General Specifications: Model EJA210A and EJA220A Flange Mounted Differential Pressure Transmitters
General Specifications: Model EJA210A and EJA220A Flange Mounted Differential Pressure Transmitters
General Specifications: Model EJA210A and EJA220A Flange Mounted Differential Pressure Transmitters
STANDARD SPECIFICATIONS
Refer to GS 01C22T02-00E for FOUNDATION Fieldbus
communication type and GS 01C22T03-00E for
PROFIBUS PA communication type marked with “.”
PERFORMANCE SPECIFICATIONS
Zero-based calibrated span, linear output, wetted
parts material code‘S’ for 3-inch flange flush type and
4-inch flange extended type.
Reference Accuracy of Calibrated Span FUNCTIONAL SPECIFICATIONS
(including the effects of zero-based linearity, hyster-
esis, and repeatability) Span & Range Limits
Measurement
Span and Range kPa inH2O (/D1) mbar (/D3) mmH2O (/D4)
⫾0.075 % of Span Span 1 to 100 4 to 400 10 to 1000 100 to 10000
M
Range -100 to 100 -400 to 400 -1000 to 1000 -10000 to 10000
For spans below X,
Span 5 to 500 20 to 2000 50 to 5000 0.05 to 5 kgf/cm2
H
X Range -500 to 500 -2000 to 2000 -5000 to 5000 -5 to 5 kgf/cm2
⫾[0.025 + 0.05 ] % of Span
Span T01E.EPS
where X equals: URL is defined as the Upper Range Limit from the
Capsule X kPa {inH2O} table above.
M 10 {40} Zero Adjustment Limits
H 100 {400} Zero can be fully elevated or suppressed, within the
Lower and Upper Range Limits of the capsule.
Ambient Temperature Effects External Zero Adjustment “”
Total Effects per 28 ˚C (50 ˚F) Change External zero is continuously adjustable with 0.01 %
incremental resolution of span. Span may be
Capsule Effect adjusted locally using the digital indicator with range
M ⫾[0.224 % Span + 0.056 % URL] switch.
H ⫾[0.14 % Span + 0.028 % URL]
Output “”
Static Pressure Effects Two wire 4 to 20 mA DC output with digital communi-
cations. BRAIN or HART FSK protocol are superim-
Total Effects per Change posed on the 4 to 20 mA signal.
⫾[0.028 % Span+0.007 % URL] per 0.69 MPa
{100 psi} Failure Alarm
Output status at CPU failure and hardware error;
Effect on Zero (can be corrected at line pres- Up-scale: 110%, 21.6 mA DC or more(standard)
sure) Down-scale: -5%, 3.2 mA DC or less
⫾0.007 % of URL per 0.69 MPa {100 psi} -2.5%, 3.6 mA DC or less (Optional
Stability code /F1)
⫾0.1 % of URL per 60 months Note: Applicable for Output signal code D and E
Power Supply Effects “”
⫾0.005 % per Volt (from 21.6 to 32 V DC, 350 ⍀)
All Rights Reserved. Copyright © 1997, Yokogawa Electric Corporation GS 01C21C01-00E April 01, 2013-00
<<Contents>> <<Index>> 3
PHYSICAL SPECIFICATIONS < Settings When Shipped > “”
Wetted Parts Materials Tag Number As specified in order *1
High side: Output Mode ‘Linear’ unless otherwise specified in order
See wetted parts materials of the model code Display Mode ‘Linear’ unless otherwise specified in order
Low side: Operation Mode ‘Normal’ unless otherwise specified in order
Diaphragm Damping Time ‘2 sec.’
Hastelloy C-276 Constant *2
Cover flange Calibration Range
Lower Range Value As specified in order
SCS14A
Calibration Range As specified in order
Process connector Higher Range Value
SCS14A Selected from mmH2O, mmAq, mmWG,
Capsule Gasket Calibration Range mmHg, Pa, hPa, kPa, MPa, mbar, bar,
Units gf/cm2, kgf/cm2, inH2O, inHg, ftH2O, or psi.
