This document provides information on various types of power contactors from different manufacturers, including their ratings, technical specifications, and part numbers. It includes general information, accessories, spares, terminal arrangements, and dimensions for contactors ranging from MNX 9 to MNX 550, ML0 to ML12, MR1, MU1/MU2, MC01-MC99, MN0, MM00/MM01, and MN9W to MN25W. Salient features are highlighted for MNX contactors, including conformance to standards, compartment construction for safety, aesthetics, suitability for tropical conditions, terminal marking, and accessories.

Uploaded by

kristin salavia
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
921 views61 pages

LT Contactor Ranges PDF

This document provides information on various types of power contactors from different manufacturers, including their ratings, technical specifications, and part numbers. It includes general information, accessories, spares, terminal arrangements, and dimensions for contactors ranging from MNX 9 to MNX 550, ML0 to ML12, MR1, MU1/MU2, MC01-MC99, MN0, MM00/MM01, and MN9W to MN25W. Salient features are highlighted for MNX contactors, including conformance to standards, compartment construction for safety, aesthetics, suitability for tropical conditions, terminal marking, and accessories.

Uploaded by

kristin salavia
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 61

POWER CONTACTORS

MNX 9 to MNX 32 Page MNX 45 to MNX 550 Page

General Information 6/1, 6/2 General Information 6/2

6 (ac operation & dc operation)

Accessories 6/4,6/5 Accessories 6/4,6/5

Spares 6/6 Spares 6/6

Catalogue No. suffixes 6/7 Catalogue No. suffixes 6/7

Terminal Arrangements 6/42 Terminal Arrangements 6/42

Technical Data 6/23 - 6/27 Technical Data 6/24-6/26

Overall Dimensions 6/45 Overall Dimensions 6/46-6/47

ML0 to ML3 Page ML4 to ML12 Page

General Information 6/8 General Information 6/8

Accessories 6/9 Accessories 6/9

Spares 6/10 Spares 6/10

Catalogue No. suffixes 6/11 Catalogue No. suffixes 6/11

Technical Data 6/30 Technical Data 6/31

Overall Dimensions 6/51 Overall Dimensions 6/52-6/53

www.LNTEBG.com
POWER CONTACTORS

MR1 Page MU1 / MU2 Page

General Information 6/16 General Information 6/16

(ac operation & dc operation) 6


Technical Data 6/37 Accessories 6/21

Overall Dimensions 6/57 Spares 6/17

Technical Data 6/34

Overall Dimensions 6/48

MC01 - MC12 Page MC21 - MC 99 Page

General Information 6/19 General Information 6/19

Accessories 6/20 Accessories 6/20

Spares 6/22 Spares 6/22

Technical Data 6/35 Technical Data 6/35-6/36

Overall Dimensions 6/55 Overall Dimensions 6/56

www.LNTEBG.com
CONTROL CONTACTORS

MN0 Page MM00, MM01 Page

General Information 6/12 General Information 6/12

6 Accessories 6/13 Accessories 6/13

Spares 6/14 Spares 6/14

Catalogue No. suffixes 6/15 Catalogue No. suffixes 6/15

Terminal Arrangements 6/44 Technical Data 6/32

Technical Data 6/33 Overall Dimensions 6/50, 6/54

Overall Dimensions 6/50

CONTACTORS FOR SPECIAL APPLICATIONS

MN9W to MN25W Page MN16C, 32C Page

General Information 6/3 General Information 6/3

Accessories 6/4,6/5 Accessories 6/4,6/5

Spares 6/6 Spares 6/6

Catalogue No. suffixes 6/7 Catalogue No. suffixes 6/7

Technical Data 6/28 Terminal Arrangements 6/43

Overall Dimensions 6/58 Technical Data 6/29

Overall Dimensions 6/49

www.LNTEBG.com
SALIENT FEATURES OF MNX CONTACTORS

✦ Conform to standards IEC 60947-4-1, BS EN 60947-4-1, IS 13947-4-1

✦ Compart Construction ensures Complete Safety

✦ High aesthitic standards.

✦ Suitable for tropical conditions, ensures reliable performance in high ambient temperature, humidity etc.

✦ Enclosed construction ensures protection of contact & magnet pole faces from dust and foreign particles.

✦ Alphanumeric terminal marking eliminates wiring error.

✦ Coil voltage indication on coil terminals makes identification easy. 6


✦ Suitable for snap-fit mounting on 35mm din rail upto 80 Amps.

✦ Front ON/OFF mechanical indication provides visual inspection of the state of the contactor.

✦ Main terminals are suitable for aluminium busbars & lugs so as to give higher terminal capacity.

✦ Common accessories for multiple ratings of contactors.

✦ Easy contact/coil accessibility and replacement.

✦ Build-in protection to coil against overvoltage & undervoltage conditions.

www.LNTEBG.com 6/1
CONTACTORS - TYPE MNX
POWER CONTACTORS
Conformance to IS 13947 (Part 4/Sec.1) and IEC:60947-4-1

Contactor Ie Ie Motor rating Built in Qty Wt Catalogue No. *


Type AC-3 AC-1 at 50Hz auxiliary per approx.per
220V 380V 500V contacts Packing Contactor
240V 415V

AC operation

[A] [A] [KW] [KW] [KW] NO NC [No.] [Kg]

9 25 2.2 4 5.5 1 — 10 0.37 CS94106….


9 25 2.2 4 5.5 — 1 10 0.37 CS94107….
MNX 9/12/18 12 30 3 4 7.5 1 — 10 0.37 CS94108….

6 12 30 3 4 7.5 — 1 10 0.37 CS94109….


18 30 4 7.5 9.3 1 — 10 0.37 CS94100….
18 30 4 7.5 9.3 — 1 10 0.37 CS94101….

25 45 6.5 11 15 1 1 10 0.37 CS94218….


MNX 25/32/40
32 55 7.5 17 18.6 1 1 10 0.37 CS94219….
40 55 11 22.5 22.5 1 1 10 0.37 CS94190….

45 85 12.5 25 25 2 2 1 1.20 ST19000….


50 85 12.5 25 25 2 2 1 1.20 ST19001....
70 100 18.6 33.5 37 2 2 1 1.20 ST19002….
MNX 45/50/70/80 80 100 22 40 51 2 2 1 1.20 ST19003….

95 160 25 45 59 2 2 1 3.10 CS94136….


110 160 30 55 75 2 2 1 3.10 CS94137….
140 160 40 75 90 2 2 1 3.10 CS94138….

MNX 95/110/140

185 250 55 90 110 2 2 1 5.30 CS94139….


225 300 63 110 132 2 2 1 5.30 CS94140….

MNX 185/225

265 350 80 147 180 2 2 1 9.80 CS94142….


325 400 90 180 200 2 2 1 9.80 CS94143….
400 425 110 200 250 2 2 1 9.80 CS94144….
1)
550 650 160 315 2 2 1 10.00 CS94145….
MNX 265/325/400/550

DC operation

16 30 7.5 1 — 1 0.68 SS94649….


16 30 7.5 — 1 1 0.68 SS94650….
MN 16dc
* For Voltage suffix refer page 6/7
1) Data available on request
6/2 www.LNTEBG.com
CONTACTORS - TYPE MN
WIDE BAND CONTACTORS
Conformance to IS 13947 (Part 4/Sec.1) and IEC:60947-4-1

✦ Suitable for applications where wide fluctuations in control supply voltage are observed.
✦ Wide band operation 55-110%

Contactor Ie Ie Motor rating Built in Qty Wt Catalogue No. *


Type AC-3 AC-1 at 50Hz,415V auxiliary per approx. per
contacts Packing Contactor

AC operation

[A] [A] [KW] NO NC [No.] [Kg]

9 25 4 1 — 10 0.37 SS94771….
9 25 4 — 1 10 0.37 SS94772….
12 30 5.5 1 — 10 0.37 SS94773…. 6
12 30 5.5 — 1 10 0.37 SS94774….
MN 9/12/16W 16 30 7.5 1 — 10 0.37 SS94679….
16 30 7.5 — 1 10 0.37 SS94680….

25 45 11 1 1 10 0.60 SS94655….

