GGS-000376-08E

November 2017

iPASOLINK VR 10
SPECIFICATIONS

NEC Corporation
7-1, Shiba 5-Chome, Minato-Ku, Tokyo 108-8001, Japan

2018-05-23 METCO © NEC Corporation 2015-2017


GGS-000376-08E

© 2015 – 2017 by NEC Corporation

GGS-000376-08E
Printed in Japan

2018-05-23 METCO © NEC Corporation 2015-2017


CONTENTS –i–

iPASOLINK VR 10
SPECIFICATIONS

CONTENTS

1. INTERFACES 1-1

1.1 iPASOLINK VR 10 and Designated Slots . . . . . . . . . . . . . . . . . . . . . . . 1-1


1.1.1 Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
1.1.2 Card Slots on iPASOLINK VR 10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
1.2 Location of Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
1.2.1 Fundamental Cards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
1.2.1.1 MC-MV (Main Card) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
1.2.1.2 TERM-MV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
1.2.1.3 PS-MV (Power Supply) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
1.2.1.4 FAN-MV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
1.2.2 Cards for Universal Slots. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
1.2.2.1 MODEM-A/EA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
1.2.2.2 MODEM-AV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
1.2.2.3 MODEM-EV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
1.2.2.4 MSE-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
1.2.2.5 AUX-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
1.2.2.6 STM1-A THROUGH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
1.2.2.7 16E1-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
1.2.2.8 GbE4e-AV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
1.2.2.9 GbE4f-AV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
1.2.2.10 GbE-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8
1.2.2.11 XGbE-MV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8
1.2.3 CWDM Filter Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
1.2.3.1 CWDMFA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
1.2.3.2 CWDMFB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9

2. SPECIFICATION 2-1

2.1 Interface Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1


2.1.1 Ethernet Traffic Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2.1.2 E1 Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1

iPASOLINK VR 10: SPECIFICATIONS GGS-000376-08E


November 2017

2018-05-23 METCO © NEC Corporation 2015-2017


– ii/END – CONTENTS

2.1.3 STM-1 Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1


2.1.4 Radio Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.1.5 Management Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.1.6 Housekeeping Control and Alarm Interface . . . . . . . . . . . . . . . . . . . . . . 2-2
2.1.7 Other Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.2 Supported Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
2.2.1 Radio Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
2.2.1.1 Modulation and Radio Capacity — MODEM-A . . . . . . . . . . . . . . . 2-4
2.2.1.2 Modulation and Radio Capacity — MODEM-EA/EV . . . . . . . . . . . 2-4
2.2.1.3 Modulation and Radio Capacity — MODEM-AV . . . . . . . . . . . . . . 2-5
2.2.2 TDM Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
2.2.3 ETH Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
2.2.4 MPLS-TP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
2.2.5 Management Plane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
2.2.6 Synchronization. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
2.2.7 Performance Monitor and Logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
2.3 Traffic Interface Specifications and Standards . . . . . . . . . . . . . . . . . . 2-9
2.3.1 STM-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9
2.3.2 1000BASE-X . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10
2.3.3 10GBASE-R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11

3. SYSTEM PERFORMANCES 3-1

3.1 Power Consumption and Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1


3.1.1 IDU/MDP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
3.1.2 Fundamental Cards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
3.1.3 Cards for Universal Slots. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
3.2 Environmental Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
3.2.1 Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
3.2.2 Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
3.3 Power Line Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
3.3.1 Input Voltage and Connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
3.3.2 Rated Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
3.4 Others. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5

GGS-000376-08E iPASOLINK VR 10: SPECIFICATIONS

2018-05-23 METCO © NEC Corporation 2015-2017


INTERFACES 1-1

1. INTERFACES

1.1 iPASOLINK VR 10 and Designated Slots

1.1.1 Front View

1.1.2 Card Slots on iPASOLINK VR 10

Universal Slot #1 Universal Slot #2 Universal Slot #3 Universal Slot #4

Universal Slot #5 Universal Slot #6 Universal Slot #7 Universal Slot #8 FAN1

Universal Slot #9 MAIN CARD 1 Main Card Slot #1

Universal Slot #10 Main Card Slot #2

Universal Slot #11 Universal Slot #12 Universal Slot #13 Universal Slot #14 FAN2

TERM PS 1 PS Slot #2

Slots for fundamental cards that must be mounted.

Slot # Slots for option cards, which can be left vacant.


PS Power Supply

iPASOLINK VR 10: SPECIFICATIONS GGS-000376-08E

2018-05-23 METCO © NEC Corporation 2015-2017


1-2 INTERFACES

1.2 Location of Terminals

1.2.1 Fundamental Cards

1.2.1.1 MC-MV (Main Card)


 Required one, up to two Main Cards can be mounted per IDU.

