Side Flow VRF Catalogue 2019

Download as pdf or txt
Download as pdf or txt
You are on page 1of 36

Side Flow VRF


Utopia & Mini Set Free ranges
SIDE
FLOW

VRF
FIND THE SOLUTION

The Quick Selection Guide has all of the answers, all the HITACHI air
conditioning solutions that fit the requirements of each facility.
We help you choose the HITACHI product according to the connectible indoor
units, power, energy efficiency and economic proposal that guarantee the
highest comfort.

SET FREE SIGMA SET FREE SIGMA


UTOPIA CENTRIFUGAL UTOPIA
SET FREE SET FREE Modular High Modular Very
DATA PER OUTDOOR UNIT* MULTIZONE IVX COMFORT VRF IVX PREMIUM
MINI SIDE FLOW Seasonal High Seasonal
Performance Performance

Maximum number of
up to 6 up to 4 up to 6 up to 8 up to 12 up to 10 up to 64 up to 64
connectible indoor units

Maximum cooling capacity up to 17600 W up to 30000 W up to 24000 W up to 30000 W up to 15500 W up to 33500 W up to 268000 W up to 201000 W

Maximum cooling distance (real) up to 25 m up to 100 m up to 100 m up to 100 m up to 75 m up to 100 m up to 165 m up to 165 m

Maximum cooling distance


up to 25 m up to 125 m up to 125 m up to 125 m up to 90 m up to 125 m up to 190 m up to 190 m
(equivalent length)

AXIAL AXIAL AXIAL AXIAL AXIAL AXIAL AXIAL AXIAL


Fan type horizontal horizontal conductive horizontal horizontal horizontal vertical vertical
discharge discharge discharge discharge discharge discharge discharge discharge

Available static pressure NO NO 100 Pa~120 Pa NO NO NO up to 80 Pa up to 80 Pa

Independent control of the


YES YES YES YES YES YES YES YES
indoor units

Optional
YES YES YES YES YES YES YES
Centralized control (with PSC-6RAD
(bus H-LINK) (bus H-LINK) (bus H-LINK) (bus H-LINK) (bus H-LINK) (bus H-LINK) (bus H-LINK)
interface)

Energy efficiency level

Price level

VRF
R&D+i
BY
CONCEPT

CHOOSE THE INDOOR UNITS THAT BEST FIT


THE DECORATION AND NEEDS OF THE FACILITY
SIDE
FLOW

VRF
A RANGE FOR EACH APPLICATION NEEDS

UTOPIA COMFORT UTOPIA PREMIUM


COOLING: 7.10~30.00 KW COOLING: 5.00~30.00 KW
HEATING: 8.00~33.50 KW HEATING: 5.60~33.50 KW
4 DIFFERENT ZONES 8 DIFFERENT ZONES

3
INDEPENDENT CONTROL INDEPENDENT CONTROL

UTOPIA DX MINI SET FREE


Side Flow VRF

COOLING: 7.10~25.00 KW COOLING: 11.20~33.50 KW


HEATING: 8.00~28.00 KW HEATING: 12.50~37.50 KW
DEDICATED MODEL FOR AHU SYSTEMS 12 DIFFERENT ZONES
INDEPENDENT CONTROL
4
UP TO
UNITS
AIR CONDITIONING FOR
INDEPENDENT

S
OL
4 DIFFERENT SPACES

TR
N
O
C
IN D E NT
PENDE

WITH INDEPENDENT
CONTROL
MAXIMUM ACTUAL
COLD DISTANCE UP TO
100 M (125 M EQUIVALENT)

UP TO 6 HP COMPLIES WITH EUROPEAN


WITH A SINGLE FAN REGULATIONS LOT.11 AND
THE ERP TIER 2 DIRECTIVE
UTOPIA
IVX

COMFORT
UTOPIA IVX COMFORT

With the precision of a VRF


Ideal solution for light commercial
applications
Easy to install, because it is a flexible, compact and
lightweight solution, it reduces installation time by half.

High seasonal performance even at partial loads.


Capacity index between 90% and 115%.

Compatible with all HITACHI centralized control and


management systems.

Compatible
indoor units

5
• Cools up to 4 different spaces
• Independent control
• Different setpoint temperatures
• Different fan speeds
• Different work schedules (with a programmable control)
Side Flow VRF
OUTDOOR UNIT
INVERTER

UTOPIA IVX COMFORT
RAS - 3 ~ 6H(V)NC1E

Characteristics

UTOPIA IVX COMFORT in HITACHI’s simplified Optional DX-KIT


alternative to VRF Intended for the integration of air curtains and air
It is the perfect choice for air conditioning small and treatment units when required.
medium businesses, with highly demanding requirements.
Operation at extreme temperatures
High performance The best performance even at extreme temperatures, -20ºC
Maximum seasonal performance at partial loads, which in heating and at 46ºC in cooling.
generates energy conservation.
DC Inverter Compressor
Flexibility Increased performance at low speed thanks to the
Compatible with System Free indoor units that are transmission mechanism and refinement of the engine.
managed through all individual or centralized control
Air conditioning of 4 spaces
systems, with H - Link II option.
Air condition up to 4 different and independent spaces,
each indoor unit with its own control.
Guaranteed performance

+15 +46
-20 -15

UTOPIA IVX COMFORT SINGLE PHASE


Outdoor Units RAS-3HVNC1 RAS-4HVNC1E RAS-5HVNC1E RAS-6HVNC1E
Number of connected units (min-max) MONO-TWIN MONO-TWIN-TRI-QUADRI MONO-TWIN-TRI-QUADRI MONO-TWIN-TRI-QUADRI
Cooling 7.10 (3.20~8.00) 10.00 (4.50~11.20) 12.50 (5.70~14.00) 14.00 (6.00~16.00)
Nominal power(1)
Heating kW 8.00 (3.50~10.60) 11.20 (5.00~14.00) 14.00 (5.00~18.00) 16.00 (5.00~20.00)
Cooling 2.14 2.55 3.54 4.12
Absorbed nominal power
Heating 1.88 2.30 3.43 4.32
More information on next More information on next
EER - COP(2) page page
3.37 - 3.89 (A/A) 3.26 - 3.56 (A/B)

Sound pressure level (night mode) (3)


dB(A) 48 (46) 52 (50) 52 (50) 55 (53)
Airflow in heat m³/h 2682 3720 4080 4800
Power supply 1~230 V 50 H 1~230 V 50 H 1~230 V 50 H 1~230 V 50 H
Pipe diameter (Liq - Gas) inches 3/8 - 5/8 3/8 - 5/8 3/8 - 5/8 3/8 - 5/8
Maximum length m 50 70 75 75
Maximum height 30/20 30/20 30/20 30/20
Initial refrigerant charge kg(m) /
1.9 (20) - 3.97 3.2 (30) - 6.68 3.2 (30) - 6.68 3.2 (30) - 6.68
(maximum length of pipes) GWP eq Ton
Additional refrigerant charge g/m 40 40 60 60
Refrigerant R410A
Compressor SCROLL DC INVERTER

UTOPIA IVX COMFORT THREE-PHASE


Outdoor Units RAS-4HNC1E RAS-5HNC1E RAS-6HNC1E RAS-8HNCE RAS-10HNCE RAS-12HNC
Possible Combinations MONO - TWIN- TRI- QUADRI
Cooling 10.00 (4.50~11.20) 12.50 (5.70~14.00) 14.00 (6.00~16.00) 20.00 (8.00~22.40) 25.00 (10.00~28.00) 30.00 (11.20~33.50)
Nominal power (1)
Heating kW 11.20 (5.00~14.00) 14.00 (5.00~18.00) 16.00 (5.00~20.00) 22.40 (6.30~28.00) 28.00 (8.00~35.00) 33.50 (9.00~37.50)
Cooling 2.55 3.54 4.12 5.69 8.02 11.05
Absorbed nominal power
Heating 2.30 3.43 4.32 5.62 7.45 8.96

7
More information on
EER - COP(2) next page
3.37 - 3.89 (A/A) 3.26 - 3.56 (A/B) 3.36 - 3.81 (A/A) 3.02 - 3.63 (B/A) 2.57 - 3.54 (E/B)

Sound pressure level (night mode) (3) dB(A) 52 (50) 52 (50) 55 (53) 57 (55) 58 (56) 59 (56)
Airflow in heat m³/h 3720 4080 4800 7620 8040 9780
Power supply 3N~400 V 50 Hz 3N~400 V 50 Hz 3N~400 V 50 Hz 3N~400 V 50 Hz 3N~400 V 50 Hz 3N~400 V 50 Hz
Pipe diameter (Liq - Gas) inches 3/8 - 5/8 3/8 - 5/8 3/8 - 5/8 3/8 - 1 1/2 - 1 1/2 - 1
Maximum length m 70 75 75 100 100 100
Maximum height 30/20 30/20 30/20 30/20 30/20 30/20
Initial refrigerant charge kg(m) /
3.2 (30) - 6.68 3.2 (30) - 6.68 3.2 (30) - 6.68 5.7 (30) - 11.9 6.2 (30) - 12.95 6.7 (30) - 13.99
(maximum length of pipes) GWP eq Ton
Additional refrigerant charge g/m 40 60 60 it must be calculated it must be calculated it must be calculated
Refrigerant R410A
Compressor SCROLL DC INVERTER

