General Specifications: Model EJA210A and EJA220A Flange Mounted Differential Pressure Transmitters

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

<<Contents>> <<Index>>

General Model EJA210A and EJA220A


Specifications Flange Mounted Differential Pressure
Transmitters
GS 01C21C01-00E

The high performance flange mounted differential


pressure transmitter models EJA210A and 220A can
be used to measure levels of densities of solidifying or
precipitating liquids. Both output a 4 to 20 mA DC
signal corresponding to the measured differential
pressure. Models EJA210A and 220A also feature
remote setup and monitoring through communications
with the BRAIN™ terminal and CENTUM CS™ or
␮XL™ or HART® 275 host.

 STANDARD SPECIFICATIONS
Refer to GS 01C22T02-00E for FOUNDATION Fieldbus
communication type and GS 01C22T03-00E for
PROFIBUS PA communication type marked with “.”

 PERFORMANCE SPECIFICATIONS
Zero-based calibrated span, linear output, wetted
parts material code‘S’ for 3-inch flange flush type and
4-inch flange extended type.
Reference Accuracy of Calibrated Span  FUNCTIONAL SPECIFICATIONS
(including the effects of zero-based linearity, hyster-
esis, and repeatability) Span & Range Limits
Measurement
Span and Range kPa inH2O (/D1) mbar (/D3) mmH2O (/D4)
⫾0.075 % of Span Span 1 to 100 4 to 400 10 to 1000 100 to 10000
M
Range -100 to 100 -400 to 400 -1000 to 1000 -10000 to 10000
For spans below X,
Span 5 to 500 20 to 2000 50 to 5000 0.05 to 5 kgf/cm2
H
X Range -500 to 500 -2000 to 2000 -5000 to 5000 -5 to 5 kgf/cm2
⫾[0.025 + 0.05 ] % of Span
Span T01E.EPS

where X equals: URL is defined as the Upper Range Limit from the
Capsule X kPa {inH2O} table above.
M 10 {40} Zero Adjustment Limits
H 100 {400} Zero can be fully elevated or suppressed, within the
Lower and Upper Range Limits of the capsule.
Ambient Temperature Effects External Zero Adjustment “”
Total Effects per 28 ˚C (50 ˚F) Change External zero is continuously adjustable with 0.01 %
incremental resolution of span. Span may be
Capsule Effect adjusted locally using the digital indicator with range
M ⫾[0.224 % Span + 0.056 % URL] switch.
H ⫾[0.14 % Span + 0.028 % URL]
Output “”
Static Pressure Effects Two wire 4 to 20 mA DC output with digital communi-
cations. BRAIN or HART FSK protocol are superim-
Total Effects per Change posed on the 4 to 20 mA signal.
⫾[0.028 % Span+0.007 % URL] per 0.69 MPa
{100 psi} Failure Alarm
Output status at CPU failure and hardware error;
Effect on Zero (can be corrected at line pres- Up-scale: 110%, 21.6 mA DC or more(standard)
sure) Down-scale: -5%, 3.2 mA DC or less
⫾0.007 % of URL per 0.69 MPa {100 psi} -2.5%, 3.6 mA DC or less (Optional
Stability code /F1)
⫾0.1 % of URL per 60 months Note: Applicable for Output signal code D and E
Power Supply Effects “”
⫾0.005 % per Volt (from 21.6 to 32 V DC, 350 ⍀)

Yokogawa Electric Corporation GS 01C21C01-00E


2-9-32 Nakacho, Musashino-shi, Tokyo, 180-8750 Japan ©Copyright June 1997
Phone: 81-422-52-5690 Fax: 81-422-52-2018 25th Edition April 2013
<<Contents>> <<Index>> 2
Damping Time Constant (1st order) Supply Voltage “”
The sum of the amplifier and capsule damping time 10.5 to 42 V DC for general use and flameproof type
constant must be used for the overall time constant. 10.5 to 32 V DC for lightning protector (Optional
Amp damping time constant is adjustable from 0.2 to code /A)
64 seconds. 10.5 to 30 V DC for intrinsically safe, Type n,
nonincendive, or non-sparking type
Model EJA210A EJA220A Minimum voltage limited at 16.4 V DC for digital
Capsule (Silicone Oil) M H M H communications, BRAIN and HART
Time Constant (sec.) 0.4 0.4 0.4 0.4

Ambient Temperature Limits


(approval codes may affect limits) 600
-40 to 85 ˚C (-40 to 185 ˚F)
E-10.5
-30 to 80 ˚C (-22 to 176 ˚F) with LCD Display R=
0.0236 Digital
Process Temperature Limits External Communication
(approval codes may affect limits) load range
-40 to 120 ˚C (-40 to 248 ˚F) resistance BRAIN and HART

Ambient Humidity Limits 250


5 to 100 % RH @ 40 ˚C (104 ˚F)
R (⍀)
Working Pressure Limits (Silicone Oil)
2.7 kPa abs(0.38 psia) to flange rating (see graph
below)
10.5 16.4 24.7 42
Power supply voltage E (V DC)
F02E.EPS
100{14.5} Atmospheric
Figure 2. Relationship Between Power Supply Voltage
pressure
Working and External Load Resistance
pressure
kPa abs
{psi abs}
Load (Output signal code D and E)
Applicable range 0 to 1335 ⍀ for operation
10{1.4} 250 to 600 ⍀ for digital communication
Communication Requirements “”
BRAIN
2.7{0.38} Communication Distance
Up to 2 km (1.25 miles) when using CEV polyethyl-
1{0.14} ene-insulated PVC-sheathed cables. Communication
-40 0 40 80 120 distance varies depending on type of cable used.
(-40) (32) (104) (176) (248) Load Capacitance
Process temperature ⬚C (⬚F) 0.22 ␮F or less (see note)
F01E.EPS
Load Inductance
Figure 1. Working Pressure and Process Temperature
3.3 mH or less (see note)
Spacing from power line
EMC Conformity Standards “” , 15 cm or more.
EN61326-1 Class A, Table2 (For use in industrial Input Impedance of communicating device
locations) 10 k⍀ or more at 2.4 kHz.
EN61326-2-3
Note : For general-use and Flameproof type.
European Pressure Equipment Directive 97/23/EC For Intrinsically safe type, please refer to
‘OPTIONAL SPECIFICATIONS.’
Sound Engineering Practice

Safety Requirement Standards


EN61010-1
• Altitude of installation site: Max. 2,000 m above sea level
• Installation category: I
• Pollution degree: 2
• Indoor/Outdoor use

Supply & Load Requirements


(Safety approvals may affect electrical requirements)
With 24 V DC supply, up to a 570 ⍀ load can be
used. See Figure 2.

