovery Protocol (LLDP) High-density access

to enable devices from different vendors to discover each other and exchange the system and configuration The uneven cascading structure
FE
optical splitter N
information. The LLDP can encapsulate the information about the local device, such as the management address, meets the outdoor chain
device information, and interface ID, into LLDP packets and transmit the packets to neighbor nodes. The neighbor
OLT networking requiremeny.
FE
nodes save the information for NMS query and link status determination. Huawei AgilePOL solution provides ONUs
optical 10:90 uneven optical splitter
that support the PnP of LLDP-MED devices. The ONUs can discover non-Huawei devices, such as IP phones, to splitter 2
High-density
ONU deploymeny
support fast service provisioning. 1:Moptical splitter 1:Noptical splitter
FE
The IP phone is connected to the ONU through
d
nta gge the RJ45 port and sends an LLDP packet to the

dat a- u ONU. FE
data- untagged optical
splitter 1

voice - tagged After receiving the LLDP packet, the ONU


dat
a- u analyzes the device type. After identifying that
nta
gge the device is a phone, the ONU sends an LLDP
d
packet to the IP phone. In this way, the ONU
automatically discovers an LLDP-MED device.

Flexible Deployment of Desktop ONU


POL provides two Wi-Fi access modes: ONU/ONT and ONU+AP
The desktop ONU provided by Huawei supports multiple deployment modes and thereby is applicable in different
User coverage Wi-Fi coverage (ONU/ONT)
office desktops.

1 ONU for each desktop 4 desktops sharing 1 ONU ONT


ONT
OSS AAA NMS

ONT
SOHO Cafe Dormitory

Public coverage Wide Wi-Fi coverage (ONU+AP)


Access Optical
2 desktops sharing 1 ONU control point splitter
OLT AP
AP

AP
ONU AP
AP

Hotel Shopping mall Campus

AGILEPOL 14 AGILEPOL 15
3
Solution POL
Panorama of the AgilePOL Solution
AgilePOL Enterprise Solution
AgilePOL Hotel Solution
AgilePOL Campus Solution

AGILEPOL 16 AGILEPOL 17
Panorama of the AgilePOL Solution POL

Application
Enterprise Enterprise Video Positioning and
communication officing Manufacturing/IoT surveillance Big data analysis navigation

Service Center Cloud Platform Unified NMS

Platform User management AAA

Sight
Terminal position Network quality
Policy control Gateway plug-in
Network O&M Capability encapsulation Network topology Alarming

Enterprise branch
Router
Campus egress WAN/Internet
Firewall

Enterprise Core switch


campus

OLT

POL
Optical splitter

ONU ONU ONU

AGILEPOL 18 AGILEPOL 19
AgilePOL Enterprise Solution POL

Challenges Huawei Solution


Large enterprises face the following challenges during network construction: Huawei AgilePOL solution, on the basis of conventional campus network, combines new changes of cloud services

◆ Many switches occupy equipment room space, consume much power, and are hard to dissipate heat. and smart terminals and uses xPON for the access of campus LANs. This solution helps enterprises build new

◆ Convergence routers have complex connections, occupy channel space, and cause difficulties in cabling and flattened networks which are easy to deploy and support service integration.

maintenance. ◆ Replacing conventional network cables with fibers can reduce investment and simplify deployment. Moreover,

◆ Switches are scattered and hard to manage, requiring huge maintenance workload. fibers are oxidation-resistant, durable, and easy to maintain.

New devices are hard to operate and expand. ◆ Passive convergence optical splitters can reduce the number of convergence switches and save the space in

equipment rooms, and save power.

Passive
Operation center ODN General office

Sight WLAN

Surveillance
ONU ONT
Terminal located
on the corridor Office

Independent office ● "One desktop, one line" providesGigabit bandwidth access and

Voice Internet easy expansion in the future.


● IP phones are connected and then PCs are connected, forming
access a simple network.

