Mcomp
Mcomp
PROTECTION
RELAYS
for
Total Peace of Mind
Switchgear Factory, Navi Mumbai
L&T Switchgear, a part of the Electrical & The selection of Motor Protection System
Automation business, is India's largest should be based on the cost and
manufacturer of low voltage switchgear, with application of the electric motor. Its
the scale, sophistication and range to meet appropriate selection not only prevents
global benchmarks. With over five decades of motor damage, but also ensures optimal
Larsen & Toubro is a experience in this field, the Company today process efficiency with minimal
Switchgear Factory, Ahmednagar enjoys a leadership position interruption.
technology-driven company
in the Indian market with a growing
that infuses engineering with international presence. Pick the motor protection relay that
imagination. The Company meets your needs:
It offers a complete range of products
offers a wide range of
including powergear, controlgear, industrial
advanced solutions in the field automation, building electricals & automation,
of Engineering, Construction, reactive power management, energy meters,
Index Nos.
Appendix ii 13
Product selection Guide
1
MPR200nX /
New
MPR300 Technical specifications
R R
Y Y
B B 106
R Y B N
N N
Fuse In case of reversible starters; Fuse
Start Aux. N/O MPR200nX / MPR300 must be placed before
N/O the reversing contactors. 42.6 16 Ø12 - 3 Places
Stop
(N/C) MPR200nX / MPR3000 must sense Line Current
in case of star Delta Starter
85
35.5
B
1 2 3 4 5 6 7 8
70
Y
NC NO Aux
Forward Reverse
R
Supply
Contactor Contactor Line Delta Star
MPR200nX / MPR300 Contactor Contactor Contactor
3Ø Motor
3Ø Motor
2 3
MM10 Technical specifications
37, 46, 49, 50/ 51, 51LR, 64 Metering IR, IY, IB, IO, Thermal Capacity
• Thermal Overload With Digital Input + Output 1 DI + 2 CO Type DO
Warning
Monitoring Last 1 Trip
• Under Current
• Unbalance Auxiliary Supply 110 - 240 V AC/DC
• Phase Loss
Current Input 5 A CT secondary
• Phase Sequence Reversal
• Earth Fault Binary Input Voltage Rating 12 V supplied internally
• Prolong Starting, Locked Rotor Rating 5 A, 250 VAC (cosφ = 1)
• Short Circuit
Output Contact Operating time 15 ms Max
Electrical life 1,00,000 Operations at IR
Features Mechanical life 5 x 106 Operations
• 4 Digit LED display • Relay output ‘R1‘ works with fail-safe logic. Maximum Power Consumption 3 VA typical
• Measurement of RYB, Zero Sequence current and For technical info on fail-safe logic, refer Appendix I
Thermal capacity. • 1 no. Programmable Binary input for remote operation. Burden on CT 0.3 VA at Rated Current
• Separate LED's for indication of Motor operational, Trip & It can be configured for either of these operations:
I) Inhibit Motor Start Operating Temperature -5⁰C to +55⁰C
Thermal OL/ pre-alarm status.
ii) Trip Reset
• Programmable thermal OL time constant right from Degree of Protection IP52
iii) Instant Tripping
1 sec to 40 sec. • Relay testing facility
• 2 nos. of C/O output contacts. Weight 0.75 Kg
Test push button to check working of relay contacts.
The relay 2 output is programmable type. It can be • Trip data recording Mounting Panel Mounted
configured for following conditions: Fault current or cause of last trip is displayed.
I) On any tripping Dim W×H×D in mm 96 × 96 × 110
ii) On thermal tripping
iii) On thermal Warning Panel Cut Out in mm 90 × 90
L3 L2 L1 F4
F1 F2 F3
K1 MM10 110 mm
L
9 1 100 mm
96 mm 90 mm
Aux
N
10 2
11 3 NO
12 4 NC S2
R1 Stop
COM
96 mm
90 mm
13 5
Protection
Front Side
class CT’S COM
S1
Panel Cutout
14 6
Start K1
R2
15 7 NC
Binary
Input NO
16 8
K1
M H1
Bloack R1/
Reset/
Trip
N
External CT's - Protection class CT's [5 - 1000 Amps] with 5 Amp secondary
4 5
MM30 Technical specifications
• Auto setting of parameters. By feeding just few • 8 LED's for fault indication. Current Input 1/5 A CT Site selectable
parameters, other parameters can be automatically set. • Control on number of starts of motor Rating 5A
• Draw out enclosure • Starting sequence control
• 8 digit alpha numeric display During start-up of the motor, the unit can control an Output Contact Operating time 40 ms max
• Real Time Measurements output contact to automatically manage the starting Electrical life 1,00,000 operations at IR
• Measurement and display of actual and trip data transition. Maximum Power Consumption 8.5 VA typical
recordings. • RS485 port for communication on Modbus Protocol
Burden on CT 0.2 VA for 5A, 0.01 VA for 1 A
Operating temperature 10⁰C to 60⁰C
Wiring diagram Weight < 2 kg
Mounting Panel Mounted
Construction Draw out
Dim W × H × D in mm 121 × 158 × 224
A B A B C
Panel Cut Out in mm 113 × 142
C 21
R1 (21) (10)
25 25 Display 10
11 N.O. N.O.
26 26 Microp. 22
R2 7 Dimensions
27 27 MM30 9 N.C. N.C.
8
28 28 R3 18
Function 20
39 39
29 29 19
F37 R1 R4 4
41 41 F46 6
30 30 F49
R2 5
32 F51
32
F51R R5 15
43 43
31
In=5A
31 ˜˜˜ F64
St.No.>
AI.0>
R3
R4
17
16
Microelettrica
Milano
Scientifica
Italia
42 42
164
In=1A Itr 14 Mode Select +
33 33 Progr. 3
R5 -
Int. Fault 2 Prog.
44
1
C Enter / Reset
121 204
224
Panel Cut-out 113 x 142 (L x H)
6 7
MCOMP User Friendly Options & Features
Advanced Features
MCOMP is Intelligent Motor Control Centre (IMCC) Relay. It • Maximize your asset availability and reduce downtime
has been designed as a reliable building block for low • Enable an energy management strategy
voltage, contactor - controlled motor starter feeders in • Protect your personnel and assets
Re-acceleration
switchgear assemblies. Excessive start time protection
Further benefits are gained from wide communication
capabilities that include Modbus RTU, Profibus, Modbus RTD or PTC based temperature protection
With the ability to quickly gather, organize and analyze
TCP / IP. Communication failure protection
information from your operations, our smart MCOMP Relay
Fail to stop protection
allows you to:
Interlock as Stop/Alarm/Trip
voltage board and a communication board in a single additionally used to configure the installed MCOMP
module enclosure. The main unit is also equipped with relay. The OLED display unit is provided with mini-USB STP cable
Bi/Tri color LED for status indication. There is also a port on its front facia to enable local configuration
reset push button available for local trip reset. through laptop using the MCOMP suite
parameterization software supplied with the relay.
8 9
Protection Typical Wiring Diagram
MCOMP provides all basic current, voltage and frequency thermal capacity is below the requisite safe threshold level.
protection. It also provides motor-specific protection like All protections are defined to cover the widest conceivable R
Y
locked rotor, number of starts, excessive start time, phase range of applications. B
N
FUSE L/+
the right time. It continuously monitors motor thermal earth fault protection. Sensitive earth fault protection is
capacity and trips the motor in case the thermal capacity provided through an external CBCT. The table below shows N/-
gets consumed. It does not allow the motor to start unless the setting range of protection available in MCOMP. 1 2 3 4 71 72
N B Y R N/- L/+
2 4 6
3-PH.VOLTAGE AUX.VOLT
CONTACTOR
1 3 5 START1
61 DI1 82
62 DI2 83
DIGITAL INPUTS
PROTECTION FUNCTION ANSI CODE VARIABLE RANGE STOP
90
CBCT
Alarm 110% of pick up CM UNIT 91
PWR/COMM
MOTOR STATUS
TRIP
RST ENT L
N
S2
Over Current 50P Pick Up 50 – 1000% Iflc R Y B
RTD/PTC
53 56 51 54
ANALOG O/P RS485
D+ D-
FUSE
L/+
1 3 5
DIGITAL INPUTS
MOTOR STATUS
CBCT
ALARM/PICKUP
CM UNIT RTD/PTC ANALOG O/P RS485 L
RST ENT
TI1 TI2 AO1 AO2 D+ D- TRIP
S1
R Y B 4-20mA OUTPUT
Trip Delay 0.5 – 30 Sec TO FIELD AMMETER
10 11
Appendix i Appendix ii
The relay contact gets de-energized in the following cases: Category Sub-Category MPR200nX / MM10 MM30 MCOMP
1. Auxiliary supply failure MPR300
2. Trip issued by MPR as per protection settings
General Display × 4 Digit LED Alphanumeric 4 line OLED
Display Display Display
MPR with fail-safe logic:
Current Input CT Sec. Inbuilt CT 5A 1 / 5A site Its own CT
1. Will disable the starting of motor in case auxiliary supply is not applied to the MPR or there is an internal defect up to 88A selectable unit up to 80A
2. Will trip the motor in case of auxiliary supply failure to MPR or there is an internal defect in MPR Thermal O/L (49) ü ü ü ü
Earth Fault (51N / 64) ü (MPR300 only) ü ü ü
Application:
Recommended in process plants where Motor shut down is not desired in case of failure of auxiliary power supply.
12
Electrical Standard Products (ESP) Offices:
CBMC/PRD/072016
Tel: 044-2270 6800 Lucknow 226 016 Tel: 0265-6613610 / 1 / 2
Fax: 044-22706940 Tel: 0522-4929905 / 04 Fax: 0265-2336184
e-mail: [email protected] Fax: 0522-2311671 e-mail: [email protected]
e-mail: [email protected]
67, Appuswamy Road Door No. 49-38-14/3/2, 1st floor,
Post Bag 7156 No: 73, Karpaga Nagar, 8th Street NGGO's Colony, Akkayyapalem,
Opp. Nirmala College K. Pudur Visakhapatnam - 530 016
Coimbatore 641 045 Madurai 625 007 Tel: 0891-2791126 / 2711125
Tel: 0422-2588120 / 1 / 5 Tel: 0452-2567405 / 2561068 / 2561657 Fax: 0891-2791100 SP50576R1
Fax: 0422-2588148 Fax: 0452-2567552 e-mail: [email protected]
e-mail: [email protected] e-mail: [email protected]
Regd. Office: L&T House, N. M. Marg, Ballard Estate, Mumbai - 400 001, INDIA. CIN: L99999MH1946PLC004768