Soyal Um721h
Soyal Um721h
SOYAL
®
Contents
AR-321H [Metal Case]
1 Product 2 User Guide 3 Terminal Cables 4 Tools 5 Water proof Strip
d x2
P1 P2 P3 P4
AR-721H
1 Product 2 User Guide 3 Terminal Cables 4 Tools
f x2
P1 P2 P3 P4
c x2
P1 P2
e x1
P3 P4
A. B. C. D.
AR-725H
1 Products 2 User Guide 3 Terminal Cables 4 Tools
P1 P2 f x2
A1. E. F. P3 P4
AR-725X
1 Products 2 Tools
a x2 e x1
b x2
c x2
A2. A3. B. C. G. H. D.
AR-757H
1 Product 2 User Guide 3 Terminal Cables 4 Tools
f x2
P1 P2 P3 P4 P6
Parts Description
a. b. c. d.
Button Head Pozidriv Button Head Pozidriv Flat Head Cap Philips Flat Head Cap Philips
Tapping Screw: M3x10 Slotting Screw: 2.5x10 Tapping Screw: 4x19.1 Tapping Screw: 4x38
e. f.
Security Torx Screw: Flat Head Hex Socket
M3.5x15 Screw: M3x8
Access Controller
Metal Case / Illuminated Touch-panel V090810
Installation
AR-321H [Metal Case]
3
Pull the cables from the square hole of the mounting plate.
Use a screwdriver to screw the mounting plate onto the wall.
Attach the water proof strip to the body, then connect the terminal cables to the body and attach the
body to the mounting plate.
2 Use the Allen key and screws (accessories supplied) to assemble the body onto the mounting plate.
1
4
Turn on the power, and LED will light and beep will sound.
AR-721H
Pull the cables from the square hole of the mounting plate.
Use a screwdriver to screw the base onto the wall.
Connect the terminal cables to the body and attach the body to the mounting plate.
4 Assemble the covers with the Allen key and screws (accessories supplied).
Turn on the power and LED will light and beep will sound.
AR-725H [Illuminated Touch-panel]
AR-725H-M
Pull the cables from the square access hole of the mounting plate C.
Use a screwdriver to screw the metal plate C onto the wall.
A. A. 7
3
A. B. C.
Take off the plastic mounting plate B from the body A, and pull the cables
2
C. A. C.
B. through the access hole of C and B, then connect to the body A.
6
Assemble plate B with the body A, and embed the water proof strip D
4
1 B. 5 onto the plastic side frame.
d.
c.
8 Assemble the body A onto the mounting plate C with the Allen key and
D.
screws (accessories supplied).
Turn on the power and LED will light and beep will sound.
AR-725H
F.
E. Use a screwdriver to screw the base F onto the wall.
1 F. A1. 2 Attach the water proof gasket to the body A1, and pull the cables
3
from the square hole of the base F, and connect to the body A1.
Assemble the body A1 with the base F.
4
Screw A1 and F tight with the Allen key and screws (accessories
e. supplied).
5
Turn on the power and LED will light and beep will sound.
AR-725X
Put on G, and attach A1 onto the plastic plate A3, and screw it with
A1. A1.+A3. D.
2
H.
the Allen key and screws (accessories supplied).
A3.
1 A2. Put the ring O on the metal frame, and put them together onto the
b.
4 reader A1+A3, and screw them and buckle up the 4 buckles on the
a.
back.
e.
G. 3 5 Embed the water proof strip D onto the frame side of the base.
Following by the install process of AR-725H-M.
AR-757H
Pull the cables from the square hole of the mounting plate.
Use a screwdriver to screw the base onto the wall.
Connect the terminal cables to the body and attach the body to the mounting plate.
4 Assemble the covers with the Allen key and screws (accessories supplied).
Turn on the power and LED will light and beep will sound.
Notice
1.Tubing: The communication wires and power line should NOT be bound in the same conduit or tubing.
2.Wire selection: Use AWG 22-24 Shielded Twist Pair to avoid star wiring.