All Rights Reserved. Copyright © 1997, Yokogawa Electric Corporation GS 01C21C01-00E April 01, 2013-00
<<Contents>> <<Index>> 3
 PHYSICAL SPECIFICATIONS < Settings When Shipped > “”
Wetted Parts Materials Tag Number As specified in order *1
High side: Output Mode ‘Linear’ unless otherwise specified in order
See wetted parts materials of the model code Display Mode ‘Linear’ unless otherwise specified in order
Low side: Operation Mode ‘Normal’ unless otherwise specified in order
Diaphragm Damping Time ‘2 sec.’
Hastelloy C-276 Constant *2
Cover flange Calibration Range
Lower Range Value As specified in order
SCS14A
Calibration Range As specified in order
Process connector Higher Range Value
SCS14A Selected from mmH2O, mmAq, mmWG,
Capsule Gasket Calibration Range mmHg, Pa, hPa, kPa, MPa, mbar, bar,
Units gf/cm2, kgf/cm2, inH2O, inHg, ftH2O, or psi.
Teflon-coated SUS316L (Only one unit can be specified)
Vent and Drain Plug T02E.EPS

SUS316 or ASTM grade 316 *1: Up to 16 alphanumeric characters for BRAIN and
8 characters for HART including ‘-’ and ‘.’ will be
Process Connector Gasket entered in the amplifier memory. If specified Tag
PTFE Teflon includes other characters than above, it will not
Non-wetted Parts Materials be entered in the amplifier memory.
*2: If using square root output, set damping time
Bolting constant to 2 sec. or more.
SCM435, SUS630, or SUH660
Housing < Related Instruments > “”
Low copper cast-aluminum alloy with polyurethane Power Distributor: Refer to GS 01B04T01-02E or
paint (Munsell 0.6GY3.1/2.0) GS 01B04T02-02E
Degrees of Protection BRAIN TERMINAL: Refer to GS 01C00A11-00E
IP67, NEMA4X
< Reference >
Cover O-rings 1. Teflon; Trademark of E.I. DuPont de Nemours & Co.
Buna-N, fluoro-rubber (optional) 2. Hastelloy; Trademark of Haynes International Inc.
Name plate and tag 3. HART; Trademark of the HART Communication
SUS304 or SUS316 (option) Foundation.
Fill Fluid 4. FOUNDATION; Trademark of Fieldbus Foundation.
Silicone, Fluorinated oil(option) 5. PROFIBUS; Registered trademark of Profibus
Nutzerorganisation e.v., Karlsruhe, Germany.
Weight Material Cross Reference Table
10.7 kg(23.6 lb) (Model EJA210A with 3” ANSI 150
flange; without integral indicator and SUS316L AISI 316L
process connector.) SUS316 AISI 316
16.1 kg(35.5 lb) (Model EJA220A with 4” ANSI 150 SUS304 AISI 304
flange, X2= 100; without integral indicator S25C AISI 1025
and process connector.)
SCM435 AISI 4137
Connections SUS630 ASTM630
Refer to the model code to specify the process and SCS14A ASTM CF-8M
electrical connection type. The high pressure side
T03E.EPS
will be a flange connected, low pressure side is 6. Other company names and product names used in
threaded. this material are registered trademarks or trademarks
Process Connection of Low Side Cover Flange: of their respective owners.
DIN 19213 with 7/16 inch ⫻ 20 unf female thread.
< Specification Conformance >
The model EJA210A/220A maintains a specification
conformance to at least 3 ␴.

All Rights Reserved. Copyright © 1997, Yokogawa Electric Corporation GS 01C21C01-00E July 01, 2011-00
<<Contents>> <<Index>> 4
 MODEL AND SUFFIX CODES
Model EJA210A [Process Flange size: 3-inch (80 mm)]

Model Suffix Codes Description


EJA210A . . . . . . . . . . . . . . . . . . . . . Flange-mounted differential pressure transmitter
(Flush diaphragm type)
Output Signal -D . . . . . . . . . . . . . . . . . . 4 to 20 mA DC with digital communication (BRAIN protocol)
-E . . . . . . . . . . . . . . . . . . 4 to 20 mA DC with digital communication (HART protocol, refer to GS 01C22T01-00E)
-F . . . . . . . . . . . . . . . . . . Digital communication (FOUNDATION Fieldbus protocol, refer to GS 01C22T02-00E)
-G . . . . . . . . . . . . . . . . . . Digital communication (PROFIBUS PA protocol, refer to GS 01C22T03-00E)
Measurement span M . . . . . . . . . . . . . . . . . 1 to 100 kPa {100 to 10000 mmH2O} {4 to 400 inH2O} {10 to 1000 mbar}
(capsule) H . . . . . . . . . . . . . . . . . . 5 to 500 kPa {0.05 to 5 kgf/cm2} {20 to 2000 inH2O} {50 to 5000 mbar}
High pressure side [Diaphragm] [Others]
(Process flange side) S# . . . . . . . . . . . . . . . . SUS316L SUS316*5
wetted parts H# . . . . . . . . . . . . . . . . Hastelloy C-276*4 Hastelloy C-276*4
material*1*3 T . . . . . . . . . . . . . . . . Tantalum Tantalum
Process flange rating J1 . . . . . . . . . . . . . . JIS10K
J2 . . . . . . . . . . . . . . JIS20K
A1 . . . . . . . . . . . . . . ANSI Class 150 P1 . . . . . . . . . . JPI Class150
A2 . . . . . . . . . . . . . . ANSI Class 300 P2 . . . . . . . . . . JPI Class 300
D2 . . . . . . . . . . . . . . DIN PN10/16
D4 . . . . . . . . . . . . . . DIN PN25/40
Process flange  D . . . . . . . . . . . . . . 3-inch (80 mm) / S25C
size / material E . . . . . . . . . . . . . . 3-inch (80 mm) / SUS304*6
F . . . . . . . . . . . . . . 3-inch (80 mm) / SUS316*7
Low pressure side process 0 . . . . . . . . . . . . . without process connector (Rc1/4 female on the cover flange)
connection 1 . . . . . . . . . . . . . with Rc1/4 female process connector
2 . . . . . . . . . . . . . with Rc1/2 female process connector
3 . . . . . . . . . . . . . with 1/4NPT female process connector
4 . . . . . . . . . . . . . with 1/2NPT female process connector
 5 . . . . . . . . . . . . . without process connector (1/4 NPT female on the cover flange)
Bolts and nuts material  A . . . . . . . . . . . SCM435
B . . . . . . . . . . . SUS630
C . . . . . . . . . . . SUH660
Installation -9 . . . . . . . . . . Horizontal impulse piping type, left side high pressure
Electrical connection 0 . . . . . . . . . G1/2 female, one electrical connection
 2 . . . . . . . . . 1/2 NPT female, two electrical connections without blind plug
3 . . . . . . . . . Pg 13.5 female, two electrical connections without blind plug
4 . . . . . . . . . M20 female, two electrical connections without blind plug
5 . . . . . . . . . G1/2 female, two electrical connections and a blind plug
7 . . . . . . . . . 1/2 NPT female, two electrical connections and a blind plug
8 . . . . . . . . . Pg 13.5 female, two electrical connections and a blind plug
9 . . . . . . . . . M20 female, two electrical connections and a blind plug
A . . . . . . . . . G1/2 female, two electrical connections and a SUS316 blind plug
C . . . . . . . . . 1/2 NPT female, two electrical connections and a SUS316 blind plug
D . . . . . . . . . M20 female, two electrical connections and a SUS316 blind plug
Integral indicator D . . . . . . . . Digital indicator
E . . . . . . . . Digital indicator with the range setting switch*2
 N . . . . . . . . (None)
N . . . . . . Always N
Optional codes / Optional specification
T04E.EPS