➀ ➁ ➂ ➃ ➄

Ref. # Indication Element Description

➀ EOW Pin Jack Connecting terminal for OW Headset.

➁ CALL Push Button Press the button to call the opposing site by OW.

➂ PROTECT Rocker Switch Switch to manage OOS (Out Of Service)

➃ MEM USB Type-A Connecting terminal for USB memory device. (Supporting
a memory device only.)

➄ LCT RJ-45 Connector Ethernet port for connecting WebLCT. (Supporting 10/
100BASE-TX; Auto-Negotiation, Auto-MDI/MDIX.)

1.2.1.2 TERM-MV
 Required one TERM-MV Card per IDU,

➀ ➁ ➂

CLK

Ref. # Indication Element Description

➀ NMS RJ-45 Connector Terminal for connecting to upstream of DCN Network.

➁ NE1 RJ-45 Connector Terminal for connecting to downstream of DCN Network.

➂ CLK High Density D-Sub Terminal for Clock Signal input/output. (15 pins)
Connector

GGS-000376-08E IPASOLINK VR 10: SPECIFICATIONS

2018-05-23 METCO © NEC Corporation 2015-2017


INTERFACES 1-3

1.2.1.3 PS-MV (Power Supply)


 Required one, up to two PS-MV Cards can be mounted per IDU.

Ref. # Indication Element Description

➀ PWR / SELV D3100 S Connector Terminal for –48 V DC power supply. Use the Safety Extra
Low Voltage (SELV). One or two PS-MV Cards can be
mounted.

1.2.1.4 FAN-MV
 Required two FAN MV Cards per IDU.

Standard Type High-Powered Type Standard Type


(Original) (Remodeled) (Remodeled)

Ref. # Indication Element Description

—— —— —— FAN-MV provides no front-accessing terminals. One or


two FAN-MV Cards can be mounted.

iPASOLINK VR 10: SPECIFICATIONS GGS-000376-08E

2018-05-23 METCO © NEC Corporation 2015-2017


1-4 INTERFACES

1.2.2 Cards for Universal Slots

1.2.2.1 MODEM-A/EA

 Available Slots: Restricted (Slots #1 to #8, #11 to #14)

➀ ➁ ➂ ➃

Ref. # Indication Element Description

➀ IF TNC Connector IF Terminal connecting to the Outdoor Unit (ODU).

➁ Cross Slot Screw Grounding terminal; screw shaft diameter is 4 mm.

➂ XIF IEC-MIN Connector Connecting terminals for configuring XPIC.

➃ MD/ODU PWR Toggle Switch Switch to supply power to MODEM and ODU.

1.2.2.2 MODEM-AV

 Available Slots: Restricted (Slots #1 to #8)

➀ ➁ ➂

Ref. # Indication Element Description

➀ IF TNC Connector IF Terminal connecting to the Outdoor Unit (ODU).

➁ Cross Slot Screw Grounding terminal; screw shaft diameter is 4 mm.

➂ MD/ODU PWR Toggle Switch Switch to supply power to MODEM and ODU.

GGS-000376-08E IPASOLINK VR 10: SPECIFICATIONS

2018-05-23 METCO © NEC Corporation 2015-2017


INTERFACES 1-5

1.2.2.3 MODEM-EV

 Available Slots: Restricted (Slots #1 to #8, #11 to #14)

➀ ➁ ➂

Ref. # Indication Element Description

➀ IF TNC Connector IF Terminal connecting to the Outdoor Unit (ODU).

➁ Cross Slot Screw Grounding terminal; screw shaft diameter is 4 mm.

➂ MD/ODU PWR Toggle Switch Switch to supply power to MODEM and ODU.

1.2.2.4 MSE-A
 Available Slots: Up to One MSE-A Card per IDU in Any Universal Slots
(#1 to #14)

Ref. # Indication Element Description

—— —— —— MSE-A Card provides no front-accessible terminals.

1.2.2.5 AUX-A
 Available Slots: Up to One AUX-A Card per IDU in Any Universal Slots
(#1 to #14)

Ref. # Indication Element Description

ALM/EOW/NE2 High-Density D-Sub Terminal for Housekeeping and Cluster alarms. Four input
44 Connector channels, six output channels. (44 pins)
➀ NOTE: The uses of EOW and NE1 interfaces are currently
not available.

iPASOLINK VR 10: SPECIFICATIONS GGS-000376-08E

2018-05-23 METCO © NEC Corporation 2015-2017


1-6 INTERFACES

1.2.2.6 STM1-A THROUGH

 Available Slots: All Universal Slots (#1 to #14)

SFP Module Ports ➀ ➁ CLASS 1 LASER PRODUCT

Ref. # Indication Element Description

➀ OUT IN 1 SFP Module Port STM-1 Optical Port 1; using SFP.