3.Power supply: Don’t equip reader and lock with the same power supply. The power for reader may be unstable when the lock is activating, that may make the
reader malfunction.
The standard installation: Door relay and lock use the same power supply, and reader use independent power supply.
AR-321H/AR-721H/
SOYAL
®
Connector Table
AR-321H [Metal Case]
125kHz Cable: P1
P4 P5 Wire Application Pin Color Description
Door Relay 1 Blue White (N.O.) DC24V1Amp
P3 P2
2 Purple White (N.C.) DC24V1Amp
P1 Common-COM-Point 3 White (COM) DC24V1Amp
Door Sensor 4 Orange Negative Trigger Input
Exit Switch 5 Purple Negative Trigger Input
AR-721H Alarm 6 Gray N.O. or N.C. shift by JP1 jumper and Shared Com with Door Relay
125kHz 13.56MHz RelayPower 7 Thick Red DC Power 12V
P3 8 Thick Black DC Power 0V
P2
P1 P1
P2 Cable: P2
Wire Application Pin Color Description
P4
P5
P4 P3 Wiegand 1 Thin Blue Wiegand DAT:1 Input
P5 2 Thin Green Wiegand DAT:0 Input
Beeper 3 Pink Beeper Output 5V/100mA, Low
AR-725H [Illuminated Touch-panel]
LED 4 Brown LED Green Output 5V/20mA, Max
125kHz 13.56MHz 5 Yellow LED Red Output 5V/20mA, Max
P2 P3 P5 P2
Cable: P3
P1 P1
P5
Wire Application Pin Color Description
P4 P3 Networking 1 Thick Green RS-485(B-)
P4
Module 2 Thick Blue RS-485(A+)
AR-757H
Cable: P4 Contact Rating: 1A 125VAC/24VDC
125kHz Main Board 13.56MHz Main Board
Wire Application Pin Color Description
Tamper Switch 1 Red N.C.
P2 P2
P6 P6 2 Orange COM
3 Yellow N.O.
P4 P4 ※After S/N: 0706-XXXXXX
Wiring Diagram
AR-321H to Electric Bolt
Connector Connector to Magnet Lock
12V 12V 12V 12V
POWER POWER
GND GND GND GND
12VDC 12VDC
Exit Switch
E Magnet Lock
Electric Bolt
P1 P1
N.O. 1 1
2 N.C. 2
COM 3 COM 3
4 4
PB 5 PB 5
6 6
N.O. N.O.
12V 7 12V 7
GND GND
GND 8 GND 8
Controller EXIT Controller EXIT
12V 12V
POWER POWER
GND Push Button GND Push Button
12VDC 12VDC
Access Controller
Metal Case / Illuminated Touch-panel V090810
P1 P1
N.O. 1 1
N.C.
2 2
N.O.
COM 3 3
COM
4 Door Sensor 4
CTL
PB 5 5
12V
6 ALM 6
N.O.
12V 7 12V 7 Relay Outpot Module
GND
GND 8 GND 8
Controller EXIT Controller
12V 12V
POWER POWER
GND Push Button GND Door Sensor
12VDC 12VDC
AR-321H to Reader
Connector Connector to Networking
GND
Converter POWER
A+ 12V
Reader Controller B- 12VDC
P1 Door No. 1 Door No. 8
WG 1 1 WG 1 1
WG 0
Node ID 001
WG 0 2 2 B- 1 B- 1
BZ 3 BZ 3
AR-716E P3 A+ P3 A+
2 2
GLED 4 GLED 4
RLED 5 RLED 5 Host
B- Controller Controller
A+
12V P2 6
12V B-
GND 7 CH1
GND A+
8
B-
CH2
A+
GND
POWER Controller Controller
12V
12VDC Controller
B- 1 B- 1
B- 1
P3 P3
A+ 2 A+ 2
P3
A+ 2
Node ID 254 Door No. 9 Door No. 16
Operation process
A. Enter/ Exit Program Mode
Enter the program mode
Input 123456 or PPPPPP
[e.g.] The Default Value= 123456, if already changed the Master Code= 876112, input 876112 → program mode accessed
Exit the program mode
Input
Master Code modification
Access programming mode → 09 PPPPPPRRRRRR [Input the 6-digit new master code twice.]
