35m Tower Check
35m Tower Check
35m Tower Check
Lx = 4.15 m
h mm 150 Density kN/m³ 24 1
Top cover mm 25 (Normal weight concrete) Plan
Btm cover mm 25
Edge 4
Edge 2
LOADING characteristic EDGE CONDITIONS
Self weight kN/m² 3.60 Edge 1 C C = Continuous
Extra dead kN/m² 2.72 Edge 2 C D = Discontinuous Ly = 6.35 m
Total Dead, gk kN/m² 6.32 gf= 1.40 Edge 3 D
Imposed, qk kN/m² 2.00 gf= 1.60 Edge 4 C 2
Design load, n kN/m² 12.05 See Figure 3.8 and clauses 3.5.3.5-6 Edge 3
SUPPORT REACTIONS (kN/m char uno) (See Figure 3.10) Sum ßvx = 0.863 Table 3.15
EDGE 1 EDGE 2 EDGE 3 EDGE 4 Sum ßvy = 0.720
1, F-G G, 2-1 2, F-G F, 2-1 equations
ßv 0.518 0.360 0.345 0.360 19 & 20
Dead kN/m 13.58 9.44 9.05 9.44
Imposed kN/m 4.30 2.99 2.86 2.99
Vs kN/m 25.9 18.0 17.3 18.0
OUTPUT/SUMMARY
SHORT LONG EDGE 1 EDGE 2 EDGE 3 EDGE 4
PROVIDE SPAN SPAN 1, F-G G, 2-1 2, F-G F, 2-1
MAIN STEEL T12 @ 475 B1 T12 @ 875 B2 T12 @ 350 T1 T12 @ 575 T2 T12 @ 575 T1 T12 @ 575 T2
REFERENCECALCULATIONS OUTPUT
2.0 Design of Roof Beam
Struct/ICE
R.C
manual,198
5 2.1 Preliminary member sizing:
Table 4 Span/effective depth ratio for initial design of continous beams =
=
Span of Longest beam =Bxx
Min. effective depth = Span/15=
Assume dia. of main bars =
Cover to main reinforcement =
Overall beam depth (h) = d+c+Dia./2
=
say
Table 2 Miminum beam width =
Imposed Load =
Critical Load combination Assume: 1.4DL + 1.6IL
Design Load (Qd)=
REFERENCE
2.4 Design of Hogging Moment Steel:
Effective depth, d = 450 - 25 - 16/2 =
fy = 410 MPa
f cu = 25 MPa
(3.4.4.4) K' = 0.156
Mu = 24.18 kNm
K= 0.022
Lever arm, z= 0.95d=
Area of steel, As
As= Mu /0.95fyz =
Table 3.25 As,min= 0.24% bh
Provide 2Y16 TOP an
REFERENCECALCULATIONS OUTPUT
3.0 Design of First Floor Slab
Struct/ICE
R.C
manual,19 NOTE: Slab Panel A is assumed to be crically loaded:
5
3.1 Preliminary member sizing:
Table 4 Span/effective depth ratio for initial design of continous slabs =
= 40
Longer span (ly ) = 5.65
Shorter span (lx ) = 3.23
Min. effec 80.8
Assume dia. of main bars = 12
Cover to main reinforcement = 25
Overall beam depth (h) = d+c+Dia./2
= 111.75
say 150
3.2 Load anaysis:
Conc. Unit weight = 24
Dead Load:
Self weight 3.6
Double coat plaster and tiling 0.22
Partitions (position unknown) 2.5
Total characteristic dead load 6.32
Imposed Load = 2.50
Ly = 5.65 m
Edge 3
REFERENCE
EDGE CONDITIONS
Edge 1 C
Edge 2 C
Edge 3 C
Edge 4 D
Slab classific (ly /lx )
REFERENCE CALCULATIONS
3.5 Shear Control:
Shear forces and shear resistance:
At position 2
Vsx = 20.75 kN
bv = 1000 mm
v= V/bv d 0.17
Table 7 & v c =
At positions 1,3
Vsx = 14.94 kNm
bv = 1000 mm
v= V/bv d 0.17
vc =
3.5 Deflection Control:
(Eqtn 8) fs = 2/3 x 410 x 192 /402 = 130.6N/mm²
(Table 3.10) Modification factor = 0.55 + (477 - 130.6) /120 /(0.9 +
(3.4.6.3) Permissible L/d = 26.0 x 2.000 = 52
