0% found this document useful (0 votes)
31 views5 pages

Other Rooms Are Symetricall, Shown in The Framing Plan

The document contains details of 33 rooms across two floors of a building including each room's dimensions, floor height, load details from tiles, ceilings, waterproofing and utilities. It also includes specifications for interior and exterior partitions including thickness, span ratios and load capacities in both short and long spans.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
31 views5 pages

Other Rooms Are Symetricall, Shown in The Framing Plan

The document contains details of 33 rooms across two floors of a building including each room's dimensions, floor height, load details from tiles, ceilings, waterproofing and utilities. It also includes specifications for interior and exterior partitions including thickness, span ratios and load capacities in both short and long spans.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 5

ROOM LENGTH(LONG),m WIDTH(SHORT),m FLOOR HEIGHT

ROOM 1 5.31 4.90 3


ROOM 2 4.11 4.90 3
ROOM 3 4.11 3.90 3
ROOM 4 4.18 3.90 3
ROOM 5 4.90 3.90 3
ROOM 6 4.90 3.90 3
ROOM 7 5.13 3.90 3
ROOM 8 4.11 3.90 3
ROOM 9 3.90 3.90 3
ROOM 10 3.90 3.90 3
ROOM 11 3.90 3.90 3
ROOM 12 3.90 3.90 3
ROOM 13 5.13 2.80 3
ROOM 14 4.11 2.80 3
ROOM 15 3.90 2.80 3
1ST FLOOR