Teflon-coated SUS316L (Only one unit can be specified)
Vent and Drain Plug T02E.EPS
SUS316 or ASTM grade 316 *1: Up to 16 alphanumeric characters for BRAIN and
8 characters for HART including ‘-’ and ‘.’ will be
Process Connector Gasket entered in the amplifier memory. If specified Tag
PTFE Teflon includes other characters than above, it will not
Non-wetted Parts Materials be entered in the amplifier memory.
*2: If using square root output, set damping time
Bolting constant to 2 sec. or more.
SCM435, SUS630, or SUH660
Housing < Related Instruments > “”
Low copper cast-aluminum alloy with polyurethane Power Distributor: Refer to GS 01B04T01-02E or
paint (Munsell 0.6GY3.1/2.0) GS 01B04T02-02E
Degrees of Protection BRAIN TERMINAL: Refer to GS 01C00A11-00E
IP67, NEMA4X
< Reference >
Cover O-rings 1. Teflon; Trademark of E.I. DuPont de Nemours & Co.
Buna-N, fluoro-rubber (optional) 2. Hastelloy; Trademark of Haynes International Inc.
Name plate and tag 3. HART; Trademark of the HART Communication
SUS304 or SUS316 (option) Foundation.
Fill Fluid 4. FOUNDATION; Trademark of Fieldbus Foundation.
Silicone, Fluorinated oil(option) 5. PROFIBUS; Registered trademark of Profibus
Nutzerorganisation e.v., Karlsruhe, Germany.
Weight Material Cross Reference Table
10.7 kg(23.6 lb) (Model EJA210A with 3” ANSI 150
flange; without integral indicator and SUS316L AISI 316L
process connector.) SUS316 AISI 316
16.1 kg(35.5 lb) (Model EJA220A with 4” ANSI 150 SUS304 AISI 304
flange, X2= 100; without integral indicator S25C AISI 1025
and process connector.)
SCM435 AISI 4137
Connections SUS630 ASTM630
Refer to the model code to specify the process and SCS14A ASTM CF-8M
electrical connection type. The high pressure side
T03E.EPS
will be a flange connected, low pressure side is 6. Other company names and product names used in
threaded. this material are registered trademarks or trademarks
Process Connection of Low Side Cover Flange: of their respective owners.
DIN 19213 with 7/16 inch ⫻ 20 unf female thread.
< Specification Conformance >
The model EJA210A/220A maintains a specification
conformance to at least 3 .
All Rights Reserved. Copyright © 1997, Yokogawa Electric Corporation GS 01C21C01-00E July 01, 2011-00
<<Contents>> <<Index>> 4
MODEL AND SUFFIX CODES
Model EJA210A [Process Flange size: 3-inch (80 mm)]
The ‘’ marks indicate the most typical selection for each specification. Example: EJA210A-DMSA1D5A-92NN/
The ‘#’marks indicate the construction materials conform to NACE material recommendations per MR01-75. For the use of
SUS316 material, there may be certain limitations for pressure and temperature. Please refer to NACE standards for details.
*1: Low pressure side wetted parts material: Cover flange; SCS14A, Process connector; SCS14A,
Capsule; SUSF316L, SUS316L or ASTM grade 316L (Diaphragm; Hastelloy C-276 or ASTM N10276), Vent plug; SUS316 or ASTM
grade 316
*2: Not applicable for Output signal code F and G.
*3: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropri-
ate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It
is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can
contaminate the user's process fluids.
Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite,
and high-temperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the wetted parts material.
*4: Hastelloy C-276 or ASTM N10276.
*5: SUS316 or ASTM grade 316.
*6: SUS304 or ASTM grade 304. Forged version may be used.
*7: SUS316 or ASTM grade 316. Forged version may be used.
All Rights Reserved. Copyright © 1997, Yokogawa Electric Corporation GS 01C21C01-00E Jul. 08, 2009-00
<<Contents>> <<Index>> 5
● Model EJA210A [Process Flange size: 2-inch (50 mm)]
The ‘’ marks indicate the most typical selection for each specification. Example: EJA210A-DMWA1A5A-92NN/
The ‘#’marks indicate the construction materials conform to NACE material recommendations per MR01-75. For the use of
SUS316 material, there may be certain limitations for pressure and temperature. Please refer to NACE standards for details.