The ‘’ marks indicate the most typical selection for each specification. Example: EJA210A-DMSA1D5A-92NN/
The ‘#’marks indicate the construction materials conform to NACE material recommendations per MR01-75. For the use of
SUS316 material, there may be certain limitations for pressure and temperature. Please refer to NACE standards for details.
*1: Low pressure side wetted parts material: Cover flange; SCS14A, Process connector; SCS14A,
Capsule; SUSF316L, SUS316L or ASTM grade 316L (Diaphragm; Hastelloy C-276 or ASTM N10276), Vent plug; SUS316 or ASTM
grade 316
*2: Not applicable for Output signal code F and G.
*3: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropri-
ate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It
is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can
contaminate the user's process fluids.
Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite,
and high-temperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the wetted parts material.
*4: Hastelloy C-276 or ASTM N10276.
*5: SUS316 or ASTM grade 316.
*6: SUS304 or ASTM grade 304. Forged version may be used.
*7: SUS316 or ASTM grade 316. Forged version may be used.

All Rights Reserved. Copyright © 1997, Yokogawa Electric Corporation GS 01C21C01-00E Jul. 08, 2009-00
<<Contents>> <<Index>> 5
● Model EJA210A [Process Flange size: 2-inch (50 mm)]

Model Suffix Codes Description


EJA210A . . . . . . . . . . . . . . . . . . . . . Flange-mounted differential pressure transmitter
(Flush diaphragm type)
Output Signal -D . . . . . . . . . . . . . . . . . . 4 to 20 mA DC with digital communication (BRAIN protocol)
-E . . . . . . . . . . . . . . . . . . 4 to 20 mA DC with digital communication (HART protocol, refer to GS 01C22T01-00E)
-F . . . . . . . . . . . . . . . . . . Digital communication (FOUNDATION Fieldbus protocol, refer to GS 01C22T02-00E)
-G . . . . . . . . . . . . . . . . . . Digital communication (PROFIBUS PA protocol, refer to GS 01C22T03-00E)
Measurement span M . . . . . . . . . . . . . . . . . 1 to 100 kPa {100 to 10000 mmH2O} {4 to 400 inH2O} {10 to 1000 mbar}
(capsule) H . . . . . . . . . . . . . . . . . . 5 to 500 kPa {0.05 to 5 kgf/cm2} {20 to 2000 inH2O} {50 to 5000 mbar}
[Diaphragm] [Others]
High pressure side
(Process flange side) W# . . . . . . . . . . . . . . . Hastelloy C-276*4 SUS316*5
wetted parts
material*1*3
Process flange rating J1 . . . . . . . . . . . . . . JIS10K
J2 . . . . . . . . . . . . . . JIS20K
A1 . . . . . . . . . . . . . . ANSI Class 150 P1 . . . . . . . . . . JPI Class150
A2 . . . . . . . . . . . . . . ANSI Class 300 P2 . . . . . . . . . . JPI Class 300
D2 . . . . . . . . . . . . . . DIN PN10/16
D4 . . . . . . . . . . . . . . DIN PN25/40
Process flange  A . . . . . . . . . . . . . . 2-inch (50 mm) / S25C
size / material B . . . . . . . . . . . . . . 2-inch (50 mm) / SUS304*6
C . . . . . . . . . . . . . . 2-inch (50 mm) / SUS316*7
Low pressure side process 0............. without process connector (Rc1/4 female on the cover flange)
connection 1............. with Rc1/4 female process connector
2............. with Rc1/2 female process connector
3............. with 1/4NPT female process connector
4............. with 1/2NPT female process connector
 5............. without process connector (1/4 NPT female on the cover flange)
Bolts and nuts material  A........... SCM435
B........... SUS630
C........... SUH660
Installation -9 . . . . . . . . . . Horizontal impulse piping type, left side high pressure
Electrical connection 0......... G1/2 female, one electrical connection
 2......... 1/2 NPT female, two electrical connections without blind plug
3......... Pg 13.5 female, two electrical connections without blind plug
4......... M20 female, two electrical connections without blind plug
5......... G1/2 female, two electrical connections and a blind plug
7......... 1/2 NPT female, two electrical connections and a blind plug
8......... Pg 13.5 female, two electrical connections and a blind plug
9......... M20 female, two electrical connections and a blind plug
A......... G1/2 female, two electrical connections and a SUS316 blind plug
C......... 1/2 NPT female, two electrical connections and a SUS316 blind plug
D......... M20 female, two electrical connections and a SUS316 blind plug
Integral indicator D........ Digital indicator
E........ Digital indicator with the range setting switch*2
 N........ (None)
N...... Always N
Optional codes / Optional specification
T05E.EPS