Video Desktop terminal Office


surveillance Teleconference

● The power over Ethernet (PoE) mode is used to power Wi-Fi


Open office devices and cameras.
● Office services (including phone service) are carried uniformly.

OLT PoE
ONU
AC WLAN
ONU

Office Campus IoT

AGILEPOL 20 AGILEPOL 21
Huawei Solution
Huawei uses the AgilePOL solution to build a campus LAN in its
Traditional
Xi'an R&D institute. For employee desktop cloud and voice
LAN
POL services, it applies the fiber-to-desktop network mode. For video

surveillance and Wi-Fi signal coverage, it applies the fiber-to-ceiling

network mode. In addition, the ONU uses the PoE mode to power
TCO
cameras and APs, addressing power difficulties.

XI’AN
RESEARCH
CENTER
Case of Huawei Xi'an R&D
Institute
Challenges 8 buildings and 2 dining halls;
Huawei Xi'an R&D institute is located in Xi'an high-tech industrial development zone. In an area of 330,000 square 15,000 employees;
meters, this institute includes 8 office building, 2 dining halls, and data centers, allowing 15,000 employees to work 595,000 square meters office area.
through cloud desktops. The campus network meets the access requirements of multiple services such as video

surveillance, door control, broadband, voice, and video conference.

Prevailing cloud service and big broadband service face challenges in user experience. For example, frame freezes

often occur when videos are played on the cloud desktop.

Conventional Ethernet LANs feature multiple network layers, long deployment period, complex management, and

difficult configuration.

Buildings are so large that network cable distance reaches the limit, so fibers are demanded for long-term

evolution.
80% 80% 60% 50%
Engineering costs account for a high proportion of total network construction costs. Huawei faces the problem of Line space Equipment room quantity Power consumption Engineering efficiency

how to minimize project deployment costs and build a green and energy-saving campus.
AGILEPOL 22 AGILEPOL 23
AgilePOL Hotel Solution POL

Challenges Huawei Solution


In addition to conventional single services (such as telephone and TV services), hotel networks gradually begin to Based on the requirements of services such as wireless, wired, video, voice, and guest room surveillance, Huawei
carry full services (such as surveillance, Wi-Fi, customer control, and environment perception). The full services are raises the concepts of "smart hotel" and "one room, one line, and N services" in its AgilePOL hotel solution. This
diverse, intelligent, and mobile. solution satisfies the bearing demands of hotel information systems, and simplifies the networking and

◆ Higher bandwidths: Access terminals are changing from ◆ Abundant value-added services: Services such as VoD and management.
conventional PCs to smart mobile devices such as smart control over guest rooms need to be supported.
◆ "One room, one line": Networks are simplified and costs are ◆ Multi-scenario and multi-service coverage: Users can enjoy
smartphones, demanding for high bandwidths.
◆ Economical operation: A large number of guest rooms are reduced. full services (such as the HSI, voice, TV, Wi-Fi, and customer
◆ Accessing Internet anywhere anytime: Seamless distributed in a wide area, requiring a simple and control) in places including guest rooms, halls, corridors, and
connections in places such as guest rooms, corridors, halls, easy-to-maintain network. restaurants in the hotel.
and meeting rooms are required.

Surveillance center Low current well Corridor Guest room


ONT

Optical
splitter


GE+PoE

FE+PoE
Central equipment room ONU

PSTN Internet
Cooperation Optical
splitter
Wireless AC IP PBX USG AAA PMS

ONU

ONU

Core switch

Optical
splitter
OLT ONU
AGILEPOL 24 AGILEPOL 25
Huawei Solution
The GPON solution achieves remote access of villa groups and integrated LAN and WLAN coverage inside villas.

Ubiquitous network PON+LAN is used in office areas while PON+WLAN is used in public development areas. In addition, the GPON

Ubiquitous wireless network solution enables various services (such as hotel video surveillance, bulletin service, and POS card swiping

services) to be carried over one network.