➁ OUT IN 2 SFP Module Port STM-1 Optical Port 2; using SFP.

1.2.2.7 16E1-A

 Available Slots: All Universal Slots (#1 to #14)

Ref. # Indication Element Description

➀ 2M IN/OUT MDR Connector E1 Traffic Signal Input/Output

GGS-000376-08E IPASOLINK VR 10: SPECIFICATIONS

2018-05-23 METCO © NEC Corporation 2015-2017


INTERFACES 1-7

1.2.2.8 GbE4e-AV

 Available Slots: Restricted (Slots #9, 10, 11, 12)

➀ ➁ ➂ ➃

Ref. # Indication Element Description

➀ OUT IN 1 RJ-45 Connector Traffic Terminal for GbE Interface 1.

➁ OUT IN 2 RJ-45 Connector Traffic Terminal for GbE Interface 2.

➂ OUT IN 3 RJ-45 Connector Traffic Terminal for GbE Interface 3.

➃ OUT IN 4 RJ-45 Connector Traffic Terminal for GbE Interface 4.

1.2.2.9 GbE4f-AV

 Available Slots: Restricted (Slots #9, 10, 11, 12)

➀ ➁ ➂ ➃ CLASS 1 LASER PRODUCT

Ref. # Indication Element Description

➀ OUT IN 1 SFP Module Port Traffic Terminal Port for GbE Interface 1.

➁ OUT IN 2 SFP Module Port Traffic Terminal Port for GbE Interface 2.

➂ OUT IN 3 SFP Module Port Traffic Terminal Port for GbE Interface 3.

➃ OUT IN 4 SFP Module Port Traffic Terminal Port for GbE Interface 4.

iPASOLINK VR 10: SPECIFICATIONS GGS-000376-08E

2018-05-23 METCO © NEC Corporation 2015-2017


1-8 INTERFACES

1.2.2.10 GbE-A

 Available Slots: Restricted (Slots #9 to #12)

➀ ➁ ➂ ➃ CLASS 1 LASER PRODUCT

Ref. # Indication Element Description

➀ 1 RJ-45 Connector Traffic Terminal for FE/GbE Interface.

➁ 2 RJ-45 Connector Traffic Terminal for FE/GbE Interface.

➂ 3 SFP Module Port Traffic Terminal for GbE Interface.

➃ 4 SFP Module Port Traffic Terminal for GbE Interface.

1.2.2.11 XGbE-MV

 Available Slots: Restricted (Slots #13 and #14)

➀ CLASS 1 LASER PRODUCT

Ref. # Indication Element Description

➀ OUT IN 1 SFP+ Module Port Traffic Terminal for 10GbE [SR/LR/ER] Interface.

GGS-000376-08E IPASOLINK VR 10: SPECIFICATIONS

2018-05-23 METCO © NEC Corporation 2015-2017


INTERFACES 1-9

1.2.3 CWDM Filter Box

1.2.3.1 CWDMFA

CLASS 1 LASER PRODUCT ➀ ➁


CLASS 1M LASER PRODUCT

Ref. # Indication Element Description

➀ OUT IN SFP Module Port Traffic Terminal for GbE Interface.

➁ CWDM LC Connector Traffic Terminal for CWDM Interface.

1.2.3.2 CWDMFB

CLASS 1 LASER PRODUCT ➀ ➁


CLASS 1M LASER PRODUCT

Ref. # Indication Element Description

➀ OUT IN SFP Module Port Traffic Terminal for GbE Interface.

➁ CWDM LC Connector Traffic Terminal for CWDM Interface.

iPASOLINK VR 10: SPECIFICATIONS GGS-000376-08E

2018-05-23 METCO © NEC Corporation 2015-2017


1-10/END INTERFACES

This page is intentionally left blank.