*1: Low pressure side wetted parts material: Cover flange; SCS14A, Process connector; SCS14A,
Capsule; SUS316L (Diaphragm; Hastelloy C-276 or ASTM N10276), Vent plug; SUS316
*2: Not applicable for Output signal code F and G.
*3: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropri-
ate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It
is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can
contaminate the user's process fluids.
Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite,
and high-temperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the wetted parts material.
*4: Hastelloy C-276 or ASTM N10276.
*5: SUS316 or ASTM grade 316.
*6: SUS304 or ASTM grade 304. Forged version may be used.
*7: SUS316 or ASTM grade 316. Forged version may be used.
All Rights Reserved. Copyright © 1997, Yokogawa Electric Corporation GS 01C21C01-00E Jul, 08, 2009-00
<<Contents>> <<Index>> 6
● Model EJA220A
The ‘’ marks indicate the most typical selection for each specification. Example: EJA220A-DMSA12G5A-92NN/
The ‘#’marks indicate the construction materials conform to NACE material recommendations per MR01-75. For the use of
SUS316 material, there may be certain limitations for pressure and temperature. Please refer to NACE standards for details.
All Rights Reserved. Copyright © 1997, Yokogawa Electric Corporation GS 01C21C01-00E Jul. 08, 2009-00
<<Contents>> <<Index>> 7
*1: Low pressure side wetted parts material: Cover flange; SCS14A, Process connector; SCS14A,
Capsule; SUS316L (Diaphragm, Hastelloy C-276 or ASTM N10276), Vent plug; SUS316
*2: Applicable for 4-inch (100 mm) flange size (Process flange size/material G, H and J).
*3: Applicable for 3-inch (80 mm) flange size (Process flange size/material D, E and F).
*4: Not applicable for Output signal code F and G.
*5: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The
use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel
and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from
the broken diaphragm and the fill fluid can contaminate the user's process fluids.
Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide,
sodium hypochlorite, and high-temperature steam (150°C [302°F] or above). Contact Yokogawa for detailed
information of the wetted parts material.
*6: Hastelloy C-276 or ASTM N10276.
*7: Not applicable when option code /E1 is specified.
*8: SUS316 or ASTM grade 316.
*9: SUS304 or ASTM grade 304. Forged version may be used.
*10: SUS316 or ASTM grade 316. Forged version may be used.
*1: Applicable for Electrical connection code 2, 7 and C (1/2 NPT female).
*2: Applicable for Electrical connection code 2, 4, 7, 9, C and D (1/2 NPT and M20 female).
*3: Applicable for Output signal code D and E.
For intrinsically safe approval, use the safety barrier certified by the testing laboratories (BARD-400 is not applicable).
*4: Lower limit of ambient temperature is –15˚C (5˚F) when /HE is specified.