MN 25W
* For Voltage suffix refer page 6/7

CONTACTORS - TYPE MN
CONTACTORS FOR CAPACITOR SWITCHING
Conformance to IS 13947 (Part 4/Sec.1) and IEC:60947-4-1

✦ Suitable for capacitor switching of single capacitor as well as auto-switching of a bank of capacitors.
✦ Increases the life of capacitors by reducing the switching surge.
✦ 2-auxillary contacts built-in.

Contactor Ie Built in Qty Wt Catalogue No. *


Type AC-6b AC-1 auxiliary per approx.
contacts Packing per Cont.

AC operation

kVAR [A] NO NC [No.] [Kg]

10 25 1 1 1 0.62 SS94624….

MN 16C

MN 32C 25 50 1 2 1 1.00 SS94652….

* For Voltage suffix refer page 6/7


www.LNTEBG.com 6/3
ACCESSORIES

Auxillary Contact Block Ie AC-15 Ie Auxiliary contact Qty Wt Catalogue No.


at 415V AC-12 combinations

[A] [A] NO NC [No.] [Kg]

1 — 10 0.03 CS9412OOOO0
— 1 10 CS94121OOOO
4 10 2 — 10 CS94117OOOO
1 1 10 CS94118OOOO
— 2 10 CS94119OOOO
MN A1 4 — 10 0.03 CS94112OOOO
3 1 10 CS94113OOOO
4 10 2 2 10 CS94114OOOO
1 3 10 CS94115OOOO
6 — 4 10 CS94116OOOO
4 — 10 0.03 0.05 CS9412OOOO0
— 1 10 CS94121OOOO
4 10 2 — 10 CS94117OOOO
MNX-A12T-2 MNX-A12T-4 1 1 10 CS94118OOOO
— 2 10 0.03 CS94119OOOO
4 — 10 CS94112OOOO
3 1 10 CS94113OOOO
4 10 2 2 10 CS94114OOOO
1 3 10 CS94115OOOO
— 4 10 CS94116OOOO
4 10 1 1 1 0.05 SS94201OOOO1)
MNX-A33S-2 SS94202OOOO1)
1 1 SS94203OOOO2)
SS94204OOOO2)
4 10 1 1 1 0.05 CS94205OOOO1)
1 1 CS94206OOOO1)
1 1 CS94207OOOO2)
1 1 CS94208OOOO2)

MNX-A46S-2

Surge Suppressor For Contactor type Rated control voltage Qty Wt Catalogue No.

Us [No.] [Kg]

MNX 9 - MNX 18 24 - 48V 5 0.025 CS94166 JOOO


MNX 25, MNX 32 110 - 240V CS94166 BOOO
360-415V CS94166 DOOO

MN 16C,MN 32C 24 - 48V 5 0.022 SS94623 JOOO


MN16dc 110 - 240V SS94623 BOOO
360-415V SS94623 DOOO

MNX 45 - MNX 80 24 - 48Vdc 5 0.022 SS947815OOO


110 - 220Vdc SS947812OOO

MNX 95 110V 5 0.15 CS94164AOOO


MNX 110,MNX 140 220-240V CS94164BOOO
MN S1/S2/S4/S6 MNX 185,MNX 225 360-525V CS94164DOOO
MNX-S12D-0
MNX-S33B-0 MNX 265 110V 5 0.15 CS94165AOOO
MNX-S45B-0 MNX 325 220-240V CS94165BOOO
MNX-S66B-0
MNX 400 360-525V CS94165DOOO

* No Surge Supressor required for MNX 550 Contactor.


1) Provided along with Contactor
2) Additional auxiliary contact block to make 4NO+4NC combination
6/4 www.LNTEBG.com
ACCESSORIES

Mechanical For Contactor type Qty Wt Catalogue No.


Interlock per approx. per
Packing accessory

[No.] [Kg]

MNX 9, MNX 12, MNX 18, 5 0.04 CS94166OOOO


MNX 25, MNX 32

MNX-M12S-0

MN 9W, MN 12W, MN 16W 5 0.04 SS94071OOOO


MN 25W
MN 16C, MN 32C
6

MN 16dc 1 — SS94766OOOO
MN-M1

MN 45 / MNX 45 / MNX 50 1 0.45 CS94197OOOO


MN 65 / MNX 70 / MNX 80

MNX-M33B-0

1 2.90 CS94193OOOO
MN 95 / MNX 95
MN 110 / MNX 110
MN 140 / MNX 140
MNX-M44B-0

MN 185 / MNX185 1 — CS94194OOOO


MN 225 / MNX 225

MNX-M55B-0

MN 265 / MNX 265 1 5.50 CS94195OOOO


MN 325 / MNX 325
MN 400 / MNX 400

MNX-M66B-0 MN 550 / MNX 550 1 5.50 CS94196OOOO

www.LNTEBG.com 6/5
SPARES

For Contactor Qty Wt Catalogue No. *


SPARE COILS type per approx.per
Packing coil
[No.] [Kg]

AC operation
MNX 9, 12, 18, 25, 32
MNX 9, MNX 12, MNX 18, MNX 25, MNX32 10 0.09 CS94105….

MN 9W, MN 12W, MN 16W 10 0.09 SS94191....


MN 16C
MN 9W, 12W, 16W, 16C
MN 25W, MN 32C 10 0.12 SS94192….

MNX 45, MNX 50 10 0.12 CS94192….

6 MN 25W, MN 32C
MNX 70, MNX 80

MNX 95 1 0.20 CS94196….


MNX 110
MNX 140
MNX 45-80
MNX 185 1 0.20 CS94194….
MNX 225

MNX 265 1 0.64 CS94195….


MNX 95-140
MNX 325
MNX 400

MNX 265-400 MNX 550 1 0.70 CS94193….

DC operation

MN16dc 1 —7 SS94651….
MNX 550

SPARE KITS Contacts with mounting parts

For Contactor Contents Qty Wt Catalogue No.


type [No.] [Kg]
MNX 9 Set of 3 moving contacts 25sets 0.04 CS94123OOOO
MN 9W and 6 fixed contacts 25sets 0.04 SS94702OOOO
MNX 12 with hardware. 25sets 0.04 CS94124OOOO
MN 12W 25sets 0.04 SS94625OOOO
MNX18 25sets 0.04 CS94125OOOO
MN 16dc
MN 16C, MN 16W 25sets 0.04 SS94703OOOO
MNX 25 25sets 0.05 CS94127OOOO
MN 25W 25sets 0.05 SS94678OOOO
MN 32, MN 32C 25sets 0.05 SS94626OOOO
MNX 45 10sets 0.12 CS94149OOOO
MNX 50 10sets 0.12 CS94150OOOO
MNX 70 10sets 0.12 CS94151OOOO
MNX 80 1set 0.3 CS94152OOOO
MNX 95 1set 0.3 CS94153OOOO
MNX 110 1set 0.34 CS94154OOOO
MNX 140 1set 0.4 CS94155OOOO
MNX 185 1set — CS94156OOOO
MNX 225 1set — CS94157OOOO
MNX 265 1set 1 CS94159OOOO
MNX 325 1set 1.1 CS94160OOOO
MNX 400 1set 1.1 CS94161OOOO
MNX 550 1set — CS94162OOOO
* For Voltage suffix refer page 6/7
6/6 www.LNTEBG.com
Catalogue No. suffixes for rated control voltages

ORDERING INFORMATION:
Example for Contactor : MNX 9 Contactor - 240V, 50Hz, 1No Example for Spare Coil : MNX 18 Spare Coil - 360V, 50Hz
Ordering Information - CS94106BOOO Ordering Information - CS94105COOO

AC operation Contactor type


Rated control MNX 9, MNX 12, MNX 18 MN 25W MNX 45 MNX 95 MNX 185 MNX 265 MNX 550
voltage (Us) MNX 25, MNX 32, MN 9W, MN 32C MNX 50 MNX 110 MNX 225 MNX 325
VAC MN 12W, MN 16W, MN 16C MNX 70 MNX 140 MNX 400
MNX 80
Coils at 50 Hz

24 GOOO GOOO GOOO GOOO — — —


42 HOOO HOOO HOOO HOOO — — —
110 AOOO AOOO AOOO AOOO AOOO AOOO AOOO
220 KOOO KOOO KOOO KOOO KOOO KOOO KOOO
240 BOOO BOOO BOOO BOOO BOOO BOOO BOOO
360 COOO COOO COOO — — — — 6
380 LOOO LOOO LOOO — — — —
415 DOOO DOOO DOOO DOOO DOOO DOOO DOOO
525 MOOO MOOO MOOO MOOO MOOO MOOO —

DC operation Contactor type


Rated control MN16dc
voltage (Us)
VDC

24 4OOO
42 6OOO
48 5OOO
110 1OOO
220 2OOO

Note : 60Hz coils available on request.

www.LNTEBG.com 6/7
POWER CONTACTORS - TYPE ML
Conformance to IS 13947 (Part 4/Sec.1) and IEC:60947-4-1

✦ Rugged construction for reliable operating in high ambients,humidity,undervoltage conditions.