[e.g.] Set the Master code to be 876112, input 123456 → 09 876112876112
B. Chang the Node ID of Reader
Access programming mode → 00 NNN [Node ID: 001~254]
C.Set up M4/M6/M8
Access programming mode → 04 N [N=4/6/8]
D. Set up the password
M4/M8: Individual pass code
Card or PIN: Access programming mode → 12 UUUUU PPPP [i.e. User address: 00001 and pass code: 1234, input 12 00001 1234 ]
Card and PIN: Access programming mode → 13 UUUUU PPPP [i.e. User address: 00001 and pass code: 1234, input 13 00001 1234 ]
M6: Public pass word
PIN only: Access programming mode → 15 PPPP [Input 4-digit pass code, default value: 4321]
Card and PIN: Access programming mode → 17 PPPP [Input 4-digit pass code, default value: 1234]
E. Dual Door Open(M4/M8)
Requires indoor reader and outdoor readers.
Access programming mode → 28 064 [064= Dual Door Open]
F. Anti-pass-back(M4/M8)
Usually, anti-pass-back is commonly applied to parking areas in order to prevent from multi-entry with one card at a time, or to situations need
access and exit monitor.
Reader enable
Access programming mode → 20 128 [128= Anti-pass-back enable.]
Card enable
Access programming mode → 26 SSSSS EEEEE N
[SSSSS= User address start; EEEEE= User address end; N=0(control)/ 1(Not control)/ 2(reset)]
[e.g.] User address from 00152 to 00684 enable the anti-pass-back function: 26 00152 00684 0
G. Auto Open Time Zone
Door will keep open after the first flashing card.There are 2 time zones supported when Stand-Alone, and 64 time zones when it is on network.
Enable/Disable auto open zone
Access programming mode → 20 004 [004= enable Auto-Open Time Zone; 000= disable Auto-Open Time Zone]
Enable/Disable auto open door without presenting card
Access programming mode → 24 001 [001= enable Auto-Open Time Zone; 000= disable Auto-Open Time Zone]
Set up open time
Access programming mode → 08 N HHMMhhmm FFFFFFF
N: 2 sets of auto-open zone (N=0=1st set; N=1=2nd set)
HHMMhhmm=Staring time to ending time (e.g. 08301200=08:30 to 12:00)
FFFFFFF= 7 days of week (Sat/Fri/Thu/Wed/Tue/Mon/Sun) (F= 0: disable; 1: enable)
[e.g.] To set the second time zone as 9:30 AM to 4:20 PM, Monday, Wednesday and Friday: 08 1 09301612 0101010 → Done
H. Lift control
Connect with AR-401RO16B to control which floors the user will be able to access.
Enable Please refer to below floor chart
Access programming mode → 24 002 [002= enable lift control] Floor/ Stop
Set
Single floor F F F F F F F F
Access programming mode → 27 UUUUU FF 0 8 7 6 5 4 3 2 1
UUUU=User Address FF=Floor number (01~32 floor/stop) 1 16 15 14 13 12 11 10 9
[e.g.] User address NO. 45, allow to access the 24th floor: 27 00045 24 2 24 23 22 21 20 19 18 17
Multi floors 3 32 31 30 29 28 27 26 25
Access programming mode → 21 UUUUU S FFFFFFFF
[UUUUU=User address S: 4 sets of lift control (Input: 0~3) FFFFFFFF: 8 floors/stop setting (F=0=Disable, F=1=Enable)
[e.g.] User address NO. 45, only to the 6th and the 20th floor:
Access programming mode → 21 00168 0 00100000 → 21 00168 2 00001000
Access Controller
Metal Case / Illuminated Touch-panel V090810
Command List
Function Command Description Mode
Entering programming mode PPPPPP PPPPPP=Master Code, default value=123456 M4/M6/M8
Exiting programming mode M4/M6/M8
Exiting programming mode and enabling arming status M4/M6/M8
Node ID setting 00 NNN NNN=Node ID M4/M8
(Connecting to 716E,or total unit is < 254) range: 001~254
Node ID setting 00 NNN VVV nnn NNN=Node ID of Access Controller, VVV=Virtual 716E Node ID, M4/M8
(Connecting to PC directly without via 716E and > 254) nnn=Door number; range:001~254
Mifare tag / card format (Optional) 01 N N: 0=ISO14443A; 1=ISO14443B; 2=ISO15693; M4/M8
Door relay time setting 02 TTT TTT=Door relay time 000= Output constantly M4/M6M8
001~600=1~600 sec.