GGS-000376-08E iPASOLINK VR 10: SPECIFICATIONS

2018-05-23 METCO © NEC Corporation 2015-2017


SPECIFICATION 2-1

2. SPECIFICATION

2.1 Interface Capacity

iPASOLINK VR 10 supports various interfaces conforming to the ITU-T Standards


and IEEE Standards:

2.1.1 Ethernet Traffic Interfaces


INTERFACE SPEC CONNECTOR SUPPORTING CARD

10GBASE-SR/LR/ER 10 Gbps LC (SFP+ Module) 1 on XGbE (up to 2 ports per IDU)

1000BASE-SX/LX/CWDM 1.25 Gbps LC (SFP Module) 2 on GbE-A (up to 8 ports per IDU)
[802.3]
4 on GbE4f-AV (up to 16 ports per IDU)

10/100/1000BASE-T/TX (TX) 125 Mbps RJ-45 2 on GbE-A (up to 8 ports per IDU)
(T) 10 Mbps 4 on GbE4f-AV (up to 16 ports per IDU)

2.1.2 E1 Interface
INTERFACE SPEC CONNECTOR SUPPORTING CARD

HDB-3 [G.703] 16 × E1 (2.048 Mbps) MDR68 16 on 16E1-A (up to 224 ports per
IDU)
75 ohms, 120 ohms (selectable)

2.1.3 STM-1 Interface


INTERFACE SPEC CONNECTOR SUPPORTING CARD

S-1.1 / L-1.1 [G.957] 2 × 155.52 Mbps LC (SFP Module) 2 on STM1-A Through (up to 28
ports per IDU)
CWDM

iPASOLINK VR 10: SPECIFICATIONS GGS-000376-08E

2018-05-23 METCO © NEC Corporation 2015-2017


2-2 SPECIFICATION

2.1.4 Radio Interface


INTERFACE SPEC CONNECTOR DESCRIPTION

IF (IDU-ODU Interface) –48 V DC, TX IF, TNC 1 on MODEM-A/EA/EV (up to 12 ports per IDU)
RX IF, ODU SV
1 on MODEM-AV (up to 8 ports per IDU)

2.1.5 Management Interface


INTERFACE SPEC CONNECTOR DESCRIPTION

10/100BAE-T/TX (TX) 125 Mbps RJ-45 1 (LCT) on MC-MV


(T) 10 Mbps
1 (NMS) on TERM-MV

1 (NE1) on TERM-MV

2.1.6 Housekeeping Control and Alarm Interface


INTERFACE SPEC CONNECTOR DESCRIPTION

AUX Input Photo Coupler D-Sub 44 4 Inputs on AUX-A; for


Housekeeping Alarms

AUX Output Photo Coupler D-Sub 44 6 Outputs on AUX-A; for


Housekeeping Controls

2.1.7 Other Interfaces


INTERFACE SPEC CONNECTOR DESCRIPTION

Oderwire Headset 4-Wire Voice Channel Pin Jack 1 (EOW) on MC-MV

External Storage USB Type-A Female 1 (MEM) on MC-MV

GGS-000376-08E IPASOLINK VR 10: SPECIFICATIONS

2018-05-23 METCO © NEC Corporation 2015-2017


SPECIFICATION 2-3

2.2 Supported Functions


iPASOLINK VR 10 supports the following functions:

2.2.1 Radio Functions


Functions Supported Items

Channel Spacing MODEM-A


MODEM-EA 7 MHz, 14 MHz, 28 MHz, 40 MHz, 56 MHz
MODEM-EV

MODEM-AV 7 MHz, 14 MHz, 28 MHz, 40 MHz, 56 MHz, 80 MHz, 112 MHz

Modulation MODEM-A 7 Modulation Schemes are changeable: QPSK, 16QAM,


32QAM, 64QAM, 128QAM, 256QAM, 512QAM

MODEM-EA 9 Modulation Schemes are changeable: QPSK, 16QAM,


MODEM-EV 32QAM, 64QAM, 128QAM, 256QAM, 512QAM, 1024QAM,
2048QAM

MODEM-AV 10 Modulation Schemes are changeable: QPSK, 16QAM,


32QAM, 64QAM, 128QAM, 256QAM, 512QAM, 1024QAM,
2048QAM, 4096QAM

Configuration 1+0 MODEM-A


MODEM-EA Up to 12 systems per IDU
MODEM-EV

MODEM-AV Up to 8 systems per IDU

1+1 SWG MODEM-A


MODEM-EA Up to 6 Switch Groups per IDU
MODEM-EV

MODEM-AV Up to 4 Switch Groups per IDU

RTA Group MODEM-A


MODEM-EA Up to 8 configurations per IDU
MODEM-EV

MODEM-AV Up to 4 configurations per IDU

1+0 XPIC MODEM-A


Group MODEM-EA Up to 6 configurations per IDU
MODEM-EV

MODEM-AV Up to 4 configurations per IDU

1+1 XPIC MODEM-A


Group MODEM-EA Up to 3 configurations per IDU
MODEM-EV

MODEM-AV Up to 2 configurations per IDU

iPASOLINK VR 10: SPECIFICATIONS GGS-000376-08E

2018-05-23 METCO © NEC Corporation 2015-2017


2-4 SPECIFICATION

2.2.1.1 Modulation and Radio Capacity — MODEM-A

Radio Capacity
Modulation
CS: 7 MHz CS: 14 MHz CS: 28 MHz CS: 40 MHz CS: 56 MHz

512QAM 50MB 100MB 200MB 300MB 400MB

256QAM 50MB 100MB 200MB 300MB 400MB

128QAM 50MB 100MB 150MB 200MB 300MB

64QAM 50MB 100MB 150MB 150MB 300MB

32QAM 50MB 50MB 100MB 150MB 200MB

16QAM 50MB 50MB 100MB 100MB 200MB

QPSK 50MB 50MB 50MB 50MB 100MB

2.2.1.2 Modulation and Radio Capacity — MODEM-EA/EV

Radio Capacity
Modulation
CS: 7 MHz CS: 14 MHz CS: 28 MHz CS: 40 MHz CS: 56 MHz

2048QAM N/A 100MB 300MB 400MB 500MB

1024QAM 50MB 100MB 200MB 300MB 500MB

512QAM 50MB 100MB 200MB 300MB 400MB

256QAM 50MB 100MB 200MB 300MB 400MB

128QAM 50MB 100MB 150MB 200MB 300MB

64QAM 50MB 100MB 150MB 150MB 300MB

32QAM 50MB 50MB 100MB 150MB 200MB

16QAM 50MB 50MB 100MB 100MB 200MB

QPSK 50MB 50MB 50MB 50MB 100MB

GGS-000376-08E IPASOLINK VR 10: SPECIFICATIONS

2018-05-23 METCO © NEC Corporation 2015-2017


SPECIFICATION 2-5

2.2.1.3 Modulation and Radio Capacity — MODEM-AV

Radio Capacity
Modulation
CS: CS: CS: CS: CS: CS: CS:
7 MHz 14 MHz 28 MHz 40 MHz 56 MHz 80 MHz 112 MHz

4096QAM N/A N/A 300MB 400MB 600MB N/A N/A

2048QAM N/A 100MB 300MB 400MB 500MB 600MB 1000MB

1024QAM 50MB 100MB 200MB 300MB 500MB 600MB 800MB

512QAM 50MB 100MB 200MB 300MB 400MB 600MB 800MB

256QAM 50MB 100MB 200MB 300MB 400MB 500MB 600MB

128QAM 50MB 100MB 150MB 200MB 300MB 500MB 600MB

64QAM 50MB 100MB 150MB 150MB 300MB 400MB 500MB

32QAM 50MB 50MB 100MB 150MB 200MB 300MB 500MB

16QAM 50MB 50MB 100MB 100MB 200MB 300MB 400MB

QPSK 50MB 50MB 50MB 50MB 100MB 100MB 200MB

2.2.2 TDM Functions


Functions Supported Items

Crossconnect Terminal Point 16E1-A Up to 16 per card, up to 224 per IDU


(E1 Channel)
STM1-A Up to 63 per card, up to 882 per IDU

MODEM-A/EA/EV Up to 152 per card, up to 1824 per IDU

MODEM-AV Up to 152 per card, u to 1216 per IDU

MSE-A Up to 64 per card, up to 128 per IDU

Crossconnect Terminal Point STM1-A Up to 2 per card, up to 28 per IDU


(STM-1 Channel)
MODEM-A/EA/EV Up to 2 per card, up to 24 per IDU

MODEM-AV Up to 2 per card, up to 16 per IDU

Crossconnect Capacity E1 Channel 2-Way Up to 975 per IDU


[(12 × MODEM-152CH) + (2 × STM1-A-63CH)]  2

iPASOLINK VR 10: SPECIFICATIONS GGS-000376-08E

2018-05-23 METCO © NEC Corporation 2015-2017


2-6 SPECIFICATION

2.2.3 ETH Functions

Functions Supported Items

VLAN VLAN ID Up to 4094 per IDU

C-Bridge Instance Up to 16 per IDU

Customer Bridge
Up to 15 per C-Bridge Instance
(in C-Bridge Instance)

VLAN Swap Up to 256 per IDU

FDB All Entries


Up to 32K per IDU
(Dynamic + Static)