The ‘’ marks indicate the most typical selection for each specification. Example: EJA210A-DMWA1A5A-92NN/
The ‘#’marks indicate the construction materials conform to NACE material recommendations per MR01-75. For the use of
SUS316 material, there may be certain limitations for pressure and temperature. Please refer to NACE standards for details.
*1: Low pressure side wetted parts material: Cover flange; SCS14A, Process connector; SCS14A,
Capsule; SUS316L (Diaphragm; Hastelloy C-276 or ASTM N10276), Vent plug; SUS316
*2: Not applicable for Output signal code F and G.
*3: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropri-
ate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It
is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can
contaminate the user's process fluids.
Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite,
and high-temperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the wetted parts material.
*4: Hastelloy C-276 or ASTM N10276.
*5: SUS316 or ASTM grade 316.
*6: SUS304 or ASTM grade 304. Forged version may be used.
*7: SUS316 or ASTM grade 316. Forged version may be used.

All Rights Reserved. Copyright © 1997, Yokogawa Electric Corporation GS 01C21C01-00E Jul, 08, 2009-00
<<Contents>> <<Index>> 6
● Model EJA220A

Model Suffix Codes Description


EJA220A ................... Flange-mounted differential pressure transmitter
(Extended diaphragm type)
Output Signal -D . . . . . . . . . . . . . . . . . 4 to 20 mA DC with digital communication (BRAIN protocol)
-E . . . . . . . . . . . . . . . . . 4 to 20 mA DC with digital communication (HART protocol, refer to GS 01C22T01-00E)
-F . . . . . . . . . . . . . . . . . Digital communication (FOUNDATION Fieldbus protocol, refer to GS 01C22T02-00E)
-G . . . . . . . . . . . . . . . . . Digital communication (PROFIBUS PA protocol, refer to GS 01C22T03-00E)
Measurement span M................ 1 to 100 kPa {100 to 10000 mmH2O} {4 to 400 inH2O} {10 to 1000 mbar}
(capsule) H................ 5 to 500 kPa {0.05 to 5 kgf/cm2} {20 to 2000 inH2O} {50 to 5000 mbar}
High pressure side [Diaphragm] [Pipe] [Others]
(Process flange side) S*2 #. . . . . . . . . . . . . SUS316L SUS316 SUS316*8
*1*5
wetted parts material W*3 #. . . . . . . . . . . . . Hastelloy C-276*6 SUS316 SUS316*8
Process flange rating J1 . . . . . . . . . . . . JIS10K
J2 . . . . . . . . . . . . . JIS20K
A1 . . . . . . . . . . . . . ANSI Class 150 P1 . . . . . . . . . . JPI Class150
A2 . . . . . . . . . . . . . ANSI Class 300 P2 . . . . . . . . . . JPI Class 300
D2 . . . . . . . . . . . . . DIN PN10/16
D4 . . . . . . . . . . . . . DIN PN25/40
Diaphragm extension  2............. X2=50 mm
length (X2) 4............. X2=100 mm
6............. X2=150 mm
Process flange  G........... 4-inch (100 mm) / S25C
size/material H........... 4-inch (100 mm) / SUS304*9
J........... 4-inch (100 mm) / SUS316*10
D........... 3-inch (80 mm) / S25C
E........... 3-inch (80 mm) / SUS304*9
F........... 3-inch (80 mm) / SUS316*10
Low pressure side process 0 .......... without process connector (Rc1/4 female on the cover flanges)
connection 1 .......... with Rc1/4 female process connector
2 .......... with Rc1/2 female process connector
3 .......... with 1/4 NPT female process connector
4 .......... with 1/2 NPT female process connector
 5 .......... without process connector (1/4 NPT female on the cover flanges)
Bolts and nuts material  A......... SCM435
B......... SUS630
C......... SUH660
Installation -9 . . . . . . . Horizontal impulse piping type, left side high pressure
Electrical connection 0 . . . . . . G1/2 female, one electrical connection
 2 . . . . . . 1/2 NPT female, two electrical connections without blind plug
3 . . . . . . Pg 13.5 female, two electrical connections without blind plug
4 . . . . . . M20 female, two electrical connections without blind plug
5 . . . . . . G1/2 female, two electrical connections and a blind plug *7
7 . . . . . . 1/2 NPT female, two electrical connections and a blind plug *7
8 . . . . . . Pg 13.5 female, two electrical connections and a blind plug *7
9 . . . . . . M20 female, two electrical connections and a blind plug *7
A . . . . . . G1/2 female, two electrical connections and a SUS316 blind plug
C . . . . . . 1/2 NPT female, two electrical connections and a SUS316 blind plug
D . . . . . . M20 female, two electrical connections and a SUS316 blind plug
Integral indicator D . . . . . Digital indicator
E . . . . . Digital indicator with the range setting switch*4
 N . . . . . (None)
N . . . . Always N
Optional codes / Optional specification
T06E.EPS

The ‘’ marks indicate the most typical selection for each specification. Example: EJA220A-DMSA12G5A-92NN/
The ‘#’marks indicate the construction materials conform to NACE material recommendations per MR01-75. For the use of
SUS316 material, there may be certain limitations for pressure and temperature. Please refer to NACE standards for details.

All Rights Reserved. Copyright © 1997, Yokogawa Electric Corporation GS 01C21C01-00E Jul. 08, 2009-00
<<Contents>> <<Index>> 7
*1: Low pressure side wetted parts material: Cover flange; SCS14A, Process connector; SCS14A,
Capsule; SUS316L (Diaphragm, Hastelloy C-276 or ASTM N10276), Vent plug; SUS316
*2: Applicable for 4-inch (100 mm) flange size (Process flange size/material G, H and J).
*3: Applicable for 3-inch (80 mm) flange size (Process flange size/material D, E and F).
*4: Not applicable for Output signal code F and G.
*5: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The
use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel
and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from
the broken diaphragm and the fill fluid can contaminate the user's process fluids.
Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide,
sodium hypochlorite, and high-temperature steam (150°C [302°F] or above). Contact Yokogawa for detailed
information of the wetted parts material.
*6: Hastelloy C-276 or ASTM N10276.
*7: Not applicable when option code /E1 is specified.
*8: SUS316 or ASTM grade 316.
*9: SUS304 or ASTM grade 304. Forged version may be used.
*10: SUS316 or ASTM grade 316. Forged version may be used.

