MATSUSHITA Compressor Single Phase 115 V

MODEL# QA91K22CAU6 (80µF Start Cap.) R-134a 60 Hz

Voltage Range . . . . . . . . . 103 Volts to 127 Volts @ 60 Hz Refrigerant Control . . Capillary Tube
Application . . . . . . . . . . . . High Back Pressure Evaporator
Compressor Cooling . . . . Fan Cooling Temp. Range . . . . . . . 23°F to 59°F / -5°C to 15°C

Rated Performance Data Performance Curves


Capacity . . . . . . . . . . . . . . 3,175 Btu/h ±10% *
E.E.R. . . . . . . . . . . . . . . . . . 7.40 Btu/Wh ±10% * 550

Input Power (W)


Current . . . . . . . . . . . . . . . 4.85 Amps * 500
450

Nominal Motor Data Motor Input . . . . 429 Watts* 400

Rated Current . . 3.99 Amps 350

Type . . . . . . . . . CSIR, Current relay 300


30 35 40 45 50 55 60

Start Current . . . . . . . . . . 23.1 Amps 5.8


Coil Resistances Run . . . . 1.41 Ohms 5.6
@ 68°F (20°C) 5.4

Current (A)
Start . . . 7.93 Ohms
5.2
5.0
4.8
*Test Conditions for Performance Specifications
4.6
4.4
4.2
Test Oil . . . . . . . . . . . . . . . . Freol α 22
30 35 40 45 50 55 60
Shell Temp . . . . . . . . . . . . . . 170.0°F / 76.0°C
Condensing Temp . . . . . . . . . 130.0°F / 54.4°C 5,000
Evaporating Temp . . . . . . . . . 45.0°F / 7.2°C
4,500
Capacity (BTU/H)

Ambient Temp . . . . . . . . . . . . 95.0°F / 35.0°C


4,000
Gas Superheat . . . . . . . . . . . 95.0°F / 35.0°C
Liquid Sub-Cooling . . . . . . . . 115.0°F / 46.1°C 3,500

3,000

Electrical Accessories†
2,500

2,000
Overload Protector 30 35 40 45 50 55 60
Nominal Operating Characteristics Evaporating Temperature (°F)

Model Name MSP24ALZ 120°F 130°F 140°F


Manufacturer Texas Instruments
Temperature To . . . . . . . . . . . Open: 248°F ± 9°F / 120°C ± 5°C
Close: 142°F ± 20°F / 61°C ± 11°C 9 – Point Data
Trip Current . . . . . . . . . . . . . . @158°F (70°C) 6.7 Amps ± 7.5%
@77°F (25°C) 17.5 Amps @ 18 sec. max. Evaporating Temp.
Condensing Temp. Rating +30°F +45°F +59°F
Current Relay Model 140°F Btu/h 2,141 3,073 4,196
Nominal Operating Characteristics
Watts 374 448 525
Model Name MM5-D2CH Amps 4.41 5.00 5.65
Manufacturer Matsushita
E.E.R. 5.72 6.86 7.99
Pick Up Current 13.2 max. Amps
Drop Out Current 11.1 max. Amps 130°F Btu/h 2,229 3,175 4,357
Watts 363 429 497
Start Capacitor 80 µF 160 V (min.) Amps 4.32 4.85 5.42
E.E.R. 6.14 7.40 8.77
†Although these accessories are listed by UL/CSA for use with this compressor,
Matsushita assumes no responsibility whatsoever for these or any other components 120°F Btu/h 2,305 3,295 4,500
sourced by the refrigeration system manufacturer from third parties. Watts 347 409 470
Amps 4.21 4.69 5.20
E.E.R. 6.64 8.06 9.57

Panasonic
® Panasonic Industrial Company
Refrigeration Products Department
Tel: 201 - 392 - 4249
Fax: 201 - 392 - 4315 Rev#1-5/9
MATSUSHITA Compressor Single Phase 115 V
MODEL# QA91K22CAU6 (80µF Start Cap.) R-134a 60 Hz

205.1mm (8.07")
165.1mm (6.50")

101.6mm
(4.00")
4 holes
19mm (0.75") DIA
~ C.S.I.R.
131.6mm
(5.18") 54mm 1 2
89mm (2.13")
(3.50")
84mm
(3.50")
3 C

88mm 88mm Discharge


Process or (3.46") (3.46") Tube
Suction Tube
Process or S M
125mm Suction Tube
(4.92") 1 S Compressor
184mm DIA Motor
(7.24") Starting
Capacitor

B
2 M

Current Relay
A

C
F E D

12.2mm (0.48")

Dimensions*

mm inches Tubes Tube O.D. Wall Material


A . . . . . . . . . . . . . . . . . . . . . 208.6 . . . . . . . . . . . . . . . . . . . 8.21 Suction . . . . . . . . . . 0.39 in. / 10 mm 0.035 in. / 0.9 mm Copper
B . . . . . . . . . . . . . . . . . . . . . 92.8 . . . . . . . . . . . . . . . . . . . . 3.65 Process . . . . . . . . . 0.39 in. / 10 mm 0.035 in. / 0.9 mm Copper
C . . . . . . . . . . . . . . . . . . . . . 115.8 . . . . . . . . . . . . . . . . . . . 4.56 Discharge . . . . . . . . 0.33 in. / 8.3 mm 0.035 in. / 0.9 mm Copper
D . . . . . . . . . . . . . . . . . . . . . 77.0 . . . . . . . . . . . . . . . . . . . . 3.03
E . . . . . . . . . . . . . . . . . . . . . 62.2 . . . . . . . . . . . . . . . . . . . . 2.45 U.L. File # . . . . . . . . . SA 4615
F . . . . . . . . . . . . . . . . . . . . . 77.0 . . . . . . . . . . . . . . . . . . . . 3.03 C.S.A. File #’s . . . . . . LR - 34080
* All dimensions are for reference only LR - 36593
LR - 100738

This document sets forth certain operational parameters and conditions for
operation of this product. If this product is operated outside of the parameters General Data Oil Charge . . 250 cc ± 5 cc / 15.3 cu.in. ± 0.3 cu.in.
and conditions stated herein, buyer assumes sole and full responsibility and Net Weight With Oil . . . . . . . . . . . . 21.4 lbs, 9.7 kg
shall indemnify seller with respect to all product failures and all consequences
thereof. Operation of the product outside of the parameters and conditions Approved Oils . . . . . . . . . . . . . . . . . . FREOL α 22
specified herein shall serve to invalidate all seller warranties, if any, with respect Residual Moisture . . . . . . . . . . . . . . . 120 mg max.
to the product. This document is for reference only. For specifications, please
Impurities . . . . . . . . . . . . . . . . . . . . . . 10 mg max.
contact Panasonic’s engineering department.
Displacement . . . . . . . . . . . 9.07 cc. / 0.553 cu. in.

Panasonic
® Panasonic Industrial Company
Refrigeration Products Department
Tel: 201 - 392 - 4249
Fax: 201 - 392 - 4315 Rev#1-5/9

You might also like