(3.4.6.1) Actual L/d = 3230/107=30.187………. O.k
3.6 Crack Control:
cl. 3.12.11 Spacing of bars (Sv ) < 3d or 750mm whichever is less
3d = 3x107 = 321mm
REFERENCE CALCULATIONS
4.0 Design of First Floor Beams
4.1 CRITICALLY LOADED EDGE BEAM (B1)
4.1.1 Load anaysis:
Consider beam B1 at First Floor l
Conc. Unit weight =
Dead Load:
Self weight
Self weight of walls
Loads from slabs:
For Spans A-B, B-C, C-D, D-E, E-F:
Adopt Lx = 3.23 m Ly =
α = Ly/Lx 1.69
Slab dead loa6.32 kN/m2
but q = 0.5 n lx
qz = 0.625qlx
Total characteristic dead load =
Total characteristic live load =
Critical Load combination
Design Load (Qd)=
For span F-G:
Adopt Lx = 2.73 m Ly =
α = Ly/Lx 1.80
qz = q[1-1/(2α2) + 1/(8α3)]
Self weight
Self weight of walls
Total characteristic dead load =
Total characteristic live load =
Critical Load combination
Design Load (Qd)=
REFERENCE CALCULATIONS
4.1.2 Analysis of FRAME - 01:
From analysis:
Max.Sagging=
Max.Hogging=
Max.Shear Fo=
4.1.3 Design of Sagging Moment Steel:
Effective depth, d = 450 - 25 - 16
The beam is designed as a L-Beam:
fy = 410 MPa
f cu = 25 MPa
(3.4.4.4) K' = 0.156
Mu = 54.43 kNm
Cl. 3.4.1.5 where l
b eff = b w z
= 250 + 3440/10= 594mm
Check position of N.A
MRc = 0.447fcu hf bf (d-hf /2)
= 0.447x25x150x5
Since MRProvide
2Y16 Top and
K= 0.021 <
REFERENCE
4.1.4 Shear Control:
Shear forces and shear resistance:
Vsx = 102.00 kN
bv = 250 mm
v= V/bv d
Table 7 & 8 vc =
Since (vc+ 0.4) < v < 0.8 fcu or 5 N/mm2
Asv bv Sv (v - 0.4)/0.95fyv
Using 12mm dia. Stirrups,
Sv = 370.17 mm
PROVIDE Rc/
4.1.5 Deflection Control:
(Eqtn 8) fs = 2/3 x 410 x 288/402 = 196N/mm²
(Table 3.10)
cl.3.4.6.3 Permissible L/d = 20.8x 2= 41.6
cl. 3.4.6.1 Actual L/d = 4920 /417.0 = 11.799 ok
4.1.6 Crack Control:
cl. 3.12.11 Spacing of bars (Sv ) < 3d or 750mm whichever is less
3d = 3x417= 1251mm
Sv = 200mm < 750mm …………………………
4.2.1 Design of Hogging Moment Steel:
Effective depth, d = 450 - 25 - 16/2 =
The beam is designed as a L-Beam:
= 410 MPa
fy
f cu = 25 MPa
cl. 3.4.4.4 K' = 0.156
Mu = 79.62 kNm
REFERENCE CALCULATIONS
K= 0.073 <
REFERENCE CALCULATIONS
4.2 CRITICALLY LOADED INTERIOR BEAM (B2)
4.2.1 Load anaysis:
Consider beam B2 at First Floor l
Conc. Unit we=
Loads from slabs:
Trapezoidal loadings in all spans
Adopt Lx = 3.23 m
α = Ly/Lx 1.75
qz = q[1-1/(2α2) + 1
Total characteristic D
Self weight
Self weight of walls
Total characteristic live lo
Critical Load combination
Design Load (Qd)=
4.2.2 Analysis of FRAME - 02:
From analysis:
Max.Sagging=
Max.Hogging=
Max.Shear Fo=
4.1.3 Design of Sagging Moment Steel:
Effective depth, d = 450 - 25 - 16/2 =
The beam is designed as a T-Beam:
fy = 410 MPa
f cu = 25 MPa
Cl.3.4.4.4 K' = 0.156
Mu = 97.28 kNm
REFERENCE CALCULATIONS
Cl. 3.4.1.5 b eff = b w +l z /5;
= 250 + 3955/5= 1041mm
Check position of N.A
MRc = 0.447fcu hf bf (d-hf /2)
= 0.447x25x150x1041(4