RAS - 4H(V)NC1E 79 kg RAS - 8HNCE 136 kg

RAS - 3HVNC1 44 kg RAS-5~6H(V)NC1E 89 kg RAS - 10HNCE 138 kg RAS - 12HNC 168 kg

300 mm
600 mm

370 mm
1650 mm
1380 mm
1140 mm

370 mm
390 mm

792 mm

950 mm
Side Flow VRF

950 mm 1100 mm

(1) The nominal cooling and heating capacity is the combined capacity of the RAS system and is based on EN14511
- Cooling: Indoor temperature 27°C DB; outdoor temperature 35°C DB.
- Heating: Indoor temperature 20°C DB; outdoor temperature 7°C DB, 6°C WB. Pipe length: 7.5 m
(2) SEER and SCOP conform to the EN 14825 regulation.
The SEER, SCOP, EER and COP are specified on the outdoor unit in combination with the indoor unit mentioned.
To create the energy label visit our COP and EER data are specified for RCI-FSN4 indoor unit combination.
website www.hitachiaircon.es and use (3) The sound pressure level has been measured in an anechoic camera at 1.5 m from ground level and 1 m from the front of the unit (Units
our Hitachi ErP AcTive Tool application. operating at their nominal supply voltage).
ENERGY
CLASS

UTOPIA IVX COMFORT
RAS - 3 ~ 6H(V)NC1E

Standard Capacities
in cooling and heating

Since January 1, 2015, the European Union‘s Eco-design ErP


regulations affect air conditioning units of less than 12 kW
(ErP.Tier 2 Directive). Therefore, the SEER and SCOP seasonal
yields must be shown in these units, which provide a more
accurate estimate of the actual performance of the product
during the period in use.

COMBINATIONS COOLING HEATING


P DESIGN (35ºC) P DESIGN (-10ºC)
OUTDOOR UNIT INDOOR UNIT SEER ENERGY CLASS SCOP ENERGY CLASS
KW KW
RCI-3,0FSN4 6.00 A+ 7.10 4.21 A+ 5.60
RPC-3,0FSN3 5.29 A 7.10 4.13 A+ 5.60
RAS-3HVNC1 RPC-3,0FSN3E 4.68 B 7.10 3.80 A 5.60
RPI-3,0FSN4E 4.97 B 7.10 3.80 A 5.60
RPK-3,0FSN3M 5.35 A 7.10 3.80 A 5.60
RCI-4.0FSN4 6.57 A ++ 10.00 4.47 A+ 8.70
RPC-4.0FSN3 5.02 B 10.00 3.90 A 8.70
RAS-4HVNC1E RPC-4.0FSN3E 4.61 B 10.00 3.80 A 7.40
RPI-4.0FSN4E 5.38 A 10.00 4.01 A+ 8.70
RPK-4.0FSN3M 5.56 A 10.00 3.83 A 7.40
RCI-4.0FSN4 6.41 A ++ 10.00 4.47 A+ 8.70
RPC-4.0FSN3 4.93 B 10.00 3.9 A 8.70
RAS-4HNC1E RPC-4.0FSN3E 4.53 C 10.00 3.8 A 7.40
RPI-4.0FSN4E 5.27 A 10.00 4.01 A+ 8.70
RPK-4.0FSN3M 5.45 A 10.00 3.83 A 7.40
MONO
COMBINATIONS

MONO COMBINATIONS

1x1 UTOPIA IVX COMFORT 1x1 UTOPIA IVX COMFORT


Wall mounted Duct

SET NAME INDOOR UNIT OUTDOOR UNIT SET NAME INDOOR UNIT OUTDOOR UNIT
Utopia RPK 3 IVX.V.3M RPK-3.0FSN3M RAS - 3HVNC1 Utopia RPI 3 IVX.V.C1 RPI - 3.0FSN4E RAS - 3HVNC1
Utopia RPK 4 IVX.V.3M RPK-4.0FSN3M RAS - 4HVNC1E Utopia RPI 4 IVX.V.C1E RPI - 4.0FSN4E RAS - 4HVNC1E
Utopia RPK 4 IVX.3M RPK-4.0FSN3M RAS - 4HNC1E Utopia RPI 4 IVX.C1E RPI - 4.0FSN4E RAS - 4HNC1E
Utopia RPI 5 IVX.V.C1E RPI - 5.0FSN4E RAS - 5HVNC1E
Utopia RPI 5 IVX.C1E RPI - 5.0FSN4E RAS - 5HNC1E
Utopia RPI 6 IVX.V.C1E RPI - 6.0FSN4E RAS - 6HVNC1E
Utopia RPI 6 IVX.C1E RPI - 6.0FSN4E RAS - 6HNC1E
Utopia RPI 5 IVX.V.C1E RPI - 5.0FSN4E RAS - 5HVNC1E
Utopia RPI 5 IVX.4E RPI - 5.0FSN4E RAS - 5HNC1E
Utopia RPI 6 IVX.V.4E RPI - 6.0FSN4E RAS - 6HVNC1E
Utopia RPI 6 IVX.4E RPI - 6.0FSN4E RAS - 6HNC1E

1x1 UTOPIA IVX COMFORT Utopia RPI 8 IVX.CE


Utopia RPI 10 IVX.CE
RPI - 8.0FSN3E
RPI - 10.0FSN3E
RAS - 8HNCE
RAS - 10HNCE
Ceiling

9
SET NAME INDOOR UNIT OUTDOOR UNIT
Utopia RPC 3 IVX.V.C1 RPC-3.0FSN3E RAS - 3HVNC1
Utopia RPC 4 IVX.V.C1E RPC-4.0FSN3E RAS - 4HVNC1E 1x1 UTOPIA IVX COMFORT
Utopia RPC 4 IVX.C1E RPC-4.0FSN3E RAS - 4HNC1E
4-Way Cassette
Utopia RPC 5 IVX.V.C1E RPC-5.0FSN3E RAS - 5HVNC1E
Utopia RPC 5 IVX.C1E RPC-5.0FSN3E RAS - 5HNC1E
Utopia RPC 6 IVX.V.C1E RPC-6.0FSN3E RAS - 6HVNC1E SET NAME INDOOR UNIT OUTDOOR UNIT PANEL
Utopia RPC 6 IVX.C1E RPC-6.0FSN3E RAS - 6HNC1E Utopia RCI 3 IVX.V.C1 RCI - 3.0FSN4 RAS - 3HVNC1 P N23NA2
Utopia RPC 3 IVX.V.3 RPC-3.0FSN3 RAS - 3HVNC1 Utopia RCI 4 IVX.V.C1E RCI - 4.0FSN4 RAS - 4HVNC1E P N23NA2
Utopia RPC 4 IVX.V.3 RPC-4.0FSN3 RAS - 4HVNC1E Utopia RCI 4 IVX.C1E RCI - 4.0FSN4 RAS - 4HNC1E P N23NA2
Utopia RPC 4 IVX.3 RPC-4.0FSN3 RAS - 4HNC1E Utopia RCI 5 IVX.V.C1E RCI - 5.0FSN4 RAS - 5HVNC1E P N23NA2
Utopia RPC 5 IVX.V.C1E RPC-5.0FSN3 RAS - 5HVNC1E Utopia RCI 5 IVX.C1E RCI - 5.0FSN4 RAS - 5HNC1E P N23NA2
Utopia RPC 5 IVX.3 RPC-5.0FSN3 RAS - 5HNC1E Utopia RCI 6 IVX.V.C1E RCI - 6.0FSN4 RAS - 6HVNC1E P N23NA2
Utopia RPC 6 IVX.V.3 RPC-6.0FSN3 RAS - 6HVNC1E Utopia RCI 6 IVX.C1E RCI - 6.0FSN4 RAS - 6HNC1E P N23NA2
Utopia RPC 6 IVX.3 RPC-6.0FSN3 RAS - 6HNC1E Utopia RCI 3 IVX.V.C1.4 RCI - 3.0FSN4 RAS - 3HVNC1E P N23NA2

Standard Control
Side Flow VRF

Wired Multifunction Control


PC-ARFPE
COMBINATIONS
OUTDOOR

UTOPIA IVX COMFORT
UNIT
RAS - 3 ~ 6H(V)NC1E

RASC-3H(V)NC1 RAS - 4~6H(V)NC1E RAS-8~12HNC(E)

90 - 110% 90 - 115% 90 - 115%

Capacity Index in relation to combinations

OUTDOOR UNIT MODEL


COMBINATIONS
RAS - 3HVNC1 RAS - 4 H(V)NC1E RAS - 5H(V)NC1E RAS - 6 H(V)NC1E
Maximum number of connected indoor units 2 4

Ratio of connected indoor units % 90~110% (1 unit) 90~115% (≤ 2 units)


(number of indoor units connected) 90~100% (2 units) 90~100% (3 or 4 units)
Connectable indoor unit minimum capacity (HP) 0.8 HP

OUTDOOR UNIT MODEL


COMBINATIONS
RAS - 8HNCE RAS - 10HNCE RAS - 12HNCE
Maximum number of connected indoor units 4

Ratio of connected indoor units % 90~115%


(number of indoor units connected) 90~115%
Connectable indoor unit minimum capacity (HP) 1.8 HP
Capacity Index in relation to combinations
All pipes behind the bifurcation pipes (B,C,D,E,F or G) must
be balanced, and the differences between these Sections
cannot be higher than indicated in the following tables.