✦ Built in 2NO+2NC auxiliary contacts.

Contactor Ie Ie Motor rating Built in Qty Wt Catalogue No. *


Type AC-3 AC-1 at 50Hz,415V auxiliary per approx.per
contacts Packing Contactor

AC operation

[A] [A] [KW] NO NC [No.] [Kg]

12 16 5.5 2 2 10 0.50 SS90975….

6 16 25 7.5 2 2 10 0.50 SS90851….

ML0/1/1.5
25 25 11 2 2 10 0.50 SS91851….

32 40 15 2 2 10 0.95 SS90701….

ML2/3 40 45 22 2 2 10 0.95 SS90721….

70 100 37 2 2 1 2.90 SS90910….

110 125 55 2 2 1 3.00 SS90921….


ML4/6

200 250 110 2 2 1 9.00 SS90935….

300 400 168 2 2 1 9.2 SS91010….

ML10/12

* For voltage suffix refer page 6/11


6/8 Website: www.LNTEBG.com
ACCESSORIES

Auxiliary Contact Block Ie Ie Auxiliary contact Qty Wt Catalogue No.


AC-15 AC-12 combinations per approx.per
at 415V Packing accessory

[A] [A] NO NC [No.] [Kg]

4 10 1 1 10 0.10 SS91494OOOO

For contactor type ML4/6


(Side mounted)

4 10 1 1 10 0.10 SS91474OOOO

For contactor type ML10/12


(Side mounted)

✦ ML4/6/10/12 contactors are available with built in 2NO+2NC auxiliary contact block. Additional 1NO+1NC block
can be fitted on either side ,providing 4NO+4NC auxiliary contacts.

www.LNTEBG.com 6/9
SPARES

SPARE COILS For Contactor Qty Wt Catalogue No. *


type per approx.per
Packing coil
[No.] [Kg]

AC operation

ML0 10 0.076 SS90873….

ML1

ML1.5
ML1-1.5

ML2 10 0.22 SS90545….

ML3
6
ML4 1 0.31 SS91258….
ML2-3
ML6

ML10 1 1.20 SS91011….

ML12

ML4-6

SPARE KITS Contacts with mounting parts

For Contactor Contents Qty Wt Catalogue No.


type per approx.per
Packing set
[No.] [Kg]

ML0 Set of 3 moving contacts 50sets 0.04 SS90978OOOO

ML1 and 6 fixed contacts 50sets 0.05 SS90896OOOO

ML1.5 with hardware. 50sets 0.05 SS91467OOOO

ML1-1.5
ML2 50sets 0.05 SS90544OOOO

ML3 50sets 0.06 SS90848OOOO

ML4 25sets 0.18 SS91660OOOO


ML2-3 ML6 25sets 0.24 SS91670OOOO

ML10 1set 1.10 SS90936OOOO

ML12 1set 1.20 SS91127OOOO


ML4-6

* For voltage suffix refer page 6/11


6/10 www.LNTEBG.com
Catalogue No. suffixes for rated control voltages

ORDERING INFORMATION:
Example for Contactor : ML2 Contactor - 240V, 50Hz Example for Spare Coil : ML4 Spare Coil - 110V, 50Hz
Ordering Information - SS90701BOOO Ordering Information - SS91258AOOO

AC operation Contactor type

Rated control ML0 ML2 ML4 ML10


voltage Us ML1 ML3 ML6 ML12
VAC ML1.5

Coils at 50 Hz

12 FOOO — — —
24 GOOO — — —
42 HOOO HOOO — —
110 AOOO AOOO AOOO AOOO 6
220 — KOOO KOOO KOOO
220/230 KOOO — — —
240 — BOOO BOOO BOOO
240/250 BOOO — — —
320 ROOO ROOO — —
360 COOO COOO — —
380 LOOO LOOO — —
415 — — DOOO DOOO
415/440 POOO POOO — —
525 MOOO MOOO MOOO MOOO

www.LNTEBG.com 6/11
CONTROL CONTACTORS - TYPE MN
Conformance to IS 13947 (Part 5/Sec.1) and IEC:60947-5-1

✦ Suitable to have maximum 8 NO to 8 NC Contact combinations.


✦ Suitable for snap fit mounting on 35mm Din rail.
✦ Alphanumeric terminal marking eliminates wiring error.

Contactor Ie Ie Built in Qty Wt Catalogue No. *


Type AC-1 AC-15 auxiliary per approx.per
contacts Packing Contactor

AC operation

[A] NO NC [No.] [Kg]

10 4 4 — 10 0.39 SS94660….
3 1 SS94661….
2 2 SS94662….
1 3 SS94663….
MN0 AC — 4 SS94664….
6 DC operation

10 4 4 — 10 0.68 SS94665….
3 1 SS94666….
2 2 SS94667….
1 3 SS94668….
— 4 SS94669….
MN0 DC
* For Voltage suffix refer page 6/15

CONTROL CONTACTORS - TYPE MM


✦ Suitable to have as many as 25 convertible contact combinations using addon blocks.
✦ Ergnomical design gives mounting of contactors side by side with ease of inspection of contacts.
✦ Clear distinction between NO and NC contacts from front by a red dot on NC contact.

Contactor Ie Ie Ie Built in Qty Wt Catalogue No. *


Type AC-3 AC-1 AC-15 auxiliary per approx.per
contacts Packing Contactor

AC operation

[A] [A] NO NC [No.] [Kg]

7.5 10 4 2 2 10 0.43 SS92002….


7.5 10 4 8 — 10 0.48 SS92010….
7 1 SS92011….
6 2 SS92012….
5 3 SS92013….
MM00/01 AC 4 4 SS92014….

DC operation

— 10 4 2 2 10 0.65 SS92007….

— 10 4 8 — 10 0.65 SS92820….
7 1 SS92821….
6 2 SS92822….
5 3 SS92823….
MM00/01 DC 4 4 SS92824….

* For Voltage suffix refer page 6/15


6/12 www.LNTEBG.com
ACCESSORIES

Auxiliary Contact Block Ie Ie Auxiliary contact Qty Wt Catalogue No.


AC-15 AC-12 combinations per approx.per
at 415V Packing accessory

[A] [A] NO NC [No.] [Kg]

1 — 10 0.10 SS94715OOOO
— 1 10 SS94716OOOO
4 10 2 — 10 SS94080OOOO
1 1 10 SS94081OOOO
— 2 10 SS94082OOOO
4 — 10 SS94083OOOO
MNA1 3 1 10 SS94084OOOO
For contactor type 2 2 10 SS94085OOOO
MN0ac,MN0dc 1 3 10 SS94086OOOO
(Top mounted)
— 4 10 SS94087OOOO
6
Surge Suppressor For Contactor Rated control voltage Qty Wt Catalogue No.
type per approx. per
Packing accessory
Us [No.] [Kg]
MN0 ac 24 - 48V 5 0.022 SS94623 JOOO
110 - 240V SS94623 BOOO
360 - 415V SS94623 DOOO
MN0 dc 24 - 48Vdc SS947815OOO
MNS1/S2 110 - 220Vdc SS947812OOO
Mechanical Interlock For Contactor type Qty Wt Catalogue No.
per approx. per
Packing accessory
[No.] [Kg]

MN0ac 5 0.04 SS94071OOOO

MN0dc 1 — SS94766OOOO
Auxillary Contact Block Ie Auxiliary contact Qty Wt Catalogue No.
AC-15 combinations per approx.per
415V,50Hz Packing accessory

[A] NO [No.] [Kg]

4 1 10 0.005 SS92020OOO

For contactor type


MM00AC,MM00DC

Rail mounting kit For Contactor Version Qty Wt Catalogue No.


type per approx. per
Packing accessory

[No.] [Kg]

MM00 ac with mounting screws 10 0.032 SS91355OOOO


MM01 ac and washers.

www.LNTEBG.com 6/13
SPARES

SPARE COILS For Contactor Qty Wt Catalogue No. *


type per approx.per
Packing coil
[No.] [Kg]

AC operation

MM00 10 0.09 SS91353….