All Rights Reserved. Copyright © 1997, Yokogawa Electric Corporation GS 01C21C01-00E April 01, 2013-00
<<Contents>> <<Index>> 8
Item Description Code
CSA Explosionproof Approval *1 *3 *4
Applicable standard: C22.2 No. 0, No. 0.4, No. 25, No. 30, No. 94, No. 142
Certificate: 1089598
Explosionproof for Class I, Division 1, Groups B, C and D
Dustignitionproof for Class II/III, Division 1, Groups E, F and G
Division2 ‘SEALS NOT REQUIRED’ , Temp. Class: T4, T5, T6 Encl Type 4x
Max. Process Temp.: T4; 120⬚C (248⬚F), T5; 100⬚C (212⬚F), T6; 85⬚C (185⬚F) CF1
Amb. Temp.: –40 to 80⬚C (–40 to 176⬚F)
Process Sealing Certification
Dual Seal Certified by CSA to the requirement of ANSI/ISA 12.27.01
No additional sealing required. Primary seal failure annunciation:
at the zero adjustment screw
Canadian Standards
Association (CSA) CSA Intrinsically safe Approval *1 *3 *4
Applicable standard: C22.2 No. 0, No. 0.4, No. 25, No. 30, No. 94, No. 142, No. 157
No. 213
Certificate: 1053843
Class I, Groups A, B, C and D Class II and III, Groups E, F and G
Encl Type 4x, Temp. Class: T4, Amb. Temp.: –40 to 60⬚C (–40 to 140⬚F) CS1
Vmax=30 V, Imax=165 mA, Pmax=0.9 W, Ci=22.5 nF, Li=730 H
Process Sealing Certification
Dual Seal Certified by CSA to the requirement of ANSI/ISA 12.27.01
No additional sealing required. Primary seal failure annunciation:
at the zero adjustment screw
Combined CF1 and CS1 *1 *3 *4 CU1
IECEx Intrinsically safe, type n and Flameproof Approval *3 *4 *5
Intrinsically safe and type n
Applicable Standard: IEC 60079-0:2004, IEC 60079-11:1999, IEC 60079-15:2005,
IEC 60079-26:2005
Certificate: IECEx KEM 06.0007X
Ex ia IIC T4, Ex nL IIC T4 Enclosure: IP67
Amb. Temp.: –40 to 60⬚C (–40 to 140⬚F), Max. Process Temp.: 120⬚C (248⬚F)
IECEx Electrical Parameters: [Ex ia] Ui=30 V, Ii=165 mA, Pi=0.9 W, Ci=22.5 nF, Li=730 H
SU2
Scheme [Ex nL] Ui=30 V, Ci=22.5 nF, Li=730 H
Flameproof
Applicable Standard: IEC 60079-0:2004, IEC60079-1:2003
Certificate: IECEx KEM 06.0005
Ex d IIC T6...T4 Enclosure: IP67
Max.Process Temp.: T4;120⬚C (248⬚F), T5;100⬚C (212⬚F), T6; 85⬚C (185⬚F)
Amb.Temp.: –40 to 75⬚C (–40 to 167⬚F) for T4, –40 to 80⬚C (–40 to 176⬚F) for T5,
–40 to 75⬚C (–40 to 167⬚F) for T6
T07-2E.EPS
*1: Applicable for Electrical connection code 2, 7 and C (1/2 NPT female).
*2: Applicable for Electrical connection code 2, 4, 7, 9, C and D (1/2 NPT and M20 female).
*3: Applicable for Output signal code D and E.
For intrinsically safe approval, use the safety barrier certified by the testing laboratories (BARD-400 is not applicable).
*4: Lower limit of ambient temperature is –15˚C (5˚F) when /HE is specified.
*5: Applicable for Electrical connection code 2, 4, 7, C and D (1/2 NPT and M20 female).
OPTIONAL SPECIFICATIONS
Item Description Code
Amplifier cover only P
Color change
Painting *1 Amplifier cover and terminal cover, Munsell 7.5 R4/14 PR
Coating change Epoxy resin-baked coating *2 X1
Exterior parts on the amplifier housing(name plates, tag plate, zero-adjustment screw,
316 SST exterior parts HC
stopper screw) will become 316 SST *3
Fluoro-rubber O-ring All O-rings of amplifier housing. Lower limit of ambient temperature: ⫺15⬚C (5⬚F) HE
Transmitter power supply voltage: 10.5 to 32 V DC (10.5 to 30 V DC for intrinsically
Lightning protector safe type, 9 to 32 V DC for Fieldbus communication type.) A
Allowable current: Max. 6000 A (1⫻40 s), Repeating 1000 A (1⫻40 s) 100 times
T08E-1.EPS
*1: Standard polyurethan painting can be used in acid atmosphere, whereas the epoxy resin-baked coating (Option code
X1) can be used in alkaline atmosphere. Anti-corrosion coating, the combination of polyurethan and epoxy resin-baked
coating, is available by special order as sea water, alkaline, and acid resistant.
*2: Not applicable for color change option.
*3: 316 or 316L SST. The specification is included in option code /E1.
All Rights Reserved. Copyright © 1997, Yokogawa Electric Corporation GS 01C21C01-00E July 01, 2011-00
<<Contents>> <<Index>> 9
Gold-plate *6 Inside of isolating diaphragms (fill fluid side) are gold plated, effective for hydrogen permeation.