Each guest room is deployed with one ONT. These ONTs offer CATV services through RF ports, Internet access
Fiber to the villa Intelligent room services through FE ports, telephone services through POTS ports. In this way, one ONT can realize uniform
Fiber to the villa for extremely control access for voice, broadband, and video services without deploying multi-system. All-IP bearing through one fiber
high bandwidths
Smart terminal controlling all can help to simplify network structures and reduce maintenance costs.
types of service terminals

Central equipment room


NMS
Core switch

Hotel server

Case of Yunfeng Mountain Surveillance center

Villa Hotel MA5600T

Challenges
The Yunfeng mountain hot spring resort, one of China's A-level tourist attractions, is located in Tengchong county,

Yunnan province. Yunfeng mountain hotel lies in this resort and covers 640,000 square meters, being the biggest Outdoor FDT 2:32 optical splitter

villa-only hotel in Asia.

In the hotel, there are dispersedly distributed guest rooms and multiple APs. Moreover, services such as telephone,
Villa area Kadoya,
high-speed broadband, and video conference are demanded, leading to difficult network deployment. Conventional shopping place,
networks with switches are costly due to long distance deployment. In addition, the hotel involves various outdoor clubs
scenarios (such as the hot spring area, parking area, and entertainment area). However, in these scenarios, it is

hard to power devices.


Customer Bulletin Analog POS card
Telephone TV Wireless Surveillance
control service telephone swiping

Hotel guest room access Lobby and corridor access

AGILEPOL 26 AGILEPOL 27
AgilePOL Campus Solution POL

Challenges Huawei Solution


With the fast development of mobile, cloud computing, and multimedia technologies, schools need new flexible, A campus includes the dormitory area, administration area, education area, and public activity area. Huawei
open, compatible, and easy to maintain networks to achieve smart, widespread, and sharable network evolution. solution, with wide fiber coverage, supports multi-scenario services carried over one network, achieves seamless
◆ Diversified teaching methods: High broadband services such as cloud classroom and remote video education Internet access in the campus, and allows flexible expansion (PON/10 GPON/40GPON).
require that the network should support large access capacity and sustainable evolution. ◆ Gateway ONTs can realize three network integration, thereby reducing network deployment workload.
◆ Accessing network anytime and anywhere: Users can access the campus network from classroom, library, ◆ ONUs with multiple ports and PoE can meet the access requirements of various terminals in administration and
dormitory, and home anytime. education areas.
◆ Easy deployment and maintenance: Different scenarios have different requirements. For example, some ◆ Passive optical splitters can be deployed flexibly in any environments, supporting network coverage in
scenarios need simple cabling and require no weak current well. long-distance teaching buildings and labs.

Internet
VoD IP/PBX AC NMS
CERNET
Receiver
Smart
service
HDTV HSIA Telephone Wireless NMS Library Distance education Mobile study Virtual experiment

Coder/decoder 10GE Core Switch

Optical
transmission
GPON
CATV 1550 nm
IP data 1310/1490 nm OLT OLT
WDM multiplexer
Data/operation center

1:8 2:4 2:8


optical splitter optical splitter optical splitter Telecom riser information
collection box

ONT AP ONU ONU

Video
surveillance
CATV PC Phone PC Video conference IP phone AP PC Video surveillance AP

Dormitory and apartment Office Classroom Development area


AGILEPOL 28 AGILEPOL 29
Huawei Solution
Southwest University, with dispersed classrooms and high bandwidth demands in the teaching area, uses Huawei's
AgilePOL solution. In this solution, the access and aggregation integrated OLT (MA5603T) is deployed in the core
equipment room. The passive ODN achieves the fiber coverage from the equipment room to classrooms, and
offers abundant interfaces for cloud classes in multimedia classrooms. In addition, the AgilePOL network can carry
high-speed Internet access, IPTV, VoIP, and weak current services, which have promising application prospects in
the campus.