Since MRc(340kNm > Mu(97.28kNm); N.A li
K= 0.021 <
z = 0.95d = 0.95x417 =
Area of steel, As
As= Mu /0.95fyz =
As,min= 0.24% bh
bv = 250 mm
v= V/bv d 1.77
Table 7 & 8 vc =
Since (vc+ 0.4) < v < 0.8 fcu or 5 N/mm2
Asv bv Sv (v - 0.4)/0.95fyv
Using 12mm dia. Stirrups,
Sv = 156.72 mm
REFERENCE
4.1.5 Deflection Control:
(Eqtn 8) fs = 2/3 x 410 x 631/804 = 215N/mm²
M/bd2 = 2.24
(Table 3.10)
(3.4.6.3) Permissible L/d = 20.8x 1.278= 25.903
(3.4.6.1) Actual L/d = 5650/417.0 = 13.549 ok
4.1.6 Crack Control:
cl. 3.12.11 Spacing of bars (Sv ) < 3d or 750mm whichever is less
3d = 3x417= 1251mm
Sv = 150mm < 750mm …………………………
4.2.1 Design of Hogging Moment Steel:
Effective depth, d = 450 - 25 - 16/2 =
The beam is designed as a L-Beam:
fy = 410 MPa
f cu = 25 MPa
cl. 3.4.4.4 K' = 0.156
Mu = 188.57 kNm
K= 0.174
As,min=
REFERENCE CALCULATIONS
4.2.2 Shear Control:
PROVIDE Rc/
4.1.5 Deflection Control:
(Eqtn 8) fs = 2/3 x 410 x 1474/1885 = 213.7N/mm²
M/bd2 = 4.34
(Table 3.10) Modification factor = 0.55 + (477 - 213.7)/120 /(0.9 +4.34) = 0.969
(3.4.6.3) Permissible L/d = 20.8x 0.969= 20.15
(3.4.6.1) Actual L/d = 5650/417.0 = 13.549 ok
4.1.6 Crack Control:
cl. 3.12.11 Spacing of bars (Sv ) < 3d or 750mm whichever is less
3d = 3x417= 1251mm
0.113 m2
24 kN/m3
2.7 kN/m
kN/m2
kN/m
1.42 kN/m Design Load (Qd)
in kN/m=
4.12 kN/m
9.17
2.12 kN/m
ume: 1.4DL + 1.6IL
9.17 kN/m
CALCULATIONS OUTPUT
Hogging Moment Steel:
= 450 - 25 - 16/2 = 417 mm
148.85851 mm2
270 mm2
vide 2Y16 TOP an (As = 402mm2 ) Provide
2Y16 Top and
Bottom
ar Force = V = 26.03 kN (As = 402mm2)
d= 417 mm
0.25 MPa < 0.8 fcu = 4.0MPa O.k
8 /402 = 101N/mm²
mp mod factor = 1 + 0.386 /(3 + 0.386) = 1.114 < 1.5
Modification factor = 0.55 + (477 - 101) /120 /(0.9 + 0.556) = 2.702>2
missible L/d = 26.0 x 1.114 x 2.000 = 57.924
0 /417.0 = 11.799 ok
m
m
mm
mm
th (h) = d+c+Dia./2
mm Adopt overall depth(mm) =
mm 150
kN/m3
kN/m2
kN/m2
kN/m2
kN/m2
kN/m2
Design Load (Qd)
in kN/m=
kN/m 12.85
CALCULATIONS
C = Continuous
D = Discontinuous
-8.44 kNm
6.30 kNm
-4.96 kNm
3.75 kNm
8.44
6.30
Moment Steel:
150 - 25 - 12/2 = 119 mm
1000 mm
< 0.156
OUTPUT
shear resistance:
d = 119 mm
MPa < 0.8 fcu = 4.0MPa O.k
0.645 Mpa > v, No shear reinforcement is required
d = 107 mm
MPa < 0.8 fcu = 4.0MPa O.k
0.693 Mpa > v, No shear reinforcement is required
2 /402 = 130.6N/mm²
ification factor = 0.55 + (477 - 130.6) /120 /(0.9 + 0.556) = 2.53>2
26.0 x 2.000 = 52
0/107=30.187………. O.k
OUTPUT
Design of First Floor Beams
CRITICALLY LOADED EDGE BEAM (B1)
A= 0.08 m2
24 kN/m3
1.80 kN/m
14.95 kN/m
B-C, C-D, D-E, E-F:
5.46 m
6.38 kN/m
ristic dead load = 23.13 kN/m
ristic live load = 2.52 kN/m
Assume: 1.4DL + 1.6IL
36.42 kN/m
4.92 m
but q = 0.5 n lx
7.48 kN/m
1.80 kN/m
14.95 kN/m
ristic dead load =24.23 kN/m
ristic live load = 2.96 kN/m
Assume: 1.4DL + 1.6IL
38.66 kN/m
OUTPUT
of FRAME - 01:
54.43 kNm
79.62 kNm
102 kN
f Sagging Moment Steel:
417 mm
ned as a L-Beam:
= 0.7x4.92 =3.44m
/10= 594mm
u hf bf (d-hf /2)
340kNm
0.156 Singly R.CBottom in
all spans
335.11573 mm2
270 mm2
= 402mm2 )
CALCULATIONS OUTPUT
shear resistance:
d= 417 mm
0.98 MPa < 0.8 fcu = 4.0MPa O.k
0.454 Mpa < v, Shear reinforcement is required
v < 0.8 fcu or 5 N/mm2
Provide Links
R12-200c/c
throughout beam
c THROUGHOUT THE BEAM SPAN span
8/402 = 196N/mm²
Modification factor = 0.55 + (477 - 196) /120 /(0.9 +0.527) = 2.191> 2
0 /417.0 = 11.799 ok
= 603mm2)
= 402mm2)
6/603 = 238.43N/mm²
.9 +1.832) = 1.278
OUTPUT
CRITICALLY LOADED INTERIOR BEAM (B2)
A= 0.08 m2
24 kN/m3
but q = 2x0.5 n lx
17.56 kN/m
al characteristic D 17.56 kN/m
1.80 kN/m
14.95 kN/m
34.31 kN/m
l characteristic live lo 6.87 kN/m
Assume: 1.4DL + 1.6IL
59.02 kN/m
of FRAME - 02:
97.28 kNm
188.57 kNm
184.6 kN
f Sagging Moment Steel:
= 450 - 25 - 16/2 = 417 mm
ned as a T-Beam:
OUTPUT
where lz = 0.7x5.65 =3.955m
/5= 1041mm
u hf bf (d-hf /2)
47x25x150x1041(4 395kNm
ce MRc(340kNm > Mu(97.28kNm); N.A lies within the flange and the beam
0.156 Singly R.C. Section
= 396.15 mm
shear resistance:
Provide Links
R12-150c/c
throughout beam
d= 417 mm span
MPa < 0.8 fcu = 4.0MPa O.k
0.454 Mpa < v, Shear reinforcement is required
v < 0.8 fcu or 5 N/mm2
CALCULATIONS
5 Deflection Control:
3 x 410 x 631/804 = 215N/mm²
> 0.156
Doubly R.C. Section
=K'fcu bd2 /[0.95fy (0.775d)]
s = As1 + As2
= 1,474.11 mm2
OUTPUT
c STIRRUPS
74/1885 = 213.7N/mm²
kNm
kNm
OUTPUT
mm
and
2Y16-BOTTOM
(As = 402mm2)
STRUCTURAL DESIGN OF REINFORCED CONCRETE MEMBERS
REFERENCE CALCULATIONS OUTPUT
1.0 Basic Design Data
1.1 Loads:
BS 6399-1:1996
(Table 1) Code of practice for dead and imposed loads typical floor 2.0 kN/m2
BS 6399-3:
1988 roof with no acess 0.6 kN/m2
-Floor finish + partition walls 2.5 kN/m2
-Density of building blocks 20 kN/m3
-Double coat plaster 0.22 kN/m2
-Partition walls (150mm thick) 2.5 kN/m2
-Site Location Lushoto, Tanga
150 mm 150 mm
2.2 Load anaysis:
Conc. Unit weight 24 kN/m3
Dead Load:
Self weight 3.6 kN/m2
Double coat plaster and tiling 0.22 kN/m2
Partitions (position unknown) 2.5 kN/m2
Total characteristic dead load (DL) 6.32 kN/m2
Imposed Load (IL)= 2.0 kN/m2
EDGE 2
EDGE 4
EDGE 3
EDGE 3
βvx,cont 0.51
βvx,discont 0.34
βvy,cont 0.36
βvy,discont -
fy = 460 Mpa
REFERENCE CALCULATIONS OUTPUT
fcu = 25 Mpa
K' = 0.156
Mu = 15.15 kNm
Table 3.25 For Rectangular section, Minimum Area of steel, As, min =
Deflection Control
= 1.69
(3.4.6.3) Permissible L/d = 26.0 x 1.69 = 43.94
(3.4.6.1) Actual L/d = 4150/119 = 34.97 < 43.94 ………. O.k
REFERENCE CALCULATIONS OUTPUT
2.4.2 Design of Main Re-bar for SaggingMoment Steel
Effective depth, d = h - c- Diam. Main bar/2
dx = 119 mm
Design slab width (b) = 1000 mm
fy = 460 Mpa
fcu = 25 Mpa
K' = 0.156
Mu = 11.41 kNm
Singly R.C.