 OPTIONAL SPECIFICATIONS (For Explosion Protected type “”)


For FOUNDATION Fieldbus explosion protected type, see GS 01C22T02-00E.
For PROFIBUS PA explosion protected type, see GS 01C22T03-00E.

Item Description Code


FM Explosionproof Approval *1 *3 *4
Applicable standard: FM3600, FM3615, FM3810, ANSI/NEMA250
Explosionproof for Class I, Division 1, Groups B, C and D FF1
Dust-ignitionproof for Class II/III, Division 1, Groups E, F and G
Hazardous (classified) locations, indoors and outdoors (NEMA 4X)
Temperature class: T6 Amb. Temp.: –40 to 60⬚C (–40 to 140⬚F)
FM Intrinsically safe Approval *1 *3 *4
Applicable standard: FM3600, FM3610, FM3611, FM3810, ANSI/NEMA250
Factory Mutual (FM) Intrinsically Safe for Class I, Division 1, Groups A, B, C & D, Class II, Division 1,
Groups E, F & G and Class III, Division 1 Hazardous Locations.
Nonincendive for Class I, Division 2, Groups A, B, C & D, Class II, Division. 2,
Groups E, F & G, and Class III, Division 1 Hazardous Locations.
FS1
Enclosure: “NEMA 4X”, Temp. Class: T4, Amb. Temp.: –40 to 60⬚C (–40 to 140⬚F)
Intrinsically Safe Apparatus Parameters
[Groups A, B, C, D, E, F and G]
Vmax=30 V, Imax=165 mA, Pmax=0.9 W, Ci=22.5 nF, Li=730 ␮H
[Groups C, D, E, F and G]
Vmax=30 V, Imax=225 mA, Pmax=0.9 W, Ci=22.5 nF, Li=730 ␮H
Combined FF1 and FS1 *1 *3 *4 FU1
ATEX Flameproof Approval *2 *4
Applicable standard: EN 60079-0, EN 60079-1
Certificate: KEMA 02ATEX2148 II 2G Ex d IIC T4, T5, T6 KF21
Amb. Temp.: T5; –40 to 80⬚C ( –40 to 176⬚F), T4 and T6; –40 to 75⬚C ( –40 to 167⬚F)
Max. process Temp.: T4; 120⬚C (248⬚F), T5; 100⬚C (212⬚F), T6; 85⬚C (185⬚F)
ATEX
ATEX Intrinsically safe Approval *2 *3 *4
Applicable standard: EN50014, EN50020, EN50284
Certificate: KEMA 02ATEX1030X II 1G EEx ia IIC T4, Amb. Temp.: –40 to 60⬚C KS2
Ui=30 V, Ii=165 mA, Pi=0.9 W, Ci=22.5 nF, Li=730 ␮H
T07-1E.EPS

*1: Applicable for Electrical connection code 2, 7 and C (1/2 NPT female).
*2: Applicable for Electrical connection code 2, 4, 7, 9, C and D (1/2 NPT and M20 female).
*3: Applicable for Output signal code D and E.
For intrinsically safe approval, use the safety barrier certified by the testing laboratories (BARD-400 is not applicable).
*4: Lower limit of ambient temperature is –15˚C (5˚F) when /HE is specified.

All Rights Reserved. Copyright © 1997, Yokogawa Electric Corporation GS 01C21C01-00E April 01, 2013-00
<<Contents>> <<Index>> 8
Item Description Code
CSA Explosionproof Approval *1 *3 *4
Applicable standard: C22.2 No. 0, No. 0.4, No. 25, No. 30, No. 94, No. 142
Certificate: 1089598
Explosionproof for Class I, Division 1, Groups B, C and D
Dustignitionproof for Class II/III, Division 1, Groups E, F and G
Division2 ‘SEALS NOT REQUIRED’ , Temp. Class: T4, T5, T6 Encl Type 4x
Max. Process Temp.: T4; 120⬚C (248⬚F), T5; 100⬚C (212⬚F), T6; 85⬚C (185⬚F) CF1
Amb. Temp.: –40 to 80⬚C (–40 to 176⬚F)
Process Sealing Certification
Dual Seal Certified by CSA to the requirement of ANSI/ISA 12.27.01
No additional sealing required. Primary seal failure annunciation:
at the zero adjustment screw
Canadian Standards
Association (CSA) CSA Intrinsically safe Approval *1 *3 *4
Applicable standard: C22.2 No. 0, No. 0.4, No. 25, No. 30, No. 94, No. 142, No. 157
No. 213
Certificate: 1053843
Class I, Groups A, B, C and D Class II and III, Groups E, F and G
Encl Type 4x, Temp. Class: T4, Amb. Temp.: –40 to 60⬚C (–40 to 140⬚F) CS1
Vmax=30 V, Imax=165 mA, Pmax=0.9 W, Ci=22.5 nF, Li=730 ␮H
Process Sealing Certification
Dual Seal Certified by CSA to the requirement of ANSI/ISA 12.27.01
No additional sealing required. Primary seal failure annunciation:
at the zero adjustment screw
Combined CF1 and CS1 *1 *3 *4 CU1
IECEx Intrinsically safe, type n and Flameproof Approval *3 *4 *5
Intrinsically safe and type n
Applicable Standard: IEC 60079-0:2004, IEC 60079-11:1999, IEC 60079-15:2005,
IEC 60079-26:2005
Certificate: IECEx KEM 06.0007X
Ex ia IIC T4, Ex nL IIC T4 Enclosure: IP67
Amb. Temp.: –40 to 60⬚C (–40 to 140⬚F), Max. Process Temp.: 120⬚C (248⬚F)
IECEx Electrical Parameters: [Ex ia] Ui=30 V, Ii=165 mA, Pi=0.9 W, Ci=22.5 nF, Li=730 ␮H
SU2
Scheme [Ex nL] Ui=30 V, Ci=22.5 nF, Li=730 ␮H
Flameproof
Applicable Standard: IEC 60079-0:2004, IEC60079-1:2003
Certificate: IECEx KEM 06.0005
Ex d IIC T6...T4 Enclosure: IP67
Max.Process Temp.: T4;120⬚C (248⬚F), T5;100⬚C (212⬚F), T6; 85⬚C (185⬚F)
Amb.Temp.: –40 to 75⬚C (–40 to 167⬚F) for T4, –40 to 80⬚C (–40 to 176⬚F) for T5,
–40 to 75⬚C (–40 to 167⬚F) for T6
T07-2E.EPS

*1: Applicable for Electrical connection code 2, 7 and C (1/2 NPT female).
*2: Applicable for Electrical connection code 2, 4, 7, 9, C and D (1/2 NPT and M20 female).
*3: Applicable for Output signal code D and E.
For intrinsically safe approval, use the safety barrier certified by the testing laboratories (BARD-400 is not applicable).
*4: Lower limit of ambient temperature is –15˚C (5˚F) when /HE is specified.
*5: Applicable for Electrical connection code 2, 4, 7, C and D (1/2 NPT and M20 female).

