Proton Plus is a critical care ventilator that offers a wide range of clinical ventilation modes and customizable settings to provide complete care for critical patients. It has modes like PRVC/VS, APRV, SIMV-VC/PS, SIMV-PC/PS, CPAP, Bi-NIV and auto modes like PSV-Auto and VS-Auto. The ventilator also displays lung dynamics curves and loops on a large 47cm TFT LED monitor and has special features like a nebulizer, manual breath function, and apnea backup ventilation.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
392 views2 pages
MAX Proton Plus
Proton Plus is a critical care ventilator that offers a wide range of clinical ventilation modes and customizable settings to provide complete care for critical patients. It has modes like PRVC/VS, APRV, SIMV-VC/PS, SIMV-PC/PS, CPAP, Bi-NIV and auto modes like PSV-Auto and VS-Auto. The ventilator also displays lung dynamics curves and loops on a large 47cm TFT LED monitor and has special features like a nebulizer, manual breath function, and apnea backup ventilation.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2
PROTON PLUS
Your reliable partner in patient ventilation
Catalogue No. AB/CAT/007 Version : 0.0 Date : 19/12/2014 Critical Care Ventilator with Wide Range of Clinical Solutions PROTON PLUS Complete Care to Critical Care Patients : Modes of Ventilation Volume Control Modes CMV - VC, ASSIST - VC, SIMV - VC/PS · PRVC/VS : Pressure Control Modes CMV - PC, ASSIST - PC, SIMV - PC/PS Guaranteed volume delivery with minimum airway pressure. Limits Advanced Modes PRVC/VS, APRV volutrauma. Prevents Hypoventilation. Assured minute volume. Non - Invasive Modes CPAP, Bi - NIV Enhanced patient safety. Reduced work of breathing. Auto Modes PSV - Auto, VS - Auto · APRV : Settable Parameters Breaths Per Minute (BPM) Up to 120 Allows Spontaneous ventilation to promote lung recruitment of Tidal Volume (VT) 20 to 300 cc Pediatric collapsed and poorly ventilated alveoli. Restores FRC. Better CO2 300 to 3000 cc Adult elimination. Improved oxygenation at lowest Ppeak and Pmean. Inspiratory Time (Ti) 0.2 to 4 sec Increased cardiac output. Peak Flow Rate 6 to 150 LPM Inspiratory Pressure Up to 80 cm of H2O · SIMV-VC/PS : PEEP 0 to 35 cm of H2O Ideal mode for weaning the patient. Ensures minimum minute volume. Inspiratory Pause 0 to 50% of Ti Permits pressure supported spontaneous breaths between two SIMV FiO2 21 to 100% breaths. Pressure Trigger -0.5 to -15 cm of H2O Flow Trigger 0.3 to 30 LPM · SIMV-PC/PS : Apnea Back-up Time 5 to 60 sec Offers ease of weaning for patients. Ensures additional safety against Measured Parameters barotrauma. Enhanced patient safety. Allows pressure supported No. of Breaths Spontaneous, Total Breaths per minute spontaneous breaths between consecutive SIMV breaths. Weaning Airway Pressure Peak, Plateau, Mean, PEEP strategy can be applied to number of breaths or pressure control limit. Patient Trigger Trigger Pressure, Trigger Flow Tidal Volume Inspired Volume, Expired Volume · CPAP & Bi-NIV-Non Invasive Ventilation : O2 Concentration Inspired FiO2 Allows spontaneous breathing offering maximum patient comfort. Lungs Mechanics Lung Compliance, Lung Resistance Ideal for supportive respiration requiring minimum overall intervention. Minute Volume Expired Minute Volume · VS-Auto : Alarms : Preset and Settable Combination mode with benefits of VS and PRVC. VS option allow Airway Pressure High, Low Inspired VT High, Low Pressure Supported, Volume Assured Spontaneous breaths. Backup FiO2 High, Low mode ensures assured minute volume with exposure to minimum Expired Volume Low airway pressure. Offers highest patient safety against volutrauma, PEEP High, Low Hypoventilation, abnormal airway pressure and apnic condition. Breaths Per Minute High Apnea Alarm Time 5 to 60 sec · PSV-Auto : Information on LCD Increase patient comfort level with low work of breathing makes it Parameters Dynamic Airway Pressure Indication perfect choice for weaning the patient. Backup mode enables breath Mode, BPM, Spont. BPM, VTi, VTe, PEEP, Ppeak, FiO2 delivery of mandatory breaths at controlled pressure ensuring patient Curves & Loops Airway Pressure v/s Time safety. Tidal Volume v/s Time Flow Rate v/s Time User Friendly Concept : Airway Pressure v/s Flow Rate · Dual Display Flow Rate v/s Tidal Volume Volume v/s Airway Pressure · Large display showing all lung dynamics simultaneously on same screen Display Size 47 cms TFT LED Monitor Curves : Airway Pressure V/s Time, Tidal Volume V/s Time, Special Features Flow Rate V/s Time · Nebulizer · O2 Enrichment Loops : Airway Pressure V/s Flow Rate, Tidal Volume V/s Airway · Manual Breath · Standby Function Pressure, Flow Rate V/s Tidal Volume · Tube Compensation · Inspiratory Hold · Apnea Backup Ventilation · Altitude Compensation · Easy and Quick setting Keyboard Electrical and Gas Supply Input Supply 175 - 260 Volts or 90 - 132 Volts AC, 50/60 Hz Economy of Operation : Internal Battery Backup 90 Minutes · Long Life Flow Sensor and FiO2 Sensor External Battery Backup 10 to 15 Volts DC (Optional) · Consumes least number of parts per patient. Power Consumption 70 Watts (Approx.) for Basic Ventilator · Designed and built to operate in harsh environment. Gas Input Medical Grade Air and O2 at 2.7 - 6 Bar (39-87 psi) · Low Operational Cost per Patient. Weight 15 Kgs. (only Ventilator, without Cart) Standard Accessories Breathing Circuit · Built to Last Long. Optional Accessories Humidifier, Medical Grade Compressor
Specifications are subject to change without prior notice. Accessories shown in image are optional and not the standard part of ventilator.