MM01

MN0 10 0.09 SS94191….


MN0

6 DC operation

MM00 10 0.30 SS91354….


MM01

MN0 10 — SS94651….

MN0DC

SPARE KITS Contacts with mounting parts

For Contactor Contents Qty Wt Catalogue No.


type per approx.per
Packing set
[No.] [Kg]

MM00AC Set of 3 moving contacts 1 set 0.04 SS91352OOOO


MM01AC and 6 fixed contacts
with hardware.

MN0 1)

MN0 DC 1)

* For voltage suffix refer page 6/15


1) Available on request.
6/14 www.LNTEBG.com
Catalogue No. suffixes for rated control voltages
ORDERING INFORMATION:
Example for Contactor : MN0 Contactor - 240V, 50Hz Example for Spare Coil : MN0 Spare Coil - 360V, 50Hz
Ordering Information - SS94660BOOO Ordering Information - SS94191COOO

AC operation Contactor type

Rated control MM00 MM01 MN0


voltage Us
VAC

Coils at 50 Hz

24 GOOO GOOO GOOO


42 HOOO HOOO HOOO
110 AOOO AOOO AOOO
220 — — KOOO 6
240 BOOO BOOO BOOO
360 — — COOO
415 DOOO DOOO DOOO
525 — — MOOO

DC operation Contactor type

Rated control MM00 MM01 MN0


voltage Us
VDC7

24 4OOO 4OOO 4OOO


42 6OOO 6OOO 6OOO
48 5OOO 5OOO 5OOO
110 1OOO 1OOO 1OOO
220 2OOO 2OOO 2OOO

www.LNTEBG.com 6/15
CONTACTORS - TYPE MR
SINGLE POLE CONTACTORS
Conformance to IS 13947 (Part 4/Sec.1) and IEC:60947-4-1

Contactor Ie Ie Motor rating Built in Qty Wt Catalogue No. *


Type AC-3 AC-1 at 50Hz auxiliary per approx.per
220V 380V 500V contacts Packing Contactor
240V 415V

AC operation

[A] [A] [KW] [KW] [KW] NO NC [No.] [Kg]

6
25 40 3.7 — — — ---- 1 0.25 CS 94052....

MR1

CONTACTORS - TYPE MU
RUGGED POWER CONTACTORS
Conformance to IS 13947 (Part 4/Sec.1) and IEC:60947-4-1

Contactor Ie Ie Motor rating Built in Qty Wt Catalogue No. *


Type AC-3 AC-1 at 50Hz auxiliary per approx.per
220V 380V 500V contacts Packing Contactor
240V 415V

AC operation

[A] [A] [KW] [KW] [KW] NO NC [No.] [Kg]

MU1 16 32 — 10hp — — — 1 0.8 CS94007….

MU2 25 40 — 15hp — — — 1 0.8 CS94008….

* For Voltage suffix refer page 6/7

6/16 www.LNTEBG.com
SPARES

SPARE COILS For Contactor Qty Wt Catalogue No. *


type per approx.per
Packing coil
[No.] [Kg]

AC operation

MU1 / MU2 1 0.15 CS94009

MU1/MU2

Contacts with mounting parts

SPARE KITS For Contactor Qty Wt Catalogue No. *


type per approx.per
Packing coil
[No.] [Kg]

MU1 1 0.05 CS94010

MU2 1 0.05 CS94011

* For voltage suffix refer page 6/11


www.LNTEBG.com 6/17
CONTACTORS - TYPE MC
FOUR POLE CONTACTORS
Conformance to IS 13947 (Part 4/Sec.1) and IEC:60947-4-1

Contactor Ie Ie Motor rating Built in Qty Wt Catalogue No. *


Type AC-3 AC-1 at 50Hz auxiliary per approx.per
220V 380V 500V contacts Packing Contactor
240V 415V

AC operation

[A] [A] 4 NO NC [No.] [Kg]

9 16 7.5 — — 10 0.38 SS94970….


12 25 1) 15 1) — — 10 0.38 SS94971….
6 16 32 20 — — 10 0.38 SS94972….

MC 01/02/03

25 50 30 1 1 1 0.84 CS94047….
1) 1)
35 63 40 1 1 1 0.84 CS94048….

MC 11/12

45 80 50 1 1 1 1.24 SS94977….
1) 1)
65 100 62.5 1 1 1 1.24 SS94978….

MC 21/22

80 130 82.5 1 1 1 3.63 SS94980….


100 160 1) 100 1) 1 1 1 3.63 SS94981….
120 200 125 1 1 1 3.63 SS94982….

MC 31/32/33

185 250 1) 1) 1) - - 1 6.10 ST40095....


320 450 1) 1) 1) - - 1 10.80 ST40096....

MC 88/99

* For Voltage suffix refer page 6/7


1) Data available on request
6/18 www.LNTEBG.com
ACCESSORIES

Auxillary Contact Block Ie AC-15 Ie Auxiliary contact Qty Wt Catalogue No.


at 415V AC-12 combinations

[A] [A] NO NC [No.] [Kg]

1 — 10 0.03 SS94715OOOO
— 1 10 SS94716OOOO
4 10 2 — 10 SS94080OOOO
1 1 10 SS94081OOOO
— 2 10 SS94082OOOO
000000
4 — 10 0.03 SS94083OOOO
3 1 10 SS94084OOOO
4 10 2 2 10 SS94085OOOO
1 3 10 SS94086OOOO
— 4 10 SS94087OOOO 6
1 1 1 0.05 SS94072OOOO
4 10 1 1 1 SS94073OOOO
1 1 1 SS94090OOOO
MC 01, MC02, MC03 1 1 1 SS94092OOOO

Mechanical For Contactor type Qty Wt Catalogue No.


Interlock per approx. per
Packing accessory

MC 01, MC 02, MC 03 MC 01, MC 02, MC 03 5 0.04 SS94071OOOO

MC 11, MC 12 MC 11, MC 12 1 0.4 CS94049OOOO

MC 21, MC 22 MC 21, MC 22 1 0.45 SS94990OOOO

MC 31, MC 32, MC 33 MC 31, MC 32, MC 33 1 2.8 SS94992OOOO

* No Surge Supressor required for MNX 550 Contactor.


1) Provided along with Contactor
2) Additional auxiliary contact block to make 4NO+4NC combination
www.LNTEBG.com 6/19
ACCESSORIES

Auxillary Contact Block Ie AC-15 Ie Auxiliary contact Qty Wt Catalogue No.


at 415V AC-12 combinations

[A] [A] NO NC [No.] [Kg]

4 10 1 1 1 0.01 SS94072OOOO
SS94073OOOO
1 1

_
4 10 1 1 0.01 SS94074OOOO
_
1 SS94075OOOO

MU - A1
6
Mechanical For Contactor type Qty Wt Catalogue No.
Interlock per approx. per
Packing accessory

MU 1, MU 2 MU 1, MU 2 1 0.45 CS94197OOOO

* No Surge Supressor required for MNX 550 Contactor.


1) Provided along with Contactor
2) Additional auxiliary contact block to make 4NO+4NC combination
6/20 www.LNTEBG.com
SPARES

For Contactor Qty Wt Catalogue No. *


SPARE COILS type per approx.per
Packing coil
[No.] [Kg]

AC operation

MC 01/02/03 10 0.09 SS94191...