 OPTIONAL SPECIFICATIONS
Item Description Code
Amplifier cover only P
Color change
Painting *1 Amplifier cover and terminal cover, Munsell 7.5 R4/14 PR
Coating change Epoxy resin-baked coating *2 X1
Exterior parts on the amplifier housing(name plates, tag plate, zero-adjustment screw,
316 SST exterior parts HC
stopper screw) will become 316 SST *3
Fluoro-rubber O-ring All O-rings of amplifier housing. Lower limit of ambient temperature: ⫺15⬚C (5⬚F) HE
Transmitter power supply voltage: 10.5 to 32 V DC (10.5 to 30 V DC for intrinsically
Lightning protector safe type, 9 to 32 V DC for Fieldbus communication type.) A
Allowable current: Max. 6000 A (1⫻40 ␮s), Repeating 1000 A (1⫻40 ␮s) 100 times
T08E-1.EPS

*1: Standard polyurethan painting can be used in acid atmosphere, whereas the epoxy resin-baked coating (Option code
X1) can be used in alkaline atmosphere. Anti-corrosion coating, the combination of polyurethan and epoxy resin-baked
coating, is available by special order as sea water, alkaline, and acid resistant.
*2: Not applicable for color change option.
*3: 316 or 316L SST. The specification is included in option code /E1.

All Rights Reserved. Copyright © 1997, Yokogawa Electric Corporation GS 01C21C01-00E July 01, 2011-00
<<Contents>> <<Index>> 9

Item Description Code


Degrease cleansing treatment K1
Oil-prohibited use Degrease cleansing treatment with fluorinated oil filling.
Operating temperature ⫺20 to 80⬚C K2

Degrease cleansing and dehydrating treatment K5


Oil-prohibited use
with dehydrating treatment Degrease cleansing and dehydrating treatment with fluorinated oil filling.
Operating temperature ⫺20 to 80⬚C K6

P calibration (psi unit) D1


bar calibration (bar unit) (See Table for Span
Calibration units*1 D3
and Range Limits.)
M calibration (kgf/cm2 unit) D4
Sealing treatment to Sealant(liquid silicone rubber) is coated on JIS SUS630 cover flange mounting nuts
SUS630 nuts Y
against stress corrosion cracking.
No serration*2 No serration work on the flange gasket surface (for ANSI flange only) Q
Diaphragm protection from sticky process fluid by FEP Teflon film attached with fluorinated oil.
Teflon film *3 Operation range: 20 to 120°C, 0 to 2 MPa (Not applicable for vacuum service). T

Update time: 0.125 sec or less


Fast response *12 Amplifier damping time constant: 0.1 to 64 sec in 9 increments F1
Response time (with min. damping time constant): max. 0.5 sec (excluding level unit)
Failure alarm down-scale *4 Output status at CPU failure and hardware error is –5%, 3.2 mA or less. C1
Failure alarm down-scale: output status at CPU failure and
C2
Output signal limits: hardware error is –5%, 3.2 mA or less.
NAMUR NE43 compliant *4 *13 3.8 mA to 20.5 mA Failure alarm up-scale: output status at CPU failure and
C3
hardware error is 110%, 21.6 mA or more.
Data configuration at factory *15 Description into “Descriptor” parameter of HART protocol CA
Stainless steel amplifier Amplifier housing material: SCS14A stainless steel
housing *5 (equivalent to SUS316 cast stainless steel or ASTM CF-8M) E1

Gold-plate *6 Inside of isolating diaphragms (fill fluid side) are gold plated, effective for hydrogen permeation.
A1
(process flange side)
Wired tag plate Stainless steel tag plate wired onto transmitter N4
High pressure side: Process flange, Block *7
For M03
Low pressure side: Cover flange
model
High pressure side: Process flange, Block *8 EJA210A M13
Low pressure side: Cover flange, Process connector
Mill Certificate
High pressure side: Process flange, Block, Pipe, Base *7
For M04
Low pressure side: Cover flange
model
High pressure side: Process flange, Block, Pipe, Base *8 EJA220A
Low pressure side: Cover flange, Process connector M14
(Flange rating) (Test Pressure)
JIS 10K 2 MPa {20 kgf/cm2 } T31
Pressure test/Leak test JIS 20K 5 MPa {50 kgf/cm2 } T32
Certificate *14 ANSI/JPI Class 150 3 MPa {29.8 kgf/cm2 } Nitrogen (N2) Gas *11 T36
ANSI/JPI Class 300 7.7 MPa {77 kgf/cm2 } *9 Retention time: 10 minutes T37
ANSI/JPI Class 300 7 MPa {70 kgf/cm2 } *10 T38
T08E-2.EPS

*1: The unit of MWP (Max. working pressure) on name plate of a housing is the same unit as specified by Optional code D1,
D3, and D4.
*2: This item cannot be applied to model EJA210A Wetted parts material code H and T, whose gasket contact surface are
not serrated as standard specifications.
*3: Teflon film can only be specified for model EJA210A.
*4: Applicable for Output signal code D and E. The hardware error indicates faulty amplifier or capsule.
When combining with Option code F1, output status for down-scale is –2.5%, 3.6 mA DC or less.
*5: Applicable for Electrical connection code 2, 3, 4, A, C and D. Not applicable for Option code P and X1.
*6: Applicable for Wetted parts material code S and W .
Consult Yokogawa in case gold-plated disphragm is required for low pressure side.
*7: Applicable for Low Pressure Side Process connection code 0 and 5.
*8: Applicable for Low Pressure Side Process connection code 1, 2, 3, and 4.
*9: Applicable for model EJA210A.
*10: Applicable for model EJA220A.
*11: Pure nitrogen gas is used for oil-prohibited use (Option code K1, K2, K5, and K6 ).
*12: Applicable for Output signal code D and E. Write protection switch is attached for Output code E.
*13: Not applicable for Option code C1.
*14: The unit on the certificate is always MPa regardless of selection of option code D1, D3, or D4.
*15: Applicable for Output signal code E.

All Rights Reserved. Copyright © 1997, Yokogawa Electric Corporation GS 01C21C01-00E Oct. 01, 2008-00
<<Contents>> <<Index>> 10
 DIMENSIONS
 Model EJA210A
Unit: mm (approx.inch)
174 (6.85) 30 (1.18)
110 (4.33)
External indicator
conduit connection 133 (5.24) 72 Conduit Zero 35
connection adjustment
(Optional) (2.83) (1.38)

25 Internal Terminal side


(0.98) indicator ø78
t (Optional) (3.07)
162 146
(6.38) (5.75)
Shrouding bolt *3 Ground
terminal
øD øC øg ød *1
Process
connection Vent plug

46 Drain plug
Process
(1.81) connector n- øh
(Optional) 54 37 *2
Process flange (2.13) (1.46)

*1: Indicates inside diameter of gasket contact surface.


*2: When Optional code K1, K2, K5, or K6 is selected, add 15 mm(0.59 inch) to the value in the figure.
*3: Applicable only for ATEX and IECEx Flameproof type.

Flange size: 3-inch (80 mm)


Flange Nominal Bolt Holes
Diameter and øD øC øg ød t
Rating No.(N) Dia.(øh)
JIS 10K 185(7.28) 150(5.91) 130(5.12) 90(3.54) 18(0.71) 8 19(0.75)

JIS 20K 200(7.87) 160(6.30) 130(5.12) 90(3.54) 22(0.87) 8 23(0.91)

ANSI Class150 190.5(7.50) 152.4(6.00) 130(5.12) 90(3.54) 23.9(0.94) 4 19.1(0.75)

ANSI Class300 209.6(8.25) 168.1(6.62) 130(5.12) 90(3.54) 28.5(1.12) 8 22.4(0.88)

JPI Class150 190(7.48) 152.4(6.00) 130(5.12) 90(3.54) 24(0.94) 4 19(0.75)

JPI Class300 210(8.27) 168.1(6.62) 130(5.12) 90(3.54) 28.5(1.12) 8 22(0.87)

DIN PN 10/16 200(7.87) 160(6.30) 130(5.12) 90(3.54) 20(0.79) 8 18(0.71)

DIN PN 25/40 200(7.87) 160(6.30) 130(5.12) 90(3.54) 24(0.94) 8 18(0.71)

Flange size: 2-inch (50 mm)


Flange Nominal Bolt Holes
Diameter and øD øC øg ød t
Rating No.(N) Dia.(øh)
JIS 10K 155(6.10) 120(4.72) 100(3.94) 61(2.40) 16(0.63) 4 19(0.75)

JIS 20K 155(6.10) 120(4.72) 100(3.94) 61(2.40) 18(0.71) 8 19(0.75)

ANSI Class150 152.4(6.00) 120.7(4.75) 100(3.94) 61(2.40) 19.1(0.75) 4 19.1(0.75)

ANSI Class300 165.1(6.50) 127(5.00) 100(3.94) 61(2.40) 22.4(0.88) 8 19.1(0.75)

JPI Class150 152(5.98) 120.6(4.75) 100(3.94) 61(2.40) 19.5(0.71) 4 19(0.75)

JPI Class300 165.1(6.50) 127(5.00) 100(3.94) 61(2.40) 22.5(0.89) 8 19(0.75)

DIN PN 10/16 165(6.50) 125(4.92) 100(3.94) 61(2.40) 18(0.71) 4 18(0.71)

DIN PN 25/40 165(6.50) 125(4.92) 100(3.94) 61(2.40) 20(0.79) 4 18(0.71)


F03E.EPS

All Rights Reserved. Copyright © 1997, Yokogawa Electric Corporation GS 01C21C01-00E Mar. 23, 2006-00
<<Contents>> <<Index>> 11
 Model EJA220A
Unit: mm (approx.inch)
174 (6.85) 30 (1.18)
110 (4.33)
External indicator
conduit connection 133 (5.24) 72 Conduit Zero 35
connection adjustment
(Optional) (2.83) (1.38)

Internal Terminal side


indicator
ø78
(Optional) (3.07)
162 146
(6.38) (5.75)
Shrouding bolt *2 Ground
terminal
øD øC øg øA
Process
connection Vent plug
46
Drain plug
(1.81) Process
connector n- øh
(Optional) 54 37 *1
t Process flange
(2.13) (1.46)
25 (0.98)
X2 *1: When Optional code K1, K2, K5, or K6 is selected,
add 15 mm(0.59 inch) to the value in the figure.
*2: Applicable only for ATEX and IECEx Flameproof type.
Flange size: 4-inch (100 mm)
Flange Nominal Bolt Holes
Diameter and øD øC øg øA t
Rating No.(N) Dia.(øh)

JIS 10K 210(8.27) 175(6.89) 155(6.10) 96±0.5(3.78) 18(0.71) 8 19(0.75)

JIS 20K 225(8.86) 185(7.28) 155(6.10) 96±0.5(3.78) 24(0.94) 8 23(0.91)

ANSI Class150 228.6(9.00) 190.5(7.50) 155(6.10) 96±0.5(3.78) 23.9(0.94) 8 19.1(0.75)

ANSI Class300 254(10.00) 200(7.87) 155(6.10) 96±0.5(3.78) 31.8(1.25) 8 22.4(0.88)

JPI Class150 229(9.02) 190.5(7.50) 155(6.10) 96±0.5(3.78) 24(0.94) 8 19(0.75)

JPI Class300 254(10.00) 200.2(7.88) 155(6.10) 96±0.5(3.78) 32(1.26) 8 22(0.87)

DIN PN 10/16 220(8.66) 180(7.09) 155(6.10) 96±0.5(3.78) 20(0.79) 8 18(0.71)

DIN PN 25/40 235(9.25) 190(7.50) 155(6.10) 96±0.5(3.78) 24(0.94) 8 22(0.87)

Flange size: 3-inch (80 mm)


Flange Nominal Bolt Holes
Diameter and øD øC øg øA t
Rating No.(N) Dia.(øh)

JIS 10K 185(7.28) 150(5.91) 130(5.12) 71±0.5(2.80) 18(0.71) 8 19(0.75)

JIS 20K 200(7.87) 160(6.30) 130(5.12) 71±0.5(2.80) 22(0.87) 8 23(0.91)

ANSI Class150 190.5(7.50) 152.4(6.00) 130(5.12) 71±0.5(2.80) 23.9(0.94) 4 19.1(0.75)

ANSI Class300 209.6(8.25) 168.1(6.62) 130(5.12) 71±0.5(2.80) 28.5(1.12) 8 22.4(0.88)

JPI Class150 190(7.48) 152.4(6.00) 130(5.12) 71±0.5(2.80) 24(0.94) 4 19(0.75)

JPI Class300 210(8.27) 168.1(6.62) 130(5.12) 71±0.5(2.80) 28.5(1.12) 8 22(0.87)

DIN PN 10/16 200(7.88) 160(6.30) 130(5.12) 71±0.5(2.80) 20(0.79) 8 18(0.71)

DIN PN 25/40 200(7.87) 160(6.30) 130(5.12) 71±0.5(2.80) 24(0.94) 8 18(0.71)

Diaphragm Extension Length Code X2

2 1.97 inch (50 mm)

4 3.94 inch (100 mm)

6 5.91 inch (150 mm)


F04E.EPS

All Rights Reserved. Copyright © 1997, Yokogawa Electric Corporation GS 01C21C01-00E Mar. 23, 2006-00
<<Contents>> <<Index>> 12
● Terminal Configuration ● Terminal Wiring
SUPPLY +
– Power supply and output terminal

+
CHECK – External indicator(ammeter) terminal*1

Communication Ground terminal


Terminals(BT200 etc.) SUPPLY CHECK CHECK METER
Connection hook Connection hook*1 *1: When using an external indicator or a check meter,
the internal resistance must be 10 ⍀ or less.
Not available for Fieldbus communication(Output signal
code F and G). F05E.EPS

 SELECTION GUIDE
Measurement Span Maximum Working Pressure
Application Type Model Capsule
kPa inH2O MPa psi
L 0.5 to 10 2 to 40 16*4 2250*4
Differential M 1 to 100 4 to 400 16 2250
Pressure Traditional-Mounting*1 EJA110A
H 5 to 500 20 to 2000 16 2250
V 0.14 to 14MPa 20 to 2000 psi 16 2250
L 1 to 10 4 to 40 3.5 500
Flow Integral Orifice EJA115 M 2 to 100 8 to 400 14 2000
H 20 to 210 80 to 830 14 2000
Differential Pressure Extended EJA118N M 2.5 to 100 10 to 400
& Liquid Level Flush EJA118W 25 to 500 Based on Flange Rating
H 100 to 2000
with Remote Seals Combination EJA118Y
Draft Range Traditional-Mounting*1 EJA120A E 0.1 to 1 0.4 to 4 50 kPa 7.25
Differential Pressure Traditional-Mounting*1 M 1 to 100 4 to 400 32 4500
& Liquid Level EJA130A
H 5 to 500 20 to 2000 32 4500
Liquid Level, Closed Flush EJA210A M 1 to 100 4 to 400
20 to 2000 Based on Flange Rating
or Open Tank Extended EJA220A H 5 to 500
L 0.67 to 10*2 2.67 to 40*2 10 kPa*2 40 in H2O*2
Absolute (vacuum) 130 kPa*2
Pressure Traditional-Mounting*1 EJA310A M 1.3 to 130*2 0.38 to 38 inHg*2 18.65*2
A 0.03 to 3 MPa*2 4.3 to 430 psi*2 3000 kPa*2 430*2
A 0.03 to 3 MPa 4.3 to 430 psi 3 430
Gauge Pressure Traditional-Mounting*1 EJA430A 0.14 to 14 MPa 20 to 2000 psi 14 2000
B
Gauge Pressure Extended EJA438N A 0.06 to 3 MPa 8.6 to 430 psi Based on Flange Rating
with Remote Seal B 0.46 to 7 MPa 66 to 1000 psi
Gauge Pressure A 0.06 to 3 MPa 8.6 to 430 psi
Flush EJA438W 66 to 2000 psi Based on Flange Rating
with Remote Seal B 0.46 to 14 MPa
C 5 to 32 MPa 720 to 4500 psi 32 4500
High Gauge Traditional-Mounting*1 EJA440A 5 to 50 MPa 720 to 7200 psi
D 50 7200
A 10 to 200 1.45 to 29 psi 200 kPa 29
Absolute & Gauge EJA510A B 0.1 to 2 MPa 14.5 to 290 psi 2 290
Direct-Mounting
Pressure*3 EJA530A C 0.5 to 10 MPa 72.5 to 1450 psi 10 1450
D 5 to 50 MPa 720 to 7200 psi 50 7200
T09E.EPS

*1: Traditional-mounting is 1/4 - 18 NPTF process connections ( 1/2 - 14 NPTF with process adapters ) on 2-1/8" centers.
*2: Measurement values in absolute.
*3: Measurement values in absolute for EJA510A.
*4: When combined with Wetted parts material code H, M, T, A, D, and B, the value is 3.5 MPa (500 psi).
< Ordering Information > “” 4. Display scale and units (for transmitters equipped
Specify the following when ordering with integral indicator only)
1. Model, suffix codes, and optional codes Specify either 0 to 100 % or engineering unit scale
2. Calibration range and units: and ‘Range and Unit’ for engineering units scale:
1) Calibration range can be specified with range value Scale range can be specified with range limit
specifications up to 5 digits specifications up to 5 digits (excluding any decimal
(excluding any decimal point) for low or high range point) for low or high range limits within the range of
limits within the range of -32000 to 32000. -19999 to 19999.
2) Specify only one unit from the table, ‘Settings when 5. Tag Number (if required)
shipped.’
3. Select linear or square root for output mode and
display mode.
Note: If not specified, the instrument is shipped in
normal operation mode.

All Rights Reserved. Copyright © 1997, Yokogawa Electric Corporation GS 01C21C01-00E June 01, 2007-00
Subject to change without notice.

You might also like