The AQ-G257 generator protection IED provides complete protection for large synchronous machines including integrated differential protection. It supports up to 9 optional I/O or communication cards for extensive monitoring and control. Thermal protection is available through connections for up to 16 RTD sensors. The device communicates using various protocols such as IEC 61850.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
3K views4 pages

XXXXXXXXXXXXXXXX

The AQ-G257 generator protection IED provides complete protection for large synchronous machines including integrated differential protection. It supports up to 9 optional I/O or communication cards for extensive monitoring and control. Thermal protection is available through connections for up to 16 RTD sensors. The device communicates using various protocols such as IEC 61850.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

AQ-G257 Generator protection IED

AQ-G257 Generator protection IED

The AQ-G257 generator protection IED is well suited for


large machines requiring complete generator protection
and differential protection. Up to 9 optional I/O or
communication cards are available for extensive
monitoring and control applications. Up to 16 RTD signals
can be connected for thermal alarming and tripping. The
AQ-G257 communicates using various protocols including
IEC 61850 substation communication standard.

Highlights

Complete synchronous machine protection


Integrated differential protection
Power measurements up to class 0.2S

Technical Data

PROTECTION
Generator/transformer differential (87G/T)

Three-phase overcurrent, 2 stages INST, DT or IDMT (50/51)

Earth-fault (sensitive), 2 stages INST, DT or IDMT (50/51N)

Harmonic overcurrent / inrush blocking, 4 stages INST, DT or IDMT (50/51H, 68)

Current unbalance / broken conductor, 2 stages INST, DT or IDMT (46/46R/46L)

High/low impedance restricted earth fault / cable end differential * (87N)

Directional overcurrent, 4 stages INST, DT or IDMT (67)

Directional (sensitive) earth-fault, 4 stages INST, DT or IDMT (67N)

Overvoltage, 2 stages INST, DT or IDMT (59)

Undervoltage, 2 stages INST, DT or IDMT (27)

Zero sequence overvoltage, 2 stages INST, DT or IDMT (59N)

Positive/Negative sequence overvoltage, 2 stages INST, DT or IDMT (59N/47)


AQ-G257 Generator protection IED

Over/under frequency, 4 stages INST or DT (81O/81U)

Rate of change of frequency, 4 stages INST or DT or IDMT (81R)

Loss of field (40)

Voltage restrained overcurrent (51V)

Field ground / 100% stator earth-fault (64S)

Rotor earth-fault protection (64R)

Over/Under/Reverse power (32/37/32R)

Generator thermal overload (49G/49RTD)

Under impedance (21U)

Volts per hertz (24)

Out of step / pole slip (78)

Breaker failure protection (50BF/52BF)

Arc protection (option) (50ARC/50NARC)

CONTROL
Controllable objects: 10

Synchro-check (25)

8 setting groups

MEASURING AND MONITORING


Phase and residual currents (IL1, IL2, IL3, I01, I02)

Voltage measurements (UL1-UL3, U12-U31, U0, SS)

Current and voltage THD and harmonics (up to 31st)

Frequency (f)

Power (P, Q, S, pf)

Energy (E+, E-, Eq+, Eq-)

Circuit breaker wear (CBW)

Disturbance recorder (3.2 kHz)

Current transformer supervision (CTS)

Fuse failure (VTS)

Trip circuit supervision (TCS)


Event recording
AQ-G257 Generator protection IED

Non-volatile disturbance records: 100

Non-volatile event records: 15000

I/0
Current inputs: 10

Voltage inputs: 4

Digital inputs: 3 (standard)

Output relays: 5+1 (standard)


Options (11 slots)
Digital inputs optional: +8/16/24/32/40/48/56/64/72

Digital outputs optional: +5/10/15/20/25

Arc protection (12 sensors +2xHSO +BI)

2 x mA input + 6-8 x RTD input (max 2 cards)

Communication media (specified below)

COMMUNICATION
RJ 45 Ethernet 100Mb (front standard)

RJ 45 Ethernet 100Mb and RS 485 (rear standard)

Double LC Ethernet 100Mb (option)

RS232 + serial fibre PP/PG/GP/GG (option)


Communication protocols
IEC 61850

IEC 608705103/101/104

Modbus RTU, Modbus TCP/IP

DNP 3.0, DNP 3.0 over TCP/IP

SPA
AQ-G257 Generator protection IED