601~609=0.1~0.9 sec.
Alarm relay time setting 03 TTT TTT=Alarm relay time 001~600=1~600 sec. M4/M6/M8
Control mode setting 04 N N=Mode 4=Mode4;6=Mode6;8=Mode8 M4/M6/M8
Arming delay time setting 05 TTT TTT=Arming delay time 001~600=1~600 sec. M4/M6/M8
Alarm delay time setting 06 TTT TTT=Alarm delay time 001~600=1~600 sec. M4/M6/M8
Master card setting 07 SSSSS EEEEE SSSSS-EEEEE=00000-01023 (00000-03071 for AR-725H); M4/M8
Set a sequence of cards as "read and access" 11 SSSSS EEEEE SSSSS=Starting card number M6
Active the suspended cards 11 SSSSS EEEEE SSSSS=Starting user address M4/M8
Set the cards as Card mode OR PIN mode 12 UUUUU PPPP Access mode: Card or PIN; UUUUU=user address; M4/M8
Card number modification 16 UUUUU SSSSSCCCCC UUUUU= User address; SSSSS=5-digit site code; M4/M8
M4/M8: Arming pass code setting 17 PPPP PPPP=4-digit pass code ( default value=1234; disable Arming PWD=0000) M4/M6/M8
M6: Public PIN setting (Card and PIN) P.S. Arming PWD code will be unavailable and become a public PIN at access mode “Card PIN” and of M6
Door open waiting time 18 TTT TTT=Door open waiting time: 001~600=1~600 sec.; default value: 15 sec. M4/M6/M8
Set the card by induction(M4/M8) 19 UUUUU QQQQQ UUUUU=User address; M4/M8
QQQQQ=Card quantity(00001=Continuously inducting)
Reader additional setting 20 DDD Please refer to function default value for details. M4/M6/M8
Lift control setting: multi-doors 21 UUUUU S FFFFFFFF UUUUU=User address, S=4 sets of lift control(0~3); FFFFFFFF=8 assigned floor M4/M8
(F=0: Disable, 1: Enable)
Add/Delete tag by induction (M6 only) 22 N N=0(Delete tag); N=1(Add tag) M6
AR-401ROsite number dip switch 23 NNN TTT NNN=site number, TTT= relay time: 000~600=1~600 sec. M4/M8
Reader parameter setting 24 DDD Please refer to function default value for details. M4/M6/M8
Real time clock setting 25 YYMMDDHHmmss YYMMDDHHmmss: Year/ Month/ Day/ Hour/ Min./ Sec. M4/M6/M8
Anti-pass-back (Enable user) 26 SSSSS EEEEE N SSSSS=Starting user address; EEEEE=Ending user address; M4/M8
N=0/Enable; N=1/Disable; N=2/Initial
Single floor setting 27 UUUUU FF UUUUU=User Address; FF=Floor (01~32 floor) M4/M8
Dual door control/ Active or inactive arming for force open 28 NNN Please refer to function default value for details. M4/M6/M8
Delete all tags 29 29 M4/M6/M8
Access Controller
Metal Case / Illuminated Touch-panel V090810