TWIN Combination TRI Combination


RAS-3~5H(V)NC1E RAS-3~5H(V)NC1E
S-8~12HNC(E) RAS-8~12HNC(E)

H L L
A H

B C D
B C

L = A+ the longest of B and C


L = A + the longest of B, C and D

Mono Combination Combination QUADRI


RAS-3~5H(V)NC1E RAS-4~12H(V)NC1(E) L
RAS-10HNCE
A C

H
L
F G

11
D E

NOTE: L and H are length and height, respectively.


In TWIN, TRI, QUADRI combinations, the length is the distance between the outdoor unit and the farthest indoor unit.

Maximum length of standard installation pipe


RAS - 3HVNC1 RAS - 4 H(V)NC1E RAS - 5H(V)NC1E RAS - 6 H(V)NC1E RAS - 8HNCE RAS - 10HNCE RAS - 12HNCE
Maximum pipe length Real pipe length 50 70 75 100
between the outdoor unit
and the farthest indoor
Equivalent pipe length 70 90 95 125
unit.
TWIN (A + B + C) 60 80 85 100 115
Total maximum length TRI (A + B + C + D) - 90 95 100 130
QUADRI (A + B + C + D + E + F + G) - 90 95 100 145
Maximum pipe length after TWIN and TRI (B, C, D) m 10 15
the first derivation. QUADRI (B +D, B + E, C + F, C + G) - 10 15
Main pipe length A › B,C,D,E,F,G
Maximum height difference: Outdoor unit higher than indoor
30/20
unit / Indoor unit higher than outdoor unit
Maximum height difference between the indoor units 3
Maximum height difference between main branch pipe and indoor
3
unit (TWIN, TRI, QUDRI) and between QUADRI branch pipes
Difference of lengths between sections
(B-C) (TWIN and TRI)
Side Flow VRF

(B-D) (TRI)
(C-D) (TRI)
(C+G)-(C+F) (QUADRI)
m ≤8
(B+E)-(B+D) (QUADRI)
(C+G)-(B+E) (QUADRI)
(C+G)-(B+D) (QUADRI)
(C+F)-(B+E) (QUADRI)
(C+F)-(B+D) (QUADRI)
STANDARD REFRIGERANT
DISTRIBUTION

UTOPIA IVX COMFORT
RAS - 3 ~ 6H(V)NC1E

Pipe length specifications


Select pipe connection sizes with the following instructions:
Between the outdoor unit and the bifurcation pipe: Select the same size for connecting the pipes as for the outdoor unit.
Between the bifurcation pipe and the indoor unit: Select the same size for connecting the pipes as for the indoor unit.

PERFORMANCE LIQUID Ø 6.35 Ø 9.52 Ø 12.70 Ø 15.88


CAPACITY GAS Ø 9.52 Ø 12.70 Ø 15.88 Ø 19.05 Ø 12.70 Ø 15.88 Ø 19.05 Ø 22.20 Ø 25.40 Ø 15.88 Ø 19.05 Ø 22.20 Ø 25.40 Ø 28.58 Ø 22.20 Ø 25.40 Ø 28.60
RAS - 3HVNC1 - 30 (1) (2) 30 (2) - 30 (1) 50 - - - - - - - - - - -
RAS - 4 H(V)NC1E - - 5 (2) 5 (2) 40 (1) 70 50 (4) - - 30 (3) 30 (3) (4) - - - - - -
RAS - 5~6H(V)NC1E - - 5 (2)
5 (2)
40 (1)
75 50 (4)
- - 30 (3)
30 (3) (4)
- - - - - -
RAS - 8HNCE - - - - - - 50 (1) (4) 50 (1) 70 (5) (6) - 50 (1) (3) (4) 50 (1) (3) 100 - 50 (1) (3) 50 (3) -
RAS - 10~12HNC(E) - - - - - - - - - - - 50 (1)
100 50 50 (1) (3)
50 (3)
50 (3)

(1) Reducing the size of the gas pipe will reduce the cooling capacity as there will be a greater loss of pressure in the gas pipe and the operating margin will be reduced.
(2) Reducing the size of the liquid pipe will reduce the operating range due to the ratio of the indoor unit to the capacity of the expansion valve.
(3) Increasing the size of the liquid pipe will require an additional refrigerant charge.
(4) When using gas pipes of Ø19.05, set pin 4 of the DSW2 on the outdoor unit's PCB to the ON position.
(5) If the pipe length is more than 70 m for 8 HP, use a liquid pipe of Ø12.70.
In case of exceeding the recommended number of 8 HP connected indoor units (more than five units) use a Ø12.70 liquid pipe.

Standard specifications.

Connection size of the external unit pipes and the multikit


PIPE SIZE MULTIKIT
OUTDOOR UNIT
LIQUID GAS TWIN TRI QUADRI
RAS - 3HVNC1 3/8" 5/8" E-102SN4 -
RAS - 4 H(V)NC1E 3/8" 5/8"
E-102SN4 E-102SN4
RAS - 5H(V)NC1E 3/8" 5/8" E-102SN4
MH-84AN1 (2)
RAS - 6 H(V)NC1E Inches 3/8" 5/8"
RAS - 8HNCE 3/8" (1) 1"
E-162SN4 E-162SN4
RAS - 10HNCE 1/2" 1" E-162SN4
MH-84AN1 (2) MH-84AN1 (2)
RAS - 12HNCE 1/2" 1"

(1) If the pipe length (A+B or A+C or A+D) exceeds 70 m in 8 HP units, use a Ø12.70 liquid pipe.
(2) If you use the MH84AN1 multi-kit (TRI combination figure) it is not necessary to use multikit 2.

Fisherman's Museum, Bermeo.


Utopia Comfort
Refrigerant distribution in line
(only IVX COMFORT series) RAS-4~12H(V)NC1(E)
This figure shows examples of 4 indoor units combined with an outdoor unit.
Refrigerant pipes are shown as a single line in diagrams.
However, the liquid and gas pipes are necessary in the installation.

A B

L3 L3 L3 L3 L2

C
L4

L1
D

ELEMENT RAS - 4H(V)NC1E RAS - 5H(V)NC1E RAS - 6H(V)NC1E RAS - 8HNCE RAS - 10HNCE RAS - 12HNCE

Maximum pipe length between Real length (L1) 70 75 100

13
the outdoor unit and the farthest
indoor unit. Equivalent length 90 95 125

Maximum length from the first branch pipe to each


20 25
indoor unit (L2)
Maximum pipe length from the branch pipe of the
10 15
indoor unit (L3)
Total pipe length L4 + (L3 1 + L3 2 + L3 3 …) 70 75 100 145
m
Maximum height difference between the outdoor
unit and the indoor unit / If the indoor unit is higher 30/20
than the indoor unit.
Maximum height difference between the indoor units 3
Maximum height difference:
Bifurcation / indoor pipes 3
Bifurcation / outdoor pipes

PIPE SIZE (C,D) (L4)MM MULTI-KIT MODEL MULTI-KIT MODEL


OUTDOOR UNIT
LIQUID GAS A B

RAS - 3~6H(V)NC1E 3/8" 5/8" E-102SN4


RAS-8HNCE Inches 3/8" (1) 1"
E-162SN4
RAS-10~12HNC(E) 1/2" 1"

(1) If the pipe length from the outside to the farthest indoor unit is more than 70 m in 8 HP units, use a liquid pipe of Ø12.70

Size of the connecting pipes between the bifurcation pipe and the indoor unit
Side Flow VRF

PIPE SIZE (Ø MM)


TOTAL CAPACITY OF THE INDOOR UNIT
LIQUID GAS
≤ 1.50 HP 1/4" 1/2"
1.80~2.00 HP Inches 1/4" 5/8"
≥2.30 HP 3/8" 5/8"