A1
(process flange side)
Wired tag plate Stainless steel tag plate wired onto transmitter N4
High pressure side: Process flange, Block *7
For M03
Low pressure side: Cover flange
model
High pressure side: Process flange, Block *8 EJA210A M13
Low pressure side: Cover flange, Process connector
Mill Certificate
High pressure side: Process flange, Block, Pipe, Base *7
For M04
Low pressure side: Cover flange
model
High pressure side: Process flange, Block, Pipe, Base *8 EJA220A
Low pressure side: Cover flange, Process connector M14
(Flange rating) (Test Pressure)
JIS 10K 2 MPa {20 kgf/cm2 } T31
Pressure test/Leak test JIS 20K 5 MPa {50 kgf/cm2 } T32
Certificate *14 ANSI/JPI Class 150 3 MPa {29.8 kgf/cm2 } Nitrogen (N2) Gas *11 T36
ANSI/JPI Class 300 7.7 MPa {77 kgf/cm2 } *9 Retention time: 10 minutes T37
ANSI/JPI Class 300 7 MPa {70 kgf/cm2 } *10 T38
T08E-2.EPS
*1: The unit of MWP (Max. working pressure) on name plate of a housing is the same unit as specified by Optional code D1,
D3, and D4.
*2: This item cannot be applied to model EJA210A Wetted parts material code H and T, whose gasket contact surface are
not serrated as standard specifications.
*3: Teflon film can only be specified for model EJA210A.
*4: Applicable for Output signal code D and E. The hardware error indicates faulty amplifier or capsule.
When combining with Option code F1, output status for down-scale is –2.5%, 3.6 mA DC or less.
*5: Applicable for Electrical connection code 2, 3, 4, A, C and D. Not applicable for Option code P and X1.
*6: Applicable for Wetted parts material code S and W .
Consult Yokogawa in case gold-plated disphragm is required for low pressure side.
*7: Applicable for Low Pressure Side Process connection code 0 and 5.
*8: Applicable for Low Pressure Side Process connection code 1, 2, 3, and 4.
*9: Applicable for model EJA210A.
*10: Applicable for model EJA220A.
*11: Pure nitrogen gas is used for oil-prohibited use (Option code K1, K2, K5, and K6 ).
*12: Applicable for Output signal code D and E. Write protection switch is attached for Output code E.
*13: Not applicable for Option code C1.
*14: The unit on the certificate is always MPa regardless of selection of option code D1, D3, or D4.
*15: Applicable for Output signal code E.
All Rights Reserved. Copyright © 1997, Yokogawa Electric Corporation GS 01C21C01-00E Oct. 01, 2008-00
<<Contents>> <<Index>> 10
DIMENSIONS
Model EJA210A
Unit: mm (approx.inch)
174 (6.85) 30 (1.18)
110 (4.33)
External indicator
conduit connection 133 (5.24) 72 Conduit Zero 35
connection adjustment
(Optional) (2.83) (1.38)
46 Drain plug
Process
(1.81) connector n- øh
(Optional) 54 37 *2
Process flange (2.13) (1.46)
All Rights Reserved. Copyright © 1997, Yokogawa Electric Corporation GS 01C21C01-00E Mar. 23, 2006-00
<<Contents>> <<Index>> 11
Model EJA220A
Unit: mm (approx.inch)
174 (6.85) 30 (1.18)
110 (4.33)
External indicator
conduit connection 133 (5.24) 72 Conduit Zero 35
connection adjustment
(Optional) (2.83) (1.38)
All Rights Reserved. Copyright © 1997, Yokogawa Electric Corporation GS 01C21C01-00E Mar. 23, 2006-00
<<Contents>> <<Index>> 12
● Terminal Configuration ● Terminal Wiring
SUPPLY +
– Power supply and output terminal
+
CHECK – External indicator(ammeter) terminal*1
