Open navigation menu
Close suggestions
Search
Search
en
Change Language
Upload
Sign in
Sign in
Download free for days
0 ratings
0% found this document useful (0 votes)
793 views
4 pages
Problems
Power System Protection
Uploaded by
Abdul Sami
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content,
claim it here
.
Available Formats
Download as PDF or read online on Scribd
Download
Save
Save Problems For Later
Share
0%
0% found this document useful, undefined
0%
, undefined
Print
Embed
Report
0 ratings
0% found this document useful (0 votes)
793 views
4 pages
Problems
Power System Protection
Uploaded by
Abdul Sami
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content,
claim it here
.
Available Formats
Download as PDF or read online on Scribd
Carousel Previous
Carousel Next
Download
Save
Save Problems For Later
Share
0%
0% found this document useful, undefined
0%
, undefined
Print
Embed
Report
Download
Save Problems For Later
You are on page 1
/ 4
Search
Fullscreen
iL Sed ssh ina 1! ~LitounpghousE burr aa 7 (9883; SL! cis)Example 22.1. A star-conmected, 3-phase, 10-MVA, 6:6 kV alternator has a per phase reac- tance of 10%. It is protected by Merz-Price circulating-current principle which is set to operate for fault currents not less than 175.4. Calculate the value of earthing resistance to be provided in order to ensure that only 10% of the alternator winding remains unprotected. Solution. Let r ohms be the earthing resistance required to leave 10% of the winding unprotected (portion NA). The whole arrangement is shown in the simplified diagram of Fig. 22.9. 3 ‘Voltage per phate, Vy oe =3810V all 7 = —10x108 V3 X 6-6 X10 Let the reactance per phase be x ohms. . to = LxHx8I5 s 100 or x = 04362 Reactance of 10% winding = 0-436 x 0-1 = 0.0436 2 EME. induced in 10% winding = Vj4,x 0-1 =3810x0-1=381V Impedance offered to fault by 10% winding is Z, = J{(0-0436) +77 Earth-fault current due to 10% winding 381_ 381 2, ffo-o1s6F a? ‘When this fault current becomes 175 A, the relay will trip. s 17s = —— 381 __ y(0-0436) +7? 381) or (0-0436 +9? = 2) or (0.04367 +7? = 4-715 or r=2a7Q‘Example 22.2. 4 star-connected, 3-phase, 10 MVA, 6-6 kV alternator is protected by Merz- Price cireulating-current principle using 1000/5 amperes current transformers. The star point of the alternator is earthed through a resistance of 7-5. If the minimum operating current for the relay is 05 A, calculate the percentage of each phase of the stator winding which is unprotected against earth faults when the machine is operating at normal voltage. Solution, Let x % of the winding be unprotected. Farthing resistance, Q 6-6 x 10°/¥3 = 3810 V operate the relay 1000 50.5 — 100.8 EME. induced in.x% winding = V,,, x (x/100) = 3810 x (2/100) = 38-1 x volts Earth fault current which x% winding will cause 38:1x _ 38:1x ‘Voltage per phase, Van r 75 eres ‘This current must be equal to 100 A. a: or Unprotected winding 100% 7-5 _ e994 Hence 19-69% of alternator winding is left unprotected. Example 22.3, A 10 MVA, 6-6 k¥; 3-phase siar-connected alternator is protected by Mer2-Price circulating current system. If the ratio of the current transformers is 1000/5, the minimum operating current for the relay is 0-75 4 and the neutral point earthing resistance is 6 Q, calculate : © the percentage of each of the siator windings which is unprotected against earth faults ‘when the machine is operating at normal voltage. () the minimum resistance to provide protection for 90% of the stator winding. Solution. Fig. 22.10 shows the circuit diagram. Current . Current transformers pare transtormers — 7 TOSS \ ~\ R C OOOO } — 7865} fos Y CSSTTS of B a + Main