- Combination pipe sizes: TWIN (B,C), TRI (B,C,D) and QUADRI (D,E,F and G).
-Except in 8 and 10 HP units where connection is not possible.
MAXIMUM COOLING

8
UP TO
DISTANCE EQUIVALENT
UNITS
INDEPENDENT
TO UP TO 125 M

S
OL
TR
N
O
C
IN D E NT
PENDE

AIR CONDITIONING FOR 8


DIFFERENT SPACES WITH COMPLIES WITH
INDEPENDENT CONTROL EUROPEAN
REGULATIONS LOT.11
AND THE ERP.TIER 2
DIRECTIVE

SMALLER MINI VRF


WITH 2 TO 3 HP MODELS,
WITH A SUPERIOR HEIGHT
UTOPIA
IVX

PREMIUM
UTOPIA IVX PREMIUM

The most competitive air-conditioning


solution for all types of business. ▶ Cools up to 8 different
Maximum comfort ambiance so that customers feel spaces
comfortable and enjoy their experience.
▶ Independent control
SEER of 7.88 (A++) and SCOP of 4.77 (A++). ▶ Capacity index between
50% and 120%
Connectable indoor unit minimum
capacity 0.8 HP. ▶ Compatible with all
Hitachi control and
Decrease in defrost time and increase in management systems
heating time.

INTELLIGENT DEFROST CONTROL


HEATING OPERATION WILL BE CONTINUOUSLY
AVAILABLE FOR MORE TIME

REAL DEFROST TIME LESS


THAN ESTIMATED

15
HEATING OPERATION DEFROST

ESTIMATED TIME ESTIMATED DEFROST


OPERATION TIME
THE NEXT TIME:

HEATING OPERATION DEFROST

ESTIMATION BASED ON
EXTENDED TIME
PREVIOUS TIME

The 4-way valve does not require electricity


consumption to maintain operation in heating mode,
and can save up to 43%.
Side Flow VRF
OUTDOOR UNIT
MULTI-INVERTER

UTOPIA IVX PREMIUM
RAS-2~6H(V)NP1E / RAS-8~10HNPE

Characteristics

Smallest Mini VRF on the market DC Inverter Compressor


It is the perfect option for air conditioning small and Save on the electric bill for optimization at partial loads of
medium-sized businesses, with highly demanding up to 50%. Increased performance at low speed thanks to
requirements. It has higher height and does not overwhelm the transmission mechanism and engine refinement.
the facilities with its size.
Decrease in frost generation
Flexibility It optimizes operation in heating mode to maintain the
Compatible with System Free indoor units that are suitable temperature in each room.
managed through all individual and centralized control
Air-condition up to 8 different spaces
systems, with option to H - Link II and CSNET WEB/
Independent management of spaces, each with its own
MANAGER.
control.
Optional DX-KIT
Intended for the integration of air curtains and air
treatment units when required.

OFF

ON 20º

ON 22º

ON 18º

OFF

ON 18º

ON 22º
ON 18º
Guaranteed performance

8
+15 +46
UP TO
UNITS
R&D+i
INTERFACE INDEPENDENT
BY
-20 -15 H-LINK II

S
OL
TR
N
O
C
N T
IN D E
PENDE

UTOPIA IVX PREMIUM SINGLE PHASE


Outdoor Units RAS-2HVNP1 RAS-2.5 HVNP1 RAS-3HVNP1E RAS-4HVNP1E RAS-5HVNP1E RAS-6HVNP1E
Maximum number of connected units 2 3 5 6
Nominal power absorbed Cooling 5.00 (2.20~5.60) 5.60 (2.20~6.30) 7.10 (3.20~8.00) 10.00 (4.50~11.20) 12.50 (5.70~14.00) 14.00 (6.00~16.00)
kW
(min-max)(1) Heating 5.60 (2.20~7.10) 6.30 (2.20~8.00) 8.00 (3.50~10.60) 11.20 (5.00~14.00) 14.00 (5.00~18.00) 16.00 (5.00~20.00)
Cooling 1.17 1.20 1.46 1.99 3.11 3.94
Absorbed nominal power kW
Heating 1.13 1.30 1.52 2.02 2.91 3.61
More information More information More information More information
EER - COP (2)
see next page see next page see next page see next page
3.81 - 4.55 (A/B) 3.41 - 4.23 (A/A)

Sound pressure level (night mode)(3) dB(A) 44(42) 45(43) 46(42) 47(43) 48(44) 48(45)
Airflow m³/h 2436 2436 2700 4800 5400 6000
Power supply 1~230 V 50H 1~230 V 50H 1~230 V 50H 1~230 V 50H 1~230 V 50H 1~230 V 50H
Pipe diameter (Liq - Gas) inches 1/4 - 1/2 1/4 - 1/2 3/8 - 5/8 3/8 - 5/8 3/8 - 5/8 3/8 - 5/8
Maximum length 50 50 50 75 75 75
m
Maximum height 30/20 30/20 30/20 30/20 30/20 30/20
Refrigerant charge (Maximum length of kg(m) /
1.6 (30) - 3.34 1.6 (30) - 3.34 2.3 (30) - 4.8 4.1 (30) - 8.56 4.2 (30) - 8.77 4.2 (30) - 8.77
pipes without charge) GWP eq Ton

Additional refrigerant charge g/m 30 30 40 60 60 60


Independent control YES YES YES YES YES YES
Refrigerant R410A R410A R410A R410A R410A R410A
Compressor SCROLL SCROLL Rotary SCROLL SCROLL SCROLL

UTOPIA IVX PREMIUM THREE-PHASE


Outdoor Units RAS-4HNP1E RAS-5HNP1E RAS-6HNP1E RAS-8HNPE RAS-10HNPE RAS-12HNP
Possible Combinations 5 6 6 8 8 8
Cooling 10.00 (4.50~11.20) 12.50 (5.70~14.00) 14.00 (6.00~16.00) 20.00 (8.00~22.40) 25.00 (10.00~28.00) 30.00 (11.20~33.50)
Nominal power (1)
Heating kW 11.20 (5.00~14.00) 14.00 (5.00~18.00) 16.00 (5.00~20.00) 22.40 (6.30~28.00) 28.00 (8.00~35.00) 33.50 (9.00~37.50)
Cooling 1.99 3.11 3.94 5.36 7.88 11.05
Absorbed nominal power
Heating 2.02 2.91 3.61 5.06 7.03 8.96

17
EER - COP(2) 4.68 - 5.16 (A/A) 3.81 - 4.55 (A/A) 3.41 - 4.23 (A/A) 3.56 - 4.21 (A/A) 3.07 - 3.84 (B/A) 2.65 - 3.64 (D/A)
Sound pressure level (night mode) (3) dB(A) 47 (43) 48 (44) 48 (45) 57 (55) 58 (56) 59 (57)
Airflow in heat m³/h 4800 5400 6000 7620 8040 9780
Power supply 3 N~400 V 50 Hz 3 N~400 V 50 Hz 3 N~400 V 50 Hz 3 N~400 V 50 Hz 3 N~400 V 50 Hz 3 N~400 V 50 Hz
Pipe diameter (Liq - Gas) inches 3/8 - 5/8 3/8 - 5/8 3/8 - 5/8 3/8 - 1 1/2 - 1 1/2 - 1
Maximum length 75 75 75 it must be calculated it must be calculated it must be calculated
m
Maximum height 30/20 30/20 30/20 30/20 30/20 30/20
Initial refrigerant charge kg(m) /
4.1 (30) - 8.56 4.2 (30) - 8.77 4.2 (30) - 8.77 5.7 (30) - 11.9 6.2 (30) - 12.95 6.7 (30) - 13.99
(maximum length of pipes) GWP eq Ton
Additional refrigerant charge g/m 60 60 60 100 100 100
YES YES YES YES YES YES
Refrigerant R410A R410A R410A R410A R410A R410A
Compressor SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL

RAS-8HNPE 136 kg

RAS-4~6H(V)NP1E 103 kg
RAS-12HNP 168 kg
RAS-10HNPE 138 kg

RAS-2~2.5HVNP1 43 kg RAS - 3HVNP1E 66 kg


390 mm
1650 mm
1380 mm

300 mm 370 mm
800 mm
600 mm

370 mm

792 mm 950 mm 950 mm 1100 mm


Side Flow VRF

* For systems with two indoor units, the additional refrigerant charge required is 24 g/m.
(1) The nominal cooling and heating capacity is the combined capacity of the RAS system and is based on EN14511
- Cooling: Indoor temperature 27°C DB; outdoor temperature 35°C DB.
- Heating: Indoor temperature 20°C DB; outdoor temperature 7°C DB, 6°C WB. Pipe length: 7.5 m
(2) SEER and SCOP conform to the EN 14825 regulation.
The SEER, SCOP, EER and COP are specified on the outdoor unit in combination with the indoor unit mentioned.
To create the energy label visit our COP and EER data are specified for RCI-FSN4 indoor unit combination.
website www.hitachiaircon.es and use (3) The sound pressure level has been measured in an anechoic camera at 1.5 m from ground level and 1 m from the front of the unit (Units
our Hitachi ErP AcTive Tool application. operating at their nominal supply voltage).
ENERGY
CLASS

