Parameter Menghitung Temperatur Kalorik (Caloric Temperatur, T

The document provides data for designing a shell and tube heat exchanger to heat kerosine from 75°F to 120°F and cool gasoline from 160°F to 120°F. The data includes inlet and outlet temperatures for both fluids, fouling factors, pressures, maximum pressure drops, and flow rate of kerosine. Caloric temperatures are calculated for both fluids using the given temperature ranges and fluid properties. An energy balance calculation is then outlined to aid in the heat exchanger design.

Uploaded by

Riski Maulana
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
371 views4 pages

Parameter Menghitung Temperatur Kalorik (Caloric Temperatur, T

The document provides data for designing a shell and tube heat exchanger to heat kerosine from 75°F to 120°F and cool gasoline from 160°F to 120°F. The data includes inlet and outlet temperatures for both fluids, fouling factors, pressures, maximum pressure drops, and flow rate of kerosine. Caloric temperatures are calculated for both fluids using the given temperature ranges and fluid properties. An energy balance calculation is then outlined to aid in the heat exchanger design.

Uploaded by

Riski Maulana
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 4

200 lb/jam akan dipanaskan kerosine dari temperature 75 F sampai 120 F dengan

mendinginkan aliran Gasoline dari temperature 160 menjadi 120 F. Fouling factor untuk aliran
oil refinery digunakan untuk masalah ini. data lain yang belum tersedia dapat dicari di
referensi. Rancanglah shell and tube HE untuk soal diatas
Data-data yang tersedia :

Fluida Panas Gasoline


Fluida Dingin Kerosine
T in fluida panas (T1) 160 F
T out fluida panas (T2) 120 F
T in Fluida dingin (t1) 75 F
T out fluida dingin (t2) 120 F
Fouling Factor Panas (Rdg) 0.0005
Fouling Factor dingin (Rdk) 0.001
P inlet (fluida panas) 50 psia
P outlet (fluida dingin) 50 psia
ΔP max (fluida panas) 7 psi
ΔP (fluida dingin) 10 psi
Laju alir kerosine 200000 lb/jam

Langkah 1
Menghitung Temperatur Kalorik ( Caloric temperatur, Tc )
Parameter
T1 160 F
T2 120 F
t1 75 F
t2 120 F
r 1.125

API fluida panas gasoline 76 Kc kern 827


gasoline
T1-T2 40 F Fc
API fluida dingin kerosine 42 Kc
kerosine
t1-t2 45 F Fc

Caloric Temperature Fluida Panas Caloric Temperature Fuilda Dingin

Thc F tcc F

Fluida Properties

Spesific Gravity
76 API gasoline SG 0.6850
42 API kerosine SG 0.8000
Density
76 API gasoline SG 0.6850 ρg 685 kg/m3
42 API kerosine SG 0.8000 ρk 800 kg/m3

Spesific Heat
76 API gasoline Cg 0.57 Btu/lb.f
42 API kerosine Ck 0.48 Btu/lb.f

Viscosity
76 API gasoline μg 0.2 cp 0.483818 lb/f hr
42 API kerosine μk 1.6 cp 3.870544 lb/f hr

Thermal Conductivity
76 API gasoline kg 0.075 BTU/jam.f.F
42 API kerosine kk 0.083 BTU/jam.f.F

Langkah 2
Neraca Energi (Energy balance)

You might also like