MC 01/02/03

MC 11/12 10 0.12 CS94009...

6
MC 11/12

MC 21/22 10 0.12 SS94193...

MC 21/22

MC 31/32/33 1 0.20 SS94196...

MC 31/32/33

SPARE KITS Contacts with mounting parts

For Contactor Contents Qty Wt Catalogue No.


type per approx.per
Packing set
[No.] [Kg]

MC 01 Set of 4 moving contacts 25 Sets 0.04 SS 94702OOOO


and 8 fixed contacts with
hardware
MC 02 25 Sets 0.04 SS 94625OOOO

MC 03 25 Sets 0.04 SS 94703OOOO

MC 11 1 Set 0.1 CS 94057OOOO

MC 12 1 Set 0.1 CS 94104OOOO

MC 21 1 Set 0.3 SS 94993OOOO

MC 22 1 Set 0.3 SS 94994OOOO

MC 31 1 Set 0.4 SS 94995OOOO

MC 32 1 Set 0.4 SS 94996OOOO

MC 33 1 Set 0.4 SS 94997OOOO

* For Voltage suffix refer page 6/7


www.LNTEBG.com 6/21
TECHNICAL DATA - TYPE MNX
MNX 9/12/18/25/32 CONTACTORS

MNX 9 MNX 12 MNX 18 MNX 25 MNX 32

Mechanical Life Opns. 15x106 15x106 15x106 10x106 10x106

Rated insulation voltage Ui 690V 690V 690V 690V 690V

Rated impulse withstand Uimp 8KV 8KV 8KV 8KV 8KV

o
Service temperature C -20 to +55 -20 to +55 -20 to +55 -20 to +55 -20 to +55

Utilisation category 3ph,415V,50Hz


AC-1 25A 30A 30A 45A 55A7
AC-2 9A 12A 16A 25A 32A
AC-3 4kw/5.5hp/9A 5.5kw/7.5hp/12A 9.3kw/12.5hp/18A 11kw/15hp/25A 17kw/22.5hp/32A

6 AC-4 4kw/5.5hp/9A 5.5kw/7.5hp/12A 9.3kw/12.5hp/18A 11kw/15hp/25A 17kw/22.5hp/32A

Operational current,Ie, for AC-4


at 415V,50Hz for 200,000 cycles. A 5.5 7.1 8 13.5 16

Making capacity A 450 450 450 480 550

Breaking capacity A 200 250 250 400 500

Capacitor switching delta kVAR 6 7.5 9 15 20


connected,415V,50Hz

Max. frequency Mechanical 7200 7200 7200 7200 7200


of operating AC1 3000 3000 3000 3000 3000
op.cycles/hr AC2 750 750 750 750 750
AC3 750 750 750 750 750
AC4 300 300 300 300 300

Stator duty-415V,50Hz - Duty factor -


20% 14.5A 18A 24A 38A 48A
40% 14.5A 18A 24A 38A 48A
60% 11A 15A 20A 31A 40A

Rotor duty-delta connected-Duty factor -


20% 22A 27A 36A 57A 72A
40% 22A 27A 36A 57A 72A
60% 16A 22A 30A 46A 66A

Main terminal capacity Lug(mm2) 1x6 1x6 1x6 1x10 1x10


Wires(mm2) 2x4 2x4 2x4 2x6 2x6

Aux.terminal capacity
Wires(mm2) 2x2.5 2x2.5 2x2.5 — —

Pick up time msec 10-12 10-12 10-12 10-12 10-12

Drop off time msec 7-18 7-18 7-18 7-18 7-18

Operating limits (%Uc) 80-110 80-110 80-110 80-110 80-110

Coil Consumption at 50Hz


Pick-up VA 68 68 68 100 100

Hold-on VA 11 11 11 15 15

6/22 www.LNTEBG.com
TECHNICAL DATA - TYPE MNX
MNX 45/50/70/80 CONTACTORS

MNX 45 MNX 50 MNX 70 MNX 80

Mechanical Life Opns. 10x106 10x106 10x106 10x106

Rated insulation voltage Ui 690V 690V 690V 690V

Rated impulse withstand Uimp 8KV 8KV 8KV 8KV

o
Service temperature C -20 to +55 -20 to +55 -20 to +55 -20 to +55

Utilisation category 3ph,415V,50Hz


AC-1 80A 80A 100A 100A
AC-2 45A 50A 70A 80A
AC-3 25kw/34hp/45A 26kw/35hp/50A 37kw/50hp/70A 40kw/54hp/80A
AC-4 25kw/34hp/45A 26kw/35hp/50A 30kw/40hp/63A 37kw/50hp/70A
6
Operational current,Ie, for AC-4
at 415V,50Hz for 200,000 cycles. A 24 24 28.5 43

Making capacity A 900 900 900 900

Breaking capacity A 750 750 750 750

Capacitor switching delta kVAR 30 30 35 40


connected,415V,50Hz

Max. frequency Mechanical 3600 3600 3600 3600


of operating AC1 3000 3000 3000 3000
op.cycles/hr AC2 750 750 750 750
AC3 750 750 750 750
AC4 300 300 300 300

Stator duty-415V,50Hz - Duty factor -


20% 68A 98A
40% 68A 98A — —
60% 56A 81A

Rotor duty-delta connected-Duty factor -


20% 102A 147A
40% 102A 147A — —
60% 84A 121A

Main terminal capacity Lug(mm2) 1x35 1x35 1x35 1x35


Wires(mm2) — — — —z

Aux.terminal capacity
Wires(mm2) 2x2.5 2x2.5 2x2.5 2x2.5

Pick up time msec 15-35 15-35 15-35 15-35

Drop off time msec 10-25 10-25 10-25 10-25

Operating limits (%Uc) 80-110 80-110 80-110 80-110

Coil Consumption at 50Hz


Pick-up VA 190 190 190 190
Hold-on VA 21 21 21 21

www.LNTEBG.com 6/23
TECHNICAL DATA - TYPE MNX
MNX 95/110/140 CONTACTORS

MNX 95 MNX 110 MNX 140

Mechanical Life Opns. 10x106 10x106 10x106

Rated insulation voltage Ui 1000V 1000V 1000V

Rated impulse withstand Uimp 8KV 8KV 8KV

o
Service temperature C -20 to +55 -20 to +55 -20 to +55

Utilisation category 3ph,415V,50Hz


AC-1 160A 160A 160A
AC-2 95A 110A 140A
AC-3 45kw/60hp/95A 55kw/75hp/110A 75kw/100hp/140A

6 AC-4 45kw/60hp/95A 55kw/75hp/110A 75kw/100hp/140A

Operational current,Ie, for AC-4


at 415V,50Hz for 200,000 cycles. A 53 58 66

Making capacity A 1680 1680 1800

Breaking capacity A 1400 1400 1600

Capacitor switching delta kVAR 65 65 70


connected,415V,50Hz

Max. frequency Mechanical 3600 3600 3600


of operating AC1 3000 3000 3000
op.cycles/hr AC2 750 750 750
AC3 750 750 750
AC4 300 300 300

Stator duty-415V,50Hz - Duty factor -


20% 143A 165A 210A
40% 143A 165A 210A
60% 120A 135A 175A

Rotor duty-delta connected-Duty factor -


20% 214A 250A 315A
40% 214A 250A 315A
60% 180A 203A 262A

Main terminal capacity Lug(mm2) 1x120 1x120 1x120


Wires(mm2) — — —

Aux.terminal capacity
Wires(mm2) 2x2.5 2x2.5 2x2.5

Pick up time msec 20-40 20-40 20-40

Drop off time msec 10-25 10-25 10-25

Operating limits (%Uc) 80-110 80-110 80-110

Coil Consumption at 50Hz


Pick-up VA 550 550 550
Hold-on VA 36 36 36

6/24 www.LNTEBG.com
TECHNICAL DATA - TYPE MNX
MNX 185/225 CONTACTORS

MNX 185 MNX 225

Mechanical Life Opns. 10x106 10x106

Rated insulation voltage Ui 1000 V 1000 V

Rated impulse withstand Uimp 8KV 8KV

Service temperature oC -20 to +55 -20 to +55

Utilisation category 3ph,415V,50Hz


AC-1 250A 300A
AC-2 185 A 225 A
AC-3 90kw/125 hp/185A 110kw/150hp/225A
AC-4 90kw/125 hp/160 A 100kw/136hp/200 A
6
Operational current,Ie, for AC-4
at 415V,50Hz for 200,000 cycles. A 90 100