Static Entries Up to 256 per IDU

Filter Ingress Filter Up to 16 per IDU

Egress Filter Up to 16 per IDU

Filter Rules (L2/L3) Up to 512 per IDU

QoS (VLAN Based) VLAN Group Up to 8 per IDU

Up to 4095 VLANs per VLAN Group

Priority Shaper Up to 8 per IDU

Mapping Table Up to 16 per IDU

QoS (Port Based) Classification Profile Up to 16 per IDU

Policer Policer Instance Up to 256 per IDU

Policer Rate Profiler Up to 64 per IDU

ETH OAM MEG Instances Up to 128 per IDU

MEP Instances Up to 128 per IDU

Peer MEP Up to 32 per IDU

Ethernet Ring Ring Index Up to 16 per IDU

RSTP/MSTP MSTI Up to 4 per Instances

Link Aggregation LAG Member Up to 8 per LAG

LAG Instance Up to 8 per IDU

GGS-000376-08E IPASOLINK VR 10: SPECIFICATIONS

2018-05-23 METCO © NEC Corporation 2015-2017


SPECIFICATION 2-7

2.2.4 MPLS-TP
Functions Supported Items

E2E (End-to-End) Path Channel PW Up to 128 per IDU

Path LSP Up to 2048 per IDU

XC Up to 1024 per IDU

Linear Protection E2E LSP Up to 128 per IDU

MPLS-TP OAM MEG Up to 128 per IDU


[G.8113.1]
MEP LSP MEP Up to 128 per IDU

Peer MEP Up to 128 per IDU

MIP Up to 64 per IDU

2.2.5 Management Plane


Functions Supported Items

Inband Management VLAN Inband Interface Up to 4 per IDU

NMS Management VLAN NMS Port Up to 4 per IDU

Software Bridge Software Bridge ID Up to 8 per IDU

User Account User Account Up to 100 per IDU

ARP ARP Cache Up to 1024 per IDU

Static ARP Up to 256 per IDU

Routing Static Route Up to 128 per IDU

NTP NTP Server Up to 4 per IDU

DHCP DHCP Server Up to 3 per IDU

DHCP Relay Up to 4 per IDU

SNMP SNMP Community Up to 10 IDU

SNMP Trap Up to 3 per IDU

RADIUS RADIUS Server Up to 3 per IDU

iPASOLINK VR 10: SPECIFICATIONS GGS-000376-08E

2018-05-23 METCO © NEC Corporation 2015-2017


2-8 SPECIFICATION

2.2.6 Synchronization
Functions Supported Items

Timing Source Up to 3 per IDU

PTP Port Entry Up to 26 Physical Ports per IDU★


BC [1588v2/G.8275.1]
SOOC [G.8265.1] Master Entry Up to 5 Physical Ports per IDU★

★: The maximum number of the ports differs depending on the specified PTP Message Rate value.
Contact NEC for the further information.

2.2.7 Performance Monitor and Logs


Functions Supported Items

Log History Log Command, Event, Alarm


Up to 8,000 items per system

PM 15-Min History (Instance)

1-Day History (Instance)