ROOM 16 3.90 2.80 3


ROOM 17 3.90 2.80 3
ROOM 18 3.90 2.80 3
ROOM 19 5.13 3.90 3
ROOM 20 4.11 3.90 3
ROOM 21 3.90 3.90 3
ROOM 22 3.90 3.90 3
ROOM 23 3.90 3.90 3
ROOM 24 3.90 3.90 3
ROOM 25 5.13 4.90 3
ROOM 26 4.90 4.11 3
ROOM 27 4.18 3.90 3
ROOM 28 4.18 3.90 3
ROOM 29 4.90 3.90 3
ROOM 30 4.90 3.90 3
ROOM 31 8.11 4.02 3
ROOM 32 8.11 3.90 3
ROOM 33 8.11 2.80 3
OTHER ROOMS ARE SYMETRICALL, SHOWN IN THE FRAMING PLAN
TILES; KPa CEILING; Kpa WATER PROOFING UTILITIES; Kpa TOTAL SUPERIMPOSED
1.1 0.18 0.15 0.4 1.83
1.1 0.18 0.15 0.4 1.83
1.1 0.18 0.15 0.4 1.83
1.1 0.18 0.15 0.4 1.83
1.1 0.18 0.15 0.4 1.83
1.1 0.18 0.15 0.4 1.83
1.1 0.18 0.15 0.4 1.83
1.1 0.18 0.15 0.4 1.83
1.1 0.18 0.15 0.4 1.83
1.1 0.18 0.15 0.4 1.83
1.1 0.18 0.15 0.4 1.83
1.1 0.18 0.15 0.4 1.83
1.1 0.18 0.15 0.4 1.83
1.1 0.18 0.15 0.4 1.83
1.1 0.18 0.15 0.4 1.83
1.1 0.18 0.15 0.4 1.83
1.1 0.18 0.15 0.4 1.83
1.1 0.18 0.15 0.4 1.83
1.1 0.18 0.15 0.4 1.83
1.1 0.18 0.15 0.4 1.83
1.1 0.18 0.15 0.4 1.83
1.1 0.18 0.15 0.4 1.83
1.1 0.18 0.15 0.4 1.83
1.1 0.18 0.15 0.4 1.83
1.1 0.18 0.15 0.4 1.83
1.1 0.18 0.15 0.4 1.83
1.1 0.18 0.15 0.4 1.83
1.1 0.18 0.15 0.4 1.83
1.1 0.18 0.15 0.4 1.83
1.1 0.18 0.15 0.4 1.83
1.1 0.18 0.15 0.4 1.83
1.1 0.18 0.15 0.4 1.83
1.1 0.18 0.15 0.4 1.83
PRESSURE FOR 100mm THK CHB IS PLACED UNDER THE PARTITIONS
PARTITIONS
M=L/W SHORT SPAN,Kn/m LONG SPAN,Kn/m
INTERIOR CHB ; 150mm EXTERIOR CHB; 100mm
2.4 1.76 0.92 2.99 3.48
2.4 1.76 1.19 2.99 1.98
2.4 1.76 0.95 2.38 2.63
2.4 1.76 0.93 2.38 2.71
2.4 1.76 0.80 2.38 3.54
2.4 1.76 0.80 2.38 3.54
2.4 1.76 0.76 2.38 3.79
2.4 1.76 0.95 2.38 2.63
2.4 1.76 1.00 2.38 2.38
2.4 1.76 1.00 2.38 2.38
2.4 1.76 1.00 2.38 2.38
2.4 1.76 1.00 2.38 2.38
2.4 1.76 0.55 1.71 4.23
2.4 1.76 0.68 1.71 3.18
2.4 1.76 0.72 1.71 2.96
2.4 1.76 0.72 1.71 2.96
2.4 1.76 0.72 1.71 2.96
2.4 1.76 0.72 1.71 2.96
2.4 1.76 0.76 2.38 3.79
2.4 1.76 0.95 2.38 2.63
2.4 1.76 1.00 2.38 2.38
2.4 1.76 1.00 2.38 2.38
2.4 1.76 1.00 2.38 2.38
2.4 1.76 1.00 2.38 2.38
2.4 1.76 0.96 2.99 3.27
2.4 1.76 0.84 2.51 3.43
2.4 1.76 0.93 2.38 2.71
2.4 1.76 0.93 2.38 2.71
2.4 1.76 0.80 2.38 3.54
2.4 1.76 0.80 2.38 3.54
2.4 1.76 0.50 2.45 6.81
2.4 1.76 0.48 2.38 6.85
2.4 1.76 0.35 1.71 7.13
INTERIOR EXTERIOR INT. + EXT. + SHORT, EXT. + LONG,
INT. + LONG, Kn/m
LD,Kn/m LD,Kn/m SHORT,Kn/m Kn/m Kn/m
7.2 5.28 10.19 10.68 8.27 8.76
7.2 5.28 10.19 9.18 8.27 7.26
7.2 5.28 9.58 9.83 7.66 7.91
7.2 5.28 9.58 9.91 7.66 7.99
7.2 5.28 9.58 10.74 7.66 8.82
7.2 5.28 9.58 10.74 7.66 8.82
7.2 5.28 9.58 10.99 7.66 9.07
7.2 5.28 9.58 9.83 7.66 7.91
7.2 5.28 9.58 9.58 7.66 7.66
7.2 5.28 9.58 9.58 7.66 7.66
7.2 5.28 9.58 9.58 7.66 7.66
7.2 5.28 9.58 9.58 7.66 7.66
7.2 5.28 8.91 11.43 6.99 9.51
7.2 5.28 8.91 10.38 6.99 8.46
7.2 5.28 8.91 10.16 6.99 8.24
7.2 5.28 8.91 10.16 6.99 8.24
7.2 5.28 8.91 10.16 6.99 8.24
7.2 5.28 8.91 10.16 6.99 8.24
7.2 5.28 9.58 10.99 7.66 9.07
7.2 5.28 9.58 9.83 7.66 7.91
7.2 5.28 9.58 9.58 7.66 7.66
7.2 5.28 9.58 9.58 7.66 7.66
7.2 5.28 9.58 9.58 7.66 7.66
7.2 5.28 9.58 9.58 7.66 7.66
7.2 5.28 10.19 10.47 8.27 8.55
7.2 5.28 9.71 10.63 7.79 8.71
7.2 5.28 9.58 9.91 7.66 7.99
7.2 5.28 9.58 9.91 7.66 7.99
7.2 5.28 9.58 10.74 7.66 8.82
7.2 5.28 9.58 10.74 7.66 8.82
7.2 5.28 9.65 14.01 7.73 12.09
7.2 5.28 9.58 14.05 7.66 12.13
7.2 5.28 8.91 14.33 6.99 12.41
LOADINGS OF EACH SIDE PER ROOM