Making capacity 2220 2400

Breaking capacity 1850 2000

Capacitor switching delta


connected,415V,50Hz kVAR 100 125

Max. frequency Mechanical 3600 3600


of operating AC1 3000 3000
op.cycles/hr AC2 750 750
AC3 750 750
AC4 250 250

Stator duty-415V,50Hz - Duty factor -


20%
40% 1) 1)

60%

Rotor duty-delta connected-Duty factor -


20%
40% 1) 1)

60%

Main terminal capacity Lug(mm2) 1x185 1x185


Wires(mm2) — —

Aux.terminal capacity
Wires(mm2) 2 x 2.5 2 x 2.5

Pick up time msec 20-45 20-45

Drop off time msec 10-25 10-25

Operating limits (%Uc) 80-110 80-110

Coil Consumption at 50Hz


Pick-up VA 960 960
Hold-on VA 56 56

Note : 1) Data available on request.


www.LNTEBG.com 6/25
TECHNICAL DATA - TYPE MNX
MNX 265/325/400/550 CONTACTORS

MNX 265 MNX 325 MNX 400 MNX 550

Mechanical Life Opns. 10x106 10x106 10x106 10x106

Rated insulation voltage Ui 1000V 1000V 1000V 1000V

Rated impulse withstand Uimp 8KV 8KV 8KV 8KV

o
Service temperature C -20 to +55 -20 to +55 -20 to +55 -5 to +55

Utilisation category 3ph,415V,50Hz


AC-1 350A 400A 425A 650A
AC-2 265A 325A 400A 550A
AC-3 147kw/265A 180kw/245hp/325A 200kw/270hp/400A 315kw/425hp/ 550A

6 AC-4 130kw/175hp/235A 140kw/190hp/250A 150kw/200hp/275A 200kw/270hp/550A

Operational current,Ie, for AC-4


at 415V,50Hz for 200,000 cycles. A 120 140 150 150

Making capacity A 4000 4500 4500 5500

Breaking capacity A 3200 4000 4000 4500

Capacitor switching delta kVAR 150 175 175 250


connected,415V,50Hz

Max. frequency Mechanical 3600 3600 3600 1200


of operating AC1 3000 3000 3000 750
op.cycles/hr AC2 750 750 750 750
AC3 750 750 750 150
AC4 150 150 150 150

Stator duty-415V,50Hz - Duty factor -


20% 332A 407A 500A
40% 332A 407A 500A 1)

60% 282A 340A 425A

Rotor duty-delta connected-Duty factor -


20% 498A 610A 750A
40% 498A 610A 750A 1)

60% 423A 510A 635A

Main terminal capacity Lug(mm2) 2x240/1x300 2x240/1x300 2x240/1x300 2x240/1x300


Wires(mm2) — — — —

Aux.terminal capacity
Wires(mm2) 2x2.5 2x2.5 2x2.5 2x2.5

Pick up time msec 20-45 20-45 20-45 50-60

Drop off time msec 10-25 10-25 10-25 150-170

Operating limits (%Uc) 80-110 80-110 80-110 80-110

Coil Consumption at 50Hz


Pick-up VA 2100 2100 2100 1000
Hold-on VA 95 95 95 25
Note : 1) Data available on request.
6/26 www.LNTEBG.com
TECHNICAL DATA - TYPE MN (WIDE - BAND)
MN 9W/12W/16W/25W CONTACTORS

MN 9W MN 12W MN 16W MN 25W

Mechanical Life Opns. 10x106 10x106 10x106 10x106

Rated insulation voltage Ui 690V 690V 690V 690V

Rated impulse withstand Uimp 8KV 8KV 8KV 8KV

o
Service temperature C -20 to +55 -20 to +55 -20 to +55 -20 to +55

Utilisation category 3ph,415V,50Hz


AC-1 25A 30A 30A 45A
AC-2 9A 12A 16A 25A
AC-3 4kw/5.5hp/9A 5.5kw/7.5hp/12A 7.5kw/10hp/16A 11kw/15hp/25A
AC-4 4kw/5.5hp/9A 5.5kw/7.5hp/12A 7.5kw/10hp/16A 11kw/15hp/25A 6
Making capacity A 450 450 450 480

Breaking capacity A 200 250 250 400

Capacitor switching delta kVAR 6 7.5 9 15


connected,415V,50Hz

Max. frequency Mechanical 7200 7200 7200 7200


of operating AC1 3000 3000 3000 3000
op.cycles/hr AC2 750 750 750 750
AC3 750 750 750 750
AC4 300 300 300 300

Stator duty-415V,50Hz - Duty factor -


20% 14.5A 18A 24A 38A
40% 14.5A 18A 24A 38A
60% 11A 15A 20A 31A

Rotor duty-delta connected-Duty factor -


20% 22A 27A 36A 57A
40% 22A 27A 36A 57A
60% 16A 22A 30A 46A

Main terminal capacity Lug(mm2) 1x6 1x6 1x6 1x10


Wires(mm2) 2x2.5 2x2.5 2x2.5 2x4

Aux.terminal capacity
Wires(mm2) 2x2.5 2x2.5 2x2.5 2x2.5

Pick up time msec 10-22 10-22 10-22 13-25

Drop off time msec 7-18 7-18 7-18 8-18

Operating limits (%Uc) 55-110 55-110 55-110 55-110

Coil Consumption at 50Hz


Pick-up VA 68 68 68 100
Hold-on VA 11 11 11 15

www.LNTEBG.com 6/27
TECHNICAL DATA - TYPE MN (CAPACITOR DUTY)
MN 16C/32C CONTACTORS

MN 16C MN 32C

Mechanical Life Opns. 10x106 10x106

Rated insulation voltage Ui 690V 690V

Rated impulse withstand Uimp 8KV 8KV

o
Service temperature C -20 to +55 -20 to +55

Utilisation category 3ph,415V,50Hz AC-6b 10kVAR 25kVAR

Operating limits (% Uc) 80-110 80-110

Coil Consumption at 50 Hz pick-up VA 68 100


6
Coil Consumption at 50 Hz hold-on VA 11 15

6/28 www.LNTEBG.com
TECHNICAL DATA - TYPE ML
ML0/1/1.5/2/3 CONTACTORS

ML0 ML1 ML1.5 ML2 ML3

Mechanical Life Opns. 15x106 15x106 15x106 10x106 10x106

Rated insulation voltage Ui 500V 500V 500V 500V 500V

Rated impulse withstand Uimp 8KV 8KV 8KV 8KV 8KV

o
Service temperature C -20 to +55 -20 to +55 -20 to +55 -20 to +55 -20 to +55

Utilisation category 3ph,415V,50Hz


AC-1 16A 25A 25A 40A 45A
AC-2 12A 16A 25A 32A 40A
AC-3 5.5kw/7.5hp/12A 7.5kw/10hp/16A 11kw/15hp/25A 15kw/20hp/32A 22kw/30hp/40A
AC-4 4.5kw/6hp/10A 7.5Kw/10hp/16A 9kw/12.5hp/21A 15kw/20hp/32A 22kw/30hp/40A
6
Operational current,Ie, for AC-4
at 415V,50Hz for 300,000 cycles. A 6.3 10 13.5 17 22

Making capacity A 120 192 252 400 480

Breaking capacity A 100 160 210 320 400

Capacitor switching delta kVAR 3 8 13 20 20


connected,415V,50Hz

Max. frequency Mechanical 3000 3000 3000 2000 2000


of operating AC1 3000 3000 3000 750 750
op.cycles/hr AC2 750 750 750 750 750
AC3 750 750 750 750 750
AC4 250 250 250 250 250