r=62 s/t Switch Pilot + wes( Letx% of the winding be unprotected. Barthingresistance, r= 6 Voliage perphase, Tig = 66% 108/3 = 3810 volts Minimnam fait curent which will operate the relay 1000 9.75 = 150 EMF. induced in x% of stator winding = Py X (8/100) ~ 3810 X (x/100) ~ 38-1 x volts Barth fault current which x% winding will cause B8-1x _ 38-1x + 2 amy ‘This must be equal to 150A. 38-1 ” 150 3 or x = 23-696 (i Let rohms be the minimum earthing resistance required to provide protection for 90% of stator winding. Then 10% winding would be unprotected i.e. x= 10%. 38-1x 38-Lx _ 38-110 150 150 Example 22.4, A star-connected, 3-phase, 10 MVA, 6-6 kV alternator is protected by circulat- ‘ing current protection, the star point bemg earthed via a resistance r. Estimate the value of earthing resistor if 85% of the stator winding is protected against earth faults. Assume an earth fault setting 0f 20%. Neglect the impedance of the alternator winding. Solution, Since 85% winding is to be protected, 15% would be unprotected. Let r ohms be the earthing resistance required to leave 15% of the winding unprotected. 6 Fullsload current = 1010" Lgrg 4 V3 X66 X10" ‘Minimum fault current which will operate the relay. 20% of full-load current 20 = 722x876 = ico 154 ‘Voltage induced in 15% of winding 15 66x10" o 130 2540 '30V3 volts - jo Earth fault current which 15% winding will cause — 330V3 r This current must be equal to 175 A. irs = 33048 r or 7 = B08 L270 175
You might also like
Generator Protection PDF
PDF
100% (1)
Generator Protection PDF
10 pages
Power Sys. Analysis PDF
PDF
No ratings yet
Power Sys. Analysis PDF
40 pages
Transient Response of A Separately Excited DC Motor Under No-Load Condition
PDF
100% (1)
Transient Response of A Separately Excited DC Motor Under No-Load Condition
6 pages
Lecture1 Singly Excited System
PDF
86% (7)
Lecture1 Singly Excited System
79 pages
DC Motor Drives
PDF
No ratings yet
DC Motor Drives
53 pages
Fundamentals of Power System Protection & Circuit Interrupting Devices
PDF
No ratings yet
Fundamentals of Power System Protection & Circuit Interrupting Devices
50 pages
Ipq&f U5
PDF
50% (2)
Ipq&f U5
6 pages
Zero Power Factor or Potier Triangle Method 7
PDF
100% (1)
Zero Power Factor or Potier Triangle Method 7
3 pages
11kVA 3 = 6350.85V 10 MVA 3 (11 kVA) = 525 A 525 (20 %) =105 A 105 A= 6350.85 V (X) 9 Ω
PDF
100% (1)
11kVA 3 = 6350.85V 10 MVA 3 (11 kVA) = 525 A 525 (20 %) =105 A 105 A= 6350.85 V (X) 9 Ω
3 pages
Electrical Machines-II Unit 1
PDF
No ratings yet
Electrical Machines-II Unit 1
35 pages
Electrical Engineering - Engineering - DC Machines and Synchronous Machines - Synchronous Machines - Notes
PDF
No ratings yet
Electrical Engineering - Engineering - DC Machines and Synchronous Machines - Synchronous Machines - Notes
73 pages
3 Point Starter
PDF
100% (1)
3 Point Starter
2 pages
Question Bank - Unit 5 (Circuit Breaker)
PDF
No ratings yet
Question Bank - Unit 5 (Circuit Breaker)
2 pages
Equivalent Circuit and Phasor Diagram of Synchronous Generator or
PDF
No ratings yet
Equivalent Circuit and Phasor Diagram of Synchronous Generator or
3 pages
L-13 (DK) (Pe) ( (Ee) Nptel)
PDF
No ratings yet
L-13 (DK) (Pe) ( (Ee) Nptel)
108 pages
Three Phase
PDF
100% (1)
Three Phase
78 pages
DC Motors Starters and Breaking Methods
PDF
No ratings yet
DC Motors Starters and Breaking Methods
25 pages
Lecture 8 DC Machines II
PDF
No ratings yet
Lecture 8 DC Machines II
15 pages
Questions & Answers On Synchronous Motors
PDF
100% (1)
Questions & Answers On Synchronous Motors
28 pages
13 - Bus Zone Protection
PDF
No ratings yet
13 - Bus Zone Protection
9 pages
Technical Notes - Fuse
PDF
No ratings yet