K= 0.0322 < 0.156 Section
Lever Arm, z =
Since K (0.04279) < 0.043 then z = 0.95d = 113 mm 113 mm
Provide Y12-
= 1.69 250mm c/c -B1
(As = 452mm2/m)
(3.4.6.3) Permissible L/d = 26.0 x 1.69 = 43.94
(3.4.6.1) Actual L/d = 4150/119 = 34.97 < 43.94 ……..O.k
At positions 2,4
Vsx = 0.51(12.05kN/m2)(4.15m) = 25.5 kN
Adopt Critical Shear Force 25.5 kN
bv = 1000 mm
v = V/bv d 0.21 Mpa
v (0.21Mpa) < 0.8 √fcu = 4.0MPa ……………………. O.k
vc = 0.78 Mpa > v, No shear reinforcement is required
Crack Control:
Spacing of bars < 3d or 750mm whichever is less
3d = 3x119 = 357mm > 200mm ………………………….. O.k
fy = 460 Mpa
fcu = 25 Mpa
K' = 0.156
Mu = 5.81 kNm
fy = 460 Mpa
fcu = 25 Mpa
K' = 0.156
Mu = 7.68 kNm
5.97 kN/m
1.89
● bw + 0.2lz or
● The actual flange width or whicever is less
lz = the diatance between points of zero moments along the span of the
beam
From which lz = 5579 mm
bw = 250 mm
Now bf = b = 1365.8 mm
b=
say 1365 mm 1365 mm
Assume:
Diameter of main bars = 16 mm
Cover to main re-bar = 25 mm
Characteristic stregth of main re-bar 460 N/mm2
REFERENCE CALCULATIONS OUTPUT
Characteristic stregth of concrete 25 N/mm 2
= 787.776 kNm Mf =
787.776 kNm
Since M(114.55kNm) < Mf(787.78kNm) then, N.A lies within the
flange and the beam is designed as Singly Reinforced Section
= 0.019
Shear Control:
Shear forces and shear resistance:
V = 157.6 kN
bv = 250 mm
Clause3.4.5.3 v = V/bv d 1.51 Mpa
v (1.51Mpa) < 0.8 √fcu = 4.0MPa ……………………. O.k
thus , provide minimum links for the whole length of the beam such that;
Therefore, Sv = 373 mm
say 300 mm
Assume:
Diameter of main bars = 16 mm
Cover to main re-bar = 25 mm
Characteristic stregth of main re-bar 460 N/mm2
Characteristic stregth of concrete 25 N/mm2
= 0.133
= 342 mm
Provide
4Y16 + 2Y12-T
Table 3.25 For Rectangular Section, Minimum Area of steel, As, min = at All Supprots
And for secondary re-bar provide 3Y12-B from above(when determining Provide
secondary bars at span)
3Y12-B at All
supports
REFERENCE CALCULATIONS OUTPUT
4.0 DESIGN OF COLUMNS
Assume Column C1 to be Critically Loaded Column at Level 1
Dead Load:
Weight of roofing sheeting = (0.15xA) 1.812 kN
Weight of trusses = 1.5 x (1.8+2.035+2.075+1.075) 10.478 kN
Weight of roof beam = (1.8+2.035+2.075+1.075) x b x
h x γc) 18.860 kN
Upper Column self weight (A x lo x γc) 4.500 kN
Total 35.649 kN
Imposed Load:
Imposed Roof Load 7.24815 kN
Dead Load:
Load from Upper Column 35.649 kN
Load from First Floor Slab 43.489 kN
Imposed Load:
Imposed Roof Load 7.24815 kN
Imposed Floor Load 24.1605 kN
Total 31.4087 kN
From Analysis
lex/h 10.2
lex/h = 10.2
lex/b 11.22
ley/b = 11.22
Since both lex/h and ley/b < 15 ………. Short Column … Short column
d/h 0.728
take d/h = 0.75
0.061
0.3
From which,
250 mm2
s = 12 x 16mm = 192mm
y= 1.20 m
A= 0.97907 m2
Now B = 0.98948 m
Say B = L = 1.50m 2100 mm
Recall that;
Ultimate Moment, M = 59 kNm
Ultimate Load, Nd = 394 kN
Now;
Ϭ1 = 127.567 kN/m2
Ϭ2 = 51.12 kN/m2
From Figure 5.2 (a & b) attached hereunder;
= 0.8
= 62.6438 kNm
= 0.007
= 0.448 N/mm2
1577.3 mm
1577.3 mm
6309.2 mm
206.475 kN
0.09113 N/mm2
Shear check is
o.k
Shear check is
Number of bars o.k
17 pcs Provide
13Y16
(Asc= 1608mm2/m)
Bothways
PROPOSED TECHNICAL DRAWING TRAINING BUDGET
S/NO Item Description Unit Quantity Rate (TZS)
1.0 Tuition Fee payable to Facilitators hour 20 20,000.00
TOTAL
NING BUDGET
Amount (TZS)
400,000.00
60,000.00
750,000.00
300,000.00
1,510,000.00
SUBSTITUTE FRAME ANALYSIS
Moment of Member Joint
Joint Member Length, l(m) b, (m) h, (m) Inertia, Distr. Factor Check Sum D.F
Stiffness Stiffness
I(m 4)
CHECK:
Sum of Vertical Reactions = A 570.503
Total Load the System = B 570.503
Difference (A-B) 0.000 O.K
DESIGN OF PAD FOOTING FOR A 35M SQUARE TOWER SYSTEM
Input Data
Loads (kN)-Factored Mz
Fx Fy (kN.m)
Dead 23 394 0
Live 0 0 0
Wind 0 0 0
E 0 0 0
Sum 23 394 0
Foundation Level
H (mm) 2750 h (mm) 150
hw (mm) 2750 L/B 1
Pedestal Dimension
x (mm) 500 y (mm) 500
Concrete Strength
f'c (N/mm2) = 30
Steel Strength
fy (N/mm2) = 500
Allowable Soil Pressure
qa (kN/m2) = 150
Base Soil angle of internal friction 30
Approximate Footing Effective Depth d Assuming Punching Shear Governs (ACI 11.12)
*qumax (kN/m2) 132.40
d (mm) 280
280
* Fuy Muz Fux (H h) d (mm)= min 150mm (ACI 15.7.)
qumax= 6 User Input Depth
LB L2B
350
D (mm)= min cover 70mm (ACI 7.7.)
Foundation Weight Df (kN)
Concrete Slab = B * L * D * 25 38.5858
Pedestal = x * y * (H+h - D) * 25 15.31
Soil above Slab = (B*L - x*y) * (H - hw) * 19
Saturated Soil = (B*L - x*y) * (hw - D) * (19-10) 89.856
Total Df (kN) = 143.7543
d d
d/2 d/2
q6 q5
qumin q4 q3 q2 q1
qumax
CHECKING:
Contact Pressure
Fv (kN) = Fy + Df 537.754 qmax (kN/m2) 131.063 qmin (kN/m2) 48.130
Vc (kN) = 6,441
Vu (kN)* = 140.113
Vu / 0.85Vc 0.0256
*Vu = 0.5 * (q1+qumax) * (L/2 - x/2 - d) * B
max Vu / 0.85Vc = 0.0256 < 1.00 YES
Vu (kN)* = 337.801
Vu / 0.85Vc 0.2492
*Vu (kN) = Fuy - (0.5 * (q2+q5)) * (x+d) * (y+d)
max Vu / 0.85Vc = 0.2492 < 1.00 YES
Reinforcement: 0 .59 f y As
Mu = 0.9 f y As ( d )
f 'c B
x - Direction z - Direction
Bottom Reinforcement Top Reinforcement Top Reinforcement Bottom Reinforcement
Mu (kN.m)* 80.986 80.986 80.23 80.23
As (cm2)= 658 658 658 658
r= 0.00235 0.00235 0.00235 0.00235
min r = 0.0018 0.0018 0.0018 0.0018
r min = 0.0018 (ACI 7.12.) r max = 0.75 (0.85 f'c / fy) (600 / 600+fy) =
* x - direction moments:
Mu (Bottom R) = q3 * B * 0.5*(L/2-x/2)^2 + 0.5*(qumax-q3) * B * (2/3)*(L/2-x/2)^2
Mu (Top R) = qumin * B * 0.5 * (L/2-x/2)^2 (approximation)
* z - direction moment:
Mu (Bottom R) = 0.5*(qumax+qumin) * L * 0.5*(B/2-y/2)^2