0% found this document useful (0 votes)
22 views

Static Load On Building:: I) Dead Load: Unit Wt. of Materials

The document discusses static load considerations for building design, including: 1) Dead loads from building materials like concrete, brick, plaster, and floor finishes. Wall load calculations are provided for various wall types. 2) Live load requirements from Indian Standard IS 875 part II, including imposed floor loads of 2 kN/m^2 for rooms, 3 kN/m^2 for staircases, and roof live loads of 2 kN/m^2 if sloped less than 10 degrees. Minimum floor finishing loads are also specified.

Uploaded by

Urusha Shrestha
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
22 views

Static Load On Building:: I) Dead Load: Unit Wt. of Materials

The document discusses static load considerations for building design, including: 1) Dead loads from building materials like concrete, brick, plaster, and floor finishes. Wall load calculations are provided for various wall types. 2) Live load requirements from Indian Standard IS 875 part II, including imposed floor loads of 2 kN/m^2 for rooms, 3 kN/m^2 for staircases, and roof live loads of 2 kN/m^2 if sloped less than 10 degrees. Minimum floor finishing loads are also specified.

Uploaded by

Urusha Shrestha
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

STATIC LOAD ON BUILDING:

i) DEAD LOAD:
Unit wt. of Materials:
As per IS 875 Part I:
Reinforced Cement Concrete= 25 KN/m³
Local Brick Masonry= 18.85 KN/m³ (1920 Kg/m³)
Finishing Works:
Cement Plaster= 20.40 KN/m³
Screeding= 20.40 KN/m³
Marble Floor Finishing= 26.70 KN/m³
Dead Load due to the walls on the beam of the Building:
Dimensions
Total
S.No Depth (D) Finishing Self
Building Components Width (B) Unit Units Remarks
. or Height Load Weight
mm Weight
(H) mm
A 9"outer wall without opening 230 2033 1.04 8.81 9.85 KN/m
B 9" outer wall with opening 230 2033 0.88 7.49 8.37 KN/m 15% opening wall
C 9" inner wall with opening 230 2033 0.73 6.17 6.90 KN/m 30% opening
D 9" inner wall with opening 230 2033 0.62 5.29 5.91 KN/m 40% opening wall
E 4" inner wall without opening 100 2033 1.04 3.83 4.87 KN/m
F 4" Inner wall with opening 100 2033 0.93 3.26 4.19 KN/m 15% opening wall
G 4" Inner wall with opening 100 2033 0.73 2.68 3.41 KN/m 30% opening wall
H 4" parapet wall 100 1000 0.51 1.89 2.40 KN/m

ii) LIVE LOAD:


Imposed Floor load For Residential Building:
As per IS 875 part II:
Live Load Intensity for rooms with out separate storage= 2 KN/m²
Live Load for Staircase,Corridors,Passages and Lobbies= 3 KN/m²
Live Load for Bath and Toilet Rooms = 2 KN/m²
Live Load for Balconies = 3 KN/m²
Live Load for flat , sloping or curved Roof with slope upto 10
degree and Access Provided= 2.0 KN/m²
Live Load Intensity for overhead tank storage= 3.5 KN/m²
Floor Finising for toilet. 2.25 KN/m² Minimum loading for Floor Finishing
Floor Finising for Landing, passages, balconys etc= 1.2KN/m " " " "
Floor Finising for Staircase (with steps)= 3 KN/m² " " " "
Floor Finising for Rooms etc= 1.0KN/m " " " "