RV Series Pressure Relief Valves: Key Features

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

RV Series Pressure

F LOW C O N T R O L VA LV ES
Relief Valves
1/2" TO 2" PVC and CPVC

KEy FEaTurEs
• PVC and CPVC
• Hand Adjustable, No Tools Needed
• Integrally Molded Threaded Gauge Port
• Pressure Relief from 5 PSI to 75 PSI
OPTiOns
• 0 to 30 PSI Gauge
• 0 to 60 PSI Gauge
• 0 to 160 PSI Gauge
• Gauge Guards
• 2 to 20 PSI for 1-1/2" to 2" with
Low Pressure Spring
• Flanged Ends
maTEriaLs
• PVC Cell Class 12454 per ASTM D1784
• CPVC Cell Class 23447 per ASTM D1784
• FPM and EPDM O-Ring Seals

technical inFormation

sELECTiOn CHarT
End sEaLs PrEssurE PrEssurE
sizE maTEriaL COnnECTiOn sETTinG raTinG

PVC or Threaded or FPM 150 PSI


1/2" – 2" or 5 to 75* PSI @ 70°F
(DN15 – DN50) CPVC Flanged EPDM Non-Shock
* Inlet pressure over 75 PSI cannot be regulated

W W W. H AY WA R D F L O W C O N T R O L . C O M • 1 . 8 8 8 . 4 2 9 . 4 6 3 5 47
RV Series Pressure
Relief Valves
1/2" TO 2" PVC and CPVC

technical inFormation, continued


ParTs LisT OPEraTinG TEmPEraTurE / PrEssurE
160
1. Stem
2. Locknut 140

3. Spring Retainer

WORKING PRESSURE (PSI)


120

4. Spring (Plastic Coated) 100

5. Body
80
6. Gauge Port
7. O-Ring Seal 60

8. Piston 40

9. U-Cup Seal 20

0
60 80 100 120 140 160 180 200 220 240 260

TEMPERATURE ºF

dimEnsiOns
sizE a B C d E F WEiGHT
in / dn in / mm in / mm in / mm in / mm in / mm in / mm lb / kg

1/2 / 15 6.75 / 171 1.38 / 35 1.50 / 38 1.38 / 35 1.38 / 35 5.19 / 132 .50 / .23
3/4 / 20 6.88 / 175 1.50 / 38 1.75 / 44 1.56 / 40 1.63 / 41 5.44 / 138 .75 / .34
1 / 25 8.75 / 222 1.63 / 41 2.06 / 52 1.88 / 48 1.88 / 48 5.75 / 146 1.00 / .45
1-1/2 / 40 13.25 / 337 1.88 / 48 2.63 / 67 2.63 / 67 2.44 / 62 6.25 / 159 2.50 / 1.13
2 / 50 15.50 / 394 2.13 / 54 3.00 / 76 3.13 / 80 2.88 / 73 6.69 / 170 3.50 / 1.59
Dimensions are subject to change without notice – consult factory for installation information

rELiEF VaLVE FLOW CHarT


The chart below shows the flow rate out of the relief valve discharge port at a given set pressure and overpressure. For example, a 1" relief valve set to relieve
at 30 PSI would have a flow rate of 20 GPM out of the discharge port at 10 PSI of overpressure (system pressure at 40 PSI).

rELiEF VaLVE sizEs (nPT)


1/2" 3/4" 1" 1-1/2" 2"
OVErPrEssurE (Psi) OVErPrEssurE (Psi)
sET rELiEF OVErPrEssurE (Psi) OVErPrEssurE (Psi) OVErPrEssurE (Psi) +2* +5* +2* +5*
PrEssurE (Psi) +5 +10 +20 +5 +10 +20 +5 +10 +20
+5 +10 +20 +10 +20
FLOW raTE (GPm) FLOW raTE (GPm) FLOW raTE (GPm) FLOW raTE (GPm) FLOW raTE (GPm)

10 .5 2.0 6.0 3.0 4.0 9.0 7.0 11.0 18.0 1.0 15.0 20.0 22.5 110.0

20 1.0 3.0 7.0 4.0 6.0 15.0 8.0 14.0 24.0 1.5 30.0 33.0 40.0 125.0

30 1.0 3.0 8.0 5.5 9.0 17.5 8.0 20.0 27.0 5.0 40.0 45.0 55.0 147.0

40 1.0 3.0 8.0 9.0 13.0 19.0 8.0 27.5 30.0 8.0 47.5 51.0 75.0 160.0

50 N/A N/A N/A 9.0 15.0 21.0 8.0 33.0 36.0 10.0 69.0 72.0 83.0 180.0

75 N/A N/A N/A 9.0 18.0 20.0 8.0 40.0 48.0 10.0 90.0 96.0 92.0 180.0
* With Optional Low Pressure Spring

Hayward is a registered trademark


of Hayward Industries, Inc.
© 2011 Hayward Industries, Inc.

Contact Hayward Flow Control with questions: 1-888-429-4635 • Fax: 1-888-778-8410 • One Hayward Industrial Drive • Clemmons, NC 27012 • USA
Visit us at: www.haywardflowcontrol.com • E-mail: [email protected]
48