Stator duty-415V,50Hz - Duty factor -


20% 15.5A 24A 37A 48A 60A
40% 15.5A 24A 37A 48A 60A
60% 12.5A 20A 30A 40A 50A

Rotor duty-delta connected-Duty factor -


20% 23A 36A 56A 72A 90A
40% 23A 36A 56A 72A 90A
60% 19A 30A 44A 60A 75A

Main terminal capacitY Lug(mm2) 16 16 16 50 50


Wires(mm2) 2x10 2x10 2x10 2x25 2x25

Aux.terminal capacity
Wires(mm2) 2x2.5 2x2.5 2x2.5 2x2.5 2x2.5

Pick up time msec 5-35 5-35 5-35 10-35 10-35

Drop off time msec 5-20 5-20 5-20 5-25 5-25

Operating limits (%Uc) 80-110 80-110 80-110 80-110 80-110

Coil Consumption at 50Hz


Pick-up VA 60 60 60 120 120
Hold-on VA 15 15 15 20 20

www.LNTEBG.com 6/29
TECHNICAL DATA - TYPE ML
ML4/6/10/12 CONTACTORS

ML4 ML6 ML10 ML12

Mechanical Life Opns. 10x106 10x106 10x106 10x106

Rated insulation voltage Ui 660V 660V 660V 660V

Rated impulse withstand Uimp 8KV 8KV 8KV 8KV

o
Service temperature C -20 to +55 -20 to +55 -20 to +55 -20 to +55

Utilisation category 3ph,415V,50Hz


AC-1 100A 125A 250A 400A
AC-2 70A 110A 200A 300A
AC-3 37kw/50hp/70A 55kw/75hp/110A 110kw/150hp/200A 168kw/225hp/300A

6 AC-4 37kw/50hp/70A 45kw/60hp/85A 110kw/150hp/200A 140kw/190hp/250A

Operational current,Ie, for AC-4


at 415V,50Hz for 300,000 cycles. A 35 46 90 112

Making capacity A 840 1200 2500 3000

Breaking capacity A 700 1000 2000 2500

Capacitor switching delta kVAR 50 65 125 175


connected,415V,50Hz

Max. frequency Mechanical 1200 1200 1200 1200


of operating AC1 1000 750 750 750
op.cycles/hr AC2 500 500 500 500
AC3 750 750 500 500
AC4 250 250 250 250

Stator duty-415V,50Hz - Duty factor -


20% 95A 165A 250A 375A
40% 95A 165A 250A 375A
60% 78A 135A 206A 310A

Rotor duty-delta connected-Duty factor -


20% 157A 270A 370A 560A
40% 157A 270A 370A 560A
60% 118A 206A 310A 465A

Main terminal capacity Lug(mm2) 50 95 240 240


Wires(mm2) — — — —

Aux.terminal capacity
Wires(mm2) 2x2.5 2x2.5 2x2.5 2x2.5

Pick up time msec 10-35 10-35 15-45 15-45

Drop off time msec 10-40 10-40 5-25 5-25

Operating limits (%Uc) 80-110 80-110 80-110 80-110

Coil Consumption at 50Hz


Pick-up VA 450 450 1450 1450
Hold-on VA 50 50 85 85

6/30 www.LNTEBG.com
TECHNICAL DATA - TYPE MM
MM CONTACTORS

MM00-AC MM01-AC MM00-DC MM01-DC

Mechanical Life Opns. 10x106 10x106 10x106 10x106

Rated insulation voltage Ui 690V 690V 690V 690V

Rated impulse withstand Uimp 8KV 8KV 8KV 8KV

o
Service temperature C -20 to +55 -20 to +55 -20 to +55 -20 to +55

Utilisation category 3ph,415V,50Hz


AC-1 10A 10A 10A 10A
AC-15 4A 4A 4A 4A

Main terminal capacity Lug(mm2)


Wires(mm2) 2x2.5 2x2.5 2x2.5 2x2.5
6
Operating limits (%Uc) 80-110 80-110 80-110 80-110

Coil Consumption at 50Hz


Pick-up 85VA 85VA 8W 8W
Hold-on 16VA 16VA — —

www.LNTEBG.com 6/31
TECHNICAL DATA - TYPE MN
MN 0 CONTACTORS

MN0 ac MN0 dc

Mechanical Life Opns. 10x106 10x106

Rated insulation voltage, Ui 690V 690V

Rated impulse withstand, Uimp 8KV 8KV

o
Service temperature C -20 to +55 -20 to +55

Utilisation category 3ph,415V,50Hz


AC-1 10A 10A
AC-15 4A 4A

Operating limits (% Uc) 80-110 80-110


6 Coil Consumption at 50 Hz
pick-up 68VA 8W
hold-on 11VA 8W

6/32 www.LNTEBG.com
TECHNICAL DATA - TYPE MU
MU1/2 CONTACTORS

MU1 MU2

Mechanical Life Opns. 10x106 10x106

Rated insulation voltage Ui 690V 690V

Rated impulse withstand Uimp — —

o
Service temperature C -5 to + 55 -5 to + 55

Utilisation category 3ph, 415V, 50Hz


AC-1 32A 40A
AC-2 16A 25A
AC-3 7.5kw/10hp/16A 11kw/15hp/25A
AC-4 16A 25A
6
Operational current, Ie, for AC-4
at 415V, 50Hz for 200,000 cycles. A 12A 16A

Making capacity A 192 300

Breaking capacity A 160 250

Capacitor switching delta kVAR 7.5 9


connected, 415V, 50Hz

Max. frequency Mechanical 7200 7200


of operating AC1 3000 3000
op.cycles/hr AC2 750 750
AC3 750 750
AC4 300 300

Stator duty-415V, 50Hz - Duty factor -


20% 24A 38A
40% 24A 38A
60% 20A 31A

Rotor duty-delta connected-Duty factor -


20% 36A 57A
40% 36A 57A
60% 30A 46A

Main terminal capacity Lug(mm2) 16 16


Wires(mm2) 2x10 2x10

Aux.terminal capacity
Wires(mm2) — —

Pick up time msec 10-25 10-25

Drop off time msec 9-21 9-21

Operating limits (%Uc) 50-110 50-110

Coil Consumption at 50Hz


Pick-up VA 180 180

Hold-on VA 22 22

www.LNTEBG.com 6/33
TECHNICAL DATA - TYPE MC
MC 01/02/03/11/12 CONTACTORS

MC01 MC02 MC03 MC11 MC12

Mechanical Life Opns. 15x106 15x106 15x106 15x106 15x106

Rated insulation voltage Ui 690V 690V 690V 690V 690V

Rated impulse withstand Uimp 8KV 8KV 8KV 8KV 8KV

o
Service temperature C -20o to 55o -20o to 55o -20o to 55o -20o to 55o -20o to 55o

Utilisation category 3ph, 415V, 50Hz


AC-1 16A 25A 32A 50A 63A
AC-2 _ _ _ _ _

AC-3 9A 12A 16A 25A 35A


_ _ _ _ _
6 AC-4

Operational current,Ie, for AC-4 * * * * *


at 415V, 50Hz for 200,000 cycles. A

Making capacity A 10Xle (AC-3)

Breaking capacity A 10Xle (AC-3)

Capacitor switching delta kVAR _ _ _ _ _

connected, 415V, 50Hz

Max. frequency Mechanical 7200 7200 7200 7200 7200


of operating AC1 3000 3000 3000 3000 3000
op.cycles/hr
AC3 750 750 750 750 750

Stator duty-415V, 50Hz - Duty factor -


20%
40% * * * * *
60%

Rotor duty-delta connected-Duty factor -


20%
40% * * * * *
60%

Main terminal capacity Lug(mm2) 1x6 1x6 1x16 1x16 1x16


Wires(mm2)

Aux.terminal capacity _ _ _ _ _
Wires(mm2)