Central equipment room Weak Dormitory


Telephone
current
well
Broadband

OSS AAA U2000


Dormitory
IPTV
1:32
Internet optical ONT Broadband

Network Construction Selection


splitter

of Southwest University CERNET MA5603T


FDT Classroom

S12700 Cloud class

Challenges MA5671

Southwest University, which is listed in China's "211 Project" and "985 Classroom
Project Innovation Platform" and directly under the Ministry of Education, is a
1:16 Cloud class
key comprehensive university established by the Ministry of Education, Ministry of
Optical
Agriculture, and Chongqing government. splitter MA5671

In this university, the network in teacher apartment area is built by carriers and the
FTTH solution is used. However, in the teaching area, classrooms are dispersed
Dormitory and apartment network: Teaching network:
and far from equipment rooms. If the traditional switch solution is used, multiple
aggregation devices need to be deployed, bringing many fault risks. Moreover, the ◆ Each apartment is deployed with an ONT. ◆ Each classroom is deployed with an
◆ Telephone, broadband, and IPTV services MA5671.
network coverage is very limited. Considering these factors, the customer chooses
are carried over one network. ◆ Cloud class services are carried.
the POL solution for building the network in the teaching area.

AGILEPOL 30 AGILEPOL 31
GPON

4
Technical Innovation and
Market Performance

AGILEPOL 32 AGILEPOL 33
Standard Developer
Fully engaged in developing PON standards

Frank Effenberger Luo Yuanqiu Dekun Liu Liu Wei

GPON XG-PON1 Maintain NG-PON2 G.Multi XGS-PON

Technical Leader
◆ By Dec. 31, 2015, Huawei had applied for 4843 access network patents, among which 1102 patents obtained

approval from the World Intellectual Property Organization (WIPO) based on Patent Cooperation Treaty (PCT).

◆ In 2009 Q1, Huawei released the industry's first 10G PON prototype.

◆ In 2011 Q3, Huawei released the industry's first 40G PON prototype.

◆ In 2016 Q1, Huawei released the industry's first 100G PON prototype.

Access Network World Intellectual Property


Patents Organization (WIPO) Patents

4843 1102

Technical Innovation and Market Leader

Market Performance
According to the latest 2015 Q4 market share report released by OVUM:

Huawei's PON market share Huawei's broadband access market share

As the world-leading FTTx solution provider, Huawei has

the largest access product and solution R&D team with 34% 41%
over 15 years' project delivery experience. Huawei access

1 st
1 st
products and solutions are applied to enterprises and

telecom carriers, and have ranked first in the global market

for 10 years.

2015 Source: OVUM


AGILEPOL 34 AGILEPOL 35
POL Product
OLT
Campus ONU
ONT
ODN

5
AGILEPOL 36 AGILEPOL 37
OLT Unified access platform Core xPON NE Campus ONU Office network, video surveillance, access of Wi-Fi APs,
industrial-grade adaptability

Industry's first vOLT, 200 Gbit/s per slot, distributed forwarding Desktop-mounted

MA5800-X17 MA5800-X7 MA5671 MA5672 MA5871

Switching 10G GPON/10G EPON/GPON/


capacity of Network-side port GPON GPON/EPON GPON
7 Tbit/s EPON/GE(光)/GE(电)*
the control
board
User-side port 1GE/4GE 4GE 2GE + 8POTS 4×GE
(plastic shell,distributable) (metallic shell, distributable)
Access 17 service slots 7 service slots
capacity 4GE
136 x 10G GPON 56 x 10G GPON (plastic shell, PoE)

272 x GPON 112 x GPON

816 x GE 336 x GE Operating temperature: Operating temperature:


0℃ to 40℃ -25℃ to +55℃

Integrated fiber-copper access platform Rack-mounted

MA5821

MA5600T (ETSI) MA5600T (IEC) MA5603T MA5608T MA5620 MA5626 MA5822

Switching
capacity of
1,920 Gbit/s 256 Gbit/s Network-side port GPON 10G GPON/GPON
the control
board

