1. System
2. System wiring
1. System
• ELD(Emergency Landing Device) is the device using battery power source to rescue the passenger to nearest floor safety when
power failure occurs.
Component
-1-
ELD Manual
1. System
ELD Diagram
-2-
ELD Manual
1. System
ELD occurs procedure
ELDI signal
Supply power
Building power off <Control panel> <ELD panel> Match car & hatch sill level Rescue people
After 5 seconds
ELDO signal
Turn off ELD power
-3-
ELD Manual
2. System Wiring
Building
ELD C/P
power
ER ES ET E EU EV EW R S T
TBEL-1
EOF1 P24
EOR N24
EOR1 ELDI
-4-
ELD Manual
-5-
ELD Manual
No
No
No Yes
Select the
Up direction
-6-
ELD Manual
HHT (HD-ELD)
1 0 0 0 0 1 1 1 0 0 0 0
nAC24V ELD_END SPI1 SPI2 SPI3 BTS2 BTS1 BTS0 RND POWER380B INV_BAT FLT
-7-
ELD Manual
HHT (HD-ELD)
WB_ELD100 Ver 1.08 ENT WB_ELD100 Ver 1.08 ENT WB_ELD100 Ver 1.08 ENT Battery Charging
Battery Ready !! BAT VOLT : 55.4[V] BAT VOLT : 55.4[V] BAT VOLT : 55.3[V]
BAT VOLT : 55.4[V] [1] DATA SETTING [1] DRIVE DATA BC VOLT : 24.6[V]
I/O : 10000/1110000! [2] INFORMATION [2] FAULT HISTORY BC CURR : 0.4[A]
-8-
ELD Manual
HHT (HD-ELD)
WB_ELD100 Ver 1.08 ENT WB_ELD100 Ver 1.08 ENT Battery Discharging !! ENT Battery Discharging !!
BAT VOLT : 55.4[V] BAT VOLT : 55.4[V] BAT VOLT : 55.3[V] BAT VOLT : 55.3[V]
[1] DATA SETTING [1] CHARGER DATA [1] OUT VOLT.SET [4] RUN MODE SEL
[2] INFORMATION [2] INVERTER DATA 53.0[V] 2.0
-9-
ELD Manual
1. ELD operating
Every 1 second
Display part Uu–216 U n – 12.6
- status
Battery Voltage 216 [V] Battery Current 12.6 [A]
- trouble
U u - : ELD operation [voltage]
U n - : ELD operation [current]
2. Battery charging
-10-
ELD Manual
Error code Problem Meaning Check point Error code Problem Meaning Check point
J5 connector(ARDP), M1 contactor,
E - 07 M2 Contactor E - 20 Input over voltage
ARDP board
Input voltage
> Over 15%, under 15%
E - 10 Fuse bowed off ARDQ board, load check E - 21 Input under voltage
-11-
ELD Manual
D1 D2 D3 D4 D5 D6
-12-
ELD Manual
D1 D2 D3 D4 D5 D6
D5 GREEN
on on ELD power output
If does not
If normal, flickers, the
D6 YELLOW Keep on for 5 sec after
flickers board is on on on ELD power off
ELD operation is finished
abnormal
-13-
ELD Manual
D1 D2 D3 D4 D5 D6
-14-
ELD Manual
1) [1] DATA SETTING > [4] FACTORY > [6] INV OC LEVEL : 280[V]
1) Keep On the ELD – ELD INV OC FLT
MC2 OFF 2) Check the BAT Volt, ELD wiring
2) Can not be On the ELD – ELD MODE SETTING
[1] DATA SETTING > [4] FACTORY > [14] VREF DELTA : 20
LED 6 not operated IC Fault problem Check the F3 fuse, change the board
Battery overvolatage Malfunction of Power board or CPU board Exchange Power Board or CPU Board.
Power board or Charger line connection is not Check 48V terminal connection, F1 fuse on Power Board, connection of Connector J1
Battery undervoltage
good. and J10, Batteries or Power Board.
-15-
ELD Manual
When building power is turn on, Battery switch is Due to over current, voltage, it affects
turned off with A Spark occurs. component defects.
-16-
ELD Manual
Cambodia 2 1 2 1 6
Iraq 7 3 10
Building power problem.
Vietnam 7 5 12
Bad material management status.
Myanmar 1 1 2
Confuse the Manual contents.
Total 19 1 7 1 3 1 32