UTOPIA IVX PREMIUM
RAS-2~6H(V)NP1E / RAS-8~10HNPE

Seasonal performance in cooling and heating

COMBINATIONS COOLING HEATING


P DESIGN (35ºC) P DESIGN (-10ºC)
OUTDOOR UNIT INDOOR UNIT SEER ENERGY CLASS SCOP ENERGY CLASS
KW KW
RCI-2.0FSN4 6.49 A++ 5.00 4.67 A++ 5.00
RPC-2.0FSN3 5.63 A+ 5.00 4.44 A+ 5.00
RAS-2HVNP1 RPC-2.0FSN3E 5.05 B 5.00 3.8 A 5.00
RPI-2.0FSN4E 5.6 A+ 5.00 4.01 A+ 5.00
RPK-2.0FSN3M 5.47 A 5.00 4.01 A+ 5.00
RCI-2.5FSN4 6.05 A+ 5.60 4.77 A++ 5.20
RPC-2.5FSN3 5.49 A 5.60 4.49 A+ 5.20
RAS-2,5HVNP1 RPC-2.5FSN3E 4.66 B 5.60 3.8 A 5.20
RPI-2.5FSN4E 5.51 A 5.60 4.33 A+ 5.20
RPK-2.5FSN3M 5.24 A 5.60 4.14 A+ 5.20
RCI-3.0FSN4 7.42 A++ 7.10 4.37 A+ 6.40
RPC-3.0FSN3 5.87 A+ 7.10 4.00 A+ 6.00
RAS-3HVNP1E RPC-3.0FSN3E 5.33 A 7.10 3.80 A 6.00
RPI-3.0FSN4E 6.05 A+ 7.10 4.00 A+ 6.00
RPK-3.0FSN3M 6.4 A++ 7.10 3.91 A 6.00
RCI-4.0FSN4 7.88 A++ 10.00 4.68 A++ 11.50
RPC-4.0FSN4 6.53 A++ 10.00 4.23 A+ 11.50
RAS-4HVNP1E RPC-4.0FSN3E 5.92 A+ 10.00 3.81 A 11.20
RPI-4.0FSN4E 7.21 A++ 10.00 4.23 A+ 11.50
RPK-4.0FSN3M 6.81 A++ 10.00 3.81 A 9.00
RCI-4.0FSN4 7.66 A++ 10.00 4.68 A++ 11.50
RPC-4.0FSN4 6.38 A++ 10.00 4.23 A+ 11.50
RAS-4HNP1E RPC-4.0FSN3E 5.8 A+ 10.00 3.81 A 11.20
RPI-4.0FSN4E 6.3 A++ 10.00 4.23 A+ 11.50
RPK-4.0FSN3M 6.64 A++ 10.00 3.81 A 9.00
MONO
COMBINATIONS

MONO COMBINATIONS

1x1 UTOPIA IVX PREMIUM 1x1 UTOPIA IVX PREMIUM


Wall mounted Ceiling
Set name Indoor unit Outdoor unit Set name Indoor unit Outdoor unit
UTP.RPK2.IVX.V.PM1.3M RPK-2.0FSN3M RAS - 2HVNP1 UTP.RPC3.IVX.V.PM1.3E RPC-3.0FSN3E RAS - 3HVNP1E
UTP.RPK2,5.IVX.V.PM1.3M RPK-2.5FSN3M RAS - 2.5HVNP1 UTP.RPC4.IVX.V.PM1.3E RPC-4.0FSN3E RAS - 4HVNP1E
UTP.RPK3.IVX.V.PM1.3M RPK-3.0FSN3M RAS - 3HVNP1E UTP.RPC4.IVX.PM1.3E RPC-4.0FSN3E RAS - 4HNP1E
UTP.RPK4.IVX.V.PM1.3M RPK-4.0FSN3M RAS - 4HVNP1E UTP.RPC5.IVX.V.PM1.3E RPC-5.0FSN3E RAS - 5HVNP1E
UTP.RPK4.IVX.PM1.3M RPK-4.0FSN3M RAS - 4HNP1E UTP.RPC5.IVX.PM1.3E RPC-5.0FSN3E RAS - 5HNP1E
UTP.RPC6.IVX.V.PM1.3E RPC-6.0FSN3E RAS - 6HVNP1E
UTP.RPC6.IVX.PM1.3E RPC-6.0FSN3E RAS - 6HNP1E
UTP.RPC2.IVX.V.PM1.3 RPC-2.0FSN3 RAS - 2HVNP1
1x1 UTOPIA IVX PREMIUM UTP.RPC2,5.IVX.V.PM1.3 RPC-2.5FSN3 RAS - 2.5HVNP1

Duct UTP.RPC3.IVX.V.PM1.3 RPC-3.0FSN3 RAS - 3HVNP1E


UTP.RPC4.IVX.V.PM1.3 RPC-4.0FSN3 RAS - 4HVNP1E
Set name Indoor unit Outdoor unit UTP.RPC4.IVX.PM1.3 RPC-4.0FSN3 RAS - 4HNP1E
UTP.RPI2.IVX.V.PM1.4E RPI - 2.0FSN4E RAS - 2HVNP1 UTP.RPC5.IVX.V.PM1.3 RPC-5.0FSN3 RAS - 5HVNP1E
UTP.RPI2,5.IVX.V.PM1.4E RPI - 2.5FSN4E RAS - 2.5HVNP1 UTP.RPC5.IVX.PM1.3 RPC-5.0FSN3 RAS - 5HNP1E
UTP.RPI3.IVX.V.PM1.4E RPI - 3.0FSN4E RAS - 3HVNP1E UTP.RPC6.IVX.V.PM1.3 RPC-6.0FSN3 RAS - 6HVNP1E
UTP.RPI4.IVX.V.PM1.4E RPI - 4.0FSN4E RAS - 4HVNP1E UTP.RPC6.IVX.PM1.3

19
RPC-6.0FSN3 RAS - 6HNP1E
UTP.RPI4.IVX.PM1.4E RPI - 4.0FSN4E RAS - 4HNP1E
UTP.RPI5.IVX.V.PM1.4E RPI - 5.0FSN4E RAS - 5HVNP1E
UTP.RPI5.IVX.PM1.4E RPI - 5.0FSN4E RAS - 5HNP1E
UTP.RPI6.IVX.PM1.V.4E RPI - 6.0FSN4E RAS - 6HVNP1E 1x1 UTOPIA IVX PREMIUM
UTP.RPI6.IVX.PM1.4E RPI - 6.0FSN4E RAS - 6HNP1E 2-Way Cassette
UTP.RPI8.IVX.PM1.3E RPI - 8.0FSN3E RAS - 8HNPE
Set name Indoor unit Outdoor unit Panel
UTP.RPI10.IVX.PM1.3E RPI - 10.0FSN3E RAS - 10HNPE
UTP.RCD2.IVX.V.PM1.2 RCD-2.0FSN3 RAS - 2HVNP1 P-AP90DNA
UTP.RCD2,5.IVX.V.PM1.2 RCD-2.5FSN3 RAS - 2.5HVNP1 P-AP90DNA
UTP.RCD3.IVX.V.PM1.2 RCD-3.0FSN3 RAS - 3HVNP1E P-AP90DNA
UTP.RCD4.IVX.V.PM1.2 RCD-4.0FSN3 RAS - 4HVNP1E P-AP160DNA
UTP.RCD4.IVX.PM1.2 RCD-4.0FSN3 RAS - 4HNP1E P-AP160DNA
UTP.RCD5.IVX.V.PM1.2 RCD-5.0FSN3 RAS - 5HVNP1E P-AP160DNA
UTP.RCD5.IVX.PM1.2 RCD-5.0FSN3 RAS - 5HNP1E P-AP160DNA

1x1 UTOPIA IVX PREMIUM


4-Way Cassette
Set name Indoor unit Outdoor unit Panel
UTP.RCI2.IVX.V.PM1.4 RCI - 2.0FSN4 RAS - 2HVNP1 P N23NA2
UTP.RCI2,5.IVX.V.PM1.4 RCI - 2.5FSN4 RAS - 2.5HVNP1 P N23NA2
Standard Control UTP.RCI3.IVX.V.PM1.4 RCI - 3.0FSN4 RAS - 3HVNP1E P N23NA2
UTP.RCI4.IVX.V.PM1.4 RCI - 4.0FSN4 RAS - 4HVNP1E P N23NA2
Side Flow VRF

