IPASOLINK VR10 Specifications
IPASOLINK VR10 Specifications
November 2017
iPASOLINK VR 10
SPECIFICATIONS
NEC Corporation
7-1, Shiba 5-Chome, Minato-Ku, Tokyo 108-8001, Japan
GGS-000376-08E
Printed in Japan
iPASOLINK VR 10
SPECIFICATIONS
CONTENTS
1. INTERFACES 1-1
2. SPECIFICATION 2-1
1. INTERFACES
Universal Slot #11 Universal Slot #12 Universal Slot #13 Universal Slot #14 FAN2
TERM PS 1 PS Slot #2
➀ ➁ ➂ ➃ ➄
➁ CALL Push Button Press the button to call the opposing site by OW.
➃ MEM USB Type-A Connecting terminal for USB memory device. (Supporting
a memory device only.)
➄ LCT RJ-45 Connector Ethernet port for connecting WebLCT. (Supporting 10/
100BASE-TX; Auto-Negotiation, Auto-MDI/MDIX.)
1.2.1.2 TERM-MV
Required one TERM-MV Card per IDU,
➀ ➁ ➂
CLK
➂ CLK High Density D-Sub Terminal for Clock Signal input/output. (15 pins)
Connector
➀ PWR / SELV D3100 S Connector Terminal for –48 V DC power supply. Use the Safety Extra
Low Voltage (SELV). One or two PS-MV Cards can be
mounted.
1.2.1.4 FAN-MV
Required two FAN MV Cards per IDU.
1.2.2.1 MODEM-A/EA
➀ ➁ ➂ ➃
➃ MD/ODU PWR Toggle Switch Switch to supply power to MODEM and ODU.
1.2.2.2 MODEM-AV
➀ ➁ ➂
➂ MD/ODU PWR Toggle Switch Switch to supply power to MODEM and ODU.
1.2.2.3 MODEM-EV
➀ ➁ ➂
➂ MD/ODU PWR Toggle Switch Switch to supply power to MODEM and ODU.
1.2.2.4 MSE-A
Available Slots: Up to One MSE-A Card per IDU in Any Universal Slots
(#1 to #14)
1.2.2.5 AUX-A
Available Slots: Up to One AUX-A Card per IDU in Any Universal Slots
(#1 to #14)
➀
ALM/EOW/NE2 High-Density D-Sub Terminal for Housekeeping and Cluster alarms. Four input
44 Connector channels, six output channels. (44 pins)
➀ NOTE: The uses of EOW and NE1 interfaces are currently
not available.
1.2.2.7 16E1-A
1.2.2.8 GbE4e-AV
➀ ➁ ➂ ➃
1.2.2.9 GbE4f-AV
➀ OUT IN 1 SFP Module Port Traffic Terminal Port for GbE Interface 1.
➁ OUT IN 2 SFP Module Port Traffic Terminal Port for GbE Interface 2.
➂ OUT IN 3 SFP Module Port Traffic Terminal Port for GbE Interface 3.
➃ OUT IN 4 SFP Module Port Traffic Terminal Port for GbE Interface 4.
1.2.2.10 GbE-A
1.2.2.11 XGbE-MV
➀ OUT IN 1 SFP+ Module Port Traffic Terminal for 10GbE [SR/LR/ER] Interface.
1.2.3.1 CWDMFA
1.2.3.2 CWDMFB
2. SPECIFICATION
1000BASE-SX/LX/CWDM 1.25 Gbps LC (SFP Module) 2 on GbE-A (up to 8 ports per IDU)
[802.3]
4 on GbE4f-AV (up to 16 ports per IDU)
10/100/1000BASE-T/TX (TX) 125 Mbps RJ-45 2 on GbE-A (up to 8 ports per IDU)
(T) 10 Mbps 4 on GbE4f-AV (up to 16 ports per IDU)
2.1.2 E1 Interface
INTERFACE SPEC CONNECTOR SUPPORTING CARD
HDB-3 [G.703] 16 × E1 (2.048 Mbps) MDR68 16 on 16E1-A (up to 224 ports per
IDU)
75 ohms, 120 ohms (selectable)
S-1.1 / L-1.1 [G.957] 2 × 155.52 Mbps LC (SFP Module) 2 on STM1-A Through (up to 28
ports per IDU)
CWDM
IF (IDU-ODU Interface) –48 V DC, TX IF, TNC 1 on MODEM-A/EA/EV (up to 12 ports per IDU)
RX IF, ODU SV
1 on MODEM-AV (up to 8 ports per IDU)
1 (NE1) on TERM-MV
Radio Capacity
Modulation
CS: 7 MHz CS: 14 MHz CS: 28 MHz CS: 40 MHz CS: 56 MHz
Radio Capacity
Modulation
CS: 7 MHz CS: 14 MHz CS: 28 MHz CS: 40 MHz CS: 56 MHz
Radio Capacity
Modulation
CS: CS: CS: CS: CS: CS: CS:
7 MHz 14 MHz 28 MHz 40 MHz 56 MHz 80 MHz 112 MHz
Customer Bridge
Up to 15 per C-Bridge Instance
(in C-Bridge Instance)
2.2.4 MPLS-TP
Functions Supported Items
2.2.6 Synchronization
Functions Supported Items
★: The maximum number of the ports differs depending on the specified PTP Message Rate value.
Contact NEC for the further information.
2.3.1 STM-1
ITEM SPECIFICATIONS
Minimum Mean Launched Power –28 dBm –34 dBm –34 dBm
Others
2.3.2 1000BASE-X
ITEM SPECIFICATIONS
Minimum Mean Launched Power –17 dBm –19 dBm –22 dBm
Others
2.3.3 10GBASE-R
ITEM SPECIFICATIONS
SMSR —— 30 dB 30 dB
Maximum Mean Launched Power –2.8 dBm 0.5 dBm 4.0 dBm
Minimum Mean Launched Power –7.3 dBm –8.2 dBm –4.7 dBm
Minimum Mean Launched Power –9.9 dBm –14.4 dBm –15.8 dBm
Others
3. SYSTEM PERFORMANCES
3.1.1 IDU/MDP
POWER DIMENSIONS
Ref. OBJECT WEIGHT DESCRIPTION
CONSUMPTION [W × H × D] mm
POWER DIMENSIONS
Ref. OBJECT WEIGHT DESCRIPTION
CONSUMPTION [W × H × D] mm
POWER DIMENSIONS
Ref. OBJECT WEIGHT DESCRIPTION
CONSUMPTION [W × H × D] mm
CWDMF Box
18 —— 433 × 32 × 200 1.2 kg Supporting Frame for CWDM
Mount
3.2.1 Temperature
Condition Requirements
Operating –5 to +50°C
Reference: –5 to+45°C by ETSI EN 300 019-1-3
Class 3.1E in the EU market
3.2.2 Humidity
Condition Requirements
Condition Requirements
here
The rated current for iPASOLINK VR 10, which previously was 23 Amperes, has
been changed to 27 Amperes since July 2016 due to newly added systems and
functions.
3.4 Others
Category Standards Conforming to:
EMF EN 50385