VLAN Counter Up to 256 per IDU

LSP Counter Up to 256 per IDU

GGS-000376-08E IPASOLINK VR 10: SPECIFICATIONS

2018-05-23 METCO © NEC Corporation 2015-2017


SPECIFICATION 2-9

2.3 Traffic Interface Specifications and Standards

2.3.1 STM-1
ITEM SPECIFICATIONS

Nominal Bit Rate 155.520 Mbit/s

Application Code [ITU-T G.957] S-1.1 L-1.1 CWDM

Transmitter at Reference Point S

Operating Wavelength Range 1261 to 1360 nm 1263 to 1360 nm 1471 to 1611 nm

Maximum Mean Launched Power –8 dBm 0 dBm 5 dBm

Minimum Mean Launched Power –15 dBm –5 dBm 0 dBm

Minimum Extinction Ratio (dB) 8.2 dB or more 10 dB or more 10 dB or more

Receiver at Reference Point R

Operating Wavelength Range 1261 to 1360 nm 1263 to 1360 nm 1260 to 1620 nm

Maximum Mean Launched Power –8 dBm –10 dBm –3 dBm

Minimum Mean Launched Power –28 dBm –34 dBm –34 dBm

Others

Type of Fiber Cable SMF

Connector LC Connector using SFP

iPASOLINK VR 10: SPECIFICATIONS GGS-000376-08E

2018-05-23 METCO © NEC Corporation 2015-2017


2-10 SPECIFICATION

2.3.2 1000BASE-X
ITEM SPECIFICATIONS

Application IEEE802.3 Full Duplex

1000BASE-SX 1000BASE-LX CWDM

Nominal Bit Rate 1250 Mbit/s

Coding Method 8B/10B

Transmitter at Reference Point S

Operating Wavelength Range 770 to 860 nm 1270 to 1355 nm 1471 to 1611 nm

SMSR 0.85 dB (RMS) 4 dB (RMS) 5 dB

Maximum Mean Launched Power 0 dBm –3 dBm 5 dBm

Minimum Mean Launched Power –9.5 dBm –11 dBm 0 dBm

Minimum Extinction Ratio (dB) 9 dB or more 9 dB or more 9 dB or more

Receiver at Reference Point R

Operating Wavelength Range 770 to 860 nm 1270 to 1355 nm 1260 to 1620 nm

Maximum Mean Launched Power 0 dBm –3 dBm –3 dBm

Minimum Mean Launched Power –17 dBm –19 dBm –22 dBm

Others

Target Distance 550 m 5 km 40 km or longer

Type of Fiber Cable MMF: GI Cable SMF: SI Cable


(Core/Clad dia.: 50/125 µm) (Core/Clad dia.: 9/125 µm)

Connector LC Connector using SFP

GGS-000376-08E IPASOLINK VR 10: SPECIFICATIONS

2018-05-23 METCO © NEC Corporation 2015-2017


SPECIFICATION 2-11

2.3.3 10GBASE-R

ITEM SPECIFICATIONS

Application IEEE802.3 Full Duplex

10GBASE-SR 10GBASE-LR 10GBASE-ER

Nominal Bit Rate 10.3125 Gbit/s

Coding Method 64B/66B

Transmitter at Reference Point S

Operating Wavelength Range 840 to 860 nm 1260 to 1355 nm 1530 to 1565 nm

SMSR —— 30 dB 30 dB

Maximum Mean Launched Power –2.8 dBm 0.5 dBm 4.0 dBm

Minimum Mean Launched Power –7.3 dBm –8.2 dBm –4.7 dBm

Minimum Extinction Ratio (dB) 3 dB 3.5 dB or more 3.0 dB

Receiver at Reference Point R

Operating Wavelength Range 840 to 860 nm 1260 to 1355 nm 1530 to 1565 nm

Maximum Mean Launched Power –1 dBm 0.5 dBm –1.0 dBm

Minimum Mean Launched Power –9.9 dBm –14.4 dBm –15.8 dBm

Others

Target Distance 300 m 10 km 40.km

Type of Fiber Cable MMF: Core/Clad SMF: Core/Clad SMF: Core/Clad


(dia. 50/125 µm) (dia. 9/125 µm) (dia. 9/125 µm)

Connector LC Connector using SFP+

iPASOLINK VR 10: SPECIFICATIONS GGS-000376-08E

2018-05-23 METCO © NEC Corporation 2015-2017


2-12/END SPECIFICATION

This page is intentionally left blank.

GGS-000376-08E iPASOLINK VR 10: SPECIFICATIONS

2018-05-23 METCO © NEC Corporation 2015-2017


SYSTEM PERFORMANCES 3-1

3. SYSTEM PERFORMANCES

3.1 Power Consumption and Size

3.1.1 IDU/MDP

POWER DIMENSIONS
Ref. OBJECT WEIGHT DESCRIPTION
CONSUMPTION [W × H × D] mm

IDU 322 W 15 kg Fully installed (approx.)


1 483 × 129 × 230
——— 7.0 kg Chassis (vacant slots)

3.1.2 Fundamental Cards

POWER DIMENSIONS
Ref. OBJECT WEIGHT DESCRIPTION
CONSUMPTION [W × H × D] mm

2 MC-MV 26 W★ 300 × 22 × 220 0.7 kg Main Card

CLK-MV Installed on MC-MV;


3-1 3W 65 × 22 × 80 0.1 kg
(Type 001) 1588v2 BC/SOOC

CLK-MV Installed on MC-MV


3-2 1W 65 × 22 × 80 0.1 kg
(Type 002)

4 PS-MV —— 150 × 22 × 220 0.4 kg Power Supply

5 TERM-MV 3W 100 × 22 × 220 0.2 kg Term Card

FAN-MV Cooling Fan (Standard Type,


6-1 6W 30 × 66 × 220 0.6 kg
(Type 001/003) Original)

FAN-MV High-Powered Colling Fan (for Using


6-2 17 W 30 × 66 × 220 0.6 kg
(Type 002) MODEM-AV)

★: The value does not include that of SFP/SFP+ modules.

