INTRODUCTION
Remote control facilitates the operation of regulators around the home or office
operate, a system that would be cheap and affordable, a reliable and easy to
maintain system of remote control and durable system irrespective of usage. It adds
around to operate a fan regulator. The system seeks to develop a system that is cost
effective while not under mining the need for efficiency. The first remote control,
called “lazy bones” was developed in 1950 by Zenith Design and Construction of a
Remote Controlled Fan Regulator. The device was developed quickly, and it was
called “Zenith space command”, the remote went into production in the fall of
1956, becoming the first practical wireless remote control device. Today, remote
and satellite boxes, digital video disc players and home audio players. In year
2000, more than 99 per cent of all TV set and 100 per cent of all VCR and DVD
players sold are equipped with remote controls. The average individual these days
probably picks up a remote control at least once or twice a day. Basically, a remote
1
control works in the following manner. When a button is pressed it completes a
specific connection which produces a signal specific to that button. The transistor
amplifies the signal and sends it to the LED which translates the signal into
infrared light. The sensor on the appliance detects the infrared light and reacts
appropriately. The remote control’s function is to wait for the user to press a key
and then translate that into infrared light signals that are received by the receiving
kHz. Usually, the transmitter part is constructed so that the transmitter oscillator
which drives the infrared transmitter LED can be turned on/off by applying a TTL
receiver side, a photo transistor or photodiode takes up the signals. The approach
used in this work is the modular approach where the overall design was broken
into functional block diagrams, where each block in the diagram represents a
to bring about the ease to operating the various desired home appliances, as to add
around to operate a fan regulator. The system seeks to develop a system that is less
cost implicative while not under mining the need for efficiency, with
2
advancements in modern technology in mind, the design seeks to reduce stress in
operation of the electric fan through working quiet a distance to the regulator.
The aim of this project work is to design and construct a remote control of four
1. To design an electrical circuit for a remote control four speed fan regulator.
3. To study the operation of a four speed remote controlled regulator for a fan
4. To endeavor that the design delivers the best product or the most efficient
The purpose of the project is to ease regulating fan regulator based on the speed
desired by designing and constructing a remote controlled four speed fan regulator
for use both in the home and out-door using a remote control.
3
1.5 SIGNIFICANCE OF THE STUDY
1. The remote control device sends an infra-red beam, which is received by the
infra-red sensor on the regulator and the speed of the fan is increased thereby
individuals.
regulators with the use of the remote controlled method of regulating its
The scope of this project work covers the designing of an operational circuit that is
mechanism and the construction of the design using locally available electrical
4
1.7 LIMITATIONS OF THE STUDY
The limitations that were encountered during the design of the project work
include:
The frequent burn out of the infra – red device due its sensitivity to
temperature.
network.
2. SPEED: The rate at which something (in this case the fan blades) moves or
operates.
5
CHAPTER TWO
LITERATURE REVIEW
Pictorial records show some of the earliest fans date from around 3000 BC and
there is evidence that the Greeks, Etruscans and Romans all used fans as cooling
and ceremonial devices, while Chinese literary sources associate the fan with
Early fans were all of the fixed type, and the folding fan does not appear either in
The first European folding fans were inspired by and copied from prototypes
brought in to Europe by merchant traders and the religious orders that had set up
colonies along the coasts of China and even Japan. These early fans were reserved
for Royalty and the nobility and, as expensive toys; they were regarded as a status
symbol.
In recent times, the electric fan is no longer a “must have” accessory as it used.
terms of regulating ranging from the ceiling fan to the remote controlled or
rechargeable fans. This project work seeks to dive further into the many diverse
6
fan regulator schemes to design and construct an operational and affordable four
speed remote controlled fan regulator for both industrial and domestic use.
control. The inventions of various kind of transistor have made it easier in building
The various components were used in the cause of the design and implementation
Transformer
Power diodes
Capacitor
Resistor
Zener diode
Transistor
Voltage regulator
Infra-red
Fan
7
Decade counter
Relay
Switch
Oscillator
The various values of the used components are as shown in the specification
The remote control device has the task of sending the infra-red signal, which is
received by the infra-red sensor. It’s mode of operation can be better understood
through the circuit diagram. Circuit of remote device At the application of voltage
from the 9v battery or when the single switch is closed, the 4060B oscillator IC,
produce high and low signals on pin 6, which is feed across the base of the NPN
transistor. When the output from the oscillator is high, there is a high voltage
across the base of the NPN transistor, which turns it on. This permits the infrared
the output from the oscillator is low, there is a low voltage across the base of the
NPN transistor, which turns off the switching transistor, resulting in no emission of
any infra-red ray from the infra-red emitting diode. The 4060B oscillator IC
8
The pulse is connected to the base of the switching transistor through a
1kΩresistor. The pulse determines frequency on the infra-red beam, such that it’s
RELAY (CONTACTOR)
where several circuits must be controlled by one signal. The first relays were used
in long distance telegraph circuits as amplifiers: they repeated the signal coming in
from one circuit and re-transmitted it on another circuit. Relays were used
operations. A type of relay that can handle the high power required to directly
control power circuits with no moving parts, instead using a semiconductor device
sometimes multiple operating coils are used to protect electrical circuits from
overload or faults; in modern electric power systems these functions are performed
by the use of digital instruments called protective relays. Because relays are much
more resistant than semiconductors to nuclear radiation, they are widely used in
The use of relays for the logical control of complex switching systems like
Relay and Switching Circuits. Relays can perform the basic operations of Boolean
normally open contacts in parallel. Inversion of a logical input can be done with a
normally closed contact. Relays were used for control of automated systems for
machine tools and production lines. The Ladder programming language is often
used for designing relay logic networks. Relays are used wherever it is necessary
to control a high power or high voltage circuit with a low power circuit. The first
application of relays was in long telegraph systems, where the weak signal
with small, low voltage wiring and pilots switches. Operators can be isolated from
the high voltage circuit. Low power devices such as microprocessors can drive
10
automobile, a starter relay allows the high current of the cranking motor to be
RESISTOR
resistance as a circuit element. Resistors act to reduce current flow, and, at the
same time, act to lower voltage levels within circuits. In electronic circuits,
resistors are used to limit current flow, to adjust signal levels, bias active elements,
and terminate transmission lines among other uses. High-power resistors that can
dissipate many watts of electrical power as heat may be used as part of motor
resistors have resistances that only change slightly with temperature, time or
operating voltage. Variable resistors can be used to adjust circuit elements (such as
and forms. Resistors are also implemented within integrated circuits. The electrical
are manufactured over a range of more than nine orders of magnitude. The nominal
This project work made use of the common emitter configuration (CE) using the
NPN types of transistor, in which input signal is usually applied between the base
and emitter, while the output signal is taken from the collector and emitter circuit.
Where IB is the input current, IC is the collector current, the ratio of the d.c
semiconductor device used to amplify and switch electronic signals and electrical
Because the controlled (output) power can be higher than the controlling (input)
active region, the emitter–base junction is forward biased (electrons and holes
recombine at the junction), and electrons are injected into the base region. Because
the base is narrow, most of these electrons will diffuse into the reverse-biased
(electrons and holes are formed at, and move away from the junction) base–
collector junction and be swept into the collector; perhaps one-hundredth of the
electrons will recombine in the base, which is the dominant mechanism in the base
current. By controlling the number of electrons that can leave the base, the number
12
of electrons entering the collector can be controlled. Collector current is
Infra-red sensor and signal amplifier. The signal from the infra-red transmitter is
sent to an infra-red sensor. The sensor converts the infra-red energy into
corresponding electric current. The four stage NPN transistor amplifiers boost the
intensity of the signal to a reasonable level. The output is fed out to a connected
RC filter. Such that any reasonable distortion is simple is simply removed from the
signal. The relay is designed to switch off for some time after the signal has being
sampled by the sampler. The cutoff technique eliminates any distortion or errors
The fan regulator system works on the principle of sequential counter of the
integrated circuit, such that when the regulating button is pressed, the sequential
switching of the counter I.C regulates a particular regulator speed, this continuous
13
2.6 APPLICATION OF REMOTE CONTROLLED FAN RRGULATOR
1. Remote controlled Fan Regulator is used to control the speed of fan from our
bed or couch.
2. The same circuit finds its use to control the Intensity of light at various
levels.
3. This circuit also finds it use for switching ON and OFF any electronic
circuit.
14
CHAPTER THREE
METHODOLOGY
25V) and a 5V regulator. The relays are supplied by a 12V supply from the
rectifier. And the regulated 5v supply from the 7805 is used for the main circuit.
The full wave rectifier has 4 diodes connected in two cycles which include; the
positive half cycle and the negative half cycle. In the positive half cycles two
15
diodes say D3 and D4 are forward biased and conduct, while the remaining two
diodes D1 and D2 are reverse biased and behave as open circuits. During negative
half cycle, diodes D1 and D2 are forward biased and conduct while D3 and D4 are
reverse biased and behave as open circuits. As shown in the diagram below
showing the bridge rectifier. As we all know that the main function of rectifier is to
convert alternating input supply to D.C. which will be used to charge the battery
16
3.2 DESIGN SPECIFICATION
8 INFRA-RED TSOP1738
13 SWITCH SW
17
3.3 DESIGN MATERIALS AND COST
DESCRIPTION PRICE
4 RESISTOR 20 6 120
5 ZENER DIODE 50 1 50
15 TOTAL 8270.00
18
3.4 BLOCK DIAGRAM
REMOTE
CONTROLLED UNIT
VOLTAGE
TRANSFORMER RECTIFYING UNIT RECEIVING SENSOR
REGULATOR UNIT
Circuit diagram
19
3.6 WORKING PRINCIPLE THE REMOTE FAN REGULATOR
The button feeds the preamplifier such that it sends signals from the remote
controlled unit to the receiver power amplifiers. This amplifies the input signals to
an adequate transmitter line level. In view of the above, one can now say that the
regulation. It usually sends its signal using a small transmitter to a nearby receiver
connected to the system, but it can also use infrared light if the transmitter and
receiver are within sign of each other. The transmitter is responsible for taking in
the signal from the remote control device and transmitting it to the receiver using
is one in which communication is not limited by a cable. It usually sends its signal
system, but it can also use infrared light if the transmitter and receiver are within
sign of each other. The transmitter is responsible for taking in the signal from the
microphone, modulating it, and transmitting it to the receiver using radio waves.
20
3.7 DESIGN CALCULATIONS
Pinout diagram
2 TRIG The OUT pin goes high and a timing interval starts when this
GND.
21
4 RESET A timing interval may be reset by driving this input to GND, but
the timing does not begin again until RESET rises above
6 THR The timing (OUT high) interval ends when the voltage at THR
open).
voltage to the CONTROL VOLTAGE input one can alter the timing characteristics
of the device. In most applications, the CONTROL VOLTAGE input is not used. It
22
Schematic of a 555 in bistable mode
In bistable (Schmitt trigger) mode, the 555 timer acts as a basic flip-flop. The
trigger and reset inputs (pins 2 and 4 respectively on a 555) are held high via
pull-up resistors while the threshold input (pin 6) is simply floating. Thus
transitions the output pin (pin 3) to Vcc (high state). Pulling the reset input to
ground acts as a 'reset' and transitions the output pin to ground (low state). No
23
The output pulse ends when the voltage on the capacitor equals 2/3 of the
supply voltage. The output pulse width can be lengthened or shortened to the
The output pulse width of time t, which is the time it takes to charge C to 2/3 of the
supply voltage.
These specifications apply to the NE555. Other 555 timers can have different
MAXIMUM RATINGS (TA = 25°C unless otherwise noted, common for Q1 and
THERMAL CHARACTERISTICS
24
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings
are stress ratings only. Functional operation above the Recommended Operating
VCEO = 50V
VCBO = 50V
VEBO = 50V
IC = 100mA
PD = VCEIC
PD = 50 × 100mA = 5000Mw
𝑉𝑐𝑐𝑅2
VR2 =
𝑅1+𝑅2
9 𝑋 10 90
VR2 = = = 6.0v
5+10 15
VB – VEE - VBE = 0
VB - IERE - VBE = 0
25
Recall;
IE = IB + IC
IC = (β + 1)IB and,
IC = βIB, where β = 50
𝑉𝐵 − 𝑉𝐵𝐸 6−0.7
IB = = = 0.0113Ω = 104µA.
(β+1)𝐼𝐵 (50+1)1𝐾Ω
VCe - VCC - VC = 0
Where ICRC
VCe = ICRC - VC
𝑉𝑆
note the input voltage of the system is Vin = = approximately rin
𝑟𝑖𝑛
26
CHAPTER FOUR
The fan is powered ‘ON’ and subsequently regulated by the remote control device.
The different four speed level of the fan is regulated through the use of infra – red
control by pressing the switch button which sends signal to the sequential decade
counter which in turn sends signals to the driver unit which initiate the control of
the fan movement. In this design, the remote control fan regulator has only one
button for the control as against having four different buttons, nevertheless, the
button indicates the various level of the speed drive of the fan.
current, resistances and voltage were taken and compared with design values. To
operate the circuit, the switch, is held down while pointing the LED at the receiver.
The aim is to design a remote control that is portable in size and a receiver that
responds only to the infra-red signal transmitted by the remote control. The system
responds favourable and automatically changes the fan speed. The receiver-
4.3 PROBLEMS/TROUBLESHOOTING
The problem associated with the design is in the area of the proximity to operation
of the device, and since the device uses infra – red signal; its line of sight should
For maximum use of the designed system, the sequential counter device should be
very effective in infra-red communication, the line of sight of the infra-red device
and its receiver should through. The 555 timer circuit should be a very high
The operator should know that this is a prototype of a remote controlled fan
28
CHAPTER FIVE
5.1 RECOMMENDATION
The remote controlled fan regulator was developed using infra-red. This posed its
difficulties and gave certain limitation i.e. the infra-red sensor could not filter out
surrounding bright light. Engineers trying to improve on this should work towards
perfectly filtering out bright light so that only the infra-red rays are incident on the
infra-red sensor. The power supply could be improved, where a step-down would
not be used, thereby reducing the entire size of the project. Similarly, micro
soldering could also be used in order to further reduce the size of the equipment.
5.2 CONCLUSION
product or the most efficient services at the lowest cost to the end user. The system
has being tested and was found to meet the expected results. The aim of this work
was to design and construct a remote control for a fan regulator, and the system has
thus accomplished that. The remote control device sends an infra-red beam, which
is received by the infra-red sensor on the regulator, the display on the regulator
indicates a change in fan speed and the fan also increases in speed. The same
circuit finds its use in many more applications. By this the intensity of light can be
29
controlled using a remote. The intensity of light can be controlled in five levels
from off position to maximum intensity possible. So it finds use as a night lamp by
keeping the intensity of lamp in low level. Our normal T.V remote can be used for
all these purposes. So it is very useful or a real help to old age and sick people,
since they can control the speed from the place where they are sitting. We feel that
our product serves something good to this world and we like to present it before
30
REFERENCES
http://www.howstuffworks.com.
Publishing, 1986.
4. Theraja B.L., Theraja A.K., A text book of electrical technology, Ed. 21st
5. Horowitz P., Hill W., The art of Electronics, 2nd Ed., Cambridge University
31