Access 16 service slots 14 service slots 6 service slots 2 service slots User-side port 24FE + 24POTS 8/16/24FE MA5821
capacity 8/16/24FE
128 x 10G GPON 112 x 10G GPON 48 x 10G GPON 16 x 10G GPON 16FE + 16POTS 8/16/24FE with POE
24GE
256 x GPON 224 x GPON 96 x GPON 32 x GPON 8FE + 8POTS 4GE + 4FE with POE
MA5822
768 x GE 672 x GE 288 x GE 96 x GE
8/16/24FE + POTS
24GE + POTS

AGILEPOL 38 AGILEPOL 39
ONT Residences, hotels, and commercial buildings ODN Between OLT and ONU
For Passive Aggregation and Transmission

Bridge Indoor

ODF FAT Splitter


HG8010H HG8040H
Optical distribution frame Fiber access terminal Installed in ODF, closure, FAT, and FDT
Distributing cables from the OLT Connecting distribution cables and drop cables
Network-side port GPON
ODF3101 960 cores FAT3201-12/24/36/48 cores SPL9102, SPL9105
User-side port 1GE 4GE
FAT3106SI--8/16/32 cores SPL2605, SPL1201
1:2 -- 1:64/2:4 -- 2:64

Bridge + VoIP

ATB Drop cable FMC


HG8110H HG8242H HG8240H Used in residences and hotels Indoor/Outdoor cabling Field-mountable optical connector

Network-side port GPON ATB3101, 1–4 cores GJXFH-1B6a2 FMC2101


ATB3102, 1–2 cores GJXFH-1B6a2 FMC2102
User-side port 1POTS + 1GE 2POTS + 4GE +CATV 2POTS + 4GE ATB3201, 1–2 cores GJYXFCH-1B6a2

Gateway
Outdoor

HG8245Q Closure FDT FAT Duct/Riser cable


HN8245Q HG8247H HG8245H
Deployed in hand/man holes and Used for outdoor streetside cable Deployed in ducts and weak-current
Mounted on outdoor poles and walls
Network-side port 10G PON GPON mounted to aerial cables and poles (distribution) wells/corridors Respectively

User-side port 2POTS + 4GE + 2USB + 2.4G&5G WiFi 2POTS + 4GE + 2USB + 2.4G&5G WiFi 2POTS + 4GE + 1CATV + WiFi + 1USB 2POTS + 4GE + USB + WiFi
SSC210x series, 48/96/144/192/288 cores FDT3105D-144/288/576 series FAT2802SD 16 cores GYTA, 72/144 cores
2.4GHz: 3×3 MIMO 802.11b/g/n 2.4GHz: 3×3 MIMO 802.11b/g/n 2×2 MIMO 802.11b/g/n 2×2 MIMO 802.11b/g/n FAT3203D-6/12/18 cores GYFY, 72/144 cores
5GHz: 3×3 MIMO 802.11a/n/ac 5GHz: 3×3 MIMO 802.11a/n/ac

AGILEPOL 40 AGILEPOL 41
Acronyms and Abbreviations
AAA authentication, authorization and accounting
AC access control
AP access point
BNG broadband network gateway
CAPWAP control and provisioning of wireless access points
DBA dynamic bandwidth assignment
EAP extensible authentication protocol
ECMP equal and weighted cost multi-path
EOTDR embedded optical time domain reflectometer
GPON gigabit-capable passive optical network
HSI high-speed internet
IoT internet of things
ISSU in-service software upgrade
LACP link aggregation control protocol
LAG link aggregation group
LAN local area network
LLDP link layer discovery protocol
MSTP multiple spanning tree protocol
NGPON next generation PON
OLT optical line terminal
ODN optical distribution network
ONT optical network terminal
ONU optical network unit
OSS operations support system
OTDR optical time domain reflectometer
PBX private branch exchange
PoE power over ethernet
POL passive optical LAN
PON passive optical network
SNMP simple network management protocol
SSL secure sockets layer
USG unified security gateway
VoD video on demand
VoIP voice over internet protocol
VPN virtual private network
VRRP virtual router redundancy protocol
WAN wide area network
WDM wavelength division multiplexing
WLAN wireless local area network

AGILEPOL 42