iPASOLINK VR 10: SPECIFICATIONS GGS-000376-08E

2018-05-23 METCO © NEC Corporation 2015-2017


3-2 SYSTEM PERFORMANCES

3.1.3 Cards for Universal Slots

POWER DIMENSIONS
Ref. OBJECT WEIGHT DESCRIPTION
CONSUMPTION [W × H × D] mm

7-1 MODEM-A 17 W 100 × 22 × 220 0.4 kg ODU Interface

7-2 MODEM-EA 14 W 100 × 22 × 220 0.4 kg ODU Interface

7-3 MODEM-EV 15 W 100 × 22 × 220 0.4 kg ODU Interface

7-4 MODEM-AV 35 W 100 × 22 × 220 0.5 kg ODU Interface

8 16E1-A 8W 100 × 22 × 220 0.4 kg 16 × E1 Interface

9 STM1-A 8 W★ 100 × 22 × 220 0.4 kg STM-1 Interface; Class 1 Product

GbE-A 4×GbE [2×SFP + 2×RJ45];


10-1 8 W★ 100 × 22 × 220 0.4 kg
Class 1 Product

10-2 GbE4e-AV 8W 100 × 22 × 220 0.4 kg 4 × GbE [4 × RJ45]

10-3 GbE4f-AV 8 W★ 100 × 22 × 220 0.4 kg 4 × XGbE [SFP]; Class 1 Product

11 XGbE-MV 8 W★ 100 × 22 × 220 0.4 kg 1 × XGbE [SFP+]; Class 1 Product

12 MSE-A 10 W 100 × 22 × 220 0.4 kg Multi Service Engine for PWE

13 AUX-A 3W 100 × 22 × 220 0.4 kg Auxiliary Input/Output Interface

14 SFP+ 2W 14 × 10 × 57 0.015 kg On XGbE Ports

15 SFP 1W 14 × 10 × 57 0.015 kg On STM-1 Ports, GbE Ports

16 CWDMFA 0W 100 × 22 × 210 0.4 kg Class 1/1M Laser Product

17 CWDMFB 0W 100 × 22 × 210 0.4 kg Class 1/1M Laser Product

CWDMF Box
18 —— 433 × 32 × 200 1.2 kg Supporting Frame for CWDM
Mount

★: The value does not include that of SFP/SFP+ modules.

GGS-000376-08E iPASOLINK VR 10: SPECIFICATIONS

2018-05-23 METCO © NEC Corporation 2015-2017


SYSTEM PERFORMANCES 3-3

3.2 Environmental Conditions

3.2.1 Temperature

Condition Requirements

Operating –5 to +50°C
Reference: –5 to+45°C by ETSI EN 300 019-1-3
Class 3.1E in the EU market

Transportation –40 to +70°C (ETSI EN 300 019-1-2 Class 2.3)

Storage –25 to +55°C (ETSI EN 300 019-1-1 Class 1.2)

3.2.2 Humidity

Condition Requirements

Operating Up to 95% (at +50°C, no condensing)


Reference: ETSI EN 300 019-1-3 Class 3.1E in the
EU market

Transportation ETSI EN 300 019-1-2 Class 2.3

Storage ETSI EN 300 019-1-1 Class 1.2

iPASOLINK VR 10: SPECIFICATIONS GGS-000376-08E

2018-05-23 METCO © NEC Corporation 2015-2017


3-4 SYSTEM PERFORMANCES

3.3 Power Line Requirements

3.3.1 Input Voltage and Connector

Condition Requirements

Input Voltage Range –48 V DC (–40.5 to –57 V DC)


ETSI EN 300 132-2

Connector 10-Pin, 3.81 mm Pitch [1-178288-8]

3.3.2 Rated Current

Rated current is indicated on the equipment label:

here

The rated current for iPASOLINK VR 10, which previously was 23 Amperes, has
been changed to 27 Amperes since July 2016 due to newly added systems and
functions.

GGS-000376-08E iPASOLINK VR 10: SPECIFICATIONS

2018-05-23 METCO © NEC Corporation 2015-2017


SYSTEM PERFORMANCES 3-5

3.4 Others
Category Standards Conforming to:

Spectrum ETSI EN 302 217-2

EMC ETSI EN 301 489-1, ETSI EN 301 489-4

Safety EN 60950-1, EN 60950-22

EMF EN 50385

For details, please visit our DoC:


http://www.nec.com/en/global/prod/nw/pasolink/support/RED_DoC.html

iPASOLINK VR 10: SPECIFICATIONS GGS-000376-08E

2018-05-23 METCO © NEC Corporation 2015-2017


3-6/END SYSTEM PERFORMANCES

This page is intentionally left blank.

GGS-000376-08E iPASOLINK VR 10: SPECIFICATIONS

2018-05-23 METCO © NEC Corporation 2015-2017