UTP.RCI4.IVX.PM1.4 RCI - 4.0FSN4 RAS - 4HNP1E P N23NA2


Wired Multifunction Control UTP.RCI5.IVX.V.PM1.4 RCI - 5.0FSN4 RAS - 5HVNP1E P N23NA2
PC-ARFPE UTP.RCI5.IVX.PM1.4 RCI - 5.0FSN4 RAS - 5HNP1E P N23NA2
UTP.RCI6.IVX.V.PM1.4 RCI - 6.0FSN4 RAS - 6HVNP1E P N23NA2
UTP.RCI6.IVX.PM1.4 RCI - 6.0FSN4 RAS - 6HNP1E P N23NA2
COMBINATIONS
OUTDOOR

UTOPIA IVX PREMIUM
UNIT
COMBINATIONS | RAS-2~6H(V)NP1E / RAS-8~10HNPE

RAS-2HVNP1 RAS-3HVNP1E RAS-4H(V)NP1E RAS-5H(V)NP1 RAS - 8HNPE


RAS-2.5 HVNP RAS-6H(V)NP1E RAS - 10HNPE
RAS - 12HNP

90 - 110% 50 - 120%
Capacity Index in relation to combinations

OUTDOOR UNIT MODEL


COMBINATIONS
RAS-2HVNP1(2) RAS-2.5 HVNP(3) RAS-3HVNP1E RAS-4H(V)NP1E RAS-5H(V)NP1E RAS-6H(V)NP1E
Maximum number of connected indoor units 2 3 5 6

Ratio of connected indoor units % 90~110% (1 unit) 50~120% (≤ 2units) 50~120% (≤ 4 units)
(number of indoor units connected) 90~100% (2 units)(1) 50~100% (3 units) 50~100% (5 units)(1) 50~100% (5 or 6 units)(1)
Connectable indoor unit minimum capacity (HP) 0.8

OUTDOOR UNIT MODEL


COMBINATIONS
RAS - 8HNPE RAS - 10HNPE RAS - 12HNP
Maximum number of connected indoor units 8

Ratio of connected indoor units % 50~120% (≤ 4 units)


(number of indoor units connected) 50~100% (5, 6, 7 or 8 units)
Connectable indoor unit minimum capacity (HP) 0.8

(1) Follow Table 1 (see instructions) to optimize indoor unit balance.


(2) When installing RCI-FSN4 indoor unit, only the 1x1 combination is allowed.
(3) When installing certain units and RCI-FSN4 is present, the minimum allowed capacity for these series is 1.5 HP.

21
Capacity Index in relation to combinations

MULTI-KIT
OUTDOOR UNIT
TWIN TRI QUADRI
RAS-2HVNP1 - -
RAS-2.5 HVNP1 - -
RAS-3HVNP1E E-102SN4 -
E-102SN4
RAS-4H(V)NP1E
E-102SN4
RAS-5H(V)NP1E E-102SN4
MH-84AN1(2)
RAS-6H(V)NP1E
RAS-8HNPE
E-162SN4 E-162SN4
RAS-10HNPE E-162SN4
MH-84AN1(2) MH-84AN1(2)
RAS-12HNPE

(1) If the pipe length (A+B or A+C or A+D) exceeds 70 m in 8 HP units, use a Ø12.70 liquid pipe.
(2) If you use the MH84AN1 multi-kit (TRI combination figure) it is not necessary to use multikit 2.
Note: For in-line TRI combinations, the second branch pipe is E102SN4
Side Flow VRF
AIR CONDITIONING FOR
USE WITH AHU AND AIR THREE DIFFERENT
CURTAINS TYPES OF CONTROL:
AIR INLET, AIR OUTLET,
DUTY CYCLE

SMALLER MINI VRF


FROM 3 HP MODELS
DX-KIT SERIE 2
FEATURES

UTOPIA DX CONDENSING UNIT

The new RAS-XH (V) NP series (1) E is


optimized for use with the new DX-Kit series 2.

Precise power control and fast response


to variable operating parameters make it
suitable for use with air-conditioning units.
Compared to standard condensing units from
the HITACHI portfolio allows the connection COMPRESSOR
OWN
of heat exchangers with larger volumes and
hence with a larger heat transfer area.

Features and benefits


Possibility to control analog signal (0-10V, 0-5V, Sophisticated defrosting system -> Better user comfort
4-20mA) • Checking the number of defrosting condensing units at
Modular installation for multi-ring heat exchangers the same time:
• Possibility to connect up to 5 condensing units per AHU · 2-3 condensing units: max. 1 in the reverse cycle
unit (up to 125 kW) · 4-5 condensing units: max. 2 in the reverse cycle

23
• Group Control of Condensation Units (Master - Slave) • Top-down defrost logic for better defrosting
• Common air temperature sensors • Possibility to connect to larger volumetric exchangers
• Common controller to set operating parameters

Modular installation scheme for multi terminal exchangers


MASTER UNIT DX-KIT 2

Control
module
0-10V ...........

PC ARFPE Expansion
valve

Liquid Liquid temperature sensor


Gas
Gas temperature sensor

SLAVEUNIT DX-KIT 2

Control
module
Intake air AIR
temperature Outdoor air
sensor temperature
Expansion sensor
valve
Liquid temperature
Liquid sensor
Gas
Gas temperature sensor

SLAVEUNIT DX-KIT 2
Side Flow VRF

Control
module

Expansion
valve

Liquid Liquid temperature sensor


Gas
Gas temperature sensor
– The DX-KIT can also be combined with UTOPIA and Set Free
DX-KIT SERIE 2 Sigma series. For optimum performance we recommend using
it with Utopia DX dedicated series.

RECOMMENDED SOLUTION
APPLICATION UTOPIA DX
UTOPIA (NOT DX) SET FREE SIGMA (5)
RAS‑XH(V)NP(1)E
Combinability 1‑1 – Multi (6)
Control type Depending on output temperature – Depending on output temperature
AIR CURTAIN
Capacity range 2‑10 HP – 2‑10 HP
Accuracy of regulation ����� – ����� (1)

Combinability 1‑1 Modular Multi (6)

DUCTED UNIT Control type Depending on output temperature Depending on output temperature Depending on output temperature
(≤ 10% FRESH AIR) Capacity range 2‑10 HP 12‑50 HP (2) (3) 2‑10 HP
Accuracy of regulation ����� ����� ����� (1)

Combinability Individually or modular


Depending on output temperature
Control type
HVAC UNITS LOW PRECISION REGULATION or external signals LOW PRECISION REGULATION
Capacity range 4‑50 HP (3) (4)
Accuracy of regulation �����

(1) VRF system management focuses on cooling cycle states and output, not just on the supply air temperature.
(2) The power range is obtained by combining 3 HP to 10 HP outdoor unit models (RAS-XH (V) NP (1) E series).
(3) A group of condensing units for modular wiring must be composed of modules of the same size for proper power balance.
(4) The power range is obtained by combining 4 HP to 10 HP outdoor units (RAS-XH (V) NP (1) E series).
(5) Combination 1-1 with Set Free is not allowed
(6) Representation of DX-KITs between connected indoor units.

≤ 30% 30 ~ 100%
Total percentage of connected power to outdoor unit (%)
30 ~ 130% 50 ~ 100%

1~230V 50Hz

UTOPIA DX Outdoor Units RAS‑3XHVNP1E RAS‑4XHVNP1E RAS‑5XHVNP1E RAS‑6XHVNP1E

Nominal cooling capacity (min-max) kW 7.1 (3.2‑8.0) 10.0 (4.5‑11.2) 12.5 (5.7‑14.0) 14.0 (6.0‑16.0)


Nominal heating capacity (min-max) kW 8.0 (3.5‑10.6) 11.2 (5.0‑14.0) 14.0 (5.0‑18.0) 16.0 (5.0‑20.0)
EER 4.41 4.68 3.81 3.41
COP 4.88 5.16 4.55 4.23
Sound pressure level when cooling (night attenuation)
dB(A) 46 (42) / 48 47 (43) / 49 48 (44) / 50 48 (45) / 50
/ heating
Sound power level dB(A) 63 63 64 65
Air flow m3 / min 45 80 90 100
Dimensions mm 800x950x370 1380x950x370 1380x950x370 1380x950x370
Weight kg 66 103 103 103
Recommended circuit breaker A 20 32 32 32
Maximum current A 21.5 30.5 30.5 30.5
Operating cooling flow A 6.4 8.7 13.7 17.3
Operating heating current A 6.7 8.9 12.8 15.9
Section of power cable (according to EN 60335-1) Nbr. / mm² 3x 4.0 3x 6.0 3x 6.0 3x 6.0
The size of the communication cable between
Nbr. / mm² 2x 0.75 2x 0.75 2x 0.75 2x 0.75
the outdoor unit and the indoor unit
 Ø9.52 (3/8) / Ø9.52 (3/8) / Ø9.52 (3/8) / Ø9.52 (3/8) /
Piping diameter (liquid / gas) mm (inch)
Ø15.88 (5/8)  Ø15.88 (5/8)  Ø15.88 (5/8) Ø15.88 (5/8)
Minimum pipe length m 5 5 5 5
Maximum piping length without additional refrigerant
m 30 30 30 30
charge
Maximum pipe length (when refrigerant is added) m 50 75 75 75
Maximum height difference (outdoor unit – Heat
m 30 / 20 30 / 20 30 / 20 30 / 20
exchanger)
Refrigerant Refrigeration Factory - R410a kg - GWP eq Ton 2.3 - 4.8 4.1 - 8.56 4.2 - 8.77 4.2 - 8.77
Compressor type Rotary DC inverter Scroll DC inverter Scroll DC inverter Scroll DC inverter
Design parameters of the external heat exchanger in combination with UTOPIA DX condensing unit.