Pick up time msec 10-22 10-22 10-25 10-25 10-25

Drop off time msec 7-18 7-18 7-18 9-21 9-21

Operating limits (%Uc) 80-110 80-110 80-110 80-110 80-110

Coil Consumption at 50Hz


Pick-up VA 68 68 180 180 180

Hold-on VA 11 11 22 22 22

* Data available on request


6/34 www.LNTEBG.com
TECHNICAL DATA - TYPE MC
MC 21/22/31/32/33 CONTACTORS

MC21 MC22 MC31 MC32 MC33

Mechanical Life Opns. 10x106 10x106 10x106 10x106 10x106

Rated insulation voltage Ui 690V 690V 690V 690V 690V

Rated impulse withstand Uimp 8KV 8KV 8KV 8KV 8KV

o
Service temperature C -20o to 55o -20o to 55o -20o to 55o -20o to 55o -20o to 55o

Utilisation category 3ph, 415V, 50Hz


AC-1 80A 100A 130A 160A 200A
AC-2 _ _ _ _ _

AC-3 45A 65A 80A 100A 120A


_ _ _ _ _
AC-4
6
Operational current,Ie, for AC-4 * * * * *
at 415V, 50Hz for 200,000 cycles. A

Making capacity A 10Xle (AC-3)

Breaking capacity A 10Xle (AC-3)

Capacitor switching delta kVAR _ _ _ _ _

connected, 415V, 50Hz

Max. frequency Mechanical 7200 7200 2400 2400 2400


of operating AC1 3000 3000 2400 2400 2400
op.cycles/hr
AC3 750 750 750 750 750

Stator duty-415V, 50Hz - Duty factor -


20%
40% * * * * *
60%

Rotor duty-delta connected-Duty factor -


20%
40% * * * * *
60%

Main terminal capacity Lug(mm2) 1x35 1x35 1x120 1x120 1x120


Wires(mm2)

Aux.terminal capacity _ _ _ _ _
Wires(mm2)

Pick up time msec 15-35 15-35 20-40 20-40 20-40

Drop off time msec 10-25 10-25 10-25 10-25 10-25

Operating limits (%Uc) 80-110 80-110 80-110 80-110 80-110

Coil Consumption at 50Hz


Pick-up VA 190 190 550 550 550

Hold-on VA 22 22 36 36 36

* Data available on request


www.LNTEBG.com 6/35
TECHNICAL DATA - SINGLE POLE
MR1 CONTACTORS

MR1

Mechanical Life Opns. 10x106

Rated insulation voltage Ui 690V

Rated impulse withstand Uimp 8KV

o
Service temperature C -5 to 55

Utilisation category 3ph,415V,50Hz


AC-1 40A
AC-2 3.7kw, 5hp, 25A
AC-3 3.7kw, 5hp, 25A

6 AC-4 3.7kw, 5hp, 25A

Operational current,Ie, for AC-4


at 415V,50Hz for 200,000 cycles. A 12

Making capacity A 250

Breaking capacity A 200

Capacitor switching delta kVAR 15


connected,415V,50Hz

Max. frequency Mechanical 7200


of operating AC1 3000
op.cycles/hr AC2 750
AC3 750
AC4 300

Stator duty-415V,50Hz - Duty factor -


20% 38A
40% 38A
60% 31A

Rotor duty-delta connected-Duty factor -


20% 57A
40% 57A
60% 46A

Main terminal capacity Lug(mm2) 1x10


Wires(mm2) 2x10

Aux.terminal capacity —
Wires(mm2)

Pick up time msec 13-25

Drop off time msec 6-15

Operating limits (%Uc) 85-110

Coil Consumption at 50Hz


Pick-up VA 50

Hold-on VA 9

6/36 www.LNTEBG.com
ELECTRICAL LIFE CURVES - TYPE MNX
MNX CONTACTORS

UTILISATION CATEGORY AC-1

UTILISATION CATEGORY AC-2

www.LNTEBG.com 6/37
ELECTRICAL LIFE CURVES - TYPE MNX
MNX CONTACTORS

UTILISATION CATEGORY AC-3

UTILISATION CATEGORY AC-4

6/38 www.LNTEBG.com
ELECTRICAL LIFE CURVES - TYPE ML
ML CONTACTORS

UTILISATION CATEGORY AC-1

UTILISATION CATEGORY AC-2

www.LNTEBG.com 6/39
ELECTRICAL LIFE CURVES - TYPE ML
ML CONTACTORS

UTILISATION CATEGORY AC-3

UTILISATION CATEGORY AC-4

6/40 www.LNTEBG.com
TERMINAL ARRANGEMENTS - TYPE MNX
POWER CONTACTORS

Note: For ML, MC, MU and MR contactors the terminal arrangements available on request.
www.LNTEBG.com 6/41
TERMINAL ARRANGEMENTS - TYPE MN
CAPACITOR CONTACTORS

AUXILIARY CONTACT BLOCKS - TYPE MNX A1

Note: For MNX-A33S-2 and MNX-A46S-2 auxiliary contact block terminal arrangements refer page 6/31 shown adjacent to contactor terminal
adjustments.
i.e. for 1NO+1NC left - 13, 21, 22, 14
1NO+1NC right - 43, 31, 32, 44
1NO+1NC second left - 53, 61, 62, 54
1NO+1NC second right- 83, 71, 72, 84
6/42 www.LNTEBG.com
TERMINAL ARRANGEMENTS
CONTROL CONTACTORS

MN0/MN0DC-40E

MN0/MN0DC-22E

Note: For control contactors MM00 and MM01 (AC/DC) terminal arrangements available on request.
www.LNTEBG.com 6/43
OVERALL DIMENSIONS
MNX 9, 12, 18 CONTACTORS

MNX 25, 32 CONTACTORS

Note: All dimensions are in mm.


6/44 www.LNTEBG.com
OVERALL DIMENSIONS
MNX 45, MNX 50, MNX 70, MNX 80 CONTACTORS

MNX 95, MNX 110, MNX 140 CONTACTORS

Note: All dimensions are in mm.


www.LNTEBG.com 6/45
OVERALL DIMENSIONS
MNX 185, MNX 225 CONTACTORS

MNX 265, MNX 325, MNX 400, MNX 550 CONTACTORS

Note: All dimensions are in mm.


6/46 www.LNTEBG.com
OVERALL DIMENSIONS
MU 1, MU 2 CONTACTORS

Note: All dimensions are in mm.


www.LNTEBG.com 6/47
OVERALL DIMENSIONS
MN 16C CONTACTORS

MN 32C CONTACTORS

Note: All dimensions are in mm.


6/48 www.LNTEBG.com
OVERALL DIMENSIONS
MN 0 dc, MN 16 dc CONTACTORS

50
147

136

120

99.7
6

10
2

35
60-70 45
81

POSIBILITY OF MOUNTING ON
TH35-7.5 RAIL AS PER IS : 11039

MN 0 ac CONTACTORS

52
113

102

86

65
6

65-70 35
2

81 45

Note: All dimensions are in mm.


www.LNTEBG.com 6/49
OVERALL DIMENSIONS
ML0, ML1, ML1.5 CONTACTORS

ML2, ML3 CONTACTORS

Note: All dimensions are in mm.


6/50 www.LNTEBG.com
OVERALL DIMENSIONS
ML4 CONTACTORS

ML6 CONTACTORS

* Provide 12 mm extra for each Add-on block

Note: All dimensions are in mm.


www.LNTEBG.com 6/51
OVERALL DIMENSIONS
ML10, ML12 CONTACTORS

MM00 CONTACTORS

Note: All dimensions are in mm.


6/52 www.LNTEBG.com
OVERALL DIMENSIONS
MM01 CONTACTORS

MM0 odc CONTACTORS

Note: All dimensions are in mm.


www.LNTEBG.com 6/53
OVERALL DIMENSIONS
MC 01, MC 02, MC 03 CONTACTORS

MC 11, MC 12 CONTACTORS

Note: All dimensions are in mm.


6/54 www.LNTEBG.com
OVERALL DIMENSIONS
MC 21, MC 22 CONTACTORS

MC 31, MC 32, MC 33 CONTACTORS

Note: All dimensions are in mm.


www.LNTEBG.com 6/55
OVERALL DIMENSIONS
MR 1 CONTACTORS

Note: All dimensions are in mm.


6/56 www.LNTEBG.com
OVERALL DIMENSIONS
MN 9W, MN 12W, MN 16W CONTACTORS

MN 25W CONTACTORS

Note: All dimensions are in mm.


www.LNTEBG.com 6/57