Technical Notes - Fuse
16 pages
Simplex Wave Winding
PDF
No ratings yet
Simplex Wave Winding
8 pages
Introduction To Power Quality & Facts - MCQ - Unit-3 - GoWithQuiz
PDF
No ratings yet
Introduction To Power Quality & Facts - MCQ - Unit-3 - GoWithQuiz
4 pages
PU System 2
PDF
No ratings yet
PU System 2
26 pages
Tutorial 1
PDF
100% (1)
Tutorial 1
8 pages
3 Phase Induction Motor Question Bank
PDF
No ratings yet
3 Phase Induction Motor Question Bank
2 pages
Voltage Regulation of Synchronous Generators
PDF
No ratings yet
Voltage Regulation of Synchronous Generators
8 pages
Unit-2 (DC Motors)
PDF
No ratings yet
Unit-2 (DC Motors)
50 pages
CH-1 - DC Generator Q.bank PDF
PDF
No ratings yet
CH-1 - DC Generator Q.bank PDF
2 pages
Electrical and Electronics
PDF
100% (1)
Electrical and Electronics
3 pages
ACTIVITY 1: Three Phase Alternator: Open-And Short-Circuit Characteristics
PDF
No ratings yet
ACTIVITY 1: Three Phase Alternator: Open-And Short-Circuit Characteristics
17 pages
Commutator in DC Motor
PDF
100% (1)
Commutator in DC Motor
2 pages
Applications-Light Dimmer, Excitation System and Solar PV System in Phase Controlled Converters
PDF
100% (1)
Applications-Light Dimmer, Excitation System and Solar PV System in Phase Controlled Converters
7 pages
Assignment # 01 17EL Sec-1, II, III
PDF
100% (1)
Assignment # 01 17EL Sec-1, II, III
2 pages
Radial Feeder Protection
PDF
100% (1)
Radial Feeder Protection
5 pages
Electric Drives
PDF
No ratings yet
Electric Drives
44 pages
Methods of Improving Transient Stability
PDF
No ratings yet
Methods of Improving Transient Stability
2 pages
Sanfoundry Induction Motors
PDF
No ratings yet
Sanfoundry Induction Motors
53 pages
AC Power Tut Qns PDF
PDF
No ratings yet
AC Power Tut Qns PDF
26 pages
Lecture 10 - Rev 02 - May 2019 - Generator Prot
PDF
No ratings yet
Lecture 10 - Rev 02 - May 2019 - Generator Prot
24 pages
VK Mehta - Altrernator Protection
PDF
No ratings yet
VK Mehta - Altrernator Protection
21 pages
Components of Power System
PDF
100% (2)
Components of Power System
12 pages
Starting of Three-Phase Induction Motor (1/Ch. 35)
PDF
No ratings yet
Starting of Three-Phase Induction Motor (1/Ch. 35)
10 pages
Module2 - Generation of High Voltage - Current - HVE
PDF
No ratings yet
Module2 - Generation of High Voltage - Current - HVE
44 pages
Lecture 10
PDF
No ratings yet
Lecture 10
24 pages
REF Protection
PDF
No ratings yet
REF Protection
4 pages
Final All Math
PDF
No ratings yet
Final All Math
8 pages
Two Marks - UNIT IV - 28.10.2022
PDF
No ratings yet
Two Marks - UNIT IV - 28.10.2022
13 pages
Additional Problems
PDF
No ratings yet
Additional Problems
2 pages
Questions & Answers On Efficiency and Voltage Regulation
PDF
No ratings yet
Questions & Answers On Efficiency and Voltage Regulation
18 pages
Synchronous Motor MCQ PDF (Erexams - Com)
PDF
No ratings yet
Synchronous Motor MCQ PDF (Erexams - Com)
6 pages
AE10 Sol
PDF
No ratings yet
AE10 Sol
223 pages
Worked Examples For A Three - Phase Induction Machine
PDF
No ratings yet
Worked Examples For A Three - Phase Induction Machine
12 pages
Revolving Field Theory
PDF
No ratings yet
Revolving Field Theory
1 page
B.sc. Generator Protection
PDF
No ratings yet
B.sc. Generator Protection
10 pages
Symmetrical Fault Analysis
PDF
No ratings yet
Symmetrical Fault Analysis
12 pages
Services Design Midsem - Docx Ab
PDF
No ratings yet
Services Design Midsem - Docx Ab
5 pages
07 Space Vector Modulation
PDF
No ratings yet
07 Space Vector Modulation
9 pages
Assignment Induction Motors
PDF
No ratings yet
Assignment Induction Motors
3 pages
Load Flow Matrices IIT Roorkee Notes NPTEL
PDF
100% (1)
Load Flow Matrices IIT Roorkee Notes NPTEL
88 pages