PERMITTED CAPACITY OF HEAT EXCHANGER INTERNAL HEAT EXCHANGER RECOMMENDED HEAT EXCHANGER
[kW] (1) VOLUME [dm³] (2) AIR FLOW [m³/min]
DX‑KIT OP. MODE MIN. NOM. MAX. MIN. MAX. MIN. MAX.
Cooling 4.0 5.0 5.6
EXV‑2.0E2 0.57 1.64 8.0 21.0
Heating 4.5 5.6 7.1
Cooling 4.8 6.0 6.3
EXV‑2.5E2 0.89 1.83 11.5 26.0
Heating 5.6 7.0 7.1
Cooling 5.7 7.1 8.0
EXV‑3.0E2 1.03 2.89 12.5 30.0
Heating 6.4 8.0 9.0
Cooling 8.0 10.0 11.2
EXV‑4.0E2 1.51 4.56 20.0 36.0
Heating 9.0 11.2 12.5
Cooling 10.0 12.5 14.0
EXV‑5.0E2 1.92 4.56 23.0 41.5
Heating 11.2 14.0 16.0
Cooling 11.2 14.0 16.0
EXV‑6.0E2 1.92 5.11 25.0 42.5
Heating 12.8 16.0 18.0
Cooling 16.0 20.0 22.4
EXV‑8.0E2 2.92 6.93 59.0 78.0
Heating 17.9 22.4 25.0
Cooling 20.0 25.0 28.0
EXV‑10.0E2 3.89 10.73 68.0 89.0
Heating 22.4 28.0 31.5

Cooling and heating performance is based on thermal conditions according to EN14511:


HEATING COOLING
DX‑interface HEX (Tin): 20 °C (DB) DX‑Interface HEX (Tin): 27 °C (DB)/19 °C (WB)
Air temperature Designed air temperature
Outdoor: 7 °C (DB)/6 °C (WB) Outdoor: 35 °C (DB)
Condensation temperature 40 °C ~ 45 °C Evaporation temperature 6 °C
Subcooling temperature 3 °C Overtemperature 5 °C

(1) The output of the exchanger must be designed with the following input parameters.
(2) Max. allowed distribution lenght to achieve a maximum volume of 10 m (see Timing Limit Limits).

25
Exchanger design pressure = 4.15 MPa. Pressure resistance ≥ 12.45 MPa (3 x design pressure).

3~400V 50Hz

RAS‑4XHNP1E RAS‑5XHNP1E RAS‑6XHNP1E RAS‑8XHNPE RAS‑10XHNPE

10.0 (4.5‑11.2) 12.5 (5.7‑14.0) 14.0 (6.0‑16.0) 20.0 ( 8.0‑22.4) 25.0 (10.0‑28.0)


11.2 (5.0‑14.0) 14.0 (5.0‑18.0) 16.0 (5.0‑20.0) 22.4 (6.3‑28.0) 28.0 (8.0‑35.0)
4.68 3.81 3.41 3.56 3.07
5.16 4.55 4.23 4.21 3.84

47 (43) / 49 48 (44) / 50 48 (45) / 50 57 (55) / 59 58 (56) / 60

63 64 65 76 76
80 90 100 127 134
1380x950x370 1380x950x370 1380x950x370 1380x950x370 1380x950x370
103 103 103 136 138
15 15 15 30 30
14 14 16 24 24
3.2 5.0 6.3 8.6 12.6
3.2 4.7 5.8 8.1 11.3
5x 2.5 5x 2.5 5x 2.5 5x 6.0 5x 6.0

2x 0.75 2x 0.75 2x 0.75 2x 0.75 2x 0.75

Ø9.52 (3/8) / Ø9.52 (3/8) / Ø9.52 (3/8) / Ø9.52 (3/8) / Ø12.7 (1/2) /
Ø15.88 (5/8) Ø15.88 (5/8) Ø15.88 (5/8) Ø25.4 (1) Ø25.4 (1 )
5 5 5 5 5

30 30 30 30 30
Side Flow VRF

75 75 75 100 100

30 / 20 30 / 20 30 / 20 30 / 20 30 / 20

4.1 - 8.56 4.2 - 8.77 4.2 - 8.77 5.7 - 11.9 6.2 - 12.95
Scroll DC inverter Scroll DC inverter Scroll DC inverter Scroll DC inverter Scroll DC inverter
EASY INSTALLATION
WITHOUT USING THE
ROOF: 30% MORE
COMPACT

AIR CONDITIONING FOR 12


DIFFERENT SPACES WITH
INDEPENDENT CONTROL

LIMITATION OF
ELECTRICITY
CONSUMPTION,
REGULATING BETWEEN
ACTUAL PIPE LENGTH 100%, 70% AND 50% OF
75~100* THE NOMINAL VALUE
MINI VRF

MINI VRF

Because of its compact design, its installation is even


easier even in the most demanding places.
Capable of working with outdoor temperatures up to
-20ºC in heating mode and up to 46ºC in cooling mode.

It controls the climate of all kinds of establishments


without needing to install the outdoor unit on the roof.
Thanks to its size, it even fits on a terrace.

390mm

27
1,650mm

SET FREE
10 HP

BASEMENT

The 3-blade fan makes it the quietest unit on the market, Compatible
with noise reduction of up to 4 dB(A). This way, it does not bother indoor units

the neighbors.

FS(V)N(Y)3E 4 to 6 HP for facilities of up to 15500 kW.


FSNM 8 to 12 HP for facilities of up to 33500 kW.
EER–COP: 6.56–4.24*
Compatible with all HITACHI control and management systems.
Side Flow VRF

*Depending on model
OUTDOOR UNIT
SET

FREE MINI
FSVN3E / FSNY3E
RAS-4~6FSVN3E / RAS-4~6FSNY3E

Characteristics

Scroll DC Inverter Compressor Automatic control of electricity consumption


More efficiency at partial loads and at low speed. It can be adjusted between 100%, 70% and 50% of the
nominal value.
“Side Flow” Technology
The fan speed is distributed evenly thanks to this Wider operating range
technology. From -5ºC to 46ºC in cooling and from -20ºC to 15ºC in
heating.
Flexibility
Compatible with all System Free indoor units and Very high flow fan
individual and/or centralized management systems. More aerodynamic than previous models. It has a larger
surface in contact with the air and a better angle of
rotation, which prevents turbulence and allows the
installation of the fan at a lower level.

AUTOMATIC CONTROL OF ENERGY CONSUMPTION.


THIS FUNCTION MAINTAINS THE ADJUSTED CURRENT VALUE.

ADJUSTED CURRENT
VALUE

ELECTRICITY THIS VALUE CAN BE


CONSUMPTION SELECTED FROM
50%, 70% OR 100% OF
THE NOMINAL VALUE.

MORNING DAY NIGHT

Automatic consumption control


Guaranteed performance

COMPRESSOR
+15 +46 INTERFACE
H-LINK II
OWN
-20 -5


FSVN3E
FSNY3E
SINGLE PHASE THREE-PHASE
Outdoor Units RAS - 4FSVN3E RAS - 5FSVN3E RAS - 6FSVN3E RAS - 4FSNY3E RAS - 5FSNY3E RAS - 6FSNY3E

Maximum number of units Connectible 6 (8)* 8 (10)* 9 (12)* 6 (8)* 8 (10)* 9 (12)*

Nominal power Cooling kW 11.20 (5.60~11.20) 14.00 (7.00~14.00) 15.50 (7.80~15.50) 11.20 (5.60~11.20) 14.00 (7.00~14.00) 15.50 (7.80~15.50)
(min-max ) (1) Heating kW 12.50 (6.30~12.50) 16.00 (8.00~16.00) 18.00 (9.00~18.00) 12.50 (6.30~12.50) 16.00 (8.00~16.00) 18.00 (9.00~18.00)

Absorbed nominal power Cooling kW 2.75 3.88 4.67 2.72 3.84 4.62
(min-max) Heating kW 3.03 4.20 4.90 3.00 4.16 4.85
EER - COP 4.07 - 4.13 3.61 - 3.81 3.32 - 3.67 4.12 - 4.17 3.65 - 3.85 3.35 - 3.71

Sound Pressure Level Cooling dB(A) 49 (45) 51 (47) 51 (48) 49 (45) 51 (47) 51 (48)
(very low - low- medium -
high) (2) Heating dB(A) 51 53 51 53

Airflow m³/h 5400 5400 6000 5400 5400 6000


Power supply 230 V - 1 Ph - 50 Hz 230 V - 1 Ph - 50 Hz 230 V - 1 Ph - 50 Hz 400 V - 3 Ph +N - 50 Hz 400 V - 3 Ph +N - 50 Hz 400 V - 3 Ph +N - 50 Hz
Maximum length m 75 75 75 75 75 75
Maximum height m 30 30 30 30 30 30
Pipe diameter (Liquid - Gas) inches 3/8 - 5/8 3/8 - 5/8 3/8 - 5/8 3/8 - 5/8 3/8 - 5/8 3/8 - 5/8
kg - GWP
Refrigerant R410A Charge 3.60 - 7.52 3.60 - 7.52 3.60 - 7.52 3.60 - 7.52 3.60 - 7.52 3.60 - 7.52
eq Ton

29
Compressor Scroll
Refrigerant R410A

RAS-4~6FSVN3E 100 kg

RAS-4~6FSNY3E 102 kg

370 mm
1380 mm

950 mm
Side Flow VRF

(1) The nominal cooling and heating capacity is the combined capacity of the SET FREE system and is based on EN14511:
- Cooling: Indoor temperature 27°C DB ; 9°C WB , Outdoor temperature 35°C DB
To create the energy label visit our - Heating: Indoor temperature 20°C DB; outdoor temperature 7°C DB, 6°C WB.
website www.hitachiaircon.es and use - Pipe length: 7.5 m ; Height at 0 m.
our Hitachi ErP AcTive Tool application. (2) The sound level measurement is performed in an anechoic camera at 1 m from the frontal surface of the unit and at 1.5 m from the ground level.
REFRIGERANT
DISTRIBUTION

FSVN3E / FSNY3E
RAS-4~6FSVN3E / RAS-4~6FSNY3E

Refrigerant distribution in line and collector


(only Mini set Free FS(V)N(Y)3E series)

RAS-5FS(V)N(Y)3E
ELEMENT RAS-4FS(V)N(Y)3E
RAS-6FS(V)N(Y)3E
Maximum pipe length Real length (L1) ≤ 75
between the outdoor unit and
the farthest indoor unit Equivalent length ≤ 95

Maximum pipe length from frist branch and furthest unit (L2) ≤40
Maximum length from the a) collector ≤15
first branch pipe to each
indoor unit (L3) b) distribution in line ≤10

Total pipe length (L3 1 + L3 2 + L3 3 …) ≤125 ≤135


Maximum height difference If the indoor unit is lower than the indoor unit ≤30
between the outdoor
unit and the indoor unit If the indoor unit is higher than the indoor unit ≤30

Maximum height difference between the indoor units (H1) ≤15

Maximum height difference between the multikit and indoor unit (H2) ≤5
MH-84AN (4 ports)
a) collector
Branch reference MH-108AN (8 ports)
b) distribution in line E-102SN3
ACCESSORIES

FSVN3E / FSNY3E
RAS-4~6FSVN3E / RAS-4~6FSNY3E

Accessories code list

Reference Compatible with Description Picture

DBS-26 RAS-FS(V)N(Y)3E Drain pipe

AG-335A RAS-FS(V)N(Y)3E Air guide

31
WSP-335A RAS-FS(V)N(Y)3E Wind shield

ASG-NP335F RAS-FS(V)N(Y)3E Snow shield, air outlet (zinc)

ASG-NP335FS2 RAS-FS(V)N(Y)3E Snow shield, air outlet (stainless steel)

ASG-NP280BS2 RAS-FS(V)N(Y)3E Snow shield, back air inlet (stainless steel)

ASG-NP280LS2 RAS-FS(V)N(Y)3E Snow shield, left air inlet (stainless steel)

E-102SN3 SET FREE Branch

MH-84AN SET FREE Header

MH-108AN SET FREE Header


Side Flow VRF
OUTDOOR UNIT
SET

FNSM
FREE MINI
RAS-8~12FSNM

Characteristics

Unbeatable in kW per m2 installed, design Scroll DC Inverter Compressor


and size More efficiency at partial loads and at low speed.
65% more power on the same surface compared to
Flexibility
Top-Flow units, in addition to being 43% lighter.
Compatible with all System Free indoor units, HITACHI
Easy installation management systems and building management software.
With a width of only 390 mm, it can be installed in any
Compressor speed control
small space, such as a balcony, as it also operates very
It controls between 20 and 100 Hz for coverage, also, with
quietly.
the needs of smaller spaces.

390mm
1,650mm

SET FREE
10 HP

BASEMENT

Pipe height and length


Guaranteed performance

COMPRESSOR
+15 +46 INTERFACE
H-LINK II
OWN
-20 -5


FNSM

SET FREE MINI SIDE FLOW


Outdoor Units RAS - 8FSNM RAS - 10FSNM RAS - 12FSNM

Maximum number of units Connectible 10 10 10


Cooling kW 22.40 28.00 33.50
Nominal power (1)
Heating kW 25.00 31.50 37.50
Cooling kW 6.30 8.30 10.70
Absorbed nominal power
Heating kW 5.90 7.80 9.90
EER - COP 3.56 - 4.24 3.37 - 4.04 3.13 - 3.79

Sound pressure level (very Cooling dB(A) 53 56 59


low - low - medium - high) (2) Heating dB(A) 55 58 61
Airflow m³/h 7260 9000 9780
Power supply 380~415 V - 3 Ph +N - 50 Ph
Maximum length m 100 100 100
Maximum height m 40/30 40/30 40/30
Pipe diameter (Liquid - Gas) inches 3/8 - 3/4 1/2 - 7/8 1/2 - 1 1/8
kg - GWP
Refrigerant R410A Charge 5.0 - 10.44 5.5 - 11.48 6.5 - 13.57
eq Ton

33
Compressor Scroll Scroll Scroll
Refrigerant R410A R410A R410A

RAS-8~10FSNM 170 kg

RAS-12FSNM 173 kg

390 mm
1650 mm

1100 mm
Side Flow VRF

(1) The nominal cooling and heating capacity is the combined capacity of the SET FREE system and is based on EN14511:
- Cooling: Indoor temperature 27°C DB ; 9°C WB , Outdoor temperature 35°C DB
To create the energy label visit our - Heating: Indoor temperature 20°C DB; outdoor temperature 7°C DB, 6°C WB.
website www.hitachiaircon.es and use - Pipe length: 7.5 m ; Height at 0 m.
our Hitachi ErP AcTive Tool application. (2) The sound level measurement is performed in an anechoic camera at 1 m from the frontal surface of the unit and at 1.5 m from the ground level.
REFRIGERANT
DISTRIBUTION

FNSM
RAS-8~12FSNM

Refrigerant distribution in line and collector


(only Mini set Free FSMN series)

ELEMENT Max. Lenght (m)


Actual 100
Lenght between OU and furthest IU (L)
Equivalent 120

Total pipe lenght 250

Lenght between main branch and furthest unit (Li) 40

OU higher than IU 40
Height difference between IU and OU
OU lower than IU 30
Height difference between IU 15
ACCESSORIES

FNSM
RAS-8~12FSNM

Accessories code list

Reference Description Picture

DBS-26 Drain pipe

E-102SN4 Branch

35
E-162SN4 Branch

MH-84AN1 Header

MH-108AN Header

Side Flow VRF



JOHNSON CONTROLS HQ HOLDING

CUSTOMER SERVICE HITACHI. CERTIFIED QUALITY


Johnson Controls
Email : [email protected]

SPARE PARTS
www.easyparts.johnsoncontrols.com
Tel : +44 (0) 1268 246 400
Email : [email protected] HITACHI. TOTAL WARRANTY ON COMPRESSORS

WARRANTY COMPRESSOR

www.hitachi-hvac.com/en

The specifications of this catalog may change without prior notice to allow Find the products Hitachi
HITACHI C&H to incorporate the latest innovations for its customers. The
C&H with the best service
information contained in this catalog is merely informative. HITACHI C&H declines
any responsibility in the broadest sense, for damage, direct or indirect, arising and conditions at your
from the use and / or interpretation of the recommendations in this catalog Hitachi Distributor.