PROJECT: ISP-TUTIKORIN-HWB-TUAMAN
OBJECTIVE:
Hydraulic calculation of the pump 43 P017 A/B for ascertaining the Pump Rated KW for handling Service fluid of rated capacity 7 Cum / Hr.
with required Head
INPUTS
Fluid to be Pumped
N Butanol + S2 + HCL
(aq)
Fluid Density 970 kg/Cum
Fluid Viscosity 3.8 cP
Pumping Temperature 40 Deg. C
Design Temperature 60 Deg. C
Static suction head considered from pump centerline 785 mm
Minimum Liquid level 333 mm
Corrioils type flow meter pressure drop considered 0.1 kg./cm^2 As per ABB data
ASSUMPTIONS
Pump Efficiency 20%
Suction vessel pressure considered 1 kg/cm2 (g) as per vessel data sheet. The operating pressure of
the vessel is 0-1 kg/cm2 (g). The vacuum condition will happen during operation of vent and vacuum
system during which the pump will not be in operation.
Pipe roughness for MSGL Considered as As per Perry Handbook
0.0015 mm. Page No.5-24
Pipe Length for Hydraulic Calculation Considered 1.5 times from actual length in suction line
Pipe Length for Hydraulic Calculation Considered 1.5 times from actual length in Delivery line
For pump no. 43P17 A/B, Fluid is pumped to 43 V11. So 43 V11 is the only line which we have
considered for hydraulic calculation of pump.
L/D ratio for valves and fittings is taken reference from "CRANE BOOK"
Equiations Used in Calculation
Friction factor "f" has been calculated from Colebrook white equation (modified) equation (when
Reynold's number is > 2100) ,
f = 0.25 / [ log { €s / (IDs X 3.7) + 5.74/ Re0.9 } ] 2
Friction factor "f" has been calculated (when Reynold's number is < 2100) , f = 64 / Re
TDH = Total Differential Head = Total discharge head in meter - Total suction head in meter
NPSH Available in meter = Suction Head Sum in meter - Vapour pressure in meter (P vp)
The L/D Ratio for Reducer / Expander calculated based on Crane Handbook Page No.A-26
Refer Annexure - 1 for Pipe fittings, Valve and misc Items in Pipe Routine in relation with
Calculation of System resistance
Page 1 of 7
Annexure - 1
Suction 80-PDT-0566-GL-UI
Note:
1) Pipe lengths in Suction and Discharge are lengths Calculated from the Layout
Page 3 of 7
FTS CONSULTANTS PVT. LTD.
PROJECT: ISP-TUTIKORIN-HWB-TUAMAN
Calculation basis of pump 43P17 A/B
SL.NO. DESCRIPTION DETAILS SYMBOL UNIT DATA REMARKS
1 Pipe line details
2 MOC of pipe - MSGL
3 Suction Pipe length approx. Ls m 4.5 Note 1
4 Nominal Diameter (NB) NBs mm 80 As per P & I diagram
5 Outside diameter (OD) ODs mm 88.9 As per standard data
PROJECT: ISP-TUTIKORIN-HWB-TUAMAN
Friction factor, Reynold number and velocity calculation of pump 43P17 A/B REV-03
SL.NO. DESCRIPTION SYMBOL REFERENCE UNIT CALCULATION REMARKS
FLUID VELOCITY CALCULATION
SUCTION SIDE
2 Design Flow rate Qsd From process data sheet of HWB m3/hr. 7
6 Design Flow rate Qsd From process data sheet of HWB m3/hr. 7
7 Inside diameter (ID) IDs As per P & I diagram mm 45.22 As per standard data/Considered 2 mm
glass line thickness
8 Velocity of fluid Vs Velocity, V=Q/A where, Q= flow and A = area m/s 1.2
SUCTION SIDE
Res Re = Fluid Velocity x Fluid Density x Actual Res > 2300, so, flow is considered as
3 Reynolds No. Diameter / Fluid Viscosity 9080
turbulent
DELIVERY SIDE
Red Re = Fluid Velocity x Fluid Density x Actual Res > 2300, so, flow is considered as
6 Reynolds No. 13988
Diameter / Fluid Viscosity turbulent
SUCTION SIDE
2 from equation , f = 0.25 / [ log { €s / (IDs X 3.7) + 5.74/ Re } ] Colebrook white equation (modified)
0.9 2
DELIVERY SIDE
2 from equation , f = 0.25 / [ log { €s / (IDs X 3.7) + 5.74/ Re0.9 } ] 2 Colebrook white equation (modified)
SUCTION SIDE
DELIVERY SIDE
Transfer of N-
Butanol+S2+Hcl (aq.) from
1 Duty/ Case From process data sheet of HWB - Dump Tank (43V17) to
Product Tank (43V11)
16 Inside diameter (ID) IDd As per standard data mm 45.22 For discharge side/Considered 2 mm
glass line thickness
17 Loss of pressure due to Control valve bar 0
18 Loss of pressure due to Orifice meter mm 0
19 Loss of pressure due to flow meter(Corilos meter) kg/cm^2 0.1 From ABB data sheet
m 1 Eqivalent
EQUIVALENT LENGTH CALCULATION
SUCTION SIDE
Sl. No. TYPE L/D Dia ( m) No. Eqv. Length(m) Remarks
1 Ball Valve 3 0.070 0 0.00
2 90 deg Elbow 30 0.070 2 4.18
3 Tee ( Branch ) 60 0.070 1 4.18
4 Y Strainer 250 0.070 1 17.42
5 Reducer 30 0.070 1 2.09
6 Spectacle blind 0 0.070 1 0.00
7 Diaphragm valve 160 0.070 2 22.29
8 Total Suct. Val&Fit Eq. Lengths (m) 27.86
9 Length of Suct. straight pipe (m) 4.5
10 Total Equivalent Suct. length (m) 32.36
DELIVERY SIDE
Sl. No. TYPE L/D Dia ( m) No. Eqv. Length(m) Remarks
1 Ball Valve 3 0.045 0 0.00
2 90 deg Elbow 30 0.045 8 10.85
3 Tee ( Run ) 20 0.045 2 1.81
4 Check Valve 135 0.045 1 6.10
5 Reducer 20 0.045 1 0.90
6 Diaphragm valve 160 0.045 2 14.47
7 Total Disch. Val&Fit Eq. Lengths (m) 34.14
8 Length of Disch. straight pipe (m) 19.5
9 Total Equivalent Disch. length (m) 53.64
SUCTION & DISCHARGE HEADS AND PUMP POWER REQUIREMENT
SUCTION & DISCHARGE HEADS REFERENCE UNIT SUCTION DISCHARGE
Vessel Pressure m 10.862 10.862
Liq. Level m 0.150 0.000
Static Head m 0.765 5.000
Considering 30 % extra as safety
Total Fric. Head Loss m -0.26 3.3 factor
Velocity Head m -0.0133 0.07
Entry loss m -0.0066 0.0
Exit loss m 0.000 0.07
Total Head metres of Fluid (abs) 11.5 19.3
DIFFERENTIAL HEAD
Discharge Head Sum m 19.29
Suction Head Sum m -11.50
TDH=Total Differential Head m 7.78
SYSTEM POWER
Efficiency (note 4 ) = (<1) 20%
Estimated Power (BKW ) (KW) 0.72
Recommended Motor KW(considering 15% mergin)= (KW) 0.83
NPSH
Suction Head Sum m 11.50
Pvp m -0.54
NPSH Available m 10.96
RESULTS OR SUMMERY
Total Differential head (As per calculation) M 7.78
Motor KW ( As per calculation ) KW 0.83
NPSH available M 10.96
CONCLUSION / SUMMARY
RESULTS OF CALCULATION
Total Differential head (As per calculation) M 7.78
Motor KW ( As per calculation ) KW 0.83
NPSH available M 10.96
Recommendation / Conclusion
Pump Capacity calculated based on Size in Suction and Delivery as indicated in P&ID.