SELECTION GUIDE
Measurement Span Maximum Working Pressure
Application Type Model Capsule
kPa inH2O MPa psi
L 0.5 to 10 2 to 40 16*4 2250*4
Differential M 1 to 100 4 to 400 16 2250
Pressure Traditional-Mounting*1 EJA110A
H 5 to 500 20 to 2000 16 2250
V 0.14 to 14MPa 20 to 2000 psi 16 2250
L 1 to 10 4 to 40 3.5 500
Flow Integral Orifice EJA115 M 2 to 100 8 to 400 14 2000
H 20 to 210 80 to 830 14 2000
Differential Pressure Extended EJA118N M 2.5 to 100 10 to 400
& Liquid Level Flush EJA118W 25 to 500 Based on Flange Rating
H 100 to 2000
with Remote Seals Combination EJA118Y
Draft Range Traditional-Mounting*1 EJA120A E 0.1 to 1 0.4 to 4 50 kPa 7.25
Differential Pressure Traditional-Mounting*1 M 1 to 100 4 to 400 32 4500
& Liquid Level EJA130A
H 5 to 500 20 to 2000 32 4500
Liquid Level, Closed Flush EJA210A M 1 to 100 4 to 400
20 to 2000 Based on Flange Rating
or Open Tank Extended EJA220A H 5 to 500
L 0.67 to 10*2 2.67 to 40*2 10 kPa*2 40 in H2O*2
Absolute (vacuum) 130 kPa*2
Pressure Traditional-Mounting*1 EJA310A M 1.3 to 130*2 0.38 to 38 inHg*2 18.65*2
A 0.03 to 3 MPa*2 4.3 to 430 psi*2 3000 kPa*2 430*2
A 0.03 to 3 MPa 4.3 to 430 psi 3 430
Gauge Pressure Traditional-Mounting*1 EJA430A 0.14 to 14 MPa 20 to 2000 psi 14 2000
B
Gauge Pressure Extended EJA438N A 0.06 to 3 MPa 8.6 to 430 psi Based on Flange Rating
with Remote Seal B 0.46 to 7 MPa 66 to 1000 psi
Gauge Pressure A 0.06 to 3 MPa 8.6 to 430 psi
Flush EJA438W 66 to 2000 psi Based on Flange Rating
with Remote Seal B 0.46 to 14 MPa
C 5 to 32 MPa 720 to 4500 psi 32 4500
High Gauge Traditional-Mounting*1 EJA440A 5 to 50 MPa 720 to 7200 psi
D 50 7200
A 10 to 200 1.45 to 29 psi 200 kPa 29
Absolute & Gauge EJA510A B 0.1 to 2 MPa 14.5 to 290 psi 2 290
Direct-Mounting
Pressure*3 EJA530A C 0.5 to 10 MPa 72.5 to 1450 psi 10 1450
D 5 to 50 MPa 720 to 7200 psi 50 7200
T09E.EPS
*1: Traditional-mounting is 1/4 - 18 NPTF process connections ( 1/2 - 14 NPTF with process adapters ) on 2-1/8" centers.
*2: Measurement values in absolute.
*3: Measurement values in absolute for EJA510A.
*4: When combined with Wetted parts material code H, M, T, A, D, and B, the value is 3.5 MPa (500 psi).
< Ordering Information > “” 4. Display scale and units (for transmitters equipped
Specify the following when ordering with integral indicator only)
1. Model, suffix codes, and optional codes Specify either 0 to 100 % or engineering unit scale
2. Calibration range and units: and ‘Range and Unit’ for engineering units scale:
1) Calibration range can be specified with range value Scale range can be specified with range limit
specifications up to 5 digits specifications up to 5 digits (excluding any decimal
(excluding any decimal point) for low or high range point) for low or high range limits within the range of
limits within the range of -32000 to 32000. -19999 to 19999.
2) Specify only one unit from the table, ‘Settings when 5. Tag Number (if required)
shipped.’
3. Select linear or square root for output mode and
display mode.
Note: If not specified, the instrument is shipped in
normal operation mode.
All Rights Reserved. Copyright © 1997, Yokogawa Electric Corporation GS 01C21C01-00E June 01